1. M LLER ELEKTRONIK 4 2 System description The SPRAYDOS can be installed on the field sprayer as a fully automatic control instrument The device carries out an area related control of the spray rate regardless of the current speed the working width and the pre set rate The calculation of the current spray rate speed working area total area quantity spray as well as the total quantity and the working time is carried out continuously The device consists of the computer 1 and the console 2 5 A wheel cardan speed sensor 9 can be connected directly to SPRAYDOS in order to determine the speed The SPRAYDOS can be connected directly to the signal socket 10 on the tractor using a connecting cable By means of a switch integrated in the connecting cable it is possible to switch between wheel cardan and a radar device lf the SPRAYDOS is being used on a trailed field sprayer no speed sensor is to be connected to the SPRAYDOS In this case the speed is measured at the wheel of the field sprayer The field sprayer is connected by means of the machine plug circulation hydraulic on the SPRAYDOS During transport the SPRAYDOS must be switched off If available the drawbar or axle steering must be setto centre position during transport Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 1l Wa M LLER ELEKTRONIK 5 Installation instructions 5 1 Console and
2. ELEKTRONIK 9 List of diagrams Blagram 4 1 SPRAYDOSSDVEN EN nee 9 Diagram 5 bSensor Xatthe cardan Shall nee 14 Diagraimo 2 Sensor Arte factors WICC Laer OEE Re 14 Diagram a ijo Dr E 16 Page 26 Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015
3. side of the monitor 2 Pressure sensor is connected on the left hand side of the monitor the current spraying pressure in bar is displayed The current spray rate in l ha is displayed on the right hand side If the spray rate exceeds 1000 I ha the rate is displayed with four digits and the pressure with just two digits With both display alternatives an arrow on the left shows that the sprayer is switched on Below this a circle flashes when impulses are being measured by the speed sensor The operating mode is interrupted for 10 seconds when a key is pressed to display another value For each further key pressed the time counter is extended again for 10 seconds Keyboard The keyboard is divided into different areas Operating data This block of keys is used to recall required data By pressing the simultaneously the order is started All counters except ha and l are set to 0 Machine data This block of keys is used to communicate the machine data to the computer Using the keys It Is possible to vary the spray rate in degrees of 10 in relation to the set rate Input keys to enter and alter machine data the keys et and are used Description of the input of machine data Before the device can put into operation the machine specific data must be entered Working width key This key is used to enter the working width Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions S
4. sleeve for strands for the line brown should be fitted using suitable pliers The end sleeve for strands for the line are in the connection clamp of the fuse holder brown 12 volts blue ground The negative pole on the battery must be connected to the tractor s chassis Copyright Muller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 13 i13 M LLER ELEKTRONIK 5 3 Sensor X calculation of the distance Mounting on four wheel drive tractors Mount the hose clamp with a magnet to the cardan shaft The sensor must point in the direction of the magnets at a distance between 5 10 mm It is to be mounted vibration free Diagram 5 1 Sensor X atthe cardan Mounting on tractors without without four wheel drive shaft Install the magnets in the wheel shell using V4A screws eis 1 provided distributing them evenly over the circumference 0 mm The number of magnets depends on the size of the wheel The distance travelled from impulse to impulse must not exceed 60 cm Calculation mie I Wheel circumference 60 cm number of magnets e g 256 cm 60 cm 4 27 2 min 5 magnets Mount the sensor to the steering knuckle using the bracket provided so that the end of the sensors Is pointing towards the magnets The distance should be 5 10mm Mounting on the wheel of the trailed sprayer Magnet rote Seite Mount the sensor on the w
