Home

CR10 v2 user's guide

image

Contents

1.
2. 27 V LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 EN Cone wm A BSB ELECTRONICS Company z E 1 SAFETY INSTRU CHELON 1 Safety instruction Please observe the following instructions The router must be used in compliance with all applicable international and national laws and in compliance with any special restrictions regulating the utilization of the router in prescribed applications and environments To prevent possible injury to health and damage to appliances and to ensure that all the relevant provisions have been complied with use only the original accessories Unauthorised modifications or utilization of accessories that have not been approved may result in damage to the router and in a breach of applicable regulations Unautho rized modifications or utilization of accessories that have not been approved may result in the termination of the validity of the guarantee The router can not be opened Before handling of the SIM card turn off the router and disconnect it from power supply Caution The SIM card could be swallowed by small children It must not be exceeded by the maximum voltage 30 V DC power connector on the router Do not expose the router to extreme ambient conditions Protect the router against dust moisture and high temperature The router should not be used at petrol sta
3. Transmit power Supported bands LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de Table 14 Technical parameters of module 26 infoolucom de O E e UO E z z 19 06 15 EN Cone wm A BSB ELECTHONICS Company o r2 TECHNICAL PARAMETERS 7 3 Technical parameters of processor 32b ARM mikroprocesor Memory 512 Mb DDR SDRAM 128 Mb FLASH 1 Mo MRAM Interface Serial interface RS232 Ethernet interface 10 100 Mbit s USB 2 0 interface Table 15 Technical parameters of processor 7 4 Technical parameters I O port 32b ARM mikroprocesor Input Output Binary input Reed contact with trigger level 1 3 up to 1 4 V Binary output 100 MA max 30 V Table 16 Technical parameters I O port 7 5 Technical parameters of expansion port Technical parameters of the expansion ports are specified in separate manuals for expan sion poris info lucom de O E e UO E z z LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de 19 06 15 Wu Cone um A B amp B ELECTRONICS Company 8 RECOMMENDED LITERATURE 8 Recommended literature 1 2 3 4 5 6 7 8 9 10 11 12 13 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de Conel Conel Conel Conel Conel Conel Conel Conel Conel
4. Data flow direction 1 5 V Positive pole of 5 V DC supply voltage 2 USB data USB data signal negative pole Input Output 3 USB data USB data signal positive pole Input Output 4 GND Negative pole of DC supply voltage Table 10 Connection of USB connector Figure 32 USB connector 20 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone um A BSB ELECTRONICS Company 5 ROUTER DISSIICIN Example of connecting devices with serial interface to the USB Transmitter USB RS232 nS Figure 33 Connection PLC to the router Example of connecting of USB flash disk to the USB Flash disc Figure 34 Connection flash memory to the router 5 9 9 I O Port Panel socket 3pin Pin Signal mark Description DEE 1 BINO Binary input Input 2 GND Signalova zem 3 OUTO Binary output Output Table 11 Connection of I O port O la a 1 O Figure 35 I O connector 21 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone wm A BS ELECO eae 5 ROUTER DESIGN The user interface I O is for processing of binary input signal and to control settings of binary output signal Binary output is not switched to ground in the default confi
5. Telnet 25 7 Technical parameters 26 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone wm A B amp B ELECTRONICS Company q 7 1 7 2 7 3 7 4 As Technical parameters of router Technical parameters of module Technical parameters of processor Technical parameters I O port 2 2 soso a Technical parameters of expansion port 8 Recommended literature 9 Possible problems 10 FAQ 11 Customers support CONTENTS 29 30 32 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de QU Ko e O e e Gan E www lucom de 19 06 15 Wu Cone um A BSB ELECTRONICS Company LIST OF FIG U RES List of Figures WO JD OI BON C0 CO CO CO CO CO CO CO CO CO rO roO lO lO lO lO lO lO OOo O cO C SOO FOI DE OVO Y JODO FR VIV HY OVO NODO HF VOI LO Contents of package oso a a 4 Front panel CRIOV2B sss oseo 5 Front panel CRI0v2F soo os soso 5 Front panel CR10 v2B SL 1 es 5 Front panel CR10v2F SL aaa sss so 5 Label CR10V2B 1 a 6 LADE GRINV2ZBOL ssesssassecksa sn NEOS de
