Home
        Assembly and Service Manual Barrel Coupling
         Contents
1.    Barrel Coupling  m TS C HA N BAWG007 GBR 0  Assembly and Service Manual    1 INITIAL CONSIDERATIONS     The TSCHAN barrel coupling is supplied as a whole unit  ready to be mounted  but not provided with lubricant  Therefore  before it  is put into service it must be lubricated in the required quantity with the appropriate lubricant  as indicated in chapter 4  table 3      In case it is necessary to dismantle the coupling  i e  for the machining of a pilot bored hub or for the shrink fit setting up  it is very  important to make sure that when assembling it again the hub and the sleeve flange pair off without taking place a possible mixture  between different unities and it will also have to be done in the same relative position at is was supplied  This is achieved by  making coincide the marked tooth of the hub with the corresponding marked tooth of the sleeve flange   reference fig  1 and 2       The bearing support of the drum at the opposite side of the coupling must absorb the axial forces generated during the service  and must convey them to the structure  The axial component of any structural distortion must not exceed the maximum acceptable  axial displacement for the coupling indicated on table no  1      Fixing screws for the assembly of the coupling to the drum and the securing of covers  must have a minimum 8 8 quality  The  tightening torque of these screws will have to be in accordance with the said quality and also  with the material of the covers and    of t
2. 57   0 65   0 72   09   1 0   13   20    Table no  3       Greases   20   C    80  C    BPEnergreaseLS EP2   BP    Table no  4       TK gb 05 00 doc   page 3 of 4      Tschan GmbH Zweibrucker Stra  e 104 D 66538 Neunkirchen   Saar Postfach 2166 D 66521 Neunkirchen   Saar       5 MAINTENANCE    LUBRICATION PERIODICITY   Depending on the operating conditions the lubricant must be completly renewed every 2000 up to 3000 hours of operation and as a  minimum  once a year    For ist renewal  feed the lubricant through the inlet  ejecting the used lubricant through the overflow hole  When new lubricant    starts being ejected out of this overflow hole it will mean that the operation has been completed     PERIODICAL INSPECTIONS   At least once a year the following checkings must be carried out      Tightening of all the screws up to the recommend values and replacement of the damaged ones      Internal wear of the teeth  The position of the mark over the pointer in relation to the marks over the hub   fig  5   will be an  indicator of the state of the flanks wear  When the equipment is new  the pointer mark is centered  case a   When it reaches the  limit  case b  the whole coupling has to be replaced    Table no  5 shows the maximum permissible wear values     m 2     for applications which imply one only sense of loading  ty pical  case of the hoisting in cranes   With applications of reversible loading sense  the amplitude between the marks must be divided by  2  Unless it is exp
3. al position is indicated by the coincidence of the mark at the  pointer with the mark of the hub  fig  3   At the position the setting of the opposite bearing support of the drum to the base is  defined    Afterwards  the angle alignment is checked by measuring the gap    X      fig  4  at four points with a separation of 90   by using a  reference ruler  As an indication  the following maximum difference between the 4 measurements to the height of the external part  of the sleeve flange can be considered as acceptable     0 3 mm for sizes  lt  TK 600    0 6 mm for sizes  gt  TK 1000    External cover    Pointer    Coie  Hare    Axial adjustment marks       fig  3 fig  4    4 LUBRICATION    Once the setting up has been done and before the putting into service  the internal chamber has to be filled with lubricant EP2   Extreme Pressure additive and consistency NLGI 2   The inlet at the external cover is suitable for placing a tubular extension up to  the external part of the drum  making access easier  In practice  lubricant must be fed until it comes out of the oil overflow hole at  the opposite part of the hub  As an indication  Table no  3 shows the approximate amount depending on the different sizes    Table no  4 shows certain references of appropriate lubricants for temperatures of  20 and up to 80  C  Please ask for advice if    temperatures are out of that range     160   200   300   400   600   1000   1500 3400   4200   6200  0 10   0 12 0 17   0 19   0 23   0 45   0 
