Home
Installation and operating instructions
Contents
1. Lg ed 2 hook and loop tape aquastop aquastop sensor Positioning of the aquastop sensor Please check the function of the aquastop sensor by starting the dishwasher washing machine When the solenoid valve of the aquastop is opening a wireless signal should reach the control unit to open the shut off valve blue light should light up The sensor must be located on the magnetic field generated by switching the aquastop solenoid valve when opening Please see the 2 mounting positions shown hook and loop tape Rev en 2014 02 12 Page 19 of 39 SYSTEMS water leak protect Flow sensor with transmitter Install the flow sensor transmitter near the water supply valve to be controlled in a position determined before by checking the wireless transmission range using the remote control Connect the 5V DC power adapter The flow sensors are available with 4 x threads or x threads 34 female x 34 male male x male Please consider flow direction arrow when installing flow sensor When turbine of flow sensor starts turning magnetic impulses will be detected by sensor The transmitter sends an opening signal to the control unit the green LED is continuously on while turbine is turning When turning of turbine is stopped green LED will start to blink 2 minutes after the turbine has stopped the transmitter will send a closing signal to control unit Rev en 2014 02 12 Page 20 of
2. Installation and operating instructions PIPESYSTEMS Pipe Systems GmbH Tel 49 0 42 61 85 157 0 Gro e Stra e 14 Fax 49 0 42 61 85 157 29 D 27356 Rotenburg W mme E Mail info pipesystems eu water leak protect INDEX INTRODUCTION ea aan een 0 Functional characteristics anne 6 Technical advantages of the system u een 7 COMPONENTS OF STE E 8 Valve with electric actuator and pressure SENSOP cccccseseccccsececceeccccesececsusececeenececeeeeeeeseusecetseneees 8 OO RI ee esse snc ectsaiee cron geeais ducetue coneonmetssaecigesoseganes E E 8 GOWNS CONG ee ee ee 9 Aquastop sensor with transmitter su een su ae 9 FIOW sensor With transmitter ass 10 Watersen or WINTER er 11 REMIOLE CO CFO Sirs ns ee ee tom re re nee 11 DESCRIPTION OF FUNCTIONS OF COMPONENTS cccscscsccscsccccscsccscscsccscscsccscscsccscscsscscso L2 OF OL Er ee ee ee 12 Pre FELSEN Or ee ee ee ee ee 13 MOLOMOELEO en ee ee 13 BE De E E A eree 13 Aquastop sensor with transmitter ess usssssssssessnensnesnnnnnennnnnnnnnnnnnnennnnnnennnnnnnnsnnnnnnsnnnsnensnnsnnnsnnnnnennn 13 FIOW sensor With transmitter ae u 13 Water sensor WIEN TLraNSMItler een 13 POWER CM DE ei ee here 13 FRE VINO Le CO ee 13 INSTALLATION PROCEDURE ccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccs LO SEO aC asses epee cern ate setae a E A EE S E EE E EAE E EEE ET 14 Preparations for installing sensors transmitters
3. Motion detector The motion detector detects the presence of a person and sends wireless signals to the control unit There are 2 models of motion detectors available either with 10 or with 20 or 30 minutes follow up time see page 15 Batteries The 3 x 1 5 volt batteries are required as power supply for the detectors and remote control Aquastop sensor with transmitter The aquastop sensor detects the magnetic field of the aquastop solenoid valve and sends wireless signals to the control unit to open close the shut off valve Flow sensor with transmitter The flow sensor detects the opening of the water supply valve for dishwashers washing machines hygienic water circulation side by side refrigerator outdoor faucets etc and send a wireless signals for opening closing of the shut off valve Water sensor with transmitter When the water sensor detects water the transmitter sends a wireless signal to the control unit and triggers the alarm Power adapter 5V DC Power adapter 5V DC for aquastop sensor and water sensor Remote control With the remote control the stop valve opens for the time period chosen Rev en 2014 02 12 Page 13 of 39 IPESYSTEMS water leak protect INSTALLATION PROCEDURE Sequence 1 Set up of transmitters Installation of ball valve and actuator Installation of control unit Installation of transmitters Final test AE E i Preparations for installing sensors transmitters and control
4. Stopping holiday mode Please press the red reset key for more than 5 seconds 3 beeps are following and the red light starts to blink in a 1 second interval The control unit is back in normal working condition Remarks The holiday mode can also be used to close the stop valve in case of an emergency when the system is connected to the normal power supply The time from the first pressing of the red reset key until the final closing of the shut off valve is max 23 seconds In case of an emergency and without electric power please follow the manual override instruction printed on the actuator Rev en 2014 02 12 Page 23 of 39 IPESYSTEMS water leak protect Water required outdoor Use flow sensor with transmitter for controlling the valve for the outdoor water supply Filling of large containers For the water supply to outdoor taps hydrants and faucets please use the remote control and press the buttons 0 5h 1h or 2h for time period water is required If you have for example pushed the button 0 5 h but then decide you want water for 1 h please press the button 1h and from the time you press the button the valve will be opened for the 1 hour The originally chosen time is deleted Note the alarm will be triggered when the time selected has elapsed and the faucet tap is not closed SERVICE Control unit Check on pressure drop alarm once a year Remote control and motion detectors Change batteries once a year REMARKS