5. If the computer is switched off the input of time data is stopped It restarts once the device has been switched on again The clock can also be stopped I Pn After the key has been pressed it can be pressed once again to h stop the clock To restart it press yet again Spraying fluid l min key Displays the flow meter litres per minute An arrow appears above aaa j Spraying fluid and I key This key has a dual function When the key is pressed for the first time the quantity spray since activating the start function 6 3 1 is displayed for 10 seconds In addition an arrow appears atthe bottom of the display m If within Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 21 M LLER ELEKTRONIK 6 3 6 6 3 7 6 4 6 4 1 6 4 2 6 4 3 Page 22 10 seconds the key is pressed a second time the total number of litres is displayed This value is not deleted by the start I function This enables e g monitoring the tank content After filling the counter is set to 0 by pressing the keys and C simultaneously The quantity of spraying fluid sprayed can be read during operation Speed key When the sprayer is switched off the current speed being travelled is displayed by pressing and also an arrow appears above When a Sprayer with an installed pressure sensor is switched on the speed is displayed on the left hand side of the monitor by pr
6. LK CONIENE KV Mert EIE 22 6 4 Spraying TUMGUON SWIC H nn ncn dre none CD EAERULCOO EE ERE DEDERE FORE DER E 22 6 4 1 Boom section main switch o 22 u J 6 4 2 Manualautomane SWEN ASS m E 22 o 6 4 3 Spraying pressure gt KEY M 22 6 4 4 Boom section switch EEEEEEER nennen 23 6 5 Hydraulic Tunc Dons SWIEE N ai comdxocd v HO EXER AE AMUSO 23 6 5 1 Sner SPRATDOS VSISIOR SEN een 23 6 5 2 Long SPRALDO NE Deere een en 23 6 6 Operating DIOCCAU TE sen a DRE eor onc rb eoo 23 7 MAINTENANCE anna 24 7 1 COMPUTE ania cire bia n n nr e o nra e Fr cr HD P NNN 24 7 2 FIOW Alm 24 8 a m 25 8 1 Technical da nenn 25 8 1 1 BONO SP RALDO VER ON een 25 8 1 2 Short SPRAYDOS version 25 9 LIST OF DIAGRAMS nr anna nen 26 Page 4 Copyright M ller E lektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 M LLER ELEKTRONIK 1 Introduction The SPRAYDOS board computer is a new development on the basis of the well tried and tested SPRAY Control board computer The SPRAYDOS has up to 9 boom section switches with a main switch the manual or automatic regulation of the spray rate and up to 4 hydraulic functions the long version allows a further 10 hydraulic functions as soon as foam marker and corner nozzles The current speed and the current spray rate are displaye
7. M LLER ELEKTRONIK Installation and operating instructions SPRAYDOS Version V1 20150309 30221020 02 EN Read and follow these operating instructions Keep these operating instructions in a safe place for later reference Company details Document Installation and operating instructions Product SPRAYDOS Document number 30221020 02 EN Original language German M ller Elektronik GmbH amp Co KG Franz Kleine Stra e 18 33154 Salzkotten Germany Phone 49 0 5258 9834 0 Fax 49 0 5258 9834 90 Email info mueller elektronik de Homepage http www mueller elektronik de M LLER ELEKTRONIK Table of contents 1 INTRODUCTION suicida nodo d o rV E EHE FR CERE 5 2 SAFETY INSTRUCTION Sarnen 6 2 1 Intended USC asinine RENTER 6 2 2 Basic safety INSTUCHONS osasinadacenid on ean da CU v EE d RUE EE c ER 6 2 3 Layout and meaning of warnings rrr nennen n 6 24 Safety notice for the subsequent installation of electrical and electronic devices and or components 7 3 EC DECLARATION OF CONFORMITY iiic Diva C P E ci rc c 8 4 OVERVIEW AND SYSTEM DESCRIPTION rrr nre nre neret 9 4 1 OVGIVIOW X H 9 4 2 System GESCH NUON seen 11 5 INSTALLATION INSTRUCTIONS nassen 12 5 1 Console and COMPUTED nennen 12 5 2 Battery connechng CabDIe Blasien Oti RO Rn D Co ren andis 12 5 3 Sensor X calculation of the distance een 14 5 4 Adap
8. M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 M LLER ELEKTRONIK Danger of injury from explosion of the vehicle battery If the battery terminals are loose fitting starting the vehicle can cause the vehicle battery to overheat The vehicle battery may then explode o Always tighten the battery terminals firmly after assembly Damage to the vehicle s electrical system Switching the polarity of the cables can cause damage to the vehicle s electrical system o Pay attention to the polarity of the cable cores and the terminals gt Ensure that the vehicle is switched off gt Insert the blue cable core 4 into the OV ring tongue 5 gt nsertthe brown cable core into the free end of the butt connector 2 gt Pinch with a crimping tool Shrink both of the butt connectors with a heat source e g hot air gun until the adhesive emerges gt Connect the ring tongues to the battery terminals of the vehicle battery Pay attention to the polarity beginning with the positive terminal gt Fasten the battery cable with cable ties Ensure that there is sufficient distance from moving parts and parts generating large amounts of heat Operating voltage is 12 V and must be taken directly from the battery or from the 12 volt starter Care should be taken when laying the cable 6 and it should be shortened if necessary The crimpon ring terminal for the ground line blue and the end
