OPERATING INSTRUCTIONS for fl ow meters of the product line “Ex

image

Contents

1. Figure 3 Circuit diagram of the isolated switching amplifier MK 13 P Ex0 24 V DC K15 The flow meter outputs a digital signal that is processed further in the isolated switching amplifier Since the signals are transmitted using an impressed electrical signal only two wires are needed in the transmission cable to transmit the signal From the electrical signal the isolated switching amplifier generates the positively switching output signal PNP signal and the inverted positively 10 Low Signal lt 2 7 mA High Signal gt 3 7 mA switching output signal PNP signal Normally the signal processor only needs the standard signal generated see figure 3 and figure 4 the inverted signal is only processed in special cases That is why the inverted signal is only shown in the circuit diagram as a dotted line One volume measurement 1V Figure 4 Signal output of the isolated switching amplitier Note Signal VSE measurement Inverted signal Note that the signal output of the isolated switching amplifier is a PNP signal low signal open output high signal U Problems may arise when the signal processor has high impedance inputs especially in the higher range of flow rates The signal edges become rounded and the signal processor cannot detect the digital sign
2. VSE measurement Certificate of Complience FM Approvals Member of the FM Global Group FM Approvals 1151 Boston Providence Turnpike P O Box 9102 Norwood MA 02062 USA T 781 762 4300 F 781 762 9375 www fmglobal com CERTIFICATE OF COMPLIANCE HAZARDOUS CLASSIFIED LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment Type VS q 3201 and Type EF Q Volume Sensors IS I 1 ABCD TA Ta 20 80 4 F 176 F TS Ta 20 70 C 4 F 158 F T6 20 C 55 4 F 131 F Entity Entity Parameters Vua 18 5 V 24 mA 100 mW 0 27 uF L 0 mH a Housing E 303 Stainless Steel 1 4305 G Grey Cast Iron GGG40 The EF Type consists of aluminum The preamplifier housing AK 061 consists of aluminum Options not affecting safety any single digit letter or number referring to non electrical properties as product associates language delivery packing documentation etc 1 06 3026920 Page 1 of 3 38 VSE measurement FM Approvals Member af the F Goba Croup Equipment Ratings Intrinsically Safe with Entity Parameters for Class I Division 1 Groups A B C amp D hazardous classified locations FM Approved for VSE Volumentechnik GmbH H nnestrasse 47 58809 Neuenrade Germany 1 06 3026920 Page 2 of 3 39 VSE measurem
3. Before you operate the flow meter you must carefully clean and rinse the entire system so that no foreign particles from the installation can get into the measuring unit of the flow meter The pipes and the flow meter must always be filled in operation so that no gas bubbles can form Extremely dirty media or foreign particles in the medium can block damage or even destroy the measuring unit In these cases you should always install a sufficiently rated filter before the flow meter so that no foreign particles or substances can get into the measuring unit and damage the flow meter The VSE flow meters are not authorized for use in areas subject to a dust explosion hazard To suppress inductive interference you must use the connection cable in which the shield is seated on the union nut of the four pin circular connector when installing the flow meter In hazardous areas the flow meter is connected to a ground potential You must be extremely certain that there is an equalization of potential between each end of the circuit i e between the hazardous and non hazardous areas The potential equalization of the ground conductor PE must be present throughout the entire area The owner must maintain the system in proper operating condition operate the system properly monitor it constantly perform the necessary maintenance and any related work immediately and follow the relevant safety regulations when doing so This procedure known
4. Maximum operating pressure Before installing the flow meter you must make sure that the maximum following operating pressures are permitted depending on flow meter operating pressure of the system does not exceed the maximum permissible operating pressure of the flow meter Also note the peak Flow meter in grey cast iron version 315 bar 4500 psi 450 6500 psi pressures can arise when operating the system Flow meter in stainless steel version Important Please consult VSE for all operating pressures gt 450 bar 6500 psi and for special versions Statement to EU Directive 97 23 EG Pressurized devices VSE flow meters are pressurized devices according to article 1 paragraph 2 1 4 of above mentioned directive Therefore they are subject to the regu lations to this directive According to article 3 paragraph 1 4 VSE flow meters have to conform with the technical requirements of the guideline The fluids to be measured are belonging in most of all cases to the class 2 defined in article 9 para graph 2 2 VSE flow meter do not reach the limit values as defined in article 3 paragraph 1 1 The technical requirements for VSE flow meters therefore are limited to the parts indicated in article 3 paragraph 3 It means the devices have to be designed and manvfactured in conformity with acknowledged engi neering such as practiced in one of the member states This is herewith c
5. 60079 14 FM 3600 The sum of the maximum effective capacitance C and inductivity L of the flow meter and the four pin connection cable may not exceed the maximum values C C and L L of the corresponding isolated switching amplifier Pay attention to the manufacturer s specifications for the connection cable and to the lengths of the cables used It must be especially observed that the radial thickness of the insulation of a conductor for conventional insulation materials e g polyurethane have a minimum thickness of 0 2 mm The diameter of a finely stranded conductor must not be smaller than 0 1 mm The ends of the conductor have to be protected against fanning out e g by ferrules In addition to this the sheath insulation must be tested in respect of electrostatic charge to ensure a safe use in the intrinsically safe area The VSE Ex cable corresponds to these requirements It must be especially observed that for the use of devices with two channels there exist two intrinsically safe power circuits in a cable Here please observe chapter 12 2 2 7 8 of EN60079 14 An installation firm and protected against damages is always necessary for this kind of operation The permissible ambient and media temperatures in the correspon ding temperature class may not be exceeded at any time when operating the flow meter When operating or performing maintenance or repairs on the flow meter the surface of the flow meter housing must be
6. unrestricted max 72 db A 90 30 max 1 1 15 max Aluminum IP 65 315 bar 4500 psi 450 bar 6500 psi Flow response curves VS 0 02 VS 4 VS 0 02 Flow resistance A p Flow resistance A p Flow resistance A p VS2 Flow resistance A p 87 02 72 52 87 02 28 00 145 04 116 03 87 02 58 01 29 00 111107 NDR p tt 1000 cSt 500 cSt 1 VS 0 04 Flow resistance A p VS O Flow resistance A p Flow resistance A p VSA Flow resistance A p 87 02 72 52 58 01 43 51 29 00 2 145 04 116 03 87 02 29 00 145 04 116 03 87 02 203 05 174 04 145 04 116 03 58 01 29 00 VSE measurement 1 2 3 4 5 7 10 11 12 13 14 15 16 l min 16 1 18 2 38 3 57 GPM 4 76 23 VSE measurement Dimensions VS 0 02 VS 4 Stainless steel version Cast iron version i Connection diagram View X Earth Housing without miled edge Centering bore hole Plug position for VS 0 02 to VS 0 4 and VS A Cast iron version Connection diagram Earth View X IIC 6 4 X E071 X ll 1 G EEx L3 BVS 05 A ll 1 G EEx II C T6 T4 Uis 185V i LIV 5 M12 x 1 Plug position for VS 1 VS 2 0 02 100 80 91 M 12 5 9 114 58 70 AO 20 1 x2 2 8 3 4 0 04 10
7. 82 296 700 K13 P Ex0 24VDC MK13 P Ex0 24VDC MK13 N Ex0 24VDC MK13 N Ex0 24VDC MK13 R ExO MK13 R ExO MK13 P Ex0 24VDC K15 MK13 P Ex0 24VDC K15 Notes 1 The symbol 19 designates any of the following e For US jurisdictions Any FM approved intrinsically safe apparatus with Entity Concept parameters or any simple apporatus e For Canadian jurisdictions Any Canadian certified intrinsically safe apparatus with Entity Concept parameters or any simple apparatus The Entity concept allows interconnection of intrinsically safe apparatus and associatedopparatus not specifically examined in such combination as a system when the conditions above are met Vmax gt Vt Imax 2 Iscor It U 2 Uo 2 lo Pi gt o Ci Ccoble lt Co Li Lcoble lt Lo Ci Ccoble lt Co Lit Leable lt Lo A simple apparatus is defined as an electrical component or combination of components of simple construction with well defined electrical parameters that does not generate more than 1 5V 100mA and 25mW or a passive component that does not dissipate more than 1 3W and is compatable with the intrinsic safety of the circuit in which it is used When the field device is a contact closure the connection should be made as shown below for proper performance Ri must be Iknto 2 2kn With line monitoring enabled h li 9 R2 must 226 Wit ine monitoring disobled 7 Wiring methods must be in accordance with Fo
