Installation and Operating Instructions Door Station Stainless
Contents
1. 1 Insert the locking plate flushly into the panel box i Insert locking plate evenly The locking plate must not be twisted while being installed into the panel box and must not be under tension Push the locking plate inwards until the plastic brackets touch the wall 2 Fasten the locking plate with the 4 Allen bolts and locking washers included In order to guarantee a secure fastening of the front panel later the Allen bolts must be firmly tightened 3 Fold out both lateral mounting retainers 1 slide the front panel of the Door Station Stainless Steel into the mounting retainers 2 and attach the catch strap of the front panel to the hook of the locking plate 3 4 Connect the 2 wire bus to the BUS terminals i Jumpers between BUS and ZV The wire jumpers between BUS and ZV are required for operation of the colour camera Thus the illumina tion of the call buttons at the door station cannot be switched off If an external power supply is con nected to the ZV terminals the jumpers must be removed 5 Pull the front panel from the mounting retainers 1 and fold these in 2 6 Position the lower fastening bolt s of the front panel to Close 7 Mount the front panel onto the guide bolts and press it on until the upper and lower fastening bolts engage
2. Start up Once all of the devices door and home stations control device etc have been installed the door communication system can be started up Start up a door station is described in the system manual included with the control device Multi function input y A mechanical push button can be connected to the multi function input L7 of the stainless steel door station s built in loudspeaker via the included connec tion cable The push button then has the same function as a call but ton and can therefore be used for example as a call but ton or for controlling a switching actuator TNL Setting range of coverage of colour camera oUo Remove the colour camera from the back of the front panel of the Door Station Stainless Steel Loosen both screws of the attachment profile for this purpose Remove the camera cover plate from the demounted colour camera Slightly loosen both Torx screws to the left and right of the camera lens i Do not take out the screws completely When adjusting the lens carrier it is sufficient to slightly loosen the screws Do not take out the screws completely from their brackets 4 Set the camera lens in the desired direction
3. For testing purposes install the colour camera in the front panel and check on the TFT display of the con nected home station whether the set angle of the camera lens is adjusted properly and whether the view of the person in front of the door is optimal Remove the colour camera again and lock the lens carrier by tightening both Torx screws Mount the camera cover plate Mount the camera into the front panel of the Door Station Stainless Steel and fasten it Ensure proper seating of the black seal Opening of Door Station Stainless Steel The included opening tool is required for opening the Door Station Stainless Steel 1 Turn the lower fastening bolt s with the opening tool to Open Single column door stations have one lower fasten ing bolt double column door stations have two on lower fastening bolts The position of the fastening bolts is shown via small YY 30 1 recesses on the lower side of the front panel Open A Take care with plastered walls With repeated opening of the door station with plastered walls the opening tool may damage the plaster 2 Lift the front panel from the lower attachment 1 and pull it at an angle downwards from the upper E3 attachment retainers 2 B m Replacing inscription label Inscription labels For labelling the Gira Door Station Stainless S
4. the front The best installation site of an external light source is above the colour camera Installation height The recommended installation height of the colour camera is 1 50 m At this installation height people with an average height of 1 80 m are optimally pre sented The minimum installation height is 1 20 m Installing panel box max 20 mm IN Attention Installation and mounting of electrical devices may only be carried out by a qualified electrician 1 Select a suitable installation site and chisel an open ing in the wall 2 If necessary mount the included wall anchor Note the following information when mounting the panel box e Ensure installation position is correct Note the TOP labelling The panel box must be installed level With the later mounting of the Door Station Stainless Steel there is no possibility for correction The panel box must be installed as flush to the surface as possible It must be ensured that the locking plate can be flush mounted later Maximum plaster compensation is 20 mm 3 Plaster in the panel box to be flush with the final sur face maximum plaster compensation 20 mm 4 Mount the included plaster protection 5 Plaster the wall 6 Carefully remove the plaster and take out the plas ter protection Installing front panel
