1. Anti Tip Bracket Figure 2 Floor Mount 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS C Level and position the range Slide range to its final position Insert the range leveling leg in the anti tip bracket Visually verify if the anti tip bracket is engaged Lower the range by adjusting the 4 leveling legs alternatively until the range is level Check if the range is level by placing a spirit level on the oven rack Take 2 readings with the spirit level placed diagonally take a reading in one direction and then in the other direction Level the range if necessary by adjusting the leveling legs Figure 3 g Leveler P Figure 5 Range NS Leveling p Leg To check if the anti tip bracket is installed properly use both arms and grasp the rear edge of range back Carefully attempt to tilt range forward When properly installed the range should not tilt forward 4 Serial Plate Information The serial plate is located as shown See the serial plate for the following information A Model lot and serial number of range B Kilowatt rating power requirements C Voltage ratings Figure 6 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS 5 Electrical Connection Requirements This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical
2. pared Nota importante al consumidor Conserve estas instrucciones y el Manual del usuario para referencia futura 318201737 1201 Rev A INSTRUCCIONES PARA INSTALACI N DE LA ESTUFA EL CTRICA DE 30 2 Herramientas que va a necesitar Para patas de nivelaci n y montura anti vuelco e Llave ajustable o alicates e Llave para apretar tuercas de 5 16 o un destornillador de cabeza plana e Taladro el ctrico y una broca de a 7 1 8 broca de taladro de hormig n 2 de 5 32 si se instala sobre hormig n Mo al e Nivel amp Cinta de medici n LO M Para la conexi n del suministro el ctrico e Llave de boca tubular o llave para Gl tuercas de 1 4 y 3 8 Materiales adicionales necesarios e Cord n el ctrico o e Alambre el ctrico de cobre y conducto met lico para alambrado permanente 3 Instrucci n para la instalaci n del braquete anti basculante Nota importante de seguridad Para reducir el riesgo de inclinaci n de la cocina sta debe ser asegurada hacia el piso con las fijaciones de anti inclinaci n y los tornillos que vienen con la cocina Si no instala las fijaciones corre el riesgo que su cocina pueda inclinarse si pone demasiado peso sobre la puerta abierta o si un ni o sube sobre sta Esto podr a ocasionar graves lesiones causadas por derrames de l quidos calientes o por la propria cocina Si la coc
3. la estufa Figura 3 Figura 5 Tornillo ex a nivelador a a Fijaciones E estufa de ani S inclinaci n Para verificar si la fijaciones de anti inclinaci n est instalado correctamente sostenga el borde trasero de la parte trasera de la estufa usando ambos brazos Intente inclinar la estufa hacia adelante con cuidado Si est instalada correctamente la estufa no deber a inclinarse hacia adelante 4 Placa de Identificaci n Esta placa de identificaci n est localizada sobre el marco y se puede ver cuando la gaveta est abierta Consulte la placa de identificaci n para obtener la siguiente informaci n A N meros de modelo partida y serie de la estufa B Tasa de kilovatios requerimientos de energ a C Tasa de voltaje INSTRUCCIONES PARA INSTALACI N DE LA ESTUFA EL CTRICA DE 30 5 Requisitos de conexi n el ctrica Este aparato debe estar instalado en forma apropiada y puesto a tierra por un t cnico calificado de acuerdo con el National Electric Code C digo Nacional de Electricidad ANSI NFPA No 70 ltima edici n y con los requerimientos de electricidad de los c digos locales Este aparato puede ser conectado por medio de una extensi n a un tomacorriente local permanente o por medio de Juego de Cord n para el Suministro de Energ a Cuando se use la extensi n no deje exceso
