1. Figure 12 Settings for the IP input signal format In the Enable line the IP receiver is activated or deactivated In the Port line the data interface is selected A or B and the preferred data interface Is set This function enables the U 124 to switch to the second interface after an input signal has failed and to switch back when the failed signal has been re established prefer A or B If you select the auto option the IP receiver remains on the substitute interface until it is manually switched back or until this interface also fails Under Encapsulation the protocol used in the sender is set RTP UDP IP or UDP IP However the U 124 is also able to detect the protocol automatically and evaluate it accordingly For the Bitrate you can choose between Single PCR SPTS and Multiple PCR MPTS Here the U 124 can also detect the status automatically and process it To have a better overview during the configuration of the HF parameters you have the option of entering an alias If this entry option is not used the first service in the transport stream is auto matically used as the alias Operating Manual U 124 16 programme IP FM converter 8 Configuration of the HF outputs You go to the overview of the HF parameters via the RF submenu in the left frame All 16 output channels with the related data on the data flow are displayed as well as the status of the respec tive FM progra
2. Operating Manual U 124 16 programme IP FM converter In the Stream Selection area the PIDs of the PCR are displayed along with the PIDs of the selected audio stream Figure 15 Stream selection In the Modulation area all the settings relating to the FM output signal are made Modulation m ON MN me MMC m uuu GeckTmeanddse eene Be ucPSewee1 Torena Figure 16 Setting the PAL modulator RF line Activating and deactivating the output signal Standby output signal selected and configured by HF switched off Selecting the output frequency Setting the output level Setting the audio hub Line Radio data system Activating the RDS Line Program If the data are available in TS and if the option dynamic off Service name is selected the PS data will also be transmitted If static is selected you have the option of entering 8 blocks of 8 characters and determining the time interval min 3 s For a static configu ration but a PS is in the TS the TS data are processed with priority Line Programme e f the Pl is transmitted on the sender side then the setting dyna identification mic will result in transmission on the output side If static is con figured a sender ID is entered then this setting is transmitted until there is a Pl on the input side Line Programme type Transmission of the programme type ID pop news etc In this case the
3. nt AE p EEE i abes Ka Lenk id erp i HE HH Inu Figure 3 Connecting the voltage supply and signal lines The backplane is now carefully inserted into the free slot of the U 100 base device and screwed in with the Phillips screws of the backplane Here you must ensure that the cables are not jammed and that the backplane can be installed in the housing with only a small amount of pressure Figure 4 Correctly installed backplane Operating Manual U 124 16 programme IP FM converter 3 General introduction 3 1 Connecting the U 124 to a PC laptop When the operating voltage is connected or after it is inserted into the slot of the base device the U 124 switches on automatically After the boot phase ca 90 seconds the two management IP addresses appear in the display along with other status messages If the device is connected to a PC laptop via one of the network ports and if the PC laptop is suitably configured via the network settings after you enter the IP address in the address line of the Web browser you can start configuring the U 124 3 2 The Web browser user interface The Web browser user interface is divided into the top frame the left frame and the main frame The top frame contains general information about the U 124 Figure 1 General information in the top frame of the Web browser user interface This information is as follows SW 4021 indicates the software level of the U 124 Ed
4. Operating instructions MR o ASTRO EdgeFM U124 i cose ee NG MgmA 192 168 1 221 A RF1 1 Channel Settings e uiam Sy Time 25 Oct 2010 10 51 48 UTC Up 0d 02h 36m 475 ASTRO EdgeFM U124 SW 4021 FW 1 2 HW 1 MTS LH Name ASTRO EdgeFM U124 Location Headend City Contact kontaktibastro kom de user is logged in Status Service Selection Logout Man IP RX Transport Stream Service HIT RADIO FFH MEDIA BROADCAST SD 12660 Digital radio Submit Resel Stream Selection Imm Service IP RX3 TSID 1113 ONID 1 Alias K TV MEDIA BROADCAST 12660 0 for manual PID selection MgmA 192 168 1 221 pynt 192 168 5 221 Submit Reset Time 25 Oct 2010 010 10 84 48 UTG Up 0d 02h 36m 47s ASTRO EdgeFM U124 SW 4021 FW 12 HW Name AS kontakt astro kom de TRO EdgeFM U124 Location Headend City Contact Modulation Ethernet bandwidth Propari Management A ath0 1G Management B eth 1G Data A eth 16 Data 8 jeth3 1G Data A eth 10 Data B fetnd 10 NPE Perr Seo EI LA LA EL SR L E 3 adig 496 p MUL PR 70 3 ms 1825 bytes 262 Frames 3 7 packets 13263 MO 51 2 none 14416950 0 o 0 0 RTP UDP IP 207 8 ms none 5058505 0 0 0 0 de ASTRO Strobel Kommunikationssysteme GmbH U 124 16 programme IP FM converter U 100 Base unit General Note concerning the U 100 230 base unit This equipment has been tested and found to comply with the limits
