SU-6000 User manual.indd
Contents
1. IC Vendor SAMSUNG Part Number K9F1208UI0C TS48 File Name itest bin Quantity Unlimited e 6 Program Read Verify Erase Group Define 3 oad Group Define File 4 4 Using Group Define Group Define File Name Fracedure Hsub000 SU 6000_0731 DateBase Groupigroup512 def 5 7 D Select device D Load the file that you are going to program into the device The file must include all data of Group Program 6 Select Group Define Mark Using Group Define QO Press Load Group Define File then select group512 def QO Select Program then mark Scan Bad Block Press OK to execute programming group512 def is set according to the format of current Group Program If there is a new Setting user must load another Group Define File Please operate according to the procedures above after starting the software 17 SU 6000 User s Manual B How do create a Group Define file 1 First use the software which can be edited as binary and open the Group Define file In SU 6000 software directory database group has a pre defined file group64M def for reference 2 Enter edit mode to start editing P Dump Edit T 50 4 j o 1 offo 00 oo oo oo oo loo OO BF oploo oo Fs o3 00 oo J oo0020 01 of 00 oo Ico ocloo 00 BF oF oo oo 71 ol o0 oo J 00003 ollo o0 oo oo co oF o0 OO FF oF loo oo o2 ooloo oo I 00004 O FE FE FF FF FF FF FF FF FF FF FF FF
2. FF FF FF FF 0000 S 0 FF FE FF FF FF FF FF FF FF FF FF FF FF FF FF FF OO006 0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF OOd0 7 O FE FE FF FF FF FF FF FF FF FF FF FF FF FF FF FF OO0008 0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF OO00 9 0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF OO00 40 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF 0000 80 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF OO00C 0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF 000D DO FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF 0000 EOD FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF O000F 0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF From the beginning of 000010 each 16 byte as a group D The start block of this group 3 The end block of this group Need to program number of this group 18 SU 6000 User s Manual 3 As below picture define 3 groups Me Dump Edit BF OD OU E HE He Ne GS e E e aS E Ne E Me EE ME Ee E e as E NE DEE Me OEE ME Bee ME Re aS BEE M DEE gad 3 dR SSS MEE M OEE D daa Se aR SE aS aaa 599 9 995 494 qaqa GS 9G ag aS qed gga gg ag as qaqa 99 9 9g Se als Pea g ga SaaS aS BEE ME DEE O dR 3 SRS aS HE Ne 99 9 99 5 494 qaqa gq Gag ae aS qed dag E e as qaqa g dad GS aS Pea g dad DEE DE REE aS group from the block 0 till the block OxODBF the total number of programming block for Ox03F5 group from the block OxODCO till the block OxOFBF the total number of program
3. setup before programming Ii 30 6000 GANG PROGRAMMER Project Name Project IC Vendor SAMSUNG Fart Number JKSGRGOBUOM TS43 File Name Data From Buffer Quanity Unlimited 1 Programm Read verify Erase Group Define W Erase gt IY Progam gt V Verify Block Option Scan Bad Block Procedure Ignore Bad Block Status 12 SU 6000 User s Manual 2 Press Select Device button to choose the vendor and part number Then press OK to go back the previous Order Manager dialog box Manufacturer Type Number HYNIX HAUS LAL TS 48 HY2TUFOUEIG2A T S43 HYSTUFUR2G2A T S48 HY2UFUS4G 2h Tos AYA UG0ssG 5M TSAS HYAA UH 4 2h TS 43 HY27US08121 A TS4s HYAA U50121 B TS 4a HY2TUS081 21M TS AY2TUS0e261 A To4e AY2TUSOS28 MTS ig PIN 4 VOC 3 30 VCCP 3 30 VPP 3 30 SIZE d4hl sbits Note SU 68 NAND TSOP4s Kor ff ox 3 Press Select File and select the file route of programming and beware the file content You have to click File Include Spare Area Data option if the file contains spare area data Make confirmation again then press OK to go back to Order Manager box File D SU 6000itest bin z Pe mse Format mource elect w Auto Detect C MS DOS fir exe Start Address ooooo00000 End Address 0000041FFF f MS DOS fr com C Binary Machine Code Destination Select i Intel HES C Motorola HEX sta