6. iss bee eke ee kusas ox uga vu 5 5 2 Delivery identification a sos rrr 6 5 3 Version of firmware module a 7 5 4 Ordering codes 1 ee soso rns 8 5 4 1 Basic version 2 a 8 542 PUIVEISION lt 42 ce2 2 84 ch 4444 OR ER RGE E OR OE wee A 8 5 5 Basic dimensions of plastic box 9 5 6 Basic dimensions of metal box 9 5 7 Mechanical dimensions and mounting recommendatlions 10 5 8 Removing from the DIN rail 12 5 9 Description of the front panel 13 5 9 1 Status indication 14 5 9 2 PowerconneciorPWR a 15 5 9 3 Antenna connector ANT DIV alternatively WIFI or WMBUS 16 5 9 4 SIM card reader cen 17 53 EIOS DOE eu au as e eden Se a ma AAA 1 D SD POKI gus csegss uses Esse ans eoq 44 95 95 19 Sof PORT acarreo s fSu ras seas esse sda gu ke 19 o USBDFPOJE 2 334 x33 CROR UP uy vere pus usage kes SEE usu 20 D99 IPO za exsu kerran sees hee een ee hee ee ee eee Be 21 dlU I sa Can SEG Rae Eee E E DC EE kus 23 6 First use 24 6 1 Connecting the router before first use 24 Due Old a our sois GS EESE reS REFREN 25 bo Vou riu aoe sav 8 EFA SGESE SY UYVA EB SOE RSO SE GU 25 6 3 1 Configuration Overwebbrowser 25 6 3 2 Configuration over
7. router connection 18 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de V T O O 5 O A www lucom de 19 06 15 Wu Cone wm ic 5 ROUTER Di IN 5 9 6 PORTI The PORT1 is equipped on customer s request with one of the offered expansion ports e RS232 e MBUS e RS485 422 e ONT e ETHERNET e SWITCH together with PORT2 Description and examples of expansion ports connection can be found in user s guide for corresponding expansion port PORT1 cable plug into the RJ45 connector labeled as PORTI see figure below Figure 30 PORT1 cable connection 5 9 7 PORT2 The PORT2 is equipped on customer s request with one of the offered expansion ports e RS232 e SWITCH together with PORT1 e RS485 422 e WIFI e MBUS e WMBUS e SDH PORT2 is available only in the Full version of the router Description and examples of expansion ports connection can be found in user s guide for corresponding expansion port 19 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone um A BSB ELECTRONICS Company 5 ROUTER DISSIICIN PORT2 cable plug into the RJ45 connector labeled as PORTI see figure below Figure 31 PORT2 cable connection 5 9 8 USB Port Panel socket USB A Pin Signal mark POT
8. selected by the customer For Port are available Ethernet port 10 100 serial interface ports RS232 RS485 RS422 MBUS or inputs outputs I O CNT Port2 may be equipped with serial interfaces RS232 RS485 RS422 MBUS wireless interfaces WIFI WMBUS SDH expan sion port or inputs outputs I O CNT Both of ports can be fitted with internal switch SWITCH This 3G wireless router is supplied either in a plastic or metal casing based on the require ments of the customer Configuration is done via web interface protected by password The 3G CDMA router sup ports creation of VPN tunnels using technologies IPsec OpenVPN and L2TP to ensure safe communication Web interface provides detail statistics about the 3G router activities signal strength detailed log etc Cellular router supports functions DHCP NAT NAT T DynDNS NTP VRRP control by SMS and many other functions Other diagnostic functions ensuring continuous communication include automatic inspec tion of PPP connection offering an automatic restart feature in case of connection losses or hardware watchdog which monitors the status of the router With the help of a special window start up script window you may insert Linux scripts for various actions For some ap plications the key option to create several different configurations for one 3G wireless router the so called profiles maximum of 4 and the option to switch between them for example via SMS binary input status et
9. 460 20 www lucom de info lucom de O he O Q z z 19 06 15 EN Cone wm A BSB ELECTRONICS Company 5 ROUTER DESIGN 5 9 Description of the front panel On the front panel is located PWR 2 pin Connector for the power supply adapter ETH RJ45 Connector for connection into the local computer network PORT 1 RJ45 Connector for expansion port RS232 RS458 422 MBUS ETHERNET CNT or SWITCH PORT2 RJ45 Connector for expansion port RS232 RS485 422 MBUS SWITCH WIFI WMBUS or SDH only FULL version ANT SMA Connector for main antenna DIV SMA Connector for diversity antenna WIFI R SMA Connector for WIFI antenna Only when router is equipped with an expansion port WIFI WMBUS SMA Connector for WMBUS antenna Only when it is equipped with an expansion port WMBUS USB USB A Host Connector for connection of USB devices to the router Sup ports devices with PL 2303 and FTDI USB RS232 converters I O 3 pin Connector for connection of the binary input and output SIM1 Holder for the first SIM card SIM2 Holder for the second SIM card only FULL version Table 6 Front panel description O olv GKIU V2 O OUT IN USR SIM2SIM1 WAN DAT PWR RST O O info lucom de cae AE AE d cs 5 Outl In LI pos E PORTO PORTI ETH Figure 20 Front panel CR10 v2F SL O E e UO E z z 13 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 4
