Home

Operating Instructions Busch

image

Contents

1. The glass break sensor is an optional sensor which can detect a broken window pane When a window pane cracks ultrasonic signals are created which are evaluated by the sensor evaluates The sensor triggers a DOWN command During or after triggering of the switch command the blind cannot be moved up neither via the brightness sensor nor via a timer signal nor via an extension unit The lowered blind can only be raised again via the control element of the affected flush mounted insert When using a timer control element a separate signal is sent to the control element see the relevant operating manual The flush mounted insert automatically detects a connected glass break sensor For larger glass areas up to four glass break sensors can be combined on a single pane and connected to a flush mounted insert O 3 O e 016 o Y 35 E Fig 5 Connected glass break sensor Operating Instructions 1473 1 8162 Operating Instructions Busch Jalousiecontro 5 Technical data O d Technical data Designation Value Nominal voltage 230 V AC 10 50 Hz Maximum switching current 3 A cos q 0 5 Power consumption lt 1W Relay ON period Approx 3 minutes Relay switchover pause gt 500 ms Maximum power consumption per extension unit input lt 3 mA Sensor connection Ambient temperature SELV potential Protective
2. 1 controls the entire group of blind motors All other blind control devices can be used to also move the blinds individually O Note A combination of flush mounted inserts 6411U 101 6411 U and 6410U 102 is possible Operating Instructions 1473 1 8162 12 Operating Instructions Busch Jalousiecontrol II Installation and electrical connection Extension unit 6411 U 101 Fig 8 Polyphase operation Warning Electric voltage Risk of death due to electrical voltage Polyphase operation is permitted only in Germany Switch off all phases of the device during a fault or when working on the system f you wish to connect several motors in parallel observe the instructions of the respective manufacturers of the blind motors Neither persons nor objects are permitted in the vicinity of the operating radius of the blind If polyphase operation two phases is desired for the control and function of flush mounted insert 6411U 101 the following conditions must be fulfilled according to DIN VDE 0100 e Connection according to the circuit diagram in the Busch Blind Control II user manual When using in different Fl circuits When using via 3 phases The phase for the extension unit inputs terminal 1 and 2 must be equal and in the same electric circuit Operating Instructions 1473 1 8162 13 Operating Instructions Busch Jalousiecontrol Installation and electrical conn
3. A long actuation of the operating surface causes the blind to travel UP DOWN for the duration of the actuation If the actuation is longer than three minutes the flush mounted insert will switch itself off Slat operation L The brief actuation of the operating surface is identical to standard operation A long actuation of the operating surface causes the blind to travel Up Down clocked for the duration of the actuation If the actuation is longer than 3 minutes the flush mounted insert will switch itself off Central unit Z In this operating mode a flush mounted blind control insert is used as central unit for additional blinds At each actuation brief or long of the central unit the blinds move to their end position Programmed down times of the extension units are executed Programming P Individual travel times of the blind can be programmed E g if the blind is to travel automatically down to a certain position and adjust the slats The programmed travel time will become active after a switchover into a different operating mode only if previously the blind travelled up as a result of a travel command 3 minutes Only this will ensure that the blind will travel to the desired position Awning function M only for 6411 U S 101 This operating mode is effective only in version 6411 U S 101 with a brightness sensor connected Without a brightness sensor this operating mode has no effect and is ide
