Home

NuMax S2-118G2 Installation Guide

image

Contents

1. It is advisable to test the depth on a scrap workpiece to determine the required depth for the application To determine depth of drive first adjust the air pressure and drive a test fastener Never exceed 120psi SETTING THE AIR PRESSURE The amount of air pressure required depends on the size of the fasteners and the workpiece material Begin testing the depth of drive by driving a test nail into the same type of workpiece material used for the actual job Drive a test fastener with the air pressure set at 90 95psi Raise or lower the air pressure to find the lowest setting that will perform the job with consistent results It may be possible to achieve the desired depth with air pressure adjustments alone FIRING THE TOOL The tool is specially designed for single sequential mode This mode requires the trigger to be pulled each time a fastener is driven The tool can be actuated by depressing the WCE against the work surface followed pulling the trigger The trigger must be released to reset the tool before another fastener can be driven NUMNIAX WORK CONTACT ELEMENT WCE 1 2 3 Disconnect the air supply from the tool Remove all fasteners from the magazine Make sure the trigger and work contact element move freely up and down without sticking or binding Reconnect air supply to the tool Depress the work contact element against the work surface without pulling the trigger The tool must
2. Each tool is packed with an anti dust cap on the air connector check it after unpacking Keep the anti dust cap cover the air connector when the tool is not in use HTTP WWW NUMAXTOOLS COM 1 888 669 5672 09 MODEL S2 118G2 NUMIDX LUBRICATION The tool is uniquely designed not to need daily lubrication But lubrication is required for best performance after long periods of use Oil for pneumatic fastening tools is added through the air line connection and will lubricate internal parts Do not use detergent oil or additives These lubricants will cause accelerated wear to the seals and bumpers in the tool resulting in poor tool performance and frequent tool maintenance CAUTION Lubricate tool only with specified lubricants CLEANING Avoid using solvents when cleaning plastic parts Most plastics are susceptible to damage from various types of commercial solvents and maybe damaged by their use Use clean cloths to remove dirt dust oil grease etc A WARNING Do not at any time let brake fluids gasoline petroleum based products Penetration oils ect come in contact with plastic parts Chemicals can damage weaken or destroy plastic which may result in serious personal injury COLD WEATHER OPERATION For cold weather operation near and below freezing the moisture in the air line may freeze and prevent tool operation We recommend the use of air tool lubricant or pe
3. loss of power 1 Tool not lubricated sufficiently 2 Broken spring in cylinder cap 3 Exhaust port in cap is blocked 1 Lubricate nailer 2 Replace spring 3 Replace damaged internal parts Fasteners are jammed in tool 1 Guide on driver is worn 2 Fasteners are not correct size 3 Fasteners are bent 4 Magazine or nose screws are loose 5 Driver is damaged 1 Replace guide 2 Use only recommended fasteners 3 Replace with undamaged fasteners 4 Tighten screws 5 Replace driver A WARNING Use only Numax Authorized Repair Parts For questions please call 1 888 669 5672 or visit Quick our website at http www numaxtools com Coupler Air hose QUK asi Oiler Filter Quick d Compressor connector Quick Ay O WEARING PARTS Regulator Coupler p Repair parts can be ordered from our website http www numaxtools com 10 HTTP WWW NUMAXTOOLS COM 1 888 669 5672 HTTP AVWW NUMAXTOOLS COM 1 888 669 5672 11 NUMB MODEL S2 118G2 NONE PGP INC PRODUCT WARRANTIES 1 Year Limited Warranty This warranty of Numax Nail Guns extends exclusively to the original purchaser of the Numax Nailing Gun one 1 year from the original purchase date PGP Inc expressly warrants that the Numax Nail Gun is free from defect in materials and workmanship subject to the exceptions and limitations contained herein 30 Day Limited Warranty This Warranty of PGP INC S driver blades bumpers o rings
4. damage 06 HTTP WWW NUMAXTOOLS COM 1 888 669 5672 MODEL S2 118G2 OPERATION ADJUSTING THE EXHAUST The adjustable exhaust on the cap of the tool allows users to direct the exhaust according to operator preference To adjust the direction turn the exhaust LOADING FASTENERS 1 Connect the tool to the air resource 2 Push down on the latch button B Pull back on the magazine cover C 3 For brad nail Insert a stick of fasteners into the magazine rail D Make sure the pointed ends of the fasteners are resting on the bottom ledge of the magazine when loading 4 For staples set a stick of fasteners on the top of magazine 5 Make sure the fasteners are not dirty or damaged 6 Push the magazine cover C forward until latch button pops up Latch button Magazine cover C CU Nail tips contact y wear rai Raine Magazine ase rail D NUMNIAX Staples Loading way Staples A WARNING The tool may fire when it is first connected to the air resource Always connect the tool to the air resource before loading fasteners to prevent injury from unintended cycling Always make sure the tool s magazine is empty at the beginning of each work session before connecting to an air resource A WARNING Use only those fasteners recommended for use with this tool Fasteners not identified for use with this tool by the tool manufacturer are able to result in a risk of injury to per
