Operating Instructions Busch-Wächter® 6747-500 AGM
Contents
1. 9 6 2 2 Preparing the 10 6 2 3 1 gt M 11 7 COMMISSIONING er m 13 7 1 Setting limiting the coverage and the detection 13 7 2 Drei line m 14 8 T 15 8 1 2 HH 15 8 2 1 15 8 2 1 Test peration start LE 15 8 2 2 8 2 3 iensun M 8 2 4 09 X 8 2 5 Programming 8 3 Brightness dependent 16 8 4 Programming the device Em 17 8 4 1 Programming th device roter rannte 17 8 4 2 Deleting programmed devices ssie akira apieve dnia ri EE gen mann 18 Operating Instructions 1473 1 8136 2 Operating Instructions Busch Wachter Safety 1 Safety Warning Electric voltage Risk of death and fire due to electrical voltage of 230 V Work on the 230V supply system may only be performed b
2. Operating Instructions Busch Wachter Operation 8 4 Programming the device 8 4 1 Programming the device For programming perform the following steps S Fig 16 Selector switch of the receiver 1 Set the selector switch of receiver 6701 on P LED flashes green 1 2 Fig 17 Programming button 2 Press the programming button on receiver 6701 2 the LED 1 lights permanently green s P ES Fig 18 Set the selector switch on P 3 Setthe selector switch of the Busch Watchdog on P the status LED lights up for approx 10 seconds with a slight delay 4 The devices are being programmed to each other 5 After successful programming the LED starts to flash green again If programming is not successful the LED continues to light up reset the selector switch on the Busch Watchdog to P and repeat the procedure 6 Setthe operating mode of receiver 6701 on R or S or program additional Watchdogs 7 Select the operating mode of the Busch Watchdog on ES or GS Operating Instructions 1473 1 8136 7 Operating Instructions Busch Wachter Operation 8 4 2 Deleting programmed devices Tor delete all programming take the following steps Fig 19 Selector switch of the receiver 1 Set the selector switch of receiver 6701 on E LED flashes red 1 2 Fig 20 Programming button 2 Press the programming button on receiver 6701 2 the LED 1 lights permanently r
3. To protect the device against unauthorized opening screw the enclosed screw into the bottom of the device Operating Instructions 1473 1 8136 42 Operating Instructions Busch W chter Commissioning Commissioning 7 1 Setting limiting the coverage and the detection range Caution Risk of damaging the device The lens of the device is sensitive and can easily sustain damage Do not press on the lens when setting the device Use the following steps to set the coverage and the detection range Fig 6 Adjusting the lateral detection range 1 Adjust the lateral detection range by turning the head of the device Fig 7 Adjusting the coverage 2 Adjust the coverage by lifting or lowering the head of the device The minimum coverage is 6 m Operating Instructions 1473 1 8136 3 Operating Instructions Busch W chter Commissioning IT Fig 8 Adjusting the detection range by masking 3 The range can be specifically limited by gluing on the enclosed foil Cut the enclosed foil to the size required The coverage and the detection range are set 7 2 Activation test The activation test can also be triggered via the service remote control see separate operating manual T 8B A Fig 9 Activation test To carry out the activation test perform the following steps 1 Set selector switch to T S The device is now in test m
4. if installed 2 Press in clamps 2 5 on the sides of the housing with a suitable tool 3 Carefully remove the front of the device Fig 5 Opening the water drain Depending on where the device is installed the water drain may have to be opened e Todo this pierce the plastic membrane on the bottom of the device The installation is prepared Operating Instructions 1473 1 8136 10 Operating Instructions Busch Wachter Installation and electrical connection 6 2 3 Mounting steps 1 Mount the device to the wall N e IDOR SL Do not use countersunk head screws for mounting 26 5 mm 8 5 mm to the wall Use screws with a head diameter of 6 5 mm 8 5 2 mm 23 5 s 3 9 mm 2 Open the battery compartment Insert the enclosed type AAA batteries Pay particular attention to the battery poles a O Note Do not use zinc carbon batteries as replacement Operating Instructions 1473 1 8136 si Operating Instructions Busch Wachter Installation and electrical connection 3 Mount the upper part of the device The bolting dimensions of the base may be compatible with existing bores on older versions of the Busch Watchdog Latch the upper part of the device onto the base 4 To protect the device against unauthorized opening the enclosed screw can be used on the bottom of the device
5. 1473 1 8136 Rev 01 11 2012 6747 500 AGM 220 WaveLINE EIU Power and productivity AB for a better world FR HP ap Operating Instructions Busch W chter 1 STE E E A E E T rien E S LU 3 2 lg HUI ET a e E E 3 3 a a EL ELE 3 4 DEOS 4 4 1 Features of function and 2 1 desea done 4 42 5 4 2 1 Overview of the detection 2 1 1 iaiaaeaia lee Poen Ene nae ede tendria 5 4 2 2 Infrared rasrceee e 5 4 2 3 Limitation of the detection range ciii tieene eise ernennen a domne dada sanie Ee d ipaa 5 4 3 Radio transmission coverage pietre ei irte Y eB eg e HERE ENSE EU HIA Eo ann ET RUPEE indie benennen 6 5 Mechnicaldata TE 7 6 Installation and electrical COMMECUOM 4 2 2 Rear ine 8 6 1 Isequiremerits for the electrician u en ea anne 8 6 2 ERREUR 9 6 2 1 Installati n 2