4. 1473 1 8162 Rev 01 17 12 2012 Operating Instructions Busch Jalousiecontrol II Busch Jalousiecontrol Flush mounted inserts r 6411 U 101 i 6411 U S 101 Busch N na Jalousiecontrol TI 6411 U S 101 230V 50Hz 3A cos p0 5 p xt O BUSCH JAEGER V Operating Busch Jalousiecontro Instructions I 11 1 A M EEE 3 2 Intended se ce t eO eR ERE P e d ttd bib ed ttim ud 3 3 ENVIO Medias dia 3 4 Setup and UNION a e daa 4 4 1 Moa A 4 4 2 Overview OF device Sh iscriere ede Aia 5 4 3 Features of function and equipment ssssssssseeneneeene eene nnnen ene nen nnne enne enne 5 4 4 Extension nit inputs eicere eren R danes 6 4 5 Brightness sensor iii A ete gerente cie rere e te ener aa eue e Pe Pose Eve cons 7 4 6 Class DESK SENSO iii estate ntee netuertarnducndes sdbngeshabhacese saute AEE A AEREE 7 5 Technical data x 2 ds idee etaed 8 6 Installation and electrical connection sssssseseeeneneen nennen enne enne nennen nne 9 6 1 Requirements for the electricidad 9 6 2 Mounting in connection with other devices ooonnoninncccnnnocicinoconnnononnnonanoncnnnnrn cnn ono nn nr nennen nnne enne 10 6 2 1 Mounting with IR control element iriiritia eaa e a nennen nennen 10 6 2 2 Mounting with SOTS OTS a a p a e n ae ra enm ene eren nn nene rr innere nennen e entren nennen nennen 10 6 2 3 Mounting with extension units oooo
5. Safety 1 Safety Warning Electric voltage Risk of death and fire due to electrical voltage of 230 V Work on the 230V supply system may only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly 2 Intended use The device is to be used exclusively with the components that are supplied and licensed as described in chapter Setup and function 3 Environment Consider the protection of the environment Used electric and electronic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot All packaging materials and devices bear the markings and test seals for proper disposal Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies The products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EC WEEE and 2002 95 EC RoHS EU REACH ordinance and law for the implementation of the ordinance EC No 1907 2006 Operating Instructions 1473 1 8162 3 Operating Instructions Busch Jalousiecontrol II Setup and function 4 Setup and function The flush mounted inserts described in this instruction manual are for the control of Blinds sl
6. The blind travels down for 3 minutes Deleting programming 1 Switch into operating Programming P while the control element is pulled off 2 Switch back to the previous operating mode Programming has been deleted Operating Instructions 1473 1 8162 19 Operating Instructions Busch Jalousiecontro 7 2 6 Party function O dl Operation The Party function can be activated only when combining the flush mounted inserts 6411 U 101 and control elements 6430 With this function the flush mounted insert is excluded from a group control This means that signals which arrive via the extension unit inputs and local operation are ignored The function can only be activated when the blind is in the top end position Please observe the relay operating time of 3 minutes Enable e Activate the UP button for 5 seconds As acknowledgement the blind travels down for two seconds and then back up to the top end position Deactivate Actuate the DOWN button for 5 seconds As acknowledgment the blind moves down The deactivation is carried out automatically after approximately 8 hours Activating the party function deactivates the sun protection the twilight and the awning function The Party function cannot be activated in Central unit and Programming operating modes 7 3 Fault rectification Diagnosis Possible cause Fault rectification Blinds move differently with group control Outputs hav
7. ait a few seconds 3 Turn the adjusting wheel 1 to the maximum value left end stop This activates the programming of the brightness value The blind travels if it is not already at the top to the top as a sign of having acknowledged this operating mode 4 Now turn the adjusting wheel 1 slowly to the right in the direction of reducing brightness until the blind travels down This stores the current brightness value The sun protection function is directly active 7 2 4 2 Setting for timer control elements 6455 and 6412 101 The sun protection function and the twilight function can only be set in connection with the timer control elements The setting is made via the timer control element The adjusting wheel of the flush mounted insert then has no function Fore more detail see the relevant operating manual of the timer control element Operating Instructions 1473 1 8162 18 Operating Instructions Busch Jalousiecontrol II Operation 7 2 5 Programming the travel times Individual travel times can be programmed in operating mode Programming P to move the blind to a specific intermediate position Programming procedure 1 Prior to programming move the blind to the top end position 2 Setoperating mode Programming P See chapter Changing the operating mode page 15 3 Move the blind down to the desired position with a long actuation of the operating surface An interim stopping of the blind is possible All DOWN
