Home
        Operating Instructions - Karl Klein Ventilatorenbau GmbH
         Contents
1.  IIB or IIC  T4 T135   C   DSV 4     II  2 oder 3  GD c  IIB or IIC  T4 T135  C   DHV     Il  2 or 3  GD c  IIB or IIC  T4 T135  C     Purpose of the operating manual    This operating manual accompanies the equipment  It also contains the installation  instructions    The operating manual was prepared by the manufacturer on the basis of their knowledge  and experience with design  production and operating procedures     The operating entity may supplement this manual with special instructions  for instance for  supervisory and reporting duties  operating specific maintenance and care schedules   in  particular to establish special cleaning intervals to remove dust deposits on the motors     Symbols used in this operating manual    The graphic representations and drawings are basic illustrations of a blower  They are not to  scale and do not correspond to the proportions of all blowers in the product range   These illustrations are only intended as a guide     Detailed dimensions and views are shown in the catalog     Copyright  The copyright for this operating manual remains with KARL KLEIN Ventilatorenbau GmbH     This operating manual may not be reproduced in whole or in part without prior approval by  KARL KLEIN Ventilatorenbau GmbH        04 2014 KARL KLEIN Ventilatorenbau GmbH Page 3    Operating manual for radial blowers for areas subject to gas and dust explosion hazards    1 Preliminary          1 Preliminary remarks    1 1 Manufacturer s instructions to the operatin
2.  is mounted  directly to the blower has been mandatory since May 2007 on blowers operating in zone  21     Blowers can be procured from Karl Klein with the corresponding devices installed  In this  case  the customer will be provided with an installed vibration sensor and an optional   separate monitoring device     The monitoring device must be installed outside of the explosive area  Please refer to the  corresponding operating manuals        When implementing a customer designed solution  the following issues need to be taken  into consideration     e Only vibration sensors that are certified for zone 21 may be used     e The vibration sensor should preferably be installed on the A side bearing enclosure  of the drive motor  in a horizontal orientation to the installation orientation     e The nominal sensor signal must be transmitted to a control or monitoring device that  is located outside of the explosive area  The control must shut the blower down if the  blower reaches critical vibration levels     8 1 Vibration threshold values                Threshold values in Rigid mount Flexible mount  accordance with ISO mm s mm s  14694  Starting value 4 5 6 3  Alarm threshold 7 1 11 8  Cut off value 9 0 12 5                   The values apply to blowers in industrial settings     9 Disposal    Reusing defective blowers and or their components  such as the blower impeller wheels   roller bearings  etc  can result in property damage and personal injury  as well as damage to  th
3. LZ    KLEIN    Operating Instructions    For all radial blowers for use in category  1 and 2  21 and 22 explosive atmospheres       Operating manual for radial blowers for areas subject to gas and dust explosion hazards          Printed in Germany    We reserve the right to change the information and illustrations shown in this operating  manual made as a result of technical advancements  The reprint  translation and  reproduction of any kind  including excerpts  require the manufacturer s written approval     This operating manual is not subject to update services   You may inquire with the manufacturer for the most current revision     KARL KLEIN Ventilatorenbau GmbH    WaldstraBe 24D 73773 Aichwald  Phone    49 7 11   36 90 6 0  Fax    49 7 11   36 90 6 50  Internet  www karl klein de   e mail  info karl klein de    Revision  04 2014       04 2014 KARL KLEIN Ventilatorenbau GmbH Page 1    Operating manual for radial blowers for areas subject to gas and dust explosion hazards       Table of Contents    KLEIN       Table of Contents    1 Preliminary remarks asses 4  1 1 Manufacturer s instructions to the operating entity           eeeeeesseeeseseeeessrrssernesrirrssrirrnsrennnnne 4  1 2 Operating entity obligations for blowers located in explosive atmospheres             0  00 4  1 3 SVMBOIS USOC ss acer as Arends seceatacvantybasedee A E AA 6  1 4 Type plates and instruction labels   00 0 0    eeeeseeeeeeeneeeeeeeeeeeeeaeeeeeeaaeeeeeeaaeeeeeeaeeeeneaeeeeneaa 7  2 D SIQN ate
