Home

AutoRAE Lite User's Guide

image

Contents

1. Date Time 6 9 201 45 45 31 PM Setting SN T0110037Q3 Clock from PC e Yes C No Yes C No 31 AutoRAE Lite User s Guide 9 6 3 ToxiRAE 3 Screen Click on the ToxiRAE 3 icon or text in the left pane and the lower right pane now shows its editable functions that affect a ToxiRAE 3 in the AutoRAE Lite s dock These include e Show Sensor Reading Tells the ToxiRAE to show the sensor reading always or only when an alarm sounds Password Changes the password in the ToxiRAE 3 When you click Set the parameter changes are set in any ToxiRAE 3 that is in the AutoR AE Lues dock Important If you do make parameter changes on the screen but do not click Set the changes are not transferred to the ToxiRAE 3 Changes are only transmitted and registered by clicking Set AutoRAE Lite Utility Program TEM x File Operation Option View Help W amp 5 9 Instrument Name ToxiRAE 3 Serial Number G6122717R3 Firmware Version U2 18 Current Status Show Sensor Reading Normal Always Socket Index 1 Sensor H2S ppm Enabled Yes Information Firmware Ver om Status Status Normal Date Time 679 201 45 45 39 PM Setting SN 6012271783 Reading C On Alam Sensor Socket Status Events s Get Events Save Events Ready NM Z 32 AutoRAE Lite User s Guide 9 6 3 1 Getting Events Data
2. Language IS tox3_treatmentplant1_H2S mcfg File name 4 The information saved in the configuration file is now shown in the lower pane of the pop up window so that you can ensure that you have the correct configuration file and that its parameters are the ones you want to load into the AutoRAE Lite Utility and eventually into your monitors Load Monitor Configuration X Lookin AutoRAE Lite Utility Program CB El Mame sl Date modified Type di Language 6 9 2014 5 15PM File folder A Template Recyder22 H25 SecondQuarter mcfg Instrument Hame Serial Number Firmware Version Current Status Show Sensor Reading Socket Index Sensor Enabled Passuord Sensor Hame Calibration Date Cal Due Date Cal Interval Bump Date 6 9 20145 15PM File folder 6 9 2014 5 38PM MCFG File ToxiRAE 3 hB122717R3 02 10 Normal Always i H2S ppm 5 28 2815 18 38 88 AH 1171972014 180 days 6 9 2674 11 39 00 AH Important Always double check the configuration settings to ensure they are correct If they are not correct or if due dates have passed use another configuration file or create a new one 37 AutoRAE Lite User s Guide Click Set to load the configuration into the AutoRAE Lite Utility J4 Language 5 13 2014 11 21 File folder 1 Template 5 13 2014 11 21 File folder 5 27 2014 2 21PM MCFG File Recyder22 H2S FirstQuarter mcfg R
3. Once the information is acquired the main screen is populated with information inix File Operation Option View Help ISIN amp 5 9 9 AutoRAE Lite T0110037Q3 Instrument Name AutoRAE Lite Serial Number 1611663703 Firmware Version U1 38 Working Status Normal Power Status External Power Cal If Bump Fails Yes Clock from PC Yes Location Gas Lot No 6666666666 Information Gas Lot Setting Firmware Ver Iv 20 Gas Lot No Status Status Normal Power External Power Date Time 6 9 2014 6 15 32 PM Setting SN T0110037Q3 Location Clock from PC Cal If Bump fails In the left pane is an icon for the AutoRAE Lite and its serial number The upper right pane provides a synopsis of information acquired from the AutoRAE Lite including Instrument Name Serial Number and Firmware Version It also provides functional information including Working Status and Power Status battery or external power Finally it shows preferences that can be set in Administrator Mode including Calibrate If Bump Fails Clock From PC synchronizes time in the AutoRAE Lite to the computer s time and Gas Lot Number in case you want to keep a record of which gas lot the calibration gas comes from The bottom portion is grayed out indicating that the parameters are being read but cannot be altered in User Mode 22 AutoRAE Lite User s Guide 9 4 2 With A ToxiRAE
4. 4 gt k 3 items 4 Create a new folder on your desktop or elsewhere on your computer 5 Drag the file s from the SD card into the folder on your computer ENS O x File Edit View Tools Help Organize e Sharewith e Burn New folder Jr Favorites _ Name WE Desktop BUMPTEST 8 Downloads CAL DATA 5 Dropbox d EVENT 1 Recent Places 159 Libraries _ Documents Lk 3 items nl 2014 Data 6 Open the folder to make sure the files have transferred correctly 13 AutoRAE Lite User s Guide Inside each folder is a file with an 8 character name that starts with the letter of the type of file bump test calibration data or events The first two digits indicate the year the second two digits indicate the month and the ending of V1 is a reserved tag For example an events file appears like this E0802_V1 This indicates that it is an event log from the year 2008 and the month February Note Once the files are transferred from the SD card to your computer you may change the name of the file to suit your needs For instance you may want to append the date and or time to the name for example E0802 V Februaryl12 08 15 to indicate that it was offloaded on February 12 at 8 15AM 8 2 After Transferring Data From The SD Card Once you have transferred the files from the SD card to your computer you can open them in a spreadsheet program such as Microsoft Excel or in a word pr
5. From A ToxiRAE 3 The lower right pane has a section devoted to events information which is stored in the ToxiRAE 3 This is read only data but can be imported To import the events information click Events As the information 1s collected you see this pop up window Get Event Information 33 m Wait for a moment The information is organized in an index of events with sensor type date time type of event and reading EEE Utility Program File Operation Option View Help EC EEE C S AutoRAE Lite T0 11003703 Instrument Name ToxiRAE 3 CN ToxiRAE 3 G0122717R3 Serial Number G6122717R3 us Firmware Version U2 18 Current Status Normal Shou Sensor Reading Always Socket Index 1 Sensor H2S ppm Enabled Yes Paccunr d 444 Information Firmware Ver Bei 0 Status Status Normal Date Time 5 23 2014 3 36 48 PM Setting sw Josee Show Sensor amp Always Reading C On Alarm Sensor Socket Status Date Time Event Reading 2014 05 23 14 31 34 BUMP EXPIRE 0 0 ppm 2014 05 23 13 17 57 BUMP EXPIRE 0 0 ppm 2014 05 20 09 38 34 BUMP EXPIRE 0 0 ppm 2014 05 20 08 15 14 BUMP EXPIRE 0 0 ppm 2014 05 1402 58 53 BUMP EXPIRE 0 0 ppm 2014 05 09 06 11 02 25 2 ppm 2014 05 09 05 51 13 BUMP EXPIRE 0 0 ppm WAN n1 NA NANN LT LI 29 nM eem Set Get Events Save Events Ready Wal 2 Password 111 1 2 3 4 5 6 7 o The number of events indexed depe
