Operating Instructions DIGITAL COUNTER VEK CN1
Contents
1. FrEE Cancel changes Skor Output status saved MAGNETIC UTOCONTROL 1 3 3 Display and Counter reset The Inputs can individually count to up to 9 999 999 and can individually be displayed or if necessary reset to zero Display Status Setting 1234 Normal Operation 2xshort Cnk1 Input counter 1 5xshort Cnk4 Input counter 4 Cnk1 4 Display current count 1234 0 9999 Alternating next next menu Cnk1 4 Display Input count Current Input count 1234 10 000 9 999 999 Start the input counter reset 456 Continuously 0 flashing gt Skor Reset Input counter Cancel reset Note 1 The open space or quantity of passed vehicles count will not be effected during reset of any of the input counts 3 If one of the four 4 input counter display is activated the display will not switch back to normal operating display by itself 1 3 4 Reset all counters The open space and passed vehicle counter as well as the four 4 input counters can be reset at ones using following menu Display Status Setting 1234 Normal Operation 6 x short gt rES Reset menu Reset Menu long reset all counters short back to normal operation without reset The output relay setting manually FREE and manually OCCUPIED is not effected by this reset TIT MAGNETIC UTOCONTROL 1 4 System menu Installation specific Settings In the system menu all i
2. End back to normal operation Alternating Change Threshold Change Threshold gt Digit 1 0 9999 1sec Fast scroll 3 sec gt 10 s gt 100 s gt 1000 s gt 100 s gt 10 s gt 1 s Cancel Skor save 1 4 1 1 Operating Mode OPEN SPACE COUNT The OPEN SPACE COUNT is preferably used when the control audit count of the parking spaces is done when the car park is full so less open spaces has to be counted Vehicles leaving the car park will increment the count Input 1 and vehicles entering the facility will decrement the count Input 2 The counter will activate the output relay whenever the open space count is equal or less than 0 The output relay will be released as soon the count reached the adjusted count hysteresis 1 4 1 2 Operating Mode PASSING VEHICLE COUNT The PASSING VEHICLE COUNT is preferably used when the control audit count of the parking spaces is done when the car park is empty so less occupied parking spaces must be counted Vehicles entering the car park will increment the count Input 1 and vehicles leaving the facility will decrement the count Input 2 The counter will activate the output relay whenever the vehicle count reaches or is higher than the adjusted maximum The output relay will be released as soon the count reaches or is lower than the adjusted lower count hysteresis 1 4 2 Count Hysteresis With the cou
3. normal operation Fr on e If full NC A Or M Change function oc on Fr on Change relay function W Fr on gt oc on oc on v gt oc on gt Fr on Flashing iM short Cancel M long gt Skor save Factory default is Normally Open mode for the output relay 11 11 1 4 6 Power Save Mode If the Power Save Mode is activated the display turns if there was no activity on the user interface for more then 30sec The count function continuous to run in the background The Power Save Mode can be adjusted using following menu MAGNETIC UTOCONTROL Display Status Setting 1234 Normal Operation M long gt SuS gt S oc MI 9 x short LoPo Power Save Mode LoPo Display Power Save MI short next next menu item Alternating Mode IMI long End return to normal operation Off e OFF Display On A Or M Change Function On e ON Display Off Off Change Function W gt off gt on On V gt on off Flashing M short Cancel M long Skor Save 1 4 7 Setting the Serial Interface optional Currently not available 1 5 Factory Default All parameter and counter can be reset to factory default using following procedure Display Status Setting Turn off power to the unit for longer then 2 seconds 1234 Flashing Err Flashing Return after power failure Press two buttons simultaneously gt Err System error M long Skor
