Operating Instructions Keypad 2605 .. -

image

Contents

1. Mode Indiv actuator Group actuator Relay Tones LED 1 YES NO NO 1 1 gang 2 YES YES NO 2 2 gang 3 YES NO YES 3 3 gang 4 YES YES YES 4 4 gang 3 If the key button is pressed again the keypad changes to the next mode 4 Repeat step 3 until the desired mode is reached 5 Press the Systemprogr button on the control device to exit the programming mode 39 Assigning mode to a user group To assign the corresponding mode to a user group proceed as follows 1 Press the Systemprogr button on the control device for 3 seconds to start programming mode y The LED at the control device flashes The keypad generates an acknowledgement tone and the LED flashes orange 2 The corresponding mode can be selected with admin PIN key button Admin PIN y With the first entering of the button combination the cur rent active mode is displayed with acknowledgement tones and flashing of the green LED Mode Indiv actuator Group actuator Relay Tones LED 1 YES NO NO 1 1 gang 2 YES YES NO 2 2 gang 3 YES NO YES 3 3 gang 4 YES YES YES 4 4 gang 3 If the key button is pressed again the keypad changes to the next mode 4 Repeat step 3 until the desired mode is reached 5 Press the Systemprogr button on the control device to exit the programming mode 40 Example 1 Starting up stand alone function In
2. 1 Start programming mode at the control device 2 Start door opener programming mode at the control device 3 Carry out the group assignment with the admin PIN 1212 1212 S 4 Exit programming mode at the control device Operation To switch on the light Press button F F he door can be opened with the following button combina tion 2345 49 Example 4 Integrating in door communication system without speech function If no speech function is required the keypad can be inte grated in the door communication system as follows 1 2 1 Keypad Bus coupler door communication 3 Switching actuator Control device 5 Door opener a i Pay attention before start up Before start up the bus coupler must be assigned to the control device For this a jumper is attached between the ET terminals for 3 seconds in system programming mode 50 Removal alarm The flush mounted insert generates an alarm signal after removal of the keypad With individual device f the keypad is removed from the flush mounted insert a 1 minute continuous tone is emitted In door communication system f the keypad is operated with the door communication sys em the removal signal can be forwarded to a switching actuator in addition to the 1 minute continuous tone Any
3. Button C deletes an incorrect 7 8 9 entry The complete button combination must then be re 0 C entered Button A triggering a door call In smaller buildings the button JAN can be used as a call button If the button A is pressed a door call is triggered at the assigned home station Button A calling a specific home station In buildings with several home stations assigned home sta tions can be specifically called For this purpose every home station receives its own user ID The home station is called via the following button combinations User ID UN Button open door The door is opened via the following button combinations In operating mode small buildings User PIN O In operating mode large buildings see Page 25 UserID UserPIN wz i Acknowledgement tones can be switched off Acknowledgement tones occurring during operation can be switched off see Page 23 Acknowledgement signals The keypad generates different acknowledgement signals during operation and start up Positive acknowledgement signal Vv The keypad generates a long acknowledgement tone the LED simultaneously lights up green Negative acknowledgement signal v The keypad generates 3 short acknowledgement tones the LED simultaneously lights up red Administrator mode activated v The LED lights up orange In door communication system Programming mode activated v Th
4. switching action can then be carried out via the switching actuator For this the switching actuator is assigned as follows 1 Press the Systemprogr button on the control device for 3 seconds to start programming mode vy The LED at the control device flashes The keypad generates an acknowledgement tone and the LED flashes orange The operating mode LED of the switching actuator flashes Press the button Progr at the switching actuator The keypad generates an acknowledgement tone again Remove the keypad from the flush mounted insert Press the Systemprogr button on the control device to exit the programming mode RON 51 Table for start up documentation Administrators Administrator Admin ID Admin PIN User User Function User ID User PIN 52 Procedure with loss of admin PIN If the set admin PIN s have been lost administrator mode can be started with use of the release code Freischaltcode in order to create a new administrator The release code is f d h Freischaltcode Toun onne 72 93 31 36 included security card GIRA Gira Keyless In Safety Card Codetastatur 1 Start administrator mode with the release code 0 Release code Vv After a positive acknowledgemen administrator mode signal the keypad is in 2 Create a new administrator see Page 18 53 Technic