4. a Connect the white appliance cable wire to the neutral white wire b Connect the 2 black wires together c Connect the 2 red wires together d Connect the green or bare copper grounding wire to the grounding wire of the circuit breaker fuse box or junction box Cable from Residence Green or Bare Copper Wire White Wire Green or Bare Copper Wire I White Wire Junction cra Conduit Box Y Connector or CSA Cable from listed Appliance NOTE Be sure to remove the supplied grounding strap _ gt Figure 9 4 Wire Electrical System Example Junction Box 7 Checking Operation Refer to the Use and Care Guide for operation Pee Do not touch cooktop glass or elements They may be hot enough to burn you Before You Call for Service Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance INSTRUCCIONES PARA INSTALACI N DE LA ESTUFA EL CTRICA DE 30 LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO IMPORTANTE GUARDE ESTAS INSTRUCCIONES PARA USO DEL U INSPECTOR LOCAL DE ELECTRICIDAD LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA PARA SU SEGURIDAD No almacene ni utilice gasolina u otros vapores Estados Unidos y l quidos inflamables en la proxim
5. or 24 BACK minimum when bottom of wood or metal cabinet is protected by not VIEW less than 14 flame retardant millboard covered with not less than SS pi no 28 MSG sheet steel 0 015 stainless steel 0 024 aluminum oS SS All dimensions oe or 0 020 copper The minimum clearance is 0 for the rear of the A electrical outlet i l location are maximum range Follow all dimension requirements provided above to prevent Eo y property damage potential fire hazard and incorrect countertop and cabinet cuts Cubed area shows where the electrical outlet must be Avoid locating cabinet storage space above the surface units to eliminate the possibility of cabinets catching on fire or personal burns from reaching for the cabinets over the heated Locallon installed for the units If cabinet storage is to be provided risk can be reduced by range to be flush to installing a range hood that projects horizontally a minimum of EN the wall J 5 beyond the bottom of the cabinets Important Notes to the Installer 1 Read all instructions contained in these installation instructions before installing the appliance 2 Remove all packing material before connecting the electrical supply to the appliance 3 Observe all governing codes and ordinances 4 Be sure to leave these instructions with the consumer Important Note to the Consumer Keep these instructi
6. a uni n listado UL o listado CSA Cable de la estufa NOTA Asegurese de quitar la banda de puesta a tierra gt provista Figura 9 Antes de llamar al servicio Lea la secci n Lista de Antes de llamar en su Manual del Usuario Esto le podr ahorrar tiempo y gastos Esta lista incluye ocurrencias comunes que no son el resultado de defectos de materiales o fabricaci n de este artefacto
7. abajo Si la montura se va a instalar sobre hormig n para suelos cer micos practique un agujero de 3 16 con una profundidad de 1 3 4 Los tornillos que se suministran pueden utilizarse en hormig n o madera Para fijar la montura en su sitio utilice un destornillador de cabeza plana o una llave para apretar tuercas de 516 MONTURA DE SUJECI N MONTAJE EN PARED O SUELO Pata de 1 1 4 Max nivelacion Montaje en pared py Ll Ts N ace No de pared Montaje Montura antivuelco en suelo MONTURA DE SUJECI N s Lo MONTAJE EN SUELO Pata de M s de nivelaci n 1 1 4 2 Pared MU Montaje _ Montura antivuelco en suelo Figura 2 INSTRUCCIONES PARA INSTALACI N DE LA ESTUFA EL CTRICA DE 30 C Nivele la cocina y coloque la cocina en su lugar Deslice la estufa a su lugar Colocar la pata niveladora dentro del braquete anti basculante Verifique visualmente que los soportes antivuelco est n correctamente enganchados anclados Nivele la cocina Nivele la estufa si es necesario ajustando las 4 patas niveladoras con una llave ajustable Para verificar que la cocina esta nivelada coloque un nivel en las parrillas interior del horno Tome m nimo 2 lecturas con el nivel coloque el nivel en diagonal para que la cocina este nivelada de atr s hacia adelante si es necesario ajuste las patas niveladoras f
8. juntos c Conecte los dos alambres rojos juntos Cable de la fuente de alimentaci n Alambre neutro Alamb bl an co A ambres negros Alambres rojos Caja de empalmes Alambre blanco Alambre eat desnudos A Conductor de uni n o verdes EA listado UL listado Cable de la CSA estufa NOTA Asegurese de quitar la banda de puesta a tierra _ _ provista Figura 8 Donde los c digos locales NO permitan conectar el conductor de puesta a tierra del electrodom stico al neutral blanco o si est conectado con un sistema a 4 alambres vea Figura 9 1 Desconecte el suministro el ctrico 2 Siga las instrucciones en la p gina anterior para la conexi n del alambre de cuatro conductores a la cocina Fig 7 3 En el cortacircuito la caja de fusibles o la caja de empalmes Fig 9 a Conecte el alambre blanco del cable del electrodom stico al alambre neutral blanco b Conecte los 2 alambres negros juntos c Conecte los 2 alambres rojos juntos d Conecte el alambre verde o de cobre desnudo de la puesta a tierra del alambre al alambre de puesta a tierra del cortacircuito de la caja de fusibles o de la caja de empalmes Cable de la fuente de alimentaci n Alambre desnudo o verde Alambre Alambres blanco rojos Alambres negros Alambre desnudo o verde T a Alambre blanco Caja de Conductor de empalmes