8. Ambient temperature 20 49 lt S 95 C 203 F 20 C 4 F ST S 70 C 158 Media temperature 20 4 F ST S 100 C 212 F 20 C 4 F T lt 75 C 167 F FM TA T5 Ambient temperature 20 C 4 F lt T lt 80 C 176 F 20 C 4 F lt 70 C 158 F Preamplifier block wiring diagram Hazardous area Safe area Switch amplifier brown 1 Te x x Equipotential bonding 8 2 Volts T T 2O0 CIAPEIST ss5 G iglep 20 C A F lt T S 60 C 140 F T 20 C 4 F ST 8 55 C 13T F MK 13 P Ex 0 24 V DC K15 VSE measurement Summary of the safety related technical data Flow meter VSE connecting cable blue RAL 5015 Switching amplifier Type VS 32Q1 shielded 4 x 0 34 mm Type MK13 P Ex0 24 V DC K15 BVS 05 ATEX E 071 X PUR PTB 06 ATEX 2025 FM ID3026920 FM ID3026920 EEx ia IIC T4 T6 II 1 G EExia IS Div 1 GRPS A B C D TA T6 Hazardous Locations Div 2 GRPS A B C D IS Entity Connections Div 1 GRPS A B C D 18 5 R 0 053 U 9 9 V ATEX V 9 V 24 mA L 0 85 yH m x 22 mA 19 4 mA P 100 mw C 799 pE m x P 54 mW P 46 6 mW O C 105 pF m x measured at 1000 Hz C 70 27 pF ATEX IIC IIB L mH 1 5 10 2 10 20 C pF 1 1 0 75 065 5 3 5 3 FM A BIC C I
9. C up to 55 C Ambient temperature range with permanently connected cable 100 C Page 1 of 2to BVS 05 ATEX E 071 2 This certificate may only be reproduced in its entirety and without change DEKRA EXAM GmbH Dinnendahlstrasse 9 44809 Bochum Germany Phone 49 234 3696 105 Fax 49 234 3696 110 E mail zs exam dekra com until 31 03 2007 EXAM BBG Pr f und Zertifizier GmbH 40 C up to 95 C 40 C up to 70 C 40 C up to 55 C 35 VSE measurement gt DEKRA conditions The volume sensor has to be mounted in such a way that sparks by operational friction or impact are not possible Test and assessment report BVS PP 05 2049 EG as of 29 07 2009 DEKRA EXAM GmbH Bochum dated 29 July 2009 Signed Signed Simanski Dr Eickhoff Certification body Special services unit We confirm the correctness of the translation from the German original In the case of arbitration only the German wording shall be valid and binding 44809 Bochum 29 July 2009 BVS Schu Her A 20090571 DEKRA EXAM GmbH 2 gt A M Certification body Special services unit Page 2 of 2 to BVS 05 ATEX 071 X This certificate may only be reproduced in its entirety and without change DEKRA EXAM GmbH Dinnendahlstrasse 9 44809 Bochum Germany Phone 49 234 3696 105 Fax 49 234 3696 110 E mail zs exam dckra com until 31 03 2007 EXAM BBG Pr f und Zertifizier GmbH 36
10. T Temperature code based on 55 C 131 F Flow Meter System Series vs 920 i ad EF Qr pm 18 5 V 24 100 mw 270 nF 0 0 Channel 1 V or U Vor 1 max 18 5V 24 mA 100 mW Mom or U Vor max 0 Channel 2 1 The installation must be in accordance with the National Electrical Code NFPA 70 Articles 504 and 505 and ANSI ISA RP12 06 01 2 The flow meter systems series VS 32Q and Q are suitable for use in Class Division 1 and Zone AEx ia applications If connected to associated apparatus the flow meter systems VS 32Q1 ang EF Q may be used in areas classified as zones If connected to AEx ib associated appa ratus the flow meter system may only be used in zone 1 or 2 Hazardous Classified Locations VSE measurement Unclassified Location ASSOCIATED APPARATUS WITH ENTITY PARAMETERS 9 lt V orl lt orl Cone SCFC k L orL FEES Potential Equalisation In order to suppress inductive interference a connecting cable with the shield bearing on the coupling nut of the four pole circular plug in con nect or must be used during the installation of the flow meter In explo sion hazardous areas the flow meter is connected to the ground potential The greatest care must be taken to ensure that between each end of the electrical ci
11. as continuous monitoring will eventually be adopted as a new law in Europe VSE supplies special flow meters from the VS series when the flow meter is to be operated in a hazardous area These flow meters are authorized for use in hazardous areas and must always be operated in conjunction with isolated switching amplifiers that guarantee intrinsic safety and are Ex certified They are marked in blue and offer the safety level required for explosion protection The isolated switching amplifiers must guarantee the ia level DIN EN 60079 11 of intrinsic safety of the signal circuit and their limit values may not exceed the highest permitted input value of the flow meter When equipment is connected electrically a Verification of Intrinsic Safety must be performed EN 600079 14 FM 3600 Even if an in trinsically safe circuit is connected just once to a non intrinsically safe circuit then the piece of equipment is not authorized for use anymore as a device with intrinsically safe circuits This applies to the isolated switching amplifiers as well as the flow meters The relevant appli cable regulations apply to the installation of intrinsically safe circuits the mounting of external connectors the properties and routing of lines and cables Cables and terminals with intrinsically safe circuits must be labeled accordingly and must be isolated from non intrin sically safe circuits or be equipped with the appropriate isolation EN
12. blockage of the gears The owner is responsible for regular inspections maintenance and recalibration The flow meters may not be used in any case when damage or a fault is detected in the meter We advise to a yearly control and recalibration Repairs may only be performed by the manufacturer or by authorized personnel Any other repairs must be examined by an expert Maintenance and repair of devices To ensure fast and economical repair of the flow meters and other components it is absolutely necessary to include a precise description of the problem or error with the package you send back to VSE Furthermore a safety data sheet must also be enclosed in which it is clearly stated which medium was used with this flow meter and any potential hazards the corresponding medium may attribute The legal regulations relating to occupational safety accident prevention regulations regulations relating to environmental protection waste dis posal and water resources law oblige companies their employees and other persons and the environment from harmful effects when handling hazardous substances If additional safety precautions are still required in spite of thorough draining and cleaning of the flow meter then this informa tion absolutely must be enclosed in the package sent back to VSE Note that examination and repair of any flow meters sent to VSE Volumen technik GmbH will only be performed when the safety data sheet of the medi
13. circuit proof transistor outputs output the antivalent digital signal VSE measurement Terminals Z 8 Power supply 7 U 8 GND 0 V Terminals 5 6 5 Output 1 PNP 6 Output 2 PNP LED green Ready for operation LED yellow signal Output 1 U Output 2 open LED off signal Output 1 open Output 2 U LED red fault Output 1 open Output 2 open MK13 P Ex0 Label plate Terminals 3 4 Input circuit monitor disable monitoring connect terminals 3 and 4 Terminals 1 2 Intrinsically safe input circuit 0 2 0 Figure 2 View of the isolated switching amplifier MK 13 0 24 V DC K15 The blue terminals 1 4 of the isolated switching amplifier are equipped safe circuits have been certified by authorized certification agencies and with circuits with the intrinsically safe type of protection for explosion permitted for use in the corresponding countries protection in accordance with 60079 11 FM3600 intrinsically Flowmeter 2 222222222222 P Signal output PNP o 8 2 V ii aS ZU si nal v g x x in x o2 Aus e Fer i 5000 a inv signal 3 fr Potentiol bridge O Ig x wr power for switching off v input circuit 4 1 GN Power supply monitoring er ia GND i _ oq4jdJ
14. coating Type of connection Material Size Subplates AP Product line Modification identification number VSE Standard plug connection no preamplifier integrated standard design externa Power supply volt 5 10 V DC VV GMR 1ex 1 Sensor 2 Sensor GMR Sensor FPM Standard Perbunan PTFE EPDM diminished range normal range standard enlarged range Range steel plain bearings Ball bearings Spindle bearings Bronze plain bearings Carbon bearings Steel bearings No coating Standard Dynamat coating C coating Titanium coating Plate construction Pipe line connections 3 Ges e 57 A Hl H I G EN GJS 400 15 VS 10 EN GJS 600 3 DIN EN 1563 E Stainless steel 1 4305 V2A H EN GJS 600 3 DIN EN 1563 high pressure VS 0 02 VS 0 1 VS 0 4 VS 2 VS 10 VS 0 04 VS 0 2 VS 1 VS 4 Product line Modification identification number Version Accessory connection Connection thread Connection position side Size Material 28 Standard version Special version without rinse connection EN GJL 250 EN GJS 400 15 DIN EN 1561 1563 Stainless steel 1 4305 EN GJS 600 3 DIN EN 1563 A G 1 4 J 1 4 NPT S B G 3 8 K 3 8 NPT T C G 1 2 L 1 2 NPT U D G 3 4 M 3 4 NPT V E G1 N 1 G1 1 4 1 1 4 X G G1 1 2 P 1 1 2 NPT Connection position side Connection below vsoo2 o4 vso4 VS 0 04 VS 1
15. from dirt and contamination when the flow meter is placed in storage or for transportation purposes You must remove these stoppers so that the inlet and outlet are unplugged and open before you mount the flow meter Please clean the pipes and the tank thoroughly since foreign particles and residue in the pipes can get into the measuring unit and block it or even destroy it A blocked flow meter can stop the whole flow You have to provide a control valve VSE measurement VSE supplies bypass plates which are corresponding for all VS flow meter sizes Flow meters are measuring sensors manufactured to high precision They have a mechanical measuring unit consisting of two gears and that are fit tightly with small gaps between them and the housing Even the least damage to the gears or bearings will cause a measurement error For this reason you must always make sure that no foreign particles can get into the measuring unit and that the medium being measured is always completely free from contamination Once the system has been thoroughly rinsed and there are no foreign particles in the piping system you can mount the flow meter and start ope rations Table 2 Pre switched filters Flow meter size Filter size for ball bearings VS 0 02 0 04 0 1 10 pm VS 0 2 0 4 20 um VS 17 27 47 10 50 pm For information on filter size for flow meters with plain bearings in special version or with specially adjusted meter