10. 59 460 10 Fax 09127 59 460 20 www lucom de 19 06 15 EN Cone wm A BSB ELECTRONICS Company om 5 ROUTER DIS Cin 5 4 Ordering codes O Order codes are given for the Polish operator Orange Another operator can be selected by changing two digits according to Table 3 Version of firmware module on page 7 5 4 1 Basic version Version without expansion port CR10 v2B 01 set Version with Ethernet expansion port CR10 v2B 01 ETH set Version with RS232 expansion port CR10 v2B 01 RS232 set Version with RS485 expansion port CR10 v2B 01 RS458 set Version with MBUS expansion port CR10 v2B 01 MBUS set Version with CNT expansion port CR10 v2B 01 CNT set Table 4 Ordering codes of basic version 5 4 2 Full version Version without expansion port CR10 v2F 01 set U Version with Ethernet exp port PORTI CR10 v2F 01 ETH set Lo Version with RS232 exp port PORT1 a PORT2 CR10 v2F 01 RS232 set Version with RS485 exp port PORT1 a PORT2 CR10 v2F 01 RS458 set e Version with MBUS exp port PORTI a PORT CR10 v2F 01 MBUS set Version with CNT exp port PORTI CR10 v2F 01 CNT set ps Version with SWITCH exp port PORT1 PORT2 CR10 v2F 01 SWITCH set Version with WIFI exp port PORT2 CR10 v2F 01 WIFI set Version with WMBUS exp port PORT2 CR10 v2F 01 WMBUS set Lom Version with SDH exp port PORT2 CR10 v2F 01 SDH set Table 5 Ordering codes of full version Second expansion port is written after first expansion port in the ordering code Ex
11. 60 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 EN Cone wm A B amp B ELECTRONICS Company 5 ROUTER DESIGN 9 Router design 5 1 Router versions CR10 v2 router is supplied in the following versions A E E EA O A pra CR10 v2B Plastic A CR10v2B SL Metal 4 4 4 Y Y CR10 v2F Plastic 4 Y 4 4 4 Y 4 CR10 v2F SL Metal Y 4 4 Y Y A 4 Table 1 Router versions O piv CR O v2 zem E ELP ELP l Le In I 0 m PORT1 DIV CERTO y2 ANT WAN DAT PWR us gt a ooo C A O oo O use IN OUT O use IN OUT O fe 1 En O e ele In 1 0 RUE PORT1 Figure 2 Front panel CR10 v2B me CRIO YZ ANT O npiv CR O v2 ant O OUT IN USR SIM2 SIM WAN DAT PWR OUT IN USR WAN DAT PWR O OP Q O C JLI EP LI a PUR o o es USB PORT2 PORTI ETH E PORT2 PORTI Figure 3 Front panel CR10 v2F Figure 5 Front panel CR10 v2F SL 5 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone um A B amp B ELECTRONICS Company 5 ROUTER DESIGN 5 2 Delivery identification Trade name Type name Other NN CE NT Figure 6 Label CR10 v2B CR10 v2B 01 SL CR 10 v2 03 vesovissw AO NN at Conel um Conel s r o ESN SGA SDAE CR10 v2B CR 10 v2 Basic version CR10 v2B SL CR 10 v2 Basic version in th
12. 60 20 www lucom de 19 06 15 EN Cone wm A BSB ELECTRONICS Company o 5 ROUTER DISSIICIN 5 9 1 Status indication About router status inform eight led indicators on the front panel and on every port are two LED indicators which inform about port status Caption Color State Description NN PWR Green Blinking Router is ready On Starting of the router Fast blinking Updating firmware DAT Red Blinking Communication in progress on radio channel WAN Yellow 1x flash per second Signal strength is from 50 dBm to 69 dBm 2x flash per second Signal strength is from 70 dBm to 89 dBm or differ ence between neighbours cells is exactly 3 dBm 3x flash per second Signal strength is from 90 dBm to 113 dBm or differ ence between neighbours cells is smaller than 3 dBm USR Yellow Function selected by user OUT Green On Binary output active IN Green On Binary input active ETH Green On Selected 100 Mbit s Off Selected 10 Mbit s ETH Yellow On The network cable is connected Blinking Data transmission Off The network cable is not connected U PORT Green Depends on the expansion port see user s guide of used port JO PORT Yellow Depends on the expansion port see user s guide of used port SIM1 Yellow On SIM card 1 is active O SIM2 Yellow On SIM card 2 is active Q Table 7 Router status indication a O State indication of WAN LED is updated every 10 seconds 9 em QU Lo e Q 14 LUCOM GmbH Ansbacher Str 2a
13. 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de 19 06 15 EN Cone wm A BSB ELECTRONICS Company 5 ROUTER DISSIICIN 5 9 2 Power connector PWR Panel socket 2 pin OZA KEON Description VCC Positive pole of DC supply voltage 10 to 30 V DC 2 GND Negative pole of DC supply voltage Table 8 Connection of power connector O feji 0 Figure 21 Power connector Power supply for router is required between 10 V to 30 V DC supply Protection against reversed polarity without signaling is built into the router The power consumption during receiving is 2 3 W The peak power consumption during data sending is 5 5 W However values of consumption can be increased if some expansion port is eqquipped For correct operation it is necessary that the power source is able to supply a peak current of 1 A Connector on the power cable connects into the power connector on the router head and tightens locking screws see figure below Figure 22 Connection of power supply connector Circuit example Pin 1 VCC Pin 2 GND Figure 23 Connection of power supply The positive pole VCC is marked by a red socket on the power 15 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone um A BSB ELECTRONICS Company as 5 ROUTER DESIGN 5 9 3 Antenna conne