6. 20 WaveLINE z B 6701 max 100 m Fig 2 Radio transmission coverage The values below are guideline values and may vary depending on local conditions Material surface Guideline values Direct visual connection Approx 100 Walls ceilings and similar obstacles reduce the radio transmission coverage The following approximate values can be expected Material surface Guideline values Wood plaster uncoated glass 70 100 96 Bricks chipboard 65 95 96 Reinforced concrete 10 90 96 Metal aluminium lamination 0 10 96 Fire walls lift wells staircases and supply areas are considered as separating walls just like the installation of the receiver in metal housings The distance between the transmitter and the receiver and from other transmitters that also emit high frequency signals e g computers audio and video systems should be 1 0 m minimum Operating Instructions 1473 1 8136 6 Operating Instructions Busch Wachter Technical data 5 Technical data Designation Value Power supply IEC FRO3 192 AAA 1 5 V IEC LRO3 AAA 1 5 V Horizontal detection 220 Twilight sensor 0 5 300 lux Maximum coverage installed 2 5 m high 16m Radio control range free field 100 m Transmitter frequency 868 3 MHZ Forced switch off min 180 Operating temperature 25 55 C Protection type IP 55 O Inform
7. ation for the connection of ballasts Please observe the following points regarding high inrush currents for ballasts The ballast manufacturer s specification determines the possible number of ballasts Operating Instructions 1473 1 8136 Operating Instructions Busch Wachter Installation and electrical connection 6 Installation and electrical connection Warning Electric voltage Risk of death due to electrical voltage of 230 V during short circuit in the low voltage line Low voltage and 230 V lines must not be installed together in a flush mounted socket 6 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the user of the electrical system ncorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect from power 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth and short circuit 5 Cover or barricade adjacent live parts Use suitable personal protective clothing Use only suitable tools and measuring devices e Check the supply network type TN system IT system TT system to secure the following power supply conditions
8. classic connection to ground protective earthing necessary additional measures etc Operating Instructions 1473 1 8136 8 Operating Instructions Busch Wachter Installation and electrical connection 6 2 Mounting Warning Electric voltage Risk of death and fire due to electrical voltage of 230 V Work on the 230V supply system may only be performed by authorised electricians Disconnect the mains power supply prior to installation and or disassembly Caution Risk of damaging the device The lens of the device is sensitive and can easily sustain damage Do not press on the lens when opening or closing the device 6 2 1 Installation sites Fig 3 Installation sites AN Ceiling mounting in narrow rooms is not recommended mounting height of the device should be between 1 7 m and 2 5 m The distance between light and movement detector should be at least 1 5 m For optimum detection of persons the approach into the detection range should always be offset and never frontal Operating Instructions 1473 1 8136 Operating Instructions Busch Wachter Installation and electrical connection 6 2 2 Preparing the installation To prepare the installation of the device perform the following steps Fig 4 Preparing the installation No Function 1 Locking screw 27 079 Clamps 1 Remove the locking screw 1
9. ed P ES Fig 21 Set the selector switch on P 3 Setthe selector switch of the Busch Watchdog on P the status LED lights up for approx 10 seconds with a slight delay 4 The link will be deleted 5 After a successful deleting process the LED starts to flash red again If the deleting procedure is not successful the LED continues to light up reset the selector switch on the Busch Watchdog to E again and repeat the procedure 6 Setthe operating mode of receiver 6701 on R or S or program additional Watchdogs 7 Select the operating mode of the Busch Watchdog on ES or GS Operating Instructions 1473 1 8136 18 Operating Instructions Busch Wachter Operation Operating Instructions 1473 1 8136 19 Operating Instructions Busch Wachter A member of the ABB Group Busch Jaeger Elektro GmbH PO box 58505 L denscheid Freisenbergstra e 2 58513 L denscheid Germany www BUSCH JAEGER com info bje de abb com Central sales service Phone 49 0 2351 956 1600 Fax 49 0 2351 956 1700 Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and il
