User's Guide DS1000Z Series Digital Oscilloscope

image

Contents

1. Chapter 13 Store and Recall RIGOL Offset 0U Scale 500 mU Threshold A OV intg Display OFF Source CH1 Offset OU Scale 1 pU diff Display OFF Source CH1 Offset OU Scale 2 MU sqrt Display OFF Source CH1 Offset OU Scale 100 mU Ig Display OFF Source CH1 Offset OU Scale 100 mU In Display OFF Source CH1 Offset OU Scale 100 mU exp Display OFF Source CH1 Offset 0U Scale 100 mU abs Display OFF Source CH1 DS1000Z User s Guide 13 19 RIGOL Chapter 13 Store and Recall Offset 0U Scale 100 mU Protocol Decoding MATH Decode1 Decode2 Decoder Parallel Decode OFF Format ASC Parallel Clock Channel None Edge Rising Edge Width 8 Bit X 0 Channel CH1 RS232 TX CH1 Polarity Baud 9600 RX OFF Endian LSB Data 8 Stop 1 Parity None 12C SCLK CH1 SDA CH2 Address Normal SPI Mode Timeout CLK CH1 MISO OFF MOSI CH2 Edge Rising edge Polarity Timeout 20 us Width 8 Order LSB 13 20 DS1000Z User s Guide Chapter 13 Store and Recall RIGOL Configure Label ON Line ON Format ON Endian ON Width ON Data Src Trace Range Full Reference Waveform Setting REF Channel Setting REF1 Current Channel REF1 Source CH1 Offset 0 uv Scale 200 mV Color Gray DS1000Z User s Guide 13 2
2. Trigger Output Connector When the oscilloscope is triggered a signal that can reflect the current capture rate of the oscilloscope will be outputted via Trigger Out connector and connect the signal to a waveform display instrument to measure the frequency of the signal and the result is equal to the current capture rate Note in the 9 Pass Fail Test when the Aux Out is turned on there will be output a negative pulse signal when failed waveforms are detected by the oscilloscope Connect this signal to other control systems to view the test result conveniently There will be output a 3 3 V CMOS high level when no failed waveform is detected by the oscilloscope DS1000Z User s Guide 5 41 Chapter 6 To Make Measurements RIGOL Chapter 6 To Make Measurements DS1000Z can make math operation cursor measurement and auto measurement on sampled and displayed data The contents of this chapter m Math Operation BH Auto Measurement B Cursor Measurement DS1000Z User s Guide 6 1 RIGOL Chapter 6 To Make Measurements Math Operation DS1000Z can realize various math operations including addition A B subtraction A B multiplication AxB division A B FFT A amp amp B A B A B A intg diff sqrt lg In exp and abs The results of math operation also allows further measurement for details please refer to Cursor Measurement Press MATH gt Math gt O
3. fessure Oscauire storage i Cursor pota ou Measure press this key to open the measurement setting menu You can set the measurement setting all measure statistic function etc Press MENU at the left of the screen to switch the measurement menus of 24 waveform parameters Then press down the corresponding menu softkey to quickly realize one key measurement and the measurement result will be displayed at the DS1000Z User s Guide 1 17 RIGOL Chapter 1 Quick Start bottom of the screen Acquire press this key to enter the sample setting menu to set the acquisition mode Sin x x and memory depth of the oscilloscope Storage press this key to enter file store and recall interface The storable file types include picture traces waveforms setups CSV and parameter Internal and external storage as well as disk management are also supported Cursor press this key to enter cursor measurement menu The oscilloscope provides three cursor modes manual track and auto Display press this key to enter display setting menu to set the display type persistence time wave intensity grid type grid brightness and menu display time of the waveform Utility press this key to enter the system function setting menu to set the system related functions or parameters such as I O setting sound and language Besides some advanced functions such as pass fail test
4. P1 P2 P3 Idle Time lt M Trigger Type Press Type to select Nth Edge At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 as the Trigger Source The current trigger source is displayed at the upper right corner of the screen Note select channel with signal input as trigger source to obtain stable trigger Edge Type Press Slope to select the kind of edge of the input signal on which the oscilloscope triggers e EJ trigger on the rising edge of the input signal when the voltage level meets the specified trigger level e Es trigger on the falling edge of the input signal when the voltage level meets the specified trigger level Idle Time Press Idle to set the idle time before the edge counting in Nth egde trigger The range available is from 16 ns to 10 s 5 32 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Edge Number Press Edge to set the value of N in Nth edge trigger and the range available is from 1to 65535 Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameter noise rejection under this trigger type Trigger Level Use TRIGGER LEVEL to m
5. Host Device SDA SDA SCLK SCLK SCLK SDA SCLK sample the SDA on the clock rising edge or falling edge SDA denote the data channel Press gt Decodel gt Decoder to select RS232 and open the RS232 decoding function menu 1 Press Decode to turn on or off the decoding function Decoding Mode Setting Press Mode to set the decoding mode of SPI you can selected CS or Timeout CS when CS selection is valid the SPI bus samples the data at the jumping point of CLK After selecting this mode press CS to select any channel CH1 CH4 as the CS channel If OFF is selected no CS channel is set Timeout when this trigger condition is selected press Timeout to set the minimum time that the clock SCL signal must be idle before the oscilloscope will search for the data SDA on which to decode The range is from 100 ns to 1 S CLK Setting Press CLK to select any channel CH1 CH4 as the clock channel DS1000Z User s Guide 7 15 RIGOL Chapter 7 Protocol Decoding 4 MISO Setting Press MISO to select any channel CH1 CH4 as the MISO data channel When OFF is selected this data line is not set 5 MOSI Setting Press MOSI to select any channel CH1 CH4 as the MOSI data 6 Edge Setting Press Edge to sample the MISO and MOSI at the rising edge or falling edge of CLK 7 Polarity setting Press Polarity to set the polarity of the SDA data line to the high level
6. 1 6 DS1000Z User s Guide Chapter 1 Quick Start RIGOL To Connect the Probe RIGOL provides passive probes for the DS1000Z series oscilloscopes For detailed technical information of the probes please refer to the corresponding Probe User s Guide The following are the probes recommended for this oscilloscope Model Description RP3300 350 MHz passive probe standard RP3500A 500 MHz passive probe optional Connect the Probe 1 Connect the BNC terminal of the probe to a channel BNC connector of the oscilloscope at the front panel 2 First connect the ground alligator clip of the probe to the circuit ground terminal and then connect the probe tip to the circuit point to be tested Figure 0 5 To Connect the Probe DS1000Z User s Guide 1 7 RIGOL Chapter 1 Quick Start Function I nspection l Press Storage gt Default to restore the instrument to its default configuration 2 Connect the ground alligator clip of the probe to the Ground Terminal under the probe compensation signal output terminal 3 Use the probe to connect the input terminal of CH1 of the oscilloscope and the Compensation Signal Output Terminal of the probe Compensation Signal Output Terminal Ground Terminal Figure 0 6 To Use the Compensation Signal 4 Press AUTO 5 Observe the waveform on the display In normal condition the display should be a square waveform as shown in the figure below Figure
7. 3 Parallel Decoding 2 Channel Label 7 Pattern Setting 17 19 CSV usui de e B e 3 Pattern Trigger 17 CUSO s isto bor tops 29 Peak Detect 4 Delay oc tache ed med 21 Period emet eed ie mete 20 Delay Trigger 30 Persistence Time ssssssse 3 Delayed Sweep 2 Picture s iode ci a aaa 3 DACP isi aaO PES 3 Presnoots i ide pe ee 23 Division sesseeee 4 Pulse Condition 10 Domain Name Server 4 Pulse Trigger 10 DOSa c TE 2 Pulse Width Setting 10 Duration Trigger neee 19 Rectangle nnn 7 Edge Trigger 9 Rise TiME nrnna a 20 Edge Type cse d ens 9 iei peperere assent 8 Factory 3st b Pd bere teens 14 R5232 DECOGING tic ccr ens 5 Fall TIME die S da dte 20 Runt Trigger ccce 25 E E EE A 6 Sample Rate ac 5 Platt pz icc ttr be avai 8 Setup Hold Trigger 21 Frequency reee 20 Setups Le d ed 3 Frequency Counter 24 SING ganire xe rhe Reihe to en 20 7 Gates ide Ru ARE RE Reds 4 Slope Condition ssse 12 Hamriririg t e e ees 7 Slope Trigger ccce 12 Hanning interni b ERO ns 7 SPI Decoding ait 15 DS1000Z User s Guide 1 RIGOL Index Static UP aani ienaa Mahan Ern 3 Vertical Expansion sssse 6 Subnet Mask is eR oboe 4 Vetrtical SCalg ico eerie 5 Substraction 3 Vertical Window sse 13 SYNE a ER rn ERR d 1
8. Chapter 18 Appendix RIGOL Chapter 18 Appendix Appendix A Accessories and Options Descriptions Order Number DS1104Z 100 MHz 4 channel DS1104Z POS 100 MHz 4 channel dual channel DS11047 S Models 25MHz signal source DS1074Z 70 MHz 4 channel DS1074Z acd MHz 4 channel dual channel DS10747 S 25MHz signal source Power Cord conforming to the standard of the country CB USBA USBB B dat Standard VAPORE FF 150 Accessories 4 passive probes 150 MHz RP2200 Quick Guide Resource CD include User s Guide and application software OpHona Rackmount Kit RM DS10002 Accessories M MEM DS1000Z ris 24Mpts single channel 12Mpts P dual channel 6 Mpts four channel Options W REC DS1000Z aveform The option supports waveform record and neron waveform playback Option iod Advanced The option include RS232 UART trigger 12C Trigger trigger SPI trigger Runt trigger Window trigger AT DS1000Z Options Nth edge trigger Delay trigger Timeout trigger Serial Th tion incl RS232 UART 12C SPI Decoding e op ion inc uge 232 U C S SA DS10002 decoding function Options Note all the options or accessories can be ordered from you local RIGOL Office DS1000Z User s Guide RIGOL Chapter 18 Appendix Appendix B Warranty RIGOL warrants that its products mainframe and accessories will be free from defects in materials and workmanship within the warranty period If a product is proven to be defective within the r
9. SDOx SDIx l i gt L i i Serial Data Line Buffer l Serial Data Line Buffer SPIxRXB SPIxRXB i 1 i 1 SDIx SDOx I Shift Register mi Shift Register l i SPIxSR i SPIXSR 1 Highest Bit Lowest Bit Highest Bit Lowest Bit i i Serial Transmission Buffer i Serial Transmission Buffer SPIXTXB I SPIxTXB i if 7 i Serial Clock SPI Buffer SCKx I SCKx SPI Buffer SPIxBUF SPIxBUF MIC ae ARE Ee 1 PERPE GERINGERE E i Trigger Type Press Type to select SPI At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press SCL and SDA to specify the data sources of SCL and SDA respectively They can be set to CH1 CH4 and the current trigger source is displayed at the upper right corner of the screen Trigger Condition Press When to select the desired trigger condition CS trigger when the CS channel is select high level or low level After this DS1000Z User s Guide 5 39 RIGOL Chapter 5 To Trigger the Oscilloscope that CS is valid only when this condition is selected TimeOut set the minimum time that the clock SCL signal must be idle before the oscilloscope starts to search for the data SDA on which to trigger Press TimeOut to set the timeout value and the range is from 100 ns to 1 s Note that at this p
10. Resolution 100 uV or 3 bit select the greater one Accuracy 2 1 kHz General Specifications Probe Compensation Output Output Voltage About 3 V peak peak Frequency 1 kHz Power Power Voltage 100 240 V 45 440 Hz Power Maximum 50 W Fuse 2 A T degree 250 V Environment Temperature In operation 0 C to 50 C Range Out of operation 40 C to 70 C Cooling Method Fan Humidity Range 0 C to 30 C lt 95 relative humidity 35 C to 40 C lt 75 relative humidity 40 C to 50 C lt 45 relative humidity Altitude In operation under 3 000 meters Out of operation under 15 000 meters Mechanical Dimensions WidthxHeightxDepth 2313 1 mmx 160 8 mmx122 4 mm Weight Without package 3 2 kg 0 2 kg With package 3 8 kg 0 5 kg Adjustment I nterval The recommended calibration interval is one year Regulation Standards Electromagnetic 2004 108 EC 17 8 DS1000Z User s Guide Chapter 17 Specifications RIGOL Compatibility Safety Execution standard EN 61326 1 2006 EN 61326 2 1 2006 UL 61010 1 2004 CAN CSA C22 2 NO 61010 1 2004 EN 61010 1 2001 IEC 61010 1 2001 Note Typical Note Maximum value with 50 ns single channel dots display and auto memory depth NoteP Tilt tabs and handle folded knob height included Note Standard configuration DS1000Z User s Guide
11. Rotate amp 2 directly to set the desired implitude value DS1000Z User s Guide 12 9 RIGOL Chapter 12 Signal Source Method two Press 42 to input desired paramrter values and unist directly using the pop up numeric keyboard 5 To set the DC offset voltage Press Offset to set the DC offset of the current signal and the range available is from 2 5 V the amplitude value currently set 2 when the impedance is HighZ to 2 5 V the amplitude value currently set 2 when the impedance is 50 Q Rotate 42 directly to set the desired DC offset value Method two Press 42 to input desired paramrter values and unist directly using the pop up numeric keyboard The offset value is only remained three significant figures For example when the amplitude is set to 10 mV the impedance is 50 Q the offset range calculated is 1 245 V to 1 245 V but the actual offset range is 1 24 V to 1 24 V 6 To set the start phase Press Start Phase to set the start phase of the current signal and the range available is from 0 to 360 Method one Rotate directly to set the desired start phase Method two Press 2 to input desired paramrter values and unist directly using the pop up numeric keyboard 7 Align phase Press AlignPhase to re configration the two channels and enable the signal source to output with specified frequency and phase For two signals whose frequencies are the same or in multiple this operation will align their p
12. BI to stop testing You can select the signal source set the test mask range create mask as well as save and load the test mask For details please refer to the following introductions To Select Source Press Source to select the channel CH1 CH4 to be tested and only channels enabled can be selected During the test the oscilloscope will judge whether each frame of waveform in the source complies with the current test mask and those waveforms pass through the mask area blue area is considered as failed Mask Range Users can define their desired test masks The test mask is Screen by default Press Range to enter the mask range setting menu Press X Mask and Y Mask rotate amp 2 and the mask lines appear on the screen as shown in the figure below Press Create Mask to apply the mask currently created The horizontal and vertical adjustment ranges are 0 02 div to 4 0 div and 0 04 div to 5 12 div respectively 9 2 DS1000Z User s Guide Chapter 9 Pass Fail Test RIGOL Test and Ouput Before the test you can use the following method to set the output mode of the test results Press Stat Disp to select ON or OFF When ON is selected the test results will be displayed at the upper right corner of the screen a Total 94 wfs Press Stat Disp to clear the current statistic and restatistic the test result Press Stop On Fail to select ON or OFF ON when failed waveforms are detecte
13. CH4 Switch ON Channel Coupling DC Bandwidth Limit OFF Probe Ratio 1X 13 14 DS1000Z User s Guide Chapter 13 Store and Recall RIGOL Channel Invert OFF Amplitude Scale Coarse Channel Unit V Acquisition Setting Acquire Acquisition Mode Normal Sin x x OFF Memory Depth Auto Trigger Setting TRI GGER Trigger Type Edge Source CH1 Slope Rising Edge Trigger Mode Auto Trigger Coupling DC Trigger Holdoff 16ns Noise Reject OFF Display Setting Display Display Type Vectors Persistence Time Min Waveform Intensity 50 Screen Grid EH Brightness 50 Signal Source Output OFF Status Display OFF Src1 Setup Wave Sine Output OFF Frequency 100 kHz Amplitude 1 000 V Offset 0 00 V Start Phase 0 00 Modulation OFF DS1000Z User s Guide 13 15 RIGOL Chapter 13 Store and Recall Src2 Setup Wave Sine Output OFF Frequency 100 kHz Amplitude 1 000 V Offset 0 00 V Start Phase 0 00 Modulation OFF Cursor Setting Cursor Mode OFF Manual Cursor Type X Source CH1 Time Unit S CurA 4 1us CurB 4 us Track Cursor A CH1 Cursor B CH1 CurA 4 1 us CurB 4 1 us Storage Setting Storage Storage Type Picture Utility Function Setting Utility I O Setting Network DHCP Auto IP Configuration Mode Sound Sound OFF P
14. Name Input Area Keyboard Upper lower Case Switch 2 During the name input you can press Name to select the Name Input Area and then press Delete to delete the Chinese characters on the left of the cursor one by one 3 After finishing the input press OK and the oscilloscope will create a folder or a specified type of file with this name under the current directory DS1000Z User s Guide 13 11 RIGOL Chapter 13 Store and Recall To Delete a File or Folder Folder operation is valid only in external storage Before using the external disk make sure that the USB storage device is connected correctly 1 Delete a file in internal memory 1 Press Storage gt DiskManage and use to select and open the local disk local Disk 2 Press File Type to select the desired type of file to delete note that the file types of internal storage include stp ref and pf 3 Use 42 to select the desired file to delete 4 Press Delete OK to delete the file selected 2 Delete a file or folder in external memory Press gt DiskManage and use gt to select and open the external disk Disk D Use 2 to select the file or folder to be deleted and then press Delete gt OK to delete the selected file or folder 13 12 DS1000Z User s Guide Chapter 13 Store and Recall RIGOL To Rename a File or Folder Rename operation is valid only in external storage Before using the external disk make sure t
15. Negative Runt Pulse Trigger Type Press Type to select Runt At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 as the Trigger Source The current trigger source is displayed at the upper right corner of the screen Pulse Polarity Press Polarity to select the pulse polarity of runt trigger e lii positive polarity The instrument triggers on the positive runt pulse e M negative polarity The instrument triggers on the negative runt pulse Qualifier Press Qualifier to set the trigger conditions of runt trigger None do not set the trigger condition of runt trigger e gt trigger when the runt pulse width is greater than the lower limit of pulse width Press Lower Limit to set the minimum pulse width of runt trigger The range available is from 8 ns to 10 s DS1000Z User s Guide 5 25 RIGOL Chapter 5 To Trigger the Oscilloscope e lt trigger when the runt pulse width is lower than the upper limit of pulse width Press Upper Limit to set the maximum pulse width of runt trigger The range available is from 8 ns to 10 s lt gt trigger when the runt pulse width is greater than the lower limit and lower than the upper limit of pulse width Press Upper Limit to set the maximum pulse width of runt trigger and the range is from 16 ns to 10 s press Lower Limit to set the minimum pulse widt
16. and To Edit Waveforms To Select Waveform Users can select arbitrary waveforms stored in the interal memory to output Press Select gt Load and use to select desired waveform You also can edit the waveform currently selected and please refer to the instruction of To Edit Waveforms To Create Waveforms Users can create arbitrary waveforms according to their need Press Create to enter the waveform creation interface 1 To set the number of initial points When creating a new waveform the waveform editor will automatically create a waveform with two points By default point 1 is located at 0 s and point 1 is located at half of the specified period Press InitPoint and use 2 to set the initial points of the new waveform and the arbitrary waveform points can be up to 16384 16 kpts 2 Interpolation Press Interp to turn the interpolation between the defined waveform points on or 12 14 DS1000Z User s Guide 3 5 Chapter 12 Signal Source RIGOL off ON the waveform editor will connect the two points with a straight line OFF the waveform editor will hold a constant voltage level between two points and create a step waveform Zoom Press Zoom to turn the zoom function on or off ON only displays the current point in the middle of the waveform editor window OFF displays all the initial points in the waveform editor window Current point Press CurPoint and use to
17. distortion will be generated and the actual circuit must be avoide At this point the output amplitude would not be exceed 5 Vpp the impedance is 50 Q Frequency modulation the frequency of the carrier waveform varies with the amplitude of the modulating waveform Modulating waveform E M Carrier waveform AMAA MERIT WERDE 4 ane Modulated waveform After FM is selected you can set the frequence of the modulating waveform and the FM modulation frequency Frequencey press Frequency to set the frequence of the modulating waveform and the range available is from 1 Hz to 50 kHz For the setting method please refer to the instruction of the To set frequency Deviation press Deviation to set the deviation of modulating waveform frequency relative to the carrier waveform frequency and the range available is from 0 Hz to the carrier waveform frequency currently set 2 To select modulating waveform Press Shape to select Sine Square Ramp and Noise as the modulating waveform 12 20 DS1000Z User s Guide Chapter 13 Store and Recall RIGOL Chapter 13 Store and Recall Users can save the current settings waveforms screen image and parameter of the oscilloscope in internal memory or external USB mass storage device such as USB storage device in various formats and recall the stored traces settings or waveforms when needed The contents of this chapter Storage System Storage Type Internal Stor
18. or Memory as the data source Press Range to select Full or User When Full is selected the instrument will determine the decoding range according to the current selection of the current data source when User is selected press Start to set the start point of the decoding and the range available is from 0 to end point 1 and press End to set the end point of the decoding and the range available is from start point 1 to 1199 7 4 DS1000Z User s Guide Chapter 7 Protocol Decoding RIGOL RS232 Decoding Option RS232 serial bus consists of the transmitting data line TX and the receiving data line RX Rx Tx DeviceA DeviceB Tx Rx The industry standard of RS232 uses Negative Logic namely high level is logic 0 and low level is logic 1 By default RS232 uses LSB Least Significant Bit transmission sequence namely the lowest bit of the data is transmitted first While for MSB Most Significant Bit the highest bit of the data is transmitted first vlv gg v iv w w vlv vlv w wl in PIIRI 8 A 0 602 GIN 5 S t gt t gt Endian LSB Endian MSB In RS232 baud rate is used to represent the transmitting rate namely bits per second of the data The commonly used baud rates include 2400 bps 4800 bps 9600 bps 19200 bps 38400 bps 57600 bps and 115200 bps In
19. signal should use Video trigger Only when the proper trigger type is used can the waveform be displayed stably 3 Check the trigger level adjust the trigger level to the middle position of the signal DS1000Z User s Guide 16 1 RIGOL Chapter 16 Troubleshooting 4 Change the trigger holdoff setting 5 No display after pressing RUN STOP Check if the IMODE at the front panel TRIGGER control area is on Normal or Single and if the trigger level exceeds the waveform range If yes set the trigger level to the middle or set the MODE to Auto Note using AUTO could automatically finish the above setting 6 The display of waveform is ladder like 1 The horizontal time base might be too low Increase the horizontal time base to increase the horizontal resolution and improve the display 2 If Type is Vectors the lines between the sample points may cause ladder like display Set Type to Dots to solve the problem 7 Fail to connect PC through USB 1 Check if the USB data cable is correctly connected to the oscilloscope and PC 2 Check if the USB data is in good condition and if needed restart the oscilloscope 8 The USB disk can not be recognized 1 Check if the USB disk can work normally 2 Make sure that the USB disk being used is flash type This oscilloscope does not support hardware type USB disk 3 Make sure if the capacity of the USB disk is too large It is recommended that
20. storage device in png format Traces Save the waveform data in external memory in trc format The data of all the channels turned on can be saved in the same file At recall the data will be displayed on the screen directly Waveforms Save the waveform data in external memory in wfm format The stored files contain the waveform data of the two analog channels and the main setting information of the oscilloscope and all the data can be recalled Setups Save the settings of the oscilloscope in internal or external memory in stp format The stored settings can be recalled CSV Save the waveform data displayed on the screen or of the specified channels in DS1000Z User s Guide 13 3 RIGOL Chapter 13 Store and Recall external memory in a single csv file You can specify the file name and the saving directory and save the corresponding parameter file txt under the same directory using the same file name the function of this parameter file is the same to the Parameters The recall of CVS and parameter files is not supported After selecting this type Press DataSrc to select Screen or Memory After selecting Memory press Channel to select the desired channel note that only channels currently enabled can be selected Press Param to enable or disable the parameter save function Parameters Save the waveform parameters displayed on the screen in external memory in txt format The parameter
21. to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORI ZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results DS1000Z User s Guide 6 17 RIGOL Chapter 6 To Make Measurements Auto Measurement DS1000Z provides auto measurements of 24 waveform parameters and the statistics and analysis of the measurement results What s more you can also use the frequency counter to realize more precise frequency measurement Quick Measurement after When the oscilloscope is correctly connected and has detected input signal press Auto to enable waveform auto setting function and open the following function menu Single period measure the Period and Frequency of the current signal within a single period and display the
22. 0 7 Square Waveform 6 Usethe same method to test the other channels If the square waveforms actually shown do not match that in the figure above please perform Probe Compensation in the next section WARNI NG AN To avoid electric shock during the use of probe please make sure that the insulated wire of the probe is in good condition and do not touch the metallic part of the probe when the probe is connected to high voltage source 1 8 DS1000Z User s Guide Chapter 1 Quick Start RIGOL Tip The signal output from the probe compensation connector can only be used for robe compensation adjustment and can not be used for calibration DS1000Z User s Guide 1 9 RIGOL Chapter 1 Quick Start Probe Compensation When the probes are used for the first time you should compensate the probes to match the input channels of the oscilloscope Non compensated or poorly compensated probes may cause measurement inaccuracy or error The probe compensation procedures are as follows 1 Perform steps 1 2 3 and 4 of Function Inspection in the previous section 2 Check the waveforms displayed and compare them with the following 3n FLA fun v J ks J DM S Over compensated Perfectly compensated Under compensated Figure 0 8 Probe Compensation 3 Use a nonmetallic driver to adjust the low frequency compensation adjustment hole on the probe until the waveform displayed is as the Perfectly compensated in the figure abov
23. 10 arbitrary waveforms LocalArb arb if the current position exist a file the original file will be overwriten You can output the arbitrary waveforms saved in the internal or external memory and for the specified operation please refer to the instruction of To Select Waveform 12 16 DS1000Z User s Guide Chapter 12 Signal Source RIGOL To Edit Waveforms Users can edit the waveforms which have been already saved Press Edit to enter the waveform editing interface 1 2 4 Interpolation Press Interp to turn the interpolation between the defined waveform points on or off ON the waveform editor will connect the two points with a straight line OFF the waveform editor will hold a constant voltage level between two points and create a step waveform Zoom Press Zoom to turn the zoom function on or off ON only displays the current point in the middle of the waveform editor window OFF displays all the initial points in the waveform editor window Current point Press CurPoint and use to set the desired points currently edited and the range available is from 1 to the initial points Method one Rotate 42 directly to set the desired points currently edited Method two Press to input desired paramrter values and unist directly using the pop up numeric keyboard Voltage Press Voltage to set the voltage value of the current point and the range available is from 2 5 V to 42 5 V Method one R
24. 14 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL Base 10 Logarithm Calculate the base 10 logarithm of specified signal source point by point and display the results Press MATH gt Math gt Operator to select Ig Press Display to turn on or off the base 10 logarithm operation function Press Source to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use 2 to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITI ON and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results Natural Logarithm Calculate the natural logarithm of specified signal source point by point and display the results Press gt Math gt
25. D HUE UPS PRA EI MUME 5 32 R5232 Trigger OPON 226i ossakide ute didtb ssa irMdbs ME YU raniona aa FRI xa PIECE 5 34 pow OPOE Tc TRAN 5 36 SPI Tigger COO E eios otet ipa oda d Hber ienee ENDARA EGANen 5 39 Trigger Output CONMECION uua eod DEDE DU RA DHRFORRRI RAE RE DI PUER Kr 5 41 Chapter 6 6 To Make Measurements cernere 6 1 Math Operaio oiioois bi Hea d oar Probe e ERRARE BU SEE PIS POE RETE PIS DOE ctce e Lach 6 2 PINE T T UU NT 6 2 SUDAN SOON NR DU 6 3 PI UIDIBN CON EE TT 1 7 nina 1 7 5L S 6 3 DIU s ren PUEDE PEE HN 6 4 a TT 6 6 AND S IST E TE I oT ULM 6 9 ELEC LONE TT 6 10 TOR CONST ACN oos eem a vao ur eax erties Sows are 6 11 NOT TOP Sr ais ates HE VER AMETE ia FEL A 6 12 ous se ps ih eee rere T renee 2 ET UTI TT 6 13 DAIS T o 0 0L S I 6 13 Savaro Code PP 6 14 Base 10 L ggl lilii se reckekxer b eua t IPEE EAA 6 15 Hanra BEST NM RT ELO TE 6 15 EDO Blocco tox Rcx ob Up DU DU ME DIR Ja RP dor RR dua 6 16 Fic ix do n 6 17 Lupe PT 6 18 Quick Measurement after UTD uus esci KeAE PE 2MELE PX IPIE t0 PEME E PA UMEA 6 18 XVIII DS1000Z User s Guide One key Measurement of 24 Parameters 6 19 Frequency Counter Measurement cccccceccseeeseeeraneeeeaneeeeanteneneeeeas 6 24 Pees SST SELLO sini mak cbe busca sec eGo en FUE da qd 6 25 TO Gear me Mie i TT T 6 26 Pll PCRS ETI TIL OL LU T 6 27 Atatisbi PEFIDEIDII osaceae UKI RRA RO NAR