4. 999 999 for statistical use independently displayed Available Open space counter and count hysteresis are adjustable Upper and lower counter threshold is adjustable 3 push buttons for user interface Power Supply 12 24V DC oder AC No loss of current data storage in case of power failure Alarm display when power is was lost Optional RS485 Interface for data polling setup or direct communication with a traffic sign Compact Plastic housing 0 88 22 5mm x 3 15 80mm x 3 35 85mm with DIN Rail mount MAGNETIC UTOCONTROL 1 2 Display and Setup 1 2 1 User interface buttons The VEK CN1 digital counter is adjusted with the three 3 user interface buttons located on top of the unit The display shows the current menu and status of the setup The buttons have following functionality Button Function Short Next Menu next digit Cancel settings Mode Long Activate System menu Save changes exit menu A Short Display value increments 1 UP Long Display value fast increments Display value increments 1 DOWN Long Display value fast decrements Two simultaneously Cancel changes back to operating mode The menu is divided in base menu and system menu During setup the flashing display signalizes that the settings aren t saved yet If the unit was idle for 30sec the unit goes back to normal operating mode without saving the changes 1 2 2 Power Failure During loss of powe
5. Reset to factory default 0000 flashing factory default M short Cancel Restart without factory default settings After the reset to factory default all parameters are set to the following see table below and all counters are set to zero 0 Parameter Setting Ouk Relay output Auko Automatic S oc Switch Point 0 0 Open Space Count HyS Count hysteresis 1 one vehicle SkP Upper count level 9999 SkP__ Lower count level 999 InP1 Function Input 1 incrementing InP2 Function Input 2 decrementing InP3 Function Input 3 incrementing InP4 Function Input 4 decrementing rEL Output functionality Normally Open Mode LoPo Power Save Mode aus Anzeige immer aktiv MAGNETIC UTOCONTROL 2 Installation Instructions 2 1 Input voltage All inputs are provided with Opto couplers To activate the inputs you can either use the internal switching voltage or use an external supply When using an external supply you must first change the internal jumper setting of the control board To do so carefully open the controller housing and set the jumper J2 in accordance with the drawing and table below Attention The control board consists of electrostatic sensitive components If working on the control boards please use electrostatic save measurements to prevent any damage to the components Do not touch the bo
6. ard or any of the components alternativ alternativ A J either Or y A R e 5 mA at 12V esk K o ye l 10mA at 24V C R11 14 12 24V DC C R11 14 epee eE Internal supply is does not use the External supply uses the Opto couplers Opto couplers Power Supply Input power Attention 12 24V DC Internal e ONLY ONE POWER SUPPLY FOR ALL COUNTERS Jumper J2 to the left e DO NOT CONNECT TERMINAL C THE INPUTS ARE CONNECTED TO GROUND OV 12 24V AC Internal DO NOT CONNECT MULTIPLE COUNTERS IN PARALLEL Jumper J2 to the left 12 24V AC oder DC External 12 24V DC USE ONLY ONE EXTERNAL POWER SUPPLY FOR ALL Jumper J2 to the right INPUTS 13 13 MAGNETIC UTOCONTROL 2 2 Reset Input optional Using one of the inputs as count reset input all counts can be reset to 0 when a signal is applied According to the relay output setting the relay switches to OPEN or OCCUPIED The reset does not effect the adjusted parameters MAGNETIC UTOCONTROL 3 Technical Data Measurements 3 79mm x3 4 22 5mm x3 50 90 mm HxWxL without Plug Protection Class IP 40 Power Supply 12V to 24V AC DC 10 Power Consumption max 2 W Operating Temperature 20 C to 70 C Storage Temperature 40 C to 70 C Humidity max 95 non condensing Count Total 999 bis 9 999 Per count input up to 9 999 9999 Inputs Opto Coupled 4 Inputs Min
7. imum input time 50ms Input current 5mA at 12V 10mA at 24V Relay Output Form C Isolation Basisisolierung f r 230V Sicherheits und Warnhinweise beachten Max Current Rating AC 250V 4A 125VA DC 220V 2A 60W 0 25W 10mV 1mA Fuse none must be external 15 15
