Home
User' Guide - direktvomhersteller.de
Contents
1. to the control panel water bottom light loudspeaker electrical engineering and the detector protection respectively 3 Water supply device 3 1 This device s hydraulic pressure is 0 2 0 4Mpa 3 2 The water supply characteristics on the wall The cold or hot water supplies inside the bathroom also establish in the shelter of the massage tub use the hose to connect with the cold or hot joint of the tub the pipe towards is decide by the customer the machine do not go with the hose 4 Installation introduction 4 1 Before install must consider the place of install massage bathtub whether can support this device s pressure 4 2 Place the massage bathtub on the install position adjust level to make the drain system smooth 4 3 Adjust the leg s screw to make sure all of the screw touch ground completely 4 4 Install the drain hose and make some measure to against on the connecter 4 5 Fix cold and hot water pipe well then install the showerhead And then put drain into downcomer finally connect with power and make sure whether device connected with ground can work 5 Using Method 5 1 Turn on faucet adjust water s temperature add water to the massage bathtub when the highest water level exceed the highest nozzle about 20 30mm and reach the detector press the switch button to let the electric machine 5 2 Revolve the adjust switch and choose the proper surf pressure 5 3 After finishing if should turn off pump at first then o
2. Massage bathtub Heating function This function is limited by PUMP the heater can be started normally only after PUMP starting When turn off the surfing function the heater will be turned off at the same time Press to turn on or off the heater Q Bubble bath Press to turn on or off the air pump The air pump will be turned off automatically every 60minutes Lamp Press AD to turn on or off the lamp Tap Press A or O to raise or lower the tap V Items For Attention 1 2 The system must be erected by qualified technical person and the leakage switch shall be mounted in place of easy control It must be connected firmly during erection In the case of loss due to improper earthling the manufacturer will not assume any responsibility The motor must be erected flatly and stably and the shell shall be firmly earthed The whole set is usually under standby state If it is not used for long time please pull off the master power switch During erection it is required to consider load capacity of power supply circuit otherwise it may influence the normal working ofthe system or cause accident During erection all the electric appliances and electric parts shall be provided with moisture resistant measures gt pe Page 7 of 7 User Guide IMPORTANT Read this manual before proceeding with installation of the bathtub and keep it with the other accompanying document
3. Welo open rt eat tch pees acturer will not be held liable for damages or a A aA by im doesn t work arora P Rok nnee alr switc Connect again or change i r g J y proper installation The air switch failure Change F Power s parameter is not same aS Connect with supplier 2 Follow the instructions contained in this manual when using the product nameplate 3 Before using the bathbub check the local voltage that if reach to the Bignoseol machine Fixed screw did n fix or fall off Fix tightly again rated voltage pre installation card Support s leg screw did not touch A graund g Adjust Aging Change water pipe leak out The joint did not fix well Fix again Water pipe or accessory leak Change C O N T E N T S Remark except this fault please according to situation to resolve or find experienced people to repair 8 special remind 8 1 please find qualified people to install bathtub according to introduction 8 2 when you are using it first of all you have to inject the cold water and then inject the hot water Don t inject the hot water first 8 3 bathtub s machine must connect on ground support must use 1 5mm yellow green ll Brief Introd uction double wire connect with ground and check whether effective 8 4 please do not turn on machine without water before draining should turn off machine 8 5 children should be looked after in bathtub 8 6 bathtub s temperature cann t higher than people average temperature
4. and the best H C l RC U IT DIAG RAM is 32 37centigrade 8 7 after shower please cut off power 8 8 if have these situation please do not enter into massage bathtub IV CONTROL PAN EL DESCRIPTION 8 8 1 younger than 4 years old s child 8 8 2 blood circulation unstabled people 8 8 8 8 8 8 Safety Precautions co corona V Items For Attention 5 heart disease 8 8 6 already have sauna 8 8 7 after meal in half a hour Remark our company has the right to modify the above mention without further notice gt pe Page 3 of 7 gt pe Page 4 of 7
