Home
Emberglow BL-101 Instructions / Assembly
Contents
1. THE CHARLESTON SERIES VANGUARD BLOWER MODEL BL 101 FOR VENT FREE UNIVERSAL FIREBOX MODEL NUMBERS VFBC32 VFBC36 A VFBC42 A DESIGN CERT FIED Installation Instructions Circulating Air Blower A WARNING Installer If the information in this manual Leave this manual with the appliance is not followed exactly a fire or explosion may result causing Consumer property damage personal injury Retain this manual for future reference or loss of life INSTALLATION INSTRUCTIONS INSTALLER CONSUMER SAFETY INFORMATION READ AND SAFE THESE INSTRUCTIONS This book contains your installation instructions and should be kept in a safe place For you to realize all of the advantages and use of the reliable service that has been engineered into your Sure Heat Manufacturing Fireplace you must carefully follow all of the instructions contained in this manual regarding installation and operation of the fireplace It is suggested that you wear work gloves and safety glasses to protect your hands and eyes when installing your Blower Kit These Instructions should be read carefully in their entirety before beginning installation of the Blower Kit Electrical Junction Box Wiring should be connected at provided junction box in the firebox prior to the installation of the Blower Kit See instruction on page 3 Electrical Services If an electrical supply of 120V has been roughed in to the fireplace junction box to provide
2. 120V is being roughed in Cover to the fireplace junction box to provide for future 6 Verify operation of outlet assembly in Fireplace installation of the optional blower kit the wiring should be connected to the internal J Box junction box kit PROVIDED WITH THIS ACCESSORY NOTE A FEW BASIC SAFETY RULES BEFORE YOU START 1 All electrical connections Fig 1 are to be made in accordance with CSA Standard C22 1 Canadian Electrical Code part 1 or with the National Electrical Code ANSI NFPA 70 latest edition and or in accordance with local codes 2 Make sure you have and are using wearing proper personal safety devices such as but not limited to gloves safety eye glasses eye protection 3 Check local building codes before installation of the firebox and blower kit 4 All wiring must be installed and or inspected as necessary to comply with the local authority having jurisdiction INSTALLER FIREBOX ENCLOSURE WIRE INTERNAL RECEPTACLE TO 110VAC HOUSE WIRING STEEL HANDI BOX PER APPLICABLE LOCAL CODES W SINGLE GANG BLOWER MOTOR ACCESSORY RECEPTACLE je a oe o o O SPST BLOWER SWITCH VFBC BLOWER WIRING DIAGRAM ALL SIZES Fig 1 Outlet wil be positioned horizontally in models VFBC36 A and VFBC42 A INSTALLATION INSTRUCTIONS Installing Blower Kit Model BL101 Step 1 Remove Blower Access Panel Us
3. 36 and 42 the velcro will be facing the fireplace floor with the outlet of the blower pointed rearward Models VFBC36A and VFBC42A the velcro will be between the blower and fireplace back with outlet of the blower pointing upward Plug Blower Power Cable into supplied receptacle Turn power ON and test unit Replace Blower Access Panel NOTE If you are uncertain or unclear with any instructions or parts STOP and immediately contact the seller or manufacturer listed on these instructions for further explanation and or direction Limited One Year Warranty Limited Warranty shall apply to the original purchaser at the original installation point only The Blower components are warranted for one year to the original owner subject of proof of purchase General Warranty This Limited Warranty will be void if the appliance is not installed by a qualified installer in accordance with the installation insructions The Limited Warranty will also be void if the appliances is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 blower damage by accident neglect misuse abuse alteration negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transportation of defective parts on the appliance or 3 incidental or consequential damage All service work must be performed by an authorized service represe
4. e 1 4 nutdriver to remove four 4 screws The access panel will be located toward the front in models VFBC36A and VFBC42A Step 2 Place Blower Cable in box Route switch terminals through firebox side and then up and out through the switch hole on the Front Side panel on VFBC32 36 and 42 The switch will be located in the front right corner of the fireplace floor on VFBC36A and VFBC42A Step 3 Slide connectors onto the spades on the back of the switch wires can be connected to either terminal Bend tabs slightly downward only on VFBC32 36 and 42 Step 4 Slide Switch and wire terminals back into the switch hole Firmly seat the switch to lock in place INSTALLATION INSTRUCTIONS Installing Blower Kit Model BL101 cont Step 5 Step 6 Step 7 Step 8 a Attach red and black wire connectors to blower motor terminals b Set blower onto firebox bottom c Attach green ground wire to self tapping screw to back firebox panel A DANGER DO NOT ATTACH RED OR BLACK WIRE TO BACK FIREBOX PANEL WIRING DIAGRAM ALL SIZES Peel off backing of Velcro hold down pads insert blower into unit align properly and firmly press down to attach to Firebox Base On models VFBC32
5. for installation of the optional blower kit the wiring should be connected to the junction box NOTE A FEW BASIC SAFETY RULES BEFORE YOU START A Make sure you have and and are using wearing proper personal safety devices such as but not limited to gloves safety eye glasses eye protection B Check to ensure that electrical service has been provided to the junction box located in the bottom chamber of the firebox C Check local building codes before installation of the Blower Kit D All wiring must be installed and or inspected as necessary to comply with the local authority having jurisdiction E The circuit breaker controlling the power supply to the pre wired junction box in the appliance must be in the OFF position before beginning installation of the Blower Kit INSTALLATION INSTRUCTIONS Optional Electrical Junction Box Junction Box Wiring If installation of an accessory blower or other line Voltage powered accessory MAY be desired you should install the J Box accessory and wiring 1 Remove 2 J box retaining screws See Fig 3 at the time of fireplace installation IT WILL NOT BE PRACTICAL TO INSTALL THIS AE ral RO RE SETS INO Tile Pace LATER See Fig 4 Wiring should be connected at a customer provided junction box outside the firebox PATAC Ue eenOle ay ye supply WE Receptacle Electrical Services SO 4 Tighten Cable Clamp install Receptacle and If an electrical supply of
6. ntative This warranty is expressly in lieu of other warranties express or implied including the warranty of the merchantability of fitness for the purpose and of all other obligations or liabilities Sure Heat Manufacturing does not assume for any other obligations or liabilities in connection with the sale or use of the appliance In states that do not allow limitation on how long an implied warranty lasts or do not allow exclusion of indirect damage those limitations of exclusions may not apply to you You may also have the additional rights not covered in this Limited Warranty Sure Heat Manufacturing reserves the right to investigate any and all claims against the Limited Warranty and decide upon method of settlement All costs for removal and reinstallation are the expressed responsibility of the purchaser Servicing Repair and replacement work should only be done by a qualified service person Always shut off the gas supply and make sure the appliance is cool before beginning any service operation For repair or replacement of a defective part or parts contact our Customer Service Department at 1 800 229 5647 You will be asked to provide valid warranty registration proof of purchase and model number Purchased From Date Model BL 101 Name Date Address City State _ _s_ Zip Phone ___ Contact Sure Heat Manufacturing for questions concerning prices and policies covering replacement parts Parts may be ordered th
7. rough your Sure Heat Distributor or Dealer You will need the correct name part number and model number of the appliance when ordering replacement parts Should you need additional information beyond what your dealer can furnish contact Sure Heat Manufacturing 1861 West Oak Parkway Marietta GA 30062 RMH 130 0073 www sureheat com 07 2012