Home

GEIGER-Funk Blind Controller GFJ006 GFJ007 GFJ009 Installation

image

Contents

1. Antriebstechnik GEIGER Funk Sunshade controls Blind Controller for 230V drives GFJ006 GFJ007 GFJ009 Installation and Operating Instructions a oe SEES or Sy Table of Contents 1 Introduelion ni need nid eher hen ern T 3 2 Safety Instructi ns naiaiae cette RR Mee EE E Irre iR 3 3 Intended Usage iii sheet apices scat nr eee a cent tin 3 4 Connection and installation 0 cece cere eee nee A OEE ERE EEA REE EA 4 4 1 Installatisninstructions 242 2 2 2 arena ae era 4 4 2 Circuit diagram GFJ006 arrer eetan ieena inita daana aa Neea aae ENAA A EEE EAA 4 4 3 Pl g in version GFJ007 eeina E OARE EE ea et 4 4 4 Plug in version GFJ009 as control GFJO09 ssssseesesseeereseerrreserrreseetrrsssttrnnssttnnsstenrnsstennns 4 S U PO seats cae A EE A E TE EE EA E E A A A A tie ae 4 Extensions and individual settings siriniiniei irene ia EA E NEEE ATERA SEAT EEA EARRAS 5 6 1 Teaching in radio commandS 44rsnnesnnennnnnnnennnnnnnnennnnnnnnnnnnnnnnennnnnnnnnnnennnnnnnnn danant 5 6 1 1 Activate delete learning mode a sssssssssissssrrnesesrnnesnrnrnssinnnnsannnnneninennnatnnanennnannananna 5 6 1 2 Learning of radio CodeS ia a a E A A ARE 6 6 1 3 Learning the assignment of the controlkeys sessssseessseeerreseeerrsssrirrsssrtrrrssrrrnnssene 7 6 14 Learning of running times ainra t a EE EE EE 8 T Functions of thecontrolor o enserre iieii ii eaa Rein 9 7 1 Operat
2. Distance range distance between hand transmitter and device min 1 5 m Learning mode is activated Via short signal tones the controller request you to begin with the learning procedure i Actuate key UP 1 sec Many short tones closely Radio code is already with the hand transmitter gt following each other m learned at close range i 1 long tone is emitted for acknowledgement l Setting of radio code is completed 6 1 3 Learning the assignment of the control keys Close range hold the hand transmitter close to the antenna Distance range distance between hand transmitter and device min 1 5 m The assignment of the control keys must be effected before the learning of the running times Learning mode is activated Via short signal tones the controller request you to begin with the learning procedure l Actuate key UP 1 sec with the hand transmitter at distance range i 1 long signal tone ere Actuate key UP 1 sec with the hand transmitter at close range Y 1 long signal tone eg The assignment of the UP and DOWN keys is changed The learning procedure is completed 6 1 4 Learning of running times Close range hold the hand transmitter close to the antenna Distance range distance between hand transmitter and device min 1 5 m The assignment of th
3. FJ009 requires a supply voltage of 230V 50Hz for operation Please note that only a skilled electrician as defined by VDE0100 may install the controller e The controller is only to be used for its intended purpose as described under Section 3 of the operating instructions Changes or modifications to the controller void any rights to claims under the guarantee e After unpacking the controller check it right away for any damage If it is damaged the unit may absolutely not be put into operation Shipping damage is to be reported to the supplier immediately When it can be presumed that the controller does not operate faultlessly it is to be immediately taken out of service and secured against inadvertent use This can be assumed if the housing or the mains motor cables are damaged or if the unit is no longer working e According to VDE 0022 the owner himself is responsible for compliance with EVU or VDE regulations as well as for proper installation e The supply voltage must first be switched off when working on the blind controlled by the GFJ006 GFJ007 GFJ009 3 Intended Usage The blind controllers GFJ006 GFJ007 and GFJ009 may only be used for controlling 230V 50Hz 1 phase blind motors The blind controllers GFJ006 GFJ007 GFJ009 all IP54 must be installed in the blind box so that they are protected against splash water When cleaning the Venetian blinds please make sure that you do not splash or direct water on
4. e control keys must be effected before the learning of the running times also see Nr 6 1 3 Learning the assignment of the control keys Learning mode is activated Via short signal tones the controller request you to begin with the learning procedure Actuate key UP 1 sec Press key DOWN till with the hand transmitter Venetian blind moves at distance range downwards and run the blind to the lower limit osition y p 1 long signal tone Wait for approximately Y 2 seconds Press key UP till run time reserve Venetian blind moves upwards and run the blind to the upper limit position Actuate key UP 1 sec with the hand transmitter at distance range Actuate key DOWN i Actuate UP and DOWN 1 sec with the hand trans key with the hand mitter at distance range The running time transmitter at distance for the lower limit stop range to set the slat is learned adjustment angle The running time for the upper limit stop is learned Actuate key Actuate key UP 1 sec DOWN 1 x at with the hand transmitter distance range at close range 1 long signal tone The learning of the running time is completed 7 Functions of the controller 7 1 Operation by transmitter with two keys with interlock Stop The two control keys OPEN CLOSED are assigned to the blind s retract extend travel directions The sto