10. lights up for approx 10 seconds If the LED flashes the voltage is too low Please replace the batteries After 30 seconds the device automatically returns to the basic setting Set the desired operating mode GS or ES Operating Instructions 1473 1 8136 45 Operating Instructions Busch Wachter Operation 8 2 3 Group mode TB s P ES Fig 13 Group mode If persons move in the detection area switching signals will be transmitted The brightness limit value can freely selected The switch off delay has to be set via the actuator receiver In this operating mode several watchdogs and actuators can communicate with each other 8 2 4 Single mode TB 5 Fig 14 Single mode If persons move in the detection area switching signals will be transmitted The brightness limit value can freely selected The switch off delay is fixed to 3 minutes The switch off delay of the receiver e g 6701 must be set to a value gt 3 minutes In this operating mode only one watchdog can send signals to a specific actuator 8 2 5 Programming T B ss P ES Fig 15 Programming O Note The individual programming steps are contained in chapter 8 4 Programming devices on page 17 8 3 Brightness dependent switching Icon Function xt Switching during all brightness levels Switching during advancing twilight Switching during darkness Operating Instructions 1473 1 8136 36
11. lustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB CopyrightO 2012 Busch Jaeger Elektro GmbH All rights reserved Power and productivity for a better world EB 1473 1 8136 Rev 01 11 2012
12. ode for 10 minutes daytime operation switch off delay 2 sec In addition each detection is indicated by the status LED flashing quickly The device then switches back to the basic setting 2 To carry out an additional activation test set the selector switch back to position T or interrupt the operating voltage supply for more than 15 seconds The device is now in test mode for another 10 minutes Test mode is exited automatically after 10 minutes or by adjusting the brightness The activation test has been carried out Operating Instructions 1473 1 8136 Operating Instructions Busch Wachter Operation 8 Operation 8 1 Control elements Fig 10 Control elements No Function 1 LED Flashes fast detection in test mode Flashes 3 times detection in standard and normal operation 2 Lens 3 Trim potentiometer for brightness value 4 Trim potentiometer for operating mode 5 Screw for dismantling safety 8 2 Operation mode 8 2 1 Test operation for start up T B ES Fig 11 Test operation After 10 minutes the device automatically returns to the basic setting GS operating mode Set the desired operating mode GS or ES O After activating the mains supply voltage the device remains in test mode for 10 minutes see chapter Activation test 8 2 2 Battery test T B P ES Fig 12 Battery test If the battery voltage is sufficient the LED pos 1
13. rs which switch loads via the KNX bus when sources of heat move within its detection range Busch Watchdog is not an intrusion or attack alarm 4 1 Features of function and equipment Coverage of 16 m e Radio transmission in the detection range Battery operation for line independent installation e Cableless retrofitting e Detection and status indication Battery test Operating Instructions 1473 1 8136 Operating Instructions Busch Wachter Setup and function 4 2 Detection ranges 4 2 1 Overview of the detection ranges 4 2 2 Infrared range 220 g N 1 16 m Fig 1 Infrared range Detection range The detection range is 220 and the coverage is 16 m Ceiling mounting movement detector offers optimum surveillance if mounted to the ceiling at a maximum height of 2 5 m 4 2 3 Limitation of the detection range The horizontal detection range of the Busch Watchdog is 220 The detection range can be limited in case of special local circumstances To do this proceed as follows 1 Cutthe included adhesive film to the desired length 2 Glue the section of covering foil from the front onto the area of the sensor of your Busch Watchdog where the detection is to be blocked out O Note For an illustration see chapter 7 1 on page 13 Operating Instructions 1473 1 8136 5 Operating Instructions Busch Wachter Setup and function 4 3 Radio transmission coverage 2
14. y authorised electricians Disconnect the mains power supply prior to installation and or disassembly 2 Intended use The device is to be used exclusively with the components that are supplied and licensed as described in chapter Setup and function 3 Environment Consider the protection of the environment Used electric and electronic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting depot All packaging materials and devices bear the markings and test seals for proper disposal Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies The products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EC WEEE and 2002 95 EC RoHS EU REACH ordinance and law for the implementation of the ordinance EC No 1907 2006 Operating Instructions 1473 1 8136 3 Operating Instructions Busch Wachter Setup and function 4 Setup and function The Busch Watchdog 220 WaveLINE is a versatile cableless movement detector with a 220 detection range and is suitable for application on properties without a clear overview and for mounting to walls and ceilings The Busch Watchdogs are passive infrared movement detecto
Download Pdf Manuals
Related Search
Related Contents
Jabra BTE4 Bluetooth Headset User Manual Conceptronic 5 Port USB 2.0 PCI Card 操作方法及び判定方法 USER MANUAL Sea Gull Lighting 65190-07 Installation Guide Manuale Jeko - Nobil Curtis LCD3718A User's Manual taxe modemploi particuliers.pub Statuts et règlements - Syndicat du personnel de soutien du cégep 19238-6NL-04 PNOZ X2, PNOZ X2.1, PNOZ X2.2 Copyright © All rights reserved.