6. Guide 7 Click Browse ps RAE Programmer 7000 E X COM Port d Package Browse Package Information Processing Information 8 Locate the firmware update file on your computer it has a rfp suffix 9 Once you select the file click Open RAE Programmer 7000 opens 10 Click Go to start updating the firmware You receive the message Processing Information as the updating progresses RAE Programmer 7000 COM Port Package D Desktop AutoRAE Lite V1 00 RFP Package Information Product AutoRAE Lite Version 1 00 Package Code APODODE 100 BLOODOE 100 Create by RAE at 2007 11 08 00 26 18 Processing Information Duration 3 9 seconds sa 40 AutoRAE Lite User s Guide 11 When the firmware update is complete you receive the message Firmware loaded Please reset the unit Click Exit RAE Programmer 7000 COM Port b Package D DesktophAutoRAE Lite V1 0D RFP TERM Package Information Product AutoRAE Lite V ersion 1 00 Package Code APO000E100 BLOOOOE 100 Create by RAE at 2007 11 08 00 26 18 Processing Information Firmware loaded Please reset the unit Total used 46 2 seconds E xit 12 Unplug the USB cable and exit the AutoRAE Lite Utility Program 11 Formatting An SD Card If you purchase an SD card for use in an AutoRAE Lite it may need to be formatted before it is used RAE Systems SDHC c
7. Place the SD card into an adapter and connect it to a computer s USB port USB Place the SD card into an adapter and plug it into the USB port of a computer 3 Double click the Computer icon on the computer s desktop Computer 4 Thelist of Devices with Removable Storage should include your SD card with a title of Removable Disk or a name that indicates the SD card 42 AutoRAE Lite User s Guide P My Computer SEE File Edit View Favorites Tools Help a Qu gt ES Search 1 Folders Er Address d My Computer v EJ Go Name Type Total Size Free Space Comments System Tasks Hard Disk Drives View system information S Local Disk C Local Disk 15 Add or remove programs Q Change a setting Devices with Removable Storage amp j Eject this disk b DVD Drive D CD Drive 5 DVD RW Drive E CD Drive Other Places Removable Disk F Removable Disk Removable Disk F Properties General AutoPlay Tools Hardware Sharing eg Type Removable Disk File system FAT32 W Used space 32 768 bytes 320KB B Free space 1 013 514 24D bytes 966 MB Capacity 1 013 547 008 bytes 966 MB Drive F 6 Ifthe file system says FAT 32 then you can click OK and use or continue to use the disk If the disk is formatted for any other file system FAT or FAT 16 for example you should reformat it for FAT 32 Note If the disk is formatted for FAT 32 and you sim
8. blocked and that a filter is attached 1 Turn on the ToxiRAE 3 Press and hold its MODE button 2 After the ToxiRAE 3 has started and displays a reading press the Y button until its display shows Ir 3 Firmly press the ToxiRAE 3 face down in the dock on the AutoR AE Lite The two LEDs above the buttons should glow green If not make sure the ToxiRAE 3 is firmly seated 4 Press Bump to perform a bump test or press Cal to perform a calibration L E Note During a bump test or calibration the LED above the button turns off and the Bump status or Cal status LED blinks and is orange You will be alerted when the bump test or calibration 1s complete When the two indicator LEDs above the buttons glow green remove the ToxiRAE 3 from the dock Pass A green LED indicates the bump test or calibration was successful AutoRAE Lite User s Guide Fail A red LED indicates the bump test or calibration failed If a bump test or calibration fails check the calibration gas pressure and try again If it fails again it is possible the sensor is depleted and must be replaced 7 1 Status LED Explanation LED Solid Blinking Orange UM e range IT Battery low no external External N A N A power power or battery OK Bump Fal L ns N A Processing Service No SD card or N A N A SD card is locked or needs Request communication failure or to be formatted or SD SD card space is very low card space is
9. connectors Inspect the filter periodically and replace it as necessary AutoRAE Lite User s Guide 6 SD Memory Card The AutoRAE Lite electronically stores records of all bump tests and calibrations on an SD memory card RAE Systems part number 550 0301 000 IMPORTANT The SD card that comes with the AutoRAE Lite 1s pre formatted and ready for use If you purchase additional SD cards or SDHC cards from other sources they may need to be formatted before they can be used in the AutoRAE Lite Refer to Formatting An SD Card on page 41 for details Note The SD card inside AutoRAE Lite can only be used for AutoRAE Lite recording Do not save other files to the SD card Transferring records from the SD card to a PC on a regular basis 1s recommended This enhances data security and speeds the data transfer process IMPORTANT The AutoRAE Lite cannot perform a bump test or calibration without an SD card in its slot SD port cover closed SD port cover opened Inserting SD card into slot Press SD card into slot until L it clicks Inserting an SD card Press the SD card into the slot with the angled notch on the right Press until it locks into place making a click sound Removing an SD card Press the SD card and release it It will make a click and push part of the way out of the slot When an SD card is in the slot the Service Request LED is off When the ToxiRAE 3 is placed in the AutoRAE Lite the Bump and
10. must enter a password to place the program in Administrator Mode Operation Option View Help Setup Port Get Configurations F2 Operation Mode d v Goto User Mode MEE Go to Administrator Mode Load Monitor Gonfiquration Upgrade Firmware When the pop up window appears you must type in a password Go to Administrator Mode To go to the Administrator Mode type the correct password Password eee Change Password Note The default password is rae Click OK to register your password and enter Administrator Mode 29 AutoRAE Lite User s Guide Note You can change the password by clicking Change Password A dialog box prompts you to type in the current password and a new password twice to make sure that there is no mistake Change Password f Old Password New Password Confirm New Password After you are satisfied with the password click OK to save it Once your password is accepted the pop up dialog box disappears and the main screen is shown AutoRAE Lite Utility Program E inl x File Operation Option View Help ACEA Click Get Configurations As the connection is being made and the AutoRAE Lite configuration data is transferred a succession of three animated progress pop up windows is shown Get Tester Information 0 Get Monitor Information 50 _ Get Sensor Information 36 Wait for a moment A Wait for a
11. used in the AutoRAE Lite Remove it and place it in the AutoRAE Lite 45 AutoRAE Lite User s Guide 12 Maintenance Occasional cleaning of the AutoRAE Lite s exterior is recommended Use a damp cloth water only no solvents or cleaners to wipe the exterior case and the dock area Inspect the ports in the dock and the space between the Bump and Cal buttons and the case All of these locations are indicated below If dirt has settled into any of these places use a can of compressed air to blow it out Important Never use sharp tools or solvents to dislodge small obstructions If debris is lodged in any portion of the AutoRAE Lite and cannot be removed by compressed air or soft cloth refer it to qualified service personnel Check all of these locations for dirt debris and obstructions Inspect the AC adapter s wires the SD card slot the USB port the LEDs and the area around the Bump and Calibration buttons for dirt or debris Also check the two rectangular switch locations and the infrared communication port in the middle of the dock for dirt or debris Do not leave dead batteries in the AutoRAE Lite Over time they may leak or corrode causing damage to the components in the battery compartment Always use high quality alkaline batteries 46 AutoRAE Lite User s Guide 13 Troubleshooting Cannot perform Bump or Calibration Bump and Cal LEDs are dark and Service Req LED glows red All LEDs dark Auto