5. Installation and Operating Instructions Door Station Stainless Steel Video 2551 20 2552 20 2553 20 2554 20 2556 20 2558 20 RA 2559 20 2560 20 2562 20 Table of contents Device deseription a eed tri eet t rd x i te erect idet bn dave halten d 5 Functiori cange or the colour camera iine edle ea eee 6 Coverage range of the colour camera ssssssssssssssss eene errem 6 Sel amp ctiorixof the installati n SItex ir e He e cp eee be E aces 7 Installing parelibOXsS zs ds o m o soie ya DN MN ditis ist 8 Installingitont pci au US DP HER ERR RBRUM 0 NIIT 1 M lti f rictlonnputz us A e biet te ue e i Mri e OO 11 Setting coverage range of the colour camera ssssssssssssss en 2 Opening Door Station Stainless Steelseries insi a E enne 3 REPlACINGPINSCHPTIOMNA DE late bet en etch te see peu ent oud oa dens eMe tester at 4 Irun 6 Technical aa es ran elek 7 A AAA um eos Mb O Aa rs Si da JANE oe Ae les 8 Device description The Door Station Stainless Steel Video is a pre assembled vandalism protected door sta tion with colour camera for the Gira door communication system The front plate of high quality V2A stainless steel with a thickness of 3 mm is especially robust The call buttons are also made of durable stainless steel The illuminated inscrip tion labels are covered by a fully secured and flameproof glass plate The inscription labels can be opened via a covered mechanism and can then removed from the f
6. he Systemprogr button on the control device to exit the programming mode Press the call button to trigger a call tone at the assigned home station The button press is confirmed by an additional acknowledge ment tone If the conversation is accepted by the home station the micro phone opening is illuminated blue Switching light on in conjunction with a switching actuator Licht T amp Press the call button to switch on light or another device via an assigned switching actuator The button press is confirmed by an additional acknowledge ment tone Technical data Connections Power supply Protection type Operating temperature Dimensions W x H x D 1 gang 2 gang 3 gang 4 gang 6 gang 8 gang 9 gang 10 gang 12 gang Camera installation height Min height Recommended installation height Image capture element Wide angle objective Visible detection range Detectable area Colour system Pixels Horizontal resolution Switching threshold colour to B W operation Light sensitivity in B W operation Electronic shutter close time 2 screw terminals for 2 wire bus 2 screw terminals for additional supply 2 system bus connector strips 6 pole 1 video connector strip 2 pole 2 sabotage contact screw terminals 2 cameras via video control device 3 and 4th camera via external additional supply 24 V DC IP 44 25 C to 70 C 140 x 265 x 60 mm panel b
7. ox 160 x 285 x 3 mm front panel 140 x 332 x 60 mm panel box 160 x 352 x 3 mm front panel 140 x 417 x 60 mm panel box 160 x 437 x 3 mm front panel 250 x 265 x 60 mm panel box 270 x 285 x 3 mm front panel 1 20 m 1 50 m CCD sensor 1 3 150 aperture angle 100 angle of detection of the camera 140 with 20 swivelling PAL 500 H x 582 V 380 TV lines 1 Lux 0 1 Lux up to 1 100000 s Warranty The warranty is provided in accordance with statutory requirements via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center Gira Giersiepen GmbH amp Co KG Elektro Installations Systeme Postfach 1220 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de GIRA 10410925 20 11
8. r view Camera cover plate The splash water resistant camera cover plate made of shock resistant plastic can be easily replaced if damaged for example by vandalism Setting coverage range of the colour camera The CCD sensor element of the colour camera has an angle of detection of 100 If this angle of detection is not sufficient for the required installation scenario the area can be manually swivelled by 20 in all directions Haust r i Haust r Coverage range of camera with Coverage range of camera when lens is perpendicular lens swivelled by 20 Selecting the installation site The selection of the installation site and good illumination are critical for good picture quality No backlighting Do not point the colour camera towards strong backlighting such as streetlamps or yard illumination Prevent strong sunlight from hitting the lens Picture background Avoid pointing the camera towards extremely bright image backgrounds and back grounds with strong contrasts Lighting LEDs integrated in the camera provide an even illumination of the field of view in dark ness i Black and white mode in poor lighting conditions In poor lighting conditions 1 lux or with the field of view illumination switched on the colour camera provides black and white pictures only If the entry area is equipped with additional illumination this light source must not shine directly into the camera lens from
