Operating instructions Push-button module
Contents
1. Button 2 gang w symbols Ref no 402 TSAP Button 4 gang w symbols f button 1 or 4 Ref no 404 TSAP 14 f button 2 or 3 Ref no 404 TSAP 23 13 3 Planning aids Channel relay station Button programming Example 12 JUNG Light Management Push button module Ref no 4008 TSM 14 Guarantee Our products are under guarantee within the scope of the statutory provisions Please return the unit postage paid to our central service department giving a brief description of the fault ALBRECHT JUNG GMBH amp CO KG Service Center Kupferstr 17 19 D 44532 L nen Service Line 49 23 55 80 65 51 Telefax 49 23 55 80 61 65 E Mail mail vka jung de General equipment Service Line 49 23 55 80 65 55 Telefax 49 23 55 80 62 55 E Mail mail vkm jung de KNX equipment Service Line 49 23 55 80 65 56 Telefax 49 23 55 80 62 55 E Mail mail vkm jung de C The C Sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties 13
2. NG Fig 5 Button configuration for entire surface or top bottom operation for 1 gang 2 gang 3 gang and 4 gang covers Example configurations Figure 5 Entire surface and top bottom operation can be combined on a single device Light Management JUNG Push button module Ref no 4008 TSM 1 gang button Configure for entire surface Press micro button 1 and then 16 Configure top bottom Upper half press micro button 1 and then 4 Lower half press micro button 13 and then 16 2 gang button Configure left hand button for entire surface Press micro button 1 and then 14 Configure right hand button for entire surface Press micro button 3 and then 16 Configure top bottom Left hand button Upper half press micro button 1 and then 2 Lower half press micro button 13 and then 14 etc Activating the grouping mode The grouping mode is activated on the push button module No switching commands are executed in the grouping mode Cover is not installed e Press micro buttons 6 3 5 5 in sequence All LEDs flash 2 x e Press micro buttons 6 3 5 5 in sequence once again All LEDs flash 2 x LEDs 1 to 8 16 flash the grouping mode is active Normal operation after 2 minutes without any button being pressed Assignment of the buttons to the outputs of the relay station Grouping mode is active LEDs of free channels flash LEDs of assigned channels light up continuously A unit
3. comprising a TSM and a TSEM is commissioned via the TSM Assigned buttons are overwritten if they are assigned again e Select channels 1 8 16 of the relay station using micro buttons 1 8 16 The LED of the selected channel lights up All other LEDs are OFF e Press 2 micro buttons of the assigned button Figure 5 LEDs of free channels flash LEDs of assigned channels are ON Repeat the assignment until all desired channels have been assigned Continue with central function or end assignment e Make along press on micro button 16 approx 3 seconds Assignment ended Normal operation JUNG Light Management Push button module Ref no 4008 TSM Central function Grouping mode is active At least one button is not assigned Assigned buttons are overwritten if they are assigned Itis also possible to configure only central ON or central OFF Central ON and central OFF can be configured in any desired sequence e Make a long press on micro button 15 approx 3 seconds LEDs 1 and 2 flash e Press button 1 for central On LED 1 lights up e Press 2 micro buttons of the assigned button LED 1 lights up LED 2 flashes e Press button 2 for central Off LED 2 lights up e Press 2 micro buttons of the assigned button LEDs 1 and 2 light up e Make along press on micro button 16 approx 3 seconds Assignment ended Normal operation T 5 6 ll 7 8 oOo 10 o Jo oe 9 10f11 12 13 14 15 _ 16 OO no
4. push button module within approx 2 minutes All of the red LEDs on both push button modules flash rapidly The button assignment has been applied to the push button module and cloning mode is terminated For further push button modules repeat the steps described above Cloning mode cannot be stopped manually In order to abort a cloning mode process do not actuate any push button module for 2 minutes If cloning mode was activated at the relay station without any connected push button modules cloning mode is terminated automatically after 2 minutes Appendix 13 1 Technical data Power supply via universal relay dimming station DC 24 V Min current TSM approx 3 mA Max current TSM approx 12 mA Min current TSM TSEM approx 3 mA Max current TSM TSEM approx 19 mA Protection level IP 20 Safety class HI Ambient temperature 5 45 C Storage temperature 25 70 C Connection type connection terminal Cable length max 100 m Cable type J Y St 4 2x2x0 8 11 JUNG Light Management Push button module Ref no 4008 TSM 13 2 Accessories Relay station Ref No RS 8 REGHE Dimming station Ref no UDS 4 REGHE Push button extension module Ref no 4094 TSEM Cover kit 1 gang complete Ref no 401 TSA Cover kit 2 gang complete Ref no 402 TSA Cover kit 3 gang complete Ref no 403 TSA Cover kit 4 gang complete Ref no 404 TSA Button 1 gang w symbols Ref no 401 TSAP