12. 3 In The Dock When a ToxiRAE 3 is in the AutoRAE Lite s dock it is possible to gather data from the ToxiRAE 3 via the AutoRAE Lite Utility Program Start the AutoRAE Lite Utility Program Turn on a ToxiRAE 3 Press and hold Y until you see Ir Place the ToxiRAE 3 into the AutoRAE Lite s dock At the menu bar pull down Operation and select Get Configurations ee be As the connection is being made and the AutoRAE Lite configuration data is transferred a succession of three animated progress pop up windows is shown Get Tester Information 0 Get Monitor Information 50 Get Sensor Information 36 DW wait for a moment A Wait for a moment Wait for a moment Ce The main screen is populated with data and now includes icons of the ToxiRAE 3 and its sensor in the left pane along with the ToxiRAE 3 s serial number AutoRAE Lite Utility Program GFE E E D zo AutorAE Lite T011003703 Eu E ToxiRAE 3 60122717R3 um 23 AutoRAE Lite User s Guide The other panes are populated with data about the AutoRAE Lite Instrument Hame AutoRAE Lite Serial Number 1811903703 Firmware Uersion U1 38 Working Status Normal Power Status External Power Cal If Bump Fails Yes Clock from PC Yes Location Gas Lot Hn 588046080606 0000000000 Note When the AutoRAE Lite is running on its charger with an AC power source External
13. AutoRAE Lite User s Guide RAr 2 l TT q 3 Ll 3 lt Rev C June 2014 P N T01 4007 000 Copyright 2014 RAE Systems Inc AutoRAE Lite User s Guide Contents L EEN 2 SEI Eet EE 3 2 Mounting The AutoRAE Lite On A Wall ccsccsscsssssssosssscscccsncscssessvsevessssoosscsccccnecccsssscceeeessssooss 4 5 Powering IheAutoR Eeer 5 IE E le EE 5 32 Battery FOWE eioen a 5 4 Connecting Calibration Gas ee 6 MEE E TE 6 6 Srel 7 7 B mp lesung QC ali ran iiaeaa a a a A E a A AAA ANa 9 FA Status LED BXpl ndtlOn EE 10 8 Transterrmy E seen etin dr roe tent retient eae 11 8 1 Transferring Data From The SD Card To A Computer 11 6 2 Alter Pransterine Data Prom he SD C ard c e en nement 14 9 Using AutoRAE Lite With The AutoRAE Lite Utility Program cccccccssssccccssssssssssees 15 9 1 Computer Setup And AutoRAE Lite Utility Program Installation cesses 15 9 2 Configuring The Port For The AutoRAE Lite Utility Program 17 9 5 AULORAE Lite U lity Program User Interfaceznu ete ne p ER e 19 IN Mena E MNT 20 0152 Ke e de REOR DU cT 2 9 4 Using The AutoRAE Lite Utility Program In User Mode 21 QAI WithoutA ToxtRAE 3 In The DOCK dno na M eine 21 942 WIKA TOURAE 3T The DOCK msn minerai 23 9 4 3 Getting Events Data From A ToxiRAE 3 25 925 paving Confpuradom esse ane o RR D p nM n e 28 95T Savin A Toxus Ab 3 Comm Cura OTI us oerte natale tern
14. Cal LEDs glow green If no SD card is in the slot the AutoRAE Lite s Service Request LED glows red Service Req LED glows red N Service Req Bump and Cal LEDs go dark D Bump ca AutoRAE Lite User s Guide If the SD card is locked the Service Request LED glows orange and blinks The AutoRAE Lite cannot write data to a locked SD card Remove the SD card and unlock it by moving the lock tab then reinsert the SD card Lock Tab Lock Tab Unlocked SD Card Locked SD Card If remaining space for data on the SD card is very low the Service Request LED glows orange and blinks or glows red continuously Replace the SD card with another with more space on it or offload the data to a computer Then erase the data from the card using your computer and reinsert the SD card back into the AutoRAE Lite IMPORTANT Keep SD port cover closed whenever an SD card is not being inserted or removed This helps to keep the reading mechanism and the SD card clean especially in dusty environments Keep SD cards and the lower portion of the AutoRAE Lite away from magnets Magnets can corrupt the data on an SD card AutoRAE Lite User s Guide 7 Bump Testing amp Calibration Before using the AutoRAE Lite do the following checkout e Make sure the calibration gas cylinder is attached and that the pressure gauge reads gt 50 psi e Make sure the power LED is glowing green e Make sure the air inlet is not
15. N e 380mm 15 additional clearance IMPORTANT for 58L cylinder Allow sufficient clearance around the AutoRAE Lite to accommodate the calibration gas cylinder quickstart card and access to batteries Total clearance width 525mm 21 Total clearance height 702mm 27 75 AutoRAE Lite User s Guide 3 Powering The AutoRAE Lite The AutoRAE Lite can be powered by its AC adapter or by four C size alkaline batteries 3 1 AC Adapter Power The jack for the AC adapter connection is in the recess on the underside of the AutoRAE Lite Location of jack for external AC adapter connection pon from AC adapter plugs into recessed jack Underside of AutoRAE Lite Caution Never use the AutoRAE Lite or its AC adapter in wet or damp environments Do not use outdoors in unprotected locations 3 2 Battery Power You may use four C size batteries instead of the AC adapter Always use high quality alkaline batteries The battery compartment is located on the end of the AutoRAE Lite Open and remove the door by pulling up on the latch and lifting When inserting the batteries be sure to follow the polarity markings indicated in the compartment After all four batteries are installed replace the cover Important Rechargeable batteries can be used instead of alkaline batteries but they cannot be recharged by the AutoRAE Lite They must be recharged in an external charger L3 Pul
16. Power is shown in the box next to Power If the AutoRAE Lite is running on its batteries a battery level bar is shown which indicates remaining battery life 24 AutoRAE Lite User s Guide Click on the ToxiRAE 3 s icon or text to change the other two panes data The upper right pane provides a synopsis of the data that was transferred from the ToxiRAE 3 to the AutoRAE Lite Utility Program The lower right pane shows the information in what appears to be an editable format but is grayed out indicating that it is read only To change settings in this pane the AutoRAE Lite Utility Program must be in Administrator Mode AutoRAE Lite Utility Program B BE x File Operation Option View Help CEET B 2 AutoRAE Lite T0110037Q3 Instrument Name ToxiRAE 3 CS ToxiRAE 3 G0122717R3 Serial Number G6122717R3 Ke Firmware Version U2 18 Current Status Normal Shou Sensor Reading Always Socket Index 1 Sensor H2S ppm Enabled Yes Password 111 Sensor Socket Status Information Firmware Ver v2 10 Status Status Normal Date Time 6 9 201 45 20 09 PM Setting SN cor 22717R3 Show Sensor Always Reading C OnAlarm Password 111 Set Get Events Save Events NM 2 9 4 3 Getting Events Data From A ToxiRAE 3 The lower right pane has a section devoted to events information stored in the ToxiRAE 3 This is read only data but it can be im
