Home

SPEEDWAY 8465 Use and Care Manual

image

Contents

1. may result in serious injury Al adjustments or repairs must be done with the compressor disconnected from the power source SAFETY INSTRUCTIONS POWER SUPPLY Your compressor must be connected to 120V outlet using 15 amp delay fuse or circuit breaker Failure to connect in this way can result in injury from shock or properly grounded Not all outlets are properly grounded If you have hesitations on whether or not your outlet is properly grounded have it checked bya qualified electrician WARNING If not properly grounded this compressor can cause electrical shock particularly when used In damp locations it the power cord Is worn or damaged in any way have It replaced immediately If the compressor should breakdown the grounding provides path of least resistance for the electric current which reduces the risk of electric shock The plug must be plugged into an appropriate outlet that is grounded in accordance with the local codes and ordinances WARNING To maintain proper grounding do not alter the grounding prong in any manner For warranty purchases plea keep your dated proof of purchase le or atiach to the manual for safekeeping For customer service 1 800 348 5004 or ema feedbackGnatiiools com 8808582 07 10 120V OPERATION As received from the factory your compressor Is ready to run for 120V operation This m
2. provide the following information Address ary correspondence 10 poe North American Tool Industries Part description and number as shown in parts list he Serial number if any Huntington IN 48750 Moor Cover 1 1 2 5 22 Washer w 21 22 1 23 Seg Washer Guage 1 Hex Na 2 Ostet Presse A Mororen A a 2 15 1 Ernst Poe Pressure 1 g Satay Vave Power amp Fremen Erter 22123 z 9 7 Dran vane Teednackgnatitoois com 1 300 348 5004
3. release valve does not work properly over pressurization may occur causing air tank to rupture or explode Pull the ring on the safety valve daily to make sure that the safety valve operates freely If the valve Is stuck or does not operate smoothly it must be replaced with the same type of valve SETTING UP YOUR AIR COMPRESSOR Operate the air compressor in dry clean and well ventilated area Clean off dust or dir that collects on the air compressor air compressor runs cooler and provides longer senice The ventilation openings on your air compressor are necessary to maintain proper operating temperature Do not place rags or other containers near these openings ADDITIONAL REGULATORS AND CONTROLS since the air tank pressure is usually greater than that which is needed a regulator is employed control me air pressure ahead ofany driven device Separate air transformers which combine the function of ait regulation moisture and dirt removal should be used where applicable PREPARATION FOR USE 1 Before attaching the air hose or accessories make sure the switch Is setto OFF and the alr regulator is closed completely tumed counterclockwise 2 Attach the 14n female fiting AFig 7 to one end of the hose B then connect the female fiting A into the quick connect outlet at the back of the compressor then attach
4. the female quick connect D to other end of the hose Atach optional air tool or supplied accessories To prevent air leaks itis recommended to install Teflon Tape not supplied on the threads at both ends of the hose 5 Tum the switch to the position and allow tank pressure to build Motor will stop when tank pressure reaches cut out pressure 8 Open the regulator by turning itclockwise Adjust the regulator to the correct pressure setting The compressor is ready WARNING Too much alr pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating of the tool being used AFTER USE 1 Set the switch to 2 the regulator counterclockwise to set the outlet pressure to zero 3 Disconnect the air tool or accessory 4 Pull ring on safety valve A Fig 6 allowing air to bleed from the tank until tank pressure is approxmately 20 PSI Release safety valve ring 5 Drain water from air tank Turn drain valve A Fig 5 counterclockwise to open WARNING Water will condense in the air tank The water will corrode and weaken the air tank causing risk of air tank rupture is not drained properly NOTE if drain valve is plugged ring on safety valve A Fig 6 a
5. Please carefully read and save these instructions before attempting to assemble maintain install or operate this product Observe all safety information to protect yourself and others Failure to observe the instructions may in property damage andor personal injury Please keep instructions for future reference Important Operating instruction 2 GALLON TWIN STACK Models 8682 8465 9357 AIR COMPRESSOR CALIFORNIA PROPOSITIONS SPECIFICATIONS GROUNDING WARNING You can create dust Type Twin Stack Ol free Your compressor must be when you cut sand drill or grind materials such as wood paint metal concrete cement or other masonry This dust often contains chemicals known to cause cancer birth defects or other reproductive harm Wear protective gear WARNING This product or its power cord may contain chemicals including lead known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling CAUTION FOR YOUR OWN SAFETY READ INSTRUCTION MANUAL COMPLETELY AND CAREFULLY BEFORE OPERATING THIS OIL FREE AIR COMPRESSOR KIT CFM 1 1 40 PSI Horsepower 1 2 Maximum PSI 100 GENERAL SAFETY WARNING Please read and understand all instructions Failure to follow all instructions listed below may result in electric shock fire and or serious personal injury Failure to comply with all electrical specifications