5. of flammable liquids gases or dust The tool creates a spark which may ignite flammable liquids gases or dust Keep bystanders children and others away while operating the tool Distractions could result in improper use and cause injury Avoid unintentional misfires Always use caution to avoid accidentally firing Do not point towards yourself or anyone whether it contains fasteners or not PERSONAL SAFETY Do not nail on top of another nail This is able to cause the nail to be deflected and hit someone or cause the tool to react and result in a risk of injury to persons Remove finger from the trigger when not driving fasteners Never carry the tool with finger on trigger the tool is able to fire a fastener Always wear eye protection Operator and others in the work area should always wear ANSI approved safety goggles with side shields Eye protection is used to guard against flying fasteners and debris which may cause severe eye injury You can use the goggles packed with the tool Always wear hearing protection when using the tool Prolonged exposure to high intensity noise may cause hearing loss Use safety equipment A dust mask non skid safety shoes and a hard hat must be used for the applicable conditions Wear a full face shield if you are producing metal filings or wood chips Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away fr
6. this tool until the missing parts are replaced Failure to do so could result in possible serious personal injury A WARNING Do not attempt to modify this tool or create accessories not recommended for use with this tool Any such alteration or modification is misuse and could result in hazardous condition leading to possible serious personal injury FEATURES SPECIFICATIONS REQUIRES 5 87 SCFM with 100 fasteners per minute 90 psi AIR INLET 1 4 inch NPT MAGAZINE CAPACITY 100 fasteners 18 gauge WEIGHT 2 95 Ibs MAXIMUM PRESSURE 110 psi PRESSURE RANGE 60 psi 110 psi FASTENER SIZE RANGE Brad nails from 3 8 to 2 Staples from 1 2 to 1 5 8 0 079 2mm peal 10mm 3 8 16mm 5 8 1 2 13mm 20mm 3 4 3 8 146mm 25mm 1 3y 19mm 30mm 1 3 16 ale 25mm 32mm 1 1 4 1 1 4 32mm 38mm 1 1 2 1 1 2 38mm 40mm 1 5 8 1 5 8 40mm 50mm 2 en 1 26mmy H 0 041 1 05mm Compatible with All Generic 18 Gauge Brad Nails and staples FEATURES 360 ADJUSTABLE EXHAUST Allows user to direct air away from debris COMFORT GRIP HANDLE For increased comfort and control ERGONOMICALLY ENGINEERED BODY Rugged and Comfortable resulting in a light weight tool great for extended use WITH RELOAD INDICATOR Remain nail is seeable NON MARRING TIP Protect working surface from
7. LAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE AND ALL OTHER WARRANTIES IN NO EVENT SHALL PGP INC BE LIABLE FOR ANY INCIDENTAL SPECIAL CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR ANY COSTS ATTORNEY FEES EXPENSES LOSSES OR DELAYS ALLEGED TO BE AS A CONSEQUENCE OF ANY DAMAGE TO FAILURE OF OR DEFECT IN ANY PRODUCT INCLUDING BUT NOT LIMITED TO ANY CLAIMS FOR LOSS OF PROFITS These warranties are the sole and exclusive warranties express or implied for the Numax Product No employee agent dealer or other person is authorized to alter modify expand or reduce the terms of these warranties or to make any other warranty on behalf of PGP Inc These express limited warranties contains the entire agreement regarding express and implied warranties related to the Numax Product No writing or languages in the purchase order or any other document shall be construed as an addition or alteration of PGP Inc s warranties of the Numax Product All matters related to the sale and or use of the Numax Product that is the subject of these limited warranties along with the construction and enforcement of the terms of this limited warranties themselves shall be subject to the laws of the state of Georgia Any dispute arising out of the sale and or use of the Numax Product that is the subject of these limited warranties shall be brought in Cherokee County Georgia Purchase and or use of the Numax Product makes you subject