5. e sequence 1 long tone 1 long tone Many short tones closely following each other 6 tones 1 very long tone 1 long tone 1 long tone Controller signals S O S Short tones at intervals of approx 500 ms 6 tones Report Switch on message after switching on the mains voltage Learning mode activated Radio codes for both running directions have been learned Error message The radio code to be learned has already been issued Error message Learning interrupted because the time has expired The radio codes have been deleted Switchover has occurred to the next memory area The assignment of the relays to the Open and Closed directions has been mixed up Error message Saving not possible as memory module is defective Controller must be repaired Error message Data in the memory module has been lost Teach the controller again If the error occurs again the controller must be repaired Error message Sensors not supported 9 Technical characteristics Supply voltage Active power consumption of the controller Relay switching currents resistive Protection type Motor runtime Slat adjustment angle 230V AC 10 50 Hz approx 0 4 W 5A IP54 0 270 sec can be taught 90 sec fixed value 0 2 5 sec can be set in 0 1 sec steps Operating delay time after wind and rain command 10 minutes Operating delay time after Service command 5 minutes Sun extension command Sizes o
6. f housing Length of connecting cables only GFJ006 after 3 minutes length 90 mm width 30 mm depth 19 mm Power connection 1500 mm Motor connection 200 mm 10 Declaration of Conformity We herewith explicitly declare that this product complies with the essential requirements and relevant directives It is authorised for use in all EC member states and in Switzerland without any need of prior registration The Declaration of Conformity concerning this product is available on our website www geiger antriebstechnik de 11 Notes on waste disposal Recycling of packaging materials In the interest of environmental protection please contact your local government s recycling or solid waste management department to learn more about the services it provides Waste disposal of electric and electronic equipment Electronic equipment or batteries cannot be discarded along with the normal household waste Keep for more information on the recycling and disposal methods envisaged by the local regulations in your area 11 Gerhard Geiger GmbH amp Co KG Schleifm hle 6 e D 74321 Bietigheim Bissingen Phone 49 0 7142 9 38 0 Fax 49 0 71 42 9 38 230 info geiger antriebstechnik de e www geiger antriebstechnik de 12 DB 099 00 00 00 100W0616 en 0811
7. ion by transmitter with two keys with interlock Stop ssssesessssesrirsseserrsseerrrsseeernesees 9 7 2 Operation by radio Sensors oeeoiieaci eikeen innesi ANE aa Rennir AEN PAA iN ANEA 9 7 3 Block enable automatic sun function uuerssssesnnsnnnnnnnennnnnnnnennnnnnnnnnnnnnnnnnennnnnnnnnnnn nn 9 8 Signal tones of the controller and error diagnosis uursnsennnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nenn 10 9 Technical characteristics iiese sedis nen a een 10 10 Declaration or Contool yorini aa rn 11 11 Notes on waste disposal 44444040ennennnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnsnnannnnnnnnnnennnnnnsnnnnnnnnnnn en 11 1 Introduction Purchasing the blind controller GFJO06 GFJ007 GFJ009 was a good decision You have acquired a high quality product from the house of Geiger This blind controller is operated only via radio commands The following operating methods are possible e Manual operation with manual radio transmitters and wall mounted radio transmitters e Automatic program with sensors for sun and wind e Time controlled functions via radio time switch e Higher order service functions e g for window cleaning The following radio command assignments are possible and apply to all operating modes e Individual control e Group control any number of in range receivers e Central control any number of in range receivers 2 Safety Instructions e The blind controller GFJO06 GFJ007 G