5. blue light off The red light blinks and an audio signal is given In case of an alarm the red reset key can be pressed and the control unit is back into normal working condition Fault condition 1 All lights are off wv It can be that the power supply is interrupted Please check the power supply and the power adapter Mf 2 The blue lights are on No water flowing the control unit goes into alarm and the blue lights are off A leakage might be in the piping system Please check whether all faucets taps and outside faucets hydrants etc are closed If no faucet or tap is open there is a leakage M 3 The red light blinks in intervals and the control unit does not operate The control unit has an internal problem and has to be replaced M Rev en 2014 02 12 Page 27 of 39 PIPESYSTEMS water leak protect Motion detector Normal working condition If you come into the sight field of the motion detector the green light blinks in intervals as long as the motion detector is detecting a motion in its sight field At the same time a wireless signal is sent to the control unit to open the shut off valve After the motion detector does not detect the presence of a person any longer it sends a closing signal after the follow up time has elapsed Fault condition The green light is off 1 The valve does not open when there is a person in the sight field of the motion detector Alternative 1 T
6. 39 PIPESYSTEMS water leak protect Water sensor with transmitter Install the water sensor transmitter in the position you have checked before using the remote control for the wireless transmission range Please consider that metallic parts could interfere with the wireless transmission Install the water sensor upright as shown above picture left top or flat horizontally on the floor picture right top in the area to be controlled Connect the 5V DC power adapter Please consider that the 2 pins of the water sensor do not have any electrical contact to the wall floor The wall mounted position should allow for the distance between the floor and the 2 pins to be approx 1 1 5 mm see picture below transmitter power adapter input 230V AC output 5V DC N water sensor m distance to floor 1 1 5 mm N J Rev en 2014 02 12 Page 21 of 39 PIPESYSTEMS water leak protect Motion detector We supply motion detectors with a follow up time of 10 20 or 30 minutes Once the detector does not detect the presence of a person any longer 10 20 or 30 minutes will elapse before the motion detector sends a closing signal to the control unit We recommend 10 minutes follow up time for kitchen guest toilet etc and 20 or 30 minutes for a bathroom wall mounting ceiling mounting Full room control i e bathroom guest toilet The motion detector registers the presence of a person in its
7. Notes on safety Never put a finger into the ball valve when actuator is mounted Batteries Please use the ready available standard batteries type AAA 1 5 V 10 5 x 44 5 mm long Please use only leak proof new alkali manganic batteries When mounting the batteries please check for the correct mounting as per the printed instruction in the battery compartment Batteries may contain toxic substances Keep in mind the rules for waste removal of the makers Wall sockets Please use the power adapters supplied by us only on certified and approved wall sockets Rev en 2014 02 12 Page 24 of 39 PIPESYSTEMS water leak protect Wireless transmission Our system is using the 868 MHz ISM band The signals are transmitted on a straight line in all directions The installed transmission power is sufficient for normal homes Metal sheets or very thick armored concrete can disturb the wireless transmission and can reduce the range of the wireless transmission Electricity consumption Control unit 24V AC lt 1W Actuator only when operating Flow sensor Water sensor Aquastop sensor Motion detector Remote control 3 Batteries 1 5V AAA lt 0 00005 W Rev en 2014 02 12 Page 25 of 39 SYSTEMS water leak protect EMERGENCY Manual override Please follow the instruction printed on the cover of the actuator PIPES YSTEMS Manual operation in case of power blackout J 1 Loosen knurled screw l D L
8. drop please check whether all faucets taps or other valves are closed If this is the case then there might be a leakage In this case please proceed as follows Stop the alarm by pushing the red reset button on the control unit Open the shut off valve by using the remote control and check on the water meter whether there is a flow of water If this is the case and all faucets taps and other water outlets are closed then there should be a leak In this case please close the shut off valve by starting the holiday mode on the control unit by pushing the red reset button for 5 seconds until the beep signal for the holiday mode is starting see page 30 Call a plumber to locate the point of leakage and to stop the leakage In case the water meter does not show water flowing the alarm could have been triggered by a dripping faucet or the toilet flushing system having a small leakage or a leak in the pipe system In this case please call your plumber for checking on this leakage Tip for the plumber To open the shut off valve please finish the holiday mode by pressing the red reset button on the control unit for 5 seconds until the audio signal starts see page 30 Now you can open the shut off valve by using the remote control Rev en 2014 02 12 Page 35 of 39 SYSTEMS water leak protect TECHNICAL DATA Ball valve Nominal size DN25 Rp 1 Working pressure 10 bar Temperature max 75 C Bore amp 20mm Medium cold warm