6. achine is intended for use circuit that has an outlet and plug which looks like the illustrated In Fig 1 WARNING Do not use two prong adapter 8 EXTENSION CORDS The use of any extension cord will cau loss of power Itis recommended to use longer air hose instead of an extension cord Use the on below to determine the minimum wire size extension cord Use only 3 wire extension cords which have 3 prong grounding type plugs and 3 hole receptacles which accept the tool s plug For circuits that are further away from the electrical circuit box the wire size must be increased proportionately in order to deliver ample voltage to the motor Refer to Fig 2 for wire length and size POURED OPERATION CONTROLS CHECK VALVE When the compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches Cut Our pressure the check vale closes allowing ai pressure to remain inside the air tank ONOFF SWITCH A IG 3 Tum this switch ON press downwards to provide power to the automatic pressure switch Id OFF to remove power at the end of each use PRESSURE SWITCH The pressure switch automatically starts the motor when the tank pressure drops below the factory set Cut in pressure Italso stops the motor when the air tank pressure reac
7. connections Chock valvo by puling upwards on ring vave leasing TeodBack matiiosis com 1 300 348 5004 Limited Manufacturer Warranty North American Too NAT industries makes every effort to ensure that this product meets high quality and durability standards NAT warrants to the original retail consumer a 1 year limited warranty from the date the product was purchased at retail and each product is free from defects in materials Warranty does not apply to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations lack of maintenance NAT shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To receive service under warranty the original manufacturer part must be returned for examination by an authorized service center Shipping and handling charges may apply defect is found NAT will either repair or replace the product at its discretion DO NOT RETURN TO STORE For Customer Service Email feedback natitools com or Call 1 800 348 5004 TeodBack atiiosis com 1 300 348 5004 amp 2 GALLON TWIN STACK AIR COMPRESSOR Models 8682 8465 9357 For customer service 1 800 348 5004 or ema feedbackGnatiiools com P 8908682 07 10 ris List Call 1 800 348 5004 for assistance or replacement parts Proaso
8. hes the factory set Cut Out pressure an REGULATOR A FIG 4 The air pressure coming from the air tank Is controlled by the regulator Tum the regulator knob clockwise to increase pressure and counterclockwise to decrease pressure To avoid minor readjustment after making change in the pressure setting always approach the desired pressure from a lower pressure When reducing from higher to lower setting first reduce the pressure less than that desired then bring It up to the desired pressure Depending on the air requirements of each particular accessory the outlet regulated air pressure may have to be adjusted while operating the accessory OUTLET PRESSURE GUAGE AG 4 The tank pressure gauge Indicates the reserve air pressure In the tank TANK PRESSURE GAUGE AGS Indicates the available reserve alr pressure in the tank DRAIN VALVE A FIGS The drain valve is located on the base of the air tank and is used to drain condensation at the end of each use feedbackgmatioals com 4 800 348 5004 SAFETY PRESSURE RELEASE VALVE A FIG 6 If the pressure switch does not shutoff the air compressor at its cutout pressure setting and the alr pressure keeps rising the safety valve will protect against high pressure by popping out above factory set pressure slightly higher than the pressure switch cut out setting WARNING If the safety pressure
9. nd hold until all air pressure has been released The drain valve can feedbackgmatioals com 3 4 800 348 5004 then be removed cleaned and reinstalled 5 After the water has been completely drained turn the drain valve to close The air compressor can now be stored MAINTENANCE Before doing any maintenance or adjustments to your air compressor the following safety precautions should be taken Disconnect electrical power Release air tank pressure DAILY OR BEFORE EACH USE 1 Drain condensation from tank 2 Check for unusual noise or Vibration 3 Be sure all nuts and bolts are tight KEEP TOOL CLEAN passages with dry compressed air Clean all plastic parts with soft damp cloth NEVER use to clean plastic parts This could possibly dissolve or otherwise damage the material CAUTION Wear safety glasses while using compressed air FAILURE TO START Should your compressor fail to start check to make sure the prongs on the cord plug are making good contact with the outlet check compressor fuse or tripped circuit breakers in the line REPLACEMENT PARTS For servicing contact North American Tool Please use the 10 digit part numbers listed in this manual for all part orders where applicable feedbackgmatioals com 1 300 348 5004 Troubleshooting Guide Corrective Action Symptom Possible Cause s Check wing