1. Unscrew the knurled knob 11 Withdraw the milling spindle Turn the chuck lever 8 as far as possible to the right open Unscrew the union nut 18 completely if necessary use a 2 35 mm diameter 20 tungsten carbide cutter shank and pull the milling spindle off the motor Use a No 4115 chuck wrench to jerk the chuck 24 anti clockwise and unscrew it completely If necessary hold the tongue 21 on the motor with a No 4113 wrench Please note In the chuck is a stroke for short shafts this could be removed or replaced as required Grease the chuck 24 lightly and insert it into the shaft Use the wrenches as described previously to screw the chuck in clockwise Screw it in as far as possible and then tigthen it slightly Prior to inserting the chuck clean it and the shaft thoroughly as otherwise the concentricity may be adversely affected Press the milling spindle onto the motor and tighten the union nut 18 Insert the milling spindle into the holder and tighten the knurled screw 11 411482 35mm 4117 O3 00mm stroke for pins 4918 2 35mm stroke for pins 4925 3 00mm 5 Maintenance and Care Caution Do not use compressed air to clean the milling spindle The chuck should be cleaned and re greased once in a while depending on how dirty it is reter to section 4 Replacing the Carbon Brushes Unscrew the cover 30 trom the moto
2. Rated trequenzy 50 60 Hz Motor torque 3 6Ncm Speedrange 1 000 30 000rpm Concentricity chuck lt 0 015mm Subjet to technical modification without prior notice Q2 35mm series O3 0mm on request milling machine Control unit Width 200mm Width 185mm Height 320mm Height 68mm Depth 225mm Depth 180mm Weight 2 5kg Weight 2 5kg 8 SCHICK Milling machine S1 17b optional Measuring Spindle ae vr 2250 9 Accessory S1 Separator ar no 2655 Milling tray Art no 2507 Diamond tool set Turbine 1 6 mm 8 pcs Art No 2660 ke t Coordinat table Light head for turbine Adaptor ring Au uo 2508 Polish set 2 35 mm Art no 2505 Art No 2510 1 3 PCS Art No 2665 gt d ae gi bra Ay Fa I 8 7 mi i Adjustable angle Control for light head Holding tray Art No 2509 Milling set 2 35 mm Art no 2506 Art No 2480 7 PCS Art No 2530 A ze y yt measuring spindle ar no2250 light head short an no 2510 2 Suction tube ar no 2470 S1 Wooden Base A ve 2400 Junior P Control unit cpl Art No 2409 control box Art No 2406 we J motor with milling spindle complete Art No 4100 05 S1 Ceramic Milling Set cpl Art No 2650 11 without S1 Junior and S1 Wooden Base turbine Art No 2640 1 holding clip Art No 2245 light head for turbine Art No 2510 1 control for light head Art No 2480 cable for light head Art No 2485 suction tube Art
3. the clamping knob 13 should be unlocked for drilling by pulling down the motor a vertical movement of the rig can be carried out The maximum vertical distance of the rig is 24mm Should the clamping knob 13 be locked whilst the rig is being moved vertically the milling spindle will be locked at this level The knurled knob 7 is a depth stop and can be adjusted individually about the metric thread around the same drilling depths to repeat the jointed arm can be moved both horizontally and vertically if clamping levers 9 and 10 are unlocked 3 7 Tightening the milling spindle of the motor exchanging the rotary instrument The motor must be switched off before exchanging the rotary instrument turn the chuck lever 8 as far as possible to the right open and insert the instrument turn the chuck lever 8 as tar as possible to the lett close to tigthen the instrument into place turning the chuck lever 8 approximately half way to the right open prevents the milling spindle rotating yet grips the instrument securely This position is intended for gripping a trimming instrument 3 Setting up Operating the unit exchanging the rotary instruments 3 8 Surveying spindle Unscrew the knurled knob 11 Withdraw the milling spindle Insert the surveying spindle 17a or optional 17a into milling spindle holder and tighten the knurled knob 11 4 Replacing the chuck
4. No 2470 separator Art No 2655 model table Art No 2407 9 diamond tool set for turbine 1 6mm 8pcs Art No 2660 polish set 2 35mm 3pcs Art No 2665 10 Declaration of Conformity We GEORG SCHICK DENTAL GmbH Lehenkreuzweg 12 D 88433 Schemmerhofen A declare herewith that the product milling machine S1 2405 und 2409 is in conformity with the following provisions of Directive 2001 95 EG general product safety 2006 42 EG machinery directive 2006 95 EG low voltage directive 2004 108 EG EMV directive Name and adress of Woltgang Schick person in charge Lehenkreuzweg 12 88433 Schemmerhofen Schemmerhofen im April 2010 S258 W Schick Gesch ftsf hrer 08 11 bg Dentalger te Georg Schick Dental GmbH Lehenkreuzweg 12 D 88433 Schemmerhofen Telefon 49 7356 9500 0 Telefax 49 7356 9500 95 E Mail info schick dental de Internet www schick dental de D20544