4. unit Start button Execute programming Zero the counter Information column 25 SU 6000 User s Manual Chapter 5 Problems solution 1 Unable to find the programmer Please make sure the power is on Does USB cable connect properly Dose the driver install correctly Confirm that if the USB port is 2 0 High Speed interface Unable to detect IC and proceed programming Please check Does the IC put properly Is it in right insertion way Are the connected pins clean and ordered Please use brand new IC for programming do not use the used ones in case shorten the adapter s life Is the adapter s part number correct Is the socket out of usable period 3 Exceed limited using frequency Adapters are expendables please purchase a new one if the original adapter is unable to use Appear abnormal operation situations Shut down the programmer and software To try again by re execute the software and turn on the power of programmer Microsoft operation system after Win 2000 XP and later needs to have administrator privilege to install driver or other application 26
5. SU 6000 User s Manual J A S FSF RDB A D LEAP ELECTRONIC CO LTD SU 6000 User s Manual Contents Chapter 1 SU 6000 Hardware Installation cccccceee 3 Chapter 2 SU 6000 Software Installation ceeeceeeeeeees 8 Chapter 3 SU 6000 Operation Manual For NAND FLASH cccccccccececeeeeeeeeeeeeeseeeeeeeeeeeeaeeeens 12 Chapter 4 SU 6000 Operation Manual For NOR SPI FLASH ccccccccceceseeeeeeeeeeeeseeeeeeeeeaeeenens 21 SU 6000 User s Manual Chapter 1 SU 6000 Hardware Installation 1 Surface 1 SU 6000 s front Please check reed If reed is a serious distortion and deformation it should be adjusted 2 SU 6000 s side SU 6000 User s Manual 3 How to connect cables to SU 6000 1 Ground wire Use the wire for the ground 2 ID knob It should be set a different ID number when connect multiple SU 6000 in the same PC If so the PC software will be able to correctly identify the different SU 6000 3 USB A USB cable A to B connector for access to PC 4 AC power cord 110V AC 240V AC power 5 Power turn on O turn off 2 Setup Adaptors 1 Align the adaptors on the fixed points of the connectors SU 6000 User s Manual 2 Put the the adaptors gently and slight move the them Make sure the PCB and the fixed points have been wedged Then screw them SU 6K SFLASH SOP amp 150 I ee eE ei ee a m m
6. T a _ l ot a on a 3 Four screws should be locked in a clockwise direction slightly first then lock them tight These actions can avoid the dis average pressure between the PCB and the reed which will cause the damage on the reeds ues SU 6K SFLASH oa SOP8 150 Me ae as Frrparcal TU nme pr raie i i Ce G NA va SU 6000 User s Manual 4 Just screw by hand will be fine It not necessary to use tools such as screwdriver Screw too tight will cause damage to the connector Ir DERE aea a C 5 After all of the adaptors locked the SU 6000 hardware setting has completed m SU 6000 SU 6000 User s Manual 3 Power SU 6000 on 1 Power on the power switch 2 After power on the LED will keep bright state 3 Then run the PC software and start programming SU 6000 User s Manual Chapter 2 SU 6000 Software Installation 1 SU 6000 System Requirement 2 3 Memory 1GB 2GB and above 4 Hard Disk over 200M free space Depend on IC Size 5 2 SU 6000 Driver Installation 1 Connect the power cord and USB cable with SU 6000 At the first time you turn the power on a message as below picture should appear on the right bottom of your screen 3 i Found New Hardware gt EEEa fang Programmer a2 PM SU 6000 User s Manual 2 Await add new hardware dialog box to appear the
7. ck 15 Binck quantity 06 Bize Fii Bytes DOAMT 16 58 37 Completed Fue 1 Feil 8 Total 1 7 Take the programmed IC and put another blank one click Start to continue programming until complete all the scheduled work 15 SU 6000 User s Manual 8 Software Icon Instruction I SU 6000 GANG PROGRAMMER O 2 3 a h m H oF es a Q 9 0 Ute Order Project Device File Sum Function Process ae Erase Scan Bad Block Program Verify Projecti HYNIX HY27US08121M TS48 pp SU 6000 001_BIN 00150C59F5 Process Block 160 GANG PROGRAMMER Copyright Cc LEAP ELECTRONIC CO LTD www eep com tw Information Times 2008 03 17 17 43 00 gt Return to Order Manager Pass quantity D Fail quantity 3 Total quantity O Adaptor status O Enable the adaptor marked O One unit Start Button Execute programming Function key Program Read Verify Erase Description of function key Back to Order Manager window 10 Total pass quantity of 4 sites 11 Total fail quantity of 4 sites 2 Total quantity of 4 sites 13 Start button One multiple unit execute programming 1 4 Zero the counter 15 Information Column 16 SU 6000 User s Manual 9 Specific Function of programming Nand Flash A The Way to Process Group Program Please refer to the below picture to load define file Froject Name Project sl