14. Conel Conel Conel Conel Start guide Configuration manual User s manual Expansion port RS232 User s manual Expansion port RS485 RS422 User s manual Expansion port MBUS User s manual Expansion port CNT User s manual Expansion port ETH User s manual Expansion port SWITCH User s manual Expansion port WIFI User s manual Expansion port WMBUS User s manual Expansion port SD Application guide Expansion port mounting Application guide Programmer guide 28 info lucom de O E e UO E z z 19 06 15 Wu Cone wm Bam crcomones Coney 9 POSSIBLE PROBLEMS 9 Possible problems e Some network cards are able to be set in situation when it is not possible to connect the router It is possible to solve this problem in the following steps e hand by selection communication rates 10 MB s in property network cards e connect router over switch e Start computer only after finalizing the start of the router 29 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de QU Ko e O e e Gan E www lucom de 19 06 15 EN Cone wm A B amp B ELECTRONICS Company 10 FAQ n cant get from internet on equipment which is connected to router and have NAT en abled e The device s gateway has to be configured as the router 2 Router resets itself connection on Etherne
15. TT Un C Onc EM The connecting amp monitoring company A BSB ELECTRONICS Company Ge EEE Sam q 1009 i N b o COMA router CR10 v2 USER S MANUAL OUT IN USR SIM2 SIMI WAN DAT PWR w u CRIO v2 wr O em CRIO v2 OUT IN USR SIM2 SIM1 WAN DAT PWR 19 06 15 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de o Ko e o O Gan C www lucom de 19 06 15 Wu Cone wm BOBELO OG covey USED SYMBOLS Used symbols Danger important notice which may have an influence on the user s safety or the function of the device Attention notice on possible problems which can arise in specific cases Information notice information which contains useful advice or special interest asb GPL license Source codes under GPL license are available free of charge by sending an emall to info conel cz Conel s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Manual issued in CZ November 27 2014 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone um A B amp B ELECTRONICS Company CONTENTS Contents 1 Safety instruction 1 2 Product disposal instructions 2 3 Router description 3 4 Contents of package 4 5 Router design 5 dd ROMGFVEISIONS a 2 3 xx rua
16. ample e Full version with Ethernet and RS232 port CR10 v2F 01 ETH RS232 set e Full version with Ethernet and RS232 port in metal cover CR10 v2F 01 ETH RS232 SL set O E e UO E z z LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de 19 06 15 Wu Cone wm A BSB ELECTRONICS Company 5 ROUTER DESIGN 50 E Spoce for data 1 connectors and doto cobles 83 7 DIN roi 35mm Position DIN roi 35mm Positon B Figure 10 Basic dimensions of plastic box 5 6 Basic dimensions of metal box 50 q q E Space for dato connectors and doto cobles DIN roi 35 mm Figure 11 Basic dimensions of metal box LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de 80 3 QU Lo e O e e Gan E www lucom de 19 06 15 Wu Cone um A BSB ELECTRONICS Company 5 ROUTER DESIGN LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de 5 Mechanical dimensions and mounting recommendations Mounting recommendations e possibility to be put on a work surface e DIN rail with clips CKD2 ELPAC clip SL for metal version are included For the most of applications with a built in router in a switch board it is possible to reco
17. ation see Configuration manual because after reset router set configuration to the initial state 23 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 6 FIRST USE 6 First use 6 1 Connecting the router before first use Before you give up the router it is necessary to connect all components needed for the operation of your applications and the SIM card must be inserted see figure below Y The router can not operate without connected antenna SIM card and power supply If the antenna is not connected router can be demaged Lightning arrester optional PWR circuitry see chapter 5 9 2 ETH circuitry see chapter 5 9 5 PORT1 circuitry see manual of corresp exp port PORT2 circuitry see manual of corresp exp port USB circuitry see chapter 5 9 8 lO circuitry see Lightning chapter 5 9 8 arrester optional Figure 39 Router connection 24 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 EN Cone wm A BSB ELECTRONICS Company A 6 z RST U S E 6 2 Start The router is set up connecting the power supply to the router In the default setting the router starts to login automatically to the preset APN Device on the Ethernet port DHCP server