5. error Displays indicate the status of the device operation as well as the existence of DC voltages separate from the mains that are supplying the components of the device However operation displays that are not lit up in no way indicate that the device is completely disconnected from the mains or is voltage free Read carefully EN 60 728 Part 11 Safety requirements No service tasks during electrical storms 2 3 Assembly instructions The U 100 base device may only be mounted using guide rails If the device is only fastened by means of the screws in the front panel this will damage the base device The outputs of the signal converter must not be operated without connecting a combining network or terminating impedance Protection from environmental factors The device must only be connected and operated in dry rooms It must not be exposed to spray ing or dripping water or to similar phenomena If condensation appears wait until the device is completely dry Objects containing liquid must not be placed on top of the device The permitted ambient temperature range is 0 45 C ETS 300 019 1 3 class 3 1 Mounting environment The device is designed for operation in preferably metallically conductive 19 racks with suffi cient air convection It should be operated away from heat radiation and other heat sources The device my only be installed in rooms in which the permitted ambient temperature can be adhered to even
6. Forward msg to pipe Tftpd32Syslog Save syslog messages To file Tftp Server Log viewer DHCP Server start time progress Tm t TFTP Security TFTP configuration None Timeout seconds Standard Max Retransmit About Settings Help i C High Tftp port C Read Only local ports pool Advanced TFTP Options v Option negotiation PXE Compatibility v Show Progress bar Iv Translate Unix file names Bind TFTP to this address Hide Window at startup Create dir t t files Create md5 files Beep for long transfer Allow As virtual root Use anticipation window of o Bytes Default Help Cancel Figure 22 Settings for the tftpd32 TFTP programme To start the update the IP address of the local computer must be entered as the server address in the line T F TP Server address Figure 23 and the protocol set to TFTP Thus it is no longer necessary to enter a user name and a password In the File line you now select the option Update and press the Submit button to start the update NOTE A reboot or a network failure during an update process can cause the U 124 software to crash irrevocably The device then has to be returned to ASTRO for repair Operating Manual U 124 16 programme IP FM converter 13 System log Clicking on the System Log submenu takes you to the log of the U 124 All the procedures rel evant to the operation
7. PTY in the TS will be transmitted with priority over the manually configured PTY Operating Manual U 124 16 programme IP FM converter Line Traffic Programme ident Line Music speech Switch Line Radio text Line Clock time and date Operating Manual U 124 16 programme IP FM converter v Activates the transmission of the traffic radio ID A Transmits the ID if provided by the sender whether music or speech is being transmitted Accordingly some end devices can automatically adjust the tone control Transmits if provided by the sender the radio text If static is configured and a text entered this will be transmitted until radio text is dynamically transmitted by the sender If this option is activated then the display of the current time will appear in the receiver The radio service in TS or the IP RX can be used as the synchronisation source source If both sources are configured the TS is evaluated first and then the IP RX 9 User administration You reach the user management by clicking on the User submenu The U 124 allows you to create four different users In the state on delivery admin user and bc4 are created all with the password astro Note For security reasons the user names and passwords should be changed from the state on deliv ery This prevents unauthorized access In the Timeout line the minutes are en
8. Strobel Kommunikationssysteme GmbH Figure 25 Example view of the network properties in the Network Monitor submenu Operating Manual U 124 16 programme IP FM converter 16 Logout Clicking on the Logout submenu only available when you are logged in takes you to the logout of the U 124 User Logout Are you sure Yes Figure 26 Logging out of the U 124 If you confirm the request by clicking Yes you are logged out No further settings can be made without logging in again but you do have the option to view the settings of the U 124 However the setting elements are inactive Operating Manual U 124 16 programme IP FM converter 17 Technical data AST U 100 48 U 100 230 Order number 380 100 380 101 Network interfaces forwarded passively to U 1xx Management 2 x 100 Base T Ethernet RJ 45 Data 2 x 1000 Base T Ethernet RJ 45 Protocol IEEE802 3 Ethernet RTP ARP IPv4 TCP UDP HTTP SNTP IGMPv3 Transport stream processing TS capsulation UDP UDP RTP 1 7 packets FEC Transport stream processing transparent 188 or 204 packets Control and management Properties Control via HTTP WEB Protocol HTTP SNMP error messages General data Input voltage V 48V DC 100 230 V AC Power consumption W depends on equipment Housing 193 HE Permitted ambient temperature C 0 45 Order number 380 124
9. UDP port that will be matched for this channel User For an IP multicast use an address in the range 225 0 0 0 to 239 255 255 255 fs Analyzer Use 0 0 0 0 to disable Source Select or Secondary Receive IP icensing Update System Log Meran ASTRO Strobel Kommunikationssysteme GmbH controller Figure 10 Detailed settings of the IP receiver To enable the greatest possible path redundancy the U 124 has various different configuration options for the IP receivers The Data A and Data B ports can be configured completely indepen dently of one another IGMPv3 enables what is known as Source Select i e the IP receiver can request the data from a preferred source Operating Manual U 124 16 programme IP FM converter Data A eth2 1G Data B eth3 1G 10000 232 100 131 m Figure 11 Setting the Multicast addresses The use selection box defines the data source used This data source is defined via the Multicast address and can if this Multicast address is provided by multiple senders be used preferentially by the IP receiver The IP address of the preferred source is entered under Primary Secondary Source Select If 0 0 0 0 is displayed here the Source Select function is deactivated If different signal paths are supplied by the same sending equipment it can make sense to con figure Data B exactly like Data A This is easily performed by activating like Data A Data A oth Data 6 001