9. of the programming cable connected to the control unit with the water sensor transmitter After 5 seconds an audio signal will indicate that the initialization procedure has been completed Disconnect the water sensor transmitter from the programming cable For checking the function of the water sensor please hold the two pins of the water sensor into a glass of water The audio signal will indicate the alarm status Press the red reset key on the control unit to stop the alarm Please repeat this procedure for every further water sensor transmitter Setting up of motion detector Check whether you have the right motion detectors motion detector with 10 minutes follow up time for kitchen and guest toilet 20 or 30 minutes follow up time for bathroom and shower Please insert batteries in the compartment on the backside of the remote control unit as illustrated Connect the free end of the programming cable on the control unit with the motion detector After 5 seconds an audio signal will indicate that the initialization procedure has been completed successfully Please disconnect the motion detector from the programming cable and repeat this procedure for any further motion detector required Rev en 2014 02 12 Page 15 of 39 water leak protect CHECK ON WIRELESS TRANSMISSION RANGE Please check the wireless transmission range of each sensor with transmitter Install the control unit and shut off valve with the electric actuator as de
10. unit Prior to the installation of the components same have to be initialized For initializing you require 2 power sockets with 230 V AC and batteries for the motion detectors and remote control Place all components in front of you Setting up of control unit Connect the power adapter 24 V AC with the control unit right picture Plug the programming cable into the socket of the control unit and leave the programming cable plugged into the control unit until all sensors and transmitters have been initialized and tested Plug the power adapter 24 V AC into the 230 V AC socket Setting up of remote control Place the remote control with the back side up in front of you Open the battery compartment and insert batteries as illustrated Close the battery compartment Put the remote control in front of you so that you can push the buttons For the control function push the button marked 0 5 h Now the green light should blink in short intervals Connect the free end of the programming cable connected to the control unit with the remote control After 5 seconds an audio signal is indicating that the initialization has been completed successfully Disconnect the programming cable from the remote control Press the button off and then the button 0 5 h Now the blue light on the control unit should be on When you push the button off the blue light on the control unit should go off The remote control is now set up and tested Plea
11. water Flow rate Pressure difference 1 00 2 00 3 00 4 00 5 00 6 00 7 00 8 00 9 00 10 00 11 00 12 00 13 00 14 00 15 00 16 00 17 00 18 00 flow rate Flow rate kv value Kv 18 0m h flow rate at a pressure difference of Ap 1bar Actuator Power supply 24V AC Torque 2 5 Nm Protection IP 31 Running time 15 18 seconds for 90 turn Rev en 2014 02 12 Page 36 of 39 PIPESYSTEMS water leak protect Pressure sensor Size G male thread Working pressure 10 bar Power supply 5V DC Wireless transmission between transmitters and control unit Radio frequency 868Hz ISM band Transmission power 5dBm ca 3 16mW Control unit Power supply Power adapter 230V AC input 24 V AC 750 mA output Plug 5 5mm 2 1mm pin Power consumption lt 1W Power supply actuator 24 V AC 300 mA 24 V AC 380 mA lt 60 seconds Protection of electronic and motor resettable fuse Aquastop flow and water sensor with transmitter Power supply Power adapter 230V AC input 5V DC 500 mA output Plug 5 5mm 2 5mm pin Power consumption lt 1W Remote control and motion detector Power Supply 3 Batteries 1 5V AAA Working condition of electronic parts Working temperature O C up to 40 C Stock temperature 20 C up to 70 C Humidity on working condition 10 up to 85 not condensing Humidity in stock 5 up to 90 not condensing Rev en 2014 02 12 Page 37 of 39 SYSTEMS
12. water leak protect DIMENSIONAL DATA Ball valve with actuator ei f T aM K H vam W Sr Al SEIS f OIII MES i TN N b RER II ZI ZZAN YS NN N DIN EN 10226 Rp 1 DIN EN 10266 5 4 h The distance of 60 mm between the wall and the center of the pipeline has to be kept so that the manual override function is guaranteed min 60 mm distance between wall and pipe Rev en 2014 02 12 Page 38 of 39 PIPESYSTEMS Components of system dimensions weights Length Width Designation Ball valve Actuator Pressure sensor Control unit Aquastop sensor with transmitter Water sensor with transmitter Flow sensor with transmitter female x 2 male Flow sensor with transmitter female x male Motion detector with 10 minutes follow up time Motion detector with 20 minutes follow up time Motion detector with 30 minutes follow up time Remote control Power adapter 5V DC Power adapter 24V AC Programming cable Extension cable For control unit 5m for power adapter 24V AC 10 m for power adapter 24V AC For pessure sensor 5m for pressure sensor 10 m for pressure sensor For actuator 5m for actuator 10 m for actuator For transmitter 3 m for power adapter 5V DC 5 m for power adapter 5V DC waterleak protect Art No Height Cable mm length mm mm sooo BE Weight g piece 530 g 50020 45cm 360g cm g ees en 6
13. 5 azo 8s 25 105 g 50070 95cm cm 858 50100 1735 5 20 908 86g 500o TB em 50150 50160 50151 50161 50152 50162 50163 50164 5 5x2 1mm 5 5x2 1mm 5 5x2 5mm 5 5x2 5mm We reserve the right to amend technical data Rev en 2014 02 12 SYSTEMS 5m 10m 5m 10m 5m 10m 3m 5m Page 39 of 39
