1. T NIN A AI ransio n A TCC 120 J RS 422 485 tee Ne A Repeater MS Y R D R D Q E o YN 14
2. include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes are incorporated into new editions of the publication Technical Support Contact Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Table of Contents 3 EN CIOQUCTION cae A A O ego GC on a o apdo Ao AA ODE DT Built in RS 485 ADDC Intelligence oooncccnnncnnonononans PS Ole COM aia ta cutee ata PS EE E terete eE Reverse Power Protection ccccscecssuuesuuesueueeuusnanenaues DIP Switch Selectable Terminator cccsccceceeeeeeeeueenees Auto Baudrate Detection a wild eevee Dadas Product Features gues ee ai ea asma AEAT AA DA is Package EneckliStana adn PEOCUCES PECINICA LO Set DAA ATA Product VIEWS iras dato tia DEA RIA PED INGICAtONS cie la a ii a altell TASA MAIN Hardware Installation ii ee a 1 Introduction The TCC 120 and TCC 1201 are RS 422 485 isolated repeaters and the TCC 1201 comes with 2 KV isolation protection The following topics are covered in this chapter O 0000 Overview Introduction Built in RS 485 ADDC Intellig
3. wires xa from each of the TCC 120 1201 s SGND RS 422 485 terminal blocks to the opposite connections Connect from R D to Tx from R D toTx from T to Rx from T to Rx and from SGND to SGND 12 STEP 4 Test the Connection After setting the DIP Switches connecting the power and wiring the terminal block we suggest using a Console Terminal program such as HyperTerminal or Moxa Terminal Emulator to test the connection If you have an RS 422 485 serial board such as Moxa Industio CP 132 installed on your PC you can connect your PC s COM port to one of the TCC 120 120I s RS 422 485 terminal blocks and connect the TCC 120 120I s other RS 422 485 terminal block to one of the RS 422 485 serial board s ports Next start HyperTerminal or Moxa Terminal Emulator and then open a connection to the COM port and to the port associated with the TCC 120 1201 s RS 422 485 port Simply type a few characters on your PC s keyboard The characters you type should show up in the HyperTerminal window that is currently inactive indicating that the typed characters were transmitted between the TCC 120 120I s two RS 422 485 ports STEP 5 Placement In addition to placing the TCC 120 1201 on a desktop or other horizontal surface you may also make use of the DIN Rail or wall mount options as illustrated here DIN Rail Wall Mount 3 I Yj gt OH a fF E EN O e O MOXA Q PWR v UY 3
4. Moxa TCC 120 1201 User s Guide Ninth Edition March 2011 Your authorized MOXA Distributor EE EO EE ET EE EE EE ESO svsterra computer GmbH Kreuzberger Ring 22 SYS te r r a D 65205 Wiesbaden Tel 49 0 611 9748 555 comp ut er eMail moxa systerra de http www systerra de www moxa com product MOXA 2011 Moxa Inc All rights reserved P N 1802001200302 Moxa TCC 120 120I User s Guide The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice O 2011 Moxa Inc All rights reserved Trademarks The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might
5. Power and Signal TCC 1201 20 to 60 C 20 to 85 C 5 to 95 RH External 12 48 VDC Power Terminal Block Protects against V V reversal Protects against 2 signals shorted together TCC 120 TCC 120I 65mA 12V 180mA 12V 37MA 24V 90mA 24V 26mA O 48V 52mA O 48V 67 x 100 x 22 mm casing only 90 x 100 x 22 mm including ears Aluminum 22 16 AWG Black 14875 g CE FCC Class A UL 60950 1 Product Vievvs Top End Vievv on 123 Le Top Panel View Side View Transi Qn 4 TCC 120 LED Indicators The TCC 120 1201 s top panel contains three LED indicators as described in the table below LED Name LED Function PWR Red indicates the power is on erence Data is entering through the top end port and g exiting through the bottom end port eek Data is entering through the bottom end port and exiting through the top end port 2 Installation This chapter includes information about how to install the TCC 120 120I The following topics are covered in this chapter O Hardware Installation Hardvvare Installation Five steps are required to install the TCC 120 120I e STEP 1 Set the terminator DIP Switches e STEP 2 Attach the Power Supply e STEP 3 Wire the RS 422 485 Terminal Blocks e STEP 4 Test the Connection e STEP 5 Placement The details of each of these five steps are described next STEP 1 Set the DIP Switches The DIP Switches on the TCC 120 120I are used to set t
6. ence Isolation Reverse Power Protection DIP Switch Selectable Terminator Auto Baudrate Detection Product Features Package Checklist Product Specifications Product Views LED Indicators VV VV VV Overview Introduction Many important devices used in today s industrial environment use the RS 422 or RS 485 interface for data transmission In some cases however it is necessary to extend the transmission distance between RS 422 485 devices This is where the TCC 120 1201 RS 422 485 Repeaters come in Simply wire the power terminal block wire the two signal terminal blocks set the DIP switches and you re ready to go The RS 422 485 standards use a differential signal for transmitting data signals In addition to distance and multi drop issues for industrial applications housing wiring power supply and over surge protection are also serious concerns The TCC 120I provides isolation protection for users who need an industrial grade repeater to extend RS 422 485 transmission distance and increase networking capability The superior industrial application design of this product which includes Wall mounting terminal block wiring external terminal block power and optical isolation for system protection makes the TCC 120 120I suitable for use in critical industrial environments Built in RS 485 ADDC Intelligence ADDC Automatic Data Direction Control a Moxa leading technology uses a clever hardware solution to ta
