Home
Operating Instructions Type 0311/0312
Contents
1. Fluid Tempera Buna N o Ethylene PTFE Neoprene tures F Propylene Ethylene Propyl Air Fluid T 14 to 194 40 to 266 14 to 266 14 to 266 14 to 266 Ambient 14 to 130 14 to 130 14 to 130 14 to 130 14 to 130 Water Fluid T 32 to 194 32 to 212 32 to 212 32 to 212 32 to 212 Ambient 32 to 130 32 to 130 32 to 130 32 to 130 32 to 130 Neutral Gas Fluid T 14 to 194 40 to 266 14 to 266 14 to 266 14 to 266 Ambient 14 to 130 14 to 130 14 to 130 14 to 130 14 to 130 Light oil Fluid T 14 to 194 14 to 266 14 to 266 Ambient 14 to 130 14 to 130 14 to 130 LP gas Fluid T 14 to 140 14 to 140 14 to 140 Ambient 14 to 130 14 to 130 14 to 130 Refrigerants Fluid T 14 to 194 Ambient 14 to 130 MAN 1000010133 EN Version J Status RL released freigegeben printed 20 01 2015 burkert Operating Instructions Wiring Diagram Electrical Connection Type 2509 Power Ground green dot Power Orientation is not important Electrical Connection Ensure supply voltage frequency corresponds with that on label Voltage tolerance is 10 Available Electrical Connections see Marking Wiring diagram see above For this product to be considered UL listed and CSA approved for General Purpose and FM approved for Hazardous Locations Division 2 it must be in conjunction with the type 2509 cable plug connector Electrically Operated Valves Par
2. MAN 1000010133 EN Version J Status RL released freigegeben printed 20 01 2015 EU EN_00893135 Operating Instructions 0605 08 burkert Operating Instructions Type 0311 0312 Design 2 way solenoid valve direct acting normally closed Circuit function C normally open Circuit function D or mixer function Circuit function E Seal Materials and Fluids handled See Table Fluid and Ambient Temperature For Hazardous Locations Div 1 T4 rated Max Ambient Temperature 104 F 40 Max Fluid Temperature 194 F 90 For Hazardous Locations Div 1 T6 rated Max Ambient Temperature 104 F 40 Max Fluid Temperature 140 F 60 For Hazardous Locations Div 2 and Ordinary Locations See Table Pressure Range Maximum inlet pressure see label on valve Installation Before installing valve ensure that piping etc is free of foreign matter metal fillings seal materials welding scale etc Instal lation as required but preferably with coil uppermost Installation in this position tends to prevent foreign matter remaining in core tube increased life Do not put any loads on coil unit Type 0311 PTFE tape is recommended for sealing ports Mounting is accomplished by means of four M4 x 8 mm tapped holes located on the valve underside Type 0312 Ports A B are coded on side of body For common pressure align A B marking on valve and manifold Valve operation C and D valves cannot be man
3. ifolded together To remove valve from manifold loosen only the two unsealed screws Manifolds can be connected togehter with nipples Approvals The valve is either approved as General Purpose valve for Hazardous Locations Class Division 1 Group A B C D Class II Division 1 Group E F G Class Ill Division 1 and 2 Operating Temperature T 4 or General Purpose valve for Hazardous Locations Class Division 1 Group A B C D Class II Division 1 Group E F G Class Ill Division 1 and 2 Operating Temperature T 6 or FM approved as Nonincendive for Hazardous Locations Class Division 2 Group A B C D Class II Division 2 Group F G Class Ill Division 1 and 2 Operating Temperature T 4 UL listed for Ordinary locations CSA approved for Ordinary locations See label on the valve Marking example m Circuit function 0311 C 5 64 FKM BR NPT1 4 PMAX 140PSI 8W 24V 60Hz 450000Y IN W GERMANY burkert IRVINE CALIFORNIA U S A MADE W14UN C Normally Closed D Normally Open E Mixer Function Seal Material EPDM EPDM NBR NBR FKM FKM EA PTFE seat and EPDM O ring EF PTFE seat and FKM O ring NN Neoprene RF E Ruby seat and FKM O ring Body Material BR Brass SS Stainless Steel NI Nickel Plated Brass PL Polyamide Plastic Maximum Pressure Voltage Frequency Power Consumption Recorder No Seal Materials Seat O ring
4. subject to change without notice Any questions Please call Biirkert Contromatic Technical Service at 949 223 31 00 burkert Germany Contact address Birkert Fluid Control Systems Sales Center Chr Burkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 1091 111 Fax 49 0 7940 1091 448 E mail info de buerkert com International Contact addresses can be found on the Internet at www burkert com gt Burkert gt Company Locations
5. ts YSYI2 The connector and gasket must be assembled to the valve with the screw provided after the connection of the wire leads This valve and connector assembly is delivered together and is to be used as one unit For valves to be used in Intrinsically Safe Applications the positive pole is identified by a on the pin or wire No 1 has to be con nected to the See Control Drawing for the Rules of Interconnection Warning All valves to be used in Intrinsically Safe Applications must be clearly marked as Intrinsically Safe Apparatus Trouble Shooting Check port connections minimum operating pressure differential if required and supply voltage Ensure pilot hole in piston is clear and pilot bore in the valve outlet is not abstracted If core does not pull in check for short circuit coil burn out or foreign matter im peding core movement A jammed or missing core causes the coil to overheat in the case of AC supply Warning These products are designed to operate in a wide variety of ap plications it is the user s responsibility to select a model that is appropriate for the application This product is designed to be installed only by suitably qualified and trained personnel Specifications should not be exceeded under any circumstances The torque for the terminal screw on type 2509 is 0 5 Nm 4 4 Ibf in Changes made to this product will render any applicable warranty null and avoid Specifications
Download Pdf Manuals
Related Search
Related Contents
Epson 1810p User Replaceable Parts List Caratteristiche tecniche tagliando C0549 rev00. Carta uso E6000 Series - Bike M-IP813 / M-IP814 / M GEMINI Multi-Rotor Autopilot 6000 Series . . . WARNING IMPORTANT FOR YOUR SAFETY 取扱説明 書「 M形埋込み形照明器具 』保管用一 HP 10000 G2 Series Rack Options Installation Guide Copyright © All rights reserved.