14. al override description are visible Please consider the arrow on the valve body showing the flow direction In case the flow direction is from the opposite side please install the valve and actuator as shown in picture 2 and loosen the knurled screw Take off the actuator turn same by 180 remount same and tighten the knurled screw Please consider that the manual override description and the knurled screw is always good visible for the person doing the installation After this installation has been completed the pressure sensor can be mounted Picture 1 Picture 2 actuator actuator pressure Sensor PIPESYSTEMS t O oona PIPESYSTEMS Manuelle Betaotigung 2 bei Stromausfall t y T Gerac Jude 5 r IT 3 9 ia flow direction knurled screw shut off valve shut off valve knurled screw flow direction Upside down mounting is not permitted PE ARE SWALSAS dja Rev en 2014 02 12 Page 17 of 39 PIPESYSTEMS water leak protect Mounting of wall plate For all transmitters except the remote control wall plates screws and plastic sockets as well as glue tapes are included These wall plates should be fixed by a screw or the adhesive Strip aan Control unit Please install the control unit right next to the ball valve and actuator Please check whether the connecting cables are long enough for the installation position of the control unit to the actuator and pressure sensor Please consider
15. and control unit ssssssssssssrssssrrserrserrrerrrrerrrerrreens 14 SENE POTON O UNIN ee een tees 14 Seltine up of remote Con Ol ee er een 14 Setting up of aquastop and flow sensor with transmitter cesssssesnsenesnssnennnnennnnnennnnnennnnnennnnennn 15 Setting up of water sensor with transmitter eesssssesnsssesnsnnsnnnnennnnnennnnnennnnnnnnnnennnnnennnnnennnnnnnnnnennn 15 Setting up of motion detector nn 15 CHECK ON WIRELESS TRANSMISSION RANGE ccccccccccccccccccccccccccccccccccccsccccccccccccsssssseee LO INSTALLATION OF COMPONENTS nennen Ball va NE WIEN CU ACO ee ces Se cc ees se ese ca ee er ee 17 MOUNEINE OF wall SE er AE 18 CORE Se ee 18 Rev en 2014 02 12 Page 2 of 39 SYSTEMS water leak protect AGU ESTOD sensor With Transmitter eu ee ireieeh 19 Flow sensor With Ces Mittler een ee ee 20 Water sensor with transmitter essssessseessnesssnnesnnnnnnnnnnnnnnnnnnennnnnnnnnennnnnnnnnnnnnensnnennnnensnnensnnsnsnnensnnrnnn 21 MO OMO ECTO nee re ee ee 22 Full room control i e bathroom guest toilet cc ceeseccceceeeseccceeeeesececeseeeeecseseeneceeeeaenseess 22 Part room control i e kitchen taps individual FAUCETS ccceccccccesssecceeeeeeeeeceeeeeeseceeeeeeeneess 22 Check on detection area of motion detector cccccsssesccccceessececcceeseccccseauseccesauausceeeseaaeeeeesaaaaeees 23 FIRE S05 ee ee ee ee 23 Water sensor WIEhTLAnSMItler en hkeenee 23 Pressure sensor check press
16. d Battery low on motion detector or remote control Repeated E 5seconds pause M Rev en 2014 02 12 Page 33 of 39 PIPESYSTEMS water leak protect Holiday mode Actuator is closing valve shut off Repeated until valve is closed Valve closed 3 seconds beep Holiday mode stopped Water sensor Alarm Water flood alarm Repeated as long as sensor is detecting water Rev en 2014 02 12 Page 34 of 39 PIPESYSTEMS water leak protect PROCEDURE IN CASE OF ALARM There can be 2 types of alarm Alarm triggered by water flood An alarm is triggered when the water sensor is in contact with water In case you have more than 1 water sensor installed you can identify the water sensor which has triggered the alarm by checking for the water sensor and transmitter with the audio and light alarm signal see pages 29 30 Check for the cause of the water flood stop the water flood and dry the 2 contacts of the water sensor The audio alarm signal of the water sensor transmitter stops Stop the alarm by pushing the red reset button on the control unit The audio alarm signal on the control unit stops and the system is back in the normal working condition Alarm triggered by pressure drop If an alarm is triggered by a pressure drop a beep and light alarm signal on the control unit is triggered see pages 29 30 In this case the control unit automatically is closing the shut off valve In order to find the reason for the pressure
17. ee ee ee 28 FA ECO a en ee N 28 Water sensor with transMitter cccccccccsssssssseecccccsceeessececccessseeeseeecceessseeesseeceeeesssueaaseeeseesesaaegsgses 29 Normal Working CONAN ION ee en ee ee 29 FAUL ECO IO ee ee ee E 29 Aquastop sensor with transmitter sense een 30 Normal working CONAN eu 30 FOIE cOn d O Wisse ee an hav ott ee ee Eee ee E 30 FIOW SENSO WICH Transmitter nennen ee 31 Normal Working Condition 31 FAUL ONIONS ee ee 31 PRS ORS COMTO en E E EE A E A E E E 32 N rmalworking CONd ION een een here 32 F AUC COM GITIOU AAEN EEEN AA EE EA EET E A E E EN E A T EEE 32 CONT OU oe ee ee E E eeeies 33 Ea ee ee ee ee 33 Warning peep signals wcicscicssdececesiencadsecnsmnasossewedoarndeataiounidimanoeaaiedeasnahewadosaydounedimeesanitadwaroneaoateuaGedens 33 PONIO Senne ee ee ee 34 Wat T NSO ee eher 34 PAT 1 E E NE canon ET EA ENE T E A AEEA AA EN 34 PROCEDURE IN CASE OF ALARM AE N E E EE E E E sD Alarm a 24241 26 Dy Water 1 004 ee ee er eine 35 Alarm triggered by pressure drop cccccccsssecccceseccccesececeusececeenecceeeusecessusecessuneceesensecessenecessenecetseges 35 TECHNICAL DATA rrr ETE tic saisendiestuiewececes sebecsoscdavecceseneaceeesessnes ease 5 2721 VAIN EEA AE A ET EA E A A A E T 36 ACETON ee ee eee ee rec nee i ee ee ee ere 36 FOSS UME S SeN ON aie sate tins sec ee ee ae ee er 37 Wireless transmission between transmitters and control unit cccccessssceccceeseeeeeeeeeesecee