26. NG AN Warning statements indicate the conditions or practices that could result in injury or loss of life N CAUTI ON Caution statements indicate the conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the Product DANGER indicates an injury or hazard may immediately happen WARNING indicates an injury or hazard may be accessible potentially CAUTION indicates a potential damage to the instrument or other property might occur Symbols on the Product These symbols may appear on the product A A A Hazardous Safety Protective Chassis Test Voltage Warnning Earth Ground Ground Terminal IV DS1000Z User s Guide RIGOL Measurement Category Measurement Category DS1000Z series digital oscilloscopes can make measurements in Measurement Category WARNI NG This oscilloscope can only be used for measurements within its specified measurement categories Measurement Category Definitions Measurement category is for measurements performed on circuits not directly connected to MAINS Examples are measurements on circuits not derived from MAINS and specially protected internal MAINS derived circuits In the latter case transient stresses are variable for that reason the transient withstand capability of the equipment is made known to the user Measurement category ll is for measurements performed on circuits directly c
27. RS232 you need to set the start bit data bits check bit optional and stop bit of each frame of data DS1000Z User s Guide 7 5 RIGOL Chapter 7 Protocol Decoding Data Bit yg PS iig peu 3g dois Start Bit represent when the data starts outputting Setting the Polarity is equivalent to specifying the Start Bit Data Bits represent the number of data bits actually contained in each frame of data Check Bit used to check the correctness of the data transmission Odd Checkout the number of 1 in the data bit and check bit is an odd For example when 0x55 01010101 is sent a 1 needs to be filled in the check bit to make the number of 1 be an odd Even Checkout the number of 1 in the data bit and check bit is an even For example when 0x55 01010101 is sent a 0 should be filled in the check bit None there would not be check bit during the transmission Press gt Decodel gt Decoder to select RS232 and open the RS232 decoding function menu 1 Press Decode to turn on or off the decoding function 2 TX and RX Channel Setting Press TX to select any channel CH1 CH4 as the transmitting channel and when OFF is selected no transmitting channel is set Use the same method the set the RX channel 3 Polarity Setting Press Polarity to select HII or BEBE and the default is normal The oscilloscope will select the rising or falling edge as the start position during
28. and read data DS1000Z User s Guide 15 7 RIGOL F DS1104Z ICPIP 172 16 3 16 INSTR 2013 4 10 11 30 44 177 Chapter 15 Remote Control 6 Load LXI webpage As this oscilloscope conforms to LXI C standards you can load LXI webpage through Ultra Sigma right click the resource name and select LXI Web or directly input the IP address in the browser Various important information about the oscilloscope including the model number manufacturer serial number description MAC address and IP address will be displayed on the webpage as shown in the figure below RIGOL Beyond Measure RIGOL Web Enable DS1000Z Series Welcome Page INN Network 520 Status Network Settings Help Security LXI Welcome to Web of DS1000Z Series Instrument Model Manufacturer Serial Number Description LXI Class LXI Version Host Name MAC Address IP Address Firmware Revision VISA TCP IP String Auto MDIX Capable VISA USB Connect String DS1104z RIGOL TECHNOLOGIES DS1T00000005 rigollan c 13 rigollan local 00 2A A0 AA E0 50 172 16 3 16 0 1 1 0 TCPIP 172 16 3 16 INSTR NO USBO0 0x40B1 0x1ACE DS1T00000008 INSTR Web Identification Indicator 2013 RIGOL Technologies Inc All Rights Reserved 15 8 DS1000Z User s Guide Chapter 16 Troubleshooting RIGOL Chapter 16 Troubleshooting The commonly encountered failures and their solutions are listed below When you encounte
29. be saved inside the instrument Press Export to enter the file store interface Please refer to the relative descriptions in 13 Store and Recall to save the reference waveform to internal or external memory To Import from Internal or External Memory Users can also import the reference waveform stored in the internal Flash memory or external USB storage device to the internal memory Press Import to enter the file recall interface Please refer to the relative descriptions in 13 Store and Recall to import the reference waveform to the internal memory of the instrument 8 4 DS1000Z User s Guide Chapter 9 Pass Fail Test RIGOL Chapter 9 Pass Fail Test Monitor the change of the signal by judging whether the input signal is within the mask created The test results can be displayed on the screen as well as be declared through the system sound or the pulse signal output from the Trigger Out connector at the rear panel The contents of this chapter To Enable Pass Fail Test To Select Source Mask Range Test and Ouput To Save the Test Mask To Load the Test Mask DS1000Z User s Guide 9 1 RIGOL Chapter 9 Pass Fail Test To Enable Pass Fail Test Press Utility gt Pass Fail gt Enable to select ON Note that when the time base is in XY mode the Pass Fail test function can not be enabled To start testing press Enable and select ON Then press Operate to select gt to start testing and select
30. by pressing Delete Use 42 to select and then press down 2 to return to the previous directory 5 Press OK to execute the saving operation 2 Loadthe specified type of file in the external USB storage device 1 Press Storage to select Traces and then press Load and use 42 to select Disk D and then press down 42 to open the local disk 2 If the USB storage device has saved files in this type use to select the desired file to load and press Load to load the file selected 13 6 DS1000Z User s Guide Chapter 13 Store and Recall RIGOL Disk Management Press Storage 2 DiskManage to turn on the disk management interface as shown in the figure below and use amp 2 to select the desired disk The disk currently selected is displayed in blue shading and press down 2 to open the disk selected Name Local Disk e Disk D Execute the following operations through the disk management menu To Select File Type To Create a New File or Folder To Delete a File or Folder To Rename a File or Folder To Clear the Local Memory DS1000Z User s Guide 13 7 RIGOL Chapter 13 Store and Recall To Select File Type Except the file types in Storage the oscilloscope can also display save or read some files for advanced applications such as mask file of the Pass Fail test pf waveform record file rec upgrade file rgl parameter file txt and reference waveform file ref Press Storage 2 Di
31. channel label at the bottom of the screen You can also press BW Limit continuously to switch between on and off of the bandwidth limit DS1000Z User s Guide 2 3 RIGOL Probe Ratio Chapter 2 To Set the Vertical System You can set the probe attenuation ratio manually The probe ratio values available are as shown in the table below Table 0 1 Probe Attenuation Coefficient Menu Attenuation coefficient 0 01X 1 100 0 02X 1 50 0 05X 1 20 0 1X 1 10 0 2X 1 5 0 5X 1 2 1X 1 1 2X 2 1 5X 5 1 10X 10 1 20X 20 1 50X 50 1 100X 100 1 200X 200 1 500X 500 1 1000X 1000 1 2 4 DS1000Z User s Guide Chapter 2 To Set the Vertical System RIGOL Waveform I nvert When waveform invert is enabled the waveform display rotates 180 degree relative to the ground potential When waveform invert is disabled the waveform display is normal Press CH1 gt Invert to enable or disable waveform invert Vertical Scale The vertical scale can be adjusted in Coarse or Fine mode Press CH1 gt Volts Div to select the desired mode Rotate VERTICAL SCALE to adjust the vertical scale clockwise to reduce the scale and counterclockwise to increase The scale information such as 1 A in the channel label at the bottom of the screen will change accordingly during the adjustment The adjustable range of the vertical scale is related to the probe ratio currently set By default the probe ratio is 1X and th
32. decided by the Memory Depth currently selected Please refer to the instruction in Memory Depth to select the desired memory depth Beep Ea you can not hear the sound of the beeper when the waveform recording is over KB you can hear the sound of the beeper when the waveform recording is over DS1000Z User s Guide 10 3 Chapter 11 Display Control RIGOL Chapter 11 Display Control You can set the type persistence time and brightness of waveform display as well as the grid type grid brightness of the screen display and the menu display time The contents of this chapter To Select the Display Type To Set the Persistence Time To Set the Waveform Intensity To Set the Screen Grid To Set the Grid Brightness To Set the Menu Display DS1000Z User s Guide 11 1 RIGOL Chapter 11 Display Control To Select the Display Type Press Display gt Type to set the waveform display mode to Vectors or Dots Vectors the sample points are connected by lines and displayed Normally this mode can provide the most vivid waveform to view the steep edge of the waveform such as square waveform Dots display the sample points directly You can directly view each sample point and use the cursor to measure the X and Y values of the sample point DS1000Z User s Guide Chapter 11 Display Control RIGOL To Set the Persistence Time Press Display gt Persis Time to set the persistence time of the oscill
33. decoding 4 Baud Rate Setting Press Baud use 2 to select the desired baud rate and you also can press Preset to select 2400 4800 9600 57600 115200 230400 460800 921600 and 1000000 and the default is 9600 the unit is bps 5 Endian Setting 7 6 DS1000Z User s Guide Chapter 7 Protocol Decoding RIGOL Press Endian to select LSB or MSB and the default is LSB 6 Data Packet Setting As mentioned before in RS232 you need to set the start bit data bits check bit optional and stop bit of each frame of data Start Bit is specified by the Polarity Setting The setting methods of other parameters are as follows Press Data to set the data width of each frame It can be set to 5 6 7 8 or 9 and the default is 8 Press Stop to set the stop bit after each frame of data It can be set to 1 bit 1 5 bits or 2 bits Press Parity to set the even odd check mode of the data transmission It can be set to None Odd or Even 7 Analog Channel Threshold Setting To judge logic 1 and logic 0 of the buses you need to set a threshold for each analog channel CH1 CH4 When the signal amplitude is greater than the preset value it is considered as 1 otherwise 0 i Threshold Level Press gt Decode Options gt Auto Thre to turn the auto threshold on or off When the auto threshold is turned on the instrument will calculate the center point according to the curr
34. determine check error according to the preset parameters Data trigger on the last bit of the preset data bits and even odd check bits When this trigger condition is selected 5 34 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL press Data Bits to select 5 bits 6 bits 7 bits or 8 bits press Data and input the data value according to the setting in Data Bits and the upper limits are 31 63 127 and 255 respectively Baud Rate Set the baud rate of data transmmision equal to specifying a clock frequency Press Baud to set the desired baud rate to 2400 default 4800 9600 19200 38400 57600 115200 and user defined the default unit is bps When User is selected press Setup and use amp 2 to set a more specific value from 1 to 900000 with an adjustment step of 1 bps Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameter noise rejection under this trigger type Trigger Level Use TRIGGER LEVEL to modify the level For details please refer to the description of Trigger Level on page 5 9 DS1000Z User s Guide 5 35 RIGOL Chapter 5 To Trigger the Oscilloscope 12C Trigger Option Trigger on the start condition restart stop missing acknowledgement or on the read write frame
35. displayed if the stop bit is less than 1 UIT 101115 101102 10010 The stop bit is less then 1 Check Error When check bit error is detected during the decoding error mark will be displayed For example when the transmitting terminal is set to none check and the decoder is set to odd check the following check error occurs 10111 LSB X BIN L SB 5 10111 10110 10010 The check bit detected is 0 Wherein there are odd number 1 of 1 in the 5 bit data 10111 and the check bit should be 1 but the check bit detected on the TX is 0 thus check error occurs Note that two error marks will be displayed when end frame error and check error are detected at the same time DS1000Z User s Guide 7 9 RIGOL Chapter 7 Protocol Decoding X BIN IMSBI 8 11101000 gt 01101010 b gt End frame error Check frame error 7 10 DS1000Z User s Guide Chapter 7 Protocol Decoding RIGOL 12C Decoding Option 12C serial bus consists of the clock line SCLK and the data line SDA SCLK A2 Device AO Host SCLK SDA SCLK sample the SDA on the clock rising edge or falling edge SDA denote the data channel Press gt Decodel gt Decoder to select 12C and open the 12C decoding funct
36. horizontal position and scale of the operation results Differentiate Calculate the derivative of the specified signal source For example you can use differentiate to calculate the instantaneous slope of a waveform Press MATH gt Math gt Operator to select diff Press Display to turn on or off the derivative operation function Press Source to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results DS1000Z User s Guide 6 13 RIGOL Chapter 6 To Make Measurements Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Diff Bias to set the derivative bias of the operation results and the range available is 1 to 50 Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITION and HORIZONTAL SCALE can a
37. horizontally expanded waveform Note compared to the main time base the delayed time base has increased the waveform resolution as shown in the figure above The delayed time base should be less than or equal to the main time base Tip You can also press down HORI ZONTAL SCALE delayed sweep shortcut key to directly switch to delayed sweep mode DS1000Z User s Guide 3 3 RIGOL Chapter 3 To Set the Horizontal System Time Base Mode Press IMENU in the horizontal control area HORIZONTAL at the front panel and then press Time Base to select the time base mode of the oscilloscope and the default is YT YT Mode This mode is the main time base mode and is applicable to two input channels In this mode the Y axis represents voltage and the X axis represents time Note that only when this mode is enabled can Delayed Sweep be turned on 3 4 DS1000Z User s Guide Chapter 3 To Set the Horizontal System RIGOL XY Mode In this mode the oscilloscope changes the two channels from voltage time display mode to voltage voltage display mode The phase deviation between two signals with the same frequency can be easily measured via Lissajous method The figure below shows the measurement schematic diagram of the phase deviation The signal must be centered horizontally According to sino A B or C D wherein 0 is the phase deviation angle between the two channels and the definiti
38. in delay trigger and the range is from 16 ns to 10 s Press Lower Limit to set the lower limit of the delay time in delay trigger and the range is from 8 ns to 9 99 s Note that the time lower limit must be lower than the time upper limit e gt lt trigger when the time difference AT between the specified edges of source A and source B is lower than the lower limit of the preset time or greater than the upper limit of the preset time Press Upper Limit to set the upper limit of the delay time in delay trigger and the range is from 16 ns to 10 s Press Lower Limit to set the lower limit of the delay time in delay trigger and the range is from 8 ns to 9 99 s Note that the time lower limit must be lower than the time upper limit Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameters trigger holdoff and noise rejection under this trigger type Trigger Level Use TRIGGER LEVEL to modify the level For details please refer to the description of Trigger Level on page 5 9 DS1000Z User s Guide 5 31 RIGOL Chapter 5 To Trigger the Oscilloscope Nth Edge Trigger Option Trigger on the nth edge that appears after the specified idle time as shown in the figure below Edge Type 4 Edge Num 2 P1 P2 M lt a P3 al lt _ gt
39. is 1 or the low level is 1 8 Width Setting Press Width to set the bit width of each frame The range available is from 8 to 32 9 Endian Setting Press Endian to select LSB or MSB and the default is MSB 10 Display related Setting Press Format to set the display format of the bus to Hex Decimal Binary ASCII or LINE Note that LINE format is displayed the acyual value of the bus in a binary number form and the order is consistent with the bus transmission sequence This format is only valid for the serial bus because the serial bus has the difference of bit sequence of LSB and MSB if bit sequence of the bus is selected MSB the LINE format is the same to the binary format Press Pos and use to adjust the vertical display position of the bus 11 Decoding Configuration Press Decoding1 Configure to turn the decoding configuration submenu on Press Label to turn the label display function on or off When it is turned on the bus label will be displayed at the upper left of the bus when the bus display is turned on 7 16 DS1000Z User s Guide Chapter 7 Protocol Decoding RIGOL Press Line to turn the bus display function on or off When it is turned on the bus display will be displayed on the screen and you can use Pos to adjust the vertical display position of the bus Press Format to turn the format display function on or off When it is turned on the current format display of the bus will be displayed on th
40. mask file to the internal or external memory To Load the Test Mask Users can also load the test mask files pf stored in the internal Flash memory or external USB storage device to the internal memory Press Load to enter the file recall interface Please refer to the relative descriptions in 13 Store and Recall to load the test masks to the internal memory of the instrument 9 4 DS1000Z User s Guide Chapter 10 Waveform Record RIGOL Chapter 10 Waveform Record Waveform record can record the waveforms of the input channels CH1 CH4 Waveform playback and analysis can provide better waveform analysis effect Note the horizontal time base must be set to YT mode during waveform record Press Utility gt Record gt Record to turn the waveform record on or off 1 Waveform Record Press Record to start the waveform record the current record information at the upper right corner e g a would change accordingly during the waveform record process and e will change into m automatically in the menu At this point press Record again to stop the waveform record You can set the parameter of the waveform record according to the instruction of Playback Setting before waveform record 2 Playback Press Play to play the waveform recorded For specified setting of playing please refer to the instruction of Record Setting 3 Stop You can press Stop to stop the playback during the waveform playback proc
41. measurement results at the bottom of the screen Multi period measure the Period and Frequency of the current signal within multiple periods and display the measurement results at the bottom of the screen Rise Time measure the Rise Time of the current signal and display the measurement result at the bottom of the screen Fall Time measure the Fall Time of the current signal and display the measurement result at the bottom of the screen Note the AUTO function requires that the frequency of the signal under test should be no lower than 50 Hz the duty cycle be greater than 196 and the amplitude be at least 20 mVpp If the parameters of the signal under test exceed these limits after this softkey is pressed the quick parameter measurement items might not be displayed in the pop up menu 6 18 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL One key Measurement of 24 Parameters Press corresponding softkey under the IMENU at the left of the screen to quickly measure the 24 parameters and realize One key measurement The measurement result will be displayed at the bottom of the screen The icons of time and voltage parameters in the measurement items and the measurement results on the screen are always marked in the same color with the channel Measure gt Source currently used But the delay and phase measurement items are always marked in green For example Note if the measuremen
42. memory depth automatically according to the current sample rate When two channels are enabled the memory depths available include Auto 6kPoints 60kPoints 600kPoints 6MPoints In Auto mode the oscilloscope selects the memory depth automatically according to the current sample rate DS1000Z User s Guide 4 7 RIGOL Chapter 4 To Set the Sample System When four channels are enabled the memory depths available include Auto 3kPoints 30kPoints 300kPoints 3MPoints In Auto mode the oscilloscope selects the memory depth automatically according to the current sample rate 4 8 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Chapter 5 To Trigger the Oscilloscope For trigger you set certain trigger condition according to the requirement and when a waveform in the waveform stream meets this condition the oscilloscope captures this waveform as well as the neighbouring part and displays them on the screen For digital oscilloscope it displays waveform continuously no matter whether it is stably triggered but only stable trigger can ensure stable display The trigger circuit ensures that every time base sweep or acquisition starts from the input signal and the user defined trigger condition namely every sweep is synchronous to the acquisition and the waveforms acquired overlap to display stable waveform Trigger setting should be based on the features of the input signal thus you need to have some knowledg
43. memory has saved files in this type use 2 to select the desired file to load and press Load to load the file selected DS1000Z User s Guide 13 5 RIGOL Chapter 13 Store and Recall External Storage and Recall Before using external storage and recall make sure that the USB storage device is connected correctly External storage supports all the types of files in Storage but in recall Picture CSV and Param are not supported 1 Save the specified type of file in the external USB storage device 1 Connect the signal to the oscilloscope and obtain stable display 2 Press gt Storage to select Traces press Save and use 4 to select Disk D and press down amp 2 to open the USB storage device 3 Use to select the desired storage position The file can be stored under the root directory or in a certain folder under the root directory of the USB storage device Note press NewFolder to create a new folder and for specific operation please refer to the instruction of To Create a New File or Folder 4 After the storage position is selected press New File to create a new file name using the pop up keyboard for detail operations please refer to the instruction of To Create a New File or Folder If the internal memory has saved files in this type use to select the file and Save and Delete are illuminated at this point press Save to execute the saving operation the original file can be overwritten or be delected
44. nt Depto E LIS UA da ERE 10 2 Record SEDE urone EAE FERE AXI MU RAM ERU MdL KR DU NOD ER URL Rb edd 10 3 Chapter 11 11 Display Control ina aiv o aad d odo dae 11 1 DS1000Z User s Guide XIX RIGOL To eB e Display TIDE Goa iicatacevaia di diese eia 11 2 To Set the Persistence TIBIBu ue caa xrieibr eee DRR EC HRR epe Gba dU M d p E E HRS 11 3 To Set the Waveform Intensity essssssseee mens 11 5 To Set the SEDENT Groeien biriken keki MADRE KE ERE eeu 11 5 To Set the Grid Brightness eiin TT 11 5 Tn Set th Menu DISIBY iuostiscivecoicix adi dev FA RI NEN rS REPE RE d DLE REM UR 11 5 Chapter 12 each Ec 12 1 To Output Basic WAV STON S eciiisetexa onire Ebr eap e act dr EROR ER t Ed 12 2 To Output Sine TEaVEFORD bad a rae PUER n REPERI MR REL AMORE ERR EIE RRBEE 12 2 To Output Square WiVelprTit ua cecinere extr epos Done dedo sia e nega 12 4 Te Output Ramp VRUOIDIIR LG cae epuild qe bi a pha dive wir popchrtue sed mE 12 4 To D tout Pulse VEOauaIEBPTIE ics codvnxs koi ptt eben Oe en db tcn ed 12 5 To Output DC Wau GIGI siepe Sepa HE ROERIR ened eae 12 5 To Output Noise W avefortn ecce rx coe ace x ek kk REX Re 12 6 To Output Bullb I n VWiavefpl tiui e err rior n OE kh E C e aa 12 7 To Output Arbitrary VIGVBEIETEL assises Beb oda RI ERR BR PEERS o dE F PIE G EO 12 12 To Select Wav OI II D T TTE 12 14 To Create 0r D Eo E T 12 14 To Edit WavelormJs ac penc reri brin rer AFER ad D kar EET EHE E eer 12 17 c
45. order is consistent with the bus transmission sequence This format is only valid for the serial bus because the serial bus has the difference of bit sequence of LSB and MSB if bit sequence of the bus is selected MSB the LINE format is the same to the binary format DS1000Z User s Guide 7 3 RIGOL Chapter 7 Protocol Decoding Press Pos and use to adjust the vertical display position of the bus 6 Decoding Configuration Press Decoding1 Configure to turn the decoding configuration submenu on Press Label to turn the label display function on or off When it is turned on the bus label will be displayed at the upper left of the bus when the bus display is turned on Press Line to turn the bus display function on or off When it is turned on the bus display will be displayed on the screen when the bus display is turned on and you can use Posto adjust the vertical display position of the bus Press Format to turn the format display function on or off When it is turned on the current format display of the bus will be displayed on the right of the label display when the bus display is turned on and you can use format to set the display format of the bus Press Width to turn the width display function on or off When it s turned on the current bus width will be displayed on the right of the format display when the bus display is turned on and you can use Width softkey to set the bus width Press DataSrc to select Trace
46. set the desired points currently edited and the range available is from 1 to the initial points Method one Rotate amp 2 directly to set the desired points currently edited Method two Press to input desired paramrter values and unist directly using the pop up numeric keyboard Voltage Press Voltage to set the voltage value of the current point and the range available is from 2 5 V to 2 5 V DS1000Z User s Guide 12 15 RIGOL Chapter 12 Signal Source Method one Rotate 2 directly to set the desired voltage value Method two Press 42 to input desired paramrter values and unist directly using the pop up numeric keyboard 6 Time Press Time to set the duration time of the current point and this setting is limited by the duration times of the previous point and the next point The point 1 is fixed at 0 s 7 Insert Press Insert to insert a new point at the middle position of the current edited point and the next edited point 8 Delete Press Delete to delete the current point from waveform and connect the remaining points using the currtnt interpolation method Note that point 1 can not be deleted 9 Apply Press Apply to apply the waveform currently edited 10 Save Press Save to enter the files store interface Please refer to the instruction of 13 Store and Recall to save the waveform files currently created in the internal or external memory in arb format The internal memory of the instrument can store
47. set the symmetry of the current ramp and the range available is from 0 to 100 12 4 DS1000Z User s Guide Chapter 12 Signal Source RIGOL To Output Pulse Waveform Press Src1 Setup to enter the waveform setting interface Press Wave to select Pulse at this point you can set relative parameter of the sine signal For the specified setting method please refer to the instruction of To Output Sine Waveform Duty cycle is introduced only in this chapter Duty cycle Duty cycle is difined as the percentage that the high level takes up in the whole period of pulse t k Duty Cycle t T 100 pua To set the duty cycle Press Duty Cycle and use 2 to set the duty cycle of the current pulse signal and the range available is from 1096 to 9096 To Output DC Waveform Press Srcl Setup to enter the waveform setting interface Press Wave to select DC at this point you can output DC signals with 2 5 V to 2 5 V offset 1 Output Press Output to turn the signal output on or off 2 To set DC offset Press Offset to set the offset value of the current DC signal and the range available is 2 5 V to 42 5 V For the setting method please refer to the instruction of To set the DC offset voltage DS1000Z User s Guide 12 5 RIGOL Chapter 12 Signal Source To Output Noise Waveform Press Srcl Setup to enter the waveform setting interface Press Wave to select Noise at this point you can output noise signa
48. switch the acquisition mode Normal In this mode the oscilloscope samples the signal at equal time interval to rebuild the waveform For most of the waveforms the best display effect can be obtained using this mode Average In this mode the oscilloscope averages the waveforms from multiple samples to reduce the random noise of the input signal and improve the vertical resolution The greater the number of averages is the lower the noise will be and the higher the vertical resolution will be but the slower the response of the displayed waveform to the waveform changes will be The available range of the number of averages is from 2 to 8192 and the default is 2 When Average mode is selected press Averages and use 2 to set the desired number of averages as the power function of 2 The Waveform before Average 4 2 DS1000Z User s Guide Chapter 4 To Set the Sample System The Waveform after 256 Averages RIGOL DS1000Z User s Guide 4 3 RIGOL Chapter 4 To Set the Sample System Peak Detect In this mode the oscilloscope acquires the maximum and minimum values of the signal within the sample interval to get the envelope of the signal or the narrow pulse of the signal that might be lost In this mode signal confusion can be prevented but the noise displayed would be larger In this mode the oscilloscope can display all the pulses with pulse widths at least as wide as the sample period High Resol
49. the capacity of the USB disk being used with this oscilloscope is no larger than 8 GBytes 4 Restart the instrument and then insert the USB disk to check it 5 If the USB disk still can not be used normally please contact RIGOL 16 2 DS1000Z User s Guide Chapter 17 Specifications RIGOL Chapter 17 Specifications All the specifications are guaranteed except parameters marked with Typical and the oscilloscope needs to operate for more than 30 minutes under the specified operation temperature Sample Sample Mode Real time Sample Rate Real time sample 1 GSa s single channel 500 MSa s dual channel 250 MSa s four channel Averaging After both the channels finish N samples at the same time N can be 2 4 8 16 32 64 128 256 512 1024 High Resolution The highest resolution is 12 bit Peak Detection 4ns Memory Depth Input Number of Channels Input Coupling Single channel Auto 12k pts 120k pts 1 2M pts 12M pts and 24M pts option are available Dual channel Auto 6k pts 60k pts 600k pts 6M pts and 12M pts option are available Four channel Auto 3k pts 30k pts 300k pts 3M pts and 6M pts option are available four channel DC AC or GND Input Impedance 1 MQ 2 13 pF 3 pF Probe Attenuation Coefficient 0 01X 1000X 1 2 5 step Max Input Voltage 1MQ Maximum input voltage of the analog channel CAT 300 Vrms CAT I