5. ck and prolong ist service life it must always be fitted with a rotary instrument or the rod supplied with the unit even when not in use 2 6 Recycling R WEEE Reg Nr DE 78620387 a Caution When using rotary instruments do not exceed the maximum speeds laid down by their manufacturer repairs and other technical procedures must only be carried out by SCHICK or other suitable qualitied personnel authorized by SCHICK SCHICK do not guarantee the 1 milling machine should it not have been used in accordance with the operating instructions 3 Setting up Operating the unit exchanging the rotary instruments 3 1 Ascertain that your mains supply coincides with the data on the rating plate 3 2 Plug the unit into a mains socket 3 3 Operating the unit compare page 7 switch the main supply on 1 place the model table 5 on the platform 6 turn the eccentric lever 2 to lock the model table into position move switch 3 to set the milling spindle to clockwise or anti clockwise rotation the control knob 4 is used to select stepless the rom 3 4 Vertical adjustment of the jointed arm grip the jointed arm unlock the knurled knob 12 and position the arm as required Lock the knurled knob 12 3 5 Securing the jointed arm in position the jointed arm can be locked into place as required by locking or unlocking the clamping levers 9 and 10 3 6 Working with the vertical rig
6. e SCHICK LDentalgerate Georg Schick Dental GmbH Lehenkreuzweg 12 D 88433 Schemmerhofen Telefon 49 7356 9500 0 Telefax 49 7356 9500 95 E Mail info schick dental de Internet www schick dental de l l S7 i 1 d l O TE ha i i Ae RK Original Operating Instructions SCHICK Milling Machine S1 SCHICK Milling Machine S1 Index 1 Range of Applications 2 General intormations Caution A Setting up operating the unit exchanging the rotary instruments Replacing the chuck Maintenance and care Replacing the carbon brushes Possibel Faults Technical Data Milling Machine S1 Accesory O Decleration of Conformity SE O OND 1 Range of Applications The S1 milling machine is intended for use in dental laboratories It includes a milling arm which is easily moved in three dimensions This milling machine can be used for the materials usually employed in dental laboratories such as waxes plasters acrylics metal etc 2 General Information 2 1 Ascertain that your mains supply coincides with the data on the rating plate 2 2 S1 milling machines are not suitable for the following applications in areas where there is a risk of explosion 2 3 Ensure that all regulatory requirements are observed during use always wear protective glasses 2 4 Under no circumstances should the milling machine be cleaned with compressed alr 2 5 To retain the precision of the chu
7. r and pull it back Pull on the cord to remove the insert Use your fingers to rotate the retaining springs 31 as far as possible in the direction of the arrow Remove the old carbon brushes Insert the new brushes ensuring that the lugs 33 on the carbon brushes fit into the apertures 34 Do not bend the lugs The strands 35 of the brushes must remain exposed Use your fingers to rotate the retaining springs 31 as far as possible over the brushes Replace the insert with the cord can only be fitted in one position Screw the cover 30 back into place ensuring that the cord does not become twisted 34 f 4172 carbon brush f Re E 30 JI fe 35 32 dn e R S hr 33 6 Possible faults Should the milling spindle be overloaded or jammed for savety reasons the unit switches itself off To continue operating the unit switch it OFF and ON again switch 1 Should the unit overheat the excess current cut out on the back of the controller is activated Once the unit has resumed ist normal working temperature the pin can be pressed in and the unit will run again at the previously set speed Should the pin pop out repeatedly whilst the unit is in operation the unit is defective Should the power decrease of the motor run jerkily check the carbon brushes If necessary replace them 7 Technical data Technical daten S1 Junior Rated voltage 230V 115V 100V