Home

Lux WIN100-005 Use and Care Manual

image

Contents

1. SENSOR e Heating and Cooling Electronic Programmable Plugs into normal 110 Separate Programs for Heating and Cooling Armchair Programming e Easy Programming with Volt 15 Amp Electrical LUX Speed Dial Patent Outlet 5 673 850 e 5 2 Day Programming Battery Free Nonvolatile Weekdays and Weekends Memory For All Programs And Settings e ETL Approved e User Calibration On Screen Low Bal can be different Energy Star Compliant e Default Energy Star Approved Program ery Positive On Off Switch Indicator e Easy to Install e F C Temperature 4 Periods Per Day Display Soft Touch Buttons e 2 Minute Short Cyc 120VAC Powered with Batteries e 2 G13A size 1 5V Protection Alkaline Button Cell e Adjustable Temperature Batteries Included For differential Cycle Rate 1 Clock Only thru 9 Temporary and e 1 Year Warranty Constant Temperature Override ELECTRICAL RATINGS 120V 60 Hz e Maximum load is 15 Amps at 120 Volts Power Consumption 2 W maximum Plug and Receptacle NEMA 5 15R normal household 15 Amp receptacle WARNINGS Read all instructions before using this thermostat To reduce the risk of electric shock this product has a grounding type plug that has a third grounding pin This pin will only fit into a grounding type power outlet If the plug does not fit into the outlet contact a qualified electrician to install the proper outlet Do n
2. www luxproducts com Our web site offers you i another To change this offset from its default value of answers to the most common technical questions and 1 Open the door on the front of the thermostat OA AeA ba ihe en e our 2 Rotate the dial to SET DAY TIME 3 Simultaneously press NEXT and HOLD The Temperature Offset value will flash gt Z Limited Warranty If this unit fails because of defects in materials or workmanship within three years of date of original purchase LUX Products Corporation will at its option repair or replace it This warranty does not cover damage by accident misuse or failure to follow installation instructions Implied warranties are limited in duration to three years from date of original purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation i may not apply to you Please return malfunctioning or remain untouched i fective units to the participating retailer from which 5 Use the UP DOWN keys to adjust the offset value purchase was made along with proof of purchase 6 Return the dial to its RUN position to accept the new Please refer to TECHNICAL ASSISTANCE before value returning thermostat Purchaser assumes all risks and SOFTWARE RESET liability for incidental and consequential damage Use this feature to make all settings and programs brea mom naain an uss H no anin return to their default values Press and release RESET States
3. 00 NO A DW Hie GXCUSION Or INGICENLA Or button using a pen or pencil It will perform a system Consequential damages so the above exclusion may check and then returns all settings to their original not apply to you This warranty gives you specific legal initiati i rights and you may also have other rights which vary default values before initiating normal operation from state to state Applicable in the U S A only 4 The default value is 0 and in most cases should Q D TEMP TIME COPYRIGHT 2006 LUX PRODUCTS CORPORATION ALL RIGHTS RESERVED
4. the programmed set temperature e Changing system mode or rotating the SPEED DIAL will also cancel a HOLD TEMPERATURE OVERRIDE OVERRIDE allows you to change the current SET TEMPERATURE in HEAT of COOL until the next program temperature programs and setup values into the period without changing your temperature control programs Press an arrow key once While the Set Temperature is flashing press an UP or DOWN key to adjust the set temperature by one degree in the associated direction Holding the key will automatically advance the setting in the associated direction The OVERRIDE will be canceled at the start of the next program period and the temperature setting will return to its programmed value An OVERRIDE may be terminated by rotating the dial times per hour A smaller swing number increases the switching the mode to OFF or initiating a Hold e Adjusting the set temperature to its program value will constant A larger swing number decreases the also cancel an OVERRIDE PROGRAMMING EDITING HEAT OR COOL PROGRAMS Le ON SET WEEKEND RESET PROGRAMS HOLD TDAY ID TIME RUN NOTE Pressing this button will overwrite your program and install the default values of all unit s nonvolatile memory To ease reprogramming later record your thermostat s programs and settings in the table provided at the page bottom before using this button TEMPERATURE VARIATION SWING Your thermostat wo