8. p command is issued with the corresponding interlock key for the triggering command key 7 2 Operation by radio sensors The controller can learn the radio coding of two different sensors If a sensor coding has been learned see instruction Automatic Radio Controller GF0024 the controller reacts to the commands Sun Twilight and Wind from sensors that have this coding e If Wind is received a retract command is triggered and a delay time is started for each Operation is no longer possible during the delay time The sunlight and twilight sensors are blocked 7 3 Block enable automatic sun function Attention Manual operation of the controller has precedence over sun automatic operation Every manual operating command of the controller interrupts automatic mode with sun and twilight sensors The automatic sun function is active again when the blind is fully retracted again the taught motor run time or the fixed run time of 90 seconds must have expired e Ifa manual transmitter GF0004 with the special functions Block enable automatic sun function was taught into a memory location for sensors the automatic sun function can be blocked and enabled again irrespective of the previous operation These special commands have no cancelling effect on the initiated delay times Attention After the mains voltage is switched on the sensors are initially enabled 8 Signal tones of the controller and error diagnosis Tone sequence Ton
9. the motor control 4 Connection and installation 4 1 Installation instructions The distance between two blind controllers GFJ006 GFJ007 GFJ09 should be at least 0 5 meters The clearance from a permanently installed transmitter e g sun wind automatic SW3 should be at least 2 meters 4 2 Circuit diagram GFJ006 SEA id UP black Mi DOWN brown 5 SEZ N blus _ FE green yellow a u ins The rotation direction can be changed a L1 brown depending on the mounting situation was N blue There are 2 possibilities 230W fu i 1 exchange black and brown connection PE green yelkow ZDSS Connecting cables with plug connectors of the Hirsch 2 rae gt H coordination per mann Company type STAS 3K or the Phoenix Mecano Bi Company type GLS 3 PE may only be used in connection with the Hirschmann cable socket STAK 3K 4 3 Plug in version GFJ007 F 1 S Connection ee For simple installation the blind ana plug controller GFJ007 comes already 1 ei supplied with a Hirschmann plug Fan 1 N blue STAS3 for mains connection 2 L1 brown black and a GEIGER coupling M56K a 3 NC not reserved for connecting the motor wa 4 PE green yellow 4 4 Plug in version as control GFJ009 For simple installation the blind controller GFJO09 comes already supplied with a Hirschmann plug STAS3 for mains connection and STAK3 for connecting the motor 5 Set up e Adjust the blind s limit switches according to manufac
10. turer s instructions e Connect the blind controller GFJ006 according to the circuit diagram or connect the blind controller GFJ007 with the coupling STAK3 see circuit diagram and establish connection plug STAS3 for mains connection coupling M56K for motor connection or connect blind controller GFJ009 with STAK3 and STAS3 e Ready The pre coded system can now be operated by radio Convenience settings such as run time learning with the slat adjustment angle can also be made at leisure later For details read Point 6 1 3 6 Extensions and individual settings 6 1 Teaching in radio commands The controller has a total of 8 memory locations for radio codings of which 3 x 2 memory locations are intended for manual transmitters and 2 are intended for sensors Manual transmitters always have 2 keys that work by mutually interlocking and that each occupy 2 memory locations Sensors each occupy only one memory location 6 1 1 Activate delete learning mode 1 Setthe individual coding on the manual transmitter via the DIP switch see instruction manual transmitter The receiver makes the difference between proximity close range and distance distance range When learning the device we therefore send the inputs either at close range or at distance range Close range hold the hand transmitter close to the antenna Distance range distance between hand transmitter and device min 1 5 m Normal operating mode Y S
11. witch the power supply briefly 2 sec off and then back on Y Tone sequence Y gt Normal operating mode the learning mode can be activated T gt 30 minutes Learning mode activation is locked Actuate any of the 2 keys 3 sec with the hand transmitter at close range 1 long signal tone Y Learning mode is activated Via short signal tones the controller request you to begin with the learning procedure Y Y Y Y Learning Learning Learning Actuate any of radio of running a sensor of the keys codes time see UP and DOWN see see separate 8 sec separate separate instructions with the hand instructions instructions transmitter at No entries see 6 1 2 see 6 1 3 see 6 1 4 close range for T gt 30 sec Y All radio codes are deleted Y signal tone 6 signal tones 1 very long Y Y Y Y Learning mode is completed 6 1 2 Learning of radio codes The device is delivered pre coded with Geiger coding For the first learning of a radio code the Geiger code will be replaced by a transmitter code Three different radio codes can be learned If three radio codes have already been learned and if an attempt is made to learn a 4th one the last code actually stored is deleted and the new code stored instead Close range hold the hand transmitter close to the antenna