8. ats Roller shutters Awnings Dome light covers etc The U S version additionally has the option of connecting a brightness sensor and a glass break sensor as well as a adjusting wheel for setting the threshold value of the brightness sensor In the following the term Blind is also used representatively for other applications 4 1 Modules 6411 U S 101 6411 U 101 Y laleusecomrol S Jalousiecontral Il ENT Nott PEL ec 6430 6066 Fig 1 Flush mounted inserts with control elements Three control elements are available for the flush mounted inserts Different functions are available depending on the control element Mechanical control element 6430 Local operation Brief press of the button moving to end position Long press of the button adjusting IR control element 6066 Local operation Like the mechanical control element plus control option via IR remote control Comfort timer control element 6455 Local operation Like the mechanical control element plus moving and positioning of the blind via time and brightness that can be freely adjusted Operating Instructions 1473 1 8162 A Operating Instructions Busch Jalousiecontrol II Setup and function 4 2 Overview of devices Fig 2 Device view Item Designation Flush mounted insert Network e
9. avels up or down as long as the button is pressed When operating mode L is selected Button Function Actuation Result Brief press of the button The blind travels to the top or bottom end position ASN Blind UP y HUN f A renewed brief press of the button stops the blind immediately NY Long button press Blind DOWN f The blind travels up or down clocked as long as the button is pressed This causes the angle of the slats to be changed in stages 7 2 2 Operation via IR control element 6066 Manual local operation as well as remote control via IR remote control 6010 25 takes place analogous to the actuation of control element 6430 On IR control element 6066 the red LED flashes during sending operation 7 2 3 Operation via extension units All types of signal generators that supply a 230 V signal no continuous signal to extension unit inputs 1 and 2 are suitable as extension units The operation depends on the respective scope of functions of the extension unit and the operating mode selected The flush mounted insert interprets the brief voltage pulses as a brief actuation touch and the long voltage pulses as a long actuation Priority of operation The glass break sensor has the highest priority When it is triggered the extension unit inputs are deactivated The blind travels down and can only travel up again with a local operation Extension unit input 2 for UP has the second highest priorit
10. e been switched Switch outputs on 6411 U S 101 Extension units have been switched Switch extension unit inputs on 6411 U S 101 Load and control lines have been installed too close Separate load lines and control lines Adhere to a minimum distance of 5 cm Blind does not move during group control Extension unit input with higher highest priority is active e g wind alarm Blind does not move Thermal protection of motor is active Wait for a short period Slats are not adjustable Incorrect operating mode is set Check operating mode Blind no longer travels via extension unit and local control Party function is active Deactivate party function Operating Instructions 1473 1 8162 Operating Instructions Busch Jalousiecontrol II A member of the ABB Group Busch Jaeger Elektro GmbH PO box 58505 L denscheid Freisenbergstrake 2 58513 L denscheid Germany www BUSCH JAEGER com info bje de abb com Central sales service Phone 49 0 2351 956 1600 Fax 49 0 2351 956 1700 Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained the
11. ection 6 4 1 Brightness sensor and glass break sensor O Note The brightness sensor and the glass break sensor can only be used in connection with flush mounted insert 6411 U S 101 1 If necessary remove the control element from the flush mounted insert 2 Lever off the cover 3 carefully Pull the terminal block 1 out carefully 4 Connect the brightness sensor and or the glass break sensor Ensure that the polarity of the cables is correct on the brightness sensor S Brightness sensor light grey L Earth white G Glass break sensor e 5 Asa strain relief install the sensor cable with a small loop in the loop compartment 2 6 Do not extend the sensor cable otherwise impairment of functions can result Fig 9 Connecting the sensor For additional information on fixing the glass break sensor see the relevant operating manual Operating Instructions 1473 1 8162 14 Operating Instructions Busch Jalousiecontrol II Operation 7 Operation 7 1 Operating modes PXOM P L Z N L Z N 6411 U S 101 6411 U 101 Fig 10 Operating mode selector Operating mode Actuation Function Normal operation N factory setting A brief actuation touch of the operating surface triggers a travel command which causes the blind to travel to its upper or lower end position Another actuation interrupts the upward or downward travel