18. em and has to be replaced control light green programming connnector power adapter 5V DC sv DC OGO aquastop sensor Rev en 2014 02 12 Page 30 of 39 PIPESYSTEMS water leak protect Flow sensor with transmitter Normal working condition The green light blinks in intervals When the sensor detects the opening closing of the valve controlled the transmitter sends a wireless signal to the control unit to open or close the shut off valve Fault conditions 1 The green light does not blink in intervals Please check on the power supply 2 The transmitter sends a signal but the control unit does not react Please check the radio range from the position the flow control sensor with transmitter is installed to the control unit by using the remote control 3 The green light blinks in quick intervals and the flow sensor does not show any reaction The transmitter has an internal problem and has to be replaced control light green programming connector u je svpc OG Ra NS power adapter 5V DC cable to flow sensor female x 3 4 male or 2 male x male flow sensor male x Ya male kz 7 cable to flow sensor transmitter female x male Rev en 2014 02 12 Page 31 of 39 PIPESYSTEMS water leak protect Remote control Normal working condition Inthe normal condition the green light is off When you push one of the 3 buttons the
19. esseaseeess 37 CORE ee ee nee ee ernehere 37 Aquastop flow and water sensor with transmitter esssessesssesseesnsnsnesnnnnnnnsnnnnnnnnnnnnennnnnnnnsnnnnnenen 37 Remote control and motion detector cc sseccccccsssssecccceesseccccssessecccessauececeseuasecesssuaueceesauaneeeeeeaas 37 Working condition of electronic parts cusss22ssessnensnesnnnsnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnsnnnnnennnnsnnnsnnnnnennsnnnnn 37 DIMENSIONAL DATA sssssssssssssossssssosossssssssssosssossososossssssosossssssssssosssssssssssssssssessss SO Rev en 2014 02 12 Page 4 of 39 IPESYSTEMS Ball Va VEN SEO ee ea 38 Components of system dimensions weights ueeeeesssssssnnnnnnnnnnnnnnnnnnnnenenensnnnnnnnnnnnnnnnnnnnnnnnnnne 39 EXTENSION SI ee ae ee oe ee ee 39 Rev en 2014 02 12 Page 5 of 39 PIPESYSTEMS water leak protect INTRODUCTION ater ieak protect dishwasher washing machine YD remote control ZZ y motion detector JE 3 L transmitter A guest toilet outdoor taps P aqua stop sensor E flow sensor EP water sensor bathroom control unit pressure sensor Wee actuator stop valve water meter Functional characteristics The shut off valve is in the closed position and will open and shut on wireless signals The motion detector detects the presence of a person and sends a wireless signal to the control unit the shut off valve opens Once the
20. he batteries can be empty Please use new batteries Alternative 2 The motion detector is out of wireless range Take the remote control and check whether the wireless signals are reaching the control unit from the location the motion detector is placed While making this test no other sensors should be active by sending an opening signal to the control unit Please make sure that all other sensors do not send any opening signals during this test 2 The green light is blinking in short intervals and the control unit does not react The motion detector has an internal problem and has to be replaced Please consider the follow up times programmed Rev en 2014 02 12 Page 28 of 39 n p PIPESYSTEMS GMBH water leak protect Water sensor with transmitter Normal working condition The red light blinks in intervals When the 2 ends of the pins of the water sensor are electrically bridged the red light will be on and an audio signal is sent as long as the 2 pins have an electric contact The transmitter sends a wireless alarm signal to the control unit and the valve closes Fault condition 1 The red light does not blink in intervals Please check on the power supply 2 The red light is blinking and the audio signal is sent Possibly the 2 pins of the sensors are bridged by cleaning fluids Please dry the 2 contacts with a paper tissue 3 The water sensor is detecting water but the control unit does not react Please c
21. heck the wireless transmission range from the installation position of the water sensor transmitter to the control unit with the remote control 4 Thered light is blinking in short intervals and the water sensor shows no reaction The water sensor has an internal problem and has to be replaced control light red programming connector power adapter 5V DC water sensor Rev en 2014 02 12 Page 29 of 39 PIPESYSTEMS water leak protect Aquastop sensor with transmitter Normal working condition The green light blinks in intervals When the sensor detects the magnetic field of the solenoid valve on the aquastop the green light is on as long as the magnetic field is detected by the sensor and the transmitter sends a wireless signal to the control unit to open the shut off valve Fault condition 1 The green light does not blink in intervals Please check on the power supply 2 The green light is not on despite the aquastop magnetic valve opens It can be that the sensor is not placed in the right position on the magnetic field of the solenoid valve Please re position the sensor 3 The transmitter sends a signal but the control unit does not react Please check using the remote control the radio range from the position the aquastop sensor with transmitter is installed to the control unit 4 The green light blinks in quick intervals and the aquastop sensor does not show any reaction The aquastop sensor has an internal probl