9. PRAYDOS 03 2015 M LLER ELEKTRONIK gt Press the working width key ih gt Enterthe value using the keys 8 and gt gt Press m to transfer the new value Imp 62 2 Impulses 100m key With this key the number of impulses which the speed sensor records to the computer is entered There are two possibilities to enter the data The impulses 100m value is known gt Press gt Enter the value using the keys 8 and gt Press am to transfer the new value 2 The impulses 100m value is not known gt Measure out and mark a distance of 100m on the field gt Bring the vehicle to the start position Press M and C simultaneously Travel a distance of 100m and stop The computer counts the impulses during the journey gt Press to transfer the new value V V 6 2 3 Number of boom sections key This key is used to enter the number of boom sections max 9 and the number of nozzles for each boom section The boom sections are numbered from left to right as seen from the direction of driving During input the boom sections are displayed on the left hand side and the number of nozzles on the left hand side Procedure gt Press EZ on the lefta 1 boom section 1 is displayed and on the right the number of nozzles gt To alter the number of nozzles enter the new value using the keys Jand gt Press the value is now stored in the memory On the left hand side of the display a 2 boom section 2 a
10. computer The basic console 5 must be mounted vibration free and electroconductive to the cabin on the driver s right hand side and within his visual range and reach The distance to the radio or to the radio antenna should be at least 1 m Attach the bracket 4 to the tube of the basic console Mount the cap profile rail 2 on to the bracket Push the SPRAYDOS computer 1 from above on to the profile and secure using the wing nuts 3 The console can be swivelled to allow the display to be adjusted to the optimal angle of vision which lies between 45 and 90 from below Please ensure that the computer casing 1 has a lead connection to the tractor s chassis above the console 2 5 When mounting remove the paint from the mounting points 5 2 Battery connecting cable 6 DG T Free end of the butt connector Loose ring tongue ground OV 3 Ring tongue 12V Risk of injury caused by short circuit Connecting the positive terminal and the vehicle mass when working on the battery terminals can cause a Short circuit This can cause burn injuries to persons o When working on the battery terminals ensure that no connection is created between the vehicle battery and the vehicle mass Remove metallice items such as watches and rings before starting work When disconnecting the terminals always begin with the negative terminal Always begin reconnecting the terminals with the positive terminal Page 12 Copyright
11. d pressure manifold without reflux measurement The manifold is equipped with electrovalves and separate balanced pressure valves e g Tecnoma Elektra The spraying fluid which flows back to the tank via the balanced pressure valves when the boom section is switched off is not recorded by the flow meter Manifold without balanced pressure function The manifold is equipped with motor or electromagnetic valves Only the quantity sprayed via the spray bar is measured by the flow meter even when the boom section is switched off If at the end of the field with the sprayer switched off one or more boom sections are switched off the computer takes a pre setting via the control valve Fine tuning then takes place once the field sprayer has been switched on Balanced pressure manifold with reflux measurement The manifold can be equipped with either motor or electromagnetic valves When boom sections are switched off the flow meter also measures the amount which flows back to the tank The computer takes this into account when calculating the quantity sprayed depending on the number of nozzles per boom section Example Field sprayer with 5 boom sections One boom section is switched off only 4 5 of the total quantity is recorded 1 5 flows back into the tank The valves on the balanced pressure manifold must be set accurately Spraying devices without balanced pressure function This setting takes into account the specific features of spra