10. alternative config Default Load factory default settings Reboot Force reboot The Default button is used to restore the factory settings Note With the factory settings all the settings apart from the user and network settings of the data and management ports are reset to the state on delivery The Reboot button restarts the U 124 with the last settings that were entered Operating Manual U 124 16 programme IP FM converter AS Configuration of the IP inputs ASTRO When you click on the IP RX submenu in the left frame the following window appears example An a Status Logout Main RF1 1 RF1 2 RF1 3 RF1 4 RF1 5 RF1 6 RF1 7 RF1 8 RF2 1 RF2 2 RF2 3 RF2 4 RF2 5 ASTRO Strobel Kommunikationssysteme GmbH RF2 6 RF2 7 RF2 8 User TS Analyzer Licensing Figure 9 Overview of the IP input configuration Here the four IP inputs to be configured are activated or deactivated and their current configura tion is displayed You go to the detailed settings either by clicking the relevant channel e g IP RX3 or clicking the relevant submenu in the left frame Gro RD ge IP RX1 Channel Settings Main Data A etn2 1G Data B eth3 16 IP RX ll Fr o fo fo To MEN oo fo To To To fo 1 o fo jo jo REST o o o o p To D T NEN RF1 3 Data A eth2 Data B eth3 RF1 4 RF1 6 RF1 8 RF2 1 RF2 2 RF2 3 RF24 RF2 5 RF2 6 RF2 7 RF2 8 Enter the IP address and
11. device 2 1 Description of functions The U 100 series is used to convert IP data streams into CATV signals The U 100 230 base device can accommodate up to three U 1xx signal converters as well as up to two U 100 SNTs for supplying the voltage to the U 1xx signal converters The U 124 receives up to four video data streams encapsulated according to the internet protocol IP and converts them into up to 16 standardised FM output signals 2 2 Safety instructions Disconnect both mains plugs before opening the device The device must not be opened for exceptions see the maintenance and repair and the service tasks Power supply units must not be opened The device must be connected to a power supply with an earth contact and should be positioned close to the mains socket The electrical system supplying current to the device e g a house installation must incorporate safety devices against excessive current short circuiting and earth leakages in accordance with EN 60950 1 Both mains plugs are used to disconnect the device from the mains therefore they must be easy to access and use at all times The device is already in operation when one power unit is connected to the operating voltage When the second power unit is also put into operation one of the power units runs in idle mode as long as the other unit is supplying power to the device The device may only be repaired by sending it to ASTRO along with a precise description of the
12. for a Class A digital device pursu ant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Changes or modifications of the device not expressly approved by ASTRO Strobel Kommuni kationssysteme GmbH or any licensed party responsible for compliance will void the user s authority to operate the equipment This operating manual was created to provide the relevant instructions for operating the U114 We expressly recommend reading this manual before installing or operating the device The ASTRO company confirms the information in this manual to be correct at the time of printing but it reserves the right to make changes without prior notice to the specifications the operation of the device and the operating manual The ASTRO company is not responsible for printing errors The contents of this operating manual are confidential and protected by copyright This manual may not be reproduced in any form not even in part without prior written permi
13. of the device are documented here Additionally the SNMP settings are made here defining the trap recipients the trap community amp the trap filter Also the Log file filter line can be used to define which events lead to an entry in the log System Log Settings ESTE 0000 0000 0000 sur eee m RF11 RF12 RF1 3 RF1 4 RF1 5 RF16 RF1 7 SNMP MIBs RF2 1 SEEN AstoStrobelmib EEE AstroStrobel EdgePAL mib RF2 4 Note Use 0 0 0 0 for unused or unknown SNMP addresses RF2 5 System Log RF2 6 RF2 7 Refr P RFI 8 esh Check box to clear log on refresh User System log in CSV format log csv Use right click and save as to save locally TS Analyzer Licensing IP configuration in XML format ip xm Update System settings in XML format settings xmi System measurements in XML format measure xmi Statistics System status in XML format status xml Network Module info in XML format module xml Channel list in XML format chlist xmi user Use right click and save as to save locally on is logged in number time uptime user source severity message 1 25 Oct 2010 09 53 36 UTC 0d 00h 27m 49s user 192 168 1 40 infc SNMP changed Timeout in 2 25 Oct 2010 09 45 01 UIC 0d 00h 19m 145 user 192 168 1 40 info Login 3 25 Oct 2010 09 37 06 UTC 0d 00h lim 19s user 192 168 1 40 info Logout 4 25 Oct 2010 09 36 49 UTC Od 00h lim 02s user 192 168 1 40 info TV Service 4 changed 5 25 Oct 2010 09 36 48 UTC Od 00h lim 01s system loca
14. sov internal voltages Fan 0245 RPM er and the power unit Power onde 2 status System memor Tota s r Of memocy arene 44549584 Hume of orden memory boctes t Space used by ontnany memory blocks 257102 Space tree hor ortinary Bloc Ses of Inigest tree block ASTRO Strobe Kommuntumons s steme Cete 43792172 83787516 Here all the relevant dataforthe status ofthe U 124 is displayed in detail No settings can be made here Memory status Figure 3 Status display in the Status submenu Operating Manual U 124 16 programme IP FM converter An ASTE 6 Settings for the IP interfaces IP management and base device When you click on the Main submenu in the left frame the following window appears example Status Logout IP RX RF User TS Analyzer Licensing Update System Log Statistics Network controller on Is logged in Timeout in S IP interface Settings Property Management A eth0 Management B eth1 Data A eth2 Data B eth3 EN BARAA psp p ps T ps EN D TT Js oss Joss Jo Js psp T JPP T Bi Pics Ti Teo fo fo T III III fo fo Note Please use different IP address settings for each interface IP Management Settings DNS 192 we 1 100 0000 Time source SNTP Server Note Use 0 0 0 0 for unused or unknown DNS or SNTP addresses U100 Rack Settings Save settings to flash Load settings from flash Default settings Reboot system
