1. 7117 Electrical Connection Attention Prior to making the electrical connection of the Rittal CMC TC Display Unit Il the safety notes page 4 must be observed The Rittal CMC TC may be operated only with protective earth conductor The PE conductor connection is made by plugging in the C13 IEC connection cable This requires that the IEC connection cable is connected on the mains side with the PE conductor The electric supply voltage and frequency must correspond to the rated values Refer to the technical specifications page 7 Prior to working on the Rittal CMC TC system it must be made voltage free and protected against being switched on again Power supply The Display Unit Il is supplied with power from the Processing Unit I using the RJ12 interconnecting cable This means that you do not require any additional power pack Establishing the connection between the Processing Unit and Display Unit Il For this purpose use the RJ12 interconnecting cable contained in the scope of supply This cable is inserted in the RJ12 socket of the Display Unit Il and to the IOIOI connection of the Processing Unit II as shown in the figure below Display Unit Il Processing Unit II A Note Please note that you can only connect one unit to the IOIOI connection of the Processing Unit Il Namely either one Display Unit Il ISDN unit or GSM unit 8 17 Bedienung der Display Unit Il The display h
2. 450 7320 813 7320 100 Technical Specifications Housing Plastic covering with metal trim piece Height 1 U approx 4 45 cm Width approx 13 6 cm Depth approx 12 9 cm Weight approx 0 35 kg without packaging Potential equalisation Not required because 24 VDC protective low voltage Earthing Not required because 24 VDC protective low voltage IP protection category IP 40 to EN 60529 LED display blue white 122 x 23 Pixels Temperature range in operation Humidity range in operation Storage temperature range Voltage connection Power supply Fuses Power input Detector connection Installation Instructions 5 C to 45 C 41 F to 113 F 5 to 95 relative humidity non condensing 20 C to 60 C 4 F to 140 F 1x DC 24 V max current 3 A SELV Fine fuse T 3 A 250 V UL approval 50 mA 1x RJ12 sockets shielded The Rittal CMC TC Display Unit II must be installed in an enclosure or housing system that provides additional protection from external influences The cable lengths must not exceed the lengths given in the technical specifications in order to avoid losses due to unnecessary lengths of cables Attention must be paid to maintaining the permitted ambient temperature and humidity ranges as well as the IP protection category as required for the specific application The appropriate information is contained in the technical specifications page 7 7610 000
3. of the Rittal CMC TC system The Display Unit Il is connected to a processing unit and displays the current status of the CMC TC If an alarm is issued the message will be displayed in the display and the integrated alarm beeper will sound In addition the current values such as temperature current etc will be displayed appropriately for the monitoring application Features The Rittal CMC TC Display Unit Il is an independent device It has three keys and a LCD display on the front side The display has a resolution of 122 x 32 pixels Pushbuttons also located on the front side are used for the navigation The Enter key can be used to confirm the changed settings To acknowledge the alarm the C key should be pressed for three seconds The rear side has a RJ12 slot connected to the processing unit using the supplied interconnecting cable An additional power pack is not required because the display unit receives its power from the processing unit The Display Unit II can be attached with the supplied Velcro fasteners to the inner side of the side panel to the punched sections or to the component shelves of the enclosure The unit can also be attached using the DK 7320 440 or DK 7320 450 mounting units 3 17 A Safety Notes General notes Prior to the installation and the commissioning the installation and operating instructions must be read carefully and observed The installation and operating instructions contain basic informatio
4. Installation and Operating Instructions CMC TC Display Unit Il Computer Multi Control Top Concept Display Unit II DK 7320 491 Edition 1 March 2006 A36017 02 IT 74 Table of Contents ri tto CH CHO sae om otim e tee ee ee ee EE ME 3 DJOSCHDHOD uiii EHE IA HR RR rent etter rrr e 3 gue e C i 3 veley ol os nda ceases ane aad 4 General NOIES RR 4 Working on the Rittal CMC TC Display Unit ll sees 4 Operational reliability 2 2 2 1 ceo tecto are e rriernttooc rennen ance r ance er kara dn 4 UE Ta 2 ne gels Seep rr rer 5 eicere eee ee neem On REE RE SR FIC r tu 5 Blasi 5 Service and Service Address E E ETT E 5 SCOPE olio 1096 IY NERONE ITE EE ED 6 The following items are also required eessseeeeeneneeeee 6 Technical specie allois ose oe Penne rey o ortu eres on rdv On y oU ve yp I ON E RED 7 Installation MMSIUCHONG niione ainneartan aiea iaaiiai anai iiia 7 Electrical Connection casses cseteiut eset lot cete tesehe st eosete oc otskenc teret been tris Rossi Dee aeske Pu Renee Rd 8 POWOSUDDIVW 5G unastear strat Your Eae amare gee 8 Establishing the connection between the Processing Unit and Display Unit lI 8 Bedienung der Display Unit ll ssseseesseeesseeeeeeeeeeennnnn nennen 9 x during normal op