9. screws do not penetrate electrical wiring or plumbing YG Tip Over Hazard Y e A child or adult can tip the range aS and be killed e Verify the anti tip device has been installed to floor or wall e Ensure the anti tip device is re engaged to floor or wall when the range is moved e Do not operate the range without the anti tip device in place and engaged e Failure to follow these instructions can result in death or serious burns to children and adults A Locate the Bracket Using the Template Locate the bracket position right or left side by placing the template symmetrically to the center of the final range position Mark the location of the screw holes shown on template Figure 1 B Drill Pilot Holes and Fasten Bracket Drill a 1 8 pilot hole where screws are to be located If bracket is to be mounted to the wall drill pilot hole at an approximate 20 downward angle If bracket is to be mounted to masonry or ceramic floors drill a 3 16 pilot hole 1 3 4 deep The screws provided may be used in wood or concrete material Use a 5 16 nut driver or flat head screwdriver to secure the bracket in place FASTEN BRACKET WALL OR FLOOR MOUNTING 1 1 4 Max Leveling leg Rear of Range 2 3 O c mP Floor Mount a Anti Tip Bracket FASTEN BRACKET FLOOR MOUNTING ONLY More than 1 1 4 Leveling leg Rear of Range Wall
10. 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE FOR YOUR SAFETY Do not store or use gasoline or other United States flammable vapors and liquids in the vicinity of this or any other appliance 1 Clearances and Dimensions a Provide adequate clearances between the range and adjacent combustible surfaces b Location Check location where the range will be installed Check for proper electrical supply and the stability of floor c Dimensions that are shown must be used Given dimensions provide minimum clearance Contact surface must be solid and level FRONT _ TYPICAL CABINET INSTALLATION FRONT MEW I VIEW 4 29 7 8 P le 253 4 S _ Minimum to 4 pig 1 Minimum to 9 49 wall on either cabinets on Maximum depth Maximum side of range either side for cabinets above 36 height of range above range top 36 1 8 Vo 42 Door open 30 y HE lt lt 30 1 8 gt 0 clearance below cooking top and at rear of range 30 minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet
11. Banda de d puesta a tierra Una arazadera de releva 1 8 ie A provista debe de estar gujero qe la instalada a est ubicaci n conexi n directa Retira la arandela pre cortada para 1 3 8 3 5 cm Dia agujero Alambre Negro Hacia el 240V Recept culo Figura 6 Conexi n del cable de cuatro conductores a la cocina 1 Retire los tornillos de la parte baja de la cubierta del cable trasero cubierta de acceso para tener acceso al bloque de conexi n del borne terminal 2 Retire la correa de la base del bloque terminal y del armaz n del electrodom stico Retenga el tornillo de la base 3 Utilizar los tuercas suministraron en el paquete de la literatura para conectar el alambre de tierra verde del cable de bronce del suministro el ctrico al armaz n del electrodom stico con el tornillo de la base usando el hoyo del armaz n por donde retir la correa de la base vea figura 7 4 Conecte el alambre neutral blanco del cable de cobre del suministro el ctrico al terminal plateado del centro del bloque terminal y conecte los otros alambres a los terminales externos 5 Baje la cubierta del terminal y vuelva al colocar los tornillos Terminal plata Alambre il Bloque terminal AES Alambre Negro 1 1 8 2 9 cm Dia Agujero de la conexion directa Retira la arandela pre cortada para 1 3 8 3 5 cm dia agujero tierra cable de cobre Un