12. d simultaneously If an automatic pressure sensor is installed the pressure is displayed instead of the speed The speed appears on the display when the km h key is pressed for about 5 seconds Specific applications can be carried out by pressing the 10 key The pre set rate resets by means of the I ha key The spray rate is adhered to accurately even when the speed varies Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 5 M LLER ELEKTRONIK 2 Safety instructions 2 1 Intended use e he SPRAYDOS is specified exclusively for agricultural use and in wine fruit and hop growing The manufacturer takes no responsibility for any installation or application outwith this area e The manufacturer does not accept liability for damage to persons or property resulting from unspecified use In Such cases all risks are the responsibility of the user e Specified implementation also includes adhering to the operation and maintenance requirements stipulated by the manufacturer e Relevant accident prevention regulations as well as other generally recognised safety industrial health and road traffic rules are to be adhered to In addition the manufacturer accepts no liability in cases where arbitrary modifications have been made to the device 2 2 Basic safety instructions Observe the following recommended precautions and safety instructions e Donotremove any safety devices or labe
13. e The various possibilities are described in the chapters 6 2 5 1 6 2 5 3 Impulses per litre input If the number of flow meter impulses per litre is known the value can be entered directly 1 The value impulses litre is known mo gt Press gt Enter the value using the keys and gt Press af to transfer the new value Tank method With the tank method calibration is carried out by weighing the entire field sprayer before and after spraying The procedure Is as follows gt Fill the tank with water and determine the quantity weigh Imp l gt Press Co and e simultaneously gt While stationary switch on the field sprayer using 9 and spray a few hundred litres The computer now counts the flow meter impulses gt Switch off the sprayer using gt Determine the amount sprayed reweigh gt Setthe value using the keys and gt Press to transfer the new value gt The computer calculates the impulses litres The flow meter impulse number should be checked several times a year especially before each season Nozzle method With the nozzle method the quantity sprayed is measured at a nozzle and projected to the total number of nozzles The procedure is as follows gt Fill the tank with water gt Secure a measuring jug below a nozzle Copyright Muller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 M LLER ELEKTRONIK Imp il gt Pr
14. ess ime and e simultaneously gt While stationary switch on the field sprayer using 9 until the measuring jug has been filled with e g 2 litres the computer counts the flow meter impulses gt Switch off the sprayer using gt Determine the amount sprayed read the quantity in the measuring jug and multiply by the number of nozzles gt Setthe value calculated using the keys and gt Press E to transfer the new value gt The computer has now calculated the impulses litres 6 2 6 Type key This key is used to enter 2 functions The number before the comma determines the manifold type The 2 positions after the comma determine the control constant Typ gt Press gt Setthe value using the keys 5 and gt Press xi to transfer the new value 6 2 6 1 Manifold type The manifold type is communicated to the computer via the number before the comma The following manifold types are taken into account in the example a control constant of 15 is assumed Parameter Manifold type 0 15 Balanced pressure manifold without reflux measurement 1 15 Manifold without balanced pressure function 2 15 Balanced pressure manifold with reflux measurement e S praying devices without balanced pressure function Manifold type number before the comma Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 19 M LLER ELEKTRONIK 6 2 6 2 Page 20 Balance
15. essing this key for 5 seconds In addition an arrow appears above LAA This key has no function when there is no pressure sensor as in this case the speed is displayed permanently in the job display Tank content key Ifa Tank Control is connected the tank content can be called up by yes E The value is displayed for 10 seconds Spraying function switch Boom section main switch 9 The boom section main switch switches the sprayer s main valve When switched on spraying begins with all switched on boom sections D Manual automatic switch This switch can be used to switch between automatic and manual operation In Auto position the computer controls the spray rate automatically If the switch is set at Manual the correct spraying pressure must be set manually by means of T the key Spraying pressure key This key is for manual adjustment of the spraying pressure in manual operation mode Manual operation is selected by E means ofthe switch Copyright Muller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 6 4 4 6 5 6 5 1 6 5 2 6 6 MULLER ELEKTRONIK WEHR ae ee The function of the boom section switch is to switch the individual boom sections If a switch is off then the corresponding boom section is also switched off and cannot be switched on by means of the boom section main switch Hydraulic functions switch Short SPRAYDOS ver