17. RAE Lite is not receiving power Cannot perform Bump or Calibration but LEDs are glowing normally green Pump does not operate Time date are wrong in Events log or datalog from SD card Bump testing and calibration take more time than usual During data transfer process green LED does not blink but both red and green LEDs blink Reasons Solutions Reasons Solutions Reasons Solutions Reasons Solutions Reasons Solutions Reasons Solutions ToxiRAE 3 is not in Ir mode SD card is not installed SD card has little or no space remaining SD card is damaged SD card is locked LED blinks orange instead of red Place ToxiRAE 3 in Ir mode and press Y Install SD card Clear space on SD card using computer or use new SD card Replace with SD card known to be undamaged Unlock SD card by moving locking tab Loose damaged wire in cable from AC adapter to AutoRAE Lite Damaged defective AC adapter Power source to AC adapter turned off disconnected Dead batteries Check AC adapter wire and connection to AutoRAE lite Replace AC adapter Check that AC power source is connected and turned on Replace batteries Empty calibration gas tank Obstruction between ToxiRAE 3 and dock Defective gauge or obstruction in inlet line Check that calibration tank has sufficient gas it should register gt 50psi Remove ToxiRAE 3 and check that it is clean and that th
18. arameter settings and cable connections and try again Important If the problem persists refer the ToxiRAE 3 to qualified service personnel Do not place it into service 35 AutoRAE Lite User s Guide 9 7 Using Saved Configuration Files Because the AutoRAE Lite Utility allows you to save monitor configurations you can load a monitor configuration from your computer for upload to a ToxiRAE 3 This is especially useful when you want many ToxiRAE 3 monitors to use a single configuration Note You can only load a configuration file if the AutoRAE Lite Utility is in Administrator Mode Once you have provided a password and have entered Administrator Mode you can load a previously saved monitor configuration 1 Under Operation select Load Monitor Configuration Operation Option View Help Setup Port Get Configurations F2 Operation Mode gt Load Monitor Configuration 2 Apop up window labeled Load Monitor Configuration appears Locate a configuration file that you have saved previously It has a mcfg suffix as in tox13 treatmentplantl H2S mcfg Load Monitor Configuration E 6 9 2014 5 15PM File folder Template 6 9 2014 5 15 PM File folder Recyder22 H25 SecondQuarter mcfg 6 3 2014 5 38PM MCFG File 36 AutoRAE Lite User s Guide 3 Click on the name of the configuration file to select it Load Monitor Configuration Look in AutoRAEII Utility Program v E prm
19. ards come pre formatted RAE Systems part number 550 0301 000 IMPORTANT It is a good idea to transfer the data from an SD card at regular intervals Larger amounts of data result in longer times for transferring data 11 1 Checking Whether An SD Card Needs Formatting If the AutoRAE Lite s Service Requested LED blinks orange or if you are using a new SD card for the first time the SD card may need to be formatted The AutoRAE Lite does not automatically format a card because there may be valuable data on the card Therefore you must remove the SD card from the AutoRAE Lite and connect it to a computer so that you can check it and if necessary format it SD cards typically come pre formatted by the manufacturer but for an SD card to operate properly in the AutoRAE Lite it must be formatted for FAT32 a 32 bit file allocation system If the card is formatted for FAT or FAT16 or unformatted it must be formatted for FAT32 41 AutoRAE Lite User s Guide Before using an SD card or checking whether it needs formatting make sure that its lock tab is in the unlocked position Lock Tab Lock Tab Unlocked SD Card Locked SD Card 11 2 Formatting An SD Card WARNING Formatting an SD card erases everything on the card Once an SD card is formatted any contents that were on it cannot be recovered Always make a backup of the data on an SD card before reformatting it 1 Make sure the SD card is not locked 2
20. e dock area is also clean Try a calibration tank known to be full If gauge does not register gauge may be defective or there may be an obstruction in the inlet line Check the filter and line for obstructions and clear them Pump is damaged obstructed or disconnected Check pump wiring clear obstructions or replace pump Time needs to be synchronized on AutoRAE Lite and on ToxiRAE 3 Connect AutoRAE Lite to computer and use AutoRAE Lite Utility program to reset AutoRAE Lite s internal clock If ToxiRAE 3 has wrong time date place ToxiRAE 3 in AutoRAE Lite dock and reset time date There may be too much data stored on the SD card or the SD card may need reformatting Transfer the data from the SD card and then erase or reformat it Reasons There may be too much data stored on SD card Solutions Transfer the data from SD card and then erase or reformat it 47 AutoRAE Lite User s Guide 14 Support To contact the RAE Systems Technical Support Team Monday through Friday 7 00AM to 5 00PM Pacific US Time Phone toll free 1 888 723 4800 Phone 1 408 952 8461 Email tech raesystems com 48 AutoRAE Lite User s Guide 15 RAE Systems By Honeywell Contacts RAE Systems by Honeywell World Headquarters 3775 N First St San Jose CA 95134 1708 USA Phone 1 408 952 8200 Fax 1 408 952 8480 E mail customerserv raesystems com Web Site www raesystems com RAE Systems Europe ApS Kirstin
21. e ratas 28 9 6 Using The AutoRAE Lite Utility Program In Administrator Mode neessesssesooeeeeeesssssssss 20 QUI dqentenme Administrator WOU nis eio es de e m aea teria d 20 2 002 AUIORAE Lite SOLO E 3l LO MEM For di dad ISOren ccc 32 POP TOXIRKAE 5 SeBnsof SEEC er a a EE 34 9 6 5 Configuring Multiple ToxiRAE 3 Monitors ss 35 9 7 Usine Saved Configuration E 36 10 Updating The AutoRAE Lite Firmware eeececsssssssseccecececcccoosscscssccccccceecccosssssssssececcceceecessssssssoe 38 PL Formatting An SD Cards c 41 11 1 Checking Whether An SD Card Needs Formatting cccccccccccccececeeceeeeeeeeesseseeeeeeeeees 4 1122 Formats An SD Cards ted ice epu qn ied i dca a d deci eater ui rub tae 42 12 leren eg 46 Iberi diri pate 47 IPSI dT 48 IS RAE Systems Cona uiii ii Eo e ERE HG o eden ances en eee ad 49 AutoRAE Lite User s Guide WARNINGS Read Before Operating This manual must be carefully read by all individuals who have or will have the responsibility of using maintaining or servicing this product The product will perform as designed only if it is used maintained and serviced in accordance with the manufacturer s instructions Proper Product Disposal At End Of Life arum The Waste Electrical and Electronic Equipment WEEE directi