12. Code ANSI NFPA No 70 latest edition and local electrical code requirements This appliance may be connected by means of permanent Hard Wiring or Power Supply Cord Kit When hard wiring do not leave excess wire in range compartment Excess wire in the range compartment may not allow the access cover to be replaced properly and could create a potential electrical hazard if wires become pinched When using flexible conduit or range cable use flex connector or range cable strain relief NOTE Only use copper wire in connection to terminal block 5 1 Models Requiring Power Supply Cord Kit U S STYLE 3 Wire Cord Kit The user is responsible for connecting the power supply cord to the connection block located behind the back panel access cover This appliance may be connected by means of permanent hard wiring flexible armored or nonmetallic shielded copper cable when local code allow it or by means of a power supply cord kit NOTE Electric Slide in Range is shipped from factory with 1 1 8 2 9 cm dia hole as shown on figure 4 If a larger hole is required punch out the knockout Risk of fire or electrical shock exists if an incorrect size range cord kit is used the Installation Instructions are not followed or the strain relief bracket is discarded For mobile homes new installations or recreational vehicles use only a power supply kit designed for a range at 125V 250V 50A recommended minimum 40A Cor
13. ELECTRIC RANGE INSTALLATION INSTRUCTIONS Three Conductor Wire Connection to Range If local codes permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord see Figure 6 1 Remove the screws from the access plate at the lower right end of the rear cover to expose range terminal connection block 2 Using the nuts supplied in the literature package connect the neutral of the copper power supply cord to the center silver colored terminal of the terminal block and connect the other wires to the outer terminals Match wires and terminals by color red wires connected to the right terminal black wires connected to the left terminal see figure 6 3 Replace the terminal cover and replace the screws Silver Colored Terminal Red Wire Terminal _ _ Block Black Neutral Wire White Wire Grounding Strap 1 1 8 2 9 cm Dia Direct Connection Hole Punch Out A User Supplied Strain relief Must Be Installed at This To 240 V a Location Receptacle Knockout for 1 3 8 3 5 cm Dia Cord Kit Hole Figure 6 Four Conductor Wire Connection to Range Where local codes does NOT permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord see Figure 7 1 Remove the screws from the access plate at the lower right end of the rear cover to expose range terminal connection block 2 Remove the grounding st
14. a arazadera de releva provista debe de estar instalada a esta ubicaci n Hacia el 240 V recept culo NOTA Asegurese de quitar _________ y la banda de puesta a tierra provista Figura 7 INSTRUCCIONES PARA INSTALACI N DE LA ESTUFA EL CTRICA DE 30 Conexi n el ctrica directa al cortacircuito a la caja de fusibles o la caja de empalmes Si el aparato est conectado directamente al cortacircuito a la caja de fusibles o a la caja de empalmes use un cable blindado flexible o no met lico recubierto de cobre con alambre a tierra Provee una abrazadera releva de anclaje hom logo UL a cada extremidad del cable A la extremidad del electrodom stico el cable pase a trav s del agujero de la conexi n directa ver Figura 7 en el cord n de la placa de montaje El tama o de los alambres alambre de cobre solamente y las conexiones deben estar conforme al r gimen del electrodom stico Donde los c digos locales permitan conectar el conductor de puesta a tierra del electrodom stico al neutral blanco vea Figura 8 1 Desconecte el suministro el ctrico 2 Siga las instrucciones en la p gina anterior para la conexi n del alambre de cuatro conductores a la cocina Fig 7 3 En el cortacircuito la caja de fusibles o la caja de empalmes Fig 8 a Conecte el alambre verde o cobre desnudo el alambre blanco del cable del electrodom stico y el alambre neutral blanco juntos b Conecte los dos alambres negros
