Home

ResortLock RL2000N-S Instructions / Assembly

image

Contents

1. 1 9digitnewmc 1 9digitnew mc 2 To change Master Code and delete all user codes current or default mc 22 1 9 digitnew mc 1 9digitnewme 3 Set date amp time 24 hr clock Example 2 45PM on July 12 2010 1007121445 mc 88 yymmddhhmm 4 Enter one or more User Code with no restriction 5 Enter one or more iButton key with no restriction mc 01 6 Enter one or more iButton key User Code with no restriction 7 Enter one or more User Code with time restriction for multiple codes repeat highlighted beginning time ending time 8 Enter one or more iButton key with time restriction repeat highlic beginning time ending time mc 01 9 Enter one or multiple iButton User Codes with time restriction for multiple repeat highlighted beginning time ending time 10 Enable Passage Mode 1 Monday 7 Sunday _ me 15 1 7Schedule hhmmstart hhmmend 11 Disable Passage Mode mc 16 12 Enable disable LED blink 2 beeps blink off 4 beeps blink on me 18 Warning enabling blink mode will drain batteries more quickly Lock will blink red when locked green when unlocked 13 Enable Daylight Saving Time Lock time does not change when you enable this function The time will change according to the U S Daylight Saving Time schedu
2. LOGASTATE ResortLoGk Installation amp User Manual For use with ResortLock RL2000 and LockState LS 1250 To ae ee Major Lock Parts List Rear Handle Rear Lock housing Screws Rear Housing Battery Plate Screw Battery Plate Rear Rubber Gasket Door Latch Latch Screws Dust Boot Strike Plate Front Lock Fastener Post Square Shaft Front Rubber Gasket Front Lock Housing Position Pin Upper Fastener Post optional Attachment Screw optional iButton Reader Keypad Installation Instructions Step 1 Insert the latch into the latch hole Secure the latch with two screws Accessories Parts List J C Upper Fastener 1 C Battery Plate Screw 3 2 DOD BackCover Screw 2 3 e Screws 4 4 o Square Spindle 1 5 e lt Position Pin 1 6 c lt FastenerExtension 2 Step 2 Insert the square spindle A into the center hub B Then secure the spindle by inserting the position pin C through the hole in the hub amp rite at spindle Bend the ends of the pin around the hub if applicable to secure Step 3 Step 4 Screw in and tighten both fastener Place the front of the lock onto the door extensions D Attach and tighten with the rubber gasket F between the optional upper fastener post E if door and the lock housing Feed the needed Upper post is recommended power cable G through the door hole but not required Ensure
3. maximum security change the default Master Code User code User Codes are the normal codes for day to day operation Service Code Service codes can be used for maintenance personnel or vendors Service codes only grant one time access A total of 10 sets of service codes can be programmed into each lock Passage Mode When Passage Mode is enabled the lock will stay in an unlocked status after a valid entry code is entered Enter a valid entry code to re lock the door Storehouse Mode For each valid entry the lock will automatically re lock after 5 seconds Time Format 24 hr clock 8 30AM 0830 5 30PM 1730 Schedule Date 1 Mon 2 Tue 7 Sun Quick Start Guide Step 1 Program a new Master Code into the lock The Master Code DOES NOT unlock or lock the door It is only used to program your lock The default Master Code is 123456 For security purposes you will need to change this to your own Master Code Decide on a new Master Code and write it here To program a new Master Code enter the following into the lock s keypad 123456 11 Your Master Code Your Master Code Again If done correctly after the last you press you ll hear 2 beeps with 2 green flashes Step 2 Program the Date amp Time Some functions on the lock will not work on the lock unless the date amp time are programmed To program the date amp time enter the following Master Code 88 YYMMDDHHMM Example If the date and time is 05