18. c is essential Cellular wireless routers may automatically upgrade configuration and firmware from server This allows mass reconfiguration of many routers in one time For easy use additional software may be used communication VPN server Digicluster and software for router monitoring R SeeNet Examples of possible applications mobile office fleet management security system telematic telemetric remote monitoring vending and dispatcher machines LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone um A BSB ELECTRONICS Company 4 CONTENTS OF PACKAGE 4 Contents of package Basic delivered set of router includes router power supply crossover UTP cable two external antennas clip for the DIN rail installation CD containing instructions paper start guide piv A ae CRIO v2 UT IN USR SIM2 SIMI WAN DAT PWR te o ammo 2 1 Figure 1 Contents of package Note The router box and DIN mount are supplied in a metal case in the SL version o The router can also be supplied as expansion accessories e One Basic version or two Full version expansion ports RS232 RS485 422 MBUS ETHERNET CNT SWITCH WIFI WMBUS or SDH Separation columns for mounting expansion boards are included LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 4
19. ced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimize the impact on the environment This product contains high quality materials and components which can be recycled At the end of it s life this product MUST NOT be mixed with other commercial waste for disposal Check the terms and condi tions of your supplier for disposal information LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 EN Cone wm A B amp B ELECTRONICS Company 3 ROUTER DESCRIPTION 3 Router description CDMA wireless router CR10 v2 is used to wirelessly connect various equipments and de vices via Ethernet interface 10 100 to the Internet or intranet Thanks to high data transfer speed of up to 14 7 Mbit s download and upload speed up to 5 4 Mbit s it is an ideal wire less solution for traffic and security camera systems individual computers LAN networks automatic teller machines ATM and other self service terminals etc As a standard this exceptionally CR10 v2 wireless router is equipped with one Ethernet 10 100 one USB Host port one binary Input output I O port and one SIM card To save and backup communication data a version with two SIM cards is available The wide range of interface options of the CDMA router further expands Port1 and Port2 expansion ports which are
20. ctor ANT DIV alternatively WIFI or WMBUS Main and diversity antennas are connected to the router using the SMA connector on the front panel If WIFI or WMBUS expansion port is eqquiped on customer s request on the front panel is also available the third SMA antenna connector through which the additional antenna can be connected it is reverse connector R SMA in case of the WIFI expansion port de The router can not operate without the main antenna connected labeled as ANT ANT connector is used to connect the main antenna router To connect the diversity an tenna is used the second antenna connector marked as DIV If WIFI or WMBUS expansion port is eqquiped on customer s request there is also available WIFI or WMBUS antenna con nector for connecting corresponding antenna Example of antenna Figure 24 External antenna For connection the antenna is used SMA connector The antenna is connected by screwing this antenna to the SMA connector on the front panel of the router see figure below info lucom de Figure 25 Connecting of the antenna Diversity antenna improves radio features of the router at low signal strength O E e UO E z z 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de 19 06 15 EN Cone wm A B amp B ELECTRONICS Company 5 ROUTER DESIGN 5 9 4 SIM card reader The SIM card rea To initiate the router der fo
21. e if the router is switched to offline mode by SMS message the router will be in this mode up to next restart This behaviour is the same for next all control SMS messages info lucom de O E e UO E z z 31 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de 19 06 15 Wu Cone wm ine 11 CUSTOMERS SUPPORT 11 Customers support You can find current information about this product on our website Www conel com Upkeep advices e The SIM card must be handled carefully as with a credit card Don t bend dont scratch on this and do not expose to static electricity e During cleaning of the router do not use aggressive chemicals solvents and abrasive cleaners Conel Company hereby declares that the router narrated in this user s guide fits all basic de mands of directive 1999 5 EC R amp TTE Router fits values of coefficient SAR defined by association ICNIRP and values of About pro tection of health before non ionized radiation C Declaration of conformity was issued and it is possible to find it on the Conel web site http www conel com download or at producer Please use the following login information Username ConelFreeDownload Password coneldownload 32 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z