4. alog    If work must be performed in the vicinity  appropriate noise protection steps must be taken  by the operating entity as part of its duties in accordance with the Operational Safety  Directive  BetrSichV or equivalent other national regulations   for instance hearing protection     3 1 3 Vibrations    KLEIN blowers are designed to such a high balance quality grade that no dangerous  vibrations will occur    The vibrations resulting from the unavoidable residual imbalance can be reduced by  installing the equipment with vibration dampers  thus preventing the vibration from being  transferred to other components     External vibrations or impacts must be prevented from being transferred to the blower  The  blower must not be exposed to dynamic forces     3 2 Overheating protection    To avoid potential overheating  the operating entity can request a thermal winding protector  when placing the order     Under all circumstances  the operating entity must avoid excessive dust buildup on the  surface by timely cleaning  The dust buildup must not exceed a thickness of 5mm        04 2014 KARL KLEIN Ventilatorenbau GmbH Page 10    Operating manual for radial blowers for areas subject to gas and dust explosion hazards       4 Transportation and Storage       4 Transportation and storage     i   Instruction     To transport and install the equipment safely  a suitable lifting strap should be used  The  blower should be secured in such a way that balance is maintained    Only tran
5. ance with RL 94 9 EC and Operational Safety Directive   BetrSichV or equivalent other national regulations       In reference to EN 1127 1  this means for Zone 1 that the blower is intended for use in those  areas where an atmosphere capable of producing an explosion  in the form a mixture of  combustible gas  vapor or mist with air  may occasionally form under normal operating  conditions    In reference to EN 1127 1  this means for Zone 2 that under normal operating conditions  an  atmosphere capable of producing an explosion  in the form a mixture of combustible gas   vapor or mist with air  normally does not form or only forms for brief periods    In reference to EN 1127 1  this means for Zone 27 that the blower is intended for use in  those areas where an atmosphere capable of producing an explosion  in the form of a  combustible dust cloud mixed with air may occasionally form under normal operating  conditions    In reference to EN 1127 1  this means for Zone 22 that under normal operating conditions   an atmosphere capable of producing an explosion  in the form of a combustible dust cloud  mixed with air  normally does not form or only forms for brief periods     The designated use encompasses observing and complying with the specifications and  instructions in this operating manual     2 1 Limitations to the use and special considerations for  designated uses    The designated operation also includes     e The conveyed medium may not contain solid or liquid contaminan
6. arly inspected for contamination and cleaned to identify  imbalances of the blower wheel early  and to prevent imbalances     7 2 Inspect and exchange bearings    e Inspect the unimpeded operation of bearings in regular intervals by monitoring the  operating noises  replace as needed     e The ball bearings must be replaced by the manufacturer or an authorized repair shop  after no more than 18 000 operating hours or 3 years     7 3 Repair instructions and procedures    Do not perform customer repairs on defective  damaged or unevenly running blowers  but  send the equipment to the manufacturer for repair    The manufacturer will ensure that repairs are performed properly and that the equipment is  properly balanced     Only qualified and trained personnel should perform the disassembly of the blower   AN Attention  Potential for damage to the  equipment     When balancing weight clips  1  are relocated or  removed from the blower fins  an imbalance results     Never perform repairs on the blower on your own  If  the assembly is not performed properly  any  subsequent use may create an explosion hazard     006_KL01_01          04 2014 KARL KLEIN Ventilatorenbau GmbH Page 16    Operating manual for radial blowers for areas subject to gas and dust explosion hazards       7 Maintenance  care and repair instructions       8 Additional steps to be taken when deploying blowers in  zone 21     i   Instruction     Pursuant to DIN EC 14986  a permanent vibration monitoring system that