22. ecycler22 H25 _HrstQuarter mcfg Monitor Configure File mcfa Cancel Instrument Name ToxiRAE 3 Serial Number G6122717R3 Files of type Firmware Version U2 18 Current Status Normal 10 Updating The AutoRAE Lite Firmware New firmware updates occasionally become available for the AutoRAE Lite Once the firmware update is downloaded from the RAE Systems website or from a disc to your computer follow these steps 1 Connect the AutoRAE Lite to the computer using a USB cable 2 Power up the AutoRAE Lite make sure it has batteries in it or has its AC adapter connected and plugged in Note Make sure a ToxiRAE 3 is not in the dock 3 Start the AutoRAE Lite Utility Program by double clicking its icon on the computer s desktop AutoRAE Lite Utility Program 4 When the main program window is shown pull down the Operation menu and select Upgrade Firmware Operation Option View Help Setup Port Get Configurations F2 Operation Mode gt Load Monitor Configuration 38 AutoRAE Lite User s Guide 5 A pop up window appears reminding you to unplug the USB cable when you are done updating the firmware Click OK AutoRAE Lite Utility Program Please unplug the USB cable from the instrument after upgrading its 6 The RAE Programmer 7000 dialog box appears Set the COM port to match your current configuration for example 6 E RAE Programmer 7000 39 AutoRAE Lite User s
23. ehgj 23 A DK 2770 Kastrup Denmark Phone 45 86 52 51 55 Fax 45 86 52 51 77 orders raeeurope com sales raeeurope com service raesystems com Web www raesystems eu RAE Systems UK Ltd D5 Culham Innovation Centre Culham Science Centre Abingdon Oxon OX14 3DB United Kingdom Phone 44 1865408368 Fax 44 1235531119 Mobile 44 7841362693 Email raeuk raeeurope com RAE Systems France ZI des Ayats 679390 MILLERY France Phone 33 4 78 46 16 65 Fax 33 4 78 46 25 98 Email info france raeeurope com Web www raesystems fr RAE BeNeLux BV Rijndal 20 2904 DC Capelle a d IJssel Phone 431 10 4426149 Fax 431 10 4426148 Email info rae nl Web www rae nl 49 AutoRAE Lite User s Guide RAE Systems Spain s l Av Remolar 31 08820 El Prat de Llobregat Spain Phone 34 933 788 352 Fax 34 933 788 353 Mobile 34 687 491 106 Email mdelgado raespain com Web www raespain com RAE Systems Germany GmbH Felix Wankel Str 5 82152 Krailing Germany Phone 49 89 20 70 40 248 Fax 49 89 850 93 74 Email orders raeeurope com RAE Systems Middle East 10 12 WH 1 High Bay Dubai Silicon Oasis Dubai United Arab Emirates Phone 97 143424344 Fax 97143424330 Email mesales raesystems com RAE Systems Hong Kong Ltd Room 8 6 F Hong Leong Plaza 33 Lok Yip Road Fanling N T Hong Kong Phone 852 2669 0828 Fax 852 2669 0803 Email hksales raesystems com RAE Systems Japan 403 Pla
24. he number of alarm events that have taken place in the ToxiRAE 3 Therefore the list can range from 0 no events to 10 events Click on the sensor s icon or name in the left pane to change the other two panes data The upper right pane provides a synopsis of the data about the sensor that was transferred from the ToxiRAE 3 to the AutoRAE Lite Utility Program Included are the last calibration date and the date when calibration is due 9 4 4 Saving Events From A ToxiRAE 3 Once the events are viewable in the bottom right pane you can save them in Microsoft Excel spreadsheet xls format Click Save Events and then find a location to put your file Name it and click Save The file can be opened in Excel and edited or exported from there into other formats 26 AutoRAE Lite User s Guide It also shows the alarm level settings and the calibration span concentration The lower right pane shows the information in an editable format but is grayed out indicating that it is read only To change settings in this pane the AutoRAE Lite Utility Program must be in Administrator Mode Sensor Name H25 Calibration Date 0 26 2614 18 38 88 AH Cal Due Date 1171972 014 Cal Interval 180 days Bump Date 6 9 2014 11 39 88 AH Bump Interval B days Alarm Levels High 15 8 ppm Low 18 8 ppm STEL 15 8 ppm TWA 16 8 ppm Calibration Span 25 8 ppm 27 AutoRAE Lite User s Guide 9 5 Saving Configuration Files You ca
25. ht click with your mouse and select Delete 14 AutoRAE Lite User s Guide 9 Using AutoRAE Lite With The AutoRAE Lite Utility Program When connected to a computer with a USB cable the AutoRAE Lite s parameters can be viewed In Administrator Mode parameters can be changed These include synchronizing the AutoR AE Lues time to match the computer s clock In addition the AutoRAE Lite Utility Program allows you to view the parameters set for a ToxiRAE 3 when it is placed in the AutoRAE Lite s dock In Administrator Mode it is possible to store and load configuration files This allows you to save one set of parameters and load them into as many ToxiRAE 3 monitors as you want 9 1 Computer Setup And AutoRAE Lite Utility Program Installation 1 Install the USB driver following the instructions on the RAE Systems website or on the utilities disc that accompanies your AutoR AE Lite 2 Install the AutoRAE Lite Utility Program on your computer Follow the instructions after downloading the program from the RAE Systems website or after you insert the disc into your computer Once installation is complete there should be an icon for it on your desktop indicating that the program is ready for use AutoRAE Lite Utility Program 3 Connect the AutoRAE Lite to a computer using a USB cable 4 Configure your computer s port Follow this path Start gt gt Control Panel gt gt System gt gt Device Manager You should see a lis
26. l up 1 Push up on tab 2 on door a i k Md L 3 Remove door Place 4 C size batteries inside AutoRAE Lite User s Guide 4 Connecting Calibration Gas Installing a cylinder of calibration gas is a simple operation Place the cylinder in the gas cylinder dock and then turn it clockwise until it is snug Once the cylinder is attached the gauge should immediately give a reading The reading should be equal to or greater than 50 psi approximately 345 kPa or 3 45 bar If the reading is lower then the tank may not have sufficient contents When it is empty or calibration cannot be performed due to low pressure it should be replaced f Be JL l D L oS e y mi Cylinder in place 1 Insert calibration 2 Screw tighten gas cylinder cylinder in place Note The AutoRAE Lite is designed to accommodate a 58L cylinder of calibration gas It can also accommodate a 34L cylinder but an adapter sleeve is recommended in order to keep the cylinder securely docked in the AutoRAE Lite 5 Air Filter In order to ensure that fresh air is uncontaminated by dust or other materials use a filter on the AutoRAE Lite s fresh air inlet The inlet is located on the bottom of the AutoRAE Lite to the left of the USB and SD card ports The filter s part number is 002 3022 000 sold in packs of 5 part number 002 3022 005 with 5 metal