16. legally required EMC directive EN 61000 VS Ex Type flow meters are authorized for use in areas subject to a explo sion hazard and fulfill the basic health and safety requirements relating to the design and construction of devices and protective systems according to Appendix Il of Directive 94 9 EC ATEX95 and NEC NFPA7O Due to the fulfillment of the European standards EN 60079 0 EN 60079 11 and EN 60079 26 US standards FM3600 FM3610 and FM3810 These devices fulfill the legal health and safety requirements and are certified by accredited certification agencies You will find an EC Type Examination Certificate on page 32 The label for EC Conformity is the CE Symbol which is placed on all flow meters The FM Certificate of compliance is on page 38 Is the medium dirty or is there contamination and suspended particles in the medium What is the size of the particles of the solid material and could they block the meter Are the pipe lines clean and free of scraps left over from the installation such as shavings or weld splatter Is the tank clean and can any foreign material escape from of the tank and into the pipe line system Is the type of medium changed often and is the system thoroughly rinsed after changing Has all air been completely bled from the pipes and the overall system Are the seals suitable for use with the medium to be measured compatible with the seals VSE measurement 2 Hydraulic properties of the syste
17. pages in operating instructions must be replaced immediately VSE can supply you with new operating instructions or you can download the operating instructions from the Internet www vse flow com The operating instructions must be given to each subsequent user of this product Legal Information This document is not managed by an updating service of VSE Volumentechnik GmbH Changes to this document may be made without notice VSE Volumentechnik GmbH does not provide any implicit guarantees of commercial qualities and suitability for a specific purpose If the device has been opened modified or incorrectly connected to the electrical circuits the explosion protection warranty is void and therefore the guarantee of VSE Volumentechnik GmbH for safe operation in potentially explosive areas is void VSE Volumen technik GmbH is not liable in any way for personal injuries or damage to goods resulting from improper installation or improper operation of the flow meter Operating manual No E060034 E Date 31 November 2010 VSE measurement Functional description of the flow meter in areas subject to explosion hazards VS positive displacement flow meters are volume rate measuring sensors based on the meshing gear principle and are designed for use with liquids Two precisely matched gear wheels are enclosed in a very accurately ma chined housing Gear rotation is sensed by a non contacting signal pick up system Each tooth pr
18. rate suddenly increases rapidly and it improves the measurement accuracy at the same time For fluids of lower viscosity lt 21 mm s measurement accuracy deteri orates while for fluids of higher viscosity gt 21 mm s it can improve The higher the viscosity the higher the flow resistance Ap Also note however that the flow meter range is restricted in case of higher viscosity see flow meter data sheet non return valve flow meter Tank Fig 1 Flow meter installation with non return valve Block mounting The flow meter is mounted on a subplate The subplate is installed in the pipe and is equipped with all hydraulic connections and mounting holes required for mounting the flow meter Table 1 Torque of fastening screws Flow meter size Torque cast iron and 1 4305 50 225 5004 50 gt 5 0 2 15 Nm VS 0 4 VS 1 VS 2 35 Nm VS 4 120 Nm VS 10 250 Nm Please note the special instructions for mounting sizes VS 4 and VS 10 see appendix Important significant consequences in certain cases Cleaning and rinsing the pipes before operation Before you operate the flow meter you must carefully clean and rinse the entire system so that no foreign particles can get into the measuring unit of the flow meter when it is being installed Foreign particles can block the measuring unit and damage it so badly that the flow meter is unable to supply any valid measurement values any more and mu
19. safely protected from impact or sharp edges tools or other items The preamplifier housing is made of die cast aluminum The genera tion of impacts and friction especially between aluminum and steel must be prevented so that the production of sparks is ruled out When using the flow meters ExType VS in hazardous areas re quiring category equipment the sensor is to be installed so that sparks from impact or friction can be ruled out Furthermore the ope rator has to judge the suitability of the device for special application You may not change or extend the devices in any way if the modifications were not expressly permitted by the manvfacturer If the preamplifier housing is opened then the explosion protection certification becomes invalid Maintenance and repairs VSE measurement VSE flow meters are basically maintenance free However it is recommended to send the flow meters back to the factory at regular intervals for inspection particularly in difficult applications when critical media are used e g when using abrasive contaminating media or media containing fillers or pigments when high viscosity media are used or when very heavy strain is placed on the measuring unit e g when the flow changes often and quickly In this manner any minor damage can be detected and eliminated early before the damage leads to total failure during production whether the failure is caused by a faulty bearing or a
20. to an explosion hazard The Ex Type flow meters from VSE GmbH are designed to have the intrinsic safety type of protection and are operated with isolated switching amplifiers The amplifiers must guarantee the intrinsic safety of the signal circuit according to specific criteria and parameters and their limit values may not exceed the highest permitted input value of the device A single channel isolated switching amplifier is required to operate the Ex version of the flow meters in the VS series The intrinsic safety 1 15 type of protection means that the energy in the circuit is so low that no sparks arcs or temperatures can be generated that could cause ignition When installing intrinsically safe circuits detailed regulations must be observed Strict requirements are placed on the isolation to prevent the voltage from creeping into the Ex range due to parasitic voltages For this reason intrinsically safe and non intrinsically safe circuits must always be routed separately It is not permitted to install both types together when routing bundling or harnessing cables The European standards basically divide equipment into two different explosion groups Flow meters belong to Group II Electrical equipment for hazardous areas 8 Equipment in Group II are divided further into explosion subgroups and temperature classes IIA e g acetone ammonia benzene pure methane propane IIB e g ethylene city gas light
21. without change Dinnendahlstrasse 9 44809 Bochum Germany Phone 49 234 3696 105 Fax 49 234 3696 110 33 VSE measurement Ww EXAM BBG Pr f und Zertifizier GmbH Translation Ist Supplement Supplement in accordance with Directive 94 9 EC Annex III number 6 to the EC Type Examination Certificate BVS 05 ATEX E 071 X Equipment Volume sensor type VS 3201 and type EF Q Manufacturer VSE Volumentechnik GmbH Address 58809 Neuenrade Germany Description The sensor can be modified according to the descriptive documents as mentioned in the pertinent test and assessment report The Essential Health and Safety Requirements of the modified equipment are assured by compliance with EN 50014 1997 1 2 General requirements EN 50020 2002 Intrinsic safety 17 EN 50284 1999 Equipment Group II Category 1G The marking of the equipment shall include the following x 116 EExia IIC T4 T6 pecial conditions for safe use The use of volume sensors type EF Q in areas where Category l equipment is necessary the sensor has to be mounted in such a way that sparks by operational friction or impact are not possible Test and assessment report BVS PP 05 2049 EG as of 31 05 2006 EXAM BBG Pr f und Zertifizier GmbH Bochum dated 31 May 2006 Signed Dr Jockers signed Dr Eickhoff Certification body k Special services unit Page l of 2to BYS 05 071 X N