7. ating manual  in particular the designated uses  are not complied with     Any unauthorized reconfiguration or modification of the blower is prohibited   Only use replacement parts and accessories that were approved by KARL KLEIN  Ventilatorenbau GmbH  The use of other parts may impair the function     The operating entity is liable for any resulting damages     KARL KLEIN Ventilatorenbau GmbH does not assume liability or honor warranty claims for  damages resulting from customer performed repairs or an incorrect blower installation        04 2014 KARL KLEIN Ventilatorenbau GmbH Page 5    Operating manual for radial blowers for areas subject to gas and dust explosion hazards       1 Preliminary       1 3 Symbols used    This operating manual uses the following symbols  These are complementary to safety and  damage prevention instructions     AN Attention Electrical Power Shock     Designates potentially occurring hazardous situations  Not observing these warning labels  can result in death  serious injuries or property damage     AN Attention     Designates a potentially occurring hazardous situation  Not observing these labels can result  in injuries or property damage      i   Instruction     Application instructions for the optimum use of the equipment and other useful information        04 2014 KARL KLEIN Ventilatorenbau GmbH Page 6    Operating manual for radial blowers for areas subject to gas and dust explosion hazards       1 Preliminary       1 4 Type plates and inst
8. d  USC ecsrrenancr conesite dhemcse deoceesectentenssoaees  estenceersteneests 8  2 1 Limitations to the use and special considerations for designated USES              eeeeeeee 8  2 2 Non designated USCS         ceceeeeeeeeeeeeeeeeeeeeeeeneeeeeeeeeaeeeeceaaeeesecaaeeeseeaaeeeeeeaaeeeseeaaeeesnenaeeeeeeaaes 8  3 SAPCCY svc cee E a E A E E 9  3 1 Basic safety inStrUctions sesca EANA RA aA 9  3 2  EMISSIONS wcdisiis odcdexietcedivs anatexcecertanss cncdeses daa a ea aaa ap eaaa AA da Eaa aeaaaee EN 10  Bele dl DIE E A A E A 10  e a EN oE T A T 10  31 3    VIDFALIONS inina oteaan ahaaa iaaa e aaa aap e EELA E aaia eaa Ee aaa 10  3 2 Overheating protection          ceccceccseceeseeceeeeeeeeeeeeeeeceeeeecaaeeeeaaesseneecaaeeesaaeseeaeesneeescaeeseaeenenees 10  4 Transportation and storage           seeccccsseeeceesseeeeeenseeeeeenseeeeeensneeeeenseeeeeenseeeeenseeeeeenseeeeeenses 11  5 DGSCHIPUON es eee ented ee en ee ae eee 12  6 Assembl y installation          cccceecccceeseeeeeeeneeeeeseeeeeeeseeeeenseeeeeenseeeeeeseeeeenseeeeeseseeeeeenseenenenees 13  6 1 General safety instructions for assembly and operation               ccccceeeeeeeeeeeeeeeeeeeeeeseeeeeeees 13  6 2 Hook Up IMStAllAUOM   52 3 senedececchiaed E apeaneseaeedenas sees eeceer ie seeaaeeees 14  6 3 Assembly and installation specifications for explosive areas              cccccecseseeceeeeeeeeeeseaees 14  6 4 Power MI OUNMING esse E es neared spedaerts 15  7 Maintenance  care and repair iNStrUuCtiONS           ces
9. e environment     All blower components must be properly disposed of in compliance with the national and  international laws and regulations        04 2014 KARL KLEIN Ventilatorenbau GmbH Page 17    
10. eeccceseeeeeseeeeeeeseeneeseseeneeseseeneeeeneenenens 16  7 1 Maintenance and Care esmerar ir ERAAN 16  7 2 Inspect and exchange bearingS       esssessrsesssrresssrnestrrnesrsnnestennnstnnnnntennnannnnnnnannannnnnnnnannannnna 16  7 3 Repair instructions and procedures             ecccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseneeeeeseneeeeeeeeeeeees 16  8 Additional steps to be taken when deploying blowers in Zone 21                sseeeeeeees 17  8 1 Vibration threshold values          ceeececeeeeeneeeeeenneeeeeeaeeeeeeaaeeeseeaaeeeseeaaeeeseeaaeeeseeaaeeeseenaeeeesenaes 17  9 DISPOSA aA AEA 17       04 2014 KARL KLEIN Ventilatorenbau GmbH Page 2    Operating manual for radial blowers for areas subject to gas and dust explosion hazards           i   Comply with safety instructions     Please read all safety instructions contained in this operating manual with care     Familiarize yourself with the operation of the blower before placing it into service  It will be  too late to do so when doing the work     Never permit someone without the proper technical knowledge to install and operate this  blower     Applicability  This operating manual applies to all blowers with the following model designations      x  ENG     Il 3 GD c  IIB or IIC  T125  C  DNG     Il 3 GD c  IIB or IIC  T125  C    EMV     ll 3 GD c  IIB or IIC  T125  C  DMV     Il 3 GD c  IIB or IIC  T125  C   EMVL     II 3 GD c  IIB or IIC  T125  C  DMVL     II 3 GD c  IIB or IIC  T125  C   DSV2     II  2 or 3  GD c 