7. he serial signal s baudrate by hardware This is an extremely convenient feature for the user Even if a device s baudrate changes the signal will still be transmitted through the RS 422 485 repeater without any problems Product Features Boost serial signal for extending transmission distance up to an additional 1 2 km Wall or DIN Rail mountable Terminal block for easy wiring Power input from terminal block DIP switch setting for built in terminator 120 ohms PWR Tx Rx LEDs Operating temperature from 20 to 60 C 2 KV Isolation for the TCC 1201 Package Checklist Before installing the TCC 120 120I verify that the package contains the following items Standard Accessories TCC 120 or TCC 1201 User s Guide Warranty Card DIN rail Mounting Kit Please notify your sales representative if any of the above items is missing or damaged Product Specifications Model Names Communication Signals for 2 wire RS 485 2 wire Signals for 4 wire RS 422 or 4 wire RS 485 RS 485 Data Direction Control Baudrate Isolation Environmental Operating Temperature Storage Temperature Humidity Power Input Power Voltage Reverse Power Protection Over Current Protection Power Consumption Mechanical Dimensions W x D x H Housing Plug In Screw Terminal Block Color Weight Regulatory Approvals TCC 120 TCC 1201 Data Data SGND Tx Tx Rx Rx SGND ADDC 50 bps to 921 6 Kbps 2 KV for both
8. he signal transmission mode and to enable or disable the termination resistor You can configure for either 2 wire RS 485 or 4 wire RS 422 485 transmission mode Also note that your program and serial port should be set to match the repeater s settings NOTE The TCC 120 120I has two sets of DIP Switches one set on the top end and the other set on the bottom end To ensure proper data transmission make sure that the two sets of DIP switches are configured SW1 Switch 1 selects RS 422 or RS 485 mode The default is On for RS 422 mode SW2 Switch 2 selects 2 wire or 4 wire RS 485 mode The default is On for 4 wire RS 485 Note that if Switch 1 is set to RS 422 mode then Switch 2 is inactive SVV3 Switch 3 enables the terminator to 120 Ohms When enabled the 120 Ohm resistor prevents signal reflection during RS 485 transmission The default is On to enable the terminator If your particular application does not require the termination resistor simply disable it by setting Switch 3 to the off position Dip Svvitch Settings 4 wire RS 485 Terminator active 2 wire RS 485 Terminator active NOTE These switch settings apply for product revision 1 3 and later for the switch settings of previous product revisions refer to the label on the rear panel for the correct information 10 The newly implemented DIP 2 S3 and S4 switches are used to configure the pull high low resistors for different applica
9. ke care of the RS 485 data flow control problem ADDC is a hardware data flow solution that automatically senses and controls data direction making the handshaking signal method unnecessary Isolation Moxa s electrical isolation technology uses two photo couplers to create a gap in each electrical signal One photo coupler transforms the electrical signal into a light signal which is transmitted across a small gap and then the other photo coupler transforms the light signal back into an electrical signal In this way the two electrical circuits are completely isolated from each other limiting the damage that could otherwise be caused by ground loops in the electrical signal Reverse Power Protection The Reverse Power Protection feature provides extra protection against accidentally connecting the power cables to the wrong terminal The converter is designed to automatically detect which power wire is positive and which is negative and then adjust the power supply accordingly DIP Switch Selectable Terminator For many products of this type the termination resistor is set by a jumper located inside the product s casing so that the user must open the casing to disable or change the resistor s strength Moxa offers a better solution The TCC 120 120I s terminator is set with a DIP Switch located on the outside of the converter s casing Auto Baudrate Detection The TCC 120 1201 incorporates a method for automatically detecting t
10. tions R a Ei Pull High Low Resistor___ DIP 25W1 DIP 2SW2___ 150K 1K default NOTE We recommend setting the pull high low resistor to 1K ON ON when termination is enabled NOTE These switches are for pull high low resistor settings These features are available on product version 1 3 and later 11 STEP 2 Attach the Power Supply The TCC 120 1201 is powered by an external 12 48 VDC power supply To connect to the power supply run two wires from the V and V terminals on the TCC 120 s 3 connector terminal block to the DC power supply as shown in the Power Supply figure on the left 12 48 VDC Once the power supply is connected to its power source the PWR LED located on the TCC 120 s top panel should be illuminated in red NOTE The TCC 120 120I provides reverse power protection It will automatically detect which power wire is negative and which is positive STEP 3 Wire the Terminal Block There are two wiring options available for connecting to the TCC 120 1201 s RS 422 485 terminal block 2 wire When using the 2 wire for Data RS 485 wiring option you will Data need to connect three wires from each of the TCC 120 1201 s RS 422 485 terminal blocks to the SGND opposite connections Connect from R D to Data from R D to Data and from SGND to SGND 4 wire When using the 4 wire for RS 422 Tx or 4 wire RS 485 wiring option Tx you will need to connect five