50. to DS1104Z S and DS1074Z S 18 Source2 Waveform Display the type of waveform currently set for Sourcel e When the modulation is enabled will be displayed at the bottom of the Source2 Waveform When the impedance of signal source is set to 50 Q W will be displayed at the bottom of the Source2 Waveform Only available to DS1104Z S and DS1074Z S 19 Notification Area Display system time sound icon and USB disk icon Sound Icon when sound is enabled E will be displayed Press Utility gt Sound to enable or disable the sound e USB Disk Icon when a USB disk is detected will be displayed 20 Operation MENU Press any softkey to activate the corresponding menu The following symbols might be displayed in the menu B Denote that O at the front panel can be used to select parameter items The backlight of D turns on when parameter selection is valid DS1000Z User s Guide 1 21 RIGOL Chapter 1 Quick Start Denote that you can use O to adjust the parameter and then press down to select the parameter Denote that press D to input desired paramrter values directly using the pop up numeric keyboard The backlight of t turns on when parameter input is valid Denote that the current menu has several options Denote that the current menu has a lower level menu Press this key to return to the previous menu The number of the dots denotes that the number of the pages the current menu has 1 22 DS1000
51. with specific device address and data value In 12C trigger you need to specify the SCL and SDA data sources The figure below shows the complete data transmission of 12C bus p ia l 1 l j l j j l l j l l j l l l l j M 71 l l l l j j l I i I I l l I I l l 1 I l l I j i I I I l l I I l l 1 I I I S IP l od START MESS WT ux DATA aoa ACK STOP condition condition Trigger Type Press Type to select I 2C At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press SCL and SDA to specify the data sources of SCL and SDA respectively They can be set to CH1 CH4 and the current trigger source is displayed at the upper right corner of the screen Trigger Condition Press When to select the desired trigger condition Start trigger when SDA data transitions from high to low while SCL is high Restart trigger when another start condition occurs before a stop condition Stop trigger when SDA data transitions from low to high while SCL is high Missing ACK trigger when the SDA data is high during any acknowledgement of SCL clock position Address trigger on the clock SCL edge corresponding to the byte of data SDA 5 36 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL behind the preset address Write Re
52. 000A series oscilloscope supports AM and FM modulations The modulated waveform consists of carrier waveform and modulating waveform The carrier waveform can be the signal outputted from the signal source and the modulating waveform can be sine square ramp and noise signal which builted in the signal source Press Modulation to turn the modulation function on or off 1 To select the modulation type Press Mod Type set the modulation type of the current signal Amplitude modulation the amplitude of the carrier waveform varies with the amplitude of the modulating waveform Qc Modulating waveform Carrier waveform Modulated waveform After AM is selected you can set the frequence of the modulating waveform and the AM modulation depth Frequencey press Frequency to set the frequence of the modulating waveform and the range available is from 1 Hz to 50 kHz For the setting method please refer to the instruction of the To set frequency Modulation depth modulation depth is expressed as a percentage that DS1000Z User s Guide 12 19 RIGOL Chapter 12 Signal Source denotes the amplitude veriation degree Press Depth to set AM modulation depth and the range available id from 0 to 120 In 0 modulation the output amplitude is half of the carrier waveform amplitude in 10096 modulation the output amplitude is equal to the carrier waveform amplitude when the modulation is larger than 10096 the envelope
53. 1 Chapter 14 System Function Setting RIGOL Chapter 14 System Function Setting The contents of this chapter B Remote Interface Configuration B System related DS1000Z User s Guide 14 1 RIGOL Chapter 14 System Function Setting Remote I nterface Configuration DS1000Z can communicate with PC via LAN and USB buses Please refer to the introduction below to configure the corresponding interface before using the remote interfaces LAN Setting Press gt 10 Setting gt LAN Conf to turn on the LAN setting interface You can view the network connection status and configure the network parameters Lan Setting Network Status Current IP Config Type WAC Address D0 11 2 MAC Address VISA Address TCPIPO 172 16 3 115 INSTR VISA Address DHCP yes Auto IP IP Config Type uto Status Static IP Network Status Connect the oscilloscope to your local area network using the network cable The network hole of the oscilloscope is at the rear panel The oscilloscope will give different prompts according to the current network connection status Net Config Success Acquire IP IP Conflict Unconnected DHCP Fail Read Status Fail 14 2 DS1000Z User s Guide Chapter 14 System Function Setting RIGOL IP Configuration Type DHCP The configuration type of the IP address can be DHCP auto IP or static IP In different IP configuration type the configuration mode of the network parameters such as the I
54. 1 Setup submenu Press Src1 Setup to select the signal type currently output and set the relative parameters of the signal Press StatusDisp to view the current signal status of SOURCE1 and SOURCE2 for example frequency amplitude offset phase modulation type and modulation frequency The contents of this chapter B To Output Basic Waveform B To Output Built In Waveform WB To Output Arbitrary Waveform DS1000Z User s Guide 12 1 RIGOL Chapter 12 Signal Source To Output Basic Waveform To Output Sine Waveform Press Src1 Setup to enter the waveform setting interface Press Wave to select Sine at this point you can set relative parameters of the sine signal 1 4 Output Press Output to turn the signal output on or off To set frequency Press Frequency to set the frequency of the current signal and the range available is from 100 mHz to 25 MHz Note that different waveform has different frequency the frequency ranges of square and pulse are 100 mHz to 15 MHz the frequency range of ramp is 100 mHz to 100 kHz Method one Rotate 4 directly to set the desired frequency value Method two Press to input desired paramrter values and unist directly using the pop up numeric keyboard To set amplitude Press Amplitude to set the amplitude of the current signal and the range available is from 20 mVpp to 5 Vpp if the impedance is HighZ or from 10 mVpp to 2 5 Vpp if the impedance is 50 Q Method o
55. 5 Video Polarity oh eed 15 Threshold quatre idend 25 Video Standard ss 15 T ime Setting voa e Rea s 12 Video Trigger ccn 15 TimeOut Trigger sssse 23 MESA sss ere teenies 5 Traces scr rrr m petas 3 VMAX OPE 22 Track Mode ccce 33 VITIHD 3 ea Se o SERRE ERR cave 22 Huic E ince 8 VDD saeocnt e aa a 22 Trigger Coupling ox errem 5 MEIISi resist on tue rr E ERR ER ERR 22 Trigger Holdoff eec ez 6 MOD cists vis tek rni eh o rae d 22 Trigger Level 9 Waveform Confusion 5 Trigger MOGs ucc esten ves 3 Waveform Distortion 5 Trigger Source ssesessss 2 Waveform Invert accer 5 a M ingens 6 Waveform Leakage 6 NVa Mp eriou beide es 22 Waveforms scce 3 Vaga ice avere esee ed ai 22 Window Function sses 7 MbaSei ee Er ERR 22 AY ouis ee PP DE EA 5 VEE OTS deest ata 2 GE 4 2 DS1000Z User s Guide
56. Contents Guaranty and Declaration enses sees eese e enean annua nnn l Safety REQuireinenb cscccccessnesessnssescnssessnnssssenesesnsesasenacecanesannensasnesseanessnane lI General Sate SUMA Y einna ane ANTEE EER ET II Safety Terms ang SYMDO S iercrstriiretiiniir binenta EEPE NINKE R BA DAANEN IV Measurement CatEgOry senenin nien E EE SEEEN V ventilation Requirement is usce xebto nea vh n Rc gx Ea Rue a VI Working EIVIPODWERDE cs iier pec kr REA Ero OPER Xt e Ye ERU dete aes VII General Care and CIS OPER TT TP IX Environmental ConsiderabioriSuadu a d e ERE RE RF ER RE deca D M ERR PAREM EROR RAS X DS1000Z Series Overview eeeee sies sienne eren nnns XI Document OvervieW La essvacavitasine vin RR V KG acd d ac RR REOR GN E WU XIII Chapter 1 1 Quick Star biasicsisncissscastassanscnssnndssosassiecsaveanensnssnasnavasennncsina 1 1 General WTS S d ed EE PUEDE EXER Y HE Apa tani asia autre ers 1 2 Appearance dnd DIMENSIONS iouis cese Fa eH a b90P Pird lA UR Gara RR BEER Eo iaa 1 3 To Prepare the Oscilloscope for Use Lee oir eure OE DCR RE QUPE PREX EIFE AERE 1 4 To Adjust th Supporting Les aia cisiitescradvsdacrstnteotiantncbakieanvdnadanneatink 1 4 To Connect to Power Supply Liciuaizerbesici aeo E Fe ade FERCE BUE Sap EIER MM US 1 5 Poweron LHepecHOD uec cesiubadas Exon o bd d ER ED Do LEO B RA EL a 1 6 To Lonmear ue PIOBB aatia wl SEM t oie AU REL URS uir aia DRM ES ER REED 1 7 PUNCH ON spec ccrisno
57. Device and the default is Computer at this point the oscilloscope can communicate with the PC 14 6 DS1000Z User s Guide Chapter 14 System Function Setting RIGOL System related Sound When the sound is enabled you can hear the sound of the beeper when you press a function key or a menu softkey or when the prompt message pops up Press Utility gt Beeper to select on or x off The default is off When the sound is turned on a trumpet icon E will be displayed at the lower right corner of the screen Language This oscilloscope supports multiple language menus Chinese English help and prompt messages Press Utility gt Language and use 2 to select the desired language Then press down 2 to select the language DS1000Z User s Guide 14 7 RIGOL Chapter 14 System Function Setting System I nformation Press Utility gt System gt System Info to view the version information of your oscilloscope The system information contains the following contents as shown in the figure below tem Information Manufacturer Model 181104 SN 51T00000008 U tra Vision Software Version Power on Recall You can set the system configuration to be recalled when the oscilloscope is powered on again after power off Press System Power On Set to select Last default or Default Last return to the setting of the system at last power off Default return to the factory setting of the sys
58. I 100 Vrms transient overvoltage DS1000Z User s Guide RIGOL Chapter 17 Specifications 1000 Vpk With RP2200 10 1 probe CAT II 300 Vrms Horizontal Time Base Scale 5 ns div to 50 s div Time Base Accuracy lt 25 ppm Time Base Drift lt 5 ppm year Max Delay Range Pre trigger negative delay 21 2 screen width Post trigger positive delay 1 s to 5 000 s Time Base Mode Number of X Ys Waveform Capture Rate Vertical Bandwidth 3dB Y T X Y Roll Delayed 1 path 30 000 wfms s dots display DS1104Z DC to 100 MHz DS1074Z DC to 70 MHz Single Bandwidth DS1104Z DC to 100 MHz DS1074Z DC to 70 MHz Vertical Resolution Vertical Scale 8 bit 1 mV div to 10 V div Offset Range 1 mV div to 499 mV div 2 V 500 mV div to 10 V div 100 V Bandwidth Limit 20 MHz Low Frequency Response AC Coupling lt 5 Hz on BNC 3dB Rise Time DS1104Z 3 5 ns DS1074Z 5 ns DC Gain 10 mV 4 full scale 17 2 DS1000Z User s Guide Chapter 17 Specifications RIGOL Accuracy gt 10 mV 3 full scale DC Offset Accuracy 0 1 div 2 mV 1 offset Channel to Channel Isolation Trigger Trigger Level Range DC to maximum bandwidth gt 40 dB 5 div from the center of the screen Trigger Mode Auto Normal Single Holdoff Range 16 ns to 10 s High Frequency 75 kHz Rejection Low Freque
59. IGOL Pattern Trigger Identify a trigger condition by looking for a specified pattern This pattern is a logical AND combination of the two channels Each channel can have a value of high H low L or don t care X A rising or falling edge can be specified for one channel included in the pattern When an edge is specified the oscilloscope will trigger at the edge specified if the pattern set for the other channel is true H or L If no edge is specified the oscilloscope will trigger on the last edge that makes the pattern true If both the channels in the pattern are set to Don t Care the oscilloscope will not trigger Trigger Type Press Type to select Pattern At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Channel Selection Press Source to select CH1 CH4 as the channel source for H L X or edge condition The current signal source is displayed at the upper right corner of the screen Pattern Setting Press Code to set the pattern of the current channel At this point the pattern setting area as shown in the figure below is displayed at the bottom of the screen e a set the pattern of the channel selected to H namely the voltage level is higher than the threshold level of the channel e B set the pattern of the channel selected to L namely the voltage level is lower than the threshold level of the channel e El set the p
60. LEVEL to modify the level An orange trigger level line and the trigger mark El appear on the screen and move up and down with the rotation of the knob while at the same time the trigger level value such as at the lower left corner of the screen also changes accordingly When stopping turning the knob the trigger level line and the trigger mark disappear in about 2 s DS1000Z User s Guide 5 9 RIGOL Chapter 5 To Trigger the Oscilloscope Pulse Trigger Trigger on the positive or negative pulse with a specified width Trigger Type Press Type to select Pulse At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 as the Trigger Source The current trigger source is displayed at the upper right corner of the screen Note select channel with signal input as trigger source to obtain stable trigger Pulse Condition Press When to select the desired pulse condition e WEE trigger when the positive pulse width of the input signal is greater than the specified pulse width e EG trigger when the positive pulse width of the input signal is lower than the specified pulse width e KEEN trigger when the positive pulse width of the input signal is greater than the specified lower limit of pulse width and lower than the upper limit of pulse width e BXER trigger when the negative pulse width of the input s
61. Maximum Minimum Peak Peak Value Top Value Bottom Value Amplitude Average Mean Square Root Overshoot Pre shoot Area Period Area Frequency Period Rise Time Fall Time Positive Pulse Width Negative Pulse Width Positive Duty Cycle Negative Duty Cycle Delay A gt B Delay ASBt Phase ASB Phase ASBt Number of Display 5 measurements at the same time Measurements Measurement Screen Region Range Measurement Average Max Min Standard Deviation Number of Statistic Measurements Counter Hardware 6 bits counter channels are selectable DS1000Z User s Guide RIGOL Chapter 17 Specifications Math Waveform A B A B AxB A B FFT amp amp intg diff sqrt Ig In Operation exp abs FFT Window Rectangle Hanning Blackman Hamming Flat Top Triangle FFT Display Half Full FFT Vertical Scale dB dBm Vrms Number of Buses for Decoding 2 Decoding Type Display Display Type Display Resolution Display Color Parallel standard RS232 UART option 12C option SPI option 7 0 inches TFT LCD display 800 horizontalx RGBx480 vertical pixel 160 000 Color TBD Persistence Time Min 100 ms 200 ms 500 ms 15 2 s 5 s 10 s 20 s Infinite Display Type 1 0 Standard Ports Dots Vectors USB HOST USB DEVICE LAN Aux TrigOut PassFail Signal Sourse DS1000Z S Number of 2 Channels Sample Rate 200 MSa s Vertica
62. Operator to select In Press Display to turn on or off the natural logarithm operation function Press Source to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted DS1000Z User s Guide 6 15 RIGOL Chapter 6 To Make Measurements display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results Exponential Calculate the exponential of specified signal source point by point and display the results Press MATH Math gt Operator to select exp Press Display to turn on or off the exponential operation function Press Source to select the desired
63. Option Management to activate corresponding option The contents of this chapter Parallel Decoding RS232 Decoding Option 12C Decoding Option SPI_Decoding Option DS1000Z User s Guide 7 1 RIGOL Chapter 7 Protocol Decoding Parallel Decoding Parallel bus consists of clock line and data line As shown in the figure below CLK is the clock line while BitO and Bit1 are the 0 bit and 1st bit on the data line respectively BitO Bit1 The oscilloscope will sample the channel data on the rising edge falling edge or the rising amp falling edges of the clock and judge each data point logic 1 or logic 0 according to the preset threshold level Press gt Decodel gt Decoder to select Parallel and open the parallel decoding function menu 1 Press Decode to turn on or off the decoding function 2 ClockLine Setting CLK Press CLK to select any channel CH1 CH4 as the clock channel If OFF is selected no clock channel is set Press Edge to set the oscilloscope to sample the channel data on the rising edge EJ falling edge E2 or rising amp falling edges R if no clock channel is selected the instrument will sample when the channel data jumps in the decoding 3 Data Line Setting Set the bus bits Press Width to set the data width of the parallel bus namely the number of bits per frame The default is 1 and the maximum is 16
64. P address is different Press Configure and use to select DHCP Then press down 2 to select this type When DHPC type is valid the DHCP server in the current network will assign the network parameters such as the IP address for the oscilloscope pepj Ac E zEuMS IP Configuration Type Auto I P Press Config Mode and use 42 to select Auto IP Then press down 2 to select this type When the auto IP type is valid disable DHCP manually Gate and DNS are added to the right side of the screen and users can define the gateway and DNS server address of the oscilloscope In auto IP mode the oscilloscope will get the IP address ranging from 169 254 0 1 to 169 254 255 254 and the subnet mask 255 255 0 0 automatically according to the current network configuration IP Configuration Type Static I P Press Config Mode and use to select Static IP Then press down 42 to select this type When this type is valid disable DHCP and auto IP manually IP Address Mask Gate and DNS are added to the right of the screen At this point users can define their own network parameters such as the IP address of the oscilloscope 1 SetthelP Address The format of IP address is nnn nnn nnn nnn wherein the range of the first nnn is from 0 to 223 except 127 and the ranges of the other three nnn are DS1000Z User s Guide 14 3 RIGOL Chapter 14 System Function Setting from 0 to 255 You are recommended to ask your network administra
65. RIGOL User s Guide DS1000Z Series Digital Oscilloscope Aug 2013 RIGOL Technologies Inc RIGOL Guaranty and Declaration Copyright 2013 RIGOL Technologies Inc All Rights Reserved Trademark I nformation RIGOL is a registered trademark of RI GOL Technologies Inc Publication Number UGA17101 1112 Notices RIGOL products are protected by patent law in and outside of P R C RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at company s sole decision Information in this publication replaces all previously corresponding material RIGOL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information contained Any part of this document is forbidden to be copied or photocopied or rearranged without prior written approval of RIGOL Product Certification RIGOL guarantees this product conforms to the national and industrial standards in China as well as the 1509001 2008 standard and the 15014001 2004 standard Other international standard conformance certification is in progress Contact Us If you have any problem or requirement when using our products please contact RIGOL Technologies Inc or your local distributors or visit www rigol com DS1000Z User s Guide RIGOL Safety Requirement General Safety Summary Please review th
66. Reset Stat to clear the history data and make statistic again 6 28 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL Cursor Measurement Cursors are the horizontal and vertical marks that can be used to measure the X axis values usually Time and Y axis values usually Voltage on a selected waveform Please connect the signal to the oscilloscope and obtain stable display before using cursor measurement All the Auto Measurement parameters can be measured through cursor measurement Press gt Mode at the front panel and use amp 2 to select the desired cursor mode the default is OFF and then press down the knob The modes available are Manual Track and Auto DS1000Z User s Guide 6 29 RIGOL Chapter 6 To Make Measurements Manual Mode In this mode a pair of cursors will appear You can adjust the cursors manually to measure the X or Y X increment or Y increment between cursors and the reciprocal of X increment on the waveform of the selected source CH1 CH2 or MATH Press Couson gt Mode gt Manual to turn the manual cursor function on and the measurement results will be displayed at the upper left corner of the screen in the following mode 800 0us 1 600ms 625 0 Hz e The Xor Y value at cursor A AX or AY X value takes the trigger position as reference and Y value takes the channel GND as reference e TheXor Y value at cursor B BX or BY X v
67. Z User s Guide Chapter 1 Quick Start RIGOL To Use the Security Lock If needed you can use the security lock please buy it yourself to lock the oscilloscope to a fixed location The method is as follows align the lock with the lock hole and plug it into the lock hole vertically turn the key clockwise to lock the oscilloscope and then pull the key out ge eny Lock Hole Figure 0 12 To Use the Security Lock Note please do not insert other articles into the security lock hole to avoid damaging the instrument DS1000Z User s Guide 1 23 RIGOL Chapter 1 Quick Start To Use the Built in Help System The help system of this oscilloscope provides instructions for all the function keys including menu keys at the front panel Press to open the help interface and press again to close the interface The help interface mainly consists of two parts The left is Help Options and you can use Button or Index mode to select The right is Help Display Area Help Options Help Display Area Butte n Timeout To Ind x F1 Figure 0 13 Help Information Default mode In this mode you can press the button except the power key EJ the knob amp 2 and the menu page up down key at the front panel directly to get the corresponding help information in the Help Display Area Use 42 to select To Index and then press the knob to switch to Index mode I ndex In this mode use 44 to select t
68. a Sigma and the software will automatically search for the oscilloscope resources currently connected to the PC You can also click to search the resources During the search the status bar of the software is as shown in the figure below 15 4 DS1000Z User s Guide Chapter 15 Remote Control RIGOL 4 View the device resource The resources found will appear under the RIGOL Online Resource directory and the model number and USB interface information of the instrument will also be displayed as shown in the figure below LAN GPIB USB TMC RS232 IVI Config Verify All RIGOL Online Re xO4CE DS1TOOD00006 INSTR VSBTMC instrument 5 Communication test Right click the resource name DS1104Z USBO 0x1AB1 0x04CE DS1T0000000006 INSTR to select SCPI Panel Control to turn on the remote command control panel as shown in the figure below through which you can send commands and read data FlDS1104Z USBO 0x1AB1 0x04CE DS1100000006 INSTR 2013 4 26 15 27 42 447 DER N o USBO Ox1AB1 OxO4CE DS1TO0000006 INSTR urn RIGOL TECHNOLOGIES DS1104Z DS1T00000006 00 01 00 DS1000Z User s Guide 15 5 RIGOL Chapter 15 Remote Control Remote Control via LAN 1 Connect the device Connect the oscilloscope to your LAN using a network cable 2 Configure network parameters Configure the network parameters of the oscilloscope according to the description in LAN Sett
69. ad or R W direction After this trigger condition is selected press AddrBits to select 7 bits 8 bits or 10 bits press Address to set the address value according to the setting in AddrBits and the ranges are from 0x0 to Ox7F 0x0 to OxFF and 0x0 to Ox3FF respectively press Direction to select Read Write or R W note when AddrBits is set to 8 bits this setting is not available Data the trigger searches for the control byte value on the data line SDA following which there is a reading bit and an acknowledgement bit and then searches for the specified data value When this event occurs the oscilloscope will trigger on the clock edge of the acknowledgement bit behind the data byte After this trigger condition is selected press Byte Length to set the length of the data and the range is from 1 to 5 press CurrentBit to select the desired data bit and the range is from 0 to Byte Length x8 1 press Data to set the data pattern of the current data bit to X H or L press AllBits to set the data pattern of all the data bits to the data pattern specified in Data A amp D trigger when the Address and Data conditions are met at the same time After this trigger condition is selected press AddrBits to select 7 bits 8 bits or 10 bits press Address to set the address value according to the setting in AddrBits and the ranges are from 0x0 to Ox7F 0x0 to OxFF and 0x0 to Ox3FF respective
70. age and Recall External Storage and Recall Disk Management Factory DS1000Z User s Guide 13 1 RIGOL Chapter 13 Store and Recall Storage System Press Storage to enter the store and recall setting interface This oscilloscope provides a USB Host interface at the front panel to connect USB storage device for external storage and the internal memory capacity Local Disk is 90 5 MByte The USB storage device connected is marked as Disk D Name Local Disk Disk D 13 2 DS1000Z User s Guide Chapter 13 Store and Recall RIGOL Storage Type Press Storage gt Storage to select the desired storage type The default is Picture The storage and recall descriptions of each type are as follows 1 Picture Save the screen image in external memory in PNG BMP8 BMP24 J PEG or TIFF format You can specify the file name and saving directory and save the corresponding parameter file txt under the same directory using the same file name and the function of this parameter file is the same to the Parameters The recall of image and parameter files is not supported After seleting this type Press Pic Type to select the desired storage format Press Para Save to enable or disable the parameter save function One key Bitmap Saving After a USB storage device is connected press C8 at the front panel to quickly save the current screen image under the root directory of the USB
71. alue takes the trigger position as reference and Y value takes the channel GND as reference The horizontal or vertical difference between cursor A and B BX AX or BY AY The reciprocal of the horizontal difference between cursor A and B 1 dX If needed please refer to the following steps to modify the parameters of manual cursor measurement 1 Select Cursor Type Press Type to select X or Y The X cursors are a vertical dotted line cursor A and a vertical solid line cursor B and are usually used to measure time parameters The voltage cursors are a horizontal dotted line cursor A and a horizontal solid line cursor B and are usually used to measure voltage parameters 2 Select Measurement Source Press Source to select the waveform of the analog channels CH1 CH4 or math operation results MATH for measurement 6 30 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL 3 Adjust the Cursor Position note that you can also press 42 continuously to switch the current cursor Adjust cursor A press CursorA and use 4 amp 2 to adjust the position of cursor A During the adjustment the measurement result will change accordingly The adjustable range is limited within the screen Adjust cursor B press CursorB and use 2 to adjust the position of cursor B During the adjustment the measurement result will change accordingly The adjustable range is limited within the screen Adjust cursor A and B a
72. an the preset setup time or when the hold time AT2 is less than the preset hold time as shown in the figure below AT 1is the setup time 1 i AT2 IAT1 4 AT2is the hold time amp 3 Data Source Clock Source The edge type is The data type is H Trigger Type Press Type to select Setup Hold At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press DataSrc and ClkSrc to set the data sources of the data line and clock line respectively They can be set to CH1 CH4 and the current data sources are displayed at the upper right corner of the screen Edge Type Press Slope to select the desired clock edge type and it can be set to the rising edge or falling edge Data Type Press Pattern to set the effective pattern of the data signal to H high level or L low level DS1000Z User s Guide 5 21 RIGOL Chapter 5 To Trigger the Oscilloscope Setup Type Press SetupType to select the desired setup type Setup set the time that the data stays stable and constant before the clock edge appears Press Setup to set the setup time and the range is from 8 ns to 1 s Hold set the time that the data stays stable and constant after the clock edge appears Press Hold to set the hold time and the range is from 8 ns to 1 s e SetupHold set the time tha
73. as auto normal or single The corresponding status light of the current trigger mode turns on 5 26 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Trigger Setting Press Setting to set the trigger parameters trigger holdoff and noise rejection under this trigger type DS1000Z User s Guide 5 27 RIGOL Chapter 5 To Trigger the Oscilloscope Windows Trigger Option Windows trigger provides a high trigger level and a low trigger level The instrument triggers when the input signal passes through the high trigger level or the low trigger level Trigger Type Press Type to select Windows At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 as the Trigger Source The current trigger source is displayed at the upper right corner of the screen Note select channel with signal input as trigger source to obtain stable trigger Windows Type Press WndType to select the kind of edge of the input signal on which the oscilloscope triggers e Ex trigger on the rising edge of the input signal when the voltage level is greater than the preset high trigger level e Ba trigger on the falling edge of the input signal when the voltage level is lower than the preset low trigger level e F trigger on any edge of the input signal when the voltage level meets the preset trigger level T