5. as a backlit LCD display with 122 x 23 pixel resolution Three keys are provided for its operation CMC TC Display unit II This key has the Change designation and is used to change or increment the values in the input menu This key has the Enter designation and is used to start menus and to call and terminate input functions This key has the Clear designation and is used to acknowledge alarm messages One of its functions is also to close the input menus If you press the key for longer than 2 seconds the Configuration change message on the processing unit can also be confirmed The display will be automatically recognised by the CMC TC Processing Unit after it is switched on If no login is performed from the Hyperterminal interface within 60 seconds a switch back to the display will be made 9 17 Display during normal operation The software version of the display unit will first be displayed when the display unit is connected to the operating voltage CMC TC DU V2 01 c 2006 by Rittal Once the display unit has been recognised by the processing unit the following messages will be displayed CMC TC PU main menu All sensor values analogue or digital that have been selected in the menu will be displayed alternately For example Temperatursensor 37 C Spannungswachter 1 switches to the main menu 10 17 Main
6. ded use The limits listed in the specifications see Technical Specifications page 7 must not be exceeded under any circumstances This applies in particular to the permitted ambient temperature range and the permitted IP protection category For applications with a higher specified IP protection category the Rittal CMC TC must be installed in an enclosure of a higher IP protection category that complies with the specified protection category The operation of the CMC TC system in direct contact with water aggressive media or inflammable gases and fumes is prohibited 4 17 Maintenance The Rittal CMC TC Display Unit Il is a maintenance free system The housing does not need to be opened for installation or during operation The opening of the housing or the accessory components will void any warranty and liability claims Cleaning The Rittal CMC TC Display Unit II can be cleaned using a moist cloth The use of aggressive substances such as white spirit acids etc can damage the system Disposal Because the CMC TC Display Unit II consists principally of the housing and the PCB the unit must be disposed of through electronic waste recycling when it is no longer required Service and Service Address If you have any questions concerning technical or other issues related to our product range RITTAL will be pleased to provide the required support You can also contact us at the following address RITTAL GmbH amp Co KG PM IT Serv
7. eration 3c erret ede ette tle tert decent decet edere ote 10 IEEE ELITS E E a A A EA sees AA AEEA 11 Malues SUDITIBEILS i iere siae OeD Dee De DCN EODeD pm e 12 Network Configuration submenu ssssseseeeeeeeeennnne nennen 13 System Information submenu eesssssssssssseeeseeee nennen nnne nnne nnn 14 Untermen Display Setup eee eeccccccceee eee eeeeeneaeeeeeeeeeeeeaaaaaaaaaeeeeeeeeeeeeeaaes 15 Logout Display submenu only applies to Processing Unit l 16 Alarm CISA yS casas snes cratenas oido cdi bod dotted Deed ded tet it tod 17 2 17 Introduction The stable flow of information and production is the lifeline of an enterprise Loss of data failure of function and production cause extensive and in many cases life threatening damage Consequently a declared company goal is to achieve the largest possible safety and reliability Rittal supports you By means of universal competence in effective prevention comprehensive safety and centralised organisation i e teamwork for IT safety and reliability This results in an optimum combination of enclosure monitoring server administration and climate control components The solution for the enclosure monitoring is Rittal CMC TC This concept covers the complete physical monitoring of the enclosure The system is rounded by its modular structure Description The device is used for the local optical display
8. figuration submenu This submenu is used to make the network settings of the Ethernet interface These settings are required for commissioning the CMC TC processing unit The following settings can be made Edit IP address 130 000 002 220 Edit Netmask 255 255 000 000 Gateway address 000 000 000 000 Enable DHCP enable disable selects the next subitem starts the input of the selected menu item If the input haz een started the first octet of the IP e44ress or subnet mask or gateway flashes sets this octet between 0 255 confirms the setting and switches tc 3 e next octet Once all octets have been entered closes the input switches the DHCP setting between disable and enable closes the menu and returns to the main menu Warning If a network setting has been changed a reboot of the Processing Unit will be performed in this case and the new network settings will be accepted 13 17 System Information submenu The following information for the CMC TC Processing Unit can be displayed in this submenu HW V3 01 SW V2 15 Serialnr 12647 Systemname CMC TC PU Il Systemlocation Rittal Herborn Systemcontact Administrator scrolls the display information The values for System name System location and System contact can be entered from the terminal menu or the web browser c closes the menu and retu