8. complete all the scheduled work 24 SU 6000 User s Manual 8 Software Icon Instruction IP SU 6000 GANG PROGRAMMER 2 2K 9 aE Order 0 0 FAIL Device xic MX29L VE40BTT TSOP48 20mm File HATE STFILE mx29h640_080620 1 B1N Sum 005A98AD7A GANG PROGRAMMER PASS jhi 00 00 Copyright C LEAP ELECTRONIC CO am oe 00 Information Times Status 2008 09 12 17 05 36 Device gt MXIC MX29L V640BTT TSOP48 20mm N 2008 09 12 17 05 36 File gt H TESTFILE mx29lv640_080820 1 BIN 2008 09 12 17 05 36 IC sum gt OO5A98AD 7A 2008 09 12 17 05 36 Operation Mode 2008 09 12 17 05 36 Procedure setting gt Blank Check Erase gt Blank Check gt Program Verify 2008 09 12 17 05 44 Programmer unit 1 gt Start Blank check Erase 2008 09 12 17 06 21 Programmer unit 1 gt Start Blank check 2008 09 12 17 06 23 Programmer unit 1 gt Start Program Verify 2008 09 12 17 06 53 Programmer unit 1 finished 69 641 Sec Pass quantity Fail quantity Total quantity Adaptor status Enable the adaptor marked QO One unit Start button Execute programming G Function key Program Read Verify Erase Blank Check Description of function key Back to Order Manager window Total pass quantity of 4 sites Total fail quantity of 4 sites Total quantity of 4 sites One Multiple
9. e the driver to install Chooze this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware 5 When the below dialog box appears please click Continue Anyway Found New Hardware Wizard Please wait while the wizard installs the software Hardware Installation The software you are installing for this hardware SU 6000 Gang Programmer has not passed Windows Logo testing to yvenfy its compatibility with Windows lt P Tell me why this testing ts important Continuing pour installation of this software may impair or destabilize the corect operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway f 10 SU 6000 User s Manual 6 Click the Finish button to complete the driver of SU 6000 Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for SU 6000 Gang Programmer Click Finish to cloze the wizard Finish Cancel 11 SU 6000 User s Manual Chapter 3 SU 6000 Operation Manual For NAND FLASH 1 Open the file folder where SU 6000 software located execute program SU 6000 nana then enter Order Manager dialog box to proceed the
10. gnam erh BEC HPAL WATE F THD DEH Fik HATESTA LE teyin B BiH Pi ITRE C pem t DADA 23 SU 6000 User s Manual 6 Then select the order in Function column the default setting is program Put the IC properly then click Start button and wait represents program complete The result will show on the screen and the LED on programmer will also show the result by different light signals Green light Pass Red light Fail Order Device MXIC MX29LV640BTT TSOP4B 20mm File HATESTFILE mx291640_080820 1 BIN Sum 005A98AD7A A p GANG PROGRAMMER PASS i 00 00 opyright C LEAP ELECTRONIC CO LTD ee mea com ae N o 0 00 wom 1 Information Status 2008 09 12 17 05 36 Device gt MXIC MX29LY640BTT TSOP48 20mm 2008709712 17 05 36 File gt H TESTFILE mx29lv640_080820 1 BIN 2008 09 12 17 05 36 IC sum gt 005A98AD7A 2008 09 12 17 05 36 Operation Mode 2008 09 12 17 05 36 Procedure setting gt Blank Check Erase gt Blank Check gt Program Verify 2008 09 12 17 05 44 Programmer unit 1 gt Start Blank check Erase 2008 09 12 17 06 21 Programmer unit 1 gt Start Blank check 2008 09 12 17 06 23 Programmer unit 1 gt Start Program Verify 2008 09 12 17 06 53 Programmer unit 1 finished 69 641 Sec 7 Take the programmed IC and put another blank one click Start to continue programming until