22. 0 80 92 M 11 5 115 59 70 40 20 11 x2 2 8 2 0 0 1 100 80 94 M 9 9 117 70 40 20 11x2 28 3 4 0 2 100 80 94 M 979 9 117 61 70 40 20 1 x 2 3 0 27 0 4 115 90 95 9 M8 11 5 16 120 53 9 80 38 34 17 96x 2 62 4 0 5 0 1 130 100 101 M8 12 5 16 124 68 84 72 34 17962202 53 6 8 130 100 118 M8 15 16 141 85 84 2 34 1796x2 62 6 7 8 4 180 140 145 M12 20 30 168 110 A6 95 A5 36 17 x 2 62 14 7 18 4 The dimensions are specified in mm 24 Dimensions subplates AP 02 4 Connection position side Flow meter NIST baju w EL Ret ook Subplate lt gt Connection thread NO O G 1 4 NO NO Cn NO AR O O Cn Co Co Cn Cn Os only for AP 4 U Connection position below Flow meter ECCE Subplate HAIN 54 VSE measurement Thread depth weight M kg _ 115 M8 15 2 7 RR 110 A 25 VSE measurement Technical specifications VS 10 Measuring range Frequency Pulse value K factor l min Hz pulse litre VS 10 LS 525 7 50 2625 00 3 333 300 Measurement accuracy up to 0 3 of measurement value with viscosity gt 20 mm s Repeating accuracy 0 05 under the same operating conditions Materials Cast iron EN GJS 600 3 EN 1563 Gear bearing Ball bearings or steel plain bearings medium dependent Weight 70 kg without subplate Seals FPM standar
23. B D IIA L mH 82 296 700 C pF 3 6 26 210 Temperature class T4 T5 T ATEX T4 Ambient temperature 20 4 FJ lt T 95 C 203 F 20 4 70 158 F 20 C 4 lt lt 55 131 F Media temperature 20 C 4 F lt T S 100 C 212 F 20 C 4 F lt lt 75 C 167 F 20 C A F lt T lt 60 C 140 F di 14 T5 T Ambient temperature 20 4 F lt 80 C 176 F 20 4 F ST lt 70 C 158 F 20 C 4 F s 55 C 13127 31 1 2 3 4 5 6 7 8 9 10 11 12 32 VSE measurement V EXAM BBG Pr f und Zertifizier GmbH Translation EC Type Examination Certificate Directive 94 9 EC Equipment and protective systems intended for use in potentially explosive atmospheres BVS 05 ATEX E 071 X Equipment Volume sensor type VS 3201 and Typ EF Q Manufacturer VSE Volumentechnik GmbH Address 58809 Neuenrade Germany The design and construction of this equipment and any acceptable variation thereto are specified in the schedule to this type examination certificate The certification body of EXAM BBG Pr f und Zertifizier GmbH notified body no 0158 in accordance with Article 9 of the Directive 94 9 EC of the European Parliament and the Council of 23 March 1994 certifies that this equipment has been found to comply with the Essential Health an
24. DC K15 9 Technical data for the isolated switching amplifier MK 13 P Ex0 24 V DC KI15 11 Soge DB s PUTEM PS 12 FM Approved Isolator Borries 16 Installation of VSE flow meters in explosion hazardous 17 Safety instructions for installation and operation in explosion hazardous areas 20 Maintenance and arena 2 Maintenance and repair of devices 21 Technical specifications VS 0 02 54 22 Flow response curves V5 0 02 cesses ERA ERRARE oo E 23 Bla RA t Pr 24 Dimensions subplales 2 4 25 Technical specificalions VS TO dope detta e Otro 26 Flow response curves 510 26 Dimens Ons Vol caus ue ay ee ee gence nr EE 27 Dimensions subplate 0 27 p ce T P 28 Labeling of the flow meters 29 Safety data for flow meter type VS 320 29 Maximum ambient and me
25. I This certificate may only be reproduced in its entirety and without change Dinnendahlstrasse 9 44809 Bochum Germany Phone 49 234 3696 105 Fax 49 234 3696 110 until 31 05 2003 Deutsche Montan Technologie GmbH Am Technologiepark 1 45307 Essen Germany VSE measurement Translation 2nd Supplement Supplement in accordance with Directive 94 9 EC Annex III number 6 to the EC Type Examination Certificate BVS 05 ATEX E 071 X Equipment Volume sensor type VS 3201 and type EF Q Manufacturer VSE Volumentechnik GmbH Address 58809 Neuenrade Germany Description The flow sensor has been tested in acc with EN 60079 and an additional version with permanently connected cable is possible The Essential Health and Safety Requirements of the modified equipment are assured by compliance with EN 60079 0 2006 General requirements EN 60079 11 2007 Intrinsic safety 1 EN 60079 26 2004 Equipment Group II Category 1G The marking of the equipment shall include the following 9 116 Ex ia T4 T6 Parameters each channel Voltage Ui DC 18 5 V Current li 24 mA Power Pi 100 mW Effective internal capacitance Ci 0 27 uF Effective internal inductance Li negligible The temperature class will be defined depending on the ambient temperature range and the medium temperature in accordance with the following table Ambient temperature range 200 e with contain 20 C up to 95 C 20 C up to 70 C 20
26. VS 0 1 VS2 1 vsio Labeling of the flow meters Name and address of the manufacturer CE label Type designation Compliance with directive 94 9 EC compliance Compliance with NEC NFPA 70 Type plates VSE measurement VSE Volumentechnik GmbH H nnestra e 49 58809 Neuenrade Germany CE aise VS k WS TT 1G Ex ia T6 TA IS Div GRPS A B C D T4 16 APPROVED VSE D 58809 Neuenrade Type VS kkk kkk 32Q S N0 Xxx T EUR Bj BVS 05 ATEX E 071 X II 1G Ex ia T6 T4 Ui 18 5V Ri 0 18 5 V li 24mA Pi 100 mW Ri 0 Li 0 Ci 20 27 uF C 158 Safety data for flow meter type VS 32Q1 Nominal values Nominal voltage Mera ON Switching current ano mA gt 3 Maximum values U 18 5V G 027 pF 24 L 0 P 100 mW R 0 gt 2 0 mA lt 4 5 mA Low 1 2 high max1 2 58809Neuenrade Germany V80 02GPO12V 32Q11 1 IS Cl1Div1GRPSA B C D T4 T6 ENTIT YParameters T4 Ta 20 C 4 F to80 C 176 F 5 Ta 20 C 4 F to70 C 158 F T6 Ta 20 C 4 F to55 C 131 F CTL DWD V066064 V066074 VSE Mfg Date xx xx li z24mA Pi 100mW Li 0 Ci 0 27uF APPROVED 29 30 VSE measurement Maximum ambient and media temperatures Temperature class T4 ATEX T4 T5 T5
27. VSE measurement OPERATING INSTRUCTIONS for flow meters of the product line Ex Type VS APPROVED VSE Volumentechnik GmbH H nnestraDe 49 58809 Neuenrade Germany Phone 49 0 2394 61630 Fax 49 0 23 94 616 33 E Mail info vse flow com Internet www vse flow com Table of Contents Page basic Va ee aa 3 Functional description of the flow meter in areas subject to explosion hazards 4 Flos Meter Selecione score pat tup Pr Pte dn pda arie oda itas dp 4 Decoration Contormily see ae proi redes ciu 4 General requirements for operation A Maximum operating pressure sn abt qe d eg ve tee ew io y 3 Statement to EU Directive 97 23 EG Pressurized 5 Flow rale TONGS EM Satur dud quib Ra edt 6 Installing the flow meter oo s us ee 6 Cleaning and rinsing the pipes before 7 eher 7 Flow meters in environments subject to an explosion hazard 8 General information on using devices with intrinsically safe circuils 9 VSE Ex Type VS flow meters 9 Isolated switching amplifier MK 13 P Ex0 24 V
28. agnetic compatibility of the entire system machine or plant is guaranteed General requirements for operation Before installation or operation you must check the following properties of your system and take the following aspects of the corresponding conditions in your system into account for trouble free and safe operation of the system 1 The medium to be processed Is the flow meter suitable for the medium Is the medium viscous or abrasive Are there any fillers or other additives in the medium Is it necessary to install a hydraulic filter before the meter Which types of cleaners are used Can the seals withstand the cleaning agents and medium one tooth pitch This volume is known as the Volume Impulse V and is stated in cc Imp It is used to define the size of a flow meter The Ex Type flow meters of the production series VS are used in explosion hazardous areas The preamplifier of this Ex Type supplies two modula ted digital current signals which are staggered at 90 to one another The frequency of these signals is proportional to the current flow These separate switching currents are digitalized and amplified by two single channel isolation switching amplifiers properties of the devices depend on the type size and measure ment range as well as on the fluid to be measured Please contact VSE for exact type and size specifications All flow meters are tested according to the applicable
29. al any more In this case insert a pull down resistor with a resistance of approx 2 2 4 7 kO parallel to the input of the signal processor see figure 3 Resistor R Technical data for the isolated switching amplifier MK 13 P Ex0 24 V DC K15 Manvfacturer Type designation Operating voltage Residual ripple WSS Current consumption Galvanic isolation Input circuit Operating values No load voltage U No load current Internal resistance R Switch points Open circuit threshold Short circuit threshold Output circuit Voltage drop Switching current per output Switching frequency Ex certified according to Conformity certificate Maximum values No load voltage U Short circuit current Power P Werner Turck GmbH amp Co KG MK13 P Ex0 24 V DC K15 10 V DC lt 10 approx 20 mA Input circuit to output circuit and supply voltage for 250 Test voltage 2 5k V 8 2V 16 4 mA lt 500 OQ 2 9 3 5 mA 0 2 mA lt 0 16 mA lt 12 4 mA Two transistor outputs short circuit proof positive switching lt 2 5 V 00 mA lt 3 kHz PTB O ATEX 2025 FM ID 3026923 lt 9 9 V lt 9 V lt 22 mA lt 19 4 mA lt 54 mW lt 46 6 mW External inductances capacitances and inductances L C EExia IIB EExia Group A B IIC Group C IIB Group D IIA Temperature range T Device label LED indicators Switching state error