22. ift actuator approx 7 mm from ball valve so that the 2 protruding knobs on the neck of the ball valve are clear for 90 right turn 3 90 right turn Power blackout In case water is required during a power blackout the shut off valve can be operated manually see manual override instruction printed on cover of actuator Please consider that the system in this manual override open condition does not protect against leakage Please put the system back into normal working condition after the power is back Leakage Please call the plumber when there is a leakage When system is in alarm condition please do not use manual override because water flood could happen In case of a defect on the control unit or actuator Please disconnect the power adapter and use the manual override function if water is required Please call your plumber for service Rev en 2014 02 12 Page 26 of 39 PIPESYSTEMS water leak protect TROUBLE SHOOTING Control unit Normal working condition When the green light is on the power supply is connected When the red light blinks in intervals the system is in working condition When a wireless signal is received by the control unit from a sensor the valve is opening blue light is on When the control unit receives a wireless signal to shut the valve will be shut blue light is off When an alarm is triggered by a water sensor or the pressure sensor when valve is closed the valve will remain closed
23. motion detector does not detect the presence of a person any longer it sends a wireless closing signal The aquastop sensor detects the magnetic field of the solenoid valve mounted on the dishwasher or washing machine and the transmitter sends a wireless opening signal to the control unit to open the shut off valve After the solenoid valve is closed a wireless closing signal is sent to close the shut off valve Rev en 2014 02 12 Page 6 of 39 PIPESYSTEMS water leak protect The flow sensor detects opening and closing of the water supply valve for dishwashers washing machines hygienic water circulation side by side refrigerator outdoor faucets etc and sends a wireless signal for opening closing of the shut off valve The transmitter of the water sensor sends a signal to the control unit to close the shut off valve when water is detected The remote control is used for opening the shut off valve for outdoor faucets taps and hydrants The pressure sensor constantly checks the pressure in the system and keeps the shut off valve closed when a pressure drop is detected and triggers a beep and light signal The alarm condition can be stopped by pressing the red reset key on the control unit Technical advantages of the system Reduction of open times of shut off valve to the times water is needed Reduction of time in which a water leakage can occur in the piping system controlled by the water leak protection system Alarm is t
24. nd the plug mounted on the cable has to be plugged into the socket marked sensor Programming socket This programming socket is required for programming the control unit and connecting the control unit with the transmitter sensor by using the programming cable Reset key By pressing this reset key for a short period of time you can stop the alarm condition Pressing this key for a longer time you start the holiday function Control lights Green light is signal for Power On Red light has 3 working conditions blinks continuously in short intervals control unit is working everything is okay e blinks in longer intervals with audio signal alarm is triggered blinks in very short intervals there is a fault in the control unit Blue light shows the shut off valve is open or is opening Rev en 2014 02 12 Page 12 of 39 SYSTEMS water leak protect Audio signal The audio signal in connection with the red light indicates the alarm condition After programming the control unit with a transmitter using the programming cable a short audio signal indicates the completion of the initialization Ball valve with actuator The ball valve with the actuator opens closes the water supply line Power adapter 24 V AC This power adapter supplies the power for the control unit Pressure sensor The pressure sensor continuously checks the line pressure and sends signals via the cable connection to the control unit
25. r so that both are electrically bridged Now the alarm is triggered and the valve closes Pressure sensor check pressure drop test Please blind fold the optical sensor of a motion detector During this testing time please make sure that no other sensor of the system is sending wireless signals to the control unit in the period of testing Wait until the follow up time of the motion detectors has expired and that the control unit has closed the shut off valve and the blue light on the control unit is off Wait for another 20 seconds until the actuator has closed the shut off valve completely Open the faucet controlled by the blinded motion detector and simulate a leakage When the water pressure in the piping system drops within 10 minutes by 20 the alarm is triggered Please press the red reset key of the control unit to stop the alarm Take off the material with which you have blind folded the motion detector SPECIAL SITUATIONS Holidays If you stop the electricity supply during your holiday you will have to put the control unit into the holiday mode In the holiday mode the shut off valve is closed Starting holiday mode Please press the red reset key for more than 5 seconds The control unit will start to give a rhythmic audio signal Please wait until this audio signal is changing into a longer beep The red light is blinking now in a 3 seconds interval and the blue light is off In this mode you can stop the electricity supply