11. g entity  As the operating entity  you are responsible for     e the correct technical and designated use of the blower by trained personnel     e compliance with safety regulations and safety instructions and any occupational safety  and accident prevention measures     e the technical training of the operating personnel on the equipment  and for their  awareness of the operating manual     e preventing hazardous dust deposits and or the timely cleaning of the motor surfaces     1 2 Operating entity obligations for blowers located in explosive  atmospheres    The Operational Safety Directive  BetrSichV or equivalent other national regulations  and the  11th Directive to the Machinery and Product Safety Act  11th GPSGV  require the operating  entity to make a variety of provisions for the use of machinery in explosive atmospheres     Pursuant to   3 of the Operational Safety Directive  BetrSichV or equivalent other national  regulations   the operating entity is required to conduct a hazard assessment of the area  where the machinery is to be used  This assessment is intended to recognize and to take  into consideration hazards that may arise when using the machinery in combination with the  production materials and the environment     Pursuant to   4 Operational Safety Directive  BetrSichV or equivalent other national  regulations   the operating entity is responsible for taking any required steps and for  selecting the equipment that is suited for the conditions at the depl
12. ith the circuit diagram  A correct hook up ensures trouble free  operation      i   Instruction     Connecting and control cables must be installed to EMV standards in accordance with  operating requirements and the respective local regulations     6 3 Assembly and installation specifications for explosive areas     Additional mandatory requirements      i   Instruction     The blower may only be mounted at one location  Either at the exhaust flange  the blower  base and or motor console or at the intake mounting flange      i   Instruction     The operating entity must install a suitable motor cut off switch   The minimum specifications for this  nominal current and te period  is shown on the type plate     AN Attention     During installation  body parts are subject to a crushing hazard between the blower and the  surroundings     e Ifthe blower is operated with an open intake  the surrounding area must be free of  ingestible objects     e Minimum distance between a wall and the cooling blower enclosure is 20 mm    e The motor breaker or motor cut off switch must correspond to the nominal motor rating  shown on the motor specification  type plate         04 2014 KARL KLEIN Ventilatorenbau GmbH Page 14    Operating manual for radial blowers for areas subject to gas and dust explosion hazards       KLEIN 6 Assembly installation       6 4 Blower mounting    A Attention  Potential for damage to the equipment   A double sided mounting must be avoided  This can result in damage a
13. nd failure of blower  components   Decouple the structure bound sound by installing a canvas expansion sleeve     The blower may only be mounted using one location  Either at the exhaust flange  the blower  base and or motor console or at the intake mounting flange     Installation examples         at the motor console    005_KL01_01    At the intake mounting flange for wall installation       04 2014 KARL KLEIN Ventilatorenbau GmbH Page 15    Operating manual for radial blowers for areas subject to gas and dust explosion hazards    7 Maintenance  care and repair instructions          7 Maintenance  care and repair instructions     i   Instruction     Depending on the intended use of the blower and the respective system concept  the  operating entity may consider additional cleaning and or maintenance intervals     Unauthorized repair of damage or exchange of components are hazardous  This renders the  explosion protection features ineffective     7 1 Maintenance and care    e When using condensation water drainage holes  or when the equipment is deployed in  locations with dew buildup  causing condensation water to collect in the motor s interior   the collected condensation water must be drained in regular intervals via the  condensation water drainage opening at the lowest point of the bearing enclosure  the  drainage opening must be subsequently resealed     e The dust buildup on the equipment surface must not exceed a thickness of 5mm     e The blower wheel must be regul
14. oyment location and that  will ensure safety and health protection if used as designated     To do so  the operating entity may refer to our KLEIN catalog  which contains detailed  technical specifications and notes regarding uses     When conducting the hazard assessment and selecting a suitable machine  the operating  entity must apply directive 2006 42 EC  of the European Parliament and the Operational  Safety Commission and directive 94 9 EC  dated 23 March 1994  also known as the ATEX  directive  and the applicable harmonized standards  EN   for instance EN 14986  Designs for  blowers for the use in explosive atmospheres or EN 1127 1  Explosive Atmospheres     the operating entity is solely responsible select the equipment  blower  suitable for the  intended area and the intended location     Repair and or service work on explosion protected blowers may only be performed by the  manufacturer or by a repair shop authorized to do so  After the work on the blowers is  completed  the dust explosion protection must have been returned to operational status        04 2014 KARL KLEIN Ventilatorenbau GmbH Page 4    Operating manual for radial blowers for areas subject to gas and dust explosion hazards    1 Preliminary          Product Warranty    KARL KLEIN Ventilatorenbau GmbH provides a product warranty as part of its general terms  and conditions of sale and delivery     The warranty is rendered null and void if the installation and operating procedures described  in this oper
