Home

Honeywell RTH2510B Use and Care Manual

image

Contents

1. Cool On or Heat is flashing e Heat On is not displayed Cool On is not displayed 69 2725ES A indd 21 Make sure heating and cooling temperatures are set to acceptable ranges Heat 40 to 90 F 4 5 to 32 C Cool 50 to 99 F 10 to 37 C Compressor protection feature is engaged Wait 5 minutes for the system to restart safely without damage to the compressor see page 15 Set the System switch to Heat and set the temperature level above the current room temperature see page 7 Set the System switch to Cool and set the temperature level below the current room temperature see page 7 21 69 2725 5 02 d 5 4 12 11 03 am e Operating Manual 1 year limited warranty Honeywell warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and service for a period of one 1 year from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Honeywell shall repair or replace it at Honeywell s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii call Honeywell Customer Care at 1 800 468 1502 Customer Care will make the determination whether the product should be returned to the following address Honeywell Return Goods Dock 4 MN10 38
2. Appendices Battery 18 Customer assistance 19 In case of difficulty Limited warranty This thermostat is ready to go Your new thermostat is pre programmed and ready to go See page 10 to check settings 69 2725 5 02 5 4 12 11 03 AM Operating Manual About your new thermostat Your new Honeywell thermostat has been designed to give you many years of reliable service and easy to use push button climate control Features e Backlit display is easy to read e Displays ambient measured temperature at all times One touch access to setpoint temperature e Preset program settings e Temporary and permanent override of schedule e Early start ensures the right temperature at the right time e Built in compressor protection 69 2725 5 02 2 69 2725ES 2 5 4 12 11 03 an e RTH2510 RTH2410 This thermostat is ready to go Your new thermostat is pre programmed and ready to go All you have to do is set the time and day Then check the settings below and change if needed 1 2 d 4 Set time and day required for proper operation See page 6 Select system setting Preset to To change see page 7 Select fan setting Preset to To change see page 8 Program schedules
3. Caracter sticas del termostato 2 Cambio del filto eine El termostato est preconfigurado y listo para Ap ndices R pida referencia de los controles Reemplazo de bateria 18 R pida referencia de la pantalla Asistencia al cliente 19 Programaci n y funcionamiento En caso de inconvenientes 20 21 Configuraci n de la hora y el dia 6 Garant a limitada 22 Seleccione la configuraci n del sistema 7 Seleccione la configuraci n del ventilador 8 Este termostato est listo para Utilizaci n de los cronogramas del prograMa isisisi 9 10 Ajuste el cronograma del programa REA SS T0 acci stesse cor i ecrit 11 Ajuste el cronograma del programa RTH 2490 coccion ati 12 Anulaciones del cronograma del proglama o coit ria aaa Protecci n del compresor 69 2725ES A indd 1 funcionar Su nuevo termostato est preprogramado y listo para funcionar Vea la p gina 10 para revisar las configuraciones 69 2725ES 02 5 412 11 03 am e Manual de funcionamiento Acerca de su nuevo termostato Su nuevo termostato Honeywell ha sido disefiado para brindarle muchos afios de funcio namiento confiable y para brindarle un control climatico facil de usar y con s lo apretar un bot n Caracter
4. Preset to energy saving levels while you re at work or asleep To change see pages 9 12 ONE TOUCH TEMP CONTROL You can override the program schedule at any time and manually adjust the temperature see pages 13 14 3 69 2725ES 02 69 2725ES_A indd 3 5 4 12 11 03 u e Operating Manual Quick reference to controls Set Press to set time Screen Lit for 12 seconds when you press any button day schedule Hold Press to override programmed tempera ture control Temperature adjustment see Run Press to resume page 13 14 program schedule a M33612 System switch see page 7 Fan Switch see page 8 Heat Heating system control On Fan runs continuously Off All systems off Auto Fan runs only when heating or cooling system e Cool Cooling system control is on 69 2725 5 02 4 69 2725ES_A indd 4 5 4 12 11 03 an e RTH2510 RTH2410 Quick reference to display screen Setpoint indicator Low battery warning Appears when the E see page 18 setpoint temperature is displayed MN J Current day time EE i 3L E Temperature see page 6 3 L The ambient measured temperature is normally 0 o Batt Current program period Wake io displayed To view the Wake Leave Return Sleep setpoint temperature see pages 9 10 M32701 press the Up or Down button once The setpoint temperature will appear for five seconds System status