11. he previous Order Manager dialog box 21 SU 6000 User s Manual Manufacturer Type Number Package MI E Mx25LV6408 TT IT SOP48 20mm PMC CARA SAMSUNG hae 9LB40DBT SEIKO o MX29LVe40D7T SPANSION M29 S00CBT SE g Mx29Lv800CTT PIN 48 Man Code Ox00C2 SIZE 64M bits Note SU 6EK NOR TSOP48 Al Mee9lTbOC TT bises ae200BT Mee4l ae200T T Mieg b40BBT TSOP48 e Ommi R my Dev Code Oe22C9 Type Memory 3 Press the Select file and select the file route of programming and beware the file content then press OK to go back to Order Manager box Ii SU 6000 GANG PROGRAMMER H ATESTFHILE m29640_080820 1 BIN File Format Auto Detect E SS Tie ce C MS DOS fn com C Binary Machine Code C Intel HEX Motorola HEX Tektronix HEX sec Fill Unused By OxFF 7 OK x Cancel o0 I J C Other FF 22 SU 6000 User s Manual 4 Confirm the program procedure as follow Blank Check Erase if the device is in blank will not process the Erase function gt Blank Check gt Program gt Verify Normal Program Read verity Erase M BlankCheck gt W Erase Frocedure gt iV Blank Check ma A eer gt V Verity Normal gt Verity YeciMag gt I Verify YeciMin gt Protect 5 After you complete above procedures click OK to enter the program box Carder Device WEE MOLMEDBTT TSOP Gaim Flank Check Erase Blank Check Pro
12. ming block for 0x01771 group from the block Ox0FCO till the block OxOFFF the total number of programming block for 0x0002 4 Notes Group definition of the size can not exceed the number of IC block and each group can not overlap each other Need to have a corresponding programming image file includes spare area data and blank block 19 SU 6000 User s Manual C MLC Nand Flash Error Bit check function 1 After programming is completed if the software shows a PASS message it means there is the corresponding adaptor of the IC have a page does not exceed 4 bit error bit data wiew bad block TOTAL J 3 The software shows error bit record as the following picture TX1 There are 3 error pages each page has an error bit TX2 No data TX3 No data TX4 No error bit 20 SU 6000 User s Manual Chapter 4 SU 6000 Operation Manual For NOR SPI FLASH 1 Execute program SU 6000 then enter Order Manager dialog box to proceed the setup before programming If S0 6000 GANG PROGRAMMER j is IE Vendor AMIS Fart Number A25L080 Packaqe SOP8 1 50 File Mame Program Read Verity Erase W Blank Check gt Iv Erase Frocedure i Blank Check i Program gt i Verite Normal gt Verify YcciMag gt D verity Ycciblin Erotect 2 Press Select Device button to choose the vendor part number and packing Then press OK to go back t
13. n choose the option No not this time to start installation Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for curent and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows conmect to Windows Update to search for sothware ves this time only es now and every tine connect a device Click Hest to continue 3 Then click the option of Install from a list or specific location Advanced Found New Hardware Wizard This wizard helps you install software for Gang Programmer f If pour hardware came with an installation CD k lt o Hoppy disk insert it now what do wou want the wizard to da Install the software automatically Recommended Click Hest to continue SU 6000 User s Manual 4 Choose the file route of driver Found New Hardware Wizard Please choose your search and installation options Search for the best driver in these locations Use the check boses below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media flappy CO ROM Remember to Choose the installation route alek ihe anim Include this location in the search CA O Don t search will choos
14. rt Address oooooo0000 C Tektronix HEX Fill unused with FF so M File Include Spare Area Data 13 SU 6000 User s Manual 4 Confirm the program procedure Scan Bad Block means to scan bad block before programming Ignore Bad Block means to program without a bad block check Please select Scan Bad Block in common circumstance Program Read Verify Erase Group Define W Erase F Program Verify Block Option Scan Bad Block Procedure w Ignore Bad Block 5 After you complete above procedures click OK to enter the program box GANG PROGRAMMER z am ee See hae E DAF Ue a TA mew fap cor fe WHIT IT A gt Propri Fama Project 14 SU 6000 User s Manual 6 Then select the order in Function column the default setting is program Put the IC properly then click Start button and wait the BEE sound which represents program complete The result will show on the screen and the LED on programmer will also show the result by different light signals Green light Pass Red light Fail res ass i E meena meek HO wan ATE j a ee Erara ican Had Bleck Popa Vey GA NG PROGRA MM ER ET EE et iiih nae nite iit eee ap com fa Ppp EARI S ta comes Exum fren Bed Binck Frogeom Tardy Precans IC px i THIT 16 56 29 Ercag Lli Chip Scan bad black DUNT 16 58 36 Programing Terdyag Stari Hiec ft Ead Bla