Home

Operating instructions - OPERTIS Produktkatalog

image

Contents

1. Detailed information on this is given in the eLOCK system documentation software Active extension of the fitting opening time lf an authorised identifier is held in front of the wall scanner for longer than the defined fitting opening time the wall scanner or the connected peripheral device remains activated until the authorised identifier is removed Acoustic and visual signals The acoustic and visual signals of the connected wall scanner antenna depends on the programming The programmed fittings in the AddDelete system and the fittings programmed using eLOCK Center have a different signalling concept Note The complete visual and acoustic signals are included in the eLOCK system documentation Signalling Concept section 10 OPERTIS 07 2013 eLOCK GB Operating instructions Wall scanner controls ES641x ES642x ES641x ES742x The wall scanner antenna emits acoustic and visual signals for certain system states and events Visual signal Acoustic signal Meaning red flashing Wall scanner ready for use 2x short blue blue 1xX ascending sound Programming mode on sequence blue flashing Programming mode active 1x descending sound End of programming sequence mode automatic 2x short green 1x short high pitch Wall scanner connection green by authorised identifier 2x short red red 1x long low pitch No wall scanner connection identifier not authorised 2x red green 1x short high pitch Wall scanner connection i
2. OPERTIS Operating instructions Wall scanner controls ES641x ES642x ES741x ES742x eLOCK GB Operating instructions Wall scanner controls ES641x ES642x ES641x ES742x Contents 1 513 ol B e1 Lo serrian aAA Anana a RER BEE ERE NR EEAERMAREEEEEORR 4 PDOUU INES SINS ERUCUIOINS a 4 Explanation of the Symbols and Signal Words Used c ccccceccceeeceeeeeeeeeeeeeeeeeeees 4 Erge GLOUP ee see 4 OPERU 0 6 8 0 9 eee es ene nnn n ee ee 4 Up to date status of the INfOrmatiOn cccccccecceecceeeeeeceeeeeeeeeeeeeceeesseeeeeeeeeeeeneeeeeees 5 2 Product Description une eh 6 BIS gh Ogee CAR Ce EISEN Cee IOS NER TER MEE SERIEN TEL NEEFERRENERERRER SER EME EE VERT ee eT ee 6 VAL UU ONS aia ee E A es cele asemeduedeaasest 6 FUNELIONal BEINEIPleErs nee ee ee een T Detaled ANONA NO eearri aea 7 3 lntended US ssis nee 8 TAN iets bal ON ee en ee ee eae eee eo ee 8 Condition of the FOO LICE ee 8 AIMIDICIU CONG ONS ee euere 8 Res IAUaLlISsKase nenne resp 8 A SafelY Insiruclions za ae ae 9 5 Use and Operation n a ann naeh wanna ehe Denn wen 10 Programming fittings and identifiers 02220222022000200000000n0 Bono anne nano nano nnne nee nnnenn 10 Active extension of the fitting opening time u022002200220nnnnnnnnnenenenenenenenenenn 10 ACOUSIC ANG VISsUAl S19Nalsa ae ie 10 6 Servicing Cleaning and Maintenance uuusnsanunnnnnunnnnnunnnnnnnnn
3. on a mounting rail in a switch cabinet Condition of the product Wall scanner controls may only be used if they are in a technically perfect condition Independent modifications and changes to the product are not allowed Ambient conditions Use of the wall scanner controls in a particularly polluted environment e g in aggressive gases or in extreme temperatures is not allowed If you have any questions please contact OPERTIS Support Residual risk If used properly and if the maintenance instructions are followed this product will support your property security However the following residual risks cannot be excluded O Inthe event of failure of the mains power supply there is a risk of locking in or out In this case the door can only be opened with mechanical aids O In the event of failure of the electronics there is a risk of locking in or out The door can then only be opened with mechanical aids In this case contact OPERTIS Support O Ifa wall scanner is used to control access to a fuse box and a fuse is defective there is risk of locking in or out The door can then only be opened with mechanical aids O OPERTIS recommends use of an uninterruptible power supply UPS to ensure operation of the wall scanner controls during a power failure 8 OPERTIS 07 2013 eLOCK GB Operating instructions Wall scanner controls ES641x ES642x ES641x ES742x 4 Safety Instructions 07 2013 The following safety instru
4. Standard wall Activation of the internal or scanner external relay for control of control peripheral devices by holding an ES641x authorised identifier in front of the ES 41x antenna The wall scanner control is controlled Multi relay _ Activation of the internal or by the eLOCK Center wall scanner external relay for control of management control peripheral devices by holding an SOftware see eLOCK ES642x authorised identifier in front of the System software The wall scanner control up to 100 additional relays an external PCS system for 4 350 identifiers taught directly in the wall scanner control Standard Activation of the internal or The wall scanner AddDelete external relay for control of control is controlled wall scanner peripheral devices by holding an by special control authorised identifier in front of the programming ITs ES741xxEL antenna see AddDelete operating instructions 6 OPERTIS 07 2013 eLOCK GB Operating instructions Wall scanner controls ES641x ES642x ES641x ES742x Functional principle The OPERTIS eLOCK lock system ensures continuous public and commercial building fitout Special fitting solutions are available for different door types The wall scanner controls can be combined with different OPERTIS masking caps and housings and operated with an external power supply In addition external antennas can be connected Interfaces are available for controlling external relays
