1. A WARNING Read the technical instructions before installing the bath e Read the users instructions before using the bath e Donot bring sharp objects into the bath e Contact the seller if the colours appear to be changing under or on top of the coating e fa leakage appears contact the seller immediately e All electrical work should be perfomed by a qualified electrician e Do not leave children in the bath without supervision e Do not sit with your back or head against the skimmer e For AquaKing a mains connection of 230V 1x16A 2x16A with Ground Fault Current Interrupt GCFI is required A service switch which is closely installed to the electrical connection is recommended e ATTENTION If the hot tub will be integrated e g into a terrace it is necessary that the access is not obstructed in any way order to be able to service it Service hatch and outer panel should be removable without difficulties e f automatic dispensers floating etc are used careful adjustment should be made to avoid incorrect dosage Follow the recommendations in our instructions e The circulation pump also generates heat and if it is running a long time eg continuous filtration TM it can raise the temperature by several degrees in one day when the tub is well insulated e Check the quality of the water as well as temperature and function regularly don t leave the spa unmonitored for long time periods a oS amp SpaDea
2. alve 3 on the right side of the filter by pressing it down 3 Be prepared to close the valve C the one closest to the bottom to the left of the pump when the pump stops This is important to do so water will not flow back into the filter cartridge holder 4 Unscrew the nut and take off the filter s top piece Now it is possible to clean the filter lt would be good to have a spare one Assemble it in an opposite order tighten the nut on the cartridge holder leave it slightly loose so it will be easier to reopen it Tighten the nuts of the filter container properly Open 1 amp 2 and let air escape Close when water starts trickling out Now the pump can be started via the control panel Draining of water There is a valve V close to the circulation pump installed in order to drain water see picture to the right In case the spa bath needs to be emptied for a longer period or if there might be a risk of frost then please keep in mind to empty the circulation pump and the massage pump if included very carefully as well 1 Open cover where filter and pump s are installed Open valve V and drain the water via the drain hole 2 Loosen the lowest nut belonging to the pumps A This one does not to be loosened totally just so that water can drain Please do the same with the nuts of the filter B and please do keep them open 3 Loosen the nuts which are connected to the bubble system and give the hose a good blow a few times ti
3. d together with A V key If the TEMP key is pressed for 5 seconds the panel will display the water temperature set last time This temperature will keep flashing Press the A key to adjust the temperature to the highest at 42 press the Y key to adjust the temperature to the lowest at 10 The new temperature will be automatically stored and the display will then return to show the current water temperature after flashing for 60 seconds or 1f the or button is used e RADIO AV key Radio DVD Control and display of temperature When the control systems are ready to work press the RADIO AV key to activate the Radio function The panel will now show the radio channel set last time under Radio status press key to select pre stored radio stations a second press will activate the TV function this function is optional The panel will now show a TV symbol A third press will activate the DVD function this 2 USER MANUAL for the SG 0007B SYSTEM function is optional The panel now shows a DVD symbol at the same time Under DVD status press the key to adjust the volume of the DVD Press for the fourth time to show the detected water temperature TUN VOL key needs to be used together with the key Under Radio status first press the TUN VOL key The panel will now show a 2 digit volume pressing will adjust the volume upwards or downwards the panel will automatically show the radio frequency when you stop adju
4. e the blowers built in thermal protection might activate The blower will stop and not restart until it s cooled down enough You can speed up the cooling by opening the service hatch es In doing so please protect the equipment from potential freezing damage 4