15. r assembly and operation    AN Warning  Life threatening electrical shock hazard     A life threatening electrical shock hazard exists if the blower cable ends are connected  without first disconnecting the electrical power    Always disconnect power prior to working on components that are electrically  energized     e Correspondingly  the electrical hook up may only be performed by a qualified and  trained electrician who is trained in installation procedures in explosive environments     e Trained electricians are persons who are familiar with the assembly  installation  initial  startup and operation of the equipment machine and possess an appropriate  qualification  or who are familiar with safety technology standards in the maintenance  and use of appropriate protective gear and accident prevention procedures as a result of  a corresponding education or training     e The installation depends on the requirements placed on the blower and the function  specific conditions at the installation location  on the machine or the equipment      e Only use spark free tools when performing assembly and installation work in explosive  environments        04 2014 KARL KLEIN Ventilatorenbau GmbH Page 13    Operating manual for radial blowers for areas subject to gas and dust explosion hazards       6 Assembly installation       6 2 Hook up  installation     i   Instruction     The terminal assignments on the terminal block can be found in the terminal box  It is  mandatory to comply w
16. rdous condition     3 Safety    3 1 Basic safety instructions    Klein blowers are designed and produced in accordance with generally accepted technology   occupational and accident prevention practices and in accordance with the requirements of  the directive 94 9 EC for machines and protective systems for the designated use in  explosive environments  as well as the requirements of the Machine and Product Safety Act   GPSG or equivalent other national regulations   They correspond to the state of the art     Nevertheless  blowers in operation can be the source of hazardous conditions  especially  when hazardous conditions are created as a result of    e inappropriate use or    e non designated use    For this reason  all instructions for the use of the blower must be adhered to      i   Instruction     e The blower may only be placed into operation when in impeccable overall condition   only with an undamaged housing and impeller wheel  and only with a fully operational   safe electrical hook up  Operating a defective machine is a danger to life and limb     e Easily ingested materials  such Styrofoam  fabric rags  or similar may not be located in  the vicinity of the intake  Care must be taken that sufficient clearance is provided to the  intake     e Take note of the air exhaust direction and area  The fragments from an impeller wheel  failure must be prevented from damaging the downstream equipment to be cooled     e The electrical installation must correspond to the req
17. ruction labels     i   Instruction     The specifications on the type plate are important for the designated use   All labels and plates must be legible at all times  Illegible or lost type plates and  warning labels must be replaced immediately        Isol  Kl              S  A          an  cos                         WY Karl Klein Ventilatorenbau GmbH C      D   73773 Aichwald    DNG 6 35      Il 2 Dc T3  IB 03 1 992          KLEIN       P N  81529 1 040 S N  0309 11111  S N Motor   50 Hz 1760 m  h 780 Pa             GGD    The information on the type plates identifies the respectively desired blower type and rating   The information on the type plate corresponds to the performance ratings that were ordered   These may be subject to change      il Instruction     The values shown on the type plate take precedence   Other performance ratings are found in the order confirmation       04 2014 KARL KLEIN Ventilatorenbau GmbH Page 7    Operating manual for radial blowers for areas subject to gas and dust explosion hazards    2 Designated Use          2 Designated use     i   Instruction     For instance  the blower may be labeled as II 2 GD c IIB T4  Equipment class Il  Category 2  D   Dust  G   Gas  c   design safety  IIB   explosion subgroup according CENELEC   IEC   NEC 505   T3   up to 200   C surface temperature   T4   up to 135   C surface temperature    The blower can be used in atmospheres subject to dust and gas explosion hazards for  zones 1 and 2  21 and 22  in accord