15. under changing climatic conditions To avoid trapped heat it must be freely ventilated on all sides You absolutely must avoid mounting the device in a niche or covering the ventilation openings Operating Manual U 124 16 programme IP FM converter 2 4 Potential equalisation earthing The subscriber network must be earthed correctly in accordance with EN 50083 1 and must remain earthed even when the device is removed The potential equalisation on the U 100 is effected via the fastening plates of the device or via the earthing connection on the back of the device Devices within hand s reached must be incorporated into the potential equalisation among one another It is not permitted to operate the device without an earth conductor device earthing or device potential equalisation 2 5 Maintenance and repair Disconnect both mains plugs before opening the device The device must not be opened other than for repair purposes In general power units must not be opened Repairs may only be carried out at the plant or at workshops or by persons authorised by ASTRO Strobel Kommunikationssysteme GmbH Read carefully DIN VDE 0701 0702 Repairs Note The device must not be opened by the user 2 6 Service tasks The following tasks in which screw connections have to be opened can be performed by appro priately instructed service personnel Removal and installation of signal converter
16. 1 12 2011 Operating Manual U 124 16 programme IP FM converter
17. 2 19 100 191 100000000 000000000 1328 tyes LCoS pg AU packets OR 20 52777 MD 199214 KTO Gobelant 19 398 1 10 PUPWAY 232 19 100 131 100000000 000022200 R P ma PCR 7797 RF Channels Pi 62304 PTY 18900 8 PUT 50 son MOR SPUTI ARD MOR PCR 561 87 500000 Vtt EUM al To oO pg 902049 581 10008 a 320 9 Layer 2 48 99 AT MOR BFUTMIK Bustset que sento Mi cr Pe PUT 540 REL2 TSO 1093 OND I JUMP ARD MOR PCR 541 88 000000 Mee WT Anruf wa JUMP Brute unter 0800 18 Ama Saren ARD BR 20 28432 Auto 541 1008 ET 220 its Layer 2 45 10 Stereo m asac P axi bad p DR sen amp r12 TSO 1095 ONO I MOR FIGARO ARD MOR PCR 431 55 500000 Mz M Mune Aun Basam ARD BR 90 2943 Audo 31 1008 329 an Layer 2 4599 Stereo ET WOR AGANO Dee Katta Matic or PUT 830 ar 18590 8 sets Tap oup JOY ARD NOR PCR 631 89 000009 un 200 08 P nor Ass Bayern 1 ARD BR SD Ao 63 1008 NT BOT FOM NOR www pop ite 220 beets Layer 2 AB p Stereo ct vm WOR 3 ARD WOR RR M 80 500006 A 1121 we AR Ma Beam Y ARD an 902147 AUS 1121 100 og AT WDP 1 Missa Forum 320 HES Layer 2 48 9Q Stereo m PUT 11 BELE T O 93 0801 WOR 2 ARD WOR POR ttt 90 000000 Mz PTF em Anas Bayer 1 ARD BR FO 29478 Auto tn 1008 AT Die VOR 1 oimne 022 96799 222 obs Layer 2 PE Slereo PUT 1060 TSO 1093 080 1 vm AR e ve WT a Av da are Mesna Mar BE n berem ARD BR 02847 Murdo 108 1008 e ren 220 Mos Layer 2 48 ee Stereo wm SWR 3 ARD SWR 9 020005 Use me 18 20088 BEL
18. E TS 1093 OMD Ans Bayern ARD BA 24358 Aun 103 1000cB AT SWRO Nacmecmen dm 12 Un eat ie St t di f 320 bs Layer 2 48 ee Stereo er 1UVE ARD FOR 1101 we pre O Papas EM S ay 9 101 a2 TSO 93 OND eA pr 3 eye RT Devi Guetta fest Met Cum ma Mem t e Out ut stan Bayern 1 ARD BR 520 vits Layer 2 ab eee Stereo er p PUT 1110 0822 FAM soup WOR2 ARD Won PCR 11 2 PTY 16 Pop M programme Ann Bayern I anp Ba 9929475 1000 MT Der WOS 2 Hotere 022 679 222 Mots Layer 2 Ab iiz Stereo wn WOR 3 ARD won PER A EN 1121 92 500002 Mee 8 21 TROND 902947 fade 10M 0008 ar WOM I riasatb Porum 220 kits Layer 2 48 ka Stereo A WDR 4 ARD WOR XI 93 000909 Lee t ee MOOR auaa 1121 106 dB CT momet cum wEMLAD 220 kits Layer 2 48 c Stereo 0035 un PUT 1140 gt WOR 8 ARD WOR PCR 1141 C we GELS Me Deom A ARD gn 9929479 Aug 1141 106 o8 Tr WOP 9 tar Voruenker ung Nachden 220 zus Layer 2 46002 Stereo RERS ce cums PCR VIG 94 000202 Me MET dn SOR Aa 8t 100 dB 296 ius Layer 2 48 ke Stereo Pur ao TUR PCA 110 4 em zl TED 1070 oup SD 2902 Mudo 710 1008 254 kt Layer 2 AS ee Stereo aine MNUKA ARO WOR PERAI 95 000000 1171 um A on OIN Mudo 1971 1008 Tnm m 329 ibd Layer 2 d wc Stereo Terpersture cente 38 5 C Tempecamwe 2 ront 450 C Temperatur J ires 825 C Tenpecamum 4 PA 215 C UI ite Display of diverse mV rmv status messages fan on the module Supply 33V 129v spys Bav temperature the spy av
19. Network interfaces forwarded passively to U 1xx Management 2 x 100 Base T Ethernet RJ 45 Data 2 x 1000 Base T Ethernet RJ 45 Protocol IEEE802 3 Ethernet RTP ARP IPv4 TCP UDP HTTP SNTP IGMPv3 Transport stream processing TS capsulation UDP UDP RTP 1 7 packets FEC Transport stream processing transparent 188 or 204 packets Audio decoding MPEG 1 Layer 2 Stereo FM modulator Output frequency MHz 87 5 108 Step size kHz 10 RDS data UECP ancillary data sep PID static PS 2 x 8 characters dynamic Pi Radiotext PTY PS CT MS Output level dBuV 114 Intermodulation interval dBc 70 Reflexion loss dB gt 14 Signal to noise voltage ratio dB gt 65 External voltage ratio dB gt 72 Pre emphasis us 50 Stereo crosstalk attenuation dB 60 Distortion factor 26 0 05 Frequency response dB General data Power consumption W 30 Housing 19 1 HE Permitted ambient temperature C 0 45 Operating Manual U 124 16 programme IP FM converter Operating Manual U 124 16 programme IP FM converter Operating Manual U 124 16 programme IP FM converter Fr ages ASTRO Strobel Kommunikationssysteme GmbH Olefant 1 3 D 51427 Bergisch Gladbach Bensberg Tel 02204 405 0 Fax 02204 405 10 eMail kontakt astro kom de www astro kom de 82251 40