22. e metal box CR10 v2F CR 10 v2 Full version CR10 v2F SL CR 10 v2 Full version in the metal box Table 2 Delivery identification CR10 v2B 01 CR10 v2F 01 CR 10 v2 ver 03 CR 10 v2 ver 03 ces MAINA TI see ONLI ats P um Tue LQ Tue iQ HCE INI Figure 8 Label CR10 v2F CR10 v2F 01 SL CR 10 v2 ver 03 10 30V 5 5W at Conel wm Conel s r o ESN SOAGIDAE HCE INI Figure 7 Label CR10 v2B SL HCE INI Figure 9 Label CR10 v2F SL LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E E e UO E z z 19 06 15 EN Cone wm A BSB ELECTRONICS Company 5 ROUTER DISSIICIN 5 3 Version of firmware module Each operator can have another CDMA network so it is necessary to generate a special firmware for each operator Version of the firmware is indicated by two digit code in the name of the product Poland Orange 01 Poland Plus 02 Czech Republic 02 03 Germany Inet 04 Sweden Net 1 05 Norway Net 1 06 Russia Skylink 07 Ukraine MTS 09 Romania Romtelecom 10 Togo 11 Austria Kapsch 12 Hungary Mavir 14 Netherlands Alliander 15 Austria Kapsch EAG 16 Table 3 Version of firmware module Example of trade name CR10 v2B 01 Example of type name CR 10 v2B ver 01 info lucom de O E e UO E z z LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127
23. gnize two kinds of environments e no public and industry environment of low voltage with high interference e public environment of low voltage without high interference For both of these environments it is possible to mount router to a switch board the following there is no need to have examination immunity or issues in connection with EMC according to EN 60439 1 ed 2 00 A1 04 For compliance of EN 60439 1 ed 2 00 A1 04 specification it is necessary to observe next assembly of the router to the switch board e for whip antennas we recommend to observe a distance of 6 cm from cables and metal surfaces on every side according to the next picture due to the elimination of interfer ence while using an external antenna except for the switch board it is necessary to fit a lightening conductor e before mounting a router on sheet steel we recommend using an external antenna Figure 12 Space around antennas Figure 13 Space around antennas for SL 10 info lucom de O E e UO E z z 19 06 15 Wu Cone wm Vv e For every cables we recommend to bind the bunch according to the following picture we recommend for this use Length of the bunch combination of power supply and data cables can be max imum 1 5 m If the length of data cables exceeds 1 5 m or in the event of the cable leads towards the switch board We recommend installing over voltage protectors surge suppressors Wi
24. guration Maximum load binary output is 30 V 100 mA The constant current supplied by the binary input is 3 MA Connector I O cable connect into the I O connector on the router head and tighten locking screws see figure below Figure 36 Connection of I O cable Circuit example of a binary input or output equipment with router PIN 1 BIN PIN 3 OUT Pojistka E 3 Figure 37 Connection of input and output to the router 22 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone um A BSB ELECTRONICS Company 5 ROUTER Dare Cin 5 9 10 Reset O It is important to distinguish between reset and reboot the router Action Router behavior Invoking events Reboot Turn off and then turn on router Disconnect and connect the power Press the Reboot button in the web configuration Reset Restore default configuration and reboot Press RST button the router Table 12 Description of reset and restart router After green LED starts to blink it is possible to restore initial settings of the router by press ing button RST on front panel After press button RST it is restoration of default configuration and reboot green LED will be on For pressing the RST button could be used a narrow screwdriver Figure 38 Router reset ab We recommend to backup your router configur
25. ne pau FEES 6 Label CR10V2F 1 a 6 Label CRIOV2F SL escocesas artesa ass 6 Basic dimensions of plasticbox 9 Basic dimensions of metal box 9 Space around antennas a so 10 Space around antennas for SL 10 Cable routing sos ees 11 Cable routing for SLversion 11 Space in front of connectors a a 11 Space infrontofconnectiors SL 11 Default position of DIN holder a 12 Removing from the DIN rail oaoa aaa a 12 Front panel CR10 v2F SL ahaaa a 13 Power connector soso oso sos ns 15 Connection of power supply connector 15 Connection OfpowerSUDDIY 15 External antenna oso oso oseo 16 Connecting of the antenna oso 16 Ejected SIM holder ose os soso 17 Ethernet connector 22er 18 Connection of ethernet cable 18 Example of router connection lll ln 18 PORTI cable connection sos os ose so 19 PORT2 cable connection ee rn 20 USB connector 1 soo ose os oseo 20 Connection PLC tothe router 21 Connection flash memory totherouter 21 OCODE oe Gb ee ees oe ews oe e apu o e eG l gy uke 21 Connection