5. also deleted Before reprogramming an administrator must be created 25 Difference between operating modes small building and large building The factory setting is preset to the operating mode small buildings Small building means e identical user PINs cannot be assigned e for door opening a user PIN only must be entered User PIN O Large building means e identical user PINs can be assigned e for door opening both a user ID and a user PIN must be entered UserID UserPIN i Information on start up IV_ In operating mode large building with the assignment of the key button to a switching actuator or door opener the user ID must additionally be entered UserID UserPIN 26 Integration in the door communication system Create administrator and user before start up Before before start up the keypad in the door communica tion system the corresponding administrators and users must be created from Page 15 Surface mounted home 2 station 2 Door station with keypad 3 Switching 1 actuator 4 Control device Door opener oa The keypad can be connected to the Gira flush mounted door stations and to the built in loudspeaker The keypad can con trol up to 16 switching actuators 8 group ac
6. device In this case the existing zero voltage relay contacts within the flush mounted insert are used e g for a door opener with own power supply Use as individual device not in safety relevant areas Not recommended for opening of outside doors especially in safety relevant areas as door may be opened with expan sion of keypad via bridging of open contacts Keypad Door opener 3 Power supply 24 V DC 4 Power supply of door opener N Use in door communication system The keypad can be connected to the door communication system via the enclosed connection cable Thus the keypad can control e g the door opener contact of the control device or can trigger the switching action of a switching actuator In addition further home stations can be specifically selected 1 Hands free feature 2 surface mounted home station 2 Flush mounted door station with 1 keypad 3 Audio control device 4 Door opener o 33088 g 1000 Protecting control device from unauthorised access In safety relevant areas the control device should be securely installed locked to prevent unauthorised access Operation Button F switching Pressing the button F controls 1 2 3 F the assigned switching actua tor 4 5 6 A Button C correction
7. ie e tee as 31 2 Assigning function button F to a switching actuator 32 Assigning bell button to a home station ceeeeeeeee 33 Specifically assigning bell button to a home station 34 Assigning bell button to a switching actuator 0 35 Specifically assigning bell button to a switching AGtUATOR ten tld Maser ete cb tnes trea E E NAE aes 36 Relays actuators what switches when 37 5 rules for selecting the correct mode 38 Assigning mode to an individual user 39 Assigning mode tO a user group ooo eeeeeeeecceeceeeeeeeeeeee seen ees 40 Examples Example 1 Start up stand alone function 00608 41 Example 2 Start up multi family house with door communication SYSTEM cecec eee eeeeeeceeeeeeeeeeeeeeeeeaes 43 Example 3 Start up single family house with door communication SYSTEM cece cceeeeeeeeeeeeee eee eeeeeeeeeees 47 Example 4 Integrating in door communication system without speech FUNCTION c cece ccc ceeee ee teeeeees 50 Removal alarmiccseussc0 fied aie cig thus etd ears O cid aiden 51 Table for start up documentation Procedure with loss of admin PIN Technical data secere raa web Warhanty cir AEE A E tales onde teas 55 Device description The keypad provides convenient and secure access control for inside and outside areas The keypad opens the door when a personal code is entered Capacitive switching t