5. or peripheral devices and for networking via LAN modules The multi relay wall scanner controls control peripheral devices via a connected PCS system Management and programming of the fittings among other things the issue of access authorisations takes place using the eLOCK Center management software Optionally programming with eLOCK AddDelete is also possible via three programming keys without additional software Passive identifiers without their own power supply are available for authorisation at the fittings in the eLOCK lock system in different forms such as keys key fobs cards or customer specific forms These must be held on the wall scanner antenna for an authorisation check Detailed information 07 2013 Further information on the product is given in Section 8 Product Specifications OPERTIS 7 GB eLOCK Wall scanner controls ES641x ES642x ES641x ES742x Operating instructions 3 Intended Use Area of use The wall scanner controls within an eLOCK lock system are designed to control peripheral devices for example electric door openers electric locks motorised bolts holding magnets electrical door and gate drives barrier systems lifts mailboxes etc The wall scanner controls are suitable for installation in the protected internal area The flush mounted versions are installed in flush mounted boxes or on the surface with special spacer frames The mounting rail version is intended for installation e g
6. al identifier in front of the device opens for the duration connected antenna s of the Of the defined opening time wall scanner control The wall scanner antenna signals as specified see section Active extension of the fitting opening time 2 Read fitting info check time If necessary reset time and and date see eLOCK system date see eLOCK system documentation documentation software 12 OPERTIS 07 2013 eLOCK GB Operating instructions Wall scanner controls ES641x ES642x ES641x ES742x 7 Problems and Solutions Note Problems which can occur in or due to connected components e g external antennas and the solutions are described in the respective installation instructions Problem Possible cause Solution Identifier is not Identifier is defective Replace identifier recognised no E er an Eve Wall scanner antenna is Replace wall scanner p J defective control acknowledgement Identification attempt made at wall scanner control without internal wall scanner antenna Identifier is not given Identifier is not Program identifier see access programmed or does eLOCK system not have the necessary documentation authorisations software Wall scanner time is Reset time see eLOCK incorrect system documentation Peripheral device Wall scanner control Replace wall scanner does not respond relay is defective control Peripheral device is off Switch on power supply load to the peripher
7. al device Peripheral device is Correct connection incorrectly connected Peripheral device is Replace peripheral defective device Connection conductors Replace connection or cables are defective conductors cables Mounting rail version Replace fuse Fuse is defective Peripheral device A fitting time profile was Change state of the remains activated removed from the wall _ fitting several options Relay remains picked scanner during the O Use switch key up fitting opening time O Program new fitting time profile O Perform switch function for online fittings via eLOCK Center 07 2013 OPERTIS 13 GB Wall scanner controls ES641x ES642x ES641x ES742x Problem Wall scanner antenna has no ready signal Mounting rail version Status LED of the wall scanner control is off Each identifier is authorised to lock 14 OPERTIS eLOCK Operating instructions Possible cause Solution Power supply is Ensure power supply defective or is not connected Ensure connection with antenna Connection cable to the antenna is defective or Is not connected Connect the correct power supply Operating voltage not within the allowable range Wall scanner control is defective Replace wall scanner control Wall scanner antenna is Replace wall scanner defective antenna Relay has already Wait for relay to drop picked up out Power supply is En