15. asera de la estufa Siga todos los requerimientos de medidas antes proporcionados para evitar da os a la propiedad peligro de encendidos potenciales o superficies y cortes de gabinetes que sean incorrectos Para eliminar el riesgo de quemaduras o incendio cuando trate de alcanzar objetos por sobre unidades de superficie calentadas debe evitarse que los gabinetes para almacenamiento est n localizados encima de la superficie de la estufa Si existen gabinetes de almacenamiento el riesgo puede ser reducido instalando una campana de estufa que se proyecte en forma horizontal a una distancia m nima de 5 mas all del fondo de los gabinetes Notas importantes para el instalador 1 Lea todas las instrucciones contenidas en este manual antes de instalar la estufa 2 Saque todo el material usado en el embalaje de la estufa antes de conectar el suministro el ctrico a la estufa 3 Observe todos los c digos y reglamentos pertinentes 4 Deje estas instrucciones con el consumidor Impreso en Canada Maximum 36 1 8 o 42 Puerta abre VISTA POSTERIOR I amp S S Sa C QM gt 3 lt S Todas las dimensiones a 4 7 o aS para la ubicaci n del tomacorriente el ctrico son m ximas El ar a del cubo muestra Ubicaci n donde se debe instalar del bloque a el tomacorriente terminal 4 el ctrico para 4 Instalaci n a ras de la
16. d must have either 3 when local code permits grounding through neutral or 4 conductors Terminal on end of wires must be either closed loop or open spade lug with upturned ends Cord must have strain relief clamp If a 50A circuit is used a 50A power cord must be used Do not loosen the nuts which secure the factory installed range wiring to terminal block while connecting range Electrical failure or loss of electrical connection may occur A WARNING Electrical Shock Hazard Electrical ground is required on this appliance Do not connect to the electrical supply until appliance is permanently grounded Disconnect power to the circuit breaker or fuse box before making the electrical connection This appliance must be connected to a grounded metallic permanent wiring system or a grounding connector should be connected to the grounding terminal or wire lead on the appliance Failure to do any of the above could result in a fire personal injury or electrical shock This appliance is manufactured with the frame grounded by connection of a grounding strap between the neutral power supply terminal and the frame If used in USA in a new branch circuit installation 1996 NEC mobile home or recreational vehicule where local code do not permit grounding through neutral white wire or in Canada remove the grounding strap from the frame and cut the other end near the neutral terminal Connect the appliance in usual manner 30
17. de alambre en el compartimiento de la estufa Si se deja exceso de alambre en el compartimiento sta no permitir que la cubierta de acceso sea cerrada en forma apropiada lo cual puede crear un riesgo el ctrico potencial si se perforan los alambres Cuando se use conduit flexible o cable para estufas use un conector flexible o cable de estufa resistente a tensiones NOTA Use solamente alambre de cobre en la conexi n al bloque terminal 5 1 Modelos que requieren Juego de Cord n para el Suministro de Energ a Juego de cord n de 3 alambres El utilizado es responsable de la conexi n del cable del suministro el ctrico al bloque de conexi n situado detr s del panel de acceso El electrodom stico se puede conectar a trav s de un cableado permanente cableado duro cable de cobre blindado armado o cable no met lico flexible cuando el c digo local lo permite o por medio de un kit de cable de alimentaci n Vea la gr fica en la p gina siguiente para encontrar el tama o m nimo del cable a utilizarse el listado general de la UL c digo local puede diferenciar NOTA La cocina corrediza el ctrica viene de fabrica con un agujero de di metro 1 1 8 2 9 cm come se muestra en la figura 4 Si un agujero mas largo est necesario retire la arandela de la pre cortada El riesgo de fuego o de choque el ctrico puede aparecer si usa el tama o de cable incorrecto si las instrucciones de instalaci n no son s
18. eguidas o si retira la abrazadera de releva Para casas sobre ruedas nuevas instalaciones en los veh culos de recreativos o en las lugares donde los c digos locales no permiten la conexi n del conductor de tierra al neutro un ensamble de suministro el ctrico de 4 conductores para estufas calificado a 125 250 voltios m nimo 50 Amperes m nimo debe de ser utilizado ver la figura 5 Si se utiliza un circuito 50A un cable el ctrico 50A debe ser utilizado No desajuste las tuercas que aseguran la conexi n de la cocina al bloque terminal cuando est instal ndola El corte o la perdida de corriente el ctrica puede ocurrir ADVERTENCIA Peligro de choque el ctrico e La conexi n a tierra