18. sport the equipment with suitable rigging and lifting implements  Prevent the blower  from tipping     The lifting eyes on the blower housing are not intended as the sole means of lifting the entire  blower  The motor must always be secured separately     AN Attention     During transport  body parts are subject to a crushing hazard between the blower and the  surroundings      il Instruction     Dispose of packaging materials properly  Do not burn them      i   Storage instructions     Before transporting the blower to the installation site  the equipment should only be stored in  enclosed  dry areas   Storage in open spaces that are protected by roofing is permitted for only short periods     The blower must be protected against damaging environmental influences and mechanical  damage        04 2014 KARL KLEIN Ventilatorenbau GmbH Page 11    SA Operating manual for radial blowers for areas subject to gas and dust explosion hazards    KLEIN 5 Description       5 Description  Standard configuration  KLEIN blowers are radial blowers with a ball bearing mounted electrical drive     The respective medium is ingested axially and exhausted radially in the desired direction   see illustration                        Flow direction of the medium       04 2014 KARL KLEIN Ventilatorenbau GmbH Page 12    Operating manual for radial blowers for areas subject to gas and dust explosion hazards    6 Assembly installation          6 Assembly installation    6 1 General safety instructions fo
19. ts  Use a filter as  needed  see KLEIN list of accessories     e When conveying aggressive media  the blower corrosion protection mechanisms must  first be adapted to the material characteristics   Consult the manufacturer     e  f the blower is to be used in an open blowing configuration  or if it is likely that a hazard  exists for the downstream machine or installation if the blower wheel breaks  a  protective screen must be mounted to the blower exhaust opening    e The blower may only be operated in an installed condition  i e  mounted to or into  systems and machines    e The temperature of the entering conveyed medium may not exceed  60   C    e The ambient temperature may not be below     20   C or exceed   40   C    e The blower may only be operated with an installed intake protective screen     2 2 Non designated uses    Non designated and hazardous uses specifically include    e conveying of explosive or combustible media in zone 20 and zone 0  the blower may  only be used in zones 1  21 and 2  22 with a corresponding marking on the type plate    e conveying abrasive media    e conveying without a suitable intake protective screen     04 2014 KARL KLEIN Ventilatorenbau GmbH Page 8       Operating manual for radial blowers for areas subject to gas and dust explosion hazards  3 Safety          e operation without a motor cut off switch    e use in underground mining operations    e any other use that deviates from the designated uses  and which will result in a  haza
20. uirements of the machine into  which the blowers are to be installed  i e  motor cut off switch      e The personnel must be familiar with all steps described in this operating manual that  relate to the proper operation and use of this equipment     e  n areas with dust build up and dust load in the environment  the dust deposits must be  held low enough to prevent the dust smoldering temperature from being reached     e Explosion protected blowers may not be repaired by the customer  To maintain the  explosion protection  blowers may only be repaired or maintained for preventive  purposes by the manufacturer     e To avoid combustion hazards from dust deposits  cleaning intervals must be rigorously  complied with  The cleaning operation must be performed with diligence     e The dust buildup must not exceed a thickness of 5mm        04 2014 KARL KLEIN Ventilatorenbau GmbH Page 9    Operating manual for radial blowers for areas subject to gas and dust explosion hazards  3 Safety       KLEIN       3 2  Emissions    3 1 1 Dust    The incidence of hazardous emissions is dependent on the various media to be conveyed    3 1 2 Noise    The noise profile depends on the installation type  on the environmental conditions and the  respective operating load on the blower    The operating noise levels of the blower can reach high levels for certain installation types  and usages  The values can range from 60 to 110 dB  A   Detailed acoustic pressure levels  can be found in the KLEIN cat
    