5. 00 and Flat Design Supporting ring B side for LS ranges When using the push button extension module Figure 3 Preferred installation vertical Use double supporting ring 13 For installation on only one flush mounted box the lower screws should be countersunk into the wall e g with a 6 x 10 mm hole Use supporting ring as a template DANGER When installing with 230 V devices under a common cover e g socket outlets there is a danger of electric shock in the event of an error An electric shock can be fatal Do not install any 230 V devices in combination with a push button extension module under a common cover e Install supporting ring 1 or 13 in the right orientation on an appliance box Observe the label TOP label A or B forwards Use only the supplied box screws 8 e Plug frame 2 onto the supporting ring e Preferred installation position of push button extension module 11 is below Guide connecting cable 9 between supporting ring and frame bar JUNG Light Management Push button module Ref no 4008 TSM e Push button extension module insert connecting cable 9 in the right orientation in the plug in position 10 in the module Do not pinch the connecting cable e Connect push button module 4 with connecting terminal 7 to the relay station and insert onto the supporting ring e Fasten the push button module s to the supporting ring using the enclosed plastic screws 5 Only tighten th
6. Light Management Stand Okt 12 325 270 03 JUNG Push button module Ref no 4008 TSM Operating instructions Push button module 1 Safety instructions Electrical devices may only be installed and fitted by electrically skilled persons Non compliance with the instructions could cause damage to the device fire or other hazards Connect the push button module exclusively to the universal relay or dimming station no mains potential These instructions are a component part of the product and must remain with the end customer 2 Function 2 1 Intended purpose Push button module for connetion to relay dimming station Installation in appliance box according to DIN 49073 2 2 Product characteristics 8 channels of the relay station can be controlled switching push button control blind shutter 16 channels for relay station connected in parallel in conjunction with the push button extension module 4 channels of the dimming station can be controlled 8 channels for relay station connected in parallel in conjunction with the push button extension module All channels of the relay station are in switching mode in the state as delivered Central function all selected channels of the relay station are controlled centrally Can be configured with 1 gang 2 gang 3 gang or 4 gang cover kit Programming without additional aids Light Management JUNG Push button module Ref no 4008 TSM e Free assignme
7. e plastic screws lightly 5 Commissioning The push button module is ready for operation after it is connected to the universal relay station initial commissioning Push button module Universal relay station Button 1 top Output 1 Button 1 bottom Output 2 Button 2 top Output 3 Button 2 bottom Output 4 Button 3 top Output 5 Button 3 bottom Output 6 etc Push button module Universal dimming station Button 1 top Output 1 dimming up Button 1 bottom Output 2 dimming down Button 2 top Output 3 dimming up Button 2 bottom Output 4 dimming down Button 3 top Output 5 dimming up etc When a push button module is operated with a push button extension on a single relay station the push button extension module does not have any function in the state as delivered JUNG Light Management Push button module Ref no 4008 TSM Fig 4 Button assignment in state as delivered without and with push button extension module Light Management 6 JUNG Push button module Ref no 4008 TSM Grouping The push button module can be operated with 1 gang 2 gang 3 gang and 4 gang cover kits The push button module and the push button extension module have to be grouped depending on the cover and the channels being switched Assignment is performed without the cover Configuring the buttons Each button can be configured for its entire surface or divided top bottom This is done by assigning the buttons as follows