30. ance with the National Electrical Code NFPA 70 Articles 504 and 505 and ANSI ISA RP12 06 01 2 The flow meter systems series VS 32Q and EF Q are suitable for use in Class Division 1 and Zone AEx ia applications If connected to associated apparatus the flow meter systems VS 32Q1 ang EF Q may be used in areas classified as zones If connected to AEx ib associated appa ratus the flow meter system may only be used in Zone 1 or 2 Hazardous Classified Locations 12 Unclassified Location ASSOCIATED APPARATUS WITH ENTITY PARAMETERS e L 1 V oru lt 0 d orl lt orl P s P e Potential Equalisation 3 In order to suppress inductive interference a connecting cable with the shield bearing on the coupling nut ofthe four pole circular plug in connect or must be used during the installation of the flow meter In explosion hazardous areas the flow meter is connected to the ground potential The greatest care must be taken to ensure that between each end of the elec trical circuit i e between the explosive area and the non explosive area potential equalisation exists Drawing No V 06 606 4 Date 15 November 2006 Hazardous Classified Location Class Division 1 Groups A B C amp D TA T Note T4 Temperature code based on 80 C 176 F T5 Temperature code based on 70 C 158 F
31. bstances All electrical equipment installed and operated in an explosive atmosphere require approval for the corresponding zones and must be equipped with a special identification plate Areas subject to an explosion hazard are divided into zones The basis for classifying the zones is the probable frequency of occurrence and duration of the explosive atmosphere The division of the areas into zones is done by the company itself which means the customer as an operator is responsible for the division into zones In Europe the zone definitions can be found in EN 1127 1 in the section on fundamentals and methods for explosion protection Further information on zoning is provided in EN 60079 10 and the collection of examples in the explosion protection rules Ex RL For U S the NEC NFPA7O NEC500 and NEC505 supplies to the divisions Technical inspectors from professional societies can also be contacted for help The customer can also always contract explosion protection experts from an association for technical inspection to define the zones In any case you must obtain approval from the board of industrial and trade supervisors The operation of electrical equipment and systems in hazardous are as is subject to very specific legal regulations For this reason only flow meters with the corresponding Ex certification and Ex identification plates in connection with special certified safety equipment are permitted to be used in any areas subject
32. commended to install an additional non return valve in the outlet line Important Series VS flow meters can be mounted with screws on a mounting plate installed in the pipe Whenever possible you should choose large diameter pipes for the piping system and large diameter lines for the hydraulic supply and return This reduces the effect of a pressure drop and lowers the flow rate in the overall system VSE supplies subplates for all flow meters of the VS product line they have various pipe threads and side or rear side connection see subplates data sheet Depending on the provided conditions the installed pipe line the pipe cross section or pipe thread the operator can choose the suitable subplate and incorporate this into the system or machine without additional reductions The flow meter is screwed onto the block or subplate with four DIN 912 cheese head screws The screws are to be pretensed crosswise evenly with the following torques Make sure that the maximum permissible operating pressure specified for the flow meter cannot be exceeded in any operating mode of the system Note the flow rate range of the flow meter which depends on the viscosity of the measured medium Make sure that both the inlet and outlet of the flow meter measuring unit is always completely full and that there is some pressure on the outlet This prevents the creation of gas bubbles and the destruction of the measuring unit when the flow
33. cuits which ope Flow meter I Explosion hazardous atmosphere 2 Channel black 2 Channel blue Normal atmosphere Isolation switching amplifier 1 Channel Normal atmosphere gt Isolation switching amplifier 1 Channel 13 P Ex0 24 V DC K15 General signal processor signal 1 Channel inv signal 1 Channel signal 2 Channel inv signal 2 Channel GND OV U rate separately thus allowing a separate processing of the signals channel 1 and channel 2 As you can see in figure 7 the signals are transmitted through isolation switching amplifiers which operate separately The two systems are fed by two sources of power Since the two signal systems are galvanically isolated from one another and operate independently this type is used in equipment and systems which operate redundantly Even if one of the signal systems fails the other continues to function General signal processor signal 1 Channel inv signal 1 Channel Ui GND1 signal 2 Channel inv signal 2 Channel U 2 GND2 0 V U 2 Figure Z Galvanic isolation between the channels through separate power supply Important VSE Volumentechnik GmbH The connection diagram in figure 6 shows the processing of two channels of the flow meter With this measuring system you can measure the flow rate and volume in both directions of flow 18 The i
34. d NBR PTFE or EPDM Max operating pressure 420 bar 6000 psi Viscosity range 5 100 000 mm s Installation position unrestricted Direction of flow unrestricted Running noise Channel offset lt 80 db A 90 30 max Pulse width repetition rate max Preamplifier housing Aluminum Protection type IP 65 Flow response curves VS 10 10 000 mm s 1000 mm s 280 mm s 100 mm s Flow resistance A p 26 87 02 58 01 M E us EN N ES CAN ERS LEE EE COANE NCE LJ a ig IG iz P N NS 0 50 100 150 200 250 300 350 400 500 525 0 26 42 52 8 79 2 1056 GPM 132 138 6 Fow Q VSE measurement Dimensions VS 10 View X Connection diagram Weight 70 kg The dimensions are specified in mm Dimensions subplate APG 10 APG 10 SGON 1 Weight 21 kg M16 27 Depth Connection surface r Weight 30 kg The dimensions are specified in mm 27 VSE measurement Type key Flow meters VS Ex Type Example VS1 GP012V 32Q11 1 Example AP G1 S C 0 N 1 Connection Preamplifier Signal output Quantity of pick up sensors Sensor pick up system Seal type Meter tolerance Meter bearing Measuring wheel
35. d Safety Requirements relating to the design and construction of equipment and protective systems intended for use in potentially explosive atmospheres given in Annex 11 to the Directive The examination and test results are recorded in the test and assessment report BVS PP 05 2049 EG The Essential Health and Safety Requirements are assured by compliance with EN 50014 1997 1 2 General requirements EN 50020 2002 Intrinsic safety 1 EN 50284 1999 Equipment Group II Category 1G If the sign X is placed after the certificate number it indicates that the equipment is subject to special conditions for safe use specified in the schedule to this certificate This EC Type Examination Certificate relates only to the design examination and tests of the specified equipment in accordance to Directive 94 9 EC Further requirements of the Directive apply to the manufacturing process and supply of this equipment These are not covered by this certificate The marking of the equipment shall include the following x II1G EEx ia IIC T4 T6 EXAM BBG Pr f und Zertifizier GmbH Bochum dated 11 May 2005 Signed Dr Jockers Signed Dr Eickhoff Certification body Special services unit Page 1 of 3to BVS 05 071 X This certificate may only be reproduced in its entirety and without change Dinnendahlstrasse 9 44809 Bochum Germany Phone 49 234 3696 105 Fax 49 234 3696 1 10 13 14 15 16 17 VSE measur
36. dia temperatures 30 Preamplitier block wiring diagram 30 Summary of the safety related technical data 31 Examination Certificate 32 bese CI PEE 38 VSE measurement Important basic information Dear customer dear user These installation and operating instructions should provide you with the information you need to properly install and commission the flow meter in potentially explosive hazardous areas according to the regulations The installation commissioning and testing are only to be performed by trained and qualified personnel with knowledge of the relevant national regulations relating to explo sion protection These operating instructions must be read and followed carefully to ensure proper trouble free and safe operation of the flow meter VSE is not liable for any damage incurred resulting from not complying with the instructions in this operating instruction It is not permitted in any case to open the device These operating instructions for flow meters in the series Ex Type VS from VSE must be stored so that they can be read at any time by the group of authorized personnel Chapters may not be taken out of these instructions at any time A missing operating instructions manual or missing
37. ement BBG Pr f und Zertifizier GmbH Appendix to EC Type Examination Certificate BVS 05 ATEX E 071 X 15 1 Subject and type Volume sensor type VS 32 type EF Q _ Instead of the in the complete denomination letters and numerals will be inserted which characterize modifications without influence on explosion protection 15 2 Description The volume sensor is used for measurement of flow or mass flow of liquids The electrical components of the sensor are mounted inside an aluminium EF Q or a cast iron or stainless steel enclosure Typ VS 3201 The electrical connection is done by a connector 15 3 Parameters each channel Voltage Ui DC 18 5 V Current li 24 mA Power Pi 100 mW Effective internal capacitance Ci 027 pF Effective internal inductance Li negligible The temperature class will be defined depending on the ambient temperature range and the medium temperature in accordance with the following table 20 C up to 95 C 20 C up to 70 C 20 C up to 55 C Test and assessment report BVS PP 05 2049 EG as of 11 05 2005 Special conditions for safe use The use of volume sensors type EF Q in areas where Category 1 equipment is necessary the sensor has to be mounted in such a way that sparks by operational friction or impact are not possible Page 2 of 3 to BVS 05 ATEX E 071 X This certificate may only be reproduced in its entirety and