27. moment Wait for a moment C eai The main screen is populated with data and now includes icons of the AutoRAE Lite the ToxiRAE 3 and its sensor in the left pane along with the AutoRAE Lite s and ToxiRAE 3 s serial numbers 30 AutoRAE Lite User s Guide 9 6 2 AutoRAE Lite Screen AutoRAE Lite Utility Program File Operation Option View Help BFE Cone AR AutoRAE Lite T0110037Q3 Elcg ToxiRAE 3 G0122717R3 E H25 The other panes are populated with data about the AutoRAE Lite Unlike User Mode Administrator Mode now shows the lower right pane in an editable form You can now edit Gas Lot No Gas Lot number as shown on the side of a gas cylinder Clock From PC Synchronize the clock in the AutoRAE Lite to the PC s time Cal If Bump Fails Tell AutoRAE Lite to perform a calibration if a bump test fails In addition you can click Set to set these parameter changes in the AutoRAE Lite AutoRAE Lite Utility Program i DL x File Operation Option View Help eo be i B oo AutoRAE Lite T0110037Q3 Instrument Name AutoRAE Lite E A ToxiRAE 3 G0122717R3 Serial Number 1611893703 H25 Firmware Version U1 38 Working Status Normal Power Status External Power Cal If Bump Fails Clock from PC Location Gas Lot No 6666666666 r Information Gas Lot Setting Firmware Ver Ivi 3 Gas Lot No 0000000000 r Status Status Normal Power External Power
28. n Operation and select Setup Port Operation Option View Help E Get Configurations Operation Mode b Load Monitor Configuration Upgrade Firmware 17 AutoRAE Lite User s Guide The COM port may be selected already Otherwise click the COM 5 256 button with your mouse Type in the COM port setting you found when you went into the computer s System Properties COM port on PC O coM3 COM 5 255 COMGE ei Click OK Note If there is a problem you will see this message RaeSerialPort x Can not open port COM6 Double check your COM port choice Also make sure the USB cable is connected to the AutoRAE Lite and that the AutoRAE Lite is turned on If there are no problems and the port is correctly configured the COM port dialog box automatically closes 18 AutoRAE Lite User s Guide 9 3 AutoRAE Lite Utility Program User Interface The AutoRAE Lite Utility Program can be used to check and configure the AutoRAE Lite or the AutoRAE Lite and a ToxiRAE 3 monitor The program s screen consists of a menu bar toolbar and a left selection navigation pane and two right information panes for synopsis and information In addition when the program is in Admin istrator Mode the lower right pane becomes an interface for setting parameters in a ToxiRAE 3 At the bottom of the screen is a Status Bar which tells when the program 1s ready File Operation Option View Hel
29. n save a configuration file for the AutoRAE Lite and for the ToxiRAE3 which includes all current settings as shown in the right data panes 9 5 1 Saving A ToxiRAE 3 Configuration 1 Click on the ToxiRAE 3 icon in the left pane 2 Pull down the File menu and click Save AutoRAE Lite Utility Program File Operation Option View Help Ctrl4 S Print Gtri P Print Preview Print Setup Exit 3 When the Save As dialog box appears find a location where you want to save the Monitor Configuration File 4 Name the file it automatically gets a mcfg suffix X Save in en T AutoRAE Lite Utility Program Qr ri qua aa ere Template 6 9 20145 15PM File folder File name Becycler 22 H25 Second Quarter Save as type Monitor Configure File mcfg D as 5 Click Save The file is saved and the dialog box closes Note Although you can store a configuration file you cannot load a configuration file unless the AutoRAE Lite Utility is set for Administrator Mode 28 AutoRAE Lite User s Guide 9 6 Using The AutoRAE Lite Utility Program In Administrator Mode Administrator Mode allows you to load configurations from configuration files into the AutoRAE Lite and ToxiRAE 3 monitors It also allows you to change settings and synchronize an AutoRAE Lite s time to a computer 9 6 1 Entering Administrator Mode After you start the AutoRAE Lite Utility Program you
30. nds on the number of alarm events that have taken place in the ToxiRAE 3 Therefore the list can range from 0 no events to 10 events 9 6 3 2 Saving Events Data From A ToxiRAE 3 Once the events are visible in the bottom right pane you can save them in an Excel spreadsheet xls format Click Save Events and then find a location to put your file Name it and click Save The file can be opened in Excel and edited or exported to other formats from there 33 AutoRAE Lite User s Guide 9 6 4 ToxiRAE 3 Sensor Screen Click on the sensor icon for example H2S or its text in the left pane and the lower right pane now shows its editable functions that affect a ToxiRAE 3 in the AutoRAE Lite s dock These include Calibration Dates amp Interval Shows the calibration date and due date and sets the number of days interval until the monitor requires calibration Bump Date amp Interval Shows the bump date and sets the bump interval Alarm Levels Sets the threshold concentrations at which the High Low STEL and TWA alarms sound refer to the ToxiRAE 3 User s Guide for further explanation Calibration Span Concentration of gas used for calibration Click Set to store the parameter changes in any ToxiRAE 3 that is in the AutoRAE Lues dock Important If you do make parameter changes on the screen but do not click Set the changes are not transferred to the ToxiRAE 3 ioj xj File Operation Option Vie
31. ocessing program such as Microsoft Word You should open them as soon as possible to make sure that all of the data transferred properly and was not corrupted You can place the SD card back into the AutoRAE Lite and resume collecting data from bump tests and calibrations New files will not overwrite old ones If the SD card is full or you want to retain it as a physical archive for future reference or backup you can replace it with any SD card Typically IGB is a good minimum size When keeping an SD card for longterm storage it is a good idea to lock the card move the tab on the left side of the card to the locked position This ensures that if it is put into a computer or AutoRAE Lite data cannot be written to it Another option is to erase the SD card To erase the data follow these steps 1 Make sure the locking tab on the SD card is in the unlocked position Insert it into the computer or the adapter and plug that into the computer 3 Once the SD card is in the adapter and connected to the computer it should show up as an external device or a drive 4 Double click the Computer icon on your desktop T Computer 5 When it opens you should see a list of drives including your C and the SD card shown as a device 6 Double click on the name of the device to open its directory You now see a list containing files 7 Select and drag all the files to the trash Alternatively you can select the files rig