20. Save 2nd All settings are saved to an alternative config Load 2nd All settings are loaded from an alternative config Default Load factory default settings Reboot Force reboot Figure 4 Overall view The settings available are described in detail in the following sections Operating Manual U 124 16 programme IP FM converter 6 1 Configuration of the IP interfaces In the area of the user interface displayed below you can activate and deactivate the IP interfaces The connection type is automatically detected and displayed by the U 124 Here 1 GBit s full duplex for Data A and 100 MBit s full duplex for Management A I 2 Property Management A eth0 Management B eth1 Data A eth2 Data B eth3 El 3 F A had La cn Cn Pal eg cn en CTI f 71 g x ra 71 aa La La Note Please use different IP address settings for each interface Figure 5 IP interface configuration Changes to the IP addresses must be transferred to the U 124 using the Submit button Note When programming the IP addresses make sure the addresses are not already allocated in your network Address conflicts lead to malfunctions in the network 6 2 IP management configuration In the IP management configuration the DNS server and the SNTP server are entered If a valid entry is made under SNTP server this can be used as a time reference The MPEG flows TDT are additional time refe
21. g just your firewall to allow T F TP traffic any transfer is started System Log Statistics Network user n is logged in Timeout in S Figure 20 Action selection in the Software Upgrade submenu Here you have the option to store the configuration of the U 124 on an FTP server Clicking on the Update submenu takes you to the settings for the U 124 software update In the T FTP Server address line you enter the T FTP server address at which the current software for the U 124 is stored In the Protocol line you can choose between FTP File Transfer Protocol and TFTP Trivial File Transfer Protocol If you choose the TFTP option it is not necessary to enter the user name and the password Under Path you must enter the path under which the U 124 software for the update was stored You must ensure that the software is stored in the path entered with at the start and the end otherwise no update is performed You must also ensure that any firewall installed allows T FTP communication The Update submenu also provides the option to save the configuration of the U 124 on an FTP server or to load a configuration into the U 124 Loading a configuration into the U 124 does not affect the settings of the IP interfaces 13 1 Update using example of a TFTP server for Windows If no fixed T FTP server is set up for updating the U 124 you also have the option to transfer locall
22. gePAL FW 1 2 is the level of the firmware in the U 124 EdgePAL HW 1 is the hardware version of the U 124 EdgePAL Up Od 2h 36m 12s is the duration of the connection measured from the moment of the login Time UTC displays the time of the U 124 The line in bold for the name location and contact is made up of the settings in the User chapter In the right section of the top frame status information for the U 124 is displayed i e in the Web browser user interface the latest error message is visible Figure 2 View of U 124 Display of the Web browser user interface The left frame contains the navigation bar for the various submenus which are described in detail in the follow ing chapters In the main frame the submenu is displayed according to the selection made in the navigation bar in the left frame Operating Manual U 124 16 programme IP FM converter 4 Login Before the U 124 can be configured there must be a login This is performed in the Login sub menu In the state on delivery the login data is as follows User admin or user Password astro After correctly entering the login data you can proceed with the configuration Note For security reasons the user names and passwords should be changed from the state on deliv ery This prevents unauthorized access Only one user U 100 C can ever be logged into the U 124 At the very bottom of the left frame of the Web browser user in
23. ics Network user on is logged in Timeout in S Figure 19 Input mask for licence key To order additional licences you must enter the MAC address of the device You will find the MAC address on the Web browser interface in the Licensing submenu HWID After the MAC address is passed on the licence keys are generated at the ASTRO company and issued by e mail or on a CD The format of a licence key is a text document e g Lic001772000222 txt You can use copy paste to copy the key s into the input mask and press the Submit button to transfer the licences to the U 124 If the licence is valid this is confirmed with the message License is valid An error message is displayed for an invalid licence Operating Manual U 124 16 programme IP FM converter 12 Software update saving and loading a configuration When you click on the Update submenu in the left frame the following window appears example Status Logout Software Update Main IP RX1 gt RE Please select RF1 4 RF1 5 RF1 6 RF1 7 RF18 Load config from server RF2 1 For a quick start you may want to 1 Save config to server RF22 Username and password are only Update firmware from server RF2 3 Please consider that the given pat Update firmware from SD Card RF2 4 Overwrite backup firmware RF2 5 Note Load config excludes IP Interface Settings RF2 6 RF2 7 Reset zx User ASTRO Strobel Kommunikationssysteme GmbH TS Analyzer Licensin