16. heel of the field sprayer in the same way as on the wheel of the tractor see diagram 5 2 In this case the electrical connection is in the machine distributor manifold Diagram 5 2 Sensor X on the tractor s wheel If an X sensor is connected in the machine distributor no sensor is to be connected to the SPRAYDOS 5 4 Adapter cable for tractors with signal socket In this case it is not necessary to install the X sensor The SPRAYDOS is connected to the tractor s signal socket using the adapter cable 10 Page 14 Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 M LLER ELEKTRONIK 5 5 Connection on the field sprayer The attached or trailed field sprayer is connected via a 39 channel machine plug manifold With the SPRAYDOS long version the machine plug hydraulic must be connected in addition Copyright Muller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 15 M LLER ELEKTRONIK 6 6 1 6 2 6 2 1 Page 16 Operating instructions Function description Display km h ha I min h Sha Sl Diagram 6 1 Display During normal operation the operating mode is always displayed on the monitor There are two alternatives l Pressure sensor is not connected on the left hand side of the monitor the speed is displayed and an arrow appears above The current spray rate is shown on the right hand
17. ls e Before using the SPRAYDOS read and understand this guide It is of equal importance that others operating this device also read und understand the manual e During maintenance or when using a battery charger switch off the power supply e Never service or repair the device while the job computer is switched on e Before welding on the tractor or on an attached machine interrupt the power supply to the SPRAYDOS e Only use a soft damp cloth with clear water or a little glass cleaning agent to clean the SPRAYDOS e Operate the keys with your finger tips but avoid using fingernails e Should any part of this guide remain incomprehensible after reading contact the dealer or Mueller Elektronik Service for further clarification before using the SPRAYDOS e Read carefully all safety instructions in the manual e learn how to operate the SPRAYDOS correctly Nobody is to operate the machine without exact instructions e Keep the SPRAYDOS and the spare parts in good condition Unspecified alterations can impair the function and or safety and affect the life span of the machine 2 3 Layout and meaning of warnings All safety instructions found in these Operating Instructions are composed in accordance with the following pattern This signal word identifies medium risk hazards which could potentially cause death or serious physical injury if not avoided This signal word identifies low risk hazards which could potentially cause minor or mode
18. lug ug Mo hydraulic u m X 9 ria a Bracket N Basic console n Continuos current socket s DIN 9680 brown blue A L Tractor Implement PS ro ie Al V Machine signal e E distributor for sprayer Sensor X Wheel m M m Bg Diagram 4 1 SPRAYDOS overview Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 9 M LLER ELEKTRONIK bersicht Page 10 1 2 3 4 5 6 7 8 9 10 11 SPRAYDOS computer Cap profile rail for mounting the SPRAYDOS Wing screw to secure the computer Bracket S for mounting the cap profile rail Basic console to be mounted on the tractor cabin For fitting the bracket with cap profile rail and battery connection Battery connecting cable for the SPRAYDOS voltage supply connection to a 12 volt battery Machine signal distributor Combines the sensor and actuator connections on the machine Sensor X wheel records distance impulses on the trailed field sprayer Sensor X cardan shaft wheel records speed impulses on the cardan shaft or front tractor wheel Plug for tractor signal socket records the signals from the installed sensors on the tractor Hydraulic signal distributor Combines the hydraulic connections on the machine for SPRAYDOS long version Copyright Muller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015
19. ppears If the value number of nozzles on the right hand side of the display is correct press to transfer the value and select boom section 3 This process can be carried on until the 9 boom section is reached Subsequently the total number of boom sections and nozzles will be displayed gt Ife g the field sprayer has 5 boom sections enter a 0 when the 6th boom section is displayed The computer then sets the boom sections 7 9 automatically to 0 In this case the computer operates on the basis of 5 boom sections and displays the number of boom sections and the total number of nozzles as 5 30 6 2 4 Pre set rate I ha key The required spray rate is communicated to the computer using this key If the switch is in automatic position the electronics control the pressure and subsequently the spray rate automatically Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 17 mE M LLER ELEKTRONIK 6 2 5 6 2 5 1 6 2 5 2 6 2 5 3 Page 18 If due to a fault e g tank empty the pre set rate is not achieved an alarm is set off Ilha Input value liha gt Press gt Enter the value using the keys and gt Press to transfer the new value ihe The value entered is controlled by pressing again Impulses litre key Direct input of impulses per litre or a calibration of the flow meter can be carried out her
