Home
OPERATING INSTRUCTIONS
Contents
1. For work under voltage only approved tools may be used To avoid an electrical shock don t touch directly the output of the power supplies output sockets clamps The leads used must be sufficiently insulated and have sufficient voltage stability and the contacts have to be shockproof safety sockets Do not lay metallic bare cables and contacts All these spots have to be covered with suitable flameresistant insulation material or other measures to protect them against direct contact Protect all electric conductors of the connected consumers against direct contact If there are doubts whether a safe usage is still possible the power supply unit has to be put out of operation and be secured against unintentional use It must be assumed that a safe usage is still possible if e the power supply shows visible damage e the unit does not work and e after longterm storage under unfavourable conditions after transport strain 3 Operational Elements See Page No 9 for figure 1 Front Panel 2 Connection clamps red blue and grounding yellow green 3 Power switch ON OFF on the rear panel of the unit 4 Controll LED s for voltage 4a current limitation 4b and over heating 4c 5 Control knob to adjust fine voltage 5a Control knob for coarse voltage adjustment 6 Control knob to adjust current limitation 7 Analog display for DC voltage and current 8 Volt Amper meter selection toggle switch 9 Fuse holder
2. 100 recy cling paper Bleached without chlorine Imprint These operating instructions are published by Conrad Electronic GmbH Klaus Conrad Str 1 92240 Hirschau Germany No reproduction including translation is permitted in whole or part e g Photo copy microfilming or storage in electronic data processing equipment without the express written consent of the publisher The operating instructions reflect the current technical specifications at time of print We reserve the right to change the technical or physical specifications Copyright 1997 by Conrad Electronic GmbH Printed in Germany OPERATING INSTRUCTIONS Power Supply PS 302A Item No 51 1412 Power Supply PS 302A Attention Read before operation Read the manual carefully and completely Inthe case of damage caused by non observance of the instruction the claims under guarantee lapse We cannot take any liability for consequential damage Please read and understand the instructions before attempting to use the power supply Warning Operation as directed means This product is only constructed for connection to an operating voltage between 0 and 30 VDC at the output terminals The power consumption of the connected device must not exceed 2A If this current is exceeded the power supply is overloaded It is not allowed to operate the power supply in damp environments or outdoors according to the safety regulations Contents 1
3. on the rear panel of the unit 10 Mains connection for a appliance plug not contained in delivery 11 Heatsink 4 Operation a Connection Connect the earthing contact plug of the power supply with a earthing contact outlet First make shure nothing is connected to the output ter minals then switch on the power supply with the power switch Attention During long time operation with a nominal load 30 V 2 A or if there are short circuits The heatsinks are getting hot Attention Danger of burning Always pay attention to sufficient ventilation of the power supply and never cover the ventilating slots on the top and the bottom of the cabi net to avoid damage As soon as the LED indicates thermal overload separate the connected user s from the power supply As soon as the LED is off the power supply can be used again after cooling off If you connect a consumer always pay attention that it is not switched on If you connect a user which is switched on to the output clamps of the power supply sparks might be produced which might damage the connection sockets and or the connected leads and or the clamps b Adjustment of voltage unloaded output First turn the panel control knob for the current limitation 6 to the right clockwise until the LED for the current limitation 4b is off At the same moment the LED for voltage adjustment goes on 4a Now you can select the desired output voltage The output of the powe
4. Introduction ze ars e a a 2 2 Safety Rules Mains connection and exchange of fuses 3 3 Operational Elements uesesenseeenenennenennnnen teeta eset en enone 6 4 Operation a re Herne 6 5 Technical Data cui ee ihr 8 1 Introduction This power supply is infinitely variable for voltage and current and can be universally used for school work and hobby etc 2 11 10 An electronic current limiter protects the power supply against overload or a short circuit at the output a thermo fuse interrupts the load circuit output when the max temperature is exceeded gt 120 C in this case the LED for TEMP is on After cooling off again the LED goes off the output is restored in circuit again If there is an overload short circuit or overload the output is turned off that means the current at the output is more than the preset current limit The output voltage remaining at the terminals is only a few mV When the short circuit is removed the output is restored The red LED displays the limiting condition U or The preset values can be read in a common analog meter using Volt Ampere toggle switch Voltage and current is set over 3 setting knobs So an exact setting of the output voltage and output current current limiting is possible 2 Safety Rules 2 1 The power supply is constructed in protection class according to VDE 0411 or VDE 0550 it is equipped with a VDE approved mains cable wit