8. nt of the groups to the channels e Red LED as status indicator can be switched off e Blue orientation light can be switched off e Feedback of switching states on all connected push button modules and modules e Upto 4 push button modules with up to 4 push button extension modules can be connected to a single relay station can be used for example in two way or intermediate circuits e Cloning of push button modules transmitting the button assignment of a module to other modules Can be used for example in two way or intermediate circuits push button modules with extension module can be cloned e Easy installation using 2 wire cable e Covers can be labelled using laser labelling tool on the Internet 3 Operation 4 Each button can be operated over its entire surface or top bottom depending on the programming The function depends on the setting of the stations Relay station e Switching push button control press button briefly e Move blind shutter long press on button e Stop blind shutter or adjust slats press button briefly Dimming station e Switching press button briefly e Dimming long press on button Information for electrically skilled persons Installation and electrical connection DANGER Electric shock from touching live parts in the installation environment An electric shock can be fatal Before working on the device disconnect the power and cover live parts in the area Sna
9. o Fig 6 Micro buttons 1 16 7 Changing an existing assignment e Activate grouping mode LEDs of free channels are flashing LEDs of assigned channels are ON When changing the central function make a long press on button 15 e Select new channels 1 8 16 of the relay station using micro buttons 1 8 16 The LED of the selected channel lights up e Press 2 micro buttons of the button being changed Figure 5 e Make along press on micro button 16 approx 3 seconds Assignment ended Normal operation JUNG Light Management Push button module Ref no 4008 TSM 8 Status LED switching on or off The push button module is in normal operation Cover kit is configured e Make along press on button at top or button in a line with the LED for approx 10 seconds Red status LED next to the button is switched on or off 9 Operation LED switching on or off The push button module is in normal operation i e not in programming mode The cover kit is not assembled e Press push button module at the 4 corners for approx 10 seconds 4 micro buttons at the corners 1 4 13 16 are pressed simultaneously Blue operation LED is switched on or off The push button extension module does not have any operation LED 10 Reset Reset push button module to the state as delivered All settings are overwritten The push button module is in normal operation e Press micro buttons 12 9 7 9 in sequence All LED
10. pping on the adapter frame An adapter frame is required depending on the design range LS ranges and Flat Design The adapter frame LS4AR is pre assembled AS 500 and A ranges The adapter frame LS4AR is not required Dismount the adapter frame by means of pressing at the edge of the frame CD 500 JUNG Light Management Push button module Ref no 4008 TSM The adapter frame LS4AR is not required Dismount the adapter frame by means of pressing at the edge of the frame Assemble the adapter frame CD4AR Snap adapter frame CD4AR in the right orientation from the front onto the module 4 Figure 2 Observe the label TOP Connection Caution Connect the push button module exclusively to the universal relay dimming station Fig 1 Connection of push button module TSM and push button extension module TSEM to the universal relay station Fig 2 Installation 1 Supporting ring 2 Frame Light Management JUNG Push button module Ref no 4008 TSM Adapter frame Push button module TSM Locking screw Cover kit Connecting terminal 3 4 5 6 7 8 Box screws F O pa laa Th Fig 3 Installation with extension module 9 Connecting cable 10 Plug in position 11 Push button extension module TSEM 13 Double supporting ring Supporting ring A side for A ranges CD 5
11. s flash 2 x e Press micro buttons 12 9 7 9 in sequence once again All LEDs flash 2 x The state as delivered has been restored Push button module is ready for operation 11 Installing cover kit e The buttons are available as a complete cover kit Individual buttons or the complete cover kit can be replaced using buttons with symbols The assembling web is not necessary to install the buttons e Place buttons on the device in the right orientation and push briefl y to snap in Observe the label TOP Laser print buttons at www jung label de 10 Light Management 12 JUNG Push button module Ref no 4008 TSM Cloning push button modules Cloning means transmitting the button assignment of a push button module to other push button modules No operation of the relay station is possible during an ongoing cloning operation Only pushbutton modules can be cloned from each other Several push button modules are connected to the relay station 13 Press MODE and Central Switching Mode buttons simultaneously until the LEDs Xx ON A and OFF flash The relay station and push button modules are in cloning mode The red LEDs on the push button modules are flashing Press a button on the push button module being cloned within approx 2 minutes The red LEDs on the push button module are flashing rapidly The red LEDs of the other the push button modules continue to flash Press a button on another