74. ass Fail Test Enable Test OFF Source CH1 Operate OFF X Mask 0 24 div 13 16 DS1000Z User s Guide Chapter 13 Store and Recall RIGOL Y Mask 0 48 div Statistic Display OFF Stop On Output OFF Output Fail Aux Output OFF System Setting Vertical Expansion Ground Power On Set Default Math Operation Setting MATH Operation A B Display OFF Source A CH1 Source B CH1 Offset 0v Scale 500 mV A B Display OFF Source A CH1 Source B CH1 Offset OV Scale 500 mV A B Display OFF Source A CH1 Source B CH1 Offset 0v Scale 500 mU AB Display OFF Source A CH1 Source B CH1 Offset 0v Scale 500 mU FFT Display OFF DS1000Z User s Guide 13 17 RIGOL Chapter 13 Store and Recall Source CH1 Offset 0 dBV Scale 500 mdBV Center 5 MHz Hz Div 5 MHz Scale 20 dBV View Half Unit dB dBm A amp amp B Display OFF Source A CH1 Source B CH1 Offset 0U Scale 500 mU Threshold A 0 V Threshold B OV AJ B Display OFF Source A CH1 Source B CH1 Offset OU Scale 500 mU Threshold A OV Threshold B OV A B Display OFF Source A CH1 Source B CH1 Offset 0U Scale 500 mU Threshold A OV Threshold B OV IA Display OFF Source A CH1 Source B CH1 13 18 DS1000Z User s Guide
75. ation trigger and the range is from 8 ns to 10 s lt trigger when the duration of the pattern is lower than the preset time Press Time to set the duration of duration trigger and the range is from 8 ns to 10 s e lt gt trigger when the duration of the pattern is lower than the upper limit of the preset time and greater than the lower limit of the preset time Press Upper Limit to set the upper limit of the duration of duration trigger and the range is from 16 ns to 10 s Press Lower Limit to set the lower limit of the duration of duration trigger and the range is from 8 ns to 9 99 s Note that the time lower limit must be lower than the time upper limit Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameters trigger holdoff and noise rejection under this trigger type Trigger Level Use TRIGGER LEVEL to modify the level For details please refer to the description of Trigger Level on page 5 9 Note that the trigger level of each channel needs to be set respectively 5 20 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Setup Hold Trigger Trigger when the internal state of the setup or hold time relative to the clock edge is changed by the logic data input namely trigger when the setup time AT1 is less th
76. attern of the channel selected to Don t Care namely this channel is not used as a part of the pattern When both the channels in the pattern are set to Don t Care the oscilloscope will not trigger or Ba set the pattern to the rising or falling edge of the channel selected DS1000Z User s Guide 5 17 RIGOL Chapter 5 To Trigger the Oscilloscope Note only one rising or falling edge can be specified in the pattern If one edge item is currently defined and then another edge item is defined in another channel in the pattern the former edge item defined will be replaced by X Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameters trigger holdoff and noise rejection under this trigger type Trigger Level Use TRIGGER LEVEL to modify the level For details please refer to the description of Trigger Level on page 5 9 Note that the trigger level of each channel needs to be set respectively 5 18 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Duration Trigger Identify a trigger condition by looking for the duration of a specified pattern This pattern is a logical AND combination of the two channels Each channel can have a value of high H low L or don t care X The instrument triggers when the duratio
77. ay instrument to measure the frequency of the 1 12 DS1000Z User s Guide Chapter 1 Quick Start RIGOL signal and the result is equal to the current capture rate Pass Fail there will be output a negative pulse signal when failed waveforms are detected by the oscilloscope Connect this signal to other control systems to view the test result conveniently There will be output a 3 3 V CMOS high level when no failed waveform is detected by the oscilloscope 5 Signal Output When the output of Sourcel and Source2 are enabled the signal currently set can be output to the analog input terminal of the oscilloscope or external devices connected to them through the Source1 and Source2 connectors at the rear panel 6 Lock Hole You can lock the instrument to a fixed location using the security lock please buy it yourself via the lock hole 7 Fuse If a new fuse is required please use the specified fuse 250V T2A a Turn off the instrument and remove the power cord b Insert a straight screwdriver into the slot at the power socket and prize out the fuse seat gently c Take out the fuse and replace it with specified fuse and then install the fuse seat to the original position 8 AC Power Socket AC power input terminal The power requirements of this oscilloscope are 100 240 V 45 440 Hz Use the power cord provided with the accessories to connect the instrument to AC power Then you can press the power key at the front panel to s
78. bits BitO Bit1 Bit15 Specify data channel for each bit First press Bit X to select the bit that needs to specify channel The default 7 2 DS1000Z User s Guide Chapter 7 Protocol Decoding RIGOL is 0 and the range available is always 1 smaller than the bus bits For example when the bus bits is 16 the range available is 0 1 15 Next press CH to specify a channel source for the bit currently selected in Bit X 4 Analog Channel Threshold Setting To judge logic 1 and logic 0 of the buses you need to set a threshold for each analog channel CH1 CH4 When the signal amplitude is greater than the preset value it is considered as 1 otherwise 0 y Threshold Level Press gt Decode Options gt Auto Thre to turn the auto threshold on or off When the auto threshold is turned on the instrument will calculate the center point according to the current waveform trace automatically as the threshold of each channel before decording When the auto threshold is turned off you can press Thre Set to turn the auto setting menu Press CH1 CH2 CH3 CH4 and use to set the threshold of each channel Press 50 to set the current threshold to 50 of the current waveform trace 5 Display related Setting Press Format to set the display format of the bus to Hex Decimal Binary ASCII or LINE Note that LINE format is displayed the acyual value of the bus in a binary number form and the
79. ce A and B point by point and display the results Press gt Math gt Operator to select AxB Press Display to turn on or off the multiplication operation function Press Source Aand Source B to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use to adjust the vertical offset of the operation result DS1000Z User s Guide 6 3 RIGOL Chapter 6 To Make Measurements Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results Division Divide the waveform voltage values of signal source A by that of source B point by point and display the results It can be used to analyze the multiple relationships of wavef
80. ce to obtain stable trigger Edge Type Press Slope to select the type of the first edge of the input signal that passes through the trigger level e EJ start timing when the rising edge of the input signal passes through the trigger level e E start timing when the falling edge of the input signal passes through the trigger level e F3 start timing when any edge of the input signal passes through the trigger level DS1000Z User s Guide 5 23 RIGOL Chapter 5 To Trigger the Oscilloscope Timeout Time Press TimeOut to set the timeout time of timeout trigger and the range is from 16 ns to 10 s Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameters trigger holdoff and noise rejection under this trigger type Trigger Level Use TRIGGER LEVEL to modify the level For details please refer to the description of Trigger Level on page 5 9 5 24 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Runt Trigger Option This trigger mode is used to trigger pulses that pass through one trigger level but fails to pass through the other trigger level as shown in the figure below Positive Runt Pulse High level et oe oe oe oe ne as Cae ce Seen Sone Memes Low Level 4 4 4 t 4
81. channels CH1 CH2 CH3 or CH4 Press Offset and use amp 2 to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORI ZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results 6 16 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL Absolute Value Calculate the absolute value of specified signal source point by point and display the results Press MATH Math gt Operator to select abs Press Display to turn on or off the absolute value operation function Press Source to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use amp 2 to adjust the vertical offset of the operation result Press Scale and use
82. d the oscilloscope will stop the test and enter the STOP state At this point the results of the test remain the same on the screen if display is turned on and only one pulse is output from the Trigger Out connector if enabled at the rear panel OFF the oscilloscope will continue with the test even though failed waveforms are detected The test results on the screen will update continuously and a pulse will be output from the Trigger Out connector at the rear panel each time a failed waveform is detected Press Output to select Ea or Kd e L failed waveforms are detected there are display and output but the beeper does not sound e iH failed waveforms are detected there are display and output and the beeper sounds not related to the on off state of the sound Press AuxOutput to quickly turn ON or OFF the output of test results from the Trigger Out connector at the rear panel You can also press gt AuxOutput and select PassFail to set this output DS1000Z User s Guide 9 3 RIGOL Chapter 9 Pass Fail Test To Save the Test Mask Users can save the current test mask to the internal Flash memory or external USB storage device The file format of the test mask file is pf The internal memory can store at most 10 test mask files LocalPF pf Press Save to enter the file store interface Please refer to the relative descriptions in 13 Store and Recall to save the test
83. d on the right of the endian display when the bus display is turned on and the default is 8 Press DataSrc to select Trace or Memory as the data source Press Range to select Full or User When Full is selected the instrument will determine the decoding range according to the current selection of the current data source when User is selected press Start to set the start point of the decoding and the range available is from 0 to end point 1 and press End to set the end point of the decoding and the range available is from start point 1 to 1199 7 Address I nformation during Decoding In 12C bus the front part of each frame of data contains the address information and blue patches are used to represent address ID In the ID Write is used to represent writing address and Read is used to represent reading address Press ADDR to select Normal or R W when R W is selected R W bit will be as a part of the address value in the Address DS1000Z User s Guide 7 13 RIGOL Chapter 7 Protocol Decoding 8 Error nformation during Decoding When the ACK ACKnowledge Character is not met error marks as shown in the figure below will be displayed ACK 1 7 14 DS1000Z User s Guide Chapter 7 Protocol Decoding RIGOL SPI Decoding Option SPI serial bus consists of clock line SCLK and data line SDA
84. de according to the input signal to make the waveform display easy to observe and measure 2 2 DS1000Z User s Guide Chapter 2 To Set the Vertical System RIGOL Channel Coupling Set the coupling mode to filter out the undesired signals For example the signal under test is a square waveform with DC offset When the coupling mode is DC the DC and AC components of the signal under test can both pass the channel When the coupling mode is AC the DC components of the signal under test are blocked When the coupling mode is GND the DC and AC components of the signal under test are both blocked Press CH1 gt Coupling and use 2 to select the desired coupling mode the default is DC The current coupling mode is displayed in the channel label at the bottom of the screen You can also press Coupling continuously to switch the coupling mode Bandwidth Limit Set the bandwidth limit to reduce display noise For example the signal under test is a pulse with high frequency oscillation When bandwidth limit is disabled the high frequency components of the signal under test can pass the channel Enable bandwidth limit and limit the bandwidth to 20 MHz the high frequency components that exceed 20 MHz are attenuated Press gt BW Limit and use amp 2 to enable or disable bandwidth limit the default is OFF When bandwidth limit 20 MHz is enabled the character B will be displayed in the
85. e 1 10 DS1000Z User s Guide Chapter 1 Quick Start Front Panel Overview I N DS11 z DUVI 10 11 RIGOL 13 14 15 16 17 Figure 0 9 Front Panel Overview Table 0 1 Front Panel Description Description Menu LCD z 9 Description Power Key USB HOST Multi function Knob Function Setting Menu Softkeys Function Menu Keys Analog Channel Input Area CLEAR VERTICAL AUTO HORI ZONTAL RUN STOP TRIGGER co j Oo U1 Rl WIN FR SINGLE Probe Compensation Signal Output Terminal Ground Terminal Help amp Print DS1000Z User s Guide RIGOL Chapter 1 Quick Start Rear Panel Overview 4 5 6 7 8 Figure 0 10 Rear Panel Overview 1 Handle Pull up the handle vertically for easy carrying of the instrument When you do not need the handle press it down 2 LAN Connect the instrument to the network via this interface for remote control This oscilloscope conforms to the LXI C class instrument standards and can quickly build test system with other instruments 3 USB DEVICE PictBridge printer or PC can be connected via this interface to print waveform data or control the instrument using PC software or user defined programming 4 Trigger Out Pass Fail Trigger Out the oscilloscope outputs a signal that can reflect the current capture rate of the oscilloscope at each trigger via this connector and connect the signal to a waveform displ
86. e adjustable range of the vertical scale is from 1 mV div to 10 V div Coarse adjustment take counterclockwise as an example set the vertical scale in 1 2 5 step namely 1 mV div 2 mV div 5 mV div 10 mV div 10 V div Fine adjustment further adjust the vertical scale within a relatively smaller range to improve vertical resolution If the amplitude of the input waveform is a little bit greater than the full scale under the current scale and the amplitude would be a little bit lower if the next scale is used fine adjustment can be used to improve the amplitude of waveform display to view signal details Note you can also press VERTICAL SCALE to quickly switch between Coarse and Fine adjustments DS1000Z User s Guide 2 5 RIGOL Chapter 2 To Set the Vertical System Vertical Expansion When using VERTICAL SCALE to change the vertical scale of the analog channel you can choose to expand or compress the signal vertically around the center of the screen or the ground point of the signal Press Utility gt System gt VerticalExp to select Center or Ground and the default is Ground Center when the vertical scale is modified the waveform will expand or compress around the center of the screen Ground when the vertical scale is modified the waveform ground level will remain at the same point on the screen and the waveform will expand or compress around this point Ampl
87. e displayed 5 Asshown in the figure above the distances from the crossing points of axis and the circle to the origin of the coordinates are approximately equal Thus the phase deviation angle 902xarcsin1 290 Note n YT mode the oscilloscope could use any sample rate within the guaranteed range to capture waveform The maximum sample rate of XY mode is 500 MSa s Generally reducing the sample rate properly could improve the display effect of Lissajous figure When XY mode is enabled Delayed Sweep will be disabled automatically Press X Y to select CH1 CH2 CH1 CH3 CH1 CH4 CH2 CH3 CH2 CH4 3 6 DS1000Z User s Guide Chapter 3 To Set the Horizontal System RIGOL CH3 CH4 and the two channels corresponding will be enabled automatically and disabled the other two channels at the same time X axis traces the voltage of the later channel of each option and Y axis traces the voltage of the former channel of each option The following functions are not available in XY mode Auto measure cursor measure math operation reference waveform delayed sweep vector display HORIZONTAL POSITION trigger control memory depth acquisition mode Pass Fail test and waveform record Method 2 Use the shortcut measurement function Please refer to Phase A gt B and Phase A Bt measurement functions of Delay and Phase on page 6 21 DS1000Z User s Guide 3 7 RIGOL Chapter 3 To Set the Horizontal System R
88. e following safety precautions carefully before putting the instrument into operation so as to avoid any personal injuries or damages to the instrument and any product connected to it To prevent potential hazards please use the instrument only specified by this manual Use Proper Power Cord Only the power cord designed for the instrument and authorized by local country could be used Ground The I nstrument The instrument is grounded through the Protective Earth lead of the power cord To avoid electric shock it is essential to connect the earth terminal of power cord to the Protective Earth terminal before any inputs or outputs Connect the Probe Correctly Do not connect the ground lead to high voltage since it has the isobaric electric potential as ground Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markers on the instrument and check your manual for more information about ratings before connecting Use Proper Overvoltage Protection Make sure that no overvoltage such as that caused by a thunderstorm can reach the product or else the operator might expose to danger of electrical shock Do Not Operate Without Covers Do not operate the instrument with covers or panels removed Use Proper Fuse Please use the specified fuses II DS1000Z User s Guide RIGOL Avoid Circuit or Wire Exposure Do not touch exposed junctions and components when the unit is powered Do Not Operate Wi
89. e of the signal under test to quickly capture the desired waveform This oscilloscope provides abundant advanced trigger functions which can help you to focus on the desired waveform details The contents of this chapter Trigger Source Trigger Mode Trigger Coupling Trigger Holdoff Noise Rejection Trigger Type Trigger Output Connector DS1000Z User s Guide 5 1 RIGOL Chapter 5 To Trigger the Oscilloscope Trigger Source Press MENU Source in the trigger control area TRIGGER at the front panel to select the desired trigger source Siganls input from CH1 CH4 and AC Line can all be used as trigger source Analog channel input Signals input from analog channels CH1 CH4 can all be used as the trigger source No matter whether the input of the channel selected is enabled the channel can work normally AC line The trigger signal is obtained from the AC power input of the oscilloscope This kind of signals can be used to display the relationship between signal such as illuminating device and power power supply device For example to stably trigger the waveform output from the transformer of a transformer substation which is mainly used in related measurement of the power industry 5 2 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Trigger Mode Trigger mode affects the way in which the oscilloscope searches for the trigger The following is the schematic diagram of the acquisiti
90. e right of the label display when the bus display is turned on and you can use Format to set the display format of the bus Press Endian to turn the endian display function on or off When it is turned on the current endian display will be displayed on the right of the format display when the bus display is turned on and you can use Endian to set the bus endian Press Width to turn the width display function on or off When it s turned on the data width of each frame will be displayed on the right of the endian display when the bus display is turned on and you can use Width to set the data width of each frame Press DataSrc to select Trace or Memory as the data source Press Range to select Full or User When Full is selected the instrument will determine the decoding range according to the current selection of the current data source when User is selected press Start to set the start point of the decoding and the range available is from 0 to end point 1 and press End to set the end point of the decoding and the range available is from start point 1 to 1199 DS1000Z User s Guide 7 17 Chapter 8 Reference Waveform RIGOL Chapter 8 Reference Waveform In actual testing process the waveform being tested can be compared with the reference waveform to judge the causes of failures The contents of this chapter To Enable REF Function To Select REF Source To Adjust REF Wav
91. e to select Delay At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source A Press SourceA to select CH1 CH4 as the trigger source of signal source A Edge A Press EdgeA to selec the trigger edge type of signal source A in delay trigger It can be set to the rising edge or falling edge Source B Press SourceB to select CH1 CH4 as the trigger source of signal source B Edge B Press EdgeB to select the trigger edge type of signal source B in delay trigger It can be set to the rising edge or falling edge 5 30 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Delay Type Press DelayType to set the time limit condition of delay trigger gt trigger when the time difference AT between the specified edges of source A and source B is greater than the preset time limit Press Time to set the delay time in delay trigger and the range is from 8 ns to 10 s lt trigger when the time difference AT between the specified edges of source A and source B is lower than the preset time limit Press Time to set the delay time in delay trigger and the range is from 8 ns to 10 s lt gt trigger when the time difference AT between the specified edges of source A and source B is greater than the lower limit of the preset time and lower than the upper limit of the preset time Press Upper Limit to set the upper limit of the delay time
92. ed window function and the default is Rectangle Table 0 1 Window Functions oe Waveforms Suitable for Characteristics Measurement Rectangle The best frequency Transient or short pulse the resolution signal levels before and after the the poorest amplitude multiplication are basically the resolution same similar to the situation Sine waveforms with the same when no window is amplitude and rather similar multiplied frequencies Wide band random noise with relatively slowly changing waveform spectrum Hanning Better frequency resolution Sine periodic and narrow band poorer amplitude random noise resolution Hamming A little bit better frequency Transient or short pulse the resolution than Hanning signal levels before and after the multiplication are rather different DS1000Z User s Guide 6 7 RIGOL Chapter 6 To Make Measurements 8 10 Blackman The best amplitude Single frequency signal search resolution for higher order harmonics the poorest frequency resolution Flattop Measure signal preciselly The signal that no accurate reference but require accurate measurements Triangle Better frequency resolution Narrowband signal with strong interference noise Set the view Mode Press View to select Half default or Full display mode Harf the source channel and the FFT operation results are displayed separately The time domain and frequency domain s
93. eform Display To Save to Internal Memory To Set the Color To reset the REF waveform To Export to I nternal or External Memory To I mport from I nternal or External Memory DS1000Z User s Guide 8 1 RIGOL Chapter 8 Reference Waveform To Enable REF Function Press REF in the vertical control area VERTICAL at the front panel to enable the REF function Note that when the time base is in XY mode REF function can not be enabled DS1000Z provides 10 reference waveform channels Press Channel and use to set the desired reference channel to on or off and a channel icon for example 88 of the channel enabled will be display at the left side of the screen grid When the REF function is enabled you can select different color for each reference waveform set the source of each reference channel adjust the vertical scale and position of the reference waveform and save the reference waveform to internal or external memory as well as recall it when needed For details please refer to the introductions below To Select REF Source Press Current and use 2 to select any of the reference channels Ref1 to Ref10 enabled and then press Source to specify a reference source CH1 CH4 or MATH for this channel 8 2 DS1000Z User s Guide Chapter 8 Reference Waveform RIGOL To Adjust REF Waveform Display To adjust the reference waveform specified in Current Press REF to enable the REF function Then press Offset and use a
94. eft corner of the screen in the following mode The X value at cursor A AX take the trigger position as reference and s or Hz when measuring FFT waveform as its unit The Y value at cursor A AY take the channel GND as reference and use the same unit as the current source The X value at cursor B BX take the trigger position as reference and s or Hz when measuring FFT waveform as its unit The Y value at cursor B BY take the channel GND as reference and use the same unit as the current source The horizontal difference between cursor A and B BX AX The vertical difference between cursor A and B BY AY The reciprocal of the horizontal difference between cursor A and B 1 dX If needed please refer to the following steps to modify manual cursor track measurement parameters DS1000Z User s Guide 6 33 RIGOL Chapter 6 To Make Measurements Select Measurement Source Press Cursor A to select the waveform of analog channels CH1 CH4 or math operation results MATH as the measurement source of cursor A only channels enabled are available You can also select None namely do not use cursor A Press Cursor B to select the waveform of analog channels CH1 CH4 or math operation results MATH as the measurement source of cursor B only channels enabled are available You can also select None namely do not use cursor B Adjust Cursor Position note that you can als
95. ele te Louie E deban DEL E de v Tent yertre a Hbi Ap ARP digi LE 12 19 Chapter 13 13 Store and Recall wicsisecisesisecssasssesisesivesscestsessstensesans 13 1 Ore cca mc 13 2 cer T Y 13 3 Internal Storage and Recalls uai poU FER Mau EUER ER RUR MRa ERR CDM eR 13 5 External Storage and Recall i52 caesa sec sar xia ex eka rax Ud rU HIA RR Ko cR 13 6 Disk Management oar i eos d epic Ela E FERRO FARA ENDE dea ERI US 13 7 To Select Fie TYDE aieo do e ERO ED AM AE ee 13 8 Te Create a New File or Folder icio cporibeibp d ERO QU eS ME ERE IERR EE RU REQUE 13 9 To Delete a File or Folder seeeeem 13 12 To Rename a File or Folder seseeen He 13 13 To Clear the Local MEMON Arr 13 13 POCUONY E E E E E E E T 13 14 Chapter 14 14 System Function Setting sssssssssnnnnnnnnnnnnnnnnnnnnnnnn 14 1 Remote Interface COnfiguration cccccceeccsseccceneeceeeeeeeeeeeesaeeseseeessaeess 14 2 ESdE She cT 14 2 DEBE Soo qu MM MM d DAMM E MM 14 6 XX DS1000Z User s Guide Ea E NEEE O oit ial poa AM bbb id a RARE M a aO UM nied anna 14 7 PONG 14 7 PTT OAS esse tupittdsuda scopi pIe a ONE ergs 14 7 icu MOMAN DP O T 14 8 Pon on Recdlinsdbdeboribe uei id RH EI P IQ MAI MM IM DM 14 8 lames T T I 14 9 Option MarnsgemeblE usas acp tr err Le Haus era ua bea ERR ORE ERE ERN 14 10 Chapter 15 15 Remote Control uus casi eai aided ied iki va cun i
96. electrical and electronic equipment WEEE 2 Product End of Life Handling The equipment may contain substances that could be harmful to the environment or human health In order to avoid release of such substances into the environment and harm to human health we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately Please contact your local authorities for disposal or recycling information X DS1000Z User s Guide RIGOL DS1000Z Series Overview DS1000Z is a high performance digital oscilloscope developed on the basis of the UltraVision technique DS1000Z featuring rather deep memory depth ultra wide dynamic range superb waveform capture rate and all round trigger functions is an invaluable debug instrument in various fields such as communication cosmonautics national defense embedded system computer research and education and is the one with the most complete functions and most outstanding specification among the digital oscilloscopes with lower than 100 MHz bandwidth Main features e 100 MHz and 70 MHz bandwidth UltraVision technique 1 GSa s maximum real time sample rate 30 000 wfms s dots display waveform capture rate Real time hardware waveform recording waveform playback functions Up to 60 000 frames of waveform can be recorded e 24 Mpts maximum memory depth option and 12 Mpts standard memory depth e Mult
97. els CH1 CH2 CH3 or CH4 Press Offset and use to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Tre A and use 2 to set the threshold of source A in logic operation Press Tre B and use 2 to set the threshold of source B in logic operation Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Sens to set the sencitivity of the operation results and the range available is 0 div to 0 96 div Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORI ZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results DS1000Z User s Guide 6 11 RIGOL Chapter 6 To Make Measurements NOT Operation Perform logic operation on specified sources waveform point by point and display the results In operation when the voltage value of the source cha
98. ent waveform trace automatically as the threshold of each channel before decording When the auto threshold is turned off you can press Thre Set to turn the auto setting menu Press CH1 CH2 CH3 CH4 and use to set the threshold of each channel Press 50 to set the current threshold to 50 of the current waveform trace DS1000Z User s Guide 7 7 RIGOL Chapter 7 Protocol Decoding 8 Display related Setting Press Format to set the display format of the bus to Hex Decimal Binary ASCII or LINE Note that LINE format is displayed the acyual value of the bus in a binary number form and the order is consistent with the bus transmission sequence This format is only valid for the serial bus because the serial bus has the difference of bit sequence of LSB and MSB if bit sequence of the bus is selected MSB the LINE format is the same to the binary format Press Pos and use to adjust the vertical display position of the bus 9 Decoding Configuration Press Decoding1 Configure to turn the decoding configuration submenu on Press Label to turn the label display function on or off When it is turned on the bus label will be displayed at the upper left of the bus when the bus display is turned on Press Line to turn the bus display function on or off When it is turned on the bus display will be displayed on the screen and you can use Pos to adjust the vertical display position of the bus Press Format to turn the format dis
