Home
Operating Instructions for Electronic Lock E6000 with Opening Delay
Contents
1. SECU GmbH Wormgermthle D 58540 Meinerzhagen Tel 02358 905280 PCU Sicherheitsorodukte GmbH NUMBER LOCK WITH 111 MILLION GENUINE SETTING CONFIGURATIONS Operating Instructions for Electronic Lock E6000 with Opening Delay and Mastercode Electronic lock E6000 listed as UL type and approved in VdS class 3 with a mastercode serves as an electronic central locking station allowing up to 9 sub levels standard numerical codes of 6 to 8 figures to be selected modified or canceled from the main level the 9 figure mastercode The E6000 can be programmed from outside to either set the lock for immediate access after entering the correct numerical code or for delayed access after a pre set waiting period KEYING IN THE NUMERICAL CODE In this instruction you are requested to key in a numerical code several times Please turn the dial until you see the first digid at the illuminated display Press ENTER key Turn the dial again until you see the second digid Press ENTER key After the last digid turn the dial until you see the sign gt and continue with the following instructions OPENING THE SAFE OR STRONGROOM Press EIN ON key After a short high pitched signal tone either key in the 9 figure mastercode or one of the the 6 to 8 figure standard codes factory setting of only the mastercode 123456789 gt Press ENTER key you will hear the short high pitched signal tone again A short low pitched signal tone indicates
2. that you entered the wrong code If the opening delay is set to 0 zero minutes factory setting please proceed with step 6 Wait for the set opening delay to lapse During the waiting time the safe cannot be opened The end of the opening delay is indicated by short high pitched signal tones lasting 30 seconds Press ENTER key before the sounding of the signal tones ceases and re enter the valid numerical code Complete by pressing the ENTER key Open the lock by the lock handle by turning it a half turn The electronics will switch itself off automatically after 5 seconds Now open the door by turning the door handle SECURING THE SAFE OR STRONGROOM If it should only be possible to open the safe or strongroom by entering the numerical code the door and lock handles have to be turned back in their original position first lock the door then the lock LOCKING THE SAFE OR STRONGROOM The safe or strongroom is locked by turning the door handle It can then be opened without re entering of the numerical code page Subject to technical modifications 6000 Generalcode Betriebsanleitung englisch p65 Date 02 01 REMARKS After keying in a wrong number the number combination can be deleted by pressing the EIN ON key After that the opening procedure can be repeated After keying in the wrong number combination three times in a row the electronic system blocks the safe for five minutes Following that the electronic
3. completed correctly Low pitched tones 1 x short 2 x short 1 x long 2 x long 3 x long 6 x long The entered code is wrong EIN ON key pressed while blocked This signal sounds after entering the correct numerical code after the lock has been manipulated blocked status Coding process incorrectly performed The old code remains valid The batteries have to be replaced The fault detection routine of the electronic lock has discovered a defect Please contact your distributors service department even if the electronic system continues to operate perfectly PROGRAMMING A NUMERICAL CODE OR CHANGING OF THE MASTERCODE BY MEANS OF THE MASTERCODE WHEN CHANGING THE NUMERICAL CODE MAKE SURE THE DOOR IS OPEN AND BLOCKED DO NOT ENTER PERSONAL DATA such as your birthday Ifthe set numerical code is lost it is only possible to open the safe or strongroom by using the mastercode or another valid standard code Therefore DO NOT FORGET THE NEW NUMERICAL CODE KEEP IT IN A SAFE PLACE page 2 As long as the mastercode is set to the factory setting 1 23 45678 9 it is not possible to program a 6 to 8 digit standard code Therefore during initial commissioning of the lock change the mastercode before keying in any standard codes Press the EIN ON key Key in the 9 figure mastercode If you have selected an opening delay of 0 minutes proceed with step 4 Press the ENTER key once and wait for the opening delay t
4. o lapse Following that press the ENTER key once more whilst the short high piched signal tones are sounding Now enter your mastercode once more Hold the ENTER key pressed down 6 seconds until you hear a long high pitched signal tone Enter 0 if you want to change the mastercode 9 figures or any number between and 9 if you want to change a standard code Press the ENTER key Now key in your new code 6 to 8 figures for a new standard code or 9 figures for a new mastercode Press ENTER key Key in the new code once more Press ENTER key If you have performed the coding process correctly you will hear 2 long high pitched signal tones The sounding of two long low pitched tones indicates that you made a mistake entering the numerical code Please start over at 1 TEST TO BE CARRIED OUT WITHOUT FAIL It should not be possible to turn the lock handle half a turn with the door open and blocked Press the EIN ON key key in the new numerical code and press the ENTER key It should now be possible to open the lock by turning the lock handle half a turn DELETING A STANDARD CODE Proceed exactly as indicated under programming a numerical code by means of the mastercode until step 6 Instead of keying in the new numerical standard code enter the figure 0 ten 10 times in a row complete by pressing the ENTER key The previously selected combination is now cleared and a new combination can only be coded by means of the mas