5. e to the control system for use during maintenance work C An earth switch must be installed Check that the earth switch works when the power is connected SG0007B Sketch Of Linking Wires For The System C OZONIZER X B ER g O wm s O CDANPUT Ur ie A mm f i il i i pea Sub Woofer 2 T OO Antenna ll ZN zz Meere a ZN PT ZN AL ns DVDIPOWER Fi m em Pt RR ee y f to Y RI us TEMPERATURE a a dl dl 4 SENSOR LAMP LED WATER LEVEL l JOD O O0 da ll a y UP DOWN HEATER FECGCLEPUMP BUBBLE AGHNPUT AATERPUME WATERPUMP2 MATER PUMPI LIMIT SWITCH MOTOR WIRING DIAGRAM 3 phase 2 phase 1 phase i connecting LI LI L3 NE 2 connecting LI LI NE only 3 connecting L N E only L L 380k E N 230 23013 ELABORA L N 220 VU 2300 L N 220V 330 Figure 1 l USER MANUAL for the SG 0007B SYSTEM II Operating instructions Fig 2 e ON OFF key power key Connect the power supply and press the ON OFF key All the control systems are now ready to run indicator light is on and the circulation and Ozone disinfection system if one exists will start working automatically if the water temperature is not at the pre set temperature the heating system will start to work n 60 seconds The panel will display the circulation and Ozone symbols a symbol for the heating system will also be displayed o1 yanel if the heating system 1s working The panel will also display the detected water temperature N
6. ed the filtration pump and thus the filtration is on continiously 24h per day without stopping in between Automatic working mode Automatic working mode is on by default Press and hold the key for 3 seconds to switch over to automatic mode The button will light up The circulation pump starts and runs for 1 hour the display panel will cycle between ON and water temperature indicator key will light up After 1 hour the pump will stop for 3 hours the display panel will cycle between OFF and water temperature indicator key 2 will light up As long as the system is in automatic mode this filtration cycle will repeat indefinitely The keys 1 2 and 3 FILTER PROGRAM are non functional keys and only act as indicators NOTE gt Ifthe spa is in automatic working mode please don t turn off the spa when not in use Make sure the spa is always on gt When in automatic mode the filtration pump will also be controlled by temperature If the water temperature is lower than the preset level during the OFF period the filtration pump and heater will work until the water temperature has reached the preset level Then the filtration pump will return to work for 1 hour and stop for 3 hours repeatedly When the automatic mode is not in use the circulation pump is always on If the water temperature drops 2 under the pre set level the heater will activate gt Each time the spa is switched on the system will go into t
7. he previously set mode Press and hold the or key for 3 seconds the indicator will show GREEN to switch between automatic mode and manual mode Summary and If is selected the filtration is handled automatically in cycles of 1 hour on 3 hours off If is selected the filtration pump and thus the filtration is on continuously 24h per day without stopping in between If the preset temperature is higher than the actual water temperature then both the circulation pump and heater are activated until the water temperature reaches the chosen setting The Ozone will automatically work together with the filtration pump and heater This applies in both and modes WARNING The circulation pump also generates heat and 1f it is running a long time eg continuous filtration TM it can raise the temperature by several degrees in one day when the tub is well insulated Avoid using the TM function other times than when the water needs to be filtered further Always check water quality and temperature after using TM for one day FILTRATION PUMP NOTE If the hot tub is equiped with a massage pump it will connected to WATER PUMP 1 If there are two massage pumps the second is connected to WATER PUMP 2 UV C OZONE CLEANER If an UV C ozoner cleaner is installed connect it so that it activates the same time as the circulatory pump BLOWER BUBBLE ATTENTION If the blower is used often and for prolonged periods of tim
8. lash continuously to remind the user that it is time to clean or replace the filtration medium After cleaning or replacing the filtration medium press ON OFF several times to expel the air inside the pipe until the filtration pump works normally Anti freezing system After power on to enter standby status the indicator light on ON OFF key flashes the anti freezing system will be activated instantly The circulation pump and heating system will automatically stop at the default temperature of above 10 When the water temperature in the spa drops below 9 the circulation pump heater and air blower will work automatically Jet accessory will automatically start to work in about 85 seconds and it will stop after working about 85 seconds then Jet2 if equipped will start to work for about 85 seconds and stop finally Jet3 starts to work if equipped for about 85 seconds then stops Pumpl Pump2 and Pump3 will continuously cycle among themselves When the detected water temperature reaches 10 all the pumps and heater will stop working When this system is running the screen background light is on When the water temperature reaches 10 the screen returns to the standby status USER MANUAL for the SG 0007B SYSTEM Manual working mode Turn on the spa then press and hold the key for 3 seconds to enter manual mode the indicator light on the key will show GREEN when in manual mode indicator key 3 will light up If 1S select