99. enter the serial number activation operation menu Editor press this softkey to turn on the serial number input interface as shown in the figure below Use to select the characters on the virtual keyboard and press down the knob to input the character Serial Number Input Area Character Selecting Area Backspace press this softkey to delete the characters in the Serial Number Input Area from the right to the left Clear press this softkey to clear all the characters in the Serial Number Input Area Apply press this softkey and the oscilloscope will activate the corresponding option using the serial number currently input 14 10 DS1000Z User s Guide Chapter 15 Remote Control RIGOL Chapter 15 Remote Control The oscilloscope can be controlled remotely mainly through the following two methods User defined programming Users can program and control the oscilloscope by using the SCPI Standard Commands for Programmable Instruments commands For more information about the commands and programming refer to the Programming Guide Use PC software provided by RIGOL or other manufacturers Users can use the PC software Ultra Sigma of RIGOL Measurement amp Automation Explorer of NI National Instruments Corporation or Agilent I O Libraries Suite of Agilent Agilent Technologies Inc to send commands to control the oscilloscope remotely This oscilloscope can communicate with PC through USB and LAN instrument buses Th
100. eshooting Introduce how to deal with common failures of the oscilloscope Chapter 17 Specifications Provide the specifications and general specifications of the oscilloscope Chapter 18 Appendix Provide common information such as options and accessories Format Conventions in this Manual Front panel key denoted by the format of Text Box Button Name Bold for example Storage Menu softkey denoted by the format of Character Shading Menu Word Bold for example Storage Operation steps denoted by the arrow gt for example Storage gt Storage Cross reference denoted by the blue font with bold and underline for example 12 Signal Source Knob Logo Knob Logo Knob Multi function VERTICAL SCALE Vertical Scale Knob Knob HORIZONTAL Horizontal VERTICAL Vertical Position SCALE m Scale Knob POSITION Knob HORIZONTAL Horizontal TRIGGER LEVEL Trigger Level POSITION Position Knob Knob XIV DS1000Z User s Guide Content Conventions in this Manual This manual takes DS1104Z S for example and the descriptions here have contained all the functions and performances of other models DS1000Z series includes the following models RIGOL Model Analog bandwidth Channels Cahnnels for signal source DS1104Z 100 MHz 4 B DS1074Z 70 MHz 4 NS DS1104Z S 100 MHz 4 2 DS1074Z S 70 MHz 4 2 DS1000Z User s Guide XV RIGOL
101. espective period RIGOL guarantees the free replacement or repair of products which are approved defective To get repair service please contact with your nearest RIGOL sales and service office RIGOL does not provide any other warranty items except the one being provided by this summary and the warranty statement The warranty items include but not being subjected to the hint guarantee items related to tradable characteristic and any particular purpose RIGOL will not take any responsibility in cases regarding to indirect particular and ensuing damage 18 2 DS1000Z User s Guide Chapter 18 Appendix RIGOL Appendix C Any Question or Comment If you have any question or comment on our document please mail to service rigol com DS1000Z User s Guide 18 3 Index RIGOL Index x DUtyiic erre ep 20 High Resolution 4 SWIATA kirng tof ts 20 12C Decoding 11 DUM eaen aa calves 20 IP Address iana ee ee 3 d MICE or c Pots o e es 20 MAD ee sy cR oen eo e Re dott 5 Acquisition Mode sssss 2 Manual Mode cce 30 Additlon treo n 2 Memory Depth ccr 7 AUt IP tete edere s 3 Multiplication eeeeese 3 Auto Mode ccce 35 Network Status sesssssse 2 Average cese re tein 2 Notmal z ise eee res 2 Bandwidth Limit ssssssss 3 Nth Edge Trigger ssssse 32 Blackmansz s eve abi nee 8 OvershO0t iae terea 22 Channel Coupling
102. ess 4 Current Frame Press Current and use 2 to set the current frame the default is the maximum number of frames recorded During the setting the screen will display the corresponding waveform of the current frame synchronously namely manual playback The contents of this chapter m Playback Setting m Record Setting DS1000Z User s Guide 10 1 RIGOL Chapter 10 Waveform Record Playback Setting Waveform playback can play back the waveforms currently recorded At this point the information as shown in the figure below is displayed at the upper right corner of the screen the data on the left indicates the specific frame currently displayed on the screen and during the playback this value would change continuously The data on the right indicates the maximum number of frames that can be recorded currently Please refer to the following descriptions to set the playback parameters 1 Play Mode Press Mode to set the playback mode to cycle or single e C cycle playback Play from the start frame to the end frame and then repeat until you stop it manually e b lK single playback Play from the start frame to the end frame and then stop 2 Play Direction Press Dir to set the playback direction to forward direction or inverse direction forward direction Play from the start frame to the end frame e inverse direction play from end frame to start frame 3 Interval Press Interval and use 2 to set the time inte
103. f the first ramp waveform pulse in the even field Video Standard Press Standard to select the desired video standard NTSC the field frequency is 60 fields per second and the frame frequency is 30 frames per second The TV sweep line is 525 with the even field goes first and the odd field follows behind DS1000Z User s Guide 5 15 RIGOL Chapter 5 To Trigger the Oscilloscope PAL the frame frequency is 25 frames per second The TV sweep line is 625 with the odd field goes first and the even field follows behind SECAM the frame frequency is 25 frames per second The sweep line is 625 with interlacing sweep e HDTV HDTV consists of 480P and 576P display formats The specified video standards are as follows 480P the frame frequency is 60 frames per second the TV sweep line is 525 line by line sweep the line frequency is 31 5 kHz 576P the frame frequency is 60 frames per second the TV sweep line is 625 line by line sweep Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameter noise rejection under this trigger type Trigger Level Use TRIGGER LEVEL to modify the level For details please refer to the description of Trigger Level on page 5 9 5 16 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope R
104. ffer and display the acquisition memory Use normal trigger mode for low repetitive rate signals or when auto trigger is not required Note in this mode pressing can generate a trigger signal forcefully Single When this mode is selected the backlight of turns on The oscilloscope waits for a trigger and displays the waveform when the trigger condition is met and then stops Note in this mode pressing can generate a trigger signal forcefully 5 4 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Trigger Coupling Trigger coupling decides which kind of components will be transmitted to the trigger circuit Please distinguish it with Channel Coupling DC allow DC and AC components into the trigger path AC block all the DC components and attenuate signals lower than 75 kHz LF Reject block the DC components and reject the low frequency components lower than 75 kHz HF Reject reject the high frequency components higher than 75 kHz Press IMENU 2 Setting gt Coupling in the trigger control area TRIGGER at the front panel to select the desired coupling type the default is DC Note that trigger coupling is only valid in edge trigger DS1000Z User s Guide 5 5 RIGOL Chapter 5 To Trigger the Oscilloscope Trigger Holdoff Trigger holdoff can be used to stably trigger the complex waveforms such as pulse series Holdoff time is the amount of time that the oscilloscope waits befo
105. g from shipment RIGOL would not be responsible for free maintenance rework or replacement of the unit Inspect the instrument In case of any damage or defect or failure notify your RIGOL sales representative Check the Accessories Please check the accessories according to the packing lists If the accessories are incomplete or damaged please contact your RIGOL sales representative 1 2 DS1000Z User s Guide Chapter 1 Quick Start RIGOL Appearance and Dimensions 7 313 1 yal N D QS ZY ce B g B dgo Osi ce gt Og a A o7 gagy Z he WIA oJ 9 9 m 1 Figure 0 1 Front View Unit mm Se FT _ _ l I Hs i LJT g 3 i LE LCD te t ERE WAT m Figure 0 2 Top View Unit mm DS1000Z User s Guide 1 3 RIGOL Chapter 1 Quick Start To Prepare the Oscillosco
106. ger Trigger on the trigger threshold of the specified edge of the input signal Trigger Type Press Type to select Edge At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 or AC Line as the Trigger Source The current trigger source is displayed at the upper right corner of the screen Note select channel with signal input as trigger source to obtain stable trigger Edge Type Press Slope to select the kind of edge of the input signal on which the oscilloscope triggers The current edge type is displayed at the upper right corner of the screen e Ex trigger on the rising edge of the input signal when the voltage level meets the preset trigger level e t trigger on the falling edge of the input signal when the voltage level meets the preset trigger level e EEA trigger on the rising and falling edges of the input signal when the voltage level meets the preset trigger level Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameters trigger coupling trigger holdoff and noise rejection under this trigger type Trigger Level Trigger occurs only when the signal reaches the preset trigger level Use TRIGGER
107. ger the Oscilloscope RIGOL Video Trigger Trigger on the standard video signal field or line of NTSC National Television Standards Committee PAL Phase Alternating Line SECAM sequential color with memory or HDTV High Definition Television Trigger Type Press Type to select Video At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 as the Trigger Source The current trigger source is displayed at the upper right corner of the screen Note select channel with signal input as trigger source to obtain stable trigger Video Polarity Press Polarity to select the desired video polarity The polarities available are normal polarity Ill and inverted polarity Ml Sync Press Sync to select the desired sync type All Lines trigger on all the horizontal sync pulses Line Num for NTSC and PAL SECAM video standards trigger on the specified line in the odd or even field for HDTV video standard trigger on the specified line Note that when this sync trigger mode is selected you can modify the line number using in the Line Num menu with a step of 1 The range of the line number is from 1 to 525 NTSC 1 to 625 PAL SECAM 1 to 525 480P 1 to 625 576P e Odd field trigger on the rising edge of the first ramp waveform pulse in the odd field Even field trigger on the rising edge o
108. h of runt trigger and the range is from 8 ns to 9 99 s Note the lower limit of the pulse width must be lower than the upper limit Vertical Window Press Vertical to select the desired vertical window type Note that under the Runt trigger menu you can press the trigger level knob continuously to switch among different vertical window types You can select the boundary of the trigger level to be set and then use Trigger gt LEVEL to adjust the trigger level During the adjustment two orange trigger level lines and trigger marks Kl and Ei appear on the screen and move up and down with the rotation of the knob At the same time the current trigger level values are displayed at the lower left corner of the screen The trigger level lines and trigger marks disappear after you stop rotating the knob for 2 s The adjustment mode of the trigger level differs when different vertical window is selected e E only adjust the upper limit of the trigger level During the adjustment the Up Level changes accordingly and Low Level remains unchanged e EE only adjust the lower limit of the trigger level During the adjustment the Low Level changes accordingly and the Up Level remains unchanged e EEJ adjust the upper and lower limits of the trigger level at the same time During the adjustment the Up Level and Low Level change accordingly Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type
109. h of the oscilloscope Use HORIZONTAL gt SCALE to modify this parameter 6 Waveform Memory Provide the schematic diagram of the memory position of the waveform currently on the screen waveform on the 7 Trigger Position Display the trigger position of the waveform in the waveform memory and on the screen 8 Horizontal Position Use HORIZONTAL gt POSITI ON to modify this parameter Press down the knob to automatically set the parameter to zero 9 Trigger Type Display the currently selected trigger type and trigger condition setting Different labels are displayed when different trigger types are selected For example M represents triggering on the rising edge in Edge trigger 10 Trigger Source Display the trigger source currently selected CH1 CH4 or AC Line Different labels are displayed when different trigger sources are selected and the color of the trigger parameter area will change accordingly For example 1 denotes that CH1 is selected as the trigger source 11 Trigger Level e at the right of the screen is the trigger level label and the trigger level value is displayed at the upper right corner of the screen When using TRIGGER LEVEL to modify the trigger level the trigger level value will change with the up and down of E Note in slope trigger runt trigger and windows trigger there are two trigger level labels El and Erg 12 CH1 Vertical Scale Display the voltage value per grid of CH1 waveform ve
110. hase Use the oscilloscope to sample and display the waveforms of the two channels and you will see that the phase of the two waveforms shown on the oscilloscope changed At this point press AlignPhase and the waveforms on the oscilloscope will restore the current phase deviation of the two channels 8 Modulation Press Modulation to turn the modulation function on or off For detailed 12 10 DS1000Z User s Guide Chapter 12 Signal Source RIGOL information about modulation function please refer to Modulation 9 To set impedance Press Impedance to set the output impedance of the current signal HighZ and 500 can be selected DS1000Z User s Guide 12 11 RIGOL Chapter 12 Signal Source To Output Arbitrary Waveform DS2000A allow users to define arbitrary waveforms and to save them to the internal or external memory The internal memory can store 10 arbitrary waveforms at most 1 to 16384 points can be included in the user defined waveforms namely 1 pts to 16 kpts Press Src1 Setup to enter the waveform setting interface Press Wave to select Arb at this point you can edit arbitrary waveforms 1 2 3 4 Output Press Output to turn the signal output on or off To set frequency Press Frequency to set the frequency of the current signal and the range available is from 100 mHz to 1 MHz Method one Rotate 4 directly to set the desired frequency value Method two Press 2 to input desi
111. hat the USB storage device is connected correctly Press Storage gt DiskManage and use 2 to select and open the external disk Disk D Use 44 to select the desired file or folder to rename and then press Rename to turn on the rename interface For specific operations please refer to the descriptions in To Create a New File or Folder To Clear the Local Memory Press gt DiskManage and select Local Disk then press FlashClear gt OK to delete all the files stored in the local memory At the same time the instrument will be resotred to the default setting DS1000Z User s Guide 13 13 RIGOL Factory Chapter 13 Store and Recall Press Storage 2 Default to return the oscilloscope to its factory state refer to the table below Table 0 1 Factory Parameter Factory Horizontal Setting HORI ZONTAL Vertical Setting VERTI CAL Acquisition Setting Acquire Trigger Setting TRI GGER Display Setting Display Signal Source Cursor Settin Storage Settin Utili Math O Protocol Decodin Cursor Storage Function Settin ration Settin MATH Decode1 Decode2 Utili MATH Operation Reference Waveform Setting REF Horizontal Setting HORI ZONTAL Horizontal Time Base 1 us Horizontal Offset 0s Delayed Sweep OFF Time Base Type YT Vertical Setting VERTI CAL Vertical Scale 200 mV Vertical Offset OV CH1 Switch ON CH2 Switch ON CH3 Switch ON
112. he item that needs to get help for example Band Width Press the knob to get the corresponding help information in the Help Display Area Use amp 2 to select To Button and then press the knob to switch to Button mode 1 24 DS1000Z User s Guide Chapter 2 To Set the Vertical System RIGOL Chapter 2 To Set the Vertical System The contents of this chapter To Enable the Channel Channel Coupling Bandwidth Limit Probe Ratio Waveform I nvert Vertical Scale Vertical Expansion Amplitude Unit Channel Label DS1000Z User s Guide 2 1 RIGOL Chapter 2 To Set the Vertical System To Enable the Channel DS1000Z provides 4 analog input channels CH1 CH4 and each channel can be controlled independently As the vertical system setting methods of the 2 channels are completely the same this chapter takes CH1 as an example to introduce the setting method of the vertical system Connect a signal to the channel connector of any channel for example CH1 and then press in the vertical control area VERTICAL at the front panel to enable CH1 Screen The channel setting menu is displayed at the right side of the screen and the channel label at the bottom of the screen as shown in the figure below is highlighted The information displayed in the channel label is related to the current channel setting After the channel is turned on modify the parameters such as the vertical scale the horizontal time base and the trigger mo
113. he vertical scale horizontal time base and trigger mode according to the input signal to realize optimum waveform display Note that auto setting requires that the frequency of the signal under test should be no lower than 50 Hz the duty cycle be greater than 196 and the amplitude be at least 20 DS1000Z User s Guide Chapter 1 Quick Start RIGOL mVpp If the parameters exceed these limits can t detect any signal would be displayed after pressing this key and the quick parameter measurement menu might not be displayed Adjust waveform brightness In non menu operation mode turn this knob to adjust the brightness of waveform display The adjustable range is from 096 to 10096 Turn clockwise to increase the brightness and counterclockwise to reduce Press down this knob to reset the brightness to 5096 You can also press gt Intensity and use the knob to adjust the waveform brightness Multifunction Knob the backlight goes on during operation In menu operation press any menu softkey and turn the knob to switch the desired submenu under this menu and then press down the knob to select the current submenu It can also be used to modify parameters and input filename In addition for DS1000Z S models oscilloscope in the source interface press the corresponding menu softkey and then press the knob the numeric keyboard will pop up on the screen and you can input the desired parameter value and unit directly using this knob
114. i degree gray scale display Low noise 1 mV div to 10 V div ultra wide vertical dynamic range 7 0 inches WVGA 800 480 160 000 color TFT LCD vivid picture low power consumption and long service life Adjustable brightness of analog channel waveform Auto setting of waveform display AUTO 15 kinds of trigger functions including multiple protocol triggers Standard parallel decoding and multiple serial decoding options Auto measurements of 24 waveform parameters and measurement functions with statistic Precise delayed sweep function Built in FFT function Pass Fail test function Multiple waveform math operation functions Built in dual channel 25 MHz signal source function only available for DS1000Z S e Standard configuration interfaces USB Device USB Host LAN and GPIB optional Conform to LXI C instrument standards Enable quick economic and efficient DS1000Z User s Guide XI RIGOL creation and reconfiguration of test system Support remote command control Embedded help enables easier information access Support multiple languages and Chinese English input Novel and delicate industrial design and easier operation XII DS1000Z User s Guide RIGOL Document Overview Chapter 1 Quick Start Provide information about preparations before using the instrument and a brief introduction of the instrument Chapter 2 To Set the Vertical System Introduce the functions of the vertical sy
115. ia eai a 15 1 Remote CO RE CR clo P 15 2 Remote Control via LAN c L 15 6 Chapter 16 16 Troubleshooting issiisiiirissrsnissnsisniraninsnsisssansainsnsnsaan 16 1 Chapter 17 BET mie oq PPEH 17 1 Chapter 18 15 AONE sshd 18 1 Appendix A Accessories and Options s e reenen 18 1 Appendix E Warran S eade ae E pRRG eerta d REPE RAE DD ea MEER Db Pad 18 2 Appendix C Any Question or Comment ssssssssseeee nne 18 3 Chapter 19 foo qt 1 DS1000Z User s Guide XXI Chapter 1 Quick Start RIGOL Chapter 1 Quick Start This chapter introduces the preparations when using the oscilloscope for the first time the front panel rear panel and user interface of the oscilloscope as well as the using method of the built in help system The contents of this chapter General I nspection Appearance and Dimensions To Prepare the Oscilloscope for Use Front Panel Overview Rear Panel Overview Front Panel Function Overview User I nterface To Use the Security Lock To Use the Built in Help System DS1000Z User s Guide 1 1 RIGOL Chapter 1 Quick Start General I nspection 1 Inspect the shipping container for damage Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has passed both electrical and mechanical tests The consigner or carrier shall be liable for the damage to instrument resultin
116. ic I P mode 14 4 DS1000Z User s Guide Chapter 14 System Function Setting RIGOL The address format of the domain name server is nnn nnn nnn nnn wherein the range of the first nnn is from 0 to 223 except 127 and the ranges of the other three nnn are from 0 to 255 You are recommended to ask your network administrator for an address available press DNS and use 2 to input the desired address Generally users do not need to set the DNS therefore this parameter setting can be ignored Tips When the three IP configuration types are all turned on the priority of the parameter configuration from high to low is DHCP Auto IP and Static IP The three IP configuration types can not be all turned off at the same time Apply the Network Parameter Setting Press Apply to validate the current network parameter setting Initialize the Network Parameters Press Initialize to return the network parameters to the default state MAC Address For each oscilloscope the MAC address is unique When attributing IP address for the oscilloscope the MAC address is usually used to identify the instrument VI SA Address Display the VISA address currently used by the oscilloscope DS1000Z User s Guide 14 5 RIGOL Chapter 14 System Function Setting USB Device This oscilloscope can communicate with PC or PictBridge printer via the USB Device interface at the rear panel Press Utility gt 10 Setting gt USB
117. identify the current measurement source according to the color of the icon The following figure is the result of frequency measurement of the input signal of CH1 Select OFF to disable the frequency counter measurement function 6 24 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL Measurement Setting 1 4 Source Selection Press Measure gt Source to select the desired channel for measurement CH1 CH4 The color of the parameter icons under IMENU at the left of the screen will change with the source selected Delayed Measurement Setting Specify the source A and source B in the measurement items Delay A gt BF and Delay A Bt Press Measure gt Setting gt Type gt Delay and then press SourceA and SourceB to set the two channel sources CH1 CH4 of delayed measurement respectively Phase Measurement Setting Specify the source A and source B in the measurement items Phase A gt B and Phase A Bt Press Measure gt Setting gt Type gt Phase and then press SourceA and SourceB to set the two channel sources CH1 CH4 of phase measurement respectively Threshold Measurement Setting Specify the vertical level in percentage being measured in the analog channel Measurements of all the time delay and phase parameters will be influenced by this setting Press Measure gt Setting gt Type gt Threshold and then Press Max and use to set the maximum
118. ignal is greater than the specified pulse width e EX trigger when the negative pulse width of the input signal is lower than the specified pulse width e EXER trigger when the negative pulse width of the input signal is greater than the specified lower limit of pulse width and lower than the upper limit of pulse width Pulse Width Setting In this oscilloscope positive pulse width is defined as the time difference between the two crossing points of the trigger level and positive pulse as shown in the figure below 5 10 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL an Nee Bue Trigger level Positive pulse width 1 LU pn e When the Pulse Condition is set to HBS EA BEN o EIE press Setting and use to input the desired value The range available is from 8 ns to 10 s e When the Pulse Condition is set to EREE or ISEI press Upper Limit and Lower Limit and use 2 to input the desired values respectively The range of the upper limit is from 16 ns to 10 s The range of the lower limit is from 8 ns to 9 99 s Note that the lower limit of the pulse width must be lower than the upper limit Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameters trigger holdoff and noise rejection under this trigger t
119. ignals are displayed clearly Full Screen the source channel and the FFT operation results are displayed in the same window to view the frequency spectrum more clearly and to perform more precise measurement Note in FFT mode and when MATH is the active channel you can also press HORI ZONTAL SCALE to switch between Half and Full Set the Vertical Scale The unit of the vertical axis can be dB dBm or Vrms which use logarithmic mode and linear mode to display vertical amplitude respectively If you need to display the FFT frequency spectrum in a relatively larger dynamic range dB dBm is recommended Press Unit to select the desired unit and the default is Vrms Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Tips Signals with DC components or deviation would cause error or deviation of the FFT waveform components To reduce the DC components set the Channel Coupling to AC To reduce the random noise and aliasing frequency components of repetitive or single pulse set the Acquisition Mode of the oscilloscope to Average 6 8 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL AND Operation Perform logic operation on specified sources waveform point by point and display the results In operation when the voltage value of the source channel is greater than the threshold of the corresponding channel it i
120. ime Bose oo T 3 4 TERE art the wie vo Dia des ath eget ust use ian wee anna M OPE DRM 3 4 2H o mec 3 5 abren t 3 8 Chapter 4 4 To Set the Sample System nene 4 1 Puuisdan NODE ccc v Ot Et EE HORAE CO ERE NO GER uN RERO Ai 4 2 BRUM oc cuatro EY bates DE ease ae ned ane EROR Mad Hd ET 4 2 EI CN T I E LU aia areas aaa 4 2 dz dui e csacuauiiabacs exndunda abies con tecivnastan den i 4 4 High ccsdrej isis PE 4 4 PON dr VPN EN TEL CN TRENT MT PETS 4 4 E MERIT RT D ree ere ne 007 01 0232 71 re terre OT 4 5 Memory DEDA asser vcdi d te EE PE EUER pee kr ER HE p E HE GrE ERR eae 4 7 Chapter 5 5 To Trigger the Oscilloscope e eene 5 1 Bi ge QR RR E TET 5 2 Tager Mode PN T T 5 3 big cab T oli NUT 5 5 Tite HOO otis incsuans Mewes OE KO EGER GEO D Kb EPA ca lae KR nn 5 6 deccm cer E iO DT T O 5 7 DS1000Z User s Guide XVII RIGOL Te STILE 5 8 Edge DEP CI MT a a Os 5 9 ui TOE anann m 5 10 Sope Nro STET 5 12 bino Ni ETT Lm TT 5 15 Pattern Tigga Lucis si terio crie cadherin cial OX RR ASR TR dide kar RE REPE 5 17 Duration Mager eo pad doe E EFE EG D E en RODA IER ERE EO ERR 5 19 So dale M gi o E T A mv 5 21 TS Tager OGIO eanna NV KR REI Tide 5 23 R nt moger Opon P M 5 25 Windows Tigger Opto m 5 28 Delay Tigger OPEN eT emp iea oiii 5 30 Nu Edge Trigger TLUUDIU abs icu v vp M UHR O
121. ing 3 Search device resource Start up the Ultra Sigma and click LAN The window as shown in the figure below is displayed Click as shown in Figure a and the software searches for the oscilloscope resources currently connected to the LAN and the resources found are displayed at the right of the window As shown in Figure b select the desired resource name and click BT to add it Note that if you want to remove the unwanted resource select the resource name and click as shown in Figure c Remove Manual Input LAN Instrument IP TEST J Add Auto detect of LAN Instrument Search Figure a 15 6 DS1000Z User s Guide Chapter 15 Remote Control RIGOL Remove RN Manual Input LAN Instrument IP TCPIP 1T2 18 3 16 INSTR TCPIP 2 3 4 INSTR Auto detect of LAN Instrument Search Figure b Rene Manual Input LAN Instrument IP TCPIP Auto detect of LAN Instrument Search Figure c 4 View device resource The resources found will appear under the RIGOL Online Resource directory as shown in the figure below LAN GPIB USB TMC RS232 IVI Config Verify All I 1 RIGOL Online R L 0S1104Z IVI C Ir Control Other 2 ch LAN instrument 5 Communication test Right click the resource name DS1104Z TCPIP 172 16 3 16 INSTR to select SCPI Panel Control to turn on the remote command control panel as shown in the figure below through which you can send commands
122. ion menu 1 Press Decode to turn on or off the decoding function 2 SCLK Setting Press CLK to select any channel CH1 CH4 as the clock channel 3 SDA Setting Press SDA to select any channel CH1 CH4 as the data channel Note that press Exchange to change the source of clock between the clovk source and data source DS1000Z User s Guide 7 11 RIGOL Chapter 7 Protocol Decoding 4 Analog Channel Threshold Setting To judge logic 1 and logic 0 of the buses you need to set a threshold for each analog channel CH1 CH4 When the signal amplitude is greater than the preset value it is considered as 1 otherwise 0 a Threshold Level Press MATH gt Decode Options gt Auto Thre to turn the auto threshold on or off When the auto threshold is turned on the instrument will calculate the center point according to the current waveform trace automatically as the threshold of each channel before decording When the auto threshold is turned off you can press Thre Set to turn the auto setting menu Press CH1 CH2 CH3 CH4 and use 42 to set the threshold of each channel Press 50 to set the current threshold to 50 of the current waveform trace 5 Display related Setting Press Format to set the display format of the bus to Hex Decimal Binary ASCII or LINE Note that LINE format is displayed the acyual value of the bus in a binary number form and the order is consistent with the bus transmission se
