Installation- and Operating Instructions
Contents
1. Since an exact temperature control can only be ensured if there is a smooth heat transmission between the temperature sensor and the pool water an osf immersion shell R 1 2 Art No 3200200001 has to be installed in the piping system R 172 We wish you much joy and recreation in your pool Subject to change without notice November 07
2. Page 4 Temperature Control The plug in electronic temperature governor and the temperature sensor are matched and should only both be replaced in case of repair If however a sensor or temperature governor are individually replaced a new alignment has to be carried out by a potentiometer on the insert card If due to an unfavourable location of the temperature sensor the water temperature does not correspond to the requested temperature it can be re aligned by the same potentiometer do not adjust sensor adjustment CENA Ns ie A e mE C oe E Jo Ogea g E CI clililitabils In the standard version the temperature sensor is available with a line length of 1m If required it can be prolonged up to a maximum of 20m with a shielded line cross section min 0 34mm The shielding has to be connected to the terminal 75 Installation of the sensor line near supply mains has to be avoided to rule out possible disturbing influences
3. switch power supply can be continuously adjusted up to 8A Uperating Instructions PFU 4UU ES Page z Technical Data Dimensions 220mm x 219mm x 100mm Operating voltage 400V 50Hz Power consumption of the control system abt 1 5VA max 3 0 kW AC3 Heating max 0 4 kW AC1 Additional output max 0 4 kW AC1 Type of protection IP 40 Installation Capacity Pump For installation the control unit has to be protected against humidity according to its type of protection The power supply of the unit has to be effected by an all pole main switch with a contact gap width of a minimum of 3mm Before opening the housing the unit has to be switched free of electrical tension by all means Electrical connection The electrical connection as well as alignment and service works shall only be carried out by a qualified specialist electrician The following cable arrangement and the corresponding safety instructions in force shall be observed mains 3 N 400v For use of a 400V threephase pump L1 a8 For use of a 230V A C pump L2 K nfi P LcoNtol PC 400 ES D D U1 VI W1 W5KWS5SK Th Th U2 N amp N 2 4 3 5 N 11 12 13 14 15 16 LA dosage SERBS RG ye He aha system potentials filter pump ila aes heating EUROTRONIK 1 level control temperoture mox 400W 400V mox 8A 230V miter mox 400W potential free NR 12 TRS 2 se
4. Installation and Operating Instructions rPee ebicontol CE PC 400 ES Art No 3002700105 Functioning The Mff kilter control system PC 400 ES enables time controlled connection and disconnection of a 400V A C filter pump Setting of the daytime and the individual response times can be noted from the corresponding operating instructions of the automatic switch which is enclosed By means of the selector switch in the front cover it is possible to a switch on and off the functioning of the unit Attention the control system is thus not disconnected from the mains supply at all poles b switch the unit to permanent operation or automatic operation automatic switch of the filter pump Also during the working time of the filter pump the heating of the pool is regulated by the plug in electronic temperature control During interruptions of the filtering process the heating is automatically switched off by the internal locking device A connection facility for a safety temperature limiter of a flow governor ensures additional protection of the heating against overheating The requested temperature of the pool water may be chosen or the heating may be switched off by an adjuster on the front plate Connection terminals for an electronic level control MES NR 12 TRS 2 Art No 3030000020 ensure a comfortable automatic control of the water level in the pool Additionally the filter pump is protected against damage which may arise due t
5. nsor a8 CTH Pee kcontol PC 400 ES D U1 V1 W1 N WSKWSK Th Th U2 N N 2 4 3 5 N 11 12 13 14 15 16 aP RA dosage aie ejl N je N LRUTZ 14 5 Sie N m Mm fiz fis f4 j Windin filter pump PEE Se ak heating EUROTRONIK 1 level control tempercture mox 400W 230V max 8A 230V limiter mox 400W potential free NR 12 TRS 2 sensor Uperating Instructions PU 4UU ES Page 3 The bridge which is installed by the manufacturer between the two terminals designated as Th has to be removed if a safety temperature limiter is connected If the latter is not connected the bridge has to remain in place The bridge which is installed by the manufacturer between the terminals 13 and 14 has to be removed if a level control unit NR 12 TRS 2 is connected If a level control unit is not connected the bridge has to remain bolted between these terminals In this case the terminals 77 and 72 shall not be used The bridge which is installed by the manufacturer between the terminals 3 and 5 has to be removed if an EUROTRONIK 1 is connected If an EUROTRONIK 1 is not connected the bridge between these terminals has to remain in place In this case the terminals 2 and 4 shall not be used Attention Only the EUROTRONIK 1 potential free model from 1994 on shall be used The bridge which is installed by the manufacturer between the terminals designated as WSK has to be removed when connecting
6. o operation of the filter unit without water Connection terminals for an fffXHEUROTRONIK 1 potential free_ model Art No 3104800200 ensure an enlargement of the filter control to an automatic filter and re flushing control A further terminal connection enables the connection of supplementary instruments e g dosage system The terminals D D are potential free and can therefore be individually used During the filtering times the relay point between the terminals D D is closed out of the filtering times this relay contact point is open This contact can be loaded with a tension of a maximum of 230V and a power of a maximum of 400W cos g 1 The connection terminals for the winding earthing contact WSK Wicklungsschutzkontakt ensure connection of a winding earthed switch which is integrated in the motor winding of the filter pump If this contact opens e g due to excessive heating of the motor winding the filter pump and automatically the heating and dosage system are switched off As soon as the winding earthing contact closes after cooling down of the motor winding the units are automatically re activated Manual re setting is not necessary The connection terminals WSK are supplied with 230V Operation of the filter pump and the heating are displayed by the control lamps in the front cover thus a control is possible at any time The filter pump is protected against overloading by a plug in electronic protective motor
7. the winding earthing contact If this contact is not connected it has to remain in place Opening of one of the contacts between the terminals 13 and 74 or 3 and 5 involves an immediate disconnection of the filter pump the dosage system and the heating Closing of one of the contacts between the terminals 2 and 4 or 11 and 12 involves a forced connection of the filter pump The electronic control together with the EUROTRONIK 1 the heating and the level control system are protected by a 3 15A fine wire fuse inside the unit Electronic motor protection M N The threephase filter pump is protected against overloading by a plug in O heating electronic motor protection For this purpose the motor protection has to be set to the nominal current of the filter pump see type plate of the pump If the O filtering nominal current of the filter pump is not known the motor protection can be set according to the following procedure O disturbance 1 Turn adjusting screw of the motor protection clockwise to the stop point Switch on the pump unlocking 3 Turn adjusting screw slowly anticlockwise until the motor protection is triggered and the red trouble signal is flashing adjustment 4 Turn adjusting screw by a few angular degrees abt 10 clockwise 0 8 Ampere 5 Unlock motor protection by the black key trouble signal goes out and the L filter pump is running Please see overleaf Uperating instructions PU 4UU ES
Download Pdf Manuals
Related Search
Related Contents
essential info for Half of Two guests K2 Dyno S Replay Controller Installation & Service Manual v 3.0 Man Al2000_eng - FF 622X 622M cross-connected SDH Optical Transmission System Design & Installation Manual Loxo® 50mm AAC Panel PortaBilling: User Manual GUÍA DEL USUARIO USER`S GUIDE Copyright © All rights reserved.