8. N OMNIS ETE MWe NUMAXTOOLS cOM PRIME GLOBAL PRODUCTS INC MODEL S2 118G2 1SIGA7227B RADINAIWER STAPLER IS amp G amp X AS N S wW e HTTP WWW NUMAXTOOLS COM e 1 888 669 5672 WARNING e PRIME GLOBAL PRODUCTS INC Failure to follow warnings could result in DEATH OR SERIOUS INJURY SAVE THIS MANUAL FOR FUTURE REFERENCE IMN100800AV 12 11 NUMB MODEL S2 118G2 GENERAL SAFETY RULES P3 UNPACKING P6 FEATURES P6 OPERATION ADJUSTING THE EXHAUST P7 LOADING FASTENERS P7 UNLOADING FASTENERS P8 CLEARING JAMS P8 NON MARRING TIP P8 DEPTH ADJUSTMENT P8 SETTING THE AIR PRESSURE P9 FIRING THE TOOL P9 WORK CONTACT ELEMENT WCE P9 MAINTENANCE P9 RECOMMENDED HOOKUP P10 TROUBLE SHOOTING P11 WEARING PARTS P11 WARRANTIES P12 A WARNING The warnings and precautions discussed in the manual cannot cover all possible conditions and situations that may occur It must be understood by the user that common sense and caution are factors which cannot be built into this product but must be supplied by the user SAVE THIS MANUAL Keep this manual for the safety warnings precautions operations inspections and A WARNING To avoid serious personal injury do not attempt to use this product until you read maintenance Keep this manual and the the manual thoroughly and understand it receipt in a safe and dry place for future completely Save thi
9. NING Do not connect with an air compressor which can potentially exceed 200psi As tool may burst possibly causing injury MODEL S2 118G2 NUMNIAX TROUBLE SHOOTING A WARNING Stop using tool immediately if any of the following problems occur Serious personal injury could result Any repairs or replacements must be done by a qualified service person or an authorized service center PROBLEMS Air leaking at trigger valve area POSSIBLE CAUSE S O rings in trigger valve housing are damaged CORRECTIVE ACTION Replace o rings Check operation of Work Contact Element WCE Air leaking between housing And nose Loose screws in housing 1 Damaged O rings 2 Damaged to bumper Tighten screws 1 Replace o rings 2 Replace bumper Air leaking between housing and Cap 1 Loose screws 2 Damaged gasket 1 Tighten screws 2 Replace gasket Tool skips driving fastener 1 Worn bumper 2 Dirt in nose piece 3 Dirt or damage prevent fasteners or pusher from moving freely in magazine 4 Damaged pusher spring 5 lnadequate air flow to tool 6 Worn O ring on piston or lack of lubrication 7 Damaged O ring on trigger valve 8 Air leaks 9 Cap seal leaking 1 Replace bumper 2 Clean drive channel 3 Clean magazine 4 Replace spring 5 Check fitting hose or compressor 6 Replace and lubricate o rings 7 Replace o rings 8 Tighten screws and fittings 9 Replace gasket Tool runs slow or has
10. ad the tool with fasteners Nose plate F Nose screws E A WARNING Make sure there is no fastener in magazine before clearing a jam A WARNING Disconnect the tool from the air source whenever clearing a jam After disconnecting the tool from the air compressor there should still be enough air pressure to fire the tool After the air hose is disconnected always fire the tool into scrap wood repeatedly to make sure all of the compressed air is expended NON MARRING PAD The non marring pad attached the nose of the tool helps prevent marring and denting when working with softer woods A WARNING Disconnect the tool from the air source before removing or replacing the no marring pad Failure to do so could result in serious personal injury DEPTH ADJUSTMENT The driving depth of the fasteners are adjustable To adjust the depth use the drive depth adjustment wheel H on the right side of the tool 1 Disconnect the tool from air resource 2 Turn the depth wheel left or right to change the driving depth 3 Reconnect the tool to the air resource 4 Drive a test nail after each adjustment until the desired depth is set Adjustment wheel H Flush a Turn the adjustment knob counter clockwise HTTP WWW NUMAXTOOLS COM 1 888 669 5672 MODEL S2 118G2 Too Shallow Turn the adjustment knob clockwise Flush Us CAUTION
11. and support the workpiece to a stable platform Holding a tool by hand or against the body is unstable and may lead to loss of control Keep the tool and its handle dry clean and free from oil and grease Always use a clean cloth when cleaning Never use brake fluids gasoline petroleum based products or any strong solvents to clean your tool Do not use the tool as a hammer Never use this tool in a manner that could cause a fastener to be directed toward anything other than the workpiece Never use gasoline or other flammable liquids to clean the tool Never use the tool in the presence of flammable liquids or gases Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury Do not remove tamper with or otherwise cause the trigger lock or trigger to become inoperable Do not operate any tool which has been modified in a like fashion Death or serious personal injury could result Do not touch the trigger unless driving fasteners Never attach air line to tool or carry tool while touching the trigger The tool could eject a fastener which will result in death or serious personal injury Also actuate the trigger lock to the safe position when not in use Always fit tool with a fitting or hose coupling on or near the tool in such a manner that all compressed air in the tool is discharged at the time the fitting or hose coupling is disconnected Do not use a check valv