123. is chapter will give a detailed introduction of how to use Ultra Sigma to control DS1000Z remotely through various interfaces For the Ultra Sigma software please contact RIGOL salesmen or technical support The contents of this chapter BH Remote Control via USB B Remote Control via LAN DS1000Z User s Guide 15 1 RIGOL Chapter 15 Remote Control Remote Control via USB 1 Connect the device Connect the oscilloscope USB DEVICE with your PC using a USB cable 2 Install the USB driver This oscilloscope is a USBTMC device Assuming that your PC has already been installed with Ultra Sigma after you connect the oscilloscope to the PC and turn both on for the first time the oscilloscope is automatically configured to USB interface the New Hardware Wizard as shown in the figure below is displayed on the PC Please install the USB Test and Measurement Device driver following the directions in the wizard The steps are as follows Found New Hardware Wizard This wizard helps you install software for USB Test and Measurement Device If your hardware came with an installation CD lt 4 or floppy disk insert it now What do you want the wizard to do 1 Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue 2 Ce 15 2 DS1000Z User s Guide Chapter 15 Remote Control Found New Hardware Wizard Please choose your search and insta
124. is filled and continues to flow data through this buffer while it searches for the trigger While searching for the trigger the oscilloscope overflows the pre trigger buffer and the first data put into the buffer DS1000Z User s Guide 5 3 RIGOL Chapter 5 To Trigger the Oscilloscope is first pushed out First Input First Out FIFO When a trigger is found the pre trigger buffer would contain the data acquired just before the trigger If no trigger is found the oscilloscope will trigger forcefully If forceful trigger is invalid the oscilloscope still displays waveform but the waveform is not stable if forceful trigger is valid the oscilloscope displays stable waveform This trigger mode is applicable to low repetitive rate signals and unknown signal levels To display DC signals you must use auto trigger mode Note when the horizontal time base is set to 50 ms div or greater this trigger mode allows the absence of trigger signal Normal Display waveform when the trigger condition is met otherwise the oscilloscope holds the original waveform and waits for the next trigger In this mode the oscilloscope fills the pre trigger buffer first and then search for a trigger while at the same time continues filling data While searching for the trigger the oscilloscope overflows the pre trigger buffer and the first data put into the buffer is first pushed out FIFO When a trigger is found the oscilloscope will fill the post trigger bu
125. itude Unit Select the amplitude display unit for the current channel The available units are W A V and U When the unit is changed the unit displayed in the channel label will change accordingly Press gt Unit to select the desired unit and the default is V 2 6 DS1000Z User s Guide Chapter 2 To Set the Vertical System RIGOL Channel Label To identify different analog channels you can set another label for each channel such as ISI Press CH1 gt Label to enter the label modification interface you can use the built in label or input the label manually and the length of the label can not exceed 4 characters Note only English input method can be used for this operation Press Display to turn on or off the display of channel label and the default is CH1 Press Label Edit to enable the label editing interface as shown in the figure below Name Input Area Keyboard Upper Lower Case Switch For example editing the label for Sm Press Keyboard to select the Keyboard area Select Aa using amp 2 and press down 2 to switch it to A Select C using 42 and press down to input the character Use the same method to input hn1 To modify or delete the input character press Name to select the Name Input Area and use amp 2 to select the character to be modified or deleted Enter the desired character or press Delete to delete the character selected After finishing the input press OK to finish the modificati
126. l Resolution 14 bits Highest Frequency 25 MHz Standard Waveform Sine Square Pulse Triangle Noise DC DS1000Z User s Guide Chapter 17 Specifications RIGOL Arbitrary Since Exp Rise EXP Fall ECG Gauss Lorentz Waveform Haversine Sine Frequency Range 0 1 Hz to 25 MHz Flatness 0 5 dB relative to 1 kHz Harmonic Distortion 40 dBc Stray Non Harmonic 40 dBc Total Harmonic 1 Distortion Signal to Noise ration 40 dB Square Pulse Frequency Range 0 1 Hz to 15 MHz Rise Fall time lt 15 ns Overshoot lt 5 Duty Cycle 10 to 90 Duty Cycle 1 to 10 ns select the Resolution greater one Minimum Pulse Width 20 ns Pulse Width 10 ns or 5 bits select the Resolution greater one Jitter 500 ps Triangle Frequency Range 0 1 Hz to 100 kHz Linearity 1 Symmetry 0 to 100 Noise Bandwidth 25 MHz Internal Generated Frequency Range 0 1 Hz to 1 MHz waveforms Arbitrary Frequency Range 0 1 Hz to 10 MHz Waveforms Waveform Length 2 to 16k pts Frequency Accuracy 100 ppm lower than 10 kHz 50 ppm greater than 10 kHz Resolution 0 1 Hz or 4 bit select the greater one Amplitude Output Range 20 mVpp to 5 Vpp High resistance 10 mVpp to 2 5 Vpp 50 Q DS1000Z User s Guide 17 7 RIGOL DC Offset Chapter 17 Specifications Resolution 100 uV or 3 bit select the greater one Accuracy 2 1 kHz Range 2 5 V High resistance 1 25 V 50 Q
127. le data is lower than the actual signal frequency The most common aliasing is the jitter on fast edge KV DS1000Z User s Guide 4 5 RIGOL Chapter 4 To Set the Sample System 3 Waveform Leakage when the sample rate is too low the waveform rebuilt from the sample data does not reflect all the actual signal information Pulse disappeared 4 6 DS1000Z User s Guide Chapter 4 To Set the Sample System RIGOL Memory Depth Memory depth refers to the number of waveform points that the oscilloscope can store in a single trigger sample and it reflects the storage ability of the sample memory DS1000Z provides up to 24 Mpts memory depth option and 12 Mpts standard memory depth Trigger Point Pre sample Delayed Sample gt Memory Depth J The relation of memory depth sample rate and waveform length fulfills the equation below Memory depth sample rate Sa s x waveform length s div x div Thus in the same time base the higher memory depth can ensure a higher sample rate Press gt Mem Depth use amp 2 to switch to the desired memory depth the default is auto and then press down the knob to select the option You can also press Mem Depth continuously to switch the memory depth When a single channel is enabled the memory depths available include Auto 12kPoints 120kPoints 1200kPoints 12MPoints In Auto mode the oscilloscope selects the
128. le of the operation results 6 2 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL Substraction Subtract the waveform voltage values of signal source B from that of source A point by point and display the results Press MATH gt Math gt Operator to select A B Press Display to turn on or off the subtraction operation function Press Source Aand Source B to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use 42 to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results Multiplication Multiply the waveform voltage values of signal sour
129. lign their phase Use the oscilloscope to sample and display the waveforms of the two channels and you will see that the phase of the two waveforms shown on the oscilloscope changed At this point press AlignPhase and the waveforms on the oscilloscope will restore the current phase deviation of the two channels Modulation Press Modulation to turn the modulation function on or off For detailed information about modulation function please refer to Modulation To set impedance Press Impedance to set the output impedance of the current signal HighZ and 500 can be selected DS1000Z User s Guide 12 3 RIGOL Chapter 12 Signal Source To Output Square Waveform Press Src1 Setup to enter the waveform setting interface Press Wave to select Square at this point you can set relative parameter of the sine signal For the specified setting method please refer to the instruction of To Output Sine Waveform To Output Ramp Waveform Press Src1 Setup to enter the waveform setting interface Press Wave to select Ramp at this point you can set relative parameter of the sine signal For the specified setting method please refer to the instruction of To Output Sine Waveform symmetry is introduced only in this chapter Symmetry Symmetry is difined as the percentage that the rising period of ramp waveform takes up in the whole period t k Symmetry t T 100 To set the symmetry Press Symmetry and use to
130. llation options E Y O Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed ch removable media floppy CD ROM Include this location in the search 3 NIINLANE OM C Don t search will choose the driver to install 3 Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware Ce fne Found New Hardware Wizard Select the device driver you want to install for this hardware Pme Y Select the manufacturer and model of your hardware device and then click Next If you mee have a disk that contains the driver you want to install click Have Disk Show compatible hardware Model E USB Test and Measurement Device 5 A This driver is not digitally signed Tell me why driver signing is important 6 lt Back Cancel RIGOL DS1000Z User s Guide 15 3 RIGOL Chapter 15 Remote Control Found New Hardware Wizard Please wait while the wizhrd installs the software e USB Test and Measurement Device B p Hardware Update Wizard Completing the Hardware Update Wizard The wizard has finished installing the software for Q USB Test and Measurement Device Click Finish to close the wizard 7 3 Search device resource Start up the Ultr
131. ls with specified amplitude 1 Output Press Output to turn the signal output on or off 2 To set amplitude Press Amplitude to set the amplitude of the current signal and the range available is from 20 mVpp to 5Vpp when the impedance is HighZ or from 10 mVpp to 2 5 Vpp when the impedance is 50 Q For setting method please refer to the instruction of To set amplitude 3 To set the DC offset voltage Press Offset to set the DC offset of the current signal and the range available is from 2 5 V the amplitude value currently set 2 when the impedance is HighZ to 2 5 V the amplitude value currently set 2 when the impedance is 50 Q For setting method please refer to the instruction of To set the DC offset voltage Note that the offset value is only remained three significant figures For example when the amplitude is set to 10 mV the impedance is 50 Q the offset range calculated is 1 245 V to 1 245 V but the actual offset range is 1 24 V to 1 24 V DS1000Z User s Guide Chapter 12 Signal Source RIGOL To Output Built In Waveform 7 kinds of built in waveforms are provided by signal source builted in the DS2000A series odcilloscope including Sinc Exp Rise Exp Fall ECG Guass Lorentz Haversine Sinc The figure below shows a Sinc waveform Exponential Rise The figure below shows an Exponential Rise waveform Exponential Rise The figure below shows an Exponential Rise wavefo
132. lso be used to adjust the horizontal position and scale of the operation results Tip Because differentiation is very sensitive to noise so you can set the_Acquisition Mode to Average Square Root Calculate the square root of specified signal source point by point and display the results Press MATH gt Math gt Operator to select sqrt Press Display to turn on or off the square root operation function Press Source to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use 2 to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results 6
133. ly press Byte Length to set the length of the data and the range is from 1 to 5 press CurrentBit to select the desired data bit and the range is from 0 to Byte Length x8 1 press Data to set the data pattern of the current data bit to X H or L press AllBits to set the data pattern of all the data bits to the data pattern specified in Data press Direction to select Read Write or R W note when AddrBits is set to 8 bit this setting is not available Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on DS1000Z User s Guide 5 37 RIGOL Chapter 5 To Trigger the Oscilloscope Trigger Setting Press Setting to set the trigger parameter noise rejection under this trigger type Trigger Level Use TRIGGER LEVEL to modify the trigger level of SCL or SDA channel For details please refer to the description of Trigger Level on page 5 9 5 38 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL SPI Trigger Option Trigger on the data pattern on the specified edge When using SPI trigger you need to specify the SCL and SDA data sources Below is the sequence chart of SPI bus data transmission Processor 1 SPI Host 1 i i
134. measured 9 Overshoot the ratio of the difference of the maximum value and top value of 6 22 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL the waveform to the amplitude value 10 Preshoot the ratio of the difference of the minimum value and base value of the waveform to the amplitude value Other Parameters 1 AA Area the area of the whole waveform within the screen and the unit is voltage second The area meadured above the zero reference namely the vertical offset is positive and the area measured below the zero reference is negative The area measured is the algebraic sum of the area of the whole waveform within the screen 2 AA Period Area the area of the first period of waveform on the screen and the unit is voltage second The area above the zero reference namely the vertical offset is positive and the area below the zero reference is negative The area measured is the algeraic sum of the area of the whole period waveform Note that when the waveform on the screen is less than a period the period area measured is 0 DS1000Z User s Guide 6 23 RIGOL Chapter 6 To Make Measurements Frequency Counter Measurement The hardware frequency counter supplied with this oscilloscope can make more precise measurement of the input signal frequency Press Measure gt Counter to select CH1 CH4 as the measurement source The measurement result is displayed at the upper right corner of the screen and you can
135. mp 2 to adjust the vertical position of the reference waveform and press Scale and use to adjust the vertical scale of the reference waveform To Save to Internal Memory Press Save to save the waveform screen region in the specified source to internal memory as reference waveform and display it on the screen Note that this operation only saves the reference waveform in the volatile memory and the waveform will be Cleared at power off To Set the Color DS1000Z series oscilloscope provides five colors gray green light blue magenta and orange to mark the reference waveforms of different channels in order to distinguish them Press Current and use amp 2 to select any of the reference channels Ref1 Ref10 enabled Then press Color to specify a different color for the reference waveform of that channel The corresponding icon at the left of the channel currently selected will be filled with the specified color for example BI To reset the REF waveform Press Reset and the reference waveform returns to the position where the source channel waveform is located when the Save operation was executed DS1000Z User s Guide 8 3 RIGOL Chapter 8 Reference Waveform To Export to I nternal or External Memory Users can also save the reference waveform to the internal Flash memory or external USB storage device The file format of the reference waveform is ref At most 10 reference files LocalREFO ref to LocalREF9 ref can
136. n AT of this pattern meets the preset time as shown in the figure below LAT LAT CHI H CH2 L an d CH2 Trigger Type Press Type to select Duration At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 as the channel source of H L or X The current signal source is displayed at the upper right corner of the screen Pattern Setting Press Code to set the pattern of the current channel At this point the pattern setting area as shown in the figure below is displayed at the bottom of the screen Dur CHI HHH CH4 e a set the pattern of the channel selected to H namely the voltage level is higher than the threshold level of the channel e B set the pattern of the channel selected to L namely the voltage level is lower than the threshold level of the channel e E set the pattern of the channel selected to Don t Care namely this channel is not used as a part of the pattern When both the channels in the pattern are set to Don t Care the oscilloscope will not trigger DS1000Z User s Guide 5 19 RIGOL Chapter 5 To Trigger the Oscilloscope Trigger Condition Press When to select the desired trigger condition gt trigger when the duration of the pattern is greater than the preset time Press Time to set the duration of dur
137. ncy 75 kHz Rejection Trigger 1 0div below 5mV or noise rejection is enabled Sensitivity 0 3div above 5mV and noise rejection is disabled Edge Trigger Edge Type Rising Falling Rising amp Falling Pulse Trigger Pulse Condition Positive Pulse Width greater than lower than within specified interval Negative Pulse Width greater than lower than within specified interval Pulse Width Range 8nsto 10s Runt Trigger Pulse Condition None gt greater than lower than lt gt within the specified interval Polarity Positive Negative Pulse Width Range 8ns to 4s Windows Trigger Windows Type Trigger Position Rising Falling Rising amp Falling Enter Exit Time Windows Time 8 ns to 10s Nth Edge Trigger Edge Type Rising Falling DS1000Z User s Guide RIGOL Chapter 17 Specifications Idle Time 16 ns to 10 s Number of Edges 1 to 65535 Slope Trigger Slope Condition Positive Slope greater than lower than within specified interval Negative Slope greater than lower than within specified interval Time Setting 8 nsto 10s Video Trigger Signal Standard Support standard NTSC PAL and SECAM broadcasting standards Support 480P 576P HDTV standards Pattern Trigger Pattern Setting H L X Rising Edge Falling Edge Delay Trigger Edge Type Rising Falling Delay Type gt greate
138. ne Rotate 42 directly to set the desired implitude value Method two Press 4 to input desired paramrter values and unist directly using the pop up numeric keyboard To set the DC offset voltage Press Offset to set the DC offset of the current signal and the range available is from 2 5 V the amplitude value currently set 2 if the impedance is HighZ to 2 5 V the amplitude value currently set 2 if the impedance is 50 Q Rotate amp 2 directly to set the desired DC offset value DS1000Z User s Guide 5 Chapter 12 Signal Source RIGOL Method two Press 42 to input desired paramrter values and unist directly using the pop up numeric keyboard Note that the offset value is only remained three significant figures For example when the amplitude is set to 10 mV the impedance is 50Q the offset range calculated is 1 245 V to 1 245 V but the actual offset range is 1 24 V to 1 24 V To set the start phase Press Start Phase to set the start phase of the current signal and the range available is from 0 to 360 Method one Rotate directly to set the desired start phase Method two Press 2 to input desired paramrter values and unist directly using the pop up numeric keyboard Align phase Press AlignPhase to re configration the two channels and enable the signal source to output with specified frequency and phase For two signals whose frequencies are the same or in multiple this operation will a
139. nnel is greater than the threshold of the corresponding channel it is regarded as logic 1 otherwise logic 0 The following common logic operation expressions are provided The results of logic NOT operation of a binary bit are as follows A IA 0 1 1 Press gt Math gt Operator to select A Press Display to turn on or off the NOT operation function Press Source Aand Source B to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use 42 to adjust the vertical offset of the operation result Press Scale and use amp 2 to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Tre A and use to set the threshold of source A in logic operation Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Sens to set the sencitivity of the operation results and the range available is 0 div to 0 96 div Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration a
140. nt results the units of AY BY and BY AY will be automatically set to the unit of the current source Persent when this unit is selected in the measurement results AY BY and DS1000Z User s Guide 6 31 RIGOL Chapter 6 To Make Measurements BY AY are in 96 At this point AY BY and BY AY will change to 0 100 and 10096 when you press Set Range no matter where cursor A and B are currently located At the same time two cursor lines unmovable appear on the screen as the reference positions 5 Measurement Example Use manual cursor measurement to measure the period BX AX of a square waveform and the result is 1 ms equaling the result from auto measurement Cursor Measurement Source Auto 6 32 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL Track Mode In this mode one or two pairs of cursors will appear You can adjust the two pairs of cursors cursor A and cursor B to measure the X and Y values on two different sources respectively The points being measured on cursor A and B are marked by and respectively When the cursors are moved horizontally the marks will position on the waveform automatically When the waveform is expanded or compressed horizontally the marks will track the points being marked at the last adjustment of the cursors Press Cursor gt Mode gt Track to turn on the cursor track function and the measurement results will be displayed at the upper l
141. nthe background grid and coordinate off To Set the Grid Brightness Press Display gt Brightness to set the brightness of the screen grid Turn amp 2 to adjust the grid brightness The default is 5096 and the range available is from 096 to 100 To Set the Menu Display Press Display gt Menu Display to set the menu display time The menu will hold for a specified period of time after the last button pressing action and then is hidden The display time can be set to 1 s 2 s 5 s 10s 20 sor Infinite the menu will not be hidden DS1000Z User s Guide 11 5 Chapter 12 Signal Source RIGOL Chapter 12 Signal Source It is particularly suitable for the test application of excitation response with the dual channel 25 MHz signal source built in the oscilloscope and it is very convenient for the engineers who need both signal source and oscilloscope to combine the signal source with the oscilloscope This chapter will introduce how to use the signal source builted in the oscilloscope As the function and the setting method of the two channels of the signal are the same this chanpter only takes sourcel setting for illustration Press menu key to enter the signal setting interface Press Output to turn the signal output on or off After ON is selected the instrument will output the signal currently set from the Source1 connector at the rear panel Note you also can turn on the signal output by the Output under the Src
142. o press 2 continuously to switch the current cursor Adjust cursor A press CursorA and use to adjust the position of cursor A During the adjustment the measurement result will change accordingly The adjustable range is limited within the screen Adjust cursor B press CursorB and use to adjust the position of cursor B During the adjustment the measurement result will change accordingly The adjustable range is limited within the screen Adjust cursor A and B at the same time press CursorAB and use to adjust the position of cursor A and B at the same time During the adjustment the measurement results will change accordingly The adjustable range is limited within the screen Note the vertical cursor will track the marked point namely jumps up and down with the transient change of the waveform Thus the Y value might change even though you do not adjust the cursor DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL Auto Mode In this mode one or more cursors will appear You can use auto cursor measurement to measure any of the 24 waveform parameters Before using this mode you need to at least enable one auto measurement parameter and the number of cursors will change with the measurement parameter enabled Press Cursor Mode gt Auto and the number of cursors displayed on the screen is determined by the measurement parameter enabled different measurement parameter needs different n
143. odify the level For details please refer to the description of Trigger Level on page 5 9 DS1000Z User s Guide 5 33 RIGOL Chapter 5 To Trigger the Oscilloscope RS232 Trigger Option Trigger according to the start frame error frame check error or data Below is the explanatory figure of RS232 protocol N ibit 8bits gt lt abt gt ibit Start Bit Data Bit Check Bit Stop Bit Trigger Type Press Type to select RS232 At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 as the Trigger Source The current trigger source is displayed at the upper right corner of the screen Polarity Press Polarity to select the polarity of date transmission It can be set to Normal or Invert and the default is normal Trigger Condition Press When to select the desired trigger condition Start trigger on the start frame position Error trigger when error frame is detected After this trigger condition is selected press Stop Bit to select 1 bit or 2 bit press Even OddCheck to select None Odd Checkout or Even Checkout The oscilloscope will determine error frame according to the preset parameters Check Error trigger when check error is detected When this trigger condition is selected press Even OddCheck to select Odd Checkout or Even Checkout The oscilloscope will
144. oint CS is invalid not displayed Data Line Setting Set the instrument to trigger when the specified bit and length of data is transmitted in the SDA Press Data Bits to set the number of bits of the serial data character string It can be set to any integer between 4 and 32 Press CurrentBit to set the number of the data bit and the range is from 0 to value sepecified in Data Bits 1 Press Data to set the value of the current bit to H L or X Press AllBits to set all the data bits to the value specified in Data Clock Edge Press Clock Edge to select the desired clock edge e EJ sample the SDA data on the rising edge of the clock e ba sample the SDA data on the falling edge of the clock Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameter noise rejection under this trigger type Trigger Level Use TRIGGER LEVEL to modify the level For details please refer to the description of Trigger Level on page 5 9 5 40 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Trigger Output Connector The trigger output connector at the rear panel can output trigger signals determined by the current setting
145. oll Mode In this mode the waveform scrolls from the right to the left to update the display and the waveform horizontal position and trigger control are not available The range of horizontal scale adjustment is from 200 0 ms to 1 000 ks Note when Roll mode is enabled Delayed Sweep and 5 To Trigger the Oscilloscope are not available Slow Sweep Another mode similar to Roll mode When the horizontal time base is set to 200 ms div or slower the instrument enters slow sweep mode in which the instrument first acquires the data at the left of the trigger point and then waits for trigger event After the trigger occurs the instrument continues to finish the waveform at the right of the trigger point When slow sweep mode is used to observe low frequency signal it is recommended that the Channel Coupling is set to DC 3 8 DS1000Z User s Guide Chapter 4 To Set the Sample System RIGOL Chapter 4 To Set the Sample System The contents of this chapter B Acquisition Mode BH Sample Rate m Memory Depth DS1000Z User s Guide 4 1 RIGOL Chapter 4 To Set the Sample System Acquisition Mode The acquisition mode is used to control how to generate waveform points from sample points Press Acquire gt Mode in the function menu at the front panel and use to select the desired acquisition mode the default is normal then press down the knob to select this mode You can also press Mode continuously to
146. on and if the display is turned on another label SIS will be set for the channel DS1000Z User s Guide 2 7 Chapter 3 To Set the Horizontal System RIGOL Chapter 3 To Set the Horizontal System The contents of this chapter B Delayed Sweep B Time Base Mode DS1000Z User s Guide 3 1 RIGOL Chapter 3 To Set the Horizontal System Delayed Sweep Delayed sweep can be used to enlarge a length of waveform horizontally to view the waveform details Press IMENU in the horizontal control area HORIZONTAL at the front panel and press Delayed to enable or disable delayed sweep Note that to enable delayed sweep the current time base mode must be YT 3 2 DS1000Z User s Guide Chapter 3 To Set the Horizontal System RIGOL In delayed sweep mode the screen is divided into two display areas as shown in the figure below The waveform before enlargement Main time H 200us WAVAVAVAVAVAWAVATA DU 000000000 base Horizontal Delayed YT Sweep Zoom 100 0us Time Base Mi The waveform after enlargement The waveform before enlargement The waveform in the area that has not been covered by the subtransparent blue in the upper part of the screen is the waveform before enlargement You can turn HORI ZONTAL gt POSITI ON to move the area left and right or turn HORI ZONTAL SCALE to enlarge or reduce this area The waveform after enlargement The waveform in the lower part of the screen is the
147. on memory As shown in the figure below the position of the trigger event is determined by the reference time point and the delay setting Note that the acquisition memory of the oscilloscope is a cyclic buffer and the new data would overwrite the old data until the acquisition finishes Trigger Event Pre trigger Buffer Post trigger Buffer Acquisition memory Pre trigger Delayed trigger Acquire data before after the trigger event The trigger position is usually at the horizontal center of the screen In full screen display six grid pre trigger and delayed trigger information are displayed respectively You can adjust the horizontal position of the waveform through HORI ZONTAL POSITI ON to view more pre trigger information and delayed trigger information through which the signal information before after the trigger such as capture the glitch generated by the circuit and analyze the pre trigger data to find out the reasons for glitch can be obtained Press in the trigger control area TRI GGER at the front panel or press IMENU gt Sweep to select the desired trigger mode The corresponding status light of the mode currently selected turns on Auto No matter whether the trigger condition is met there is always waveform display A horizontal line is displayed when no signal is input In this mode the oscilloscope operates by first filling the pre trigger buffer It starts searching for a trigger after the pre trigger buffer
148. onnected to the low voltage installation Examples are measurements on household appliances portable tools and similar equipment Measurement category Ill is for measurements performed in the building installation Examples are measurements on distribution boards circuit breakers wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and equipment for industrial use and some other equipment for example Stationary motors with permanent connection to the fixed installation Measurement category IV is for measurements performed at the source of the low voltage installation Examples are electricity meters and measurements on primary overcurrent protection devices and ripple control units DS1000Z User s Guide V RIGOL Ventilation Requirement This oscilloscope uses fan to force cooling Please make sure that the air intake and exhaust areas are free from obstructions and have free air When using the oscilloscope in a bench top or rack setting provide at least 10 cm clearance beside above and behind the instrument for adequate ventilation WARNING AN Inadequate ventilation may cause temperature increase which would damage the instrument So please keep the instrument well ventilated during operation and inspect the intake and fan regularly VI DS1000Z User s Guide RIGOL Working Environment Temperature Operating 0 C to 50 C Non operating 40 C to 70 C Humidit