24. ignal converter and the base device Both the mains HF connections and the network connections are connected to this backplane The temperature controlled fan for cooling the U 1xx signal converter is located on the backplane 2 8 1 Coding the backplane To correctly define the position of the backplane and thus the position of the related signal con verter in the U 100 base device the jumper on the board of the backplane which is described in the following section must be configured T NAA COE 7 ow iQy moony tenra ab MO MOY 14 07A d x Left i Right ym Ml 3000000 Jumper position No jumper Jumper position left right Figure 1 Coding the backplane using the jumper Note An incorrectly configured jumper leads to incorrect displays in the front LEDs EJ Additionally it is not possible to display a correct position on the Web user interface Operating Manual U 124 16 programme IP FM converter 2 8 2 Installing the backplane In its state on delivery the back of the U 100 base device is covered with blind panels Phillips screws Figure 2 Position of the blind panel on delivery of U 100 To remove the blind panel unscrew the two Phillips screws indicated in the above figure and remove the blind panel The cables now visible must be connected to the backplane coded according to chapter 2 8 1 as shown in the following figure PT TT R ASTRO EdgePAL U114 ASTRO RF1 1 Channel Betnegs
25. l notice Decoder 4 ok 6 25 Oct 2010 09 36 45 UTC Od 00h 10m 58s user 192 168 1 40 info TV Service 4 changed 7 25 Oct 2010 09 36 02 UTC Od 00h 10m 15s system local error Decoder 4 no ttx data 8 25 Oct 2010 09 35 58 UTC Od 00h 10m 118 system local notice Decoder 4 ok 9 25 Oct 2010 09 35 54 UIC Od 00h 10m 07s user 192 168 1 40 info TV Service 4 changed 10 25 Oct 2010 09 35 23 UIC 0d 00h 09m 365 system local error Decoder 4 service not present 11 25 Oct 2010 09 35 22 UTC 0d 00h 09m 35s system local error IF RX4 got flushed 12 25 Oct 2010 09 35 21 UTC 0d 00h 09m 345 user 192 168 1 40 info IP RX B 4 changed 13 25 Oct 2010 09 35 21 UTC 0d 00h 09m 34s user 192 168 1 40 info IP RX A 4 changed 14 25 Oct 2010 09 32 48 UTC 0d 90h 07m Ols system local notice Decoder 4 ok 15 25 Oct 2010 09 32 45 UTC 0d 00h 06m 58s system local error Decoder 4 no video data 1 amp 25 fter 9010 00 32 40 TITS N Anh N m 53a naer 102 168 1 An infa TY Servire rhanned Figure 23 System log settings The SNMP MIBs available are stored on the U 124 and can be downloaded from the device The operations in the system log are sorted by the time they occurred To delete the log file you set the flag for Check box to clear log on refresh then click on the Refresh button The first entry in the log is then the deletion operation together with the time and the user account as well as the IP address of the user NOTE e Downloading the IP configuration via the
26. link ip xml e System settings via the link settings xml e System entries via the link status xml Module information via the link module xml Operating Manual U 124 16 programme IP FM converter P ASTB 14 Statistics Clicking on the Statistics submenu takes you to the statistics for the data transfer of the U 124 Here all the statistics relevant to the operation of the device and its analysis are displayed Status Logout Ethernet bandwidth Property Management A eth0 1G Management B eth2 1G Data A eth2 1G Data B eth3 1G Main IPRX Ethernet frames Property Data A eth2 1G Data B eth3 1G RF1 1 RF1 2 RF1 3 RF1 4 RF1 5 RF1 6 RF1 7 RF1 8 RF2 1 RF2 2 RF2 3 RF2 4 RF2 5 RF2 6 RF2 7 RF2 8 User TS Analyzer Licensing Update System Log Network Ethernet RX user on is logged in Timeout in ASTRO Strobel Kommunikationssysteme GmbH Figure 24 Statistics for the data transfer Operating Manual U 124 16 programme IP FM converter 15 Network properties AST You reach the network properties by clicking the Network Monitor submenu The properties displayed are purely for information purposes and are used to describe the network Status Logout Logical Interfaces Main IP RX IP RX1 IP RX2 IP RX3 IP RX4 RF2 6 RF2 7 RF2 8 User Protocols TS Analyzer Licensing Update System Log Statistics user on is logged in Timeout in S ASTRO
27. lt and reboot 14 Configuration of the IP inputs elsssssessessseseene nennen nennen nennen nnne nnns 15 Configuration of the HF outputs uusssnnensnnnessnnnnannnnnnnnnnnnnnnnnnnnnnnnnnnonnnnnnnnnnnnnnnnnnnnnnenn 17 VEFAS AL ON NT E TE ae m 20 Transport stream TS analyzet n een 21 Se geo EE EE RE EE EE 22 Software update saving and loading a configuration rrrnrerrnnnrrrnanrrrrnrnerrnanrennannennnnne 23 12 1 Update using a TFTP server for Windows as an example 24 veh SUS 016 EEE EIE PT 25 UNS P MR 26 Network PIODENIGS sinne nennen engere 27 LOGO een Tm 28 TS GHC Alaa EE Um 29 AST 1 Figures The figures show the U 124 installed in the U 100 base device Control and data wheel menu switch Display of management IP addresses data IP addresses status messages etc Status display 230 V power supply unit m AF isn p fear fet F l Mains supply Earthing connection Mains supply Management ports 48 V power supply unit ESSERE c wre es F oi Mains supply Earthing connection Status display for slots L left M middle R right P power supply Data ports HF outputs Fan Operating Manual U 124 16 programme IP FM converter 2 Introduction The instructions in chapter 2 mainly apply to the U 100 230 base
28. lysis of the EIT Event Information Table can take somewhat longer A data stream can be received with CBR Constant Bit Ratio in the U 124 or with VBR Variable Bit Ratio In any case CBR is used in MPTS Multiple Program Transport Stream but also in SPTS Single Program Transport Stream However SPTS can also be sent with VBR Under Packet Mode you can choose between continuous or burst for the configuration of the respective ASI outputs after the IP RX The TSID and ONID are displayed according to the transport stream selected and an alias can be entered for a better overview of the transport streams see also Figure 11 If no alias is entered the name of the first service of the transport stream appears Operating Manual U 124 16 programme IP FM converter EB ASTE 11 Licencing Some functions of the U 124 e g the TS Analyzer must be activated using a licence key The licence key can be obtained from ASTRO along with the function The text sent is then copied into the text input field and transferred to the device using Submit Status Ww Logout Licensing Main IP RX This device has the HWID 00 17 72 02 01 05 and you have already licensed 0 IP TX IP RX1 IP RX2 pus IP RX3 and a RF11 ASTRO Strobel Kommunikationssysteme GmbH RF1 2 RF1 3 RF1 4 RF1 5 RF1 6 RF1 7 RF1 8 RF2 1 RF2 2 RF2 3 RF2 4 RF2 5 RF2 6 RF2 7 RF2 8 User TS Analyzer Update System Log Statist