12. ct air resource Before unloading or making adjustments When maintaining the tool When clearing a jam When touching the safety yoke When tool is not in use When moving to a different work area Such precautionary measures reduce the risk of injury to persons HTTP WWW NUMAXTOOLS COM 1 888 669 5672 05 MODEL S2 118G2 NUMB LOADING TOOL Do not load the tool with fasteners when any one of the operating controls is activated Never place a hand or any part of body in fastener discharge area of tool Never point tool at anyone Do not pull the trigger or depress the workpiece contact as accidental actuation may occur possibly causing injury A WARNING The warnings and precautions discussed above cannot cover all possible conditions and situations that may occur It must be understood by the user that common sense and caution are factors which cannot be built into this product but must be supplied by the user UNPACKING This tool has been shipped completely assembled Carefully remove the tool and any accessories from the box Inspect the tool carefully to make sure no breakage or damage occurred during shipping Do not discard the packing material until you have carefully inspected and satisfactorily operated the tool If any parts are damaged or missing please call 1 888 669 5672 A WARNING If any parts are missing do not operate
13. e or any other fitting which allows air to remain in the tool Death or serious personal injury could occur Never place hands or any other body parts in the fastener discharge area of the tool The tool might eject a fastener and could result in death or serious personal injury Never carry the tool by the air hose or pull the hose to move the tool or a compressor Keep hoses away from heat oil and sharp edges Replace any hose that is damaged weak or worn Personal injury or tool damage could occur Always assume the tool contains fasteners Respect the tool as a working implement no horseplay Always keep others at a safe distance from the work area in case of accidental discharge of fasteners Do not point the tool toward yourself or anyone whether it contains 04 HTTP WWW NUMAXTOOLS COM 1 888 669 5672 MODEL S2 118G2 NUMNIAX fasteners or not Accidental triggering of the tool could result in death or serious personal injury Do not drop or throw the tool Dropping or throwing the tool can result in damage that will make the tool unusable or unsafe If the tool has been dropped or thrown examine the tool closely for bent cracked or broken parts and air leaks STOP and repair before using or serious injury could occur Avoid using the tool when the magazine is empty Accelerated wear on the tool may occur Clean and check all air supply hoses and fittings before connecting the tool to an ai
14. fter handling This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm TOOL USE AND CARE Know this tool Read manual carefully learn its applications and limitations as well as the specific potential hazards related to this tool Use only fasteners that are recommended for your models Do not use the wrong fasteners or load the fasteners incorrectly Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tool s operation If damaged have the tool serviced before using Many accidents are caused by poorly maintained tools Maintain tools with care Keep tool clean A properly maintained tool reduces the risk of binding and is easier to control Store tools out of the reach of children and other untrained people Tools are dangerous in the hands of untrained users Check operation of the tool before use Do not use the tool if the workpiece contact mechanism is not working correctly as accidental driving of a fastener may occur Do not use tool if trigger does not actuate properly Any tool that cannot be controlled with the trigger is dangerous and must be repaired Do not force tool Use the correct tool for your application The correct tool will do the job better and safer at the rate for which it is designed Use clamps or another practical way to Secure
15. not operate Do not use the tool if it operates without pulling the trigger Personal injury may result Remove the tool from the work surface The work contact element WCE must return to its original down position The tool must not operate Do not use the tool if it operates while lifted from the work surface Personal injury may result Pull the trigger and depress the work contact element WCE against the work surface The tool must not operate Depress the work contact element WCE against the surface Pull the trigger the tool must operate CAUTION Check the operation of the work contact element trip mechanism before each use The WCE must move freely without binding through its entire travel distance The WCE spring must return the WCE to its fully extended position after being depressed Do not operate the tool if the WCE trip mechanism is not operating properly Personal injury may occur A WARNING Always know the operational mode of the tool before using Failure to know the operational mode could result in death or serious personal injury MAINTENANCE A WARNING An improperly functioning tool must not be used Do not actuate the tool unless the tool is placed firmly against the work place A WARNING Any time inspection maintenance and cleaning are done Disconnect the tool from the air resource Empty the magazine completely ANTI DUST