8. this example relay 1 of the keypad switches the door opener 2 users should be able to open the door with their own PIN Switching 1 2 o o 2 2 2 3 4 1 Keypad 2 Door opener 3 Power supply 24 V DC 4 Power supply of door opener 41 Start up 2 users should be able to open the door The administrator has ID 1 and selects PIN 1212 User 1 has ID 2 and selects PIN 1234 User 2 has ID 3 and selects PIN 5678 1 Before first start up create an administrator ID 1 PIN 1212 3 1 1212 2 In administrator mode create persons 1 and 2 for the door opener function relay 1 User 1 ID 2 PIN 1234 ed 2 k 1234 User 2 ID 3 PIN 5678 song 3 5678 Operation To open the door the following combinations must be entered User 1 1234 O User 2 5678 10 42 Example 2 Starting up multi family house with door communication system In this example 3 home stations in a multi family house should be specifically called via the keypad Switching 1 2 2 1 2 2 alp 2 2 K 1 eo slo 2 es 2 l 4 1 Surface mounted home 2 2 station 2 Door station 3 Control device 3 4 Door opener 43 Start up The administrator has ID
9. with ID and PIN into the table on Page 52 Changing admin user PIN The corresponding PIN is changed when the user or admin istrator is assigned a new PIN 1 Start administrator mode if not already active 0 Admin PIN Vv After a positive acknowledgement signal the keypad is in administrator mode y A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN 2 Change user PIN 4 UserID User PIN Change admin PIN 4 Admin ID Admin PINy v The keypad generates a positive acknowledgement signal The PIN has been successfully set v The keypad generates a negative acknowledgement sig nal Invalid ID entered 3 Administrator mode ends after 15 seconds automatically or after entering 0 IV Deleting user A user is deleted as follows 1 Start administrator mode if not already active 0 Admin PIN Vv After a positive acknowledgement signal the keypad is in administrator mode y A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN 2 Delete user 5 UserID Vv The keypad generates a positive acknowledgement signal The user was deleted successfully Vv The keypad generates a negative acknowledgement signal An incorrect user ID was entered y Further users can now be deleted 3 Administrator mode ends after 15 seconds a
10. 1 and selects PIN 1212 A user is created for each home station for the upper flat ID 11 with PIN 1234 for the middle flat ID 22 with PIN 2345 for the lower flat ID 33 with PIN 3434 1 Before the first start up create an administrator ID 1 PIN 1212 on 1 bd 1212 2 Create the users for the home stations in administrator mode They are created for relay 1 Upper flat ID 11 PIN 1234 wheel Nias 11 i 1234 Middle flat ID 22 PIN 2345 AATE 22 hi 2345 Lower flat ID 33 PIN 3434 Hes 33 3434 44 Assigning the flats 1 Start programming mode at the control device 2 For the upper flat 11 A For the middle flat 22 A For the lower flat 33 A 3 Press the Light button at the upper home station Press the Light button at the middle home station Press the Light button at the lower home station 4 Exit programming mode at the control device 45 Assigning the door opener All users should be able to open the door after entering their own PIN The door opener control of the control device is thus assigned as group actuator 1 Start programming mode at the control device 2 Start door opener programming mode at the control device 3 Carry out the group assignment with the admin PIN 1212 1212 o 4 Exit programming mode at the control device Operation For calling a home station select Us
11. D next to the button flashes v The keypad generates an acknowledgement tone again 3 User ID press Bell button User ID Li v The keypad generates a positive acknowledgement signal The switching actuator was assigned successfully 4 Press the Systemprogr button on the control device to exit the programming mode Delete assignment of Bell button switching actuator To delete the Bell button switching actuator assign ment take note of information on Page 35 36 Relays actuators what switches when The following rules apply with the basic configuration of the switching actuators assignments e The relays of the keypad are not switched as soon as a switching actuator is assigned e An individual switching actuator always has a higher prior ity than a group switching actuator Individual actuator Group actuator Relay not assigned not assigned switches not assigned assigned switches does not switch assigned switches assigned does not switch does not switch Extended configura tion In the basic configuration a user switches only the assigned switching actuator this user additionally triggers the group actuator or a relay of the keypad the user is assigned a special mode Assigned A Mode individual hase ioh Assigned relay 1 switches does not switch does not switch 2 switch