5. Complete Easy To Read INSTALLATION AND OPERATING INSTRUCTIONS WIN100 SERIES SMART TEMP ELECTRONIC THERMOSTAT LUX PRODUCTS CORPORATION 52020 Mt Laurel New Jersey 08054 USA IMPORTANT Please read all instructions carefully before beginning installation Save them for future reference WARNING FOR USE ONLY WITH AIR CONDITIONERS AND SPACE HEATERS THAT AUTOMATICALLY RESTART COOLING OR HEATING OPERATION AFTER POWER RECONNECTION Thank you for your confidence in our product To obtain the best results from your investment please read these instructions and acquaint yourself with your purchase before installing your new thermostat Then follow the installation procedures one step at a time This will save you time and minimize the chance of damaging the thermostat and the systems it controls These instructions may contain information beyond that required for your particular installation Please save for future reference COMPATIBILITY Your WIN100 Programmable Outlet Thermostat is compatible with 120Volt 15 Amp Plug 60 Hz Window Air Conditioning Units and Portable Space Heaters only It cannot be used with typical 24 V systems hydronics systems or heat pumps Ask your dealer for other LUX thermostats to control those systems FEATURES aN D 1 ON OFF SWITCH 4 HEAT COOL SWITCH 2 SOFT TOUCH BUTTONS 5 EXTERNAL TEMPERATURE 3 LUX SPEED DIAL
6. ION Do not locate where air circulation is poor such as in a corner or an alcove or behind an open door Do not install it where there are unusual heating conditions such as in direct sunight near a lamp television radiator register or fireplace near hot water pipes in a wall near a stove on the other side of the wall Do not locate in unusual cooling conditions such as on a wall separating an unheated room or in a draft from a stairwell door or window Do not locate in a damp area This can lead to corrosion that will shorten thermostat life Do not install the unit until all construction work and painting has been completed PREPARING THE UNIT 1 The WIN100 comes with 2 G13A size 1 5V Alkaline Button Cell Batteries already installed These batteries power the clock only during normal operation They also rovide backup power to retain the thermostats programs and settings while it is not plugged into the wall In order to activate them you must remove the black ribbon from between the two batteries prior to using it Use a small regular screwdriver to pry open the battery holder and pull out the black ribbon EXTERNAL TEMPERATURE SENSOR F SCREWDRIVER ap 2 When you have the black ribbon out simply push the battery compartment back in while lining up the arrows 3 On the back of the WIN100 there is an External Temperature Sensor that looks like an antenna Pull this sensor out of
7. ing mene CiSpay 8 Weekday Nite Set Temperature BATTERY INSTALLATION 1 Remove fresh batteries from their carton 2 Remove the thermostat from the electrical outlet 3 Use a small regular screwdriver to remove the battery cartridge from the back of the thermostat Use the small regular screwdriver to remove the 2 batteries from the holder 9 and so on until Fri Nite is fully programmed al which point pressing NEXT again will begin the list ai Mo Fri Morn Start Time Use the UP DOWN keys to change the start time for his period Press UP DOWN buttons to change the ime in 15 minute increments Hold UP DOWN button o change the time at a faster rate One period ends at the start time of the next period The end of one period may not be any closer to the beginning of the next period than one 15 minute increment Moving a start time too close to the next start time results in the latter time being pushed ahead oo Press NEXT to accept the displayed start time and advance to the SET TEMPERATURE it will flash to show hat it may be edited The SET TEMPERATURE will be displayed on the right side of the display with the HEAT or COOL indicator visible depending on which mode you have it in Edit the SET TEMPERATURE then press NEXT to accept and advance to the next period When all the periods for the weekdays have been set the start time for the next weekday Morning period will be displayed to begin editing the settings for