es requerida para este electrodom stico No conecte al suministro el ctrico hasta que el electrodom stico este conectado a tierra de manera permanente Desconecte el suministro el ctrico hacia la caja de empalmes antes de hacer la conexi n el ctrica Este electrodom stico debe ser conectado a un sistema de alambres permanentes met licos conectados a tierra o una puesta a tierra debe ser conectada al terminal de tierra o un emplomando al electrodom stico El no seguir ninguna de estas instrucciones podr a causar fuego heridas personales o choques el ctricos Este electrodom stico fue fabricado con el marco aterrizado a trav s de una correa de conexi n entre el neutral de la fuente de alimentaci n y el marco Si es uti
19. idad de este o de cualquier otro artefacto 1 Espacios y dimensiones a Proporcione espacios adecuados entre la estufa y las superficies combustibles adyacentes b Ubicacion Examine el lugar en el cual va a ser instalada la estufa Determine la existencia de suministro el ctrico adecuado y la estabilidad del piso c Se deben usar las medidas indicadas Las dimensiones indicadas proporcionan espacio m nimo La superficie de contacto debe ser s lida y estar a nivel VISTA TYPICAL CABINET INSTALLATION FRONTAL 30 Minimum M nimo a los 413 gt M nimo a la 1 gt gabinetes M xima distancia pared a cada lado de 18 sobre cada entre los gabinetes la cocina o la cocina lado dela yla parte superior a 36 de alto estufa de la cocina A ees AO eel 0 clearance below cooking and at rear of range Un m nimo de 30 de espacio entre la parte superior de la superficie para estufa y el fondo no protegido de un gabinete de metal o madera o un m nimo de 24 cuando el fondo de metal o madera del gabinete esta protegido por no menos de 14 de material ret rdente con una hoja de acero de no menos MSG No 28 0 015 de acero inoxidable 0 024 de aluminio o 0 020 de cobre 0 es el espacio m nimo para la parte tr
20. ina es trasladada a otro lugar las fijaciones de anti inclinaci n deben tambi n ser trasladadas y instala das con la cocina Las instrucciones provistas sirven para instalaci n en suelo de madera o concreto Al fijar los tornillos al suelo asegurase que no atraviesen la instalaci n el ctrica o de fontaner a Wa ara Riesgo de volcamiento y e Un ni o o adulto puede volcar la y estufa y acabar muerto e Verifique que se haya instalado el dispositivo antivuelco en el piso o en la pared e Aseg rese de que el dispositivo antivuelco se haya reacoplado cuando mueva la estufa sobre el piso o a la pared e No utilice la estufa sin el dispositivo antivuelco instalado y acoplado e Sino se siguen estas instrucciones se puede provocar la muerte o quemaduras graves en ni os y adultos A Localice la fijaci n usando el papel modelo Localice la posici n de la fijaci n colocando la plantilla sim tricamente a la l nea central de la apertura El soporte antivuelco puede instalarse en el lado izquierdo o derecho en la parte posterior de la estufa Marque la ubicaci n de los agujeros de tornillos come se muestra en el papel Figura 1 B Perforaci n de agujeros piloto y montura de sujeci n Perfore un agujero piloto de 1 8 en el lugar en el que se vayan a instalar los tornillos Si la montura se va a instalar a en la pared practique un agujero piloto con una inclinaci n aproximada de 20 hacia
21. lizado en los E E U U con un circuito nuevo de instalaci n 1996 NEC en casa sobre ruedas o veh culo recreativo donde el c digo local no permite el atterizaje a trav s del cable neutro blanco o en Canad remueva la correa de aterrizaje del marco y corte el otro extremo cerca de la terminal de neutral Conecte el electrodom stico de la forma usual INSTRUCCIONES PARA INSTALACI N DE LA ESTUFA EL CTRICA DE 30 Conexi n del cable a tres alambres la cocina Si los c digos locales permiten la conexi n del conductor a tierra del armaz n al alambre neutral del cable de bronce del suministro el ctrico vea figura 6 1 Retire los tornillos de la parte baja de la cubierta del cable trasero cubierta de acceso para tener acceso al bloque de conexi n del borne terminal 2 Utilizar los tuercas suministraron en el paquete de la literatura para conectar la parte neutral del cable de bronce de suministro el ctrico al terminal plateado que se encuentra al centro del bloque terminal y conectar los otros alambres a los terminales externos Aparee los alambres y los terminales seg n el color alambres rojos conectados al terminal derecho alambres negros conectados al terminal izquierdo vea figura 6 3 Baje la cubierta del terminal y vuelva al colocar los tornillos Terminal plata Le Al am b re i roj O Bloque o Ny E Cord n de terminal 33d Al placa de montaje o A Blanco E SS