5. ater is as big as both sides 20sec The left side is bigger than the right side 20secs The right side is bigger than the left side ele As big as both sides Such loop is operated until PUMP be turned off gt pe Page 6 of 7 Massage bathtub Safety Precautions Warning 1 In order to prevent fire or electric shock accident do not expose the controller to the rain or humid environment There are dangerous high tension fittings inside the controller therefore do not open the cover Entrust the repairing work only to the qualified professional repairing personnel when repairing is required 2 Without the clear approval from the controller manufacturer or its authorized units any change or alternation to this controller might bring various inconveniences to the users when in use Helpful suggestion 1 In order to prolong the service life of this controller the time interval for continuously turning on and off the machine must be over 30 seconds 2 Please switch off the power after use 3 The power supply used must be consistent with the voltage specified value indicated on this controller otherwise it will not work or even burn out the controller 4 When installing this controller carefully check if the load parameters are consistent with the parameters required by this controller otherwise it will not work or even burn out the controller 5 If itis halted accidentally please close and restart ll Br
6. ief Introduction 1 General Description of Functions Functions Monel Ws 01 Inducing technology af Lamp Pump J J Blower af x J oO R oO hM a Heater 6 Leveldetection SPECIFICATIONS Power supply AC220V 10 50 60Hz 7 Jacking motor AC12V 40W Pump load AC220V 750W 8 Magnetic valve DC12V 30W Pump load AC220V 750W 9 Dielectric strength 1500V 5MA 1min Air pump load AC220V 350W 10 Leak current lt 0 25mA Heater power AC220V 2000W 11 Waterproof grade IPX4 Lamp load AC12V 20W onkwonr N mp Page 5 of 7 Massage bathtub 1 Electricity parameter Rated voltage Rated power Rated electric current Reference circuit voltage 220VAC 950W lt 4A 12V 2 Electric installation 2 1 power supply s establishment should be compled with nation security standard voltage and frequency also shoule be accord withproduct s nameplate Especially install creep age protect switch and also check whether can connect with ground 2 2 The wire collected to the massage bathtub should be fitting permanent and the wire should be a three core wire the sectional acreage of each core cannotless than 12A when wire pass the wall it should be use bushing for protection until the AC outlet 2 3 Ground wire of bathtub should be test whether works with house appliance ground wire 2 4 The wire end of electricity control box should connect
7. pen drain button when water is all out please make aclean of bathtub to keep in good 6 Clean and keep in good condition 6 1 usually use soft cloths and general liquid cleanser can wash away dirt but forbid to use the cleanser with acetone or the ammon ia composition when disinfect forbid to use the disinfector contained the formaldehyde 6 2 the dirty spot of surface can use the toothpaste to wipe with the soft cloth 6 3 to the low grade chafe of the surface or burned by cigarette can soak in water to whet with 2000 levigation sand paper then polishing 6 4 If the electroplate piece contain stain use the soft cloth to wipe lightly avoid to wiping with coarse cloth 6 5 often clean up the backwater net cover prevent it from stop gt Page 2 of 7 Massage bathtub Massage bathtub 5 a 6 6 Check whether have break on pipe and waterway aperiodically Bat htu b U ser s G ul d e 6 7 Please check whether there is fall off or breakage on wire switch connector plugs so that repair in time 6 8 In order to keep to use in a long term please reme mber don t use more than 3 hours continuely WAR N N G S 7 Fault eliminate Fault Cause Way Voltage unstable Check circuitry 1 Please follow the instruction contained in the attached installation Power connector didn t connect Insert again or change manual to ensure that the product is installed properly the manuf Machine or equipment
8. s This manual is valid for the installation of tubs both with and without whirlpool MODEL M 1108A 1108B SIZE 2000X900X620mm Massage bathtub Install the diagram a 2000 7 1200 nect the cold blue hot red pipe line connect the power supph 490 620 Lifting boxes Plane chart j 2000 7 b 1200 7 Waterfall intake 450 Tt l oO ie Cold and Hot water switch ia Drainage brg CoO oO Sprinkler a wal ia a Exchange switch p a el a Pillow Blower light Touch Control Pane J Invisible Control Panel Return net 4 Tap takes over sketch Cold water Waterfall drain Sprinkler drain Clear drain Hot water gt Pp Page 1of7 Massage bathtub lIHI CIRCUIT DIAGRAM AC220V AC12V 30W 000000 iS WATER PUMP WATER PUMP AIR PUMP 750W 750W 350W IV CONTROL PANEL DESCRIPTION 0900 PUMP PUMP AIR PUMP UPWARD HEATER LAMP DOWNWARD 5 OPERATING INSTRUCTION Surfing function The water level must meets the standard to launch this function Press O a PUMP ON PUMP ON gt PUMP OFF gt PUMP OFF Such loop is operated The pump will be turned off automatically every 60 minutes Waterfall After turn on PUMPQ the w
Download Pdf Manuals
Related Search
Related Contents
Samsung CE1000T-S คู่มือการใช้งาน Numark Industries AXIS 9 User's Manual スマートターミナル EST240Z 取扱説明書 注意 警告 Manuale tecnico (serie RRPLUS) Plug-N-Run G5-E1 Development Board User Manual Gigabit Ethernet PCIe 1000SX/LX Fiber Adapter User`s Manual Modular SCR Power Control Service Manual Copyright © All rights reserved.