Home
Total Pond LL3600 Installation Guide
Contents
1. LNN ITEM LL3600 Submersible Waterfall Pump TotalP ond 3600 Gallons Per Hour REMINDER Questions problems missing parts Before returning CALL 1 888 412 6001 to your retailer call our customer service department at BEFORE RETURNING TO STORE 1 888 412 6001 8 a m 6 p m EST Monday Friday or email us at customercare geoglobalpartners com Or visit our website www totalpond com PACKAGE CONTENTS Part Description Quantity A Pump 1 B 1 1 2 in and 2 in ID tubing 1 adapter C pump barrier bag 1 A WARNINGS AND CAUTIONS WARNING Risk of electrical shock This pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle Do not exceed the voltage shown on the pump Always disconnect pump from the power source before beginning any maintenance or work on the pump Inspect cord for damage before installation and or maintenance Replace the entire pump assembly if damage is found Do not remove the grounding pin from the power cord plug Risk of electrical shock This pump has not been investigated for use in swimming pools or marine areas CAUTION This pump has been evaluated for use with water only Use a proper power source as indicated on the pump label Keep the cord away from high temperatures or other heat sources Do not pump heated liq
2. er normal working conditions for 20 years from the date of purchase All other TotalPond product is warranted to the user against defective material and workmanship under normal working conditions for 90 days Application Warranty covers only properly installed and maintained units Pump warranty is limited to applications pumping fresh water in a pond or fountain only Other liquid applications or extreme temperature uses must be approved in writing by the manufacturer Receipt and product date code are required for warranty claims Warranty Claim Warranty claims must be made by calling customer service at 1 888 412 6001 If the item is determined to be defective you will be given authorization to return the defective part s freight pre paid along with proof of purchase Disposition The manufacturer will make a good faith effort for prompt disposition regarding all warranty claims Returned product will be inspected to determine cause of failure before warranty is applied Warranty does not cover any costs associated with the shipping handling installation or removal of products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral statements made about the product by the seller the manufacturer the representatives or any other parties do not constitute warranties should not be relied upon by the user and are not part of the contract for sale The sell
3. er s and manufacturer s only obligation and buyer s only remedy shall be for the manufacturer to either replace and or repair at the manufacturer s sole discretion the product as described above Neither seller nor the manufacturer shall be liable for injury loss or damages for lost profits lost sales injury to person or property or any other incidental or consequential loss arising from any cause whatsoever no matter whether based upon warranty contract negligence or other misuse and the buyer and user agree that no other remedy shall be available to them Before using the buyer and user shall determine the suitability of the product for the intended use and assume all risk and liability whatsoever in connection therewith The warranty and remedy described in this limited warranty is an exclusive warranty and remedy in lieu of any other warranty or remedy expressed or implied All other warranties and remedies are hereby expressly excluded including but not limited to any implied warranty of merchantability of fitness for any particular purpose This warranty gives the buyer and user specific legal rights and buyer and user may also have other rights which vary from state to state Some states do not allow exclusions or limitations of incidental or consequential damages so the above limitations or exclusions may not apply to you CALL 1 888 412 6001 BEFORE RETURNING TO STORE
4. perated A drop in water flow is an indication that your pump barrier bag and or pump require cleaning The pump barrier bag not only protects your pump but significantly reduces the need for pump maintenance e Before cleaning always disconnect the pump from the power source e Remove any large debris from pump barrier bag Use a garden hose to rinse off any other dirt from the pump barrier bag e Remove all parts from the pump and clean in warm soapy water e Disassemble the screen and remove the impeller housing to expose the impeller assembly Remove the impeller assembly by pulling on the back round plate behind the impeller e Use a soft cloth or brush to clean the impeller assembly and the inside of the impeller housing Refer to the diagram in the replacement parts list TROUBLESHOOTING If the pump fails to operate e Check to make sure the power cord is plugged in and the pump is getting power e Check the pump outlet and any tubing fountains spitters etc for kinks or obstructions e Remove the inlet screen and or pump cover and impeller housing to expose the impeller Turn the impeller to ensure that it is not broken or jammed Also check to make sure that the ceramic shaft or bearings are not broken If the performance of the pump is not satisfactory or the pump does not flow evenly e Check to make sure the pump is completely submerged in water e Check to make sure the impeller and the housing are clean e Check to make
5. sure the pump barrier bag is clean REPLACEMENT PARTS LIST For replacement parts call our customer service department at 1 888 412 6001 8 a m 6 p m EST Monday Friday Part Description 1 1 2 in and 2 in ID tubing adapter pump barrier bag Impeller housing O ring Impeller Assembly TM O O w Screen PUMP PERFORMANCE Flow Rates Flujo GPH 16 1000 2500 15 1168 2700 14 823 1300 2900 13 955 1489 3059 12 600 1041 1680 3100 2 11 676 1125 1806 3300 c 10 742 1268 2034 3418 2 9 824 1509 2230 3600 18 914 1610 2380 3800 7 1017 1686 2547 4000 a 6 1136 1762 2719 4200 k 5 1242 1893 2832 4400 2 1353 2048 2996 4600 3 1464 2206 3194 4724 2 1596 2367 3387 4900 1 1709 2536 3560 5019 0 1823 2658 3810 5083 LL1200 LL2000 LL3600 LL5100 Waterfall Pumps Bombas para Cascada Printed in China LIMITED WARRANTY All pumps and electrical products are warranted to the user against defective material and workmanship under normal working conditions This warranty period begins on the date of purchase by the original purchaser All TotalPond electrical products are warranted to the user against defective material and workmanship under normal working conditions for 1 year from the date of purchase All TotalPond liners are warranted to the user against defective workmanship und
6. uids Do not let the pump run dry Pump must be completely submerged for proper operation and cooling Operate in fresh water only Avoid heavily chlorinated water and water with high pH levels Do not lift the pump by its power cord PREPARATION Before beginning assembly or operation of product make sure all parts are present Compare parts with package contents list and diagram above If any part is missing or damaged do not attempt to assemble install or operate the product Contact customer service for replacement parts e Estimated Assembly Time 5 minutes e Tools required for assembly hacksaw OPERATION INSTRUCTIONS 1 For maximum water flow it is recommended that the largest tubing size for your pump is used If using 1 1 2 in ID tubing proceed to step 2 If using 2 in ID tubing cut the adapter as shown using a hacksaw Fig 1 Cut ring Fig 1 2 Connect tubing to the outlet of the pump using an adapter ge Tubing NOTE Tubing is NOT INCLUDED Adapter 3 Place the pump inside the pump barrier bag Pull the drawstring until the pump barrier bag is fully closed around the tubing and power cord Tie a knot in the drawstring Fig 3 4 Place the pump into the water and connect to a proper power source Fig 4 CARE AND MAINTENANCE e Clean the pump barrier bag and if necessary the pump regularly depending upon the environment in which it is o
Download Pdf Manuals
Related Search
Related Contents
OEHLBACH i-Jack AD 35/63 Notice de montage et d`entretien Logano plus GB202-15 PP - Plantes et Jardins Clique aqui e faça o do manual de instruções da bomba asciugacapelli - manuale di istruzioni • hair dryer - use Trackspot Special Analog Controller Copyright © All rights reserved.
Failed to retrieve file