32. ort SD Card port cover SD Card port Bottom View showing ports AutoRAE Lite User s Guide Standard Kit The AutoRAE Lite is shipped with the following AutoRAE Lite as specified P N T01 0901 000 USB cable for PC connection P N 410 0086 000 12 volt power supply P N 500 0036 100 Demand flow regulator P N 490 0053 000 SDHC memory card P N 550 0301 000 Quick Start Guide P N TO01 0901 000D Inlet filter P N 002 3022 000 CD ROM P N 000 0T01 000 This disc includes e Operation Manual e Drivers e Utility Software Replacement filters are sold in packages of 5 P N 002 3022 005 AutoRAE Lite User s Guide 2 Mounting The AutoRAE Lite On A Wall The AutoRAE Lite can be used on a flat surface or it can be mounted on a wall This requires drilling four holes into the wall and inserting screws to hold the AutoRAE Lite Important Make sure the wall is strong enough to support the weight of the AutoRAE Lite and a cylinder of calibration gas If necessary mount a piece of plywood or use other reinforcement for the wall Note This diagram is not a full scale template It is only intended to provide measurements for drilling and clearances 375mm wide 14 8 87mm 3 5 additional clearance for battery door 175mm 7 additional NOTE clearance for Screw heads for quickstart card 310 mm 12 2 mounting should not exceed 14 5 mm in diameter E N N c AES u e D e E E N v
33. p Menu bar deen el cy Ee e 9 Tool bar AutoRAE Lite Utility Program anl xl File Operation Option View Bip fa bd 5 Synopsis of settings Selection Navigation Information Parameter Setting Status bar 19 AutoRAE Lite User s Guide 9 3 1 Menu Bar File Operation Option View Help The menu bar consists of five pull down menus e File Operation Option e View Help File The File menu includes e Save Save the current file Print Print the synopsis information Print Preview View the page to be printed before printing it Print Setup Standard choices for setting the page s parameters for printing e Exit Exit the AutoRAE Lite Utility Program Operation These are functions for communication and controlling the AutoRAE Lite s and ToxiRAE 3 s parameters e Setup Port Set the COM communication port Get Configurations Open saved configurations in the program window Operation Mode Go to User Mode or Administrator Mode e Load Monitor Configuration Open a ToxiRAE 3 configuration file Upgrade Firmware Upgrade the AutoRAE Lite s firmware Option This provides a submenu that includes language which allows you to choose a language in which to operate Language Select a language for the program View Make the Tool Bar and Status Bar viewable or hidden e Toolbar e Status Bar Help This is information to aid in using the AutoRAE Lite About AutoRAE Lite Utility Program Display
34. ply want to reformat the disk follow the steps outlined below as if it were a new disk or one that is formatted for another file system 7 Click OK to close the dialog box 8 Right click on Format 43 AutoRAE Lite User s Guide Open Explore Search AutoPlay Scan for Viruses Sharing and Security Open as Portable Media Device ty Combine supported files in Acrobat Eject Cut Copy Create Shortcut Rename lt Properties 9 Under File System select FAT 32 Format Removable Disk F af Capacity 968 MB File system FAT Default allocation size Volume label Format options Quick Format Enable Compression Create an MS DOS startup disk Led 10 Click Start It does not matter whether you select Quick Format so leave it unchecked 11 A pop up window warns you that everything on the disk will be erased during formatting If you do not want to continue with the formatting operation click Cancel Otherwise click OK 44 AutoRAE Lite User s Guide Format Removable Disk F WARNING Formatting will erase ALL data on this disk To format the disk click OK To quit click CANCEL 12 Formatting should take less than one minute When the operation is complete you see this message Formatting Removable Disk F E O6 j Format Complete 13 Click OK The SD card can now be
35. ported to the computer To import the events information click Get Events As the information 1s collected you see this pop up window Get Event Information 33 T Wait for a moment 25 AutoRAE Lite User s Guide The information is organized in an index of events with sensor type date time type of event and reading E AutoRAE Lite Utility Program File Operation Option View Help amp 5 9 9 E AutoRAE Lite T0110037Q3 Ci ToxiRAE 3 G0122717R3 H25 Instrument Name ToxiRAE 3 Serial Number G6122717R3 U2 18 Firmware Version Normal Always Current Status Show Sensor Reading Socket Index 1 Sensor H2S ppm Enabled Yes Paccnuord 111 Information Firmware Ver v2 1 0 Status Status Normal Date Time 5 23 2014 3 35 48 PM Setting SN macau Show Sensor Always Reading On Alarm Sensor Socket Status Events Index Sensor Date Time Event Reading 1 H2S 2014 05 23 14 31 34 BUMP EXPIRE 0 0 ppm H2S 2014 05 23 13 17 57 BUMP EXPIRE 0 0 ppm H2S 2014 05 20 09 38 34 BUMP EXPIRE 0 0 ppm H2S 2014 05 20 08 15 14 BUMP EXPIRE 0 0 ppm H2S 2014 05 1402 58 53 BUMP EXPIRE 0 0 ppm H2S 2014 05 09 06 11 02 HIGH 25 2 ppm H2S 2014 05 09 05 51 13 BUMP_EXPIRE 0 0 ppm LA WINN 3101 NANN UTU 2n Nimmen Password 111 Set Ready Wal 4 The number of events indexed depends on t
36. s program s version number Help Window pops up with assistance 20 AutoRAE Lite User s Guide 9 3 2 Toolbar i de m 2 The toolbar consists of six clickable icons from left to right e RECV Get Configurations e Save The Active Document e Print The Active Document e Load Monitor Configuration Administrator Mode only e Upgrade Firmware e Display Program Information These icons are duplicates of major functions in the menu bar If the menu bar is turned off these provide quick convenient way to activate major functions Note that the Configuration icon is not functional in User Mode and is therefore grayed out 9 4 Using The AutoRAE Lite Utility Program In User Mode The AutoRAE Lite Utility Program operates in two modes User Mode and Administrator Mode In both modes it can be used to check the AutoRAE Lite or the AutoRAE Lite and a ToxiRAE 3 monitor In Administrator Mode settings for the AutoRAE Lite and ToxiRAE 3 can be set 9 4 1 Without A ToxiRAE 3 In The Dock With the main window open pull down Operation and select Get Configurations Operation Option View Help Setup Port Get Configurations Operation Mode Load Monitor Configuration Upgrade Firmware 21 AutoRAE Lite User s Guide As the connection is being made and the AutoRAE Lite configuration data 1s transferred an animated pop up window with a progress bar is shown Get Tester Information 0 Wait for a moment
37. t of devices in and attached to your computer 5 Scroll down the list until you see Ports 15 AutoRAE Lite User s Guide 6 Open Ports click on the to the left of it and you should see the port for the AutoRAE Lite plus its port number for example COMO Write down this port number you will need it when you start AutoRAE Lite Utility Program 5 Device Manager File Action View Help m S 9 A RA ze Disk drives Display adapters DVD CD ROM drives gy Human Interface Devices IDE ATA ATAPI controllers 38 Imaging devices d i Infrared devices Keyboards Mice and other pointing devices D Modems Monitors 3 Network adapters B PCMCIA adapters Y Ports COM amp LPT R ACP210x USB to UART Bridge Controller COM6 8f Processors x Sound video and game controllers System devices CA linksaresl Carisl Que cantrallare 7 Close Device Manager and System Properties 8 Double click the AutoRAE Lite Utility Program icon on your desktop to start the program 16 AutoRAE Lite User s Guide 9 2 Configuring The Port For The AutoRAE Lite Utility Program Before configuring your computer s port make sure the AutoRAE Lite is on and that the USB cable between it and the computer is connected Double click the AutoRAE Lite Utility Program icon on your desktop to start the program AutoRAE Lite Utility Program Pull dow