4. ft      Place the external cover together with its joint and the retainer ring over the shaft  Make sure that the space between the cover  and the reducer is sufficient to house the fixing screws  If it was not so  the screws have to be previously housed in the cover      Heat the hub up to the appropriate temperature for its mounting  Whatever method of heating is used  it must be progressive along  the whole surface  preventing any localized heating spots  As an indication  a maximum temperature of 200  C is usually enough  for this operation      Mount the hub on the shaft until reaching a reference mark previously set or until the hub face matches the shaft end  At this  stage it is crucial to avoid any contact of the hot hub with the seal  Before continuing with the procedure  wait until the hub cools  down and reaches room temperature      Set up the sleeve flange over the hub  checking that the matching and the position reference of these ones is the correct one    fig  2       House the barrels in their cavities and place the external retainer ring in its channel      Fix the external cover making the pointer coincide with the marks over the hub       Check the free axial displacement of the sleeve flange        fig  2    TK gb 05 00 doc   page 2 of 4      Tschan GmbH Zweibrucker Stra  e 104 D 66538 Neunkirchen   Saar Postfach 2166 D 66521 Neunkirchen   Saar       3 AXIAL ADJUSTEMENT AND ALIGNMENT    Once the coupling has been fixed to the drum flange  its correct axi
5. he drum flange  See values on table no  2     Hub  Sleeve flange  Barrel  External cover  Pointer  Internal cover  Seal  Retaining ring  Carrier face    Wear marks    Axial adjustment mark    Assembly mark    Lubricant filler    Overflow hole    Extractor hole    Fixing screw       o N O 0 PE eS    Max  axial displacement    100   130   160   200   300   400   600   1000   1500   2600   3400   4200  Tamm 3 3 4 4 4f4 4 4l4 s6_       Table no  1      Torque  Nm _   26   50   90   215   420   725      Table no  2       TK gb 05 00 doc   page 1 of 4     Tschan GmbH Zweibrucker Stra  e 104 D 66538 Neunkirchen   Saar Postfach 2166 D 66521 Neunkirchen   Saar       2 SETTING UP ON THE REDUCER SHAFT    HUB SHAFT CONNECTIONS BY MEANS OF KEYS  SPLINES  ETC     Clean the surfaces of the hub bore and the shaft     Pre heat the whole coupling by putting it into a bath of hot oil at a temperature which does not exceed 80  C so that the seals are  not damaged  The oil of bath must not attack those components manufactured on a nitrile base      Mount the hub on the shaft avoiding to bump it and applying force only to hub item 1       Check the free axial displacement of the sleeve flange     HUB SHAFT CONNECTION BY MEANS OF INTERFERENCE WITHOUT KEYS   In this case it is necessary to separate the hub from the rest of the coupling      Unfasten and take away the external cover as well as the sleeve flange  the external retainer ring and the barrels      Clean the surfaces of the hub and the sha
6. ressly asked for  couplings are standardly supplied with the marks according to the aforementioned table and  therefore  it is advisable to modify them  if the application requires so  in order to correctly asses the wear evolution      Axial adjustement According to fig  2  If deviation was close to the maximum acceptable value on table no  1  the seat position  of the support bearing must be readjusted       Seals control  If any deterioration appears on the sealing lips  these must be replaced     Pointer    Wear marks       fig  5a fig  5b  Between marks O K  Wear limit    Wear control    O o Wearcontroh OS S S S S S S OSOS  Sze  25   50   75   100  130  160  200  300  400   600   1000   1500   2600   3400   4200   6200         eae eee eae ee ae ee ee ee    Table no  5    TK gb 05 00 doc   page 4 of 4      Tschan GmbH Zweibrucker Stra  e 104 D 66538 Neunkirchen   Saar Postfach 2166 D 66521 Neunkirchen   Saar       
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Cours  S MANUAL DE INSTRUCCIONES  Utilisation de l`enregistreur à carte mémoire Préparation  Philips SDW1422 3 conductor 75 ft Rotor wire    User Manual - Justec International Technology Inc.  AirEdit 03.04.01 User manual  2.Installare n    Garmin PRO 70 Owner's Manual    Copyright © All rights reserved. 