20. rading with mobile communication systems e g radio telephone e Only approved devices complying to national regulations e g BZT approval in Germany are to be installed e The device must be securely installed e The use of portable or mobile devices inside the vehicle is permissible only via a connection to a permanently installed outside antenna e The transmitting unit is to be installed in a position away from the vehicle electronics e Anantenna should only be installed professionally ensuring that there is a good earth connection between the antenna and the vehicle chassis Please refer to the manufacturer s installation instructions for cabling and installation as well as the maximum current consumption Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 7 M LLER ELEKTRONIK 3 EC declaration of conformity This product has been manufactured in conformity with the following national and harmonised standards as specified in the current EMV Directive 2004 1008 EG e EN ISO 14982 Page 8 Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 M LLER ELEKTRONIK 4 Overview and system description 4 1 Overview _ Al SDBavhne 5 me a Se DOS ml E 2 E y 000000000 ff 900000000 o To nannannann c Machine plug ok manifold i c M Machine p
21. rate physical injury or damage to property if not avoided Page 6 Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 M LLER ELEKTRONIK This signal word identifies actions which could lead to operational malfunctions if performed incorrectly These actions require that you operate in a precise and cautious manner in order to produce optimum work results 2 4 Safety notice for the subsequent installation of electrical and electronic devices and or components Present day agricultural machines are equipped with electronic components and devices whose function can be affected by electromagnetic emission from other devices These influences can lead to endangerment for individuals when the following safety measures are not adhered to When subsequently installing electrical and electronic devices and or components in a machine with a connection to the electrical system the user must take sole responsibility for testing the installation for interference of the vehicle electronics or other components This applies in particular to the electronic controls of e EHR e Front lifting gear e Power take off shafts e Motor e Gears Above all it must be ensured that all subsequently installed electrical and electronic components comply with the current version of the EMC directive 89 336 EWG and carry the CE symbol In addition the following requirements must be fulfilled when upg
22. sion The short SPRAY DOS version supports a maximum of 4 hydraulic functions For this purpose up to 4 switches can be mounted on the top right hand area of the computer The function of each of these switches is illustrated by the pictograms on the tactile keyboard Long SPRAYDOS version The long SPRAYDOS version has an additional row of switches underneath the section switches Here up to 10 hydraulic functions as well as foam markers and corner nozzles can be accommodated Pictograms illustrate their function Operating procedure Once the machine data have been entered 6 2 1 6 2 6 only the start function 6 3 1 has to be activated before operation can begin During operation all values can be called up The automatic mode guarantees accurate dosage Please ensure that the pressure in connection with the drop formation for the nozzle type in operation is maintained At times when the field sprayer is switched on and off the same speed should be driven if possible to avoid brief under dosage or over dosage after switching on the field sprayer e M If regulation is to be carried out manually setthe switch to manual The quantity is controlled using the key Once the job is completed all values can be called up A new job begins with the start function 6 3 1 Before initial operation fill the sprayer with water without spraying fluid Start the field sprayer Subsequently check the values measured and di