12. Operating Instructions Keypad 2608 IRA Contents Device description nie eee cece ccc ce cece eeeeeeeeeseneeeeeeteeeaneeeeeee 4 Device Presentation ccccceceeeeceeeeeeeaeeeeeeeeeeeaneeeees 5 Areas Ol AP PlICAtIO Me aresep a Siccacteseutud oh Ate etd cients aes 6 PETAL OM es ote ae SRS AS R N ese Sense nent 8 Acknowledgement Signals ccccccsceeeceeeeeeeeeeeeeeeeeeen ees 0 Start Up SEQUENCE ie mie eiaeia in sean tias iotah tiat 1 Connection terminals eostet ae a S 2 installation tenni S EEEE R EN 3 What is an administrator a USE ssccecceccereirerrereereei 4 Creating first administrator 15 Creating user for relay 1 16 Creating user for relay 2 Pie Create a further administrator eee eeeeeeeeeeeeeeeees 8 Changing admin user PIN 0 cececeeeeeeeeeeeeeeeeeeeeeeeeeeees 9 Deleting USER a eaaa Enora RE ESE M caetdandaseeteiaasa EF 20 Deleting AdMiInistrator seseris ir E 21 Switching button illumination on off ceeeeeeeees 22 Switching acknowledgement tones on off 06068 23 Setting switching time of relays cece eec cece ee eeeeeees 24 Resetting to factory settings selection of operating mode 25 eypad in door communication SySteM cccceeeeeeeee Connection to door communication system Assignment of user specific switching actuator COOr Opener EETA EE EE E E 30 Assignment of user group switching actuator dOOrOpEnET siyete a
13. ad are assigned a group switching actuator or group door opener 1 Press the Systemprogr button on the control device for 3 seconds to start programming mode vV The LED at the control device flashes The keypad generates an acknowledgement tone and the LED flashes orange The operating mode LED of the switching actuator flashes 2 Press the button Progr at the switching actuator or the button Turdffnerprogr of the control device until the LED next to the button flashes v The keypad generates an acknowledgement tone again 3 Enter admin PIN and press key Admin PIN v The keypad generates a positive acknowledgement signal The switching actuator was assigned successfully 4 Press the Systemprogr button on the control device to exit the programming mode V i Delete assignment of user switching actuator To delete the user switching actuator assignment the teach in procedure is repeated 31 Assigning function button F to a switching actuator 1 Press the Systemprogr button on the control device for 3 seconds to start programming mode y The LED at the control device flashes The keypad generates an acknowledgement tone and the LED flashes orange The operating mode LED of the switching actuator flashes 2 Press the Progr button on the switching actuator until the LED next to the button flashes v The keypad generates an acknowledgement tone again 3 Press function b
14. al data Power supply 24 V DC 10 or via the Turko BUS Protection type IP 20 system 55 IP 44 TX_44 Temperature range 20 C to 70 C Resistance to EMD up to 16 kV Relay load capacity 24 V 1 6 A AC DC i Relay protection with free wheeling diode For protection of relay contacts it is recommended to paral lel connect a free wheeling diode when connecting induc tive loads e g door openers 54 Warranty We provide a warranty in accordance with the statutory requirements Please send the device postage paid with an error descrip tion to our central customer service centre Gira Giersiepen GmbH amp Co KG Service Center Dahlienstra amp e 12 D 42477 Radevormwald 55 Gira Giersiepen GmbH amp Co KG Electrical Installation Systems Postfach 1220 D 42461 Radevormwald Germany Tel 49 0 2195 602 0 Fax 49 0 2195 602 339 www gira de info gira de 21 07 GIRA
15. at a later date in the keypad can switch this common switching actuator without further programming i Additional acknowledgement tone If the switching actuator is assigned in the operating mode switching the door station connected to the keypad gen erates an additional acknowledgement tone V 29 Assignment of user specific switching actuator door opener Users must be created in the keypad beforehand from Page 16 1 v Press the Systemprogr button on the control device for 3 seconds to start programming mode The LED at the control device flashes The keypad generates an acknowledgement tone and the LED flashes orange The operating mode LED of the switching actuator flashes Press the button Progr at the switching actuator or the button Turdffnerprogr of the control device until the LED next to the button flashes The keypad generates an acknowledgement tone again Enter user PIN and press key User PIN The keypad generates a positive acknowledgement signal The switching actuator was assigned successfully Press the Systemprogr button on the control device to exit the programming mode V i Delete assignment of user switching actuator To delete the user switching actuator assignment the teach in procedure is repeated 30 Assignment of user group switching actuator group door opener The following describes how all users stored in the keyp