8. ma NETIC a eal Operating Instructions DIGITAL COUNTER VEK CN1 Version 2002_03 1 1 m ETIC So NOTE COPYRIGHT 2001 Magnetic Automation Corp All rights reserved No part of this publication may be reproduced transmitted transcribed stored ina retrieval system or translated into any longuage in any form by any means without the written permission of Magnetic Automation Corp First Printing 2001 The manufacturer reserves the right to modify without prior notice the technical specifications in order to accommodate the latest technical developments Magnetic Automation Corp will provide information on the status of existing operating instructions and on any alterations and extensions that may be relevant Please read these operation instructions prior to installing the equipment Table of Contents 1 Functional Description 1 1 General 1 2 Display and Setup 1 2 1 1 2 2 1 2 3 User interface buttons Power Failure Display during normal operation 1 3 Base menu Setting the operating modes 1 4 System menu Installation specific Settings 1 2 2 1 1 3 1 1 3 2 1 3 3 1 3 4 1 4 1 1 4 2 1 4 3 1 4 4 1 4 5 1 4 6 1 4 7 Modify Correct current count Set Relay Output manually to Free or Occupied Display and Counter reset Reset all counters Operating Modes Switching point Count Hysteresis Upper Count Level and lower Count Level Display Input
9. nstallation specific settings can be made Display 1234 Menu Item Normal Operation Setting M long gt Display SYS System menu Alternating shows program version for example A02 S oc 1234 Alternating HYS 1234 Alternating SkP 1234 Alternating SkP_ 123 Alternating Switch threshold 0 9999 Count hysteresis 1 250 Upper Count threshold 0 9999 Lower Count threshold 0 999 inP1 4 Alternating Add Sub rEs no F rEL Alternating oc on Fr on LoPo Alternating off Input functions e Increment count e Decrement count e Reset count e No function Output function e Normally closed e Normally open Power Save Mode e off Display an an Display aus on Pork Serial Interface short next menu item i or M change long save Two buttons simultaneously M long End back in normal operation MAGNETIC UTOCONTROL 1 4 1 Operating Modes Switching point The digital counter can be set to Operating Mode OPEN SPACE COUNT or PASSING VEHICLE COUNT The two options can be selected by setting the Count threshold to Threshold 0 Default Mode OPEN SPACE COUNT see 1 4 1 1 Threshold 1 1 9999 Mode PASSING VEHICLE COUNT see 1 4 1 2 Status Setting Normal Operation long SuS gt S oc Threshold S oc Display next next Menu item 1234 Count Threshold
10. nt hysteresis you can set the amount of vehicles that have to leave the facility after the OPEN SPACE COUNT or the PASSING VEHICLE COUNT have reached the maximum and triggered the output relay Factory default is 1 Display Status Setting 1234 Normal Operation M long gt SuS gt S oc M 1 x short gt HyS Count hysteresis HYS Display MI short next next menu item 1234 Count hysteresis M long End return to normal operation Alternating A Or M Change Count hysteresis 1234 Change Count W Or M gt digit 1 One flashing hysteresis A Or M 1 sec fast scroll digit 1 9999 A Or M 3 sec gt 10 s gt 100 s gt 1000 s M short gt 100 s gt 10 s gt 1 s gt cancel Ml long gt Skor save 9 9 MAGNETIC UTOCONTROL 1 4 3 Upper Count Level and lower Count Level The maximum and minimum range of the total count can be adjusted using this menu This enables the counter to automatically adjust the total in case the maximum or minimum level is reached to prevent a wrongful count to continue The default is 9999 for the upper and 999 for the lover level Display Status Setting 1234 Normal Operation SkP _ Display 1234 Count level Alternating 1234 Change Count Level One flashing digit 0 9999 M M M M long gt SHS gt S oc 2 x short gt SkP upper level 0 9999 gt SkP_ lover le
11. ontains all settings for the different operating modes The existing counts can be displayed modified and reset to original stage The relay output can manually be set to FREE or OCCUPIED Display Menu sdSetting o 1234 Normal Operation Current Count res Reset all Coumes MI Short next next menu item Two buttons simultaneously or long End back to normal operation Al or v change long save 1 3 1 Modify Correct current count Display 1234 Normal Operation W or M First digit flashing gt modify counter 1234 One digit flashing Modify Counter gt Digit 1 Fast scroll gt 10 s gt 100 s gt 100 s gt 10 s Skor saved gt 1000 s gt 1 s gt Cancel 1 3 2 Set Relay Output manually to Free or Occupied If for any reasons the relay output needs to be disabled the output can manually be set to maintain either the always FREE or always OCCUPIED status Display Status Setting 1234 Normal Operation M 1 x short gt Ouk Output status display Ouk Output Status Display Auko e Automatic occu e Occupied Free FrEE Alternating next next menu item End back to normal operation Select output status Auko Selected Output status occu FrEE blinkend FrEE Auko occu soccu Auko