38. ent FM Approvals Member of the FM Global Group This certifies that the equipment described has been found to comply with the following Approval Standards and other documents Class 3600 1998 Class 3610 1999 Class 3810 2005 Original Project ID 3026920 Approval Granted 2 Zu gt d Subsequent Revision Reports Date Approval Amended Report Number Date Report Number Date FM Approvals LLC ate 22 obert L Martell Jr Assistant Vice President 1 06 3026920 Page 3 of 3 40 VSE measurement VSE Volumentechnik GmbH H nnestraDe 49 58809 Neuenrade Germany Phone 49 0 23 94 61630 Fax 49 0 23 94 61633 E Mail info vse flow com Internet www vse flow com 01 11 www plakart de
39. gram provided gt 5 cable shielding connected to the ground conductor gt 5 there an equalizing conductor connecting the flow meter to the signal processor to eliminate any voltage differences between them 15 flow meter securely connected to the grounded PE conductor gt sthe measuring unit of the flow meter isolated from the grounded PE conductor e g connected using a sleeve If it is isolated then the measuring unit must be connected to the grounded PE conductor gt 15 cable routed to prevent interference and can any stray pulses be coupled gt 15 4 pin round plug of the connecting cable screwed tightly to the connector on the flow meter gt Are the wires on the signal processor connected correctly and properly gt Does the overall system conform to the electromagnetic compatibility EMC directives as required by law gt Are you following all locally applicable regulations applicable rules guidelines and basic requirements for gt r Are the wires on the signal processor and the isolated switching amplifiers connected correctly gt Were the legal regulations and guidelines for explosion protection followed during the installation of the flow meters and other components in the system gt Systems in which a malfunction or failure can lead to personal injury are to be equipped with suitable safety equipment The function of this safety equipment is to be checked at regular intervals
40. h the shield bearing on the coupling nut of the four pole circular plug in connect or must be used during the installation of the flow meter In ex plosion hazardous areas the flow meter is connected to the ground potential The greatest care must be taken to ensure that between each end of the electrical circuit i e between the explosive area and the non explo sive area potential equalisation exists Drawing No V 06 6 13 4a Date 15 November 2006 15 16 VSE measurement FM Approved Isolator Barriers Discrete Input Devices with Intrinsically Safe Field Circuits c US APPROVED HAZARDOUS CLASSIFIED LOCATION Class Diy 1 Groups A B C D Class Diy 1 Groups E F G Class Ill Diy 1 or Class I Zone 1 or 2 Group IC IIB or IIA NON HAZARDOUS LOCATION OR Class Division 2 Groups A B C D MK13 R Ex0 24VDC MK13 R Ex0 12VDC MK13 R ExO MK13 PF Ex0 24VDC MK13 NF Ex0 24VDC MK 13 PN Ex0 24VDC Switching Amplifier Programming _ Jumper MK13 P Ex0 24VDC MK13 P Ex0 24VDC K15 MK13 N Ex0 24VDC Entity Parameters Class Division 1 Class Il Division 1 Class Ill Division 1 Entity Parameters Class Zone O 1 or 2 Voc Isc Po Ca uF La mH Uo lo Po Co uF Lo mH MK13 R Ex0 VDC MK13 R Ex0 VDC MK13 PF Ex0 24VDC MK13 PF Ex0 24VDC MK13 NF Ex0 24VDC MK13 NF Ex0 24VDC ce ee j 19 4 46 6 3 6 26 210 82 296 700 WK 13 PN Ex0 24VDC 15 19 4 46 6 3 6 26 210
41. ing gas hydrogen sulfide IIC e g carbon disulfide acetylene hydrogen The American standards basically determinte in classes and devisions on the properties of the flammable substance and its likelihood that a flamma ble concentration is present The flow meters belong to the Class 1 Devi sion 1 The equipment is also identified for a specific gas or vapor with a grouping and temperature classes The flow meters are permitted for the Groups gt e g acetylen gt e g hydrogen gt C e g ethylen D e g propane The most dangerous substances are placed in Group IIC Atex or Class 1 Devision 1 FM Devices authorized for Group IIC Atex or Class 1 Devision 1 FM can also be operated with substances from Group IIA and Group IIB Atex or Class 1 Devision 2 FM The ignition temperature defined as the temperature at which a mixture self ignites in a fixed test setup is directly related to the temperature class The temperature class specifies the maximum surface temperature of the electrical equipment and must be lower than the ignition temperature of the flammable substance to prevent ignition The ambient temperatures and media temperatures permitted for the Ex Type flow meters are classified according to the corresponding temperature classes and these temperatures absolutely must be observed see page 30 Maximum ambient and media temperatures The Ex versions of the VSE flow meters are li
42. m Is the maximum operating pressure of the system smaller than the maximum permissible operating pressure of the flow meter Is the maximum pressure drop Ap on the flow meter below the maximum permissible pressure drop Is the pressure drop Ap excessively large on the flow meter when the maximum flow rate at high viscosities for example is reached Does the present flow rate within the flow meter correspond to the flow rate range depending on the viscosity Note that the flow rate range is reduced at high viscosities Is the maximum temperature of the medium within the temperature range of the flow meter Is the pipe cross section large enough and are there any large pressure drops in the system Are the hydraulic connections supply and return correctly connected and sealed Does the pump have enough power to operate the system A blocked flow meter can stop the flow throughout the system Is there an overpressure valve bypass present in the system 3 Electronic processing and electrical safety gt Have you selected the best possible flow meter and is it equipped with the proper preamplifier gt Does the power supply voltage applied match the voltage required by the flow meter gt 15 supply voltage provided by the power supply or signal processor sufficiently filtered gt TMXSUI H Does the power supply output the required amount of power gt Was the electrical connection wired according to the connection dia
43. message Ready for operation Terminal box Dimensions Connection Connection cross section Type of protection IEC 60529 EN60529 Operating temperature range 2 10 20mH 5 3 5 3 pF ATEX 1 5 10mH 1 1 0 75 0 65 pF ATEX 82 mH 3 6 pF FM 296 mH 26 yF FM 700 mH 210 pF FM ZO Cu HO C S Ze ie F Il 1 GD EExia ATEX ASSOCIATED EQUIPMENT Suitable for CL1 Div 2 GRPS A B C D hazardous locations with IS entity connections to CL 1 Div 1 GRPS A B C D FM yellow red two color LED green 8 pin polycarbonate ABS Flammability class V O according to 194 be clipped the top hat rail DIN 50022 or clip on on mounting plate Height 89 mm Length 70 mm Width 18 mm Flat terminals with self lifting pressure plates lt 2 x 2 5 mm r 2 x 1 5 mm with wire end ferrules IP 20 25 C 1 1586 11 VSE measurement Control Drawings Hazardous Classified Location Class I Division 1 Groups A B C amp D TA T Note 4 Temperature code based on 80 C 176 F T5 Temperature code based on 70 C 158 F T Temperature code based on 55 C 131 F Flow Meter System Series vs _32Q1 18 5 V 24 100 mw 270 nF 0 0 Channel 1 18 5 P 100 mW 270 nF R 0 Channel 2 1 The installation must be in accord
44. n safety On the type plate you will find the specifications labels The installation and connection of the isolated switching amplifier and the flow meter are only to be performed by trained and qualified personnel authorized personnel with knowledge of the relevant national regulations relating to explosion protection The prescribed distance between the intrinsically safe connections of the isolated switching amplifier and the grounded components and connec tions of other devices must be maintained If not specified expressly in the manual for the specific device the opening of the device for repairs or modifications to the device not performed by qualified experts or the ma nufacturer will result in the invalidation of the Ex authorization Visible changes to the device housing of the isolated switching amplifier e g black or brown discoloration due to heat or any holes and dents indicate a serious error and the device should be switched off immediately in this case In addition the connected flow meter must be inspected Note that the inspection of the device in terms of its explosion protection properties can only be performed by a qualified expert or the manufacturer Operation of the isolated switching amplifier is only permitted within the authorized limits printed on the housing You must make sure that the applicable regulations guidelines directives and general conditions for operation are observed every time before operati