9. lers E 4 A 4 d 1 J Where Quality and Service meet Picture 2 show how the air pump for the bubble system 1s placed It should not be oriented with the air exhaust upwards If the AquaKing is equipped with the BactiSafe accessory then it is positioned according to picture 1 The control system is fastened in the position that is shown in picture 2 Connect the nut to pump and filter properly picture 3 _POLYURETANE gt When installing the insulated box insulating foam polyurethane will be applied between the side insulation of the spa bath and the boxe s insulation see picture The insulation beneath the lid of the box should not be used when the temeprature indicates more than 10 degrees To protect BactiSafe against damage from freezing it should be drained by loosening the stainless nut and the sealing around the glass tube Lowering into terrace ATTENTION If the hot tub will be countersunk e g in a terrace it is necessary that the access 1s not obstructed in any way order to be able to service 1t Service hatch and outer panel should be removable without difficulties CLEANING AND CHANGING THE FILTER All screw connections must use the rubber seals provided Own Assembly During assembly of wall and base fittings silicone shall be used on both sides of the connections as well as the threads ATTENTION Near the bottom of the filter holder there is an arrow which must be pointed towards the pum
10. ll water runs out 4 NOTE If the control systems model nr Is TM42 A1 then the blower air pump can be started via the control panel Let it run for a few seconds before turning it off again Attention When the spa is to be drained of water for a longer period of time or if there is a risk of freezing then the circulating pump massage pumps and nuts for pumps and filters shall be left open If draining is done only for changing the water it is not necessary to drain the pumps of water or open these connections Also read Avoid damage from freezing Avoid damage from freezing e Plan the draining and filling of water so that there is no risk of damage from freezing never empty or fill the bath when the temperature s below freezing without first protecting the equipment e Attention If the bath has been emptied of water and the temperature s below freezing then all the equipment will also be below freezing itself If the bath is filled with water then without considering this the risks of freezing damage is great e For protection against freezing damages the interior of the bath can be warmed up beforehand Use for instance an interior car heater or electric heater and set the temp to 20 degrees celsius and place it inside the box where the pumps are installed as well e If the water level drops below the massage nozzles they are automatically drained of water when the air regulator on the the edge is in open moden Is the air reg
11. ode When in interlock mode the heater will stop when you press any of the pump and bubble keys This feature is meant to reduce the power needed for the spa so that it can match the power limit of some countries 1 x 16A In non interlocked mode the heater will keep running when the other pumps are activated unless the water temperature reaches the set temperature NOTE That requires at least a 2 phase connection if the total effect for pumps and heating exceeds 3680 W Temperature sensor self checking system If El is displayed on the panel then the temperature sensor is disconnected In this situation check the wiring of the temperature sensor to see if t s properly connected If EO is displayed on the panel then the temperature sensor has short circuited In this case the temperature sensor must be replaced The heating system cannot be activated under the two above situations Water lacking protection system for circulation pump and heater In daily usage a blockage of the filtration medium cartridge filter or filter bag will eventually occur A severe blockage will lead to a lack of water for the filtration pump Air in the system often leads to the same problem For instance during startup if aeration has not been performed according to the instructions in the manual When there is a lack of water the filtration pump and heater will stop working automatically At this moment the symbol of the filtration pump on the control panel will f