5. h a protective conductor and may only be connected to 230 V AC electric mains with protective grounding 2 2 Please pay attention that the protective conductor yellow green is connected in the unit and in the mains as there is danger to life if the protective conductor is disconnected Furthermore pay attention that the insulation is neither damaged not destroyed 2 3 Keep power supplies away from children 2 4 Pay attention to the rules for prevention of accidents in industrial enterprises prescribed by the Industrial Trade Associations for electrical installations and production facilities 2 5 When using the power supply in schools and hobby workshops the usage has to be controlled by the responsible teachers or skilled personell 3 2 6 2 7 2 8 2 9 2 10 2 11 2 12 If covers are opened or parts are removed except what is possible without tools voltage carrying components can be exposed Terminals can also carry voltage If it is necessary to open the unit before adjustment maintenance repairing or exchange of parts or modules the power supply has to be disconnected from all voltage sources Repairing or maintenance of the power supply may only be executed by skilled personell who know the dangers and the respective rules VDE 0100 and VDE 0701 Condensers in the unit can still carry voltage even if the unit has been disconnected from all voltage sources Please make sure to use only new fuse of the prope
6. nennnnol Load Regulation for 100 Load Change Ripple at Rated Load Fuse Voltage amp Current Display Weight Dimensions W x H x D Surrounding Temperature Operating Temperature min to max Rel Humidity Barometric pressure 8 230VAC 6 10 50 Hz Max 100VA 0 30 V DC stepless 0 01 2 A max stepless 0 05 lt 10 mV 5 mVeff Slow Blow 1A 250V usually T 1A 250V Analog Panel meter common for voltage and current Selectable by toggle switch approx 4 3 Kg 225 x 135 x 260 mm 5 C 40 C Max 85 not condensing 600 to 100 hPa 2 13 2 14 2 15 2 16 2 17 2 18 2 19 voltages gt 35 VDC hazardous to life are created When operating the power supply pay attention to sufficient ventilation Never cover the ventilating slots Place the unit on a hard flame resistant base Make sure good ventilation of the unit is possible Cooling of the units is mainly achieved by convection heat flow Do not operate charging units and connected loads without supervision Take measures to protect and secure the connected products against operational effects of the power supply e g over voltage failure of the power supply and against effects and dangers orginating from themselves undue high power input In the case of error function power supplies can release voltages more than 50 V DC this is dangerous even if the output voltage of the units is below this value
7. r rating Do not use repaired fuses and do not bridge the fuse holders Pull the plug to change the fuses and separate the soldering station from the mains voltage as otherwise it will be dangerous to life Turn the fuse holder cap to the left with a screwdriver and lift it with the defect fuse from the fuse holder Replace the fuse only with a new one of the same type After the fuse has been changed carefully screw the fuse holder cap with the new fuse into the fuse holder Attention Put the power supply only into operation after the cabinet has been safely closed and screwed together Don t switch on the power supply immediately after bringing it in from a cold to warm room Condensed water might impair or destroy your unit Give the power supply time to warm up to room temperature ithout switching it on When working with power supplies it is not safe to carry metal conductive jewelry necklaces bracelets rings etc It is not allowed to connect power supplies with people and animals If the output of one or more power supplies is connected in series 5 Technical Data Mains input 0 0seeeeeeen Frequency unununnnennenenennnnnn Power consumption Output Voltage Output current Line Regulation Constant Voltage at Mains Change 6 tO 10 concoconcncana
8. r supply is potential free that means not connected with the earthing conductor A potential connection between the power supply and the consumer load is possible via a separate earthing socket between the output sockets and c Adjustment of the current limitation Switch the power supply off and short the output terminals Switch on the power supply The display for the output current shows depending on the setting of the control knob for current limitation any value Set the current limit this means the max current when the power supply should be limiting After the current limit has been set open the short circuit but the power supply must be switched off before otherwise a breaking spark could be produced