8. al of trouble free operation of the wall scanner controls and who has successfully completed suitable vocational training for these activities or has had the necessary appropriate experience OPERTIS Support If you have any questions extending beyond the information provided in these instructions please contact OPERTIS GmbH Prof Bier Stra e 1 5 D 34454 Bad Arolsen Tel 49 5691 87741 200 Fax 49 5691 87741 281 E Mail support opertis de 4 OPERTIS 07 2013 eLOCK GB Operating instructions Wall scanner controls ES641x ES642x ES641x ES742x Up to date status of the information All details on the product images dimensions and models correspond to the status at the time the product is delivered We reserve the right to make changes due to technical progress and the resulting continuous improvement process to which our products are subjected The current version of these instructions and further information is also available on our internet site www opertis de Dated 07 2013 07 2013 OPERTIS 5 GB eLOCK Wall scanner controls ES641x ES642x ES641x ES742x Operating instructions 2 Product Description Overview The following wall scanner controls are described in these instructions Art No Name Drawing ES64xxU ES7 4xxU Wall scanner control concealed underplaster flush mounted installation ES64xxT ES7 4xxT Wall scanner control mounting rail installation Variations Name Function Control
9. antennas Power supply connections Power supply Automatic recognition O 12 24 V DC non stabilised 10 or O 24V AC 10 The wall scanner control must be supplied from a power source with limited output according to EN 60950 1 2001 External antennas O A maximum of 6 external antennas can be connected to a wall scanner control without internal antenna O A maximum of 5 external antennas can be connected to a wall scanner control with internal antenna Power supply of the wall Operation of more than 3 antennas in scanner antennas total via one wall scanner control is only possible with an additional external power supply 9 V DC Length of the connection cable lt 300m series connection of external antennas Power consumption Depending on the number of connected antennas 1 connected antenna 1 W 2 connected antennas 1 6 W 3 connected antennas 2 2 W 16 OPERTIS 07 2013 eLOCK GB Operating instructions Wall scanner controls ES641x ES642x ES641x ES742x 07 2013 Interfaces O Connection for external antennas O Connection for control of a PCS system multi relay O Connection for an LAN module O Connection for controlling external relays Current input max 230 mA for 12VDC and with 3 connected antennas Outputs O 1 relay output Photomos NO make contact O Concealed flush mounted version Control of the external relay ES0532U with two electromechanical changeover contacts O Mou
10. ctions must be read and followed before use OPERTIS does not accept any liability whatsoever for personal losses or injuries or damage to property caused by failure to note and follow these instructions WARNING Risk of personal injuries and damage to property There is an increased risk of injuries if the wall scanner control or connection cables are touched while the power supply is switched on electric shock The wall scanner control or connected peripheral device can be irreparably damaged Carry out installation and maintenance work only if the power supply is switched off Note and observe the VDE Guidelines VDE 0100 CAUTION Risk of damage to property Electronic components can be irreparably damaged if touched Note and observe the regulations and notes in the DIN EN 61340 5 2 standard CAUTION Unauthorised access after installation When delivered the wall scanner controls are in construction site mode Access is possible with any OPERTIS identifier even if they are not programmed Program the authorisations immediately after installation to prevent unauthorised access see eLOCK system documentation software Check time and if necessary reset OPERTIS 9 GB eLOCK Wall scanner controls ES641x ES642x ES641x ES742x Operating instructions 5 Use and Operation Programming fittings and identifiers Fittings and identifiers are programmed using the eLOCK Center management centre or the eLOCK AddDelete system
11. n construction site mode or permanent release mode see eLOCK system documentation Fitting Modes section 2x short red red 1x long low pitch 4x System error 4 x yellow short low pitch Dismantle wall scanner contact ES Support Important information During communication between a wall scanner antenna and an identifier or the programming equipment e g programming mode signalling takes place at this wall scanner antenna only All other connected wall scanner antennas are inactive for this period 07 2013 OPERTIS 11 GB eLOCK Wall scanner controls ES641x ES642x ES641x ES742x Operating instructions 6 Servicing Cleaning and Maintenance The servicing cleaning and maintenance may be carried out by qualified personnel only Warranty cover is excluded for damage caused by improper handling Intervals Activity Interval Servicing 1 year Cleaning and maintenance Cleaning and maintenance of the wall scanner control is not necessary Servicing CAUTION Risk of locking in or out Peripheral devices cannot be controlled without a fully functional wall scanner control and antenna During the functional test of the wall scanner controls and antennas it is necessary to ensure that the systems controlled by the wall scanner control do not prevent anyone from passing through The following functional tests must be performed once a year Step Activity Result 1 Hold an authorised OPERTIS The connected peripher