149. ons of A B C and D are as shown in the figure above the phase deviation angle is obtained that is 0 zcarcsin A B or tarcsin C D If the principal axis of the ellipse is within quadrant and III the phase deviation angle obtained should be within quadrant and IV namely within 0 to 11 2 or 3117 2 to 211 If the principal axis of the ellipse is within quadrant II and IV the phase deviation angle obtained should be within quadrant Il and III namely within 1 2 to TI or rr to 377 2 XY function can be used to measure the phase deviation occurred when the signal under test passes through a circuit network Connect the oscilloscope to the circuit to monitor the input and output signals of the circuit DS1000Z User s Guide 3 5 RIGOL Chapter 3 To Set the Horizontal System Application example measure the phase deviation of the input signals of two channels Method 1 Use Lissajous method 1 Connect a sine signal to CH1 and then connect a sine signal with the same frequency and amplitude but a 90 phase deviation to CH2 2 Press AUTO and adjust the vertical position of CH1 and CH2 to 0 3 Press X Y to select CH1 CH2 rotate Horizontal SCALE to ajdut the sample rate properly to get better Lissajous figure for better observation and measurement 4 Roate VERTICAL POSITION to adjust CH1 and CH2 to get better observation of signals At this point the circle as shown in the figure below should b
150. orms in two channels Note that when the voltage value of channel B is 0 the result of the division is treated as 0 Press gt Math gt Operator to select A B Press Display to turn on or off the division operation function Press Source Aand Source B to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use amp 2 to adjust the vertical offset of the operation result e Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is 6 4 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results DS1000Z User s Guide 6 5 RIGOL Chapter 6 To Make Measurements FFT FFT is used to quickly perform Fourier tran
151. oscope to Min specific values 100 ms 200 ms 500 ms 1 s 25 5 s 10 s and 20 s or Infinite In the following part a frequency sweep signal of the sine waveform is used to demonstrate the waveform effects in different persistence times 1 Min Enable to view waveform changing in high refresh rate 2 Specific Values Enable to observe glitch that changes relatively slowly or glitch with low occurrence probability The persistence time can be set to 50 ms 100 ms 200 ms 500 ms 1s 25 5 s 10 s or 20 s 3 Infinite In this mode the oscilloscope displays the waveform newly acquired without clearing the waveforms acquired formerly The waveforms acquired formerly will be displayed in relatively low brightness color and the waveform newly acquired DS1000Z User s Guide 11 3 RIGOL Chapter 11 Display Control will be displayed in normal brightness and color Infinite persistence can be used to measure noise and jitter and to capture incidental events 11 4 DS1000Z User s Guide Chapter 11 Display Control RIGOL To Set the Waveform I ntensity Press Display gt Wavel ntensity or turn 2 when the menu is hidden to adjust the waveform brightness of the analog channel The default is 5096 and the range available is from 096 to 10096 To Set the Screen Grid Press Display gt Grid to set the screen grid type e EH turn the background grid and coordinate on e HH turn the background grid off e Lltur
152. otate amp 2 directly to set the desired voltage value Method two Press 42 to input desired paramrter values and unist directly using the pop up numeric keyboard DS1000Z User s Guide 12 17 RIGOL Chapter 12 Signal Source 5 Time Press Time to set the duration time of the current point and this setting is limited by the duration times of the previous point and the next point The point 1 is fixed at 0 s 6 Insert point Press Insert to insert a new point at the middle position of the current edited point and the next edited point 7 Delete point Press Delete to delete the current point from waveform and connect the remaining points using the currtnt interpolation method Note that point 1 can not be deleted 8 Apply Press Apply to apply the waveform currently edited 9 Save Press Save to enter the files store interface Please refer to the instruction of 13 Store and Recall to save the waveform files currently created in the internal or external memory in arb format The internal memory of the instrument can store 10 arbitrary waveforms LocalArb arb If the current position exist a file the original file will be overwriten You can output the arbitrary waveforms saved in the internal or external memory and for the specified operation please refer to the instruction of To Select Waveform 12 18 DS1000Z User s Guide Chapter 12 Signal Source RIGOL Modulation The signal source builted in the DS2
153. pe for Use To Adjust the Supporting Legs Adjust the supporting legs properly to use them as stands to tilt the oscilloscope upwards for stable placement of the oscilloscope as well as better operation and observation LEER 7 LUAM Figure 0 3 To Adjust the Supporting Legs 1 4 DS1000Z User s Guide Chapter 1 Quick Start RIGOL To Connect to Power Supply The power requirements of DS1000Z are 100 240 V 45 440 Hz Please use the power cord supplied with the accessories to connect the oscilloscope to the power source Power Socket Figure 0 4 To Connect to Power Source DS1000Z User s Guide 1 5 RIGOL Chapter 1 Quick Start Power on I nspection When the oscilloscope is energized press the power key at the lower left corner of the front panel to start the oscilloscope During the start up process the oscilloscope performs a series of self tests and after the self test is finished the welcome screen is displayed and you can view the Option Type Option name Option Edition and Left time of the option currently installed in the Installed Options pop up dialog box on the screen When the instrument is shipped a trial version of the option is provided and the left time is about 2000 minutes
154. perator in the vertical control area VERTICAL at the front panel to select the desired operator The result of math operation will be displayed on the waveform marked with M on the screen after the operation was enabled Addition Add the waveform voltage values of signal source A and B point by point and display the results Press gt Math gt Operator to select A B Press Display to turn on or off the addition operation function Press Source Aand Source B to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use 42 to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and sca
155. play function on or off When it is turned on the current format display of the bus will be displayed on the right of the label display when the bus display is turned on and you can use Format to set the display format of the bus Press Endian to turn the endian display function on or off When it is turned on the current endian display will be displayed on the right of the format display when the bus display is turned on and you can use Endian to set the bus endian Press Width to turn the width display function on or off When it s turned on the data width of each frame will be displayed on the right of the endian display when the bus display is turned on and you can use Data softkey to set the data width of each frame Press DataSrc to select Trace or Memory as the data source Press Range to select Full or User When Full is selected the instrument will determine the decoding range according to the current selection of the current data source when User is selected press Start to set the start point of the decoding and the range available is from 0 to end point 1 and press End to set the end point of the decoding and the range available is from start point 1 to 1199 7 8 DS1000Z User s Guide Chapter 7 Protocol Decoding RIGOL 10 The Error Expression during Decoding End Frame Error Errors generated when the end frame condition is not met When the stop bit is set to 1 error mark will be
156. ple create a file or folder with the name Filename 1 Press Keyboard 1 Use to select English input method En and uppercase input state A 2 Use 2 to input the letter F If the input is wrong press Delete to delete the character input 3 Use to select lowercase input state Aa 4 Use to input the remaining letters ilename Name Input Area Keyboard Upper lower Case Switch Input Method Switch 2 During the name input you can press Name to select the Name Input Area and use amp 2 to move the cursor then press Delete to delete the characters on the left of the cursor one by one 3 After finishing the input press OK and the oscilloscope will create a folder or a specified type of file with this name under the current directory 13 10 DS1000Z User s Guide Chapter 13 Store and Recall RIGOL Chinese I nput Method For example create a file or folder with the name cf 1 Press Keyboard 1 Use 42 to select Chinese input method Note that Chinese is added in the menu items at the right of the screen 2 Use to input the pinyin wen If the input is wrong press Delete to delete the pinyin input After wen is input a series of Chinese characters appear in the Chinese Chraracter Selecting Area 3 Press Chinese and use 42 to select and input X 4 Use the same method to input fF and 4 Pinyin Input Area Chinese Character Selecting Area Input Method Switch
157. quence This format is only valid for the serial bus because the serial bus has the difference of bit sequence of LSB and MSB if bit sequence of the bus is selected MSB the LINE format is the same to the binary format Press Pos and use to adjust the vertical display position of the bus 6 Decoding Configuration Press Decoding1 Configure to turn the decoding configuration submenu on Press Label to turn the label display function on or off When it is turned on the bus label will be displayed at the upper left of the bus when the bus 7 12 DS1000Z User s Guide Chapter 7 Protocol Decoding RIGOL display is turned on Press Line to turn the bus display function on or off When it is turned on the bus display will be displayed on the screen and you can use Pos to adjust the vertical display position of the bus Press Format to turn the format display function on or off When it is turned on the current format display of the bus will be displayed on the right of the label display when the bus display is turned on and you can use Format to set the display format of the bus Press Endian to turn the endian display function on or off When it is turned on the current endian display will be displayed on the right of the format display when the bus display is turned on and the default is MSB Press Width to turn the width display function on or off When it s turned on the data width of each frame will be displaye
158. r than lower than lt gt within the specified interval gt lt outside the specified interval Delay Time 8nsto 10s TimeOut Trigger Edge Type Rising Falling Rising amp Falling TimeOut Value 16 ns to 10 s Duration Trigger Pattern Setting H L X Trigger Condition gt greater than lt lower than lt gt within the specified interval Duration Time 8 nsto 10s Setup Hold Trigger Edge Type Rising Falling Data Pattern H L X Setup Time 8nstols Hold Time 8nstols RS232 UART Trigger Polarity Normal Invert Trigger Condition Start Error Check Error Data Baud 2400 bps 4800 bps 9600 bps 19200 bps 38400 bps 57600 17 4 DS1000Z User s Guide Chapter 17 Specifications RIGOL bps 115200 bps User Data Bits 5 bits 6 bits 7 bits 8 bits 12C Trigger Trigger Condition Start Restart Stop Missing Ack Address Data A amp D Address Bits 7 bits 8 bits 10 bits Address Range 0x0 to Ox7F 0x0 to OxFF 0x0 to Ox3FF Byte Length 1to5 SPI Trigger Trigger Condition TimeOut CS Timeout Value 16 ns to 10 s Data Bits 4 bit to 32 bit Data Line Setting H L X Measure Cursor Voltage deviation between cursors AV Manual is riade Time deviation between cursors AT Reciprocal of AT Hz 1 AT Track mode Voltage and time values of the waveform point Auto mode Allow to display cursors during auto measurement Auto Measurement Measurements of
159. r those problems please solve them following the corresponding steps If the problem remains still please contact RIGOL and provide your device information Utility gt System gt System Info 1 3 4 The screen is still dark no display after power on 1 Check if the power is correctly connected 2 Check whether the fuse is burned out If the fuse needs to be changed please use the specified fuse 3 Restart the instrument after finishing the above inspections 4 If it still does not work correctly please contact RIGOL The signal is sampled but no waveform of the signal is displayed 1 Check if the probe is correctly connected to the oscilloscope and the item under tested 2 Check if there are signals generated from the item under test you can connect the probe compensation signal to the problematic channel to determine which has problems the channel or the item under test 3 Resample the signal The voltage amplitude measured is greater or lower than the actual value note that this failure usually only occurs when probe is used Check whether the attenuation coefficient of the channel complies with the attenuation ratio of the probe There is waveform display but not stable 1 Check the trigger signal source check whether the Source item at the trigger panel complies with the signal channel actually used 2 Check the trigger type general signals should use Edge trigger and video
160. ramrter values and unist directly using the pop up numeric keyboard 6 Align phase Press AlignPhase to re configration the two channels and enable the signal source to output with specified frequency and phase For two signals whose frequencies are the same or in multiple this operation will align their phase Use the oscilloscope to sample and display the waveforms of the two channels and you will see that the phase of the two waveforms shown on the oscilloscope changed At this point press AlignPhase and the waveforms on the oscilloscope will restore the current phase deviation of the two channels 7 Select waveform Select the srbitrary waveform stored in the internal or external memories For detailed information please refer to To Select Waveform 8 Create waveforms Users can create defined waveform For detailed information please refer to To Create Waveform 9 Edit waveform Edit the arbitrary waveforms already stored For detailed information please refer to To Edit Waveforms DS1000Z User s Guide 12 13 RIGOL Chapter 12 Signal Source 10 Modulation Press Modulation to turn the modulation function on or off For detailed information about modulation function please refer to Modulation 11 To set impedance Press Impedance to set the output impedance of the current signal HighZ and 500 can be selected The following will introduce how to To Select Waveform To Create Waveform
161. rates 6 28 ASO cilii RT 6 29 Manual ModE RTT e 6 30 ji o4 n f 6 33 loj 6 35 Chapter 7 7 Protocol Decoding eeeeeeeeeeee eene 7 1 Paralel DECO osi zu oiv doit d lbi EHE da Ea REX ER oh 7 2 R5222 Decoding CONQBID osaribeibotvPbba HU NEP RI ERE RbrREPREP d Lb UU REIR DEN DE DEOR 7 5 2C Decoding Opto occa npkavdst on Ext DERE RADI R APA EE RAN OXR dO CK MEAE 7 11 SPI Decoding FINS eT 7 15 Chapter 8 8 Reference Waveform eeeeneee eee eene 8 1 TO Enable REF FUNCOM crara saninin rbd rx Exodi si kel Roe ui p hir rb 8 2 Tele REF SEE m Dem 8 2 To Adjust REF Waveform Display iiie eie casio et DO n d ee ac e Hadad 8 3 To Save to Internal TG yw ase cece sessed OR EAE MEE Do OR HR BED 8 3 Te Sel ne Cal a 8 3 To reset the REF wavefor M iiie ccssjaascorsvitueceidees cssastea EE OR ERE FECE ET ORAE 8 3 To Export to Internal or External Memory seseeennm m 8 4 To Import from Internal or External Memory seene 8 4 Chapter 9 9 Pass Fail Tasks iiiaiiadonkakel Road on e o Rl 9 1 gs 32 d lo xc 9 2 TO dcos pe RUPES 9 2 EAR BOUE oi rb ibn HP URS wed mU MM pL D PAPE NIB 9 2 BF neBrigem T mabe E meee 9 3 IR oH 4 Am 9 4 ILES MI io NOTET 9 4 Chapter 10 10 Waveform Record 1eeererneee 10 1 Payback SOL astern ot ec is cin
162. re re arming the trigger circuitry The oscilloscope will not trigger until the holdoff time expires Press MENU gt Setting gt Holdoff in the trigger control area TRIGGER at the front panel and use to modify the holdoff time the default is 16 ns until the waveform triggers stably The adjustable range of holdoff time is from 16 ns to 10 s Note that trigger holdoff is not available for video trigger 5 6 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Noise Rejection Noise Rejection adds additional trigger sensitivity Noise rejection reduces the possibility of noise trigger but also reduces the trigger sensitivity therefore a larger signal is required to trigger the oscilloscope Press MENU gt Setting gt Noise Reject in the trigger control area TRIGGER at the front panel to enable or disable noise rejection DS1000Z User s Guide 5 7 RIGOL Chapter 5 To Trigger the Oscilloscope Trigger Type DS1000Z provides various trigger functions including various serial bus triggers Edge Trigger Pulse Trigger Slope Trigger Video Trigger Pattern Trigger Duration Trigger Setup Hold Trigger TimeOut Trigger Option Runt Trigger Option Windows Trigger Option Delay Trigger Option Nth Edge Trigger Option RS232 Trigger Option 12C Trigger Option SPI Trigger Option 5 8 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Edge Trig
163. red paramrter values and unist directly using the pop up numeric keyboard To set amplitude Press Amplitude to set the amplitude of the current signal and the range available is from 20 mVpp to 5Vpp when the impedance is HighZ or from 10 mVpp to 2 5 Vpp when the impedance is 50 Q Method one Rotate 42 directly to set the desired implitude value Method two Press 42 to input desired paramrter values and unist directly using the pop up numeric keyboard To set the DC offset voltage Press Offset to set the DC offset of the current signal and the range available is from 2 5 V the amplitude value currently set 2 when the impedance is HighZ to 2 5 V the amplitude value currently set 2 when the impedance is 50 Q Rotate 4 directly to set the desired DC offset value 12 12 DS1000Z User s Guide Chapter 12 Signal Source RIGOL Method two Press to input desired paramrter values and unist directly using the pop up numeric keyboard The offset value is only remained three significant figures For example when the amplitude is set to 10 mV the impedance is 50 Q the offset range calculated is 1 245 V to 1 245 V but the actual offset range is 1 24 V to 1 24 V 5 To set the start phase Press Start Phase to set the start phase of the current signal and the range available is from 0 to 360 Method one Rotate 2 directly to set the desired start phase Method two Press 2 to input desired pa
164. rement items enabled 6 26 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL All Measurement All measurement could measure all the time and voltage parameters each measurement source has 20 items measurements can be performed on CH1 CH2 CH3 and CH4 at the same time of the current measurement source and display the results on the screen Press Measure gt Measure All to enable or disable the all measurement function Press All Measure Source and use to select the channel s to be measured CH1 CH4 When all measurement is enabled One key measurement is also valid e To Clear the Measurement will not clear the results of all measurement Counter Freq Rise Fall id Wid Duty Duty Area AreaP OFF All Measurement Clear Measure All ON One key Measurement DS1000Z User s Guide 6 27 RIGOL Chapter 6 To Make Measurements Statistic Function Make statistic and display the current average minimum or standard deviation and maximum or count values of at most 5 measurement items that are turned on last Press Measure gt Statistic to turn the statistic function on or off When the statistic function is enabled press Stat Sel to select Extremum or Difference measurement When Extremum is selected minimum and maximum values are displayed When Difference is selected standard deviation and count values are displayed Extremum Measurement Difference Measurement Press gt
165. rigger Position After selecting the windows type press Position to further specify the time point of trigger by selecting the trigger position Enter trigger when the trigger signal enters the specified trigger level range Exit trigger when the input signal exits the specified trigger level range Time used to specify the hold time of the input signal after entering the specified trigger level range The instrument triggers when the accumulated hold time equals the windows time 5 28 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL Vertical Window Press Vertical to select the desired vertical window type For detailed operation referto Vertical Window on page 5 26 Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameters trigger holdoff and noise rejection under this trigger type DS1000Z User s Guide 5 29 RIGOL Chapter 5 To Trigger the Oscilloscope Delay Trigger Option Trigger when the time difference AT between the specified edges of source A and source B meets the preset time limit as shown in the figure below Note that edge A and edge B must be neighbouring edges Edge A Edge B AN Source A V Source B k A I Trigger Type Press Typ
166. rm T 02U n DS1000Z User s Guide RIGOL Chapter 12 Signal Source ECG The figure below shows an ECG waveform 26 24 18 iai osp Guass The figure below shows a Guass waveform i i 0 8 6 2 0 2 4 6 8 10 Lorentz The figure below shows a Lorentz waveform x 10 Lorentz 5 45 5 4 35 12 8 DS1000Z User s Guide Chapter 12 Signal Source RIGOL Haversine The figure below shows a Haversine waveform 1 Press Srcl Setup to enter the waveform setting interface Press Wave to select Built In at this point you can set relative parameter of the output signal according to the kinds of built in waveform selected 1 2 3 Output Press Output to turn the signal output on or off To select built in waveform Press Built In to select any one of the 7 kinds of built in waveforms To set frequency Press Frequency to set the frequency of the current signal and the range available is from 100 mHz to 1 MHz Method one Rotate 42 directly to set the desired frequency value Method two Press to input desired paramrter values and unist directly using the pop up numeric keyboard To set amplitude Press Amplitude to set the amplitude of the current signal and the range available is from 20 mVpp to 5Vpp when the impedance is HighZ or from 10 mVpp to 2 5 Vpp when the impedance is 50 Q Method one
167. rorameasaciosamaotiani ea na 1 8 Probe a UL adierit nce tu E epERE DR eer ERI a Ru dd cee 1 10 Front Patel DUGTVIBUC sce adr RD PEU Qd dae kl EK n AM nee EE 1 11 Rear Panel QUEEN Scc Ep inta x AER ED b A MEO m MM de RM FIR 1 12 Front Panel Function Overview xc visas tien d ensi ora Rak GER S FARA EHE A REY ubt dei tunes 1 14 pu gps E enero ey ener DR ETT 1 14 419 Fo ES MERNDHCNEP TR eT 1 15 TRIER asco Ure pM E DRE D DS UD nq ENDE 1 15 CLEAR P n 1 16 BINDS RUP Lex icu IM UE e MM MD M MED M IE 1 16 cd Pam PITT TEES 1 16 BUT bas DR MD E MEE MU MEM E 1 16 dit m TTE lc 1 17 XVI DS1000Z User s Guide USUS TED TT 1 18 User IMEG Idee ecce ux LR a Bonet E EUR RO RAD 1 19 DIU ihe Secun Ok E 1 23 To Use me Built in Help Systenti ius eon ide dee DO e eo HO Ra cbr D KE E 1 24 Chapter 2 2 To Set the Vertical System eere 2 1 To Enable the Crib Wal cox eracuetao cr e pRrE Prx EAR xD EXER RU A 2 2 Ernie COAG gece 2 3 Bet Ea TEETE AEI EIEEEI TEETE TR 2 3 Pole Rat eaan ET OUT Tre eerie etree 2 4 Weave Tar DOYE ua aci creta cer pi eX XO UNA RE E ER AM REX ERR d Ein ER d 2 5 bog bes mete e T a 2 5 varita EPIN O di an ax Ele FEDERE a EL UELR CERTE KOH e KO RD 2 6 BORGO DIU sco EIE rip bbre ir p PROP Er eRbA I Passo HM M REN 2 6 Channel Lab8l iioi ratur Gba prado porc BUR CHER ASI RESQUE IM Soe 2 7 Chapter3 3 To Set the Horizontal System eene 3 1 BIS E NUI ORE t OO eed 3 2 T
168. rtically Use VIRTICAL SCALE to modify this parameter The following labels will be displayed according to the current channel setting channel coupling e g Ell and bandwidth limit e g Bh 1 20 DS1000Z User s Guide Chapter 1 Quick Start RIGOL 13 CH2 Vertical Scale Display the voltage value per grid of CH2 waveform vertically Use VIRTICAL gt SCALE to modify this parameter e The following labels will be displayed according to the current channel setting channel coupling e g El and bandwidth limit e g Il 14 CH3 Vertical Scale Display the voltage value per grid of CH3 waveform vertically Use VIRTICAL SCALE to modify this parameter The following labels will be displayed according to the current channel setting channel coupling e g Bil and bandwidth limit e g Bl 15 CH4 Vertical Scale Display the voltage value per grid of CH4 waveform vertically Use VIRTICAL gt SCALE to modify this parameter The following labels will be displayed according to the current channel setting channel coupling e g and bandwidth limit e g Bl 16 Message Box Display prompt messages 17 Sourcel Waveform Display the type of waveform currently set for Sourcel e When the modulation is enabled E will be displayed at the bottom of the Sourcel Waveform When the impedance of signal source is set to 50 Q W will be displayed at the bottom of the Source1 Waveform e Only available
169. rval of playback The range availbale is from 100 ns to 10 s and the default is 100 ns 4 Start Frame Press Start and use amp 2 to set the start frame of playbak The default is 1 and the maximum is the maximum number of frames recorded 5 End Frame Press End and use 2 to set the end frame of the playback The default is the total number of frames of the waveform recorded 10 2 DS1000Z User s Guide Chapter 10 Waveform Record RIGOL Tip During waveform playback RUN STOP can be used to switch between playback and pause Each time SINGLE is pressed the Current Frame moves one frame forward Record Setting You can press Record Opt to set the following parameters before waveform record 1 Interval Press Interval to set the time interval between frames in waveform recording and the range available is from 100 ns to 10 s Record Length Press Length to set the number of frame currently recorded and the range available is from 1 to the maximum number of frames that can be recorded currently Press Set Max to set the number of frame to the maximum number of frames that can be recorded Maximum Number of Frames The menu shows the maximum number of frames that can be recorded currently As the capacity of the waveform memory is fixed the more the number of points each frame of waveform has the less the number of waveform frames can be recorded Thus the maximum end frame of waveform record is
170. s include the current system informations such as model firmware version and software version and so on and the current relative settings information such as vertical system horizontal system and normal trigger system DS1000Z User s Guide Chapter 13 Store and Recall RIGOL Internal Storage and Recall Internal storage and recall support Setups in Storage In the following part the storage and recall method and procedures are introduced 1 Save the specified oscilloscope setting in internal memory 1 Connect the signal to the oscilloscope and obtain stable display 2 Press Storage gt Storage to select Setups press Save and use 2 to select Local Disk appears as blue shading and press down amp 2 to open the local disk 3 Press New File to creat a file name using the pop up keyboard and for specific operations please refer to the instruction of To Create a New File or Folder f the internal memory has saved files in this type use 2 to select the file and Save and Delete areilluminated at this point press Save to execute the saving operation the original file can be overwritten or be delected by pressing Delete Use 42 to select ETE and then press down 2 to return to the previous directory 2 Loadthe specified type of file in internal memory 1 Press Storage to select Setups and then press Load and use 42 to select Local Disk and then press down amp 2 to open the local disk 2 If the internal
171. s knob to quickly switch to delayed sweep state TRIGGER MODE press this key to switch the trigger mode to Auto Normal Gelade Or Single and the corresponding state backlight of the current trigger mode would be illuminated TRIGGER LEVEL modify the trigger level Turn clockwise to increase the level and turn counterclockwise to reduce the level During the modification the trigger level line would move up and down and the value in the trigger level message box e g EERE at the lower left corner of the screen would change accordingly Press down the knob to quickly reset the trigger level to zero point DS1000Z User s Guide 1 15 RIGOL SINGLE Chapter 1 Quick Start MENU press this key to open the trigger operation menu This oscilloscope provides various trigger types FORCE press this key to generate a trigger signal forcefully Press this key to clear all the waveforms on the screen If the oscilloscope is in RUN state new waveforms will still be displayed Press this key to set the state of the oscilloscope to RUN or STOP In RUN state the key is illuminated in yellow In STOP state the key is illuminated in red Press this key to set the trigger mode to Single In single trigger mode press FORCE to generate a trigger signal immediately Press this key to enable the waveform auto setting function The oscilloscope will automatically adjust t
172. s regarded as logic 1 otherwise logic 0 The following common logic operation expressions are provided The results of logic AND operation of two binary bits are as follows A B A amp amp B 0 0 0 0 1 0 1 0 0 1 1 1 Press MATH gt Math gt Operator to select A amp amp B Press Display to turn on or off the AND operation function Press Source A and Source B to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Tre A and use 2 to set the threshold of source A in logic operation Press Tre B and use 2 to set the threshold of source B in logic operation Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Sens to set the sencitivity of the operation results and the range available is O div to 0 96 div Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the be