26. remote control sends a wireless signal to the control unit to open the shut off valve for the time period selected As long as the selected time is running the green light blinks in intervals After the time selected has elapsed the remote control sends a wireless signal to the control unit to close the valve Fault condition 1 You press one of the time buttons the control light does not blink in intervals and the valve remains closed This situation can be caused by empty batteries Please replace the batteries 2 You push one of the time buttons the control light blinks in intervals but the valve remains closed Possibly the wireless range is not sufficient Please reduce the distance between the remote control and the control unit or check wireless transmission range from another location 3 The green light blinks in short intervals and the remote control shows no function The remote control has an internal electronic problem and has to be replaced selection time period programming connector N battery case on backside Rev en 2014 02 12 Page 32 of 39 PIPESYSTEMS water leak protect BEEP SIGNALS Control unit Alarms Water flood alarm Repeated as long as alarm is on Pressure drop alarm Repeated as long as alarm is on Warning beep signals Pressure sensor voltage too low pressure sensor not connected or cable defect Repeated Pressure sensor voltage too high pressure sensor not connected Repeate
27. riggered in case the pressure sensor detects a pressure drop and the shut off valve will stay closed or will be closed Leakages in the controlled system will be detected immediately also the dripping faucet Wireless transmission 868 MHz ISM Band No pre selected opening times or flow rate System works full automatically Rev en 2014 02 12 Page 7 of 39 SYSTEMS water leak protect COMPONENTS OF SYSTEM Valve with electric actuator and pressure sensor electric actuator PIPESYSTEMS Ma zung 2 bei Stromausfall t 1 DE pressure sensor 2 3 knurled screw shut off valve arrow for flow direction Control unit control light red control light green working condition power control light blue electric actuator reset key programming connector for en power adapter 24V AC connector for connector for pressure sensor electric actuator Rev en 2014 0212 0000000 Page 8 of 39 PIPESYSTEMS water leak protect Motion detector sensor control light green batterie case programming on backside connector Aquastop sensor with transmitter control light green programming connnector power adapter 5V DC Lt Nb gt Bh die j Ban aquastop sensor Rev en 2014 02 12 Page 9 of 39 PIPESYSTEMS water leak protect Flow sensor with transmitter control light green programming connector power adapter 5V DC cable to flow sensor female
28. scribed in the installation instruction Pages 17 18 Take the remote control to check if the wireless signals from the remote control are being transmitted successfully from the installation position of each motion detector Push the 0 5 h button of the remote control and check whether the blue light on the control unit lights up and confirms the receipt of the wireless opening signal Please do this wireless range test for each installation position of any mounted transmitter sensor In case the wireless signals should not reach the control unit please check for possible metallic obstructions which could disturb the wireless transmission The installation position of the control unit may have to be changed in order to get a better wireless transmission range After this wireless transmission check has been completed the installation of the components can begin In case there are problems on the wireless transmission if control unit is mounted in the cellar please use 5 or 10 m long extension cables available for electric actuator and pressure sensor Rev en 2014 02 12 Page 16 of 39 IPESYSTEMS water leak protect INSTALLATION OF COMPONENTS Ball valve with actuator Please install the ball valve behind the shut off valve after the water meter or behind the pressure reducing valve and filter if same are installed in the system The ball valve and actuator should be installed as shown in picture 1 so that the knurled screw and the manu
29. se repeat this procedure for every further remote control you want to use Rev en 2014 02 12 Page 14 of 39 water leak protect Setting up of aquastop and flow sensor with transmitter Please connect the power adapter 5V DC with the transmitter The green light should blink regularly Please connect the free end of the programming cable connected to the control unit with the transmitter After 5 seconds an audio signal will indicate that the initialization procedure has been completed Please disconnect the transmitter from the programming cable In order to check the function of the aquastop and flow sensor please put the aquastop and flow sensor onto the surface of the power adapter 24V AC of the control unit If the sensor has detected the magnetic field of the power adapter the green light on the transmitter and the blue light of the control unit should light up Take the sensor away from the magnetic field of the power adapter The green light of the transmitter is now blinking in short intervals Please wait for approximately 30 40 seconds and the blue control light on the control unit should go off The aquastop and flow sensor with transmitter is now set up and tested Please repeat this procedure for every further aquastop flow sensors required Setting up of water sensor with transmitter Please connect the power adapter 5V DC with the water sensor transmitter The red light should blink in short intervals Please connect the free end