16. buildings on p 26 Creating first administrator Before first start up an administrator must be created If no administrator has been created the LED of the keypad flashes green i Admin ID and admin PIN Admin ID and admin PIN cannot be used for switching actions e g for opening of a door Create administrator y LED flashes green lI 1 Create new administrator 3 Admin IDy Admin PINy vy The keypad generates a positive acknowledgement sig nal An administrator was created successfully The keypad is now in administrator mode 2 Enter administrator with ID and PIN into the table on Page 52 i Correct operating mode selected Upon delivery the operating mode small buildings is pre set This means that identical PINs cannot be assigned Fur ther information about operating modes small buildings large buildings on Page 26 Creating user for relay 1 The following describes how a user is created for relay 1 1 v Il 3 Start administrator mode if not already active 0 Admin PIN After a positive acknowledgement signal the keypad is in administrator mode A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN Create user for relay 1 1 UserID User PIN ey The keypad generates a positive acknowledgement sig nal The user was created successfully Further users can now be create
17. d Administrator mode ends after 15 seconds automatically or after entering Ons Enter user with ID and PIN into the table on Page 52 Creating user for relay 2 The following describes how a user is created for relay 2 1 v Start administrator mode if not already active 0 Admin PIN After a positive acknowledgement signal the keypad is in administrator mode A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN Create user for relay 2 2 User IDy User RINI The keypad generates a positive acknowledgement sig nal The user was created successfully Further users can now be created Administrator mode ends after 15 seconds automatically IH or after entering On Enter user with ID and PIN into the table on Page 52 Create a further administrator An 1 v 4 administrator is created as follows Start administrator mode if not already active 0 Admin PIN After a positive acknowledgement signal the keypad is in administrator mode A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN Create new administrator 3 Admin IDy Admin PINy The keypad generates a positive acknowledgement signal The administrator was created successfully Administrator mode ends after 15 seconds automatically or after entering 0 Enter administrator
18. e keypad generates a short acknowledgement signal the LED flashes orange Programming mode terminated v The keypad generates a short acknowledgement tone the LED is off i Acknowledgement signal off If the acknowledgement tone is switched off see Page 23 there are no more acknowledgement tones The acknowl edgement signals then occur solely via the LED Start up sequence For start up the keypad the following steps must be imple mented in the order shown below Install keypad from Page 12 LED flashes green ll Create first administrator Page 15 3 Admin IDy Admin PINy Ill Create user for relays 1 2 from Page 16 1 2 User IDy User PIN ewy IV Carry out configurations to keypad from Page 19 V Use in door communication system Assigning door opener switching actuators from V p 27 Connection terminals Relay 1 N O NO contact Relay 1 Relay 1 COM Relay 1 N C NC contact not used Service not used GND Relay 2 N O NO contact CO N OI a A Ww mM Relay 2 Relay 2 COM o Relay 2 N C NC contact GND Power supply 24V DC N not used 6 pole slot door communication system wo Door communication 12 Installation A Attention Installation and mounting of electrical devices may only be carried out by a qualified
19. ech nology enables operation by a light touch of the finger The keypad can be used as a stand alone function e g at individ ual doors or gates It can also be integrated into the Gira door communication system No additional control components are required here Easy start up without a PC or programming software is pos sible via direct configuration at the device The two integrated zero voltage two way switch relays can be assigned to different codes Thus it is possible to carry out two different switching processes e g code 1 for door open ing and code 2 for switching the outside light via a remote control switch The keypad can manage up to 255 codes incl admin code and release code The keypad is installed indoors IP 20 in conjunction with System 55 cover frames and outdoors IP 44 with TX_44 cover frames Device presentation TX_44 1 Connection cable for door communication system 2 Flush mounted insert keypad 3 TX_44 cover frame bottom section not included in scope of supply 4 Keypad Status LED 6 TX_44 cover frame top section not in scope of supply oa System 55 1 Connection cable for door communication system 2 Flush mounted insert keypad 4 3 System 55 cover frame not in scope of supply 45 6 O 5 4 Keypad 7 8 9 5 Status LED s 0 GR SC Areas of application Use as individual