4. the dot on the hub is facing up before placing on door Extension 1 Latch 1 Dust Boot 1 Step 5 Step 6 Override Key 2 Attach the battery plate on the inside Install 4 AA batteries and plug in the SC4 Cylinder 1 door with the rubber gasket between the power cable G Secure the back lock door and battery plate Feed the power housing onto the battery plate with the plug through the small rectangular hole upper and lower screws Press both on the plate Secure the battery plate to catch pins in and snap the rear handle front lock fastener posts with 2 screws onto drive shaft Press both catch pins Front Handle amp Key Installation 1 Ensure that the key override slot is in the horrizontal position 3 Insert the key into the key cylin der from the front of the handle and turn 90 clockwise 5 Press in both catch pins and snap handle over pins 2 Slide the key cylinder into the back of the handle 4 Slide the handle onto the brass drive shaft until it hits the catch pins 6 Turn key back to the left and remove the key from the key cylinder Lock Operation Guide General Information e Door Handle The handle is reversible so it will fit both right and left handed doors The handle will always turn even when the door is locked However when locked the handle will not retract the latch The interior handle will always retract the latch e Exit Programming Mode Enter
5. to exit programming mode or wait for 10 seconds e Low battery warning When batteries are low the red LED will flash and beep five times after entering a valid User Code e Unlocking indicator Green light will flash and beep twice r e Locking indicator No light and will beep twice L e Reset To reset the lock back to factory default settings press and hold the reset button for 10 seconds until the light on the front of the lock starts flashing green Release the reset button and press the key to confirm You will receive 3 beeps if successful n Reset Button Manufacture Default Setting e Daylight Saving Mode Disabled e Auto Lock Unlock Disabled e Lock Mode Storehouse e Default Programming Master Code 123456 e Test Code 0 Unlocking the Door There are several ways to unlock the lock including the following methods e Keycode Enter a User Code then press iButton Touch the iButton key to the lock reader iButton Keycode Touch the iButton key to the lock reader then enter User Code and press One time service code One time code then press Manual key Insert and turn the override key 90 degrees clockwise then turn the handle Terms Master Code MC The master code enters the lock into programming mode It will not lock or unlock the lock the door If more than 6 seconds pass in between programming entries the lock will return to normal operational status For
6. 30 2010 at 3 32PM you would enter Master Code 88 1005301532 Step 3 Program a User Code into the lock Important Your lock will not lock until a valid User Code is programmed and used on the lock User Codes are the codes you will use to unlock and lock your door These codes will remain active in the lock until they are deleted if desired Up to 800 permanent codes can be programmed into the lock Here is how Master Code 01 1 9 digit user code If done correctly you will hear two beeps after pressing the 3 then a red light after the 4 Step 4 Set the Passage Mode Optional Your lock is shipped in Storehouse Mode This means the lock will re lock 5 seconds after it is unlocked To change this to passage mode enter the following Master Code 15 1 7 Schedule hhmm start hhmm end Example If you want the lock to always be in Passage Mode enter Master Code 15 1234567 0001 2359 7 days of the week from 12 01AM to 11 59PM Step 5 Enable Daylight Saving Time If you live in an area that observes Daylight Saving Time you will want to enable this function Enabling does not change the current time on the lock The time wil change according to the U S Daylight Saving Time schedule To enable enter Master Code 31 Complete List of Manual Programming Functions 1 To seta new or change the Master Code and not delete existing user codes current or default mc 11
7. le 14 Disable Daylight Saving Time 15 Add One Time Service codes up to 10 16 Delete one User Code or iButton user me 46 17 Enable Auto UNlock function mc 64 Disable Auto UNlock function 19 Set Automatic Unlock time Enable function 17 first 20 Enable Auto Lock function mc 67 Disable Auto Lock function 22 Set Automatic Lock time Enable function 20 first 23 Enable Disable temporary lockout of all users go Advanced Schedule Access for multiple users repeat highlighted 24 Set schedule for User Code 1 Monday 7 Sunday me 45 For Example to set schedule from 8 00AM to 5 00PM Mon to A User Code or iButton must be programmed before Advanced Schedule Access can be applied

Download Pdf Manuals