Home
US Stove MH6 Installation Guide
Contents
1. 2 Burn paper or cardboard at least three times a week to burn away the products of combustion This is expecially true of thermostatically operated wood and coal burning stoves 3 Do use three sheet metal screws to connect your Miracle Heat to the stove pipe above and below the unit Do not use solder 4 Keep electrical cord plugged in at all times except during servicing to prevent overheating and possible malfunction of components Failure of any part of the heat reclaimer may expose the living space to hot flue gasses 5 Keep the electrical cord at least 12 from contact with the flue pipe INSTALLATION INSTRUCTIONS 1 Do not reduce any minimum clearances which may be listed for your heater in the Owners Manual Only chimneys of Type A all fuel or masonry and lined may be used Check your local or state building codes for proper and safe installation 2 If you have determined your chimney to havean inadequate draft overcome that deficiency before installing your Miracle Heat Your chimney should be capable of developing at least 06 water column draft before installing a Miracle Heat After installation the chimney should develop at least 045 water column as measured below the Miracle Heat All stove pipe above or below your Miracle Heat must be 24 Gauge or heavier to provide adequate support Any horizontal run of pipe must pitch upward toward the chimney at least 1 4 per foot of horizontal run All stove pipe and or
2. IMPORTANT In case of a power failure more than 15 minutes your heater may be kept in use However do not overfire to the point the heat exchange tubes become red hot as such could damage the tubes breaking their air seal 5
3. elbow joints must be secured by at least three sheet metal screws 3 Any elbow installed below your Miracle Heat should be of the non adjustable type 4 Install a hand damper wood and coal stoves BELOW your Miracle Heat 4 5 Power cord must not contact any part of the woodburner or chimney connector If the unit is installed horizontally the power cord must exit the lower side of the unit 6 Only use a heat reclaimer of equal or larger diameter as the flue outlet on the appliance 7 The heat reclaimer should be mounted below barometric draft regulators and draft diverters 8 All electrical supply cord connections shall comply with the requirements of local authorities having jurisdiction 9 Over firing this unit is not recommended 10 The Miracle Heat can be installed in your present flue pipe either horizontally or vertically or at any angle and it may be installed with the crimp end either up or down depending on your needs 11 The Miracle Heat should be installed as close to the flue outlet as possible but no further than 12 from the top or back as shown below 24 GA PIPE DAMPER a LOCATIONTA 1 La 3 SCREWS EACH 050 j HH ofp 3 SCREWS EACH ji NOTE DIMENSION A 12 MINIMUM 24 MAXIMUM 12 Again do not install your Miracle Heat closer than 18 from any combustible material
4. persists shut down your heater or stove and determine the cause If your Miracle Heat is at fault do not attempt repairs but return the unit to United States Stove Company or call our Customer Service Department to arrange for replacement Your Miracle Heat will turn on automatically by virtue of the thermostat shortly after your fire is sarted It will turn off automatically after your fire cools down Do not attempt to alter the thermostat in any way This is not only a cenvenience feature but an important safety device as well CLEANING INSTRUCTIONS Failure to clean your Miracle Heat regularly as described above and below can result in a chimney fire or in smoke spillage from your heater At least twice a year during the heating season remove or have removed by a qualified service man your Miracle Heat from the flue and give the unit a thorough cleaning We further recommend that at least once a day your heater be maintained at high fire for ten to twenty minutes to help burn off unstable creosote be sure of the condition of your chimney before attempting to maintain a hot fire 2 Do not restrict air movement in or around or through the Miracle Heat 3 Do not install on a stove or heater with a flue temperature of less than 350 degrees Fahrenheit 4 Do not install the Miracle Heat closer than 18 to any combustible object or material 5 Do not install the Miracle Heat on a heater or stove which smokes