12. ote If no button is pressed within 60 seconds the displays backlight goes off it reactivates if a button is pressed e PUMP key press the JET1 key Its symbol will now appear on the panel signifying that massage pump 1 has been activated JET2 and JET3 work in the same way and have their own symbols with numbers 2 and 3 on them JET1 JET2 AND JET3 are accessories for some spa models NOTE The massage system will shut down automatically in 20 minutes NOTE There are some air valves on the topside of spas near the seats They are to control the strength of the hydro massage in the respective seats e BUBBLE key Press the key Its symbol will appear on the panel meaning that the air massage system has started working NOTE The blower automatically shuts down after 20 minutes e 03 key Ozone Pressing the 03 key will turn on or off the Ozone disinfection system Ozone and circulation pump work automatically when activating the spa NOTE Ozone can be an accessory and another alternative is the UV C ozone cleaner See UV C Ozone Cleaner under Summary e LAMP key When the control systems are ready to work first press the ke ts symbol will now appear on the panel signifying that the underwater lights are on the colour will change automatically with a second press the color will be fixed on a certain color press for the third time to shut it off NOTE The lamp shuts off automatically after 60 minutes e TEMP key needs to be use
13. p The control system should also be connected if it s included This must be done by a qualified electrician Close the valves on the filter before filling the Hot Tub STARTUP When the system is ready for testing open the air screw 1 on top of the filter holder and the nut 2 Close it again when water begins to leak out After this procedure the system is ready for use Do not start the system without any water running and watch out that both the tap next to the filter suction side as well as the tap on the pressure side are open meaning the part connected to the pump not the draining valve WATERLEVEL The preferred water level for keeping the filtration working optimally is about 5 cm below the skimmers upper edge If it is beneath the skimmer then the pump could start sucking air instead of water into the filter and the control system then shuts off the pump and heating CLEANING AND CHANGING THE FILTER SpaDealers Cleaning change of filter AquaKing For a good water hygiene it is very important that the filter gets cleaned on a regular basis At least every second week it should be rinsed Every second month or whenever it is required it needs to get cleaned thoroughly with a special solution 1 Open the hatch where filter and circulation pump are placed Start the pump keep the T A button pressed until it starts if it s not already running 2 Open the screw 1 for the air above the filter top piece Close the v
14. sting for 3 seconds With a second press the current frequency will flash Pressing the key will adjust the current frequency This frequency will be stored automatically after flashing for 3 seconds With a third press the panel will show the radio channel Press the key to select pre stored radio stations the panel will automatically show the previous radio frequency after you stop adjusting for 3 seconds With a long press for 5 seconds the system will automatically search for radio frequencies again and store the searched frequencies at a different channel sequentially Heating system After the control systems are ready to work the heater will start working 60 seconds after the circulation pump is activated unless the temperature sensor detects that the set temperature is lower than the detected one When the water temperature reaches a set temperature the heater will stop working automatically When the water temperature is under 2 of the preset one the heater will reactivate The symbol for the heater is located above the circulation pump symbol it appears as pulsing bubbles NOTE The heater will not be activated if there is not enough water flow Interlocked system between the heater and pumps Pressing and holding the ON OFF key again for 20 seconds will change the system between interlock mode or non interlock mode the indicator light on the ON OFF key shows RED in interlock mode while it shows GREEN in non interlock m
15. ulator is closed then water can remain in the transparent 12 mm hoses and cause freezing damage Always keep the air regulator in open mode when draining the spa e To protect BactiSafe against damage from freezing it should be drained by loosening the stainless nut and the sealing around the glass tube USER MANUAL for the SG 0007B SYSTEM This product is meant to be used for electronic control of functions for spa baths Please read all of the instructions carefully before enjoying the spa WARNING Operating the system without water will cause severe damage Contains electronic components shock hazard Does not contain user serviceable parts Do not try to repair the control unit Contact your dealer or service center for help Follow all user instructions I Installation 1 Open the door cover according to the instructions and connect the power supply correctly Warning A Installation 1s only to be made by qualified persons B Read the instructions carefully before beginning the installation C We are not responsible if the product does not work or is damaged when the instructions are not followed during installation D Ensure that the system 1s not damaged during transportation when it s unpacked A 1x16A Read Interlocked system between the heater and pumps 2 x 16A or 3 x 16 should be connected to the control system Do not connect the power before the installation is complete B Install a maintenance switch clos