26. of I O cable 22 Connection of input and outputtotherouter 22 Router reset mo LN he ess we x om muy kikis a 23 Router connection llle lees less 24 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone wm A BSB ELECTRONICS Company LIST OF TABLES List of Tables ONO a BON LA lll Oo DOI SOI ALO SOUIEFVEISIONS e siau kekxs cis ees eee nuk SN Zu egoo kdm sa Ke 5 Delivery identification soso ose oso 6 Version of firmware module o oso 7 Ordering codes ofbasicversion ee 8 Ordering codes of fullversion soso 8 Front panel description a 13 Router status indication o a 14 Connection of power connector oseo 15 Connection of Ethernetconnector 17 Connection of USBconnector 20 Connection of I O port oseo 21 Description of reset and restart router 23 Technical parameters of router 26 Technical parameters of module 26 Technical parameters of processor 27 Technical parameters llOport
27. r 3 V and 1 8 V SIM cards is located on the front panel of the router into operation it is necessary to insert an activated SIM card with un blocked PIN in the reader The SIM cards might be of different adjusted APN Access Point Name Changing the SIM card Vv Before handling of the SIM card turn off the router and disconnect it from power supply Press the small yellow button to eject the reader holder Insert the SIM card into the reader holder and slide it in the reader see figure below Figure 26 Ejected SIM holder 5 9 5 Ethernet port Panel socket RJ45 Pin Signal mark Description _ Data flow direction TXD TXD RXD CON OOF W ID LUCOM GmbH Ansbacher Str Transmit Data positive pole Input Output Transmit Data negative pole Input Output Receive Data positive pole Input Output Receive Data negative pole Input Output Table 9 Connection of Ethernet connector 1 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone wm A BSB ELIO 5 ROUTER DIS IN Figure 27 Ethernet connector O ATTENTION Port ETH is not POE Power Over Ethernet compatible Ethernet cable plug into the RJ45 connector labeled as ETH see figure below Figure 28 Connection of ethernet cable Example of the ETH router connection Switch Figure 29 Example of
28. root with initial password root A detailed description of the router settings via the Telnet interface can be found in the con figuration manual 25 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 EN Cone wm A BSB ELECTRONICS Company 7 TECHNICAL PARAMETERS 7 Technical parameters 7 1 Technical parameters of router CR10 v2 Complies with standards Temperature range Protection Supply voltage Consumption Dimensions Weight Antenna connector User interface Function Storage Freely In switch board Reception CDMA Plastic box Metal box ETH USB PORT1 PORT2 EN 301 526 v1 1 1 EN 62311 2008 ETSI EN 301 489 25 v2 3 2 EN 60950 1 06 ed 2 A11 09 A1 10 A12 11 Opr 1 12 30 C to 60 C 40 C to 85 C IP20 IP56 10 to 30 V DC 2 3 W to 4 W 51x 8 7x116 mm DIN 35 mm 42x87 x113 mm DIN 35 mm CR10 v2 150g CR10 v2 SL 280g SMA 50 Ohm Ethernet 10 100 Mbit s USB 2 0 On customer s request On customer s request Table 13 Technical parameters of router 7 22 Technical parameters of module CDMA modul Rev A Bit rate 3 1 Mbps DL 1 8 Mbps UL Rev B Bit rate 14 7 Mbps DL 5 4 Mbps UL Backward compatible with Rev O 23 0 dBm 30 0 dBm 450MHz Sub band A B L 800MHz amp 1900MHz dual or single CDMA parameters
29. s of your server with static IP address and by the help of the router address verify and address in ping e Firewall is possible to verify for example by remote access on web interface O E e UO E z z 30 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de 19 06 15 Wu Cone um A B amp B ELECTRONICS Company e The operator doesn t give out address DNS servers and without DNS server s it is impossible to connect to server dyndns org In log system will be this message DynDNS daemon started Error resolving hostname no such file or directory Connect to DynDNS server failed n PSec tunnel is establishing but communication doesn t function e Probably it is badly set up route conditionals of connected equipment or it is bad set up GW n FTP doesn t function e Router doesn t support the active FTP mode supports the passive mode only 0 RS232 doesn t function e lt is necessary to verify present the expansion port RS232 e Verify present the expansion port RS232 in router configuration in menu external port or verify connection locally by the help Telnet Hyper terminal 0 L2TP or IPSec isn t establishing e Verify the reason in the log system 2 switched the router to offline mode by the SMS message but the router is in online mode after restart e Control SMS messages don t change the router configuration For exampl