16. of other fasteners or with the tool at an overly steep angle as this may cause deflection of fasteners which could cause injury Do not actuate the tool unless you intend to drive a fastener into the workpiece Always handle the tool with care Respect the tool as a working implement Never engage in horseplay Never pull the trigger unless nose is directed toward the work Keep others a safe distance from the tool while tool is in operation as accidental actuation may occur possibly causing injury AIR SUPPLY AND CONNECTIONS The connector on the tool must not hold pressure when air supply is disconnected If an incorrect fitting is used the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not use any type of reactive gases including but not limited to oxygen and combustible gases as a power source Use filtered lubricated regulated compressed air only Use of a reactive gas instead of compressed air may cause the tool to explode which will cause death or serious personal injury Use only a pressure regulated compressed air source to limit the air pressure supplied to the tool The regulated pressure must not exceed 100 psi If the regulator fails the pressure delivered to the tool must not exceed 200 psi The tool could explode which will cause death or serious personal injury Always disconne
17. om moving parts Loose clothes jewelry or long hair can be caught in moving parts Stay alert watch what you are doing and use common sense when operating a power tool Do not use tool while tired or under the influence of drugs alcohol or medication A moment of inattention while operating the tool may cause Serious injury Avoid unintentional firing Keep fingers away from trigger when not driving fasteners especially when connecting the tool to the air supply Keep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations HTTP WWW NUMAXTOOLS COM 1 888 669 5672 03 MODEL S2 118G2 NUMDX Do not use on a ladder or unstable supports Stable footing on a solid surface enables better control of the tool in unexpected situations Make sure the hose is free of obstructions or snags Entangled or snarled hoses can cause loss of balance or footing and may become damaged resulting in possible injury Do not overreach Keep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations Do not attach the hose or tool to your body Attach the hose to the structure to reduce the risk of loss of balance if the hose shifts Always assume that the tool contains fasteners Do not point the tool toward yourself or anyone whether it contains fasteners or not Wash hands a
18. piston rings and gaskets the Numax Wearing Parts collectively with the Numax Nailing Guns the Numax Product extends exclusively to the original purchaser of the Numax Wearing Parts thirty 30 days from the original purchase date due to a defect in material and workmanship PGP Inc shall repair or replace at its option a Numax Product that has a defect in materials or workmanship The original purchaser must return the complete Numax Product postage prepaid and insured with proof of purchase to PGP Inc or any of its authorized service centers Other than the postage and insurance requirement no charge will be made for repairs covered by this warranty These warranties do not apply to defects in materials or workmanship or damages resulting from repairs or alterations which have been made or attempted by others or the unauthorized use of nonconforming parts They further do not apply if the damage is due to normal wear and tear abuse improper maintenance neglect or accident or caused by use of the Numax Product after partial failure or use with improper accessories The Numax Product is intended for use by individuals and not for use on an assembly line production line or any commercial application These warranties do not extend to such commercial use as it constitutes abuse of the Numax Product NO WARRANTY ORAL OR WRITTEN EXPRESSED OR IMPLIED OTHER THAN THE ABOVE WARRANTY IS MADE WITH REGARD TO THIS NUMAX PRODUCT PGP INC DISC
19. r supply Replace any damaged or worn hoses or fittings Tool performance or durability may be reduced Do not use the tool if it leaks air or does not function properly Do not operate the tool if it does not contain a legible warning label Always carry the tool by the handle Never carry the tool by the air hose TOOL SERVICE Use only accessories that are identified by the manufacturer for the specific tool model Use of unauthorized parts or failure to follow maintenance instructions may create a risk of injury Use only the lubricants supplied with the tool or specified by the manufacturer Tool service must be performed only by qualified repair personnel OPERATION Do not drive fasteners near edge of material The workpiece may split causing the fastener or ricochet injuring you or people around Do not carry the tool from place to place holding the trigger Accidental discharge could result Choice of triggering method is important Check manual for triggering options During normal use the tool will recoil immediately after driving a fastener This is a normal function of the tool Do not attempt to prevent the recoil by holding the tool against the work Restriction to the recoil can result in a second fastener being driven from the tool Grip the handle firmly and let the tool do the work Failure to heed this warning can result in serious personal injury Do not drive fasteners on top