20. electrician l The keypad is connected via both detachable terminal strips and mounted in a 58 mm flush mounted box 1 Pull off required terminal strip and connect according to terminal figuration Attach terminal strip to the flush mounted insert again Install flush mounted insert into flush mounted box Install cover frame and attach cover plate of the keypad 10 seconds after operating voltage is applied the LED of the keypad flashes green 5 Start up the keypad e first create an administrator Page 15 e then create the user from Page 16 e then if necessary assign switching actuator functions or door opener functions from Page 30 VR ON What is an administrator a user For starting up an administrator must be created Users are created for operation Administrator An administrator always consists of an admin ID and an admin PIN e Admin ID 1 to 6 digit e Admin PIN 1 to 32 digit for configuration of keypad User A user consists of a user ID and a user PIN e User ID 1 to 6 digit for door call functions e User PIN 1 to 32 digit for door opening functions or switching actions i Information about IDs and PINs The allocation of identical IDs is not possible If an adminis trator receives ID 1 there cannot be a user with the ID 1 The allocation of identical PINs is only possible in operating mode large buildings Further information about operating modes small buildings large
21. en be assigned 33 V Specifically assigning a bell button to a home station i Create user To specifically assign a bell button to a home station a user must be created in the keypad for this home station Page 16 1 Press the Systemprogr button on the control device for 3 seconds to start programming mode y The LED at the control device flashes The keypad generates an acknowledgement tone and the LED flashes orange 2 User ID press Bell button User ID AN v_ The keypad lights up orange the door station generates a short and a long acknowl edgement tone the keypad flashes orange 3 Press the button Light on the home station for 3 seconds until a short acknowledgement tone is heard Along acknowledgement tone confirms successful assignment Vv Three short acknowledgement tones indicate faulty assignment The memory of the home station may already be occupied 4 Press the Systemprogr button on the control device to exit the programming mode 34 Assigning bell button to a switching actuator With parallel assignment of the bell button to a switching actuator and a home station first assign the switching actu ator then assign the home station 1 Press the Systemprogr button on the control device for 3 seconds to start programming mode y The LED at the control device flashes The keypad generates an acknowledgement tone and the LED flashes orange The ope
22. er ID LY e g for the middle flat 22 A The door can be opened with the following button combina tion User PIN O Occupants of the middle flat open the door with 2345 D 46 Example 3 Starting up single family house with door communication system In the single family house all occupants should be able to open the door The outdoor lighting should be switched on via the button E Switching 2 2 1 Surface mounted 2 home station 2 2 Door station Switching actuator 3 4 C N5 Control device Door opener AUN 47 Start up The administrator has ID 1 and selects PIN 1212 A user is created with ID 2 and PIN 2345 Before the first startu up create an administrator ID 1 PIN 1212 mares 1 i 1212 In administrator mode create the user for the home sta ID 2 PIN 2345 It is created for relay 1 fe Hee 2 2345 Assigning the switching actuator 1 Start programming mode at the control device ion 2 Start the programming mode at the switching actuator and select the operating mode Timer min 3 Press the function button F on the keypad F 4 Exit programming mode at the control device 48 Assigning the door opener Users of the house should be able to open the door after entering their PIN