30. sight field Please choose the position for mounting so that the motion detector can control the area to be _ checked The final mounting position nn should be checked using the remote ca 2 5 m control checking for the wireless transmission range The sensor of the motion control can detect persons in a distance of approx 5 meters The sight field has an angle of approx 82 This means that the sensor mounted in a distance of 2 5 m can control an area of approx 5 6 meters am ca 5 6 mcr Part room control i e kitchen taps individual faucets You can reduce the sight field of the sensor with the sight shade Pull out or press this sight shade into the housing according to your requirements The more you pull the B sight shade out of the housing the sight shade protruding smaller the sight field of the sensor gets approx 4 mm Rev en 2014 02 12 Page 22 of 39 PIPESYSTEMS water leak protect Check on detection area of motion detector When the motion detector detects the movement of a person the green light is blinking in intervals This enables you to check on the sight field of the motion detector Final tests When all components of the system have been installed the following final tests should be carried out Water sensor with transmitter Please take a piece of tissue paper and dip same into water Please touch with this wet tissue paper the ends of the 2 pins of the water senso
31. that the cable connection between the actuator and the control unit has to be in a position that a manual override by turning the actuator 90 is possible see picture below and dimensional data sheet page 31 You need a 230 V AC power socket in reach of the power adapter 24 V AC power adapter control unit 24 V AC a n pressure sensor actuator ball valve r Connect the actuator with the control unit Connect the pressure sensor with the control unit Connect the power adapter 24 V AC with the control unit The green light on the control unit should be on and the red light should blink in short intervals The control unit is set up Rev en 2014 02 12 Page 18 of 39 PIPESYSTEMS water leak protect Aquastop sensor with transmitter Install the aquastop transmitter near the aquastop solenoid valve in the position determined before by checking the wireless transmission range using the remote control The best installation position of the transmitter is near the water inlet of the dishwasher or washing machine to be protected Please use an installation position considering that no metallic parts are disturbing the transmission of the wireless signals Fix the aquastop sensor in the area where the magnetic field of the solenoid valve is generated on the aquastop valve using the adhesive tape Connect the 5V DC power adapter aquastop aquastop sensor transmitter power adapter input 230V AC output 5V DC i ve os l
32. ure drop te St cccccccccccccccccceeeeeceeeeeeeeseeceeeceeccessseeeeeeeuueeeseesseeeeess 23 SPECIAL SITUATIONS esssesssosscsoscssscoscsosoosososcsosossesososssosoesosossssosososossesosossssssssossss LD ION ANGE ee E ee 23 Staltine NONA MOUE ee T 23 SCO OL NO SV Ge ee ee ee 23 ROIN RE ar paccaecnese uel E 23 Waer recule dout OT ee ee ee ee 24 FUME Gl WAS COMUNE a EA 24 SERVICE cnc scecesnaccecwsnascecsenecatensueseecesnessnensbescecssnesabensmsssecsaneatsensneaseciensdadesensasecene 4 FON ee 24 Remote control and motion CETECCOMS c cccccecececcececscsecececscsecececseseseeecscseseececscseneeenecseseeuecseseass 24 REMARKS ee ae Note DS Wa a meen ee E oe ea ee eee 24 572 E a ee ee en ee ee 24 WaN O KET re ee eher 24 Wireless ae ac MISSION eee ee enn eee E E ere 25 Electricity CONS UIMIDUION een 25 EIVIERGEINGY 0 ee na as essences aaa IM AWM OVS OS ae en el een Rense 26 POWERDIACKOUR er ee Dr A 26 ER ee ee E NEE 26 In case of a defect on the control unit or actuator uccceeeeeeessnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnsnnsennnnn 26 TROUBLE SHOOTING can nn na ae an aaa Tara 2 OTE Oo ME e Goneases stn cosuadeevadnnatediuce sc NRRERRENL ER RENEREN WERNER EIRUN E 27 Normal AV OG MS COM On ee ee ae ee een 27 FSU CO One ae ee ee 27 Rev en 2014 02 12 Page 3 of 39 SYSTEMS water leak protect MOUONTO TO en ee tn ater ems ere a ren ne are Be eee rer Te 28 Normal WOrKINE CoHd ONE
33. x male or 2 male x Ya male flow sensor 1 male x Ya male k a cable to flow sensor transmitter female x 3 4 male Rev en 2014 02 12 Page 10 of 39 PIPESYSTEMS water leak protect Water sensor with transmitter control light red programming connector power adapter 5V DC water sensor Remote control selection time period programming connector Ma battery case on backside Rev en 2014 02 12 Page 11 of 39 PIPESYSTEMS water leak protect DESCRIPTION OF FUNCTIONS OF COMPONENTS Control unit The control unit receives the wireless messages from the transmitters and activates the electric actuator of the ball valve accordingly The pressure sensor checks the line pressure continuously and when a pressure drop is detected while the shut off valve is closed an alarm is triggered with an optical and audio signal In this alarm condition the control unit is not accepting any signals for opening the shut off valve The alarm condition will remain active even after a power failure This alarm can be stopped by pushing the red reset key Power socket The plug of the power adapter 24 V AC has to be plugged into the socket marked Power 24 V AC Electric actuator The plug on the cable of the electric motor has to be plugged into the socket marked motor Pressure sensor The pressure sensor has to be screwed into the 1 1 4 female thread of the valve a
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 PF-P470 / PF-P450 個別カタログ: MP1591A ネットワークパフォーマンステスタ Manual de usuario de Banca por Internet Rentrée 2013 - Club Léo mare LS-372 - Commell MINI SENSORLESS BRUSHLESS MOTORS Notice d`utilisation Electrolux 2498-6 GA User's Manual Le groupe BeL en revue 202 - FISCAL.cdr Copyright © All rights reserved.