8. its clip and bend the wire so that it point straight up This is required for accurate temperature control 4 On the upper right side of the unit there is an On Off switch Place this switch in the OFF position for right now BATTERY PANEL RIBBON EXTERNAL TEMPERATURE SENSOR ON OFF SWITCH MOUNTING WARNING e f any plugs do not fit into the receptacle that you are trying to plug into Stop the WIN100 is not designed for this application e f the cord you are plugging into the WIN100 only has 2 prongs STOP not having a ground wire is unsafe Your Window Air Conditioner or Spacer EOD Heater must have a plug with 3 prongs on it 5 Plug the WIN100 straight into a 110 Volt electrical outlet on the wall nearest your Air Conditioning Unit or Space Heater 6 Plug in the electrical cord from your Window Air Conditioner or Space Heater directly into the front of the WIN100 COMPLETING YOUR INSTALLATION 7 Configure your thermostat at this time Refer to OPERATING INSTRUCTIONS 8 Turn the ON OFF switch on the upper right side to the ON position 9 Turn on your Air Conditioner or Space Heater and turn the thermostat all the way up This will allow the WIN100 to control the room temperature and maintain a specific temperature 10 Verify that the Window Air Conditioner or Space Heater and its fan are operating properly When set to a high temperature the heating system should provide warm air after a sh
9. maximum comfort setting narrow control Day 8 00 AM 62 F 17 C 8 00 AM 85 F 30 C 9 is the maximum energy savings setting wide control Evening 6 00 PM 70 F 21 C 6 00 PM 78 F 26 C 5 Press NEXT Night 10 00 PM 62 F 17 C 10 00 PM 82 F 28 C s 10 EEO TEMPERATURE DISPLAY FORMAT This feature allows you to display temperature in WEEKDAY PROGRAMMING 4 a either degrees C or degrees F To toggle the display mode from Fahrenheit to Celsius or vice versa press and release NEXT and HOLD simultaneously in lt SET WEEKDAY PROGRAMS position BATTERIES MAINTENANCE The WIN100 comes with 2 G13A size 1 5V Alkaline Button Cell Batteries During normal use these To change the HEAT or COOL program Set to HEAT if you are using a Space heater e Set to COOL if you are using a Window Air Conditioner Rotate dial to SET WEEKDAY PROGRAMS MORN Mo Tu We Th Fr will be displayed with the Start Time flashing Programming is performed in the following order 1 Weekday Morn Start Time 2 Weekday Morn Set Temperature batteries are used for the clock only However they 3 Weekday Day Start Time also serve as backup power to retain your programs 4 Weekday Day Set Temperature and settings if you unplug it from the wall These 2 5 Weekday Eve Start Time batteries will need to be changed once every year The 6 Weekday Eve Set Temperature peters oe ibe i batteries are low by 7 Weekday Nite Start Time spiay
10. n a unit has first been powered up with the dial in the RUN position your thermostat will begin to control your heating and or air conditioning system according to it s default ENERGY STAR approved program There is a 2 position slide switch to change temperature control modes Slide the switch to the mode you would like to use HEAT e Use HEAT mode to warm your home with a Space Heater e In HEAT mode HEAT is displayed right of the set emperature COOL Use COOL mode to control your Window Air Conditioner cooling your home In COOL mode COOL is displayed right of the set emperature ON OFF SWITCH Slide the SLIDE switch to OFF when no heating or cooling is desired Heating and cooling will be disabled even though the set temperature room temperature and ime will still be in the display DEFAULT PROGRAM As supplied from the factory your thermostat will use its default ENERGY STAR approved program for emperature control This program and all other settings may be restored to their default values via a SOFTWARE RESET Please refer to DEFAULT TEMPERATURE PROGRAM for program times and temperatures day flash Time to Set HOLD Hold is the simplest method to maintain fixed set temperatures e Press HOLD once to enter the temperature HOLD while in RUN or OVERRIDE HOLD will be displayed on EEKDAY the bottom of the display e Pressing this button again will toggle HOLD off and return the unit to RUN and
11. ort time Likewise a cooling system should provide cool air after a short time Usually sound can be heard while they are running The rush of moving air should be heard within a short time after either has been started 11 Your installation is now complete OPERATING BASICS RUN MODE For the thermostat to function the dial on the face of the thermostat must be turned to the RUN position If you forget to do this it will not work and the door will not close all the way UP DOWN CHANGE KEYS These are the two upper keys just right of the unit s display They are used to adjust set temperatures and make other setting changes Pressing these keys once will adjust a setting one step in the associated direction e f there are many choices for a value usually that setting will advance while holding one of these keys Some settings though must be changed one press at a time SET DAY AND TIME To set the correct time after the unit has lost power or after reset 1 Open the door on the front of the thermostat by lifting up the bottom of the door 2 Rotate the dial to SET DAY AND TIME The abbreviation for the day of week will flash 3 Use the UP key to advance to the curren 4 Press NEXT to adjust the time Time will 5 Use the UP DOWN keys to set the time 6 Pressing NEXT again will toggle from Set Day or vice versa 7 Return the dial to its RUN position TEMPERATURE CONTROL MODES Whe