23. es switches does not switch 3 switches does not switch switches 4 switches switches switches Factory setting 37 5 rules for selecting the correct mode Ru ft Ru 1a Ru fa ind 38 e1 he door communication system has not been assigned any switching actuators the relays assigned to the user are always switched e2 f the relays should switch together with a switching actuator individual group mode 3 or 4 must be selected Rule 3 An individual switching actuator assigned to an individual user always has a higher priority than a group switching actuator Rule 4 f a group switching actuator is assigned it switches in mode s long as no individual switching actuator is assigned e5 group switching actuator should switch together with an ividual switching actuator mode 2 or 4 must be selected Assigning mode to an individual user To assign the corresponding mode to a user proceed as fol lows 1 Press the Systemprogr button on the control device for 3 seconds to start programming mode v The LED at the device unit flashes The keypad generates an acknowledgement tone and the LED flashes orange 2 The corresponding mode can be selected with user PIN key button User PIN O y With the first entering of the button combination the cur rent active mode is displayed with acknowledgement tones and flashing of the green LED
24. ode A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN Start procedure 63 The LED lights up red Press a button to start switching time The keypad generates an acknowledgement tone every second the LED simultaneously flashes green The relays are not activated during setting of the switch ing time To end setting of the switching time press any button again The keypad generates a positive acknowledgement sig nal The switching time was successfully set Administrator mode ends after 15 seconds automatically or after entering 0 Resetting to factory settings selection of operating mode The keypad can be reset to the state of delivery In this case all user and administrator assignments are lost 1 Start administrator mode if not already active 0 Admin PIN Vv After a positive acknowledgement signal the keypad is in administrator mode A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN 2 Factory setting operating mode small buildings 9 1230 Factory setting operating mode large buildings OTANI v The keypad generates a positive acknowledgement sig nal then flashes green red The LED then flashes green all keypad settings have been reset all users and administrators deleted The keypad is in the selected operating mode Important Administrator
25. rating mode LED of the switching actuator flashes 2 Press the Progr button on the switching actuator until the LED next to the button flashes v The keypad generates an acknowledgement tone again 3 Press Bell button I vy The keypad generates a positive acknowledgement signal The switching actuator was assigned successfully 4 Press the Systemprogr button on the control device to exit the programming mode Delete assignment of Bell button switching actuator To delete the Bell button switching actuator assign ment the Progr button of the switching actuator is pressed for 6 seconds in the active programming mode of the door communication system In this case all assign ments of this switching actuator are deleted 35 Specifically assigning the bell button to a switching actuator To specifically assign the bell button to a switching actuator a user must be created in the keypad for this switching actu ator With parallel assignment of switching actuator and home station first assign the switching actuator then assign the home station 1 Press the Systemprogr button on the control device for 3 seconds to start programming mode y The LED at the control device flashes The keypad generates an acknowledgement tone and the LED flashes orange The operating mode LED of the switching actuator flashes 2 Press the Progr button on the switching actuator until the LE
26. tion ee Old fala Switch off illumination Gil Old v The keypad generates a positive acknowledgement signal The illumination was switched on off successfully 3 Administrator mode ends after 15 seconds automatically or after entering 0 22 Switching acknowledegment tones on off The acknowledgement tones are activated deactivated as follows In addition quiet or loud acknowledgement tones can be selected 1 Start administrator mode if not already active 0 Admin PIN Vv After a positive acknowledgement signal the keypad is in administrator mode VY A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN 2 Switch off acknowledgement tones 62 O Switch on acknowledgement tones quiet SG Zul H Switch on acknowledgement tones loud 162 2 v The keypad generates a positive acknowledgement signal IV The acknowledgement tones were successfully set 3 Administrator mode ends after 15 seconds automatically or after entering 0 23 Setting switching time of relays Switching time of the relays can be set from 3 to 30 seconds The set contact hold time is valid for both relays de v oo 24 Start administrator mode if not already active 0 Admin PIN After a positive acknowledgement signal the keypad is in administrator m