5. HOW TO ORDER REPAIR PARTS THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DE PENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFER ENCE WHEN WRITING ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE INSIDE OF THE CABINET DOOR OF THE HEATER WHEN ORDERING REPAIR PARTS OR OPTIONS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 The PART NUMBER 2 The PART DESCRIPTION 3 The MODEL NUMBER O 6 O 8 4 The SERIAL NUMBER BEFORE INSTALLING YOUR HEATER FILL IN THE SERIAL NUMBER OF YOUR HEATER IN THE SPACE PROVIDED ABOVE United States Stove Company 227 Industrial Park Rd P O Box 151 South Pittsburg TN 37380 423 837 2100 MIRACLE HEAT OWNERS MANUAL For Models Waste Heat Reclaimer Read these instructions before operating or installing the unit Save this booklet for future reference and guidance UNITED STATES STOVE COMPANY 227 Industrial Park Rd South Pittsburg TN 37380 85627 Congratulations on your purchase of the Miracle Heat Heat Reclaimer a heat efficiency product from United States Stove Company North America s oldest manufacturer of solid fuel appliances Every wood or coal stove or furnace manufactured to date is not totally efficient This means that heat which could be utilized is going up each and every chimney The Miracl
6. The Miracle Heat will aggravate this condition Correct the smoking see chimney and or draft before installing the Miracle Heat 6 Do not plug into an electrical outlet that is not grounded or one that is operated by a wall mounted on off switch 7 Do not interfere with the operation of the fan motor or blades 8 Do not touch your Miracle Heat while it is in operation It is hot and can burn you Also keep children clothing and combustible material away from the unit 9 Do not use stove pipe of less than 24 gauge thickness or of aluminum or galvanized steel DO s 1 Clean your unit periodically at least three times during the heating season Step One Remove the Miracle Heat and clean off any ash or creosote from the pipes Step Two Locate the motor that drives the fan and apply two drops of 20 weight motor oil into each hole Step Three Reassemble your pipes along with the Miracle heat CAUTION Under certain conditions of use creosote may build up rapidly When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote Creosote vapors condense on relatively cool parts of the chimney flue or Miracle Heat and can accumulate to a dangerous level If ignited this creosote 3 If ignited this creosote makes for an extremely hot fire Reduce your possibility of a chimney fire by properly cleaning your Miracle Heat and all connecting stove pipes or elbows
7. authorities having jurisdiction If you are unfamiliar withsuch an installation then do not attempt to install it yourself Have it done by a qualified installer one who is well versed in heating equipment venting its use and safety I DO NOT 1 Do not use a Miracle Heat that has a smaller flue diameter than the flue outlet on your fireplace heater or stove KEY PART NO DESCRIPTION QTY 1 68274 Top Side panel weld Mode 1 68275 Top Side panel weld Model 1 2 22801 Back Bottom panel Model 1 22803 Back Bottom panel Model 1 3 68273 6 Flue pipe tubing Assy Mode 68275 8 Flue pipe tubing Assy Model MH8 1 4 80248 Electric Motor 1 5 89359 Fan blade 1 6 80232 Power supply cord 1 7 89524 M heat front brass trim 1 8 80249 Thermostat 1 9 85630 Product Label 1 10 83348 8x3 8 Pan hd sheet metal screw 18 11 83351 8x3 8 hex hd sheet metal screw 10 12 83324 8 32x1 1 4 machine screw 1 13 83297 8 32 Hex Nut 1 14 80250 Power cord clamp 1 15 83350 Steel spacer 1 85854 M heat UPC code label 1 80252 Closed end connectors 2 83349 8 32 Nylon insert jam L nut 2 E 80109 Strain relief bushing 1 Not Shown OPERATION Before beginning operation double check and insure that all above procedures and steps have been completed Build a fire in your stove or heater as usual As mentioned before there may be smoke and odor for the first five or ten minutes at the most If smoke still
8. e Heat Heat Reclaimer is designed to utilize a part of that lost heat and yet let enough heat pass through the chimney to maintain proper draft and temperature so that creosote and soot formation is keptto a minimum Miracle Heat Heat Reclaimer has a quiet dependable 100 CFM fan that promotes heat circulation to improve overall efficiency The amount of heat actually recovered will depend upon the type of fuel that is burned and the type of heating appliance on which the Miracle Heat is mounted Chimney draft will likewise have a significant effect on the efficient operation of your Miracle Heat The greater your draft the more you need a Miracle Heat But if your draft is insufficient your Miracle Heat will not operate as efficiently and you will possibly contribute to your draft deficiency Your Miracle Heat heat exchanger is designed to work well on nearly every solid fuel stove manufactured but was specifically designed for older model stoves which are less efficient by design If has also proved very effective when used in conjunction with a catalytic damper as the after burned gases from a catalytic damper are themselves quite hot and again represent waste heat though harmful wood products are being burned off GENERAL INSTRUCTIONS Your Miracle Heat should not be installed by anyone inexperienced with such work or not familiar with pre cautions required and not capable of complying with all requirements set by the various