29. m Here the output channel can be activated or deactivated If you select Standby here only the HF is deactivated However the configuration of the output signal remains active along with the analysis of the input data flow Changes must be written to the device by pressing the Submit button llr 2 pen s RF Channels Modulator Faad re a Roun g t Is Em je 5 i n B gt i x i P Figure 13 Overview of the HF parameters If you select the option On in the Reference column then the level set in the modulation parameters will be used as the reference value A deviation of 2 5 dB leads to a warning mes sage a deviation of 3 dB leads to the output channel being switched off You go to the detailed settings either by clicking the relevant channel e g RF 1 1 or clicking the relevant submenu in the left frame In the detailed view of a channel the programme to be converted into FM is selected under Input Selection This programme can be applied from any of the four IP receivers Wen ar i ind T on 7 Li IL EL MIL UE WIR I i D Du re re lus ul DTI LE Far TV 12660 L Pu 4 de i ee EE e Fu M Property NTE 4 9 UE I dcr E Mi A ENG i finais gs nina ge LI LI 4 li T a 11 i VE nn ME Figure 14 Output channel setting
30. me Olefant 1 3 D 51427 Bergisch Gladbach Germany Tel 49 2204 405 0 All other parts of the software of this product are copyrighted by Astro Strobel Kommunikationssysteme GmbH Operating Manual U 124 16 programme IP FM converter Table of contents 10 11 12 13 14 15 16 17 Operating Manual U 124 16 programme IP FM converter FU 4 Fa lg 010 ETEei o EE T an ee SN NE 5 2 1 WSSCMOUOM OF TMM CONS ve kap 5 2 2 Galely NSTUC ONS nissen nen ee eher een 9 2 3 ASSEmMDIy INSIrUCHONS sanieren 5 2 4 Potential equalisation earthing us020040000Rennnnnnnnnnnnnnnnennnnnnnnnnnnnnnennnne nennen 6 2 5 NAH IENANCES 1 G 9 EEE NPE 6 20 2 2 ee 6 2 7 Technical data for mains SUDDIV nenne een 6 2 8 Installing and coding the backplane u een 7 2 81 Coding the backplane 2 ein nen 7 2 82 Installing the backplane rrannnrrnrnnnnrrrrnnnnrvnrnnnnrrnrnnnnrennnnnnnrennnnnnsnnnnnnsennnnnsnsene 8 General introduction iene seis cere E 9 3 1 Connecting the U 124 to a PC laptop 2uuusssnnennnnneennnnnnnnnnnnnnnnnnnnnennnnnnnnnnn nennen 9 3 2 Ihe Web browser user Interface ae 9 Sorel Emm 10 ELE ERE EET 11 Setting the IP interfaces IP management and base device 12 61 Configuration Of the IP interfaces orate m ee 13 6 2 IP management configuration anna 13 5 3 U LUE IDEE 14 6 4 Saving and loading a configuration defau
31. port stream is analysed Status TS Analyzer Logout Main IP RX KTO Eins 95at TELE are ciob Extr 2pFv Beta IP RX2 t ARD S10 Digi IP RX3 n tal RF ONID 1 8468 Pe EN E BEE RX1 RX2 RX3 RX4 Gen Ana RF1 4 lyze RF1 5 RF1 6 RF1 8 RF2 1 RF2 2 RF1 1 RF1 2 RF1 3 Please be patent unt measurements are finished e g EIT may take a long time User Licensing Update saeara Gas Analyzing i Tables t G PAT PID 0 TSID 65535 version 0 valid current SDT actual PID 17 TSID 65535 ONID 65535 version 0 valid current CJ SID 0 NID PID 16 user SID 1 PMT PID 100 ds PMT PID 100 SID 1 PCR PID 101 version 0 valid current aem GIES PID 101 ISO IEC 11172 Audio Timeout in s O Audio stream id Layer II O 180 639 language ZXX clean effects U Stream identifier 1 3 SDT Status running Free EIT present following U Service name ASTRO provider ASTRO type Digital radio sound CJ CAT PID 1 version O valid current 3 NIT actual PID 16 NID 65535 version 0 valid current C TDT PID 20 UTC 25 Oct 2010 09 50 17 done ASTRO Strobel Kommunikationssysteme GmbH Figure 18 Transport Stream TS Analyzer view The optionally available TS Analyzer provides an effective way of checking that the IP input signal is complete as regards the services tables it contains When an analysis has been started it can take several minutes to complete In particular the ana
32. rences IP Management Settings 192 fies f1 100 192 168 1 100 0 0 0 0 SNTP Server Note Use 0 0 0 0 for unused or unknown DNS or SHTP addresses Figure 6 IP management configuration Operating Manual U 124 16 programme IP FM converter Sli 6 3 U 100 settings Under U 100 Rack Settings an address can be allocated to the relevant base device The num ber of the currently selected slot is displayed below it U100 Rack Settings Figure 7 Rack settings If the U 124 is managed using the U 100 C controller and there are several U 100 base devices in use then each base device must have a different address The slot address is determined using the backplane coding see chapter 2 8 1 6 4 Saving and loading a configuration Default and reboot The current configuration of the U 124 is always written to the device using the Submit buttons and is therefore activated immediately If you want to save the current status you press the Save 2nd button This current status is then saved on the SD card in the U 124 You can call up this status again using the Load 2nd button Saving the configuration on the local computer or FTP server is explained in the Update chapter Figure 8 Saving and loading default and reboot Save settings to flash Load settings from flash Default settings Reboot system Save 2nd All settings are saved to an alternative config Load 2nd All settings are loaded from an
33. s e g U 124 and power units also in the operating mode of the U 100 Replacing power units After the screws on the cover of the power unit chamber ASTRO logo are removed the power units can be pulled out by hand forwards along the mounting panel When power units are being installed there should be no contact with the ventilator or the fan grid and only the mounting panel attached to the power unit should be used When the tasks are complete the cover of the power unit chamber must be replaced continuous operation of the device is not permitted without this cover Note Do not put your hand or any objects into the power unit chamber The U 100 must only be operated with the original power unit s Replacing converter modules Converter modules can be pulled outwards after the safety screw on the front panel has been unscrewed 2 Technical data for mains supply U 100 SNT 230 V version Mains voltage 100 240 V Mains frequency 50 60 Hz Current consumption 1 4 0 7 A per power unit Protection class according to EN 60529 IP 20 Permitted ambient temperature range 0 45 Secondary fuse in U100 230 T3 15A L 250 V IEC 60127 2 3 Secondary fuses in U 124 SMD various values Operating Manual U 124 16 programme IP FM converter 3 2 8 Installing and coding the backplane A The scope of delivery of every U 1xx signal converter includes a backplane to create the physical connection between the s