12. ot change the plug in any way Do not use Outdoors Do not use in a bathroom Never locate where it may fall into a bathtub or other water container Do not insert or allow foreign objects to enter any openings as this may cause electric shock fire or damage to the thermostat Do not use in areas where gasoline paint flammable liquids are used or stored Space Heaters can be dangerous if used improperly Be sure to follow all the Warnings and Cautions that came with the instruction manual written by the manufacturer of the Space Heater Avoid the use of an extension cord because the extension cord may overheat and cause risk of fire However if you have to use an extension cord the cord should be a 3 wire grounding type with No 14 AWG minimum size and rated not less than 1875 Watts Use this thermostat only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons Never clean this thermostat while it is plugged in Turn On Off switch to Off pull out of the wall and then clean by using a rag only CAUTIONS e Your thermostat is protected against normal static electric discharges To minimize the risk of damaging the unit in extremely dry weather touch a grounded metal object before touching your thermostat Be careful not to drop the unit or disturb electronic parts INSTALLATION TOOLS REQUIRED Small regular screwdriver LOCAT
13. rks by turning your heating or cooling system on and off whenever the room temperature varies a certain number of degrees from the set point temperature This variation is the swing Your system should cycle on about 3 to 6 number of cycles so room temperature is more number of cycles saving energy in most cases SWING ADJUSTMENT This setting controls when the heating or cooling turns on and off The Swing setting sets the temperature variation the system allows above or below the set temperature The WIN100 provides two separate programs one for before turning on the heating or Cooling To change heating and the other for cooling Each program has this value separate settings for weekdays and weekends Every 1 Rotate the SPEED DIAL to RUN day a program cycles through four independent periods 2 Press NEXT and HOLD simultaneously The You can use the default programs or alter them to suit Temperature section of the display shows a single digit your schedule number between 1 and 9 DEFAULT TEMPERATURE PROGRAM As supplied from the factory the following ENERGY STAR approved program will be used for temperature control in RUN MODE This program and all other software settings may be restored to their default values Ij via a SOFTWARE RESET PERIOD HEAT MODE COOL MODE 3 Select one of the 9 values the UP DOWN buttons Morning 6 00 AM 70 F 21 C 6 00 AM 78 F 26 C 4 1 is the
14. that day Complete programming for all weekdays and rotate the dial back to RUN to accept all current values and end the programming session WEEKEND PROGRAMMING Weekend programming is identical to weekday programming except that you must rotate the dial to SET WEEKEND PROGRAMS and the days that you will program are Sa and Su together This two day program will repeat ie 4 Remove the used batteries if present and replace them within 90 seconds to avoid having to reset the day and time 5 Install two new G13A size 1 5V Alkaline Button Cell Batteries batteries Observe the polarity marking pictures shown on the battery cartridge 6 Push the battery compartment back into the WIN100 while lining up the arrows 7 Plug the thermostat back into the wall TECHNICAL ASSISTANCE If you have any problems installing or using this ADVANC E D F E ATU RES hermostat please carefully and thoroughly review the instruction manual If you require assistance please contact our Technical Assistance Department at 856 CALIBRATION OFFSET f 234 8803 during regular business hours between Your thermostat is accurately calibrated at the factory 8 00AM and 4 30PM Eastern Standard Time Monday to within 1 F An offset value up to 5 F may be hrough Friday You can also receive technical added to the temperature value that the thermostat assistance online anytime day or night at measures This may allow you to match this thermostat http