12. low voltage 0 35 C Operating Instructions 1473 1 8162 Operating Instructions Busch Jalousiecontrol II Installation and electrical connection 6 Installation and electrical connection Warning Electric voltage Risk of death due to electrical voltage of 230 V during short circuit in the low voltage line Low voltage and 230 V lines must not be installed together in a flush mounted socket 6 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect from power 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth and short circuit 5 Cover or barricade adjacent live parts Use suitable personal protective clothing Use only suitable tools and measuring devices Check the supply network type TN system IT system TT system to secure the following power supply conditions classic connection to ground protective earthing necessary additional measures etc Operating Instructions 1473 1 8162 9 Operating Instructions B
13. ng Electric voltage Risk of death and fire due to electrical voltage of 230 V Work on the 230V supply system may only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly The flush mounted insert must only be installed in flush mounted wall boxes according to DIN 49073 1 Part 1 or suitable surface mounted housings Operating Instructions 1473 1 8162 10 Operating Instructions Busch Jalousiecontrol II 1 Connect the cables to the flush mounted insert For the connection assignment see chapter Electrical connection on page 12 2 Mount the flush mounted insert 3 Plug the attachment together with the frame onto the flush mounted insert Ensure that the plug in connection on the rear side does not get jammed If mounting is difficult check whether a burr has formed at the lock in opening of the flush mounted insert and remove it The device is now mounted 4 Actuate the UP and DOWN button while at the same time checking the travel direction of the blind Installation and electrical connection Operating Instructions 1473 1 8162 11 Operating Instructions Busch Jalousiecontrol II Installation and electrical connection 6 4 Electrical connection 16A L1 N 6411 U 101 Fig 6 Individual control Blind control 1 2 3 Fig 7 Group control Blind control
14. nocononcccnnnoccncnonannno nono nonnnoncnn nono emm oeae nennen nenne nennen nennen nennen 10 6 3 eeu o 10 6 4 Electrical connection 11e reete A a 12 6 4 1 Brightness sensor and glass break sensor sssssssseeeeeene conan nn nn nana nn rr nn nn enne nnn 14 7 Gu pa 15 7 1 Operating Modes renien Eno t de tet eee adeno ee dee dte e Ho e Ege re redde dia ees 15 7 1 1 Changing the operating mode eo neceeie iia 15 7 2 Operation in connection with other devices oooononncnnnnoccnononcccnonannnnnono nono non eee eere nnne 16 7 2 1 Operation via control element 6430 sss eene ene neneenennrnnen nnn nennen 16 7 2 2 Operation via IR control element 6066 ssssssssessseeene eee nano nn rn nennen nnne enne 16 7 2 3 Operation via extension units sse nennen ennemi enne enne inneren nenne 16 7 2 4 Brightness Sensor ned omues nane 17 7 2 4 1 Setting for control elements 6430 and 6066 oocoonocccinococcnonoccnonononcnonononcnnnonnncnnnn nennen nennen enne 18 7 2 4 2 Setting for timer control elements 6455 and 6412 101 sss emen 18 7 2 5 Programming the travel tires cerei ada 19 7 2 6 Party TUnCtion E 20 7 3 Fault rectification rsin ae e dae e ee a e et dades 20 Operating Instructions 1473 1 8162 2 Operating Instructions Busch Jalousiecontro
15. ntical with standard operation N Awning function When the set brightness value is exceeded the blind travels down for 3 minutes or for a pre programmed down time The blind automatically travels up when the brightness value becomes too low only when the travel time ensures that the sensor has an unrestricted view of the sun 7 1 1 Changing the operating mode O Note The operating mode can be changed when the electric voltage is connected 1 Pull the control element from the flush mounted insert with your hands See separate operating manual of the control element 2 Turn the operating mode selector adjusting wheel to the desired operating mode The selected operating mode becomes active immediately 3 Re attach the control element to the flush mounted insert Operating Instructions 1473 1 8162 15 Operating Instructions Busch Jalousiecontrol II Operation 7 2 Operation in connection with other devices The operation of the blind depends on the control element used and the use of the sensors When the control element is attached the insert recognizes it automatically 7 2 1 Operation via control element 6430 When operating mode N or M is set Button Function Actuation Result Brief press of the button SN Blind UP The blind travels to the top or bottom end position A renewed brief press of the button stops the blind immediately NV Blind DOWN Long button press The blind tr