23. splayed Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 23 M LLER ELEKTRONIK 7 Maintenance 7 1 Computer The computer is maintenance free It has an internal safety fuse During the winter it should be stored at room temperature and protected from dampness 7 2 Flow meter Rinse the flow meter with water each time after use At the end of the season check the run of the impeller wheel and replace if necessary At the beginning of each season carry out a calibration process see 6 2 5 Page 24 Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 M LLER ELEKTRONIK 8 Appendix 8 1 Technical data 8 1 1 Long SPRAYDOS version Tightness IP 54 Typ curenti 23 C 470 C ERSTER o Individual sections 1 85A 1 13A Bypass 2 50A 1 53A Hydraulic cpl opt 6 00A 3 66A Slope opt 6 00A 3 66A Boom potentiometer 10A electrical cutoff Regulation duration 3 00A Peak 6 00A 8 1 2 Short SPRAYDOS version Tightness IP 54 Typ curentrating ses Individual sections 2 50A 1 93A Bypass 2 50A 1 93A Hydraulic cpl opt 4 00A 3 08A Slope opt 6 00A 4 62A Boom potentiometer 10A electrical cutoff Regulation duration 3 00A Peak 6 00A Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 25 M LLER
24. ter cable for tractors with signal socket nemen 14 5 5 Connection on the field SDIalelusoansannd ea 15 6 OPERATING INSTRUCTIONS nam ann 16 6 1 Function descrpDonauminriniirrniinnninidie nor procol Fn nc 16 6 2 Description of the input of machine data nnns 16 6 2 1 BURNS 16 Imp 6 2 2 uuuuuuudEcG OO 17 rem 6 2 3 Number of boom sections key BEBE 17 Wh 6 2 4 MP Rao EN CY ERES 17 Imp l 6 2 5 Impulses litre key Co A M 18 5251 FDU SST SUE saco compdtotouttm hte a du br Qd eb M Mb DIIS ID UM Mtn 18 ESTEE udi cu RR 18 DAC NOZZE MOT eO 18 6 2 6 Wi Mp ee ee nen ee ee 19 0 201 MONIO ED ee RETTET 19 07 02 Control ConstaMS om 20 6 2 7 t 10 90 10 100 C m 21 Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 Page 3 M LLER ELEKTRONIK 6 3 Description of the operating data keys nennen nennen nnns 21 6 3 1 OEL TUNIC HON eee c H 21 6 3 2 Area total area 5 ER 21 6 3 3 Ee cA m V 21 6 3 4 pee aae TTMT HU 21 6 3 5 E reEEknP3ET I Meu 21 6 3 6 Speed eL REINER 22 6 3 7 PU
25. ual adjustment of the spray rate has been carried out 100 10 1 10 By pressing the key a manual adjustment of the spray rate by means of the keys is cancelled out again The value entered with the key is once again set as the pre set value The file above disappears again Description of the operating data keys Start function The start function is activated by pressing the eyo A i e the memory for the area spraying fluid and time is setto 0 Time starts automatically when this key is pressed This function is to be carried out before each job ha Area total area This key has a dual function When the key is pressed for the first time the area covered since activating the start function Is displayed for 10 seconds In addition an arrow appears atthe bottom of the display above A If within 10 seconds the key is pressed a second time the total area is displayed This value is not deleted by the start function This enables the total area for a season to be determined At the beginning of the season the counter is set to 0 by pressing the keys ha and C simultaneously The area calculation adapts to current conditions S witched off boom sections are automatically taken into account Measurement is interrupted as soon as the field sprayer is switched off at the main switch Time key Ml time since activating the start function 6 3 1 is displayed when this key is pressed An arrow appears abovelid
26. ying devices for use in fruit wine and hops production In this case the quantity and not the working width is altered when the upper nozzle segments are switched off If one side of the device is completely switched off the working width is halved Control constants Depending on the fabrication and the size of the sprayer different control times are required when there is a certain deviation from the pre set value The computer calculates the control time with which the control valve is driven The control time is determined by the control constant gt Regulation too sluggish gt enter a highter value gt Regulation overdrive gt enter a lower value The control constant is optimally selected when in the case of a deviation from the pre set value one control process is sufficient for the computer to get to the proximity of the pre set value and then fine tune by means of a few small processes Regulation can be seen in the display l ha Control constants can be within the range of 1 to 99 See also 6 2 6 1 Manifold types Copyright M ller Elektronik GmbH amp Co KG Installation and operating instructions SPRAYDOS 03 2015 6 2 7 6 3 6 3 1 6 3 2 6 3 3 6 3 4 6 3 5 M LLER ELEKTRONIK 410 77 10 L7 100 96 C keys During operation the sprayed rate can be adjusted in degrees of 10 in relation to the pre set rate by using the keys andk 4 An arrow in the display above Shows that a man