12. nnunnnnnunnnnnnnnnnnen 12 NUS VOUS 22 2 ee er ee es u 12 leaning and malnlenance nasse 12 SEITE ING Er een ee een re 12 7 Problems and Solulions s essen eerheeeeehehe 13 8 Produei Specitieations u a e ea ein 15 Declaration of ConlormiiYaniann ana E E E Ea 15 LD UNS NS ONS eres e eier 15 AR 1 614 gi le7s l 2 C ener Neen eee ne nee es Renner ee reenter free eee ee eee eee ee erry eee 16 9 DISPOSal cszeseses centres cwecereccrmcceceteec cared a a 18 PLOQUCE ae es ee ee ee 18 07 2013 OPERTIS 3 GB eLOCK Wall scanner controls ES641x ES642x ES641x ES742x Operating instructions 1 Introduction About these instructions These instructions contain important notes and information on operation of the wall scanner controls ES641x ES642x ES641x and ES742x O Read through the instructions carefully and attentively O Keep the instructions in a safe place and pass them on to each subsequent user of the wall scanner controls Explanation of the Symbols and Signal Words Used WARNING Indicates risks which could result in fatal or severe er personal injuries CAUTION Indicates risks which could result in fatal or severe personal injuries Indicates risks which could result in damage to CAUTION property Note Denotes information notes and tips on optimum use of the instructions and the product Target group These instructions are directed at competent personnel entrusted with the servicing maintenance and dispos
13. nting rail version Control of max two external ES0531T relays each with one electromechanical changeover contact Switching capacity Relay make contact NO max 60 V AC DC 2 0 A Connection diagram A Wall scanner CY antenna X External relay for i f Wall scanner mounting rail HO i t antenna 1 installation Jo Wall nner gt scanner 77 control _ gt External relay for WW installation in flush a mounted boxes SPS Basic module SPS Expansion module OPERTIS 17 GB eLOCK Wall scanner controls ES641x ES642x ES641x ES742x Operating instructions Specific data Operating temperature 20 C to 55 C Storage temperature 40 C to 85 C Air humidity for operation and max 95 non condensing storage Degree of protection IP21 according to EN 60529 Memory capacity in standard ES for wall scanner control eLOCK AddDelete Identifiers 100 Protection zones membership of a group of fittings Events authorisation attempts Memory capacity in multi relay ES6 for ES7 for ES7 for wall scanner control ES5000 eLOCK eLOCK plus AddDelete Identifiers 4 350 4 350 Protection zones membership 296 30 of a group of fittings Events authorisation attempts 512 628 9 Disposal Product X Disposal in accordance with WEEE Directive 2012 19 EU O Do not dispose of product by throwing it in the local household waste O Return product to OPERTIS o
14. r dispose of at a municipal collection point for hazardous electrical wastes 18 OPERTIS 07 2013 eLOCK GB Operating instructions Wall scanner controls ES641x ES642x ES641x ES742x 07 2013 OPERTIS 19 OPERTIS Ce OPERTIS GmbH Prof Bier Stra e 1 5 D 34454 Bad Arolsen Telefon 49 5691 87741 0 Telefax 49 5691 87741 310 info opertis de www opertis de M7000 45GBB V004 07 2013
15. sure power supply defective or is not connected Connect the correct power supply Operating voltage not within the allowable range Wall scanner control is Replace wall scanner defective control Fitting is not Program fitting see programmed eLOCK system construction site documentation mode software 07 2013 eLOCK GB Operating instructions Wall scanner controls ES641x ES642x ES641x ES742x 8 Product Specifications Declaration of conformity OPERTIS GmbH herewith declares that the Wall Scanner Controls fulfil the basic standards and other relevant specifications of the 1999 5 EG and 2011 65 EU directives and that they are CE compliant A copy of the statement of conformity can be ordered from the OPERTIS Support Dimensions All dimensions are given in mm Wall scanner controls concealed flush mounted installation 07 2013 OPERTIS 15 GB eLOCK Wall scanner controls ES641x ES642x ES641x ES742x Operating instructions Technical data Installation environment for concealed flush mounted installation Mounting depth 244mm Installation diameter gt 53 mm or standard concealed flush type boxes with 60 mm fixing centres Mounting distance between wall At least 150 mm in 3D space scanner antennas Installation environment for mounting rail installation Housing see Dimensions section 35mm Mounting rail Mounting distance between wall At least 150 mm in 3D space scanner