27. tuators 8 indi vidual switching actuators and the door opener function In addition home stations can be called directly from the door communication system Full functionality of the switching actuators from index 104 27 Connection to door communication system The keypad is connected to a door communication bus cou pler or call button insert of the Gira door communication sys tem with the accompanying connection cable 7 89101112 000000 1 Keypad BUS 2 Door communication bus coupler Power supply for the keypad is possible via the door commu nication bus In this case jumpers between ZV and BUS must be attached to the bus coupler of the door station Firstly start up door communication system Before programming of the keypad is begun the door communication system must be started up 28 Direct assignment group assignment Assignment differentiates between e direct assignment of individual users to an individual switching actuator e group assignment of all users to a switching actuator With group assignments all users assigned to the keypad trigger a switching action with the switching actuator During programming the admin PIN is entered instead of a user PIN i Advantage of group assignment With group assignments all users in a programming step are assigned a common switching actuator Users that are created
28. utomatically or after entering 0 4 Remove deleted users from the table on Page 52 20 Deleting administrator An administrator is deleted as follows 1 Start administrator mode if not already active 0 Admin PIN Vv After a positive acknowledgement signal the keypad is in administrator mode A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN 2 Delete administrator 5 AdminID v The keypad generates a positive acknowledgement sig nal The administrator was deleted successfully Vv The keypad generates a negative acknowledgement sig nal An incorrect admin ID was entered ZY Further administrators can now be deleted 3 Administrator mode ends af or after entering i Last admin cannot be deleted 0 er 15 seconds automatically The last remaining administrator can only be deleted via resetting to factory settings Page 25 4 Remove deleted administrators from the table on Page 52 21 Switching button illumination on off The illumination of the keypad can be switched as follows 1 Start administrator mode if not already active 0 Admin PIN Vv After a positive acknowledgement signal the keypad is in administrator mode V A negative acknowledgement signal indicates an incor rect entry e g of the admin PIN 2 Switch on illumina
29. utton F F Vv The keypad generates a positive acknowledgement signal The switching actuator was assigned successfully 4 Press the Systemprogr button on the control device to exit the programming mode Delete assignment of button F switching ac tuator To delete the button F switching actuator assignment the teach in procedure is repeated 32 Assigning bell button to a home station 1 v N Press the Systemprogr button on the control device for 3 seconds to start programming mode The LED at the control device flashes LED flashes orange Press Bell button A short and a long acknowledgement tone the keypad flashes orange Press the button Light on the home station for The keypad generates an acknowledgement tone and the The keypad lights up orange the door station generates a 3 seconds until a short acknowledgement tone is heard A long acknowledgement tone confirms successful assignment Three short acknowledgement tones indicate faulty assignment The memory of the home station may already be occupied Press the Systemprogr button on the control device to exit the programming mode i Assign several home stations per work step Up to 20 code assignments can be temporarily stored per step If more than 20 home stations are to be assigned the first 20 codes must first be entered and then assigned to the home stations The remaining codes can th

Download Pdf Manuals

image

Related Search

Related Contents

LANパススルーブレード(PG-LNB101)取扱説明書 GbE Pass  Manual Descargar - Hitachi  Alpine MRD-M1000 Stereo Amplifier User Manual  Control de salas de calderas  Cisco Systems 1520 Network Router User Manual  Când.. italienii emigrau în România…  NEC  Delius 取扱説明書.indd  los proyectos hacen los objetos eternos, las modas los  