173. sform on specified signals and transform time domain signals to frequency domain signals FFT operation can facilitate the following works Measure harmonic components and distortion in the system Measure the characteristics of the noise in DC power Analyze vibration Press gt Math gt Operator to select FFT and set the parameters of FFT operation Frequency Domain Waveform Time Domain Waveform 1 Operation Press Display to enable or disable the FFT operation function 2 Select Source Press Source to select the desired channel CH1 CH2 CH3 or CH4 3 Vertical Offset Press Offset and use 2 to adjust the vertical offset of the operation result 6 6 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL 4 Vertical Scale Press Scale and use to adjust the vertical scale of the operation results 5 Center Frequency Press Center to adjust the frequency of frequency domain waveform relative to the horizontal center of screen 6 Horizontal Scale Press Scale and use to adjust the horizontal scale of frequency domain waveform 7 Select Window Function Spectral leakage can be considerably decreased when a window function is used DS1000Z provides four kinds of FFT window functions which have different characteristics and are applicable to measure different waveforms You need to select the window function according to different waveforms and their characteristics Press Window to select the desir
174. skManage File Type to select the desired file type The default is Under the current directory only files of which the suffix of the file name matches with the file type selected will be displayed in the current disk 13 8 DS1000Z User s Guide Chapter 13 Store and Recall RIGOL To Create a New File or Folder This operation of folder is only valid in external storage Before using external disk make sure that the USB storage device is connected correctly First press Storage gt Disk Manage and use to select and open the external disk Disk D Then select the desired file type Last select the desired directory under which to create a new file or folder The default is the root directory of the USB storage device Then press New File or New Folder to turn on the interface as shown in the figure below This oscilloscope supports Chinese English input method The file name or folder name can contain letters numbers underscores spaces and Chinese characters and the length of the characters is limited to 64 bytes The following part introduces how to input a file name or folder name using Chinese English input method Operation Tip During the name input use the menu softkeys to select different operation areas then turn 4 to select the desired content and press down 2 to input the content selected DS1000Z User s Guide 13 9 RIGOL Chapter 13 Store and Recall English Input Method For exam
175. specified upper limit of time Time Setting In this oscilloscope positive slope time is defined as the time difference between the two crossing points of trigger level line A and B with the positive edge as shown in the figure below 5 12 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL xxl b fL vM LL The upper limit of trigger level Up Level E ey eee L X The lower limit of trigger level Low Level Positive Slope time I e When the Slope Condition is set to MESSE MEIS E o EE press Time and use 42 to input the desired value The range available is from 8 ns to 10 s e When the Slope Condition is set to EIS EI press Upper Limit and Lower Limit and use amp 2 to input the desired values respectively The range of time upper limit is from 16 ns to 10 s The range of the time lower limit is from 8 ns to 9 99 s Note that the time lower limit must be lower than the upper limit Vertical Window Press Vertical to select the desired vertical window Note that under the Slope trigger menu you can also press down the trigger level knob continuously to switch the vertical window You can select the boundaries of the trigger level and then use TRIGGER t LEVEL to adjust the trigger level During the adjustment two orange trigger level dines and two trigger marks El and Erg appear on the screen and move up and down with the rotation of the knob while at the same time the
176. st value according to the current configration automatically HORI ZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results DS1000Z User s Guide 6 9 RIGOL Chapter 6 To Make Measurements OR Operation Perform logic operation on specified sources waveform point by point and display the results In operation when the voltage value of the source channel is greater than the threshold of the corresponding channel it is regarded as logic 1 otherwise logic 0 The following common logic operation expressions are provided The results of logic OR operation of two binary bits are as follows A B A B 0 0 0 0 1 1 1 0 1 1 1 1 Press MATH gt Math gt Operator to select A B Press Display to turn on or off the OR operation function Press Source Aand Source B to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use amp 2 to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Tre A and use 2 to set the threshold of source A in logic operation Press Tre B and use 4 amp 2 to set the threshold of source B in logic operation Press Options to se
177. stem of the oscilloscope Chapter 3 To Set the Horizontal System Introduce the functions of the horizontal system of the oscilloscope Chapter 4 To Set the Sample System Introduce the functions of the sample system of the oscilloscope Chapter 5 To Trigger the Oscilloscope Introduce the trigger mode trigger coupling trigger holdoff external trigger and various trigger types of the oscilloscope Chapter 6 To Make Measurements Introduce how to make math operation cursor measurement and auto measurement Chapter 7 Protocol Decoding Introduce how to decode the input signal using those common protocols Chapter 8 Reference Waveform Introduce how to compare the input waveform with the reference waveform Chapter 9 Pass Fail Test Introduce how to monitor the input signal using the Pass Fail test Chapter 10 Waveform Record Introduce how to analyze the input signal using waveform record Chapter 11 Display Control Introduce how to control the display of the oscilloscope Chapter 12 Signal Source Introduce how to use the built in signal source Chapter 13 Store and Recall Introduce how to store and recall the measurement result and the setting of the oscilloscope DS1000Z User s Guide XIII RIGOL Chapter 14 System Function Setting Introduce how to set the remote interface and system related functions Chapter 15 Remote Control Introduce how to control the oscilloscope remotely Chapter 16 Troubl
178. t result is displayed as it means that there is no signal input in the current source or the measurement result is not within the valid range too large or too small DS1000Z User s Guide 6 19 RIGOL Chapter 6 To Make Measurements Time Parameters RiseTime FallTime 90 Period 1 Period defined as the time between the middle threshold points of two consecutive like polarity edges Frequency defined as the reciprocal of period Rise Time the time for the signal amplitude to rise from 10 to 90 Fall Time the time for the signal amplitude to fall from 90 to 10 Width the time difference between the 50 threshold of a rising edge to the 50 threshold of the next falling edge of the pulse Width the time difference between the 50 threshold of a falling edge to the 50 threshold of the next rising edge of the pulse 7 Duty the ratio of the positive pulse width to the period 8 Duty the ratio of the negative pulse width to the period ey 9 6 20 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL Delay and Phase Source A Source B Source A and source B can be CH1 or CH2 1 Delay A B1 the time difference between the rising edges of source A and source B Negative delay indicates that the selected rising edge of source A occurred after the selected edge of source B 2 Delay A Bt the
179. t the data stays stable and constant before and after the clock edge appears Press Setup and Hold to set the setup time and hold time respectively and the range is from 8 ns to 1 s Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameters trigger holdoff and noise rejection under this trigger type Trigger Level Use TRIGGER 2 LEVEL to modify the level For details please refer to the description of Trigger Level on page 5 9 5 22 DS1000Z User s Guide Chapter 5 To Trigger the Oscilloscope RIGOL TimeOut Trigger Option Trigger when the time interval AT from when the rising edge or falling edge of the input signal passes through the trigger level to when the neighbouring falling edge or rising edge passes through the trigger level is greater than the timeout time set as shown in the figure below Time Out lt AT Time Out Trigger Type Press Type to select TimeOut At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 as the Trigger Source The current trigger source is displayed at the upper right corner of the screen Note select channel with signal input as trigger sour
180. t the same time press CursorAB and use to adjust the position of cursor A and B at the same time During the adjustment the measurement results will change accordingly The adjustable range is limited within the screen 4 Select X Y Axis Unit Press Units to set the horizontal unit and the vertical unit of the cursor measurement Press Hori Unit to select s Hz Degree or Percent s when this unit is selected in the measurement results AX BX and BX AX are in s and 1 dX is in Hz Hz when this unit is selected in the measurement results AX BX and BX AX are in Hz and 1 dX is in s Degree when this unit is selected in the measurement results AX BX and BX AX are in At this point AX BX and BX AX will change to 0 360 and 360 respectively when you press Set Range no matter where cursor A and B are currently located At the same time two cursor lines unmovable appear on the screen as the reference positions Persent when this unit is selected in the measurement results AX BX and BX AX are in At this point AX BX and BX AX will change to 096 100 and 100 respectively when you press Set Range no matter where cursor A and B are currently located At the same time two cursor lines unmovable appear on the screen as the reference positions Press Vert Unit to select Source or Percent Source when this unit is selected in the measureme
181. t the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Sens to set the sencitivity of the operation results and the range available is 0 div to 0 96 div Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results 6 10 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL XOR Operation Perform logic operation on specified sources waveform point by point and display the results In operation when the voltage value of the source channel is greater than the threshold of the corresponding channel it is regarded as logic 1 otherwise logic 0 The following common logic operation expressions are provided The results of logic KOR operation of two binary bits are as follows A B A B 0 0 0 0 1 1 1 0 1 1 1 0 Press MATH gt Math gt Operator to select A B Press Display to turn on or off the XOR operation function Press Source A and Source B to select the desired chann
182. tart the instrument DS1000Z User s Guide 1 13 RIGOL Chapter 1 Quick Start Front Panel Function Overview VERTI CAL ICH1 CH2 CH3 CH4 analog input channels The 4 channels are marked by different colors which are also used to mark both the corresponding waveforms on the screen and the channel input connectors Press any key to open the corresponding channel menu and press again to turn off the channel MATH press this key to open the math operation menu under which add subtract multiply divide FFT A amp amp B A B A B A intg diff sqrt Ig In exp and abs are provided REF press this key to enable the reference waveform function to compare the waveform actually tested with the reference waveform Source press this key to enter the source setting interface You can turn on or off the outputs of the Source1 and Source2 connectors at the rear panel edit the output signal and view the current signal status such as the frequency amplitude and phase Vertical POSITION modify the vertical position of the current channel waveform Turn clockwise to increase the position and turn counterclockwise to decrease During the modification the waveform would move up and down and the position message e g EMETA at the lower left corner of the screen would change accordingly Press down this knob to quickly reset the vertical position to zero VERTICAL SCALE modify the
183. tem 14 8 DS1000Z User s Guide Chapter 14 System Function Setting RIGOL Self calibration The self calibration program can quickly make the oscilloscope reach the best working state to get the most precise measurement values You can perform self calibration at any time especially when the change of the environment temperature is up to or more than 5 C Make sure that the oscilloscope has been warmed up or operated for more than 30 minutes before the self calibration Disconnect all the input channels and then press gt Self Cal and the self calibration interface as shown in the figure below is displayed H 1 00us everything from all inputs Press Start and the oscilloscope will start to execute the self calibration program Press Exit to give up the self calibration operation at any time and return to the previous menu Note most of the keys are disabled during the self calibration DS1000Z User s Guide 14 9 RIGOL Chapter 14 System Function Setting Option Management This oscilloscope provides multiple options to fulfill your measurement requirements Please contact your RIGOL sales representative or RIGOL technical support to order the corresponding options You can view the options currently installed on the oscilloscope or activate the newly bought option serial number through this menu Press Utility gt Options gt Installed to view the options currently installed on the oscilloscope Press Setup to
184. th Suspected Failures If you suspect damage occurs to the instrument have it inspected by qualified service personnel before further operations Any maintenance adjustment or replacement especially to circuits or accessories must be performed by RIGOL authorized personnel Keep Well Ventilation Inadequate ventilation may cause increasing of temperature or damages to the device So please keep well ventilated and inspect the intake and fan regularly Do Not Operate in Wet Conditions In order to avoid short circuiting to the interior of the device or electric shock please do not operate in a humid environment Do Not Operate in an Explosive Atmosphere In order to avoid damages to the device or personal injuries it is important to operate the device away from an explosive atmosphere Keep Product Surfaces Clean and Dry To avoid the influence of dust and or moisture in air please keep the surface of device clean and dry Electrostatic Prevention Operate in an electrostatic discharge protective area environment to avoid damages induced by static discharges Always ground both the internal and external conductors of the cable to release static before connecting Handling Safety Please handle with care during transportation to avoid damages to buttons knob interfaces and other parts on the panels DS1000Z User s Guide I RIGOL Safety Terms and Symbols Terms in this Manual These terms may appear in this manual WARNI
185. time difference between the falling edges of source A and source B Negative delay indicates that the selected edge of source A occurred after the selected edge of source B 3 Phase A B1 phase difference calculated according to Delay A gt B and the period of source A expressed in degree 4 Phase A Bt phase difference calculated according to Delay A Bt and the period of source A expressed in degree Delay The Period of Source A Red Phase DS1000Z User s Guide 6 21 RIGOL Chapter 6 To Make Measurements Voltage Parameters Overshoot ee IMEEM Vtop Vpp Vamp Vbase Vmin Preshoot 1 Vmax the voltage value from the highest point of the waveform to the GND 2 Vmin the voltage value from the lowest point of the waveform to the GND 3 Vpp the voltage value from the highest point to the lowest point of the waveform 4 Vtop the voltage value from the flat top of the waveform to the GND 5 Vbase the voltage value from the flat base of the waveform to the GND 6 Vamp the voltage value from the top of the waveform to the base of the waveform 7 avg the arithmetic average value on the whole waveform or on the gating area X Waag n wherein iis the ith point being measured Nis the number of points being measured 8 Vrms the root mean square value on the whole waveform or the gating area where iis the ith point being measured is the number of points being
186. tor for an IP address available Press IP Address and use 2 to input the desired IP address This setting will be saved in the non volatile memory and if Power on Recall is set to Last DHCP and Auto IP will be Off and the oscilloscope will load the preset IP address automatically at the next power on 2 Setthe Subnet Mask The format of the subnet mask is nnn nnn nnn nnn wherein the range of the nnn is from 0 to 255 You are recommended to ask your network administrator for a subnet mask available Press Mask and use amp 2 to input the desired subnet mask This setting will be saved in the non volatile memory and if Power on Recall is set to Last DHCP and Auto IP will be Off and the oscilloscope will load the preset subnet mask automatically at the next power on Set the Gate You can set this paramter In Auto IP and Static I P mode The format of the gate is nnn nnn nnn nnn wherein the range of the first nnn is from 0 to 223 except 127 and the ranges of the other three nnn are from 0 to 255 You are recommended to ask your network administrator for a gate address available Press Gate and use 2 to input the desired gate address This setting will be saved in the non volatile memory and if Power on Recall is set to Last DHCP and Auto I P will be Off and the oscilloscope will load the preset gate address automatically at the next power on Set the Domain Name Server You can set this paramter In Auto IP and Stat
187. trigger level value and the slope value are displayed at the lower left corner of the screen When stopping turning the knob the trigger level lines and trigger mars disappear in about 2 s When the Slope Condition is set to ae mew the current trigger level and slope range will be displayed at the lower left corner of the screen UpLevel LowLevel SlewRate Time UpLevel LowLevel MinRate MaxTime UpLevel LowLevel MinTime MaxRate DS1000Z User s Guide 5 13 RIGOL Chapter 5 To Trigger the Oscilloscope The adjustment mode of the trigger level is different when different vertical window is selected e a only adjust the upper limit of the trigger level During the adjustment UP Level and Slew Rate change accordingly but Low Level remains dus d E x Low Level and Slew Rate change accordingly b k UP Level remains unchanged e adjust the upper and lower limits of the trigger level at the same time During the adjustment UP Level and Low Level change accordingly but Slew Rate remains unchanged Trigger Mode Press Sweep to select the Trigger Mode page 5 3 under this trigger type as auto normal or single The corresponding status light of the current trigger mode turns on Trigger Setting Press Setting to set the trigger parameters trigger holdoff and noise rejection under this trigger type 5 14 DS1000Z User s Guide Chapter 5 To Trig
188. umber of cursors Note that no cursor will be displayed if no auto cursor measurement parameter is enabled or the measurement source has no input When the waveform is expanded or compressed horizontally the cursor will move accordingly If multiple measurement parameters are turned on later you can use Auto I tem to switch among at most five measurement parameters that are turned on last The following figure shows the auto measurement of the rise time of sinusoidal signal H 1 00us Horizontal iil Mt Quick1 DS1000Z User s Guide 6 35 Chapter 7 Protocol Decoding RIGOL Chapter 7 Protocol Decoding Protocol analysis can be used by users to discover errors debug hardware and accelerate development easily so as to guarantee quick and high quality accomplishment of projects Protocol decoding is the basis of protocol analysis Only protocol analyses with correct protocol decoding are acceptable and only correct protocol decoding can provide more error information DS1000Z provides two buses to make common protocol decoding including Parallel standard RS232 option 12C option and SPI option of the analog channels CH1 CH4 As the decoding functions and setting methods of the two buses are the same this chapter only takes Decode for illustration To get the decoding option information please refer to Appendix A Accessories and Options When you have ordered the decoding option please refer to
189. ution This mode uses a kind of ultra sample technique to average the neighboring points of the sample waveform to reduce the random noise on the input signal and generate much smoother waveforms on the screen This is generally used when the sample rate of the digital converter is higher than the storage rate of the acquisition memory Note Average and High Res modes use different averaging methods The former uses multiple sample average and the latter uses signle sample average Sin x x Press Sin x x to enable or disable the dynamic sine interpolation function Enable the dynamic sine interpolation can restore the original waveform more real 4 4 DS1000Z User s Guide Chapter 4 To Set the Sample System RIGOL Sample Rate The sample rate of this oscilloscope is up to 1 GSa s Note that the sample rate is displayed in the status bar at the upper side of the screen and in the Sa Rate menu and can be changed by adjusting the horizontal time base s div through HORIZONTAL gt SCALE or modifying the memory depth The influence on the waveform when the sample rate is too low 1 Waveform Distortion when the sample rate is too low some waveform details are lost and the waveform displayed is rather different from the actual signal NINE 2 Waveform Confusion when the sample rate is lower than twice the actual signal frequency Nyquist Frequency the frequency of the waveform rebuilt from the samp
190. utomatically HORIZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the horizontal position and scale of the operation results 6 12 DS1000Z User s Guide Chapter 6 To Make Measurements RIGOL Integrate Calculate the integral of the specified signal source For example you can use integrate to calculate the energy of a pulse or measure the area under a waveform Press MATH gt Math gt Operator to select intg Press Display to turn on or off the integral operation function Press Source to select the desired channels CH1 CH2 CH3 or CH4 Press Offset and use 2 to adjust the vertical offset of the operation result Press Scale and use to adjust the vertical scale of the operation results Press Scale Reset the instrument will adjust the vertical scale to the best value according to the current configration automatically Press Options to set the start point end point or turn on or off the inverted display of the operation results Press Start to set the start point of the operation results Press End to set the end point of the operation results Press Invert to turn the inverted display of the operation results on or off Press Auto Scale to turn on or off the auto scale function When ON is selected the instrument will adjust the vertical scale to the best value according to the current configration automatically HORIZONTAL POSITION and HORIZONTAL SCALE can also be used to adjust the
191. value of the measurement Reducing the maximum value to the current Mid will automatically reduce the Mid to keep it lower than the maximum value The default is 9096 and the range available is from 796 to 9596 Press Mid and use amp 2 to set the middle value of measurement The middle value is limited by the settings of Max and Min The default is 5096 and the range available is from 696 to 9496 Press Min and use 2 to set the minimum value of the measurement Increasing the minimum value to the current Mid will automatically increase the Mid to keep it higher than the minimum value The default is 1096 and the range available is from 596 to 9396 DS1000Z User s Guide 6 25 RIGOL Chapter 6 To Make Measurements To Clear the Measurement If you have currently enabled one or more items in the 24 measurement parameters you can Delete or Recover the first five parameters or Delete or Recover all the measurement items enabled Note that the first five parameters are determined according to the order in which you turned them on and they will not change as you delete one or more measurement items Press gt Clear gt Item n to Delete or Recover the specified measurement item When one measurement item is deleted or recovered the measurement result at the bottom of the screen will move one item left or right Press Measure gt Clear gt All Items to Delete or Recover all the measu
192. vertical scale of the current channel Turn clockwise to decrease the scale and turn counterclockwise to increase During the modification the amplitude of the waveform would enlarge or reduce and the scale information e g 1 AMETE at the lower side of the screen would change accordingly Press down this knob to quickly switch the vertical scale adjustment modes between Coarse and Fine 1 14 DS1000Z User s Guide Chapter 1 Quick Start RIGOL HORI ZONTAL HORIZONTAL HORI ZONTAL POSITION modify the horizontal position The trigger point would move left or right relative to the center of the screen when you turn the knob During the modification waveforms of all the channels would move left or right and the horizontal position message e g at the upper right corner of the screen would change accordingly Press down this knob to quickly reset the horizontal position or the delayed sweep position scale MENU press this key to open the horizontal control menu under which to turn on or off the delayed sweep function switch between different time base modes HORI ZONTAL SCALE modify the horizontal time base Turn clockwise to reduce the time base and turn counterclockwise to increase the time base During the modification waveforms of all the channels will be displayed in expanded or compressed mode and the time base message e g CEH at the upper side of the screen would change accordingly Press down thi
193. waveform record are also supported Print E pressing this key will save the screen to the USB storage device in png format If the current storage type is picture the screen will be saved in the USB storage device in picture format BMP8 BMP24 PNG and TIFF 1 18 DS1000Z User s Guide Chapter 1 Quick Start RIGOL User I nterface DS1000Z provides 7 0 inches WVGA 800 480 160 000 color TFT LCD 1 23 4 5 6 7 8 9 10 11 T Coupling 5 DC BW Limit OFF Probe 1X ENIM OFF Parameter Limited 12 13 14 15 16 17 18 19 20 Figure 11 User Interface 1 Auto Measurement I tems Provide 12 horizontal HORIZONTAL and 12 vertical VERTICAL measurement parameters Press the softkey at the left of the screen to activate the corresponding measurement item Press MENU continuously to switch between the horizontal and vertical parameters 2 Channel Label Waveform Different channels are marked by different colors and the color of the waveform complies with the color of the channel 3 Status Available states include RUN STOP T D triggered WAIT and AUTO 4 Horizontal Time Base Represent the time per grid on the horizontal axis on the screen DS1000Z User s Guide 1 19 RIGOL Chapter 1 Quick Start Use HORIZONTAL gt SCALE to modify this parameter The range available is from 5 ns to 50 s 5 Sample Rate Memory Depth Display the current sample rate and memory dept
194. y 0 C to 30 C lt 95 relative humidity 30 C to 40 C lt 75 relative humidity 40 C to 50 C lt 45 relative humility WARNI NG To avoid short circuit inside the instrument or electric shock please do not operate in humid environment Altitude Operating less than 3 km Non operating less than 15 km Installation overvoltage Category This product is powered by mains conforming to installation overvoltage category Il WARNING AN Make sure that no overvoltage such as that caused by thunderbolt can reach the product or else the operator might expose to danger of electric shock Installation overvoltage Category Definitions Installation overvoltage category refers to signal level which is applicable to equipment measurement terminals connected to the source circuit In these terminals precautions are done to limit the transient voltage to the corresponding low level Installation overvoltage category I1 refers to the local power distribution level which is applicable to equipment connected to the AC line AC power DS1000Z User s Guide VII RIGOL Pollution Degree Degree 2 Pollution Degree Definitions Pollution degree 1 No pollution or only dry non conductive pollution occurs The pollution has no influence For example a clean room or air conditioned office environment Pollution degree 2 Normally only dry non conductive pollution occurs Occasionally a temporary conductivity caused b
195. y condensation may occur For example general indoor environment Pollution degree 3 Conductive pollution occurs or dry non conductive pollution occurs which becomes conductive due to condensation which is expected For example Sheltered outdoor environment Pollution degree 4 Pollution that generates persistent conductivity through conductive dust rain or snow For example outdoor locations Safety Class Class 1 Grounded Product VIII DS1000Z User s Guide RIGOL General Care and Cleaning General Care Do not store or leave the instrument at places where the instrument will be exposed to direct sunlight for long periods of time Cleaning Clean the instrument regularly according to its operating conditions To clean the exterior surface 1 Disconnect the instrument from all power sources 2 Clean the loose dust on the outside of the instrument with a lint free cloth with mild detergent or water When cleaning the LCD take care to avoid scarifying it A CAUTI ON To avoid damages to the instrument do not expose them to corrosive liquids WARNI NG AN To avoid injury resulting from short circuit make sure the instrument is completely dry before reconnecting it to a power source DS1000Z User s Guide IX RIGOL Environmental Considerations The following symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002 96 EC on waste
196. ype Trigger Level Use TRIGGER LEVEL to modify the level For details please refer to the description of Trigger Level on page 5 9 DS1000Z User s Guide 5 11 RIGOL Chapter 5 To Trigger the Oscilloscope Slope Trigger Trigger on the positive or negative slope of specified time Trigger Type Press Type to select Slope At this point the trigger setting information as shown in the figure below is displayed at the upper right corner of the screen Source Selection Press Source to select CH1 CH4 as the Trigger Source The current trigger source is displayed at the upper right corner of the screen Note select channel with signal input as trigger source to obtain stable trigger Slope Condition Press When to select the desired slope condition e tam trigger when the positive slope time of the input signal is greater than the specified time e E trigger when the positive slope time of the input signal is lower than the specified time e Eg trigger when the positive slope time of the input signal is greater than specified lower limit of time and lower than the specified upper limit of time e ELM trigger when the negative slope time of the input signal is greater than specified time e EET trigger when the negative slope time of the input signal is lower than the specified time e BELA trigger when the negative slope time of the input signal is greater than the specified lower limit of time and lower than the