5. s the EIN ON key key in the new numerical code and press the ENTER key It should now be possible to open the lock by turning the lock handle half a turn CHANGING THE OPENING DELAY Press the EIN ON key Key in the mastercode If you have selected an opening delay of 0 minutes proceed with step 4 Press the ENTER key once and wait for the opening delay to lapse Following that press the ENTER key once more whilst the short high pitched signal tones are sounding Now enter your mastercode once more Hold the ENTER key pressed down 6 seconds until you hear a long high pitched signal tone Enter the 0 Press ENTER key Key in the two figure number 60 Press ENTER key Enter the new opening delay of your choice by keying in any two figure number between 00 and 99 This entered number is the opening delay in minutes Press ENTER key If you have performed the coding process correctly you will hear 2 long high pitched signal tones The sounding of two long low pitched tones indicates that you made a mistake entering the numerical code Please start over at 1 Entering an opening delay of 00 implies that the safe or strongroom is to be operated without delay in other words the first entry of the correct numerical code factory setting will open the lock page 4
6. system blocks the safe for a further twenty minutes ifthe entered number is wrong again manipulation security During this waiting time the safe cannot be opened even if the correct combination is keyed in The end of the blocking time is indicated by two short high pitched signal tones If more than 30 seconds lapse between keying in two numbers the electronic system will switch itself off for security reasons The opening or number coding process will then have to repeated from the beginning The stored data are not lost in the event of a power failure REPLACING THE BATTERIES If after switching on the electronics there is a signal of 3 x long low pitched tones the batteries have to be replaced There is still sufficient energy left to open the safe another fifty times approx imately The numerical code cannot be changed as long as the batteries are running low To replace the batteries enter a screwdriver in the top and bottom side slots and lift offthe top and bottom cover plates Insert four leakproof batteries type Mignon LR 6 alkaline In U S four AA type batteries Make sure the old batteries are disposed of in an environmentally safe manner LIST OF THE VARIOUS SIGNAL TONES High pitched tones 1 x short 2 x short 1 x long 2 x long EIN ON key pressed or bolt mechanism unblocked End of blocked status ENTER key pressed for six seconds start of coding mode Coding process
7. tercode CHANGING A NUMERICAL STANDARD CODE WHEN CHANGING A NUMERICAL CODE MAKE SURE THE DOOR IS OPEN AND BLOCKED DO NOT ENTER PERSONAL DATA such as your birthday Ifthe set numerical code is lost it is only possible to open the safe or strongroom by using the mastercode or another valid standard code Therefore DO NOT FORGET THE NEW NUMERICAL CODE KEEP IT IN A SAFE PLACE Press the EIN ON key Key in the old numerical code If you have selected an opening delay of 0 minutes proceed with step 4 Press the ENTER key once and wait for the opening delay to lapse Following that press the ENTER key once more whilst the short high piched signal tones are sounding Now enter your old numerical code once more page 3 Hold the ENTER key pressed down 6 seconds until you hear a long high pitched signal tone Enter 1 or 2 3 9 if you hold the first or second third ninth combination Press ENTER key Now key in your new combination of 6 to 8 figures e g 2 4 73 5 8 Press ENTER key Key in the new combination once more Press ENTER key If you have performed the coding process correctly you will hear 2 long high pitched signal tones The sounding of two long low pitched tones indicates that you made a mistake entering the numerical code Please start over at 1 TEST TO BE CARRIED OUT WITHOUT FAIL It should not be possible to turn the lock handle half a turn with the door open and blocked Pres
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 XL-6100 設置ガイド C-5113 取扱説明書 PPT 2 8 0 0 S eriesfor P ocket PC 2 0 0 2 KBS Tiefkühltruhe Jade Bedienungsanleitung Digitus RJ45 / SC Feed-forward Control System for Fed Voir la notice Infotainment Radio Blues Bedienungsanleitung 「ハンドブック」をダウンロードする Copyright © All rights reserved.