12. r the current count values and setup are saved When the power returns the unit goes back in normal operating mode but signalizes with the flashing display that there was a loss of power and the open space count must be checked and if necessary updated Display 1234 Return after loss of or Update open space count Flashing power Confirm existing count is correct 1 2 3 Display during normal operation In normal operating mode you can have the display show either how many vehicles entered the car park or how many open spaces are left see 1 4 1O0perating Mode Switching point The relay status is displayed with the LED Light The input status are displayed with 4 dots Special statuses are directly displayed Display Status displa Current count Output manually set to free display 0000 Reset Input active Optional Input Status left to right 1 2 3 4 LED on off Output relay status activated on deactivated off Display off if unit was idle for Power save mode 30sec Note 1 If one of the four 4 input counter display is activated the display will not switch back to normal operating display by itself 2 If the Power save mode is activated the display will turn off when the unit was idle for more than 30 sec By pressing the M Button the display can be turned on again see 1 4 6 Power Save Mode 5 5 MAGNETIC UTOCONTROL 1 3 Base menu Setting the operating modes The base menu c
13. settings Output settings Power Save Mode Setting the Serial Interface optional 5 Factory Default Installation Instructions Input voltage 2 2 Reset Input optional 3 Technical Data 3 3 ma NETIC a eal OOM NVNDDOD nnn A A MAGNETIC UTOCONTROL 1 Functional Description 1 1 General 4 pin plug for counting inputs ov zav C Optional 4 pin plug for RS485 Interface The digital counter VEK CN1 is designed to control small to medium car parks Four 4 counting inputs are used to accept outputs from loop detectors and or traffic gate controllers The counting inputs increment or decrement the count and is displayed on the 4 digit display The output relay is used to turn on off traffic signs or lot full signs Available Open space counter and count hysteresis are adjustable The output relay can be used to directly control a traffic light or a lot full sign Characteristics Digital counter is specifically developed for small to medium car parks Vehicle count and open space count 4 digit display Totalize counter 999 bis 9999 4 noise immunity inputs each function Reset individually adjustable 1 Reset input optional 1 Relay output 250V 5A for Traffic lights and Lot Full signs or others Output is adjustable for automatic permanent free permanent occupied Relay is adjustable to Normally Open or Normally closed mode LED to display relay status 4 independent input counters up to 9
14. vel 999 0 next next menu item End return to normal operation Change count level gt Digit 1 fast scroll gt 10 s gt 100 s gt 1000 s gt 100 s gt 10 s gt 1 s gt Cancel Skor save MAGNETIC UTOCONTROL 1 4 4 Display Input settings Independent from each other the inputs can be set to e Incrementing e Decrementing e Reset Count e No function Display Status Setting 1234 Normal Operation MI long SuS gt S oc M 4 x short gt InP1 Function Input 1 inP1 4 Display Input function M short next Input next menu item Alternating 1to4 M long End return to normal operation Add e Incrementing Wor V gt Change function Sub e Decrementing rEs e Reset count no F e No function Add Change Function IN gt no F gt rEs gt Sub gt Add Sub M Add Sub gt rEs gt no F rEs iM short Cancel no F MI long Skor save Flashing Factory default is Incrementing for Input 1 and 3 and decrementing for Input 2 and 4 1 4 5 Output settings The output relay can be adjusted to Normally Open NO or Normally Closed NC Display Status Setting 1234 Normal operation M Short gt SuS gt S oc Mi 8 x short gt rEL Relay function rEL Display Relay function M short next next Menu item Alternating If free NC M long End return to
Download Pdf Manuals
Related Search
Related Contents
Project Guideline in pdf Contrôleur ValveMate™ 8000 Vytec Final Dell Vostro 3360 Manual do Proprietário Atlas Sound CS95-8 User's Manual JVC CA-UXF4VB User's Manual Heidelberg CD51 d. MS3834U100YR6ユーザケーブル 取り扱い説明書 SC-920 MAUAL DE INSTRUCCIONES (ESPANOL) 0753 MkII Es_Mar 11 Copyright © All rights reserved.