30. t fails e t is necessary to use an antenna which will be situated far from power supply n dont get on web server at NAT e The remote http access of the router has to be disabled default server address has to be your web server and the gateway of the web server has to be the IP of router n PPP connection fails e Check signal power If signal power is weak you will have to use a better antenna If the environmental cells have a similar signal it will be necessary to use a directive antenna Signal levels have to be in the range 50 dBm and 90 dBm e t is necessary to set ping which will check the connection and in the case of fail ping restart connection n PPP connection won t be established e Recheck GPRS settings APN name password and IP address e Try to enter PIN verification if the SIM card hasn t set PIN code e In private APN it is appropriate to switch the DNS server send off e Switch log system on and observe where the error turns up info lucom de n Connection fails on Ethernet or connection isn t establishing e On ethernet interface of the router it is possible to switch auto negotiation off and set a rate and duplex by hand n DynDNS not function e In private APN not functional e If the same IP address is recorded in your canonic name as dynamically assign address it means that the operator is using NAT or firewall e NAT is possible to verify by the help of the ping on addres
31. th data cables they mustn carry cables with reticular tension 230 V 50 Hz All signals to sensors must be twisted pairs Figure 14 Cable routing Figure 15 Cable routing for SL version q e Sufficient space must be left before individual connectors for handling of cables Figure 16 Space in front of connectors Figure 17 Space in front of connectors SL O e For correct function of the router we recommend to use in the switch board earth bonding distribution frame for grounding of power supply of router data cables and antenna 11 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone wm A BSB ELECTRONICS Company a or ROUTER Dim IN 5 8 Removing from the DIN rail Default position of CPD2 holder or CKD2 holder for SL version which is used for mount ing the router on a DIN rail is shown in the following figure 3 3 Figure 18 Default position of DIN holder For removing from the DIN rail it is necessary to lightly push upward the router so that the top part of the CPD2 holder or CKD2 for SL version hitched to the DIN rail get out of this rail and then fold out the top part of the router away from the DIN rail Figure 19 Removing from the DIN rail 12 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59
32. tions of flammable and explosive materials We remind the users of the duty to observe the restrictions concerning the utilization of radio devices at petrol stations in chemical plants or in the course of blasting works in which explosives are used Switch off the router when travelling by plane Utilization of the router in a plane may endanger the operation of the plane or interfere with the mobile telephone network and may be unlawful Failure to observe these instructions may result in the suspension or cancellation of telephone services for the respective client or it may result in legal sanctions it may also result in both eventualities When using the router in the close proximity of personal medical devices such as cardiac pacemakers or hearing aids you must proceed with heightened caution If it is in the proximity of TV sets radio receivers and personal computers the telephone may cause interference It is recommended that you should create an appropriate copy or backup of all the im portant settings that are stored in the memory of the device LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de info lucom de O E e UO E z z 19 06 15 Wu Cone wm A BSB ELECTRONICS Company Dn PRODUCT DISPOSAL INSTRUCTIONS 2 Product disposal instructions The WEEE Waste Electrical and Electronic Equipment 2002 96 EC directive has been introdu
33. will assign addresses The behavior of the router can be modified by means of the web or Telnet interface which is described in the configuration manual The power consumption during receiving is 2 3 W The peak power consumption during data sending is 5 5 W However values of consumption can be increased if some expansion port is eqquipped For correct operation it is necessary that the power source is able to supply a peak current of 1 A 6 3 Configuration Attention If the SIM card is not inserted in the router then it is impossible to operate The inserted SIM card must have activated CDMA 6 3 1 Configuration over web browser Monitoring of the status configuration and administration of the router can be performed by means of the web interface which is available after insertion of IP address of the router into the web browser The default IP address of the router is 192 168 1 1 Configuration may be performed only by the user root with initial password root A detailed description of the router settings via the Web interface can be found in the con figuration manual 6 3 2 Configuration over Telnet Monitoring of status configuration and administration of the router can be performed by means of the Telnet interface After IP address entry to the Telnet interface it is possi ble to configure the router by the help of commands The default IP address of the router is 192 168 1 1 Configuration may be performed only by the user