9. ront Both the call buttons and inscription labels are uniformly illuminated with a white power saving LED element Loudspeaker and microphone are located behind the respective sound openings and are water resistant and vandal proof Wall anchors included Panel box Locking plate 4 Plastic bracket Catch strap hook Front panel Colour camera Loudspeaker cover icrophone ame plates Call buttons 000XJ0042a0N Function range of the colour camera The colour camera of the flush mounted door station has the following product features Automatic day night switching The camera switches from daytime mode colour presentation to night mode black and white presentation and back again at an ambient brightness of 1 Lux Due to the high degree of light sensitivity in night mode good presentation results are achieved even with poor lighting conditions to 0 1 Lux In night mode the integrated white LEDs ensure an even illumination of the field of view Large coverage range The colour camera can be swivelled manually by 20 horizontally and vertically during start up A very large field of view in the door entry area results in conjunction with the 00 range of coverage of the camera Camera heating The integrated temperature dependent camera heating prevents condensation from orming on the camera cover plate due to fluctuating climactic conditions and thus provides a clea
10. teel use only Gira inscription labels The transparent plastic labels are non fading weather resistant and wrinkle free With the included release code inscription labels for the first labelling are available free at www marking gira com 1 Unlock the call button with the enclosed plastic key twist the plastic key anti clockwise until it engages 2 Engage the call button press the call button firmly inwards by c 1 cm v The call button engages and stays in the pressed position 3 Grip under the glass cover with the flat side of the plastic key and twist out the inscription label carrier A Do not remove the inscription label carrier Do not lift and remove the inscription label carrier 4 Remove the existing inscription label and slide the new inscription label into the inscription label carrier until it stops 5 Position the inscription label underneath the clips of the inscription label carrier 6 Slide in the inscription label carrier again At the same time position the inscription label with your finger E 7 Release the call button To do this press in the plastic key slightly and turn it clockwise until the call button is released from the lower position 8 Lock the call button To do this turn the plastic key clockwise again until it engages 9 For function
11. test press the call button the call button is correctly locked when the call button cannot be pressed in deeply and an acknowledgement signal is heard when the call button is pressed If the call button is not correctly locked please repeat step 8 Operation Volume setting SER po E 3s EX Systemprogr 2 1x M Meier Sl 3 o gt ja 4 1x M Meier p Y ds ul B 5 BE 6 1x10 Systemprogr eed Pi Initiating a call ringing M Meier Y 1 Nu The volume can be set separately at each door station The volume setting must be made by two people Press the Systemprogr button on the control device for 3 sec to start programming mode Briefly press a previously assigned call button at the door station The second person accepts the door call at the home station via receiver or speech button and starts speaking Briefly press the call button again at the door station Volume changes during the voice connection when the button is pressed There are four volume levels in total The next highest volume is set with each press of the button When the loudest volume level is reached the next press of the button sets the quietest volume level Ending the voice connection The most recently set volume level is saved in the door sta tion Briefly press t
Download Pdf Manuals
Related Search
Related Contents
Manual de Instruções Dynex 3-Port Quick Setup Guide 2 - University of Phoenix Philips DVP3350V Direct Dubbing Progressive Scan DVD/VCR Player 在宅酸素療法における火気の取扱いについて Instructions for Use • OWNER'S MANUAL • MANUEL D'INSTALLATION Varta Power Line 17626 MT400A User Manual 11 Copyright © All rights reserved.