16. o Fig 3 Extension unit inputs with connected sensors Setup and function Group and central controls can be implemented via the connection of the 230 V extension unit inputs 1 and 2 In case of group and central controls any number of local control points can be joined and operated from an overriding switching point Additionally it is also possible to connect sensors via the extension unit inputs Operating Instructions 1473 1 8162 Operating Instructions Busch Jalousiecontrol II 4 5 Brightness sensor A brightness sensor can be attached directly to flush mounted insert 6411 U S 101 including sensor connection which is attached to the pane with the aid of a suction cup The values at which a function is triggered can be set individually on the flush mounted insert via a potentiometer and on the comfort timer control element 6455 in the display so that the blind closes at the desired brightness For detailed information see chapter Operation 4 6 Glass break sensor O Note T Setup and function o a pese Fig 4 Connected brightness sensor The glass break sensor can only be used in connection with flush mounted insert 6411 U S 101 Please note that flush mounted insert 6411 U S 101 in connection with the glass break sensor is not suitable as an intrusion or attack alarm since it lacks the required safety against sabotage in accordance with the German VdS Authority on Safety and Security
17. peration from an extension unit or a control element interrupts the sun protection function and manual operation is executed Arenewed activation of the sun protection function is carried out with an UP command 3 minutes travel time or the next bright dark changeover This happens automatically by means of the exterior brightness evening twilight O Note The twilight function is possible only in connection with the timer control element See the relevant operating manual Operating Instructions 1473 1 8162 17 Operating Instructions Busch Jalousiecontrol II Operation 7 2 4 4 Setting for control elements 6430 and 6066 The threshold value of the brightness sensor is set on the adjusting wheel of the flush mounted insert Warning Risk of damaging the device and sustaining injuries When setting or re positioning the brightness sensor the blind may be directly set in motion Keep the travel path of the blind free Setting the threshold value independent of the current brightness 1 Ensure that the brightness sensor is attached to the planned location and is not covered s x 2 Turn the adjusting wheel 1 tothe right if the sun protection function is to be triggered at minimum brightness P tothe left if the sun protection function is to be triggered only at extreme brightness Setting current brightness as threshold value 1 Turn the adjusting wheel 1 to the minimum value right end stop 2 W
18. rein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB Copyright 2012 Busch Jaeger Elektro GmbH All rights reserved O BUSCH JAEGER V 1473 1 8162 Rev 01 17 12 2012
19. times are added and stored O Note ll If an extension unit is installed this can also be used for moving the blind UP and DOWN This makes removing and re attaching the control element during a change of operating mode unnecessary 4 Setthe return travel pulse by moving the blind UP The slats of the blind are adjusted or the roller shutters are moved to the ventilation position via the return travel pulse Before programming a return travel time the DOWN time must amount to at least 10 seconds The return travel pulse starts with the initial UP movement of the blind All subsequent travel times are added during the up movement and subtracted during the DOWN movement and stored as a total return travel pulse The maximum return travel time is 25 seconds Exceeding or dropping below this time is signalled with a stop of the blind 5 Exit operating mode Programming P and set the original operating mode again See chapter Changing the operating mode page 15 Programming is complete Check of programming Preconditions Programming has been carried out correctly The blind is in the upper end position Sequence Ata DOWN command the blind travels down at the programmed DOWN time The blind stops for 0 5 seconds The blind travels back to the top for the time of the programmed return travel pulse If the blind is not in the top end position the DOWN command is carried out without the programmed intermediate position