22. nd the cable goes through the Direct Connection Hole see Figure 7 on the Cord Mounting Plate Wire sizes copper wire only and connections must conform to the rating of the appliance Where local codes permit connecting the appliance grounding conductor to the neutral white wire see Figure 8 1 Be sure that no power is supplied on the cable from residence 2 Follow instructions on previous page for Four Conductor Wire Connection to Range Fig 7 3 In the circuit breaker fuse box or junction box Fig 8 a Connect the green or bare copper wire the white appliance cable wire and the neutral white wire together b Connect the 2 black wires together c Connect the 2 red wires together Cable from Residence Neutral white Wire Junction Box White Wire Green A U L listed Conduit or Bare Copper Connector or CSA Wire Cable from listed Appliance NOTE Be sure to remove the supplied grounding strap _ gt Figure 8 3 Wire Grounded Neutral Electrical System Example Junction Box Where local codes DO NOT permit connecting the appliance grounding conductor to the neutral white wire or if connecting to 4 wire electrical system see Figure 9 1 Be sure that no power is supplied on the cable from residence 2 Follow instructions on previous page for Four Conductor Wire Connection to Range Fig 7 3 Inthe circuit breaker fuse box or junction box Fig 9
23. ons with your Use and Care Guide for future reference Printed in Canada 318201737 1201 Rev A 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS 2 Tools You Will Need For leveling legs and Anti Tip Bracket N e Adjustable wrench or channel lock pliers _____ e 5 16 Nutdriver or Flat Head Screwdriver e Electric Drill amp 1 8 Diameter Drill Bit Masonry Drill Bit if installing in concrete e Level amp Measuring Tape CAD A fo o ol For electrical supply connection e 1 4 amp 3 8 Socket driver or Nutdriver Additional Materials You Will Need e Power Supply Cord or AS e Copper Electrical Wiring amp Metal ES Conduit for hard wiring 3 Anti tip Bracket Installation Instructions Important Safety Warning To reduce the risk of tipping of the range the range must be secured to the floor by the properly installed anti tip bracket and screws packed with the range Failure to install the anti tip bracket will allow the range to tip over if excessive weight is placed on an open door or if child climbs upon it Serious injury might result from spilled hot liquids or from the range itself If range is ever moved to a different location the anti tip brackets must also be moved and installed with the range Instructions are provided for installation in wood or cement floor When fastening to floor be sure that
24. rap from the terminal block and from the appliance frame 3 Using the nuts supplied with the literature package connect the ground wire green of the copper power supply cord to the frame of the appliance with the ground screw using the hole in the frame where the ground strap was removed see Figure 7 4 Connect the neutral of the copper power supply cord to the center silver colored terminal of the terminal block and connect the other wires to the outer terminals Match wires and terminals by color red wires connected to the right terminal black wires connected to the left terminal 5 Replace the terminal cover and replace the screws Silver Colored Terminal Terminal Block Y yi AL Us E ING GA y I White Wire Black Wire 1 1 8 2 9cm Dia Direct Connection Hole Punch Out Knockout fo 1 3 8 3 5cm Dia Cord Kit Hole Copper Wire A User Supplied Strain relief Must Be Installed at This Location To 240 V Receptacle NOTE Be sure to remove the supplied grounding strap _ gt Figure 7 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS Direct Electrical Connection to the Circuit Breaker Fuse Box or Junction Box If the appliance is connected directly to the circuit breaker fuse box or junction box use flexible armored or nonmetallic sheathed copper cable with grounding wire Supply a U L listed strain relief at each end of the cable At the appliance e