1. adjustable 10 Screen illumination automatic deactivation Installation Instructions Installation tips Do use the enclosed installation stencil Attach the DCC 6000 within the cut out using the enclosed screws Electronic connection WARNING Short circuit danger and fire risk Please follow all safety regulations when working with electronic devices Write down theconnections and only then remove all PLUS cables from the batteries before you begin connecting the DCC 6000 Only when all other connections to the DCC 6000 have been made is it safe to reattach the cable to the battery The connections are in the back of the device Connecting the DCC 6000 1 Supply voltage for DCC 6000 red 2 Supply voltage for DCC 6000 blue 3 Voltage measurement for second battery green 4 Voltage measurement for second battery Both battery negative poles must be connected in the system mass together 5 Shunt connection white 6 Shunt connection yellow Optional Connections for control outputs 7 Output for under voltage warning control exit 8 Output for under voltage warning control exit 9 Output for warning of deep discharge control exit adjustable 10 Output for warning of deep discharge control exit adjustable 11 Supply voltage for control exits 12 Supply voltage for control exits Upon connecting the DCC 6000 the screen will shows the factory set
2. reading changes to V Volt on the second input This is how you can read the tension of a second battery Requirement the battery systems have to be connected Middle key When using this key Ah reading rest capacity switches go rest capacity Technical Data Supply voltage 8 50V DC Current drain without lighting lt 4 mA with lighting lt 6 mA Metering capacity depending on Shunt 1 0 002 50 A 0 001 999 90 Ah Shunt 2 0 01 500A 0 001 999 90 Ah Shunt 3 0 1 5000A 0 001 9 999 0 Ah Measuring procedures Sigma delta automatic comparison Correction factor Peukert 1 1 Temp area 20 C to 60 C Measuring accuracy 0 1 2 Digit Loading capacity of outputs 100 mA Screen LCD background lighting visible surface 35 00x75 00mm Fitting dimensions H 59 0 x B 140 0 x D 28 5 with clips 40 0 mm use the installation stencil Outside dimension front screen H 65 0 x B 145 0 mm Weight 160g Note By interruption of the electricity supply all programmed settings remain and are reinstated when the device is turned back on
3. when the capacity limit is recharged It now shows the current battery capacity By the activating the control exit this is deactivated After programming all your desired settings you can leave the menu by pressing both arrow keys simultaneously press briefly You will see a YES on the screen on the upper right side Press the middle key to confirm your setting This concludes your programming phase If you wish to make changes to the programming you have the ability to press the lower arrow key press and discontinue to programming with no All settings revert to the prior state Ah counter setting reset This function is to be applied only if 1 the DCC 6000 is used for the first time with the gauging battery 2 when there has been a capacity setting change under P 3 In order to wrap up the programming after afore mentioned changes the DCC 6000 readings have to be adjusted as follows 1 Operate the middle key and hold down 2 then additionally press both arrow keys You will now see the reading in Ah which you entered under P3 previously By using the middle key you will now see the reading 100 a bar graph also shows 100 0 Operating Instuctions Upper arrow key Illumination The screen illumination is switched on and off by using the upper arrow key If the illumination remains on it automatically turns itself off after approx 20 minutes Lower arrow key By using this arrow key the
4. Solarlink GmbH www solarlink de info solarlink de Battery control system DCC 6000 Description and Operating Instructions Dear customer You have acquired one of the finest battery control systems in the world the DCC 6000 Please take note of the sizable screen which at all times makes it easy to read the displayed information In order to use your DCC 6000 effectively you will the need following information Battery capacity see battery The system s voltage 12 or 24 V DC see battery To determine the effective range shunt you will need the maximum values of charge and discharge current Charge factor our experience shows in case of lead accumulation it is usually at 95 with other batteries other values have to be taken into account see programming DCC 6000 Features 1 Charge current indicator in Ampere 2 Discharge current indicator in Ampere with short term repository of maximum storage 3 Continuous indication of charge and discharge currents with on screen arrows 4 Indication of battery s current capacity in Ampere hours both in number and 5 Graphic representation of the output by means of a bar chart 6 Supply voltage indicated at all times 7 Continuous warning as soon as low voltage occurs 8 Warning when battery capacity gets too low adjustable 9 Notice when battery capacity goes from critically low deep discharge gt again reaches sufficient charge
5. tings The discharge current is shown in the right upper field A Provided user and loading equipment are switched off if the value appears 0 A Battery voltage is shown in the left area of the screen V Below the ampere display you will find the ampere hours shown ah The bar chart shows the battery charge in Programming Factory Setting Instrument shunt Shunt Type 2 e g 60A 100A 200A 1 mOhm Battery capacity 100 Ah Charge factor 95 Warning signal with 50 of the battery capacity Warning signal stop with 80 of the battery capacity Peukert rating 1 1 Start Programming In order to adjust the program to given circumstances you must use the keys on the right Operate the arrow keys up and down simultaneously press On the screen the menu choices appear on the left side under P here you can find the reading by using the lower arrow key P 1 which also gives you the choice of looking at the operating tension P 1 Battery Voltage 12 V or 24 V U bt After activating the middle key Set gleaming U bt Using the arrow keys you can choose the voltage 12 V or 24 V see technical data Once the desired setting is chosen confirm it with the middle key The screen now indicates the chosen setting 12 V or 24 V which are the operational voltage of the installation In order to set the other programs please follow the same procedures Chose the desired menu point using the arro
6. w keys use middle key and select the desired setting After choosing the setting confirm with the middle key Call up other program settings as needed P 2 Shunt Choose the type of shunt see technical data P 3 Capacity battery CAP To set the battery capacity the capacity of your battery needs to be in ampere hours look at model plate on battery P 4 Loading factor CHA fa Typically the following settings have to be adjusted with various battery types Lead gel solar batteries approx 95 to 98 Gen lead based batteries approx 90 to 95 NiCad batteries approx 80 The charge is a compensation factor for the DCC 6000 so that it takes into account the efficiency of your battery Batteries take up more energy to charge than they disperse The precise loading factor depends on type and use of the battery P 5 Adjusting the warning signal when the battery s capacity limit falls short AL on By using the arrow key program in the setting at which capacity limit you want to be warned in When the capacity limit falls short the warning signal sets in and shows the remaining capacity on the blinking bar graph It is activated with an open collector exit P 6 Setting the switch off AL OUT OF VISION By using the arrow key program in the setting at which point the alarm signal should be deactivated when sufficient battery charge has been reached enter in The bar graph stops blinking

Download Pdf Manuals

image

Related Search

Related Contents

model gt1300pss user manual pneumatic torque  Toastess TBL634 User's Manual  manuale alimentatore  Philips Shaving foil HP1057/01  Micro System USB EV-239  Craftsman 40 in. Rear Mount Dethatcher Owner's Manual    Fellowes P-35C User's Manual  Snapper 4084 User's Manual  Stand Mixer Multifunction Robot Pétrin Multifonction Robot Mixer  