38. toRAE Lite and connecting it to a compute for data transfer Pry up the corner of Press the the protective cover card and and open it release it USB 4 Place the SD After the card ejects da e ii B pull it out of the slot Slug it into the USB port of a computer WARNING Do not remove the SD card from the AutoRAE Lite during a bump test or calibration After the two LEDs above the buttons glow green it is safe to remove the SD card 11 AutoRAE Lite User s Guide Once the SD card is in the adapter and connected to the computer it should show up as an external device or a drive 1 Double click the Computer icon on your desktop When it opens you should see a list of drives including your C where most programs reside and the external device holding the SD card 2 Pe Devices with Removable Storage 2 cid DVD RW Drive D SD Card E 12 AutoRAE Lite User s Guide 3 You now see three folders containing files created each time the AutoRAE Lite was turned off or the SD card was inserted BB TOXRAES 101 x g u Computer SD Card E TOXIRAE3 3 Search TOXIRAE3 ye File Edit View Tools Help Organize Sharewith e Burn New folder Ex EN sir Favorites Name Date modified Type BE Desktop J BUMPTEST File folder Downloads A CAL DATA File folder 2 Dropbox L EVENT File folder S Recent Places La Libraries Ee Documents
39. ve 2002 96 EC is N21 intended to promote recycling of electrical and electronic equipment and their X components at end of life This symbol crossed out wheeled bin indicates separate O collection of waste electrical and electronic equipment in the EU countries This product may contain one or more Nickel metal hydride NiMH Lithium ion or Alkaline a batteries Specific battery information is given in this user guide Batteries must be recycled or disposed of properly At the end of its life this product must undergo separate collection and recycling from general or household waste Please use the return and collection system available in your country for the disposal of this product Make Sure Firmware Is Up To Date For best operation make sure your monitors and AutoRAE Lite are running the latest firmware AutoRAE Lite User s Guide 1 Overview The AutoRAE Lite is an automated bump testing calibration station designed for performing bump tests and calibration of ToxiRAE 3 monitors It can be used on a tabletop or other flat surface or mounted on a wall Wall mounting instructions are included in this guide In addition it can be powered by either an AC adapter or four alkaline C cell batteries Status LEDs Calibration gas gauge Instrument dock sl Lat Bump and calibration activation buttons and function indicator LEDs Gas cylinder dock Front View gas cylinder removed Air inlet USB p
40. very low Whenever a bump test or calibration is performed the buzzer and LEDs on the ToxiRAE 3 are tested If the instrument passes the tests for the buzzer and LEDs then there is no special indication However if either the buzzer or LEDs test fails the Bump LED glows green and the Service LED glows red 10 AutoRAE Lite User s Guide 8 Transferring Data Bump test and calibration data is collected each time a ToxiRAE 3 is bump tested or calibrated The AutoRAE Lite collects this data and event data and stores it on an SD Card providing a convenient means of storage and easy data transfer 8 1 Transferring Data From The SD Card To A Computer The data stored on the SD card in the AutoRAE Lite is in standard ASCII text format making it easy to import into most spreadsheet and word processing programs In addition it is in CSV comma separated value form so that it can be easily put into existing spreadsheets such as Microsoft Excel or into columns in word processing programs Important In order for AutoRAE Lite to work correctly it is recommended that you clear the SD card s 30 days maximum Some computers and external hard drives have ports that accept SD cards directly For computers that do not have an SD port inexpensive converters designed to accept an SD card and plug into a USB input are widely available at electronics stores camera stores etc Follow this procedure for removing the SD card from the Au
41. w Help 5 l amp RI SI AutoRAE Lite T0110037Q3 Sensor Name H2S 2 A ToxiRAE 3 G0122717R3 H2S Calibration Date 5 26 2614 18 38 88 AH Cal Due Date 11 19 2614 Cal Interval 186 days Bump Date 6 9 2614 11 39 88 AH Bump Interval 6 days Alarm Levels High 15 8 ppm Lou 18 8 ppm STEL 15 6 ppm TWA 16 6 ppm Calibration Span 25 6 ppm Calibration Information Alarm Levels Cal Date 5 20 2014 10 30 00 AM High Cal Due Date 11 19 2014 Cal Interval 180 r Bump Information Calibration Parameters Bump Date 6 9 2014 11 39 00 AM Cal Span 25 0 Bump Interval fo days 34 AutoRAE Lite User s Guide 9 6 5 Configuring Multiple ToxiRAE 3 Monitors With the AutoRAE Lite Utility Program in Administrator Mode you can set new parameters in as many ToxiRAE 3 monitors as you want allowing uniform configuration of many ToxiRAE 3 monitors 1 Place a ToxiRAE 3 in the dock 2 Click Set Parameters are transferred to the ToxiRAE 3 automatically 3 Remove the ToxiRAE 3 4 Place another ToxiRAE 3 in the dock 5 Press Set 6 If the parameters are successfully transferred you see this dialog box Repeat this process as many times as you want Note If there is an error in the data transfer to any ToxiRAE 3 you see this message AutoRAE Lite Utility Program xj A Set Parameter Fails Check the p
42. za Ochanomizu Bldg 2 1 Surugadai Kanda Chiyoda Ku Tokyo Japan Phone 81 3 5283 3268 Fax 81 3 5283 3275 Email jpsales raesystems com RAE Systems Korea 1010 DaeMyungAns Vill First Sang Dong 412 2 Wonmi Gu Bucheon Kyungki Do Korea Phone 82 32 328 7123 Fax 82 32 328 7127 Email krsales 2 raesystems com 50 TE r M S Y y Ho Il CS o eyw lt D RAE Systems by Honeywell World Headquarters 3775 N First St oan Jose CA 95134 1708 USA Phone 408 952 8200 Toll Free 888 723 4800 Fax 408 952 8480 E mail sales support raesales raesystems com E mail technical support tech raesystems com Web Site www raesystems com RAE Systems Europe Kirstinehaj 23A DK 2770 Kastrup Denmark Tel 45 8652 5155 Fax 45 8652 5177 RAE Systems Hong Kong Ltd Units 1516 18 15 F Delta House 3 On Yiu Street Shatin N T Hong Kong Web www raesystems cn Email asiasales raesystems com Phone 852 2669 0828 RAE Systems Middle East 10 12 WH 1 High Bay Dubai Silicon Oasis Dubai United Arab Emirates Email mesales raesystems com Phone 497143424344 Fax 497143424330 P N T01 4007 000 Rev C June 2014