34. ssion from the ASTRO company Pictograms and safety instructions Pictograms are visual symbols with specific meanings You will encounter the following pictograms in this installation and operating manual Warning about life endangering situations due to dangerous electrical voltage or non adherence to this manual Warning about various dangers to health the environment and material Recycling all of our packaging material cardboard boxes accompanying papers plastic film and bags is completely recyclable Used batteries must be disposed of at approved recycling points Batteries must be completely discharged before being disposed of Electronic devices must not be disposed of with household waste but rather according to directive 2002 96 EG OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL from 27 January 2003 on waste electrical and electronic equipment must be properly disposed of When they are no longer of use please bring these devices for disposal to one of the public collection points for this purpose Copyright notice Some of the software of this product is third party software which was developed under several different licensing conditions Detailed information concerning the licenses can be found via the Web interface of the device The source code of the free parts of the software is distributed on request for an administration fee Please contact kontakt astro strobel de ASTRO Strobel Kommunikationssyste
35. tered until the U 124 automatically logs the user out if no configuration change has been registered during this period In the lower area of the User Administration table you can enter the name location and respon sible contact person These entries also appear in the top frame eno Sw User Administration RF1 1 RF1 2 RF1 3 RF1 4 RF1 5 ei CEE n RF1 6 RF17 Location HeadendinCablecty Headend Headend in Cablecity eee RF1 8 RF2 1 Contact John Doe admin example com RF2 2 RF2 3 Leave input box empty to keep settings To disable account 2 3 or 4 set an empty username Please use no passwords shorter than five characters RF2 4 RF2 5 Note There ist no hidden password Do not forget your password or you will be locked out RF2 6 RF2 8 ASTRO Strobel Kommunikationssysteme GmbH TS Analyzer Licensing Figure 17 User management Changes must be transferred to the U 124 using Submit Operating Manual U 124 16 programme IP FM converter 10 Transport stream TS analyzer The U 124 can be equipped with a Transport Stream Analyzer by obtaining a licence This Ana lyzer displays the structure of the MPEG2 TS from the tables to the individual PID and its ser vice You click on the TS Analyzer submenu to reach the selection of the transport stream to be analysed When you select a TS in the Analyze line and press the Submit button the selected trans
36. terface the user currently logged in is displayed Operating Manual U 124 16 programme IP FM converter 5 Status When you click on the Status submenu in the left frame the following window appears example A ASTRO EdgeFM U124 TRO BG Name ASTRO EdgefM U124 Location Heacend in Time 25 Ort 2090 09 59 35 UTC Up OG 018 44m 36s ASTRO EGgeFu U124 S r 4021 FY 12 My 1 Caolecity Contact Jonn Doe ASTMC fagefw mis Mam 132 200 1 246 a 198 0 4 06 e mt252 2ef is Logger 18 Ethernet HAC 00 17 72 02 01 de 09 177203 01 de 001772040106 0017722052 26 Address 192 168 62 192 168 5 162 102 66 3 162 102 188 4 162 Eth t t t Subnet 2552452550 255 255 2550 2452552950 258255 2850 ernet Status Gateway 192 468 00 192 148 5 100 tod 683 100 192 168 4 100 Mode Gots Sul ager owe Gbt fut duper Got fur oup Transm 6 185 utes 6 005 Linon 6 000 ees 0 000 Linge Recewa 0 616 Moos 0 000 Mts 441 714 Mbps 441 713 Ubps IP RX Channels A preter a 23219 100 124 OO 020028003 1528 bites 31787 MOPS 4449 s Status display of IE 8x1 pacten nore 1113 1 K MEDIA BROADCAS u Primar 233 19 100 134100000000 000020002 RTP UDPP MA PCR the IP receivers 232 19 100 128 100000000 000020225 1328 bytes em LANKA Tp fone Margen 1002 1 Bayern t ARD ER 23219 100 128 10000 0000 000000003 RTPUDPIP 232 19 300 132100000000 0020225500 1328 bytes pag Amera fpem none 36008 VU tory sea TOF vn Pre 295 49 100 132 100000000 000022800 ater Ma PCR 23
37. y saved update files onto the device Here it is recommended to use a TFTP programme The procedure is described in the following section using the Tftpd32 programme Operating Manual U 124 16 programme IP FM converter Datei Organisieren Favoriten BE Desktop dip Downloads X Zuletzt besucht Bearbeiten Ansicht ffnen Extras 2 Erennen Mame tftpd32 exe tftpd32 chm t tftpd32 ini zx Computer System C amp Programme x55 Heuer Ordner k Tftpd32 ullx Anwendung 09 Gr e 183 KB 3r KB 3be KB dat s bin A man e bin man s bin mpeg bin pal s bin Pha ra ul La Lad zu lid Lid c ca c Li Lx Lu Lid x 2 Erstelldatum 09 03 2010 16 19 Figure 21 Example view of the U 124 folder with files and tftpd32 TFTP programme update update The tftpd32 programme is started directly from the folder with the U 124 update files In the window that appears you first press the Settings button then enter the settings according to Figure 21 gt Tftpd32 by Ph Jounin e BE l m Base Directory Current Directory C Users User Desktop U26x Update Browse Browse Server interfaces 192 168 1 40 v ShowDi Global Settings v TFTP Server TFTP Client SNTP server Syslog Server m DHCP Options v Ping address before assignation IV Persistant leases Bind DHCP to this address 5 r Syslog server