9. ice Auf dem St tzelberg D 35745 Herborn Germany Phone 49 0 2772 505 0 http www cmc tc com E mail info rittal de Note Please always specify the item number in the reference line Further information and the current operating instructions for the Rittal CMC TC can be downloaded from the CMC TC homepage 5 17 Scope of Supply 1 x CMC TC Display Unit II 2 x self adhesive Velcro tapes 90 mm x 15 mm 1 x RJ12 interconnecting cable 1 x packaging The following items are also required Accessories Power supply Connection cable for power pack Installation Connection line Control units Designation 24 V IEC power pack 100 230 VAC UL approval 3 A SELV 24 V IEC power pack 48 VDC IEC connector connection cable for Germany IEC connector connection cable for Great Britain IEC connector connection cable for France Belgium IEC connector connection cable for Switzerland IEC connector connection cable for USA Canada FT1 VW1 UL approval IEC connector and socket extension cable 1 U mounting unit 1 U mounting module with strain relief Supply connection cable to the CMC TC system 6 17 Packs of CMC TC Processing Unit Il 1 Required Yes depending on the power supply Yes once for the power pack Optional Optional Yes DK Model no 7320 425 7320 435 7200 210 7200 211 7200 210 7200 213 7200 214 7200 215 7320 440 7320
10. loses the menu and returns to the main menu If no login is performed from the Hyperterminal interface within 60 seconds a switch back to the display will be made If a login is performed on the display unit ensure that a logout is made before the Hyperterminal is closed After the logout an automatic return will be made to the display unit Alternatively a Console timeout can also be entered so that a logout will be performed automatically 16 17 Alarm displays If one or more alarm messages are present they will be displayed on the display as follows displays the individual alarm messages successively Alarm 1 of 3 Temperatur 1 vi2c Alarm 2 of 3 Bewegungsmeld Alarm Alarm 3 of 3 Feuchte v Alarm The maximum number of alarm messages is displayed in the top line The meaning of the icon prefixed to the measured values is the same as that used for the Values display also refer the Values Submenu section If the alarm beeper has been enabled the beeper of the display unit will be activated for each new occurrence of an error c acknowledges the alarm and resets the beeper 17 17
11. menu The following menu items are displayed successively in the main menu switches to the new menu item selects the selected menu item Main menu Values Main menu Network config Main menu System info Main menu IB Te FEST o Main menu Logout display closes the menu and returns to normal operation 11 17 Values submenu This menu item can be used to display the status of all detectors and outputs connected to the processing unit continues with the next detector or output The following information will be displayed for each detector or output Number of the detector unit and connection Name of the detector unit Detector name Measured value or status of the detector or output Unit 1 3 Schrank 1 Temperatur 3 A 38 C Unit 1 2 Server 2 Feuchte A 38 C The following icons prefixed to the measured value have the following meanings Icon A measured value larger than Setpoint high Icon A measured value larger than Setpoint warning Icon v measured value smaller than Setpoint low preselects the associated detector or output for the display in normal operation This is indicated by a dot in front of the measured value Unit 4 2 PC Schrank Spannung e 38 C closes the menu and returns to the main menu 12 17 Network Con
12. n for the installation for commissioning and operation of the Rittal CMC TC Rittal cannot accept liability for personal injury and material damage resulting from non observance of the safety notes in the installation and operating instructions It is essential to observe not only the general safety notes given in this chapter but also the special safety notes given in other chapters Prior to installation the installing technician must ensure himself of the completeness of the supplied components see Scope of Supply page 6 including the required accessories In particular the specified network cables must be used refer to the technical specifications page 7 Working on the Rittal CMC TC Display Unit II The general applicable electrical regulations of the country in which the unit is installed and operated must be observed as also the national regulations for the prevention of accidents and internal rules work operating and safety regulations of the operating company Prior to working on the unit it must be disconnected from the power supply and protected against being switched on again Original accessories and accessories authorised by the manufacturer ensure safety The use of other parts will void the liability for consequences resulting from their use Repair work on the unit may be done only by Rittal or by authorised personnel Operational reliability The operational reliability of the unit is guaranteed only for its inten
13. rns to the main menu 14 17 Untermen Display Setup The following settings for the display unit can be made in this submenu Alarm beeper enable disable This setting enables the internal beeper in the display unit This means an acoustical signal will be sounded should an alarm be issued LED backlight off Alarm on This setting specifies the backlight function Off Switched off in normal operation switched on when the key is pressed Alarm Flashing if an alarm is issued switched on when the key is pressed On Always activated Enable Clear enable disable Releases the e key in an alarm situation i e if the acoustical alarm is active it can be cleared with the key LED brightness 08 This function sets the brightness of the backlighting 0 Background blue text white dark 7 Background blue text white bright Background white text blue dark 15 Background white text blue bright selects the next subitem LJ changes the setting of the selected menu item closes the menu and returns to the main menu 15 17 Logout Display submenu only applies to Processing Unit I Logout display yes no switches between yes and no If the yes setting is confirmed with 4 a logout will be performed and confirmed with the following message logged out c c