45. ng the device or changing its connections the conditions for appropriate operation and the safety regulations are met the European standards EN 1127 1 EN 60079 10 EN 60079 14 and 60079 17 and the American standards NEC NFPA70O articles 504 505 and ANSI ISA RP12 06 01 These guidelines must be followed and safety related and electrical data required according to DIN EN 60079 0 and FM3600 see 29 Labeling of the flow meters VSE supplies the flow meters with isolated switching amplifier models MK 13 P Ex0 24 V DC K15 Isolated switching amplifier MK 13 P Ex0 24 V DC K15 The isolated switching amplifier MK 13 0 24 V DC K15 allows binary switching states to be transmitted while electrically isolated It has an intrinsically safe circuit and is certified according to II 1 GD EEx ia IIC for the EU For the U S it is suitable for Div 2 GRPS A D hazardous locations with IS Entity connections to CL1 Div 1 GRPS A B C D The input circuit and output circuit are electrically isolated from each other and from the supply voltage An isolated switching amplifier is required to operate the Ex version flow meters in the VS series The input circuit can be monitored for open circuits and short circuits the monitor can be disabled using a wire jumper An error in the input circuit will block the signal output but will not be output as an error message Two positively switching PNP outputs short
46. not perceive this return flow and a measurement error occurs You must always make sure that the grounded conductor PE is correctly connected with the flow meter and that no voltage differences can arise between the grounded conductor PE connections flow meter isolated switching amplifier electronic signal processor To accomplish this always install an extra wire connection about 4 6 mm between each of the pieces of equipment see the PE arrows in the following figures or connect every single PE connection point in a star configuration to a specific location on the grounded conductor PE There is a terminal for this on the measuring unit housing A conductor with a minimum diameter of 4 mm can be connected here Normale atmosphere General signal processor signal inv signal U GND 0V U 17 VSE measurement lt Explosion hazardous atmosphere Flow meter Figure 6 Evaluation of two channels standard circuit As a rule this circuit is used as the standard The electronic processing unit processes the digital signals from channels 1 and 2 and supplies the current The inverted signals of the channels are not required for the evalua tion so that they are omitted and you only need a four strand cable With the figure 7 circuit you can create two autarchic functioning signal sy stems This type of flow meter has two galvanic isolated cir
47. ntrinsically safe electrical equipment can be connected to the intrinsically safe con nections on the isolated switching amplifier All equipment must meet the requirements for operation in the zone specifying the present explosive atmosphere When equipment is connected electrically a Verification of Intrinsic Safety must be performed 60079 14 504 Even if an intrinsi cally safe circuit is connected just once to a non intrinsically safe circuit then the piece of equipment is not authorized for use anymore as a device with intrinsically safe circuits This applies to the isolated switching amplifiers as well as the flow meters The relevant applicable regulations apply to the installation of intrinsically safe circuits the mounting of external connectors and the properties and routing of lines and cables Cables and terminals with intrinsically safe circuits must be labeled accordingly and must be safely isolated from non intrinsically safe circuits Important For the owner operator the most important guidelines for the setup installation operation testing and maintenance of the system in a hazardous area are among others the guidelines ATEX 95 ATEX 137 and VSE Ex Type VS flow meters The VSE flow meters in the Ex Type VS series from VSE are authorized for use in hazardous areas and are always operated together with an isolated switching amplifier They provide the required explosion protectio
48. oduces one impulse The space between the gear teeth when fully enclosed on both sides by the housing constitutes measu ring chambers Fluid flow causes the gears to rotate and the incoming flow is separated into discrete volumes within these chambers i e the volume of liquid passing through the unit will cause rotation of the gears by exactly Flow Meter Selection The right choice rating of the type and size of the flow meter is the deciding factor for the trouble free and safe operation Due to the wide variety of applications and flow meter versions the technical data provided in the VSE catalogs are of a general nature Certain Declaration of Conformity VS series flow meters for areas subject to an explosion hazard have been tested for their electromagnetic compatibility and noise emission according to the EMC regulations and meet the requirements of the applicable legally required EMC directives They cannot be operated independently They must be connected to a power source via a cable and they output digital signals for electronic processing There is a decla ration of conformity available for all flow meters It can be obtained upon request Since the EM compatibility of the overall measurement system also depends on the cable routing on proper connection of the shielding and on every device connected to the system It must be ensured that all components meet the requirements in the EMC guidelines and that the electrom
49. onfirmed Beside this the paragraph declares that these devices must not have a CE marking according to Directive 97 23 EG Therefore we do not issue de clarations of CE and our products are not labelled acc to 97 23 EG VSE measurement Flow meter range The flow meter range specified in the flow meter data sheet refers to the testing fluid hydraulic oil with a viscosity of 21 mm s at a temperature of 20 C For this flow meter range VSE specifies measure ment accuracy of up to 0 3 of the measurement value and a repetition accuracy of 0 05 Important Installing the flow meter The flow meter should be installed in a location with easy access so that it can be easily removed to clean the gears Since flow meters can operate in any mounting position and any direction of flow you can mount them at any location you want in your system When installing the flow meter you must make sure that there is always some fluid remaining in the flow meter and that it can never run dry even when the system is not in operation For this reason the outlet of the flow meter should always be under a slight pressure since this firmly fixes the measuring unit of the flow meter in the fluid column the measuring unit is supported in this fashion by the fluid column and the pipe line cannot drain empty In critical cases or when the pipe can run dry when the system is on standby or stopped it is strongly re
50. r US jurisdictions the Notional Electrica Code ANSI NFPA 70 Article 504 for Division 1 or 2 installotions or Article 505 for Zone O 1 or 2 opplications and ANSI ISA RP12 06 01 For Canadian jurisdictions the Canadian Electrical Code CSA 22 1 for Division 1 or 2 or Zone 1 or 2 installations Associated apparatus must not be connected to any device that uses or generates in excess of 250Vrms unless it has been determined that the voltage is adequately isolated from the associated apparatus If the electrical parameters of the cable are unknown the following values may be used Capacitance 60pF foot Inductance 0 2uH foot Drawing No u Description Dote gt to BE 3000 Campus Drive Plymouth MN 55441 Phone 763 233 7300 Title Control Drawing for MK13 R ane MK13 NF with 1 5 Entity Field Circuits VSE measurement Installation of VSE flow meters in explosion hazardous areas The following figures show the wiring diagrams for flow meters in the VS series for use in areas subject to an explosion hazard Connect each piece of equipment as shown in the diagram Isolated switching am plifiers also contain non intrinsically safe circuits and may not be installed in hazardous areas The non intrinsically safe circuits are to be installed according to IEC 60364 4 4 Flow meters in hazardo
51. rcuit i e between the explosive area and the non explosive area potential equalisation exists Drawing No V 06 60 74 Date 15 November 2006 13 VSE measurement Hazardous Classified Location Class Division 1 Groups A B C amp D TA T Note 4 Temperature code based on 80 C 176 F T5 Temperature code based on 70 C 158 F T Temperature code based on 55 C 131 F Flow Meter System Series vs 32Q1 Channel 1 Channel 2 Terminals Group u PF mH able 1 2 22 82 1 2 C IIB 29 7 296 1 2 D IIA 209 7 700 1 The installation must be in accordance with the National Electrical Code NFPA 70 Articles 504 and 505 and ANSI ISA RP12 06 01 14 Unclassified Location ASSOCIATED APPARATUS Isolator barrier MK13 P Ex0 24 V DC K15 TURCK Isolator barrier MK13 P Ex0 24 V DC K15 Entity Parameters shown in table below e 9 O Isolator barrier MK13 P Ex0 24 V DC K15 Entity Parameters shown in toble o e Qu below Potential Equalisation Power supply 24 V DC The isolator barrier shall be installed in a tool secured enclosure in com pliance with the mounting spacing and segregation requirements of the ultimate application 2 In order to suppress inductive interference a connecting cable with the shield bearing on the coupling nut of the four pole circular plug in connect or mus