20. usch Jalousiecontrol Installation and electrical connection 6 2 Mounting in connection with other devices 6 2 1 Mounting with IR control element n combination with IR control element 6066 the installation site must lie within the IR receiving range of 15 m The address of the IR control element is set on number 1 at the factory and can be changed via the address wheel on the rear of the control element Observe the IR receiving range when addressing O Note The IR receiving range may vary due to extraneous light e g sunlight illumination 6 2 2 Mounting with sensors Ifthe connection of a brightness sensor or glass break sensor is planned for flush mounted insert 6411U S 101 consider the factory cable length of 2 m 6 2 3 Mounting with extension units The maximum cable length depends on the permissible ripple voltage of the auxiliary post inputs The ripple voltage however must not exceed 100 V In practice this corresponds to a cable length of at least 100 m To prevent interference from switching processes of the blind drives do not install the motor and extension unit lines in the one cable or close to each other The minimum distance is 5 cm To calculate the maximum number of devices to be operated in parallel in a safety circuit observe the following The current consumption of the motors and the extension unit inputs The power consumption of the flush mounted inserts 6 3 Mounting Warni
21. xtension unit connection Connection of blind motor Adjusting wheel for changing the operating mode Removable cover with shock protection fitted at the factory Terminal block for connecting the brightness sensor glass break sensor Not available on flush mounted Adjusting wheel for setting the threshold value for the brightness sensor insert 6411 U 101 Loop compartment for sensor line o INIA JV N Connection to the control element terminal tower 4 3 Features of function and equipment Suitable for roller shutter blind and awning drives with mechanical or electronic limit switch shut off With two 230 V extension unit inputs Up Down for group control Connection possibility for brightness sensor and glass break sensor 6411 U S 101 With operating mode switch for operating modes Normal Slat Central unit Position Awning only 6411 U S 101 With party function deactivation of the local control station in combination with Busch Blind Control Il control element 6430 6066 Wind alarm cleaning functions can be realised via extension unit input Running time 3 minutes Suitable for polyphase operation Operating Instructions 1473 1 8162 5 Operating Instructions I Il Busch Jalousiecontro 4 4 Extension unit inputs wa A VA pamm P o v HH ES Ore O BrvAus O sme
22. y Wind alarm If voltage is applied to the input the blind travels up and remains up as long as voltage is applied to extension unit input 2 All other operations have equal priority Operating Instructions 1473 1 8162 16 Operating Instructions Busch Jalousiecontrol II Operation 7 2 4 Brightness sensor O Note Brightness sensor 6414 can only be used in connection with flush mounted insert 6411 U S 101 The values at which the sun protection function is triggered can be set individually on the flush mounted insert via a adjusting wheel and on the comfort timer control element in the display so that the blind closes at the desired brightness The sun protection function can be combined with operating modes N and L Prerequisite for faultless function is that the blind can move past the sensor If this is not the case the awning function see operating mode M must be used Procedure The sensor continuously measures the brightness and compares this value with the threshold value Ifthe threshold value exceeds 90 seconds the blind travels down As soon as the downward travelling blind darkens the sensor downward travel is stopped The blind travels up again and stops just above the sensor position The blind travels back to the top end position when the sensor exceeds the set threshold value for more than 15 minutes or a control signal is sent from a control element or an extension unit An o

Download Pdf Manuals

image

Related Search

Related Contents

ABI PRISM® dRhodamine Terminator Cycle Sequencing Ready  1 Pressione  Hypertec N7828AHY User's Manual  Gefen EXT-DVI-FMP video splitter  Fixateur Sol Universel  

Copyright © All rights reserved.
Failed to retrieve file