20. rmanent antifreeze ethylene glycol as a cold weather lubricant CAUTION Do not store tools in a cold weather environment to prevent frost or ice formation on the tool s operating valves and mechanisms that could cause tool failure RECOMMENDED HOOKUP 1 The air compressor must be able to maintain a minimum of 60 psi when the tool is being used An inadequate air supply can cause a loss of power and inconsistent driving 2 An oiler can be used to provide oil circulation through the tool A filter can be used to remove liquid and solid impurities which can rust or gum up internal parts of the tool 3 Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source if a regulator fails or 150 psi whichever is greater Use 3 8 air hose for runs up to 50 Use 1 2 air hoses for 50 run or longer For better performance install a 3 8 quick plug 1 4 NPT thread with an inside diameter of 315 8mm on the tool and 3 8 quick coupler on the air hose 4 Use a pressure regulator on the compressor with an operating pressure of 0 125 psi A pressure regulator is required to control the operating pressure of the tool between 60 and 110 psi CAUTION The air compressor must be able to maintain a minimum of 60psi when the tool is being used An inadequate air supply can cause a loss of power and inconsistent driving A WAR
21. s manual and review reference frequently for continuing safe operation and instructing others who may use this tool 02 HTTP WWW NUMAXTOOLS COM 1 888 669 5672 MODEL S2 118G2 SYMBOLS NUMNIAX In this manual on the labels packages and all other information provided with this tool The following signal words and meanings are intended to explain the levels of risk associated with this tool SYMBOLS SIGNAL MEANING A WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury A CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Without symbol Indicates a situation that may result in property damage GENERAL SAFETY RULES INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS A WARNING When using tools basic precautions should always be followed including the following CALIFORNIA PROPOSITION 65 A WARNING This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling WORK AREA Keep the work area clean and well lighted Cluttered benches and dark areas increase the risks of accidents Do not operate the tool in explosive atmospheres such as in the presence
22. sons or tool damage when used in this tool A WARNING Keep the tool pointed away from yourself and others when loading fasteners Failure to do so could result in possible serious personal injury A WARNING Never load fasteners with the workpiece contact or trigger activated Doing so could result in possible serious personal injury HTTP WWW NUMAXTOOLS COM 1 888 669 5672 07 MODEL S2 118G2 NUMB UNLOADING FASTENERS Unloading is the reverse of loading Always disconnect the air resource before unloading A WARNING Always unload all fasteners before removing tool from service A WARNING Always disconnect the air resource before unloading CL EARING JAMS Occasionally a fastener may become jammed in the firing mechanism of the tool making the tool inoperable To remove a jammed fastener follow the 1 2 steps below Disconnect the tool from air resource Remove fasteners from the tool Failure to do so will cause the fasteners to eject from the front of the tool Completely remove the small nose screws E and the top nose plate F to reveal the jammed fastener Using caution not to bend or damage the driver blade using pliers or a screwdriver if required to clear the jammed fastener Put the nose plate F back on the nose G fastening it with the screws E Reconnect the tool to the air resource Relo
23. to the benefits and limitations of these limited warranties Accordingly any writ judgment or other 12 HTTP WWW NUMAXTOOLS COM 1 888 669 5672 NUMNIAX MODEL S2 118G2 enforcement obtained from a jurisdiction county parish state or federal court or other country other than from the forum identified above shall be void and unenforceable against PGP Inc Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you If any term or limitation contained in this limited warranty is deemed unenforceable by law then that term shall be severed from the remaining portions of the limited warranties which shall remain enforceable THESE WARRANTIES ARE SUBJECT TO CHANGE WITHOUT NOTICE HTTP AVWW NUMAXTOOLS COM 1 888 669 5672 13

Download Pdf Manuals