52. solation switching amplifier MK13 P Ex0 24 V DC K15 is manufactured by the WERNER TURCK GmbH amp Co KG exclusively for the Ex Type flow meters of the VSE measurement Power Suppl Evaluation Unit U PP y b 1 Channel gt 2 Channel b Conductor PE r3 T d 3 TURCK TURCK r e 1 C j MKILPEXQ MKIXPEXO multi modul modul Eerie Eau 3054 3 64 69 696965 a PE Brown 0 1 Channel Normal atmosphere FW White U 1 Channel Black U 2 Channel Blue U 2 Channel Shielding Explosion hazardous atmosphere DE Fluid Figure 8 Connection of flow meter and isolated switching amplifier Important Persons assigned or contracted to install commission and operate the devices must have appropriate qualifications above and beyond those required for their normal tasks In particular they must have knowledge of explosion protection 19 VSE 20 measurement Safety instructions for installation and operation in hazardous areas Only qualified personnel meaning authorized persons with special explosion protection training are permitted to install explosion protected equipment and systems The qualified personnel must have read and understood the installa tion regulations and the corresponding type Examination Certificates and Declarations of Conformity Work may only be done on the devices in a de energized state
53. st be sent in for repair After completion of the system or installation of the piping you must carefully clean and rinse the entire piping system and the tank first The flow meter must be removed from the piping system to do this You have to mount a diversion plate onto the block or subplate instead of the flow meter so that the fluid can flow through the diversion plate and all extraneous mate rial can be flushed out without obstruction Use a rinsing agent that is compatible with the medium to be used later du ring operation and will not cause any undesired reactions You can obtain the corresponding information from your supplier the manufacturer of the medium or from VSE Important Filtering of liquid Heavily contaminated fluid or extraneous material in the fluid can block damage or even destroy the flow meter In such cases always install a sufficiently large filter in front of the flow meter to prevent damage to the flow meter The necessary filtering depends on size bearing system and model of flow meter Important bypass for the system When mounting the flow meter you must make absolutely sure that the seals are not damaged in any way and are seated correctly in the hydraulic connections of the flow meter Incorrectly installed or damaged seals can result in leakage and a leaky system can have The yellow plastic stoppers in the hydraulic connections of the flow meter protect the measuring unit
54. sted with European standards in the ia instinsically safe when two independent errors occure category and are permitted for use in Group IIC environments They can be used in Zone O 1 and 2 for gases and vapors when the permissible media and ambient temperatures are observed and the installation regulations are followed The FM approved ambient and media temperature for Ex Type flow me ters are determinted in the corresponding temperature classes and must be strictly maintained The Ex Type of the VSE flow meter is evaluated by the American standards of the FM as intrinsically safe IS for operating in Class 1 Devision 1 Groups A B C D and temperature classes 4 6 see page 33 The VSE flow meters are not authorized for use in areas subject to a dust explosion hazard VSE measurement General information on using devices with intrinsically safe circuits DIN EN 60079 0 and FM3600 contain general regulations for the design construction and testing of electrical equipment intended for use in explosive hazardous atmospheres and specifies the contents of the docu mentation provided with the devices For appropriate operation in explosive atmospheres the national rules and regulations must absolutely be observed and followed at all times The following contains some information in particular information on the basic directives from the European Parliament 94 9 ATEX95 and of the U S standard NEC NFPA7O I
55. t be used during the installation of the flow meter In ex plosion hazardous areas the flow meter is connected to the ground potential The greatest care must be taken to ensure that between each end of the electrical circuit i e between the explosive area and the non explo sive area potential equalisation exists Drawing No V 06 6 12 4a Date 15 November 2006 Hazardous Classified Location Class Division 1 Groups A B C amp D TA T Note T4 Temperature code based on 80 C 176 F T5 Temperature code based on 70 C 158 F T Temperature code based on 55 C 131 F Flow Meter System Series vs 920 i ad EF Qr pm Channel 1 Channel 2 Terminals Group opie PF L apie MH 1 2 A B IIC 3 3 82 1 2 C IIB 25 7 296 1 2 D IIA 209 7 700 1 The installation must be in accordance with the National Electrical Code NFPA 70 Articles 504 and 505 and ANSI ISA RP12 06 01 VSE measurement Unclassified Location ASSOCIATED APPARATUS Isolator barrier MK13 P Ex0 24 V DC K15 TURCK 1 Isolator barrier e MK13 P Ex0 24 V DC K15 S Entity Parameters e shown in table below o Potential Equalisation Power supply 24 V DC The isolator barrier shall be installed in a tool secured enclosure in com pliance with the mounting spacing and segregation requirements of the ultimate application 2 In order to suppress inductive interference a connecting cable wit
56. tolerances please consult VSE VSE measurement Flow meters in environments subject to an explosion hazard The operation of flow meters in areas with a hazard of explosion is subject to very specific legal regulations For this reason only flow meters with certified Ex authorization are permitted to be used in areas subject to an explosion hazard To protect people from harm and equipment from damage lawmakers have issued national and international standards containing regula tions that must be followed when using electrical components and systems in explosive atmospheres In Europe CENELEC the European Committee for Electrotechnical Standardization issues harmonized regulations relating to explosion protection for electrical equipment In the U S the re gulations are issued by the ANSI American National Standard Institute A hazard of explosion can arise when handling flammable meaning oxidizable substances when these substances are present as gases e g methane propane vapors mist or dust their concentration in a mixture with air is within a certain range and the quantity of the mixture flammable substance oxygen has reached a hazardous level An explosion would then occur if a suitable source of ignition is present An explosion often causes very high temperatures and high rates of pressure They can injure people and damage buildings or destroy parts of the sy stem or even ignite other flammable su
57. um used is enclosed and the flow meters have been completely cleaned and rinsed This serves to protect our employees and makes ovr job easier When these instructions are not followed the package will be returned at the sender s expense 21 VSE measurement Technical specifications VS 0 02 VS 4 VS 0 02 VS 0 04 VS O 1 VS 0 2 VS 0 4 VS 1 VS 2 VS 4 Measurement accuracy Repeating accuracy Materials Gear bearing Seals Max operating pressure Viscosity range Installation position Direction of flow Running noise Channel offset Pulse width repetition rate Preamplifier housing Protection type 22 Measuring range l min 0 002 2 0 004 4 0 01 10 0 02 18 0 03 40 0 05 80 120 1 0 250 Frequency Hz 1 667 1 667 1 667 1 067 1 250 0 899 4 167 1666 67 1666 67 1666 67 1500 00 1666 67 1333 33 1000 00 1041 67 Pulse value cm pulse 0 02 0 04 01 0 2 0 4 K factor pulse litre 50 000 25 000 10 000 5 000 2 500 1 000 500 250 up to 0 3 of measurement value with viscosity gt 20 mm s 0 05 under the same operating conditions Cast iron EN GJS 400 15 EN 1563 or stainless steel 1 4305 Ball bearings or steel plain bearings medium dependent FPM standard NBR PTFE or EPDM Cast iron EN GJS 400 15 EN 1563 stainless steel 1 4305 100 000 mm s unrestricted
58. us areas are to be connected to a grounding sy stem grounded according to the applicable regulations VSE supplies connection cables for EMC safe operation in which the shield is seated on the union nut of the four pin circular connector It is not necessary for EMC safe operation but it is recommended to connect the shield to a ground connection at the other end of the connection cable i e in the non hazardous area Important The wiring diagram in figure 5 shows the processed signal of one channel from the flow meter With this measuring system you can measure the flow rate and the volume but it is not possible to detect the direction of flow when connected in this manner Flow meter atmosphere I I I lt Explosion hazardous I I I Figure 5 Evoluotion of one chonnel Important Mounting and installation must always be performed according to the locally applicable regulations and the owner of the measuring unit is responsible for abiding by these regulations All installations are to be performed to ensure EM compatibility You must make sure that no voltage differences can arise between the pieces of equipment and must install potential equalization Isolation switching amplifier MK 13 P Ex0 24 V DC K15 PE This processing unit can be used when it is ensured that the flow volume can flow in only one direction When the flow direction changes also short term the receiver does