5. Presione A o W para ajustar inmediatamente la temperatura Esto anular temporalmente la configuraci n de la temperatura para el per odo actual La palabra Temporary temporalmente aparecer en la pantalla La nueva temperatura se mantendr solamente hasta que comience el pr ximo per odo programado vea la p gina 9 Para cancelar la configuraci n temporal en cualquier momento presione RUN 69 2725ES 02 5 412 11 03 am Manual de funcionamiento e Anulacion del cronograma del programa permanente Presione para ajustar permanentemente la temperatura set O e 6 30 alal mo 10 Run M33604 Presione para anular la configuraci n Hold y volver al cronograma del programa set O 2 Hold 630 710 E Presione HOLD para ajustar permanentemente la temperatura Esto anular las configuraciones de la temperatura para todos los periodos La funci n Hold el cronograma del programa y le permite ajustar el termostato manualmente seg n sea necesario Cualquiera que sea la temperatura que configure sta se mantendr las 24 horas del d a hasta que la cambie manualmente o presione RUN para anular Hold y retomar el cronograma Nota Aseg rese de que el termostato este Configurado con el sistema que usted quiere controlar calor frio 69 2725 5 02 69 2725ES_A indd 14 14 e 5 412 11 03 am e RTH2510 RTH2410 Pr
6. Set Indica normalmente la Hora y dia actuales mE au am temperatura ambiente vea la pagina 6 medida Para ver la Periodo de la E gt temperatura del punto de programaci n actual Wake Heat ajuste presione el bot n Wake Leave Return Sleep On Arriba Abajo una vez La 27 que se despierta m32701 temperatura del punto de se va de su casa regresa y se ajuste aparecer durante 5 duerme vea las paginas 9 a 10 segundos Estado del sistema Cool on fr o encendido El sistema de refrigeraci n est encendido Heat on calor encendido El sistema de calefacci n est encendido Aux On est activada la calefacci n auxiliar Cuando Heat On o Cool On parpadean la protecci n del compresor est activada ver la p gina 15 5 69 2725ES 02 69 2725ES_A indd 5 5 4 12 11 03 u Manual de funcionamiento Configuraci n de la hora y el dia Presione SET luego ajuste la hora 1 Presione el bot n SET luego presione A o Y para configurar la hora del Set Time reloj Set fr xs GA 20 2 Presione el bot n SET luego presione EA o Y para seleccionar el d a de la D semana e m33598 3 Presione RUN para guardar y salir Presione SET y luego seleccione el d a actual Nota Si el reloj destella el termostato seguir sus configuraciones para el per odo Wake Sdi By despertar del lunes hasta que vuelva
7. you want to control heat or cool 69 2725 5 02 69 2725ES_A indd 14 14 e Press HOLD to permanently adjust the temperature This will override the temperature settings for all time periods The Hold feature turns off the program schedule and allows you to adjust the thermostat manually as needed amp Whatever temperature you set will be maintained 24 hours a day until you manually change it or press RUN to cancel Hold and resume the program schedule 5 4 12 11 03 AM e RTH2510 RTH2410 Built in compressor protection a a b30 TE We M32711 Message flashes until safe restart time has elapsed 69 2725ES A indd 15 This feature helps prevent damage to the com pressor in your air conditioning or heat pump system Damage can occur if the compressor is restarted too soon after shutdown This feature forces the compressor to wait 5 minutes before restarting During the wait time the display will flash the message Cool On or Heat On if you have a heat pump When the safe wait time has elapsed the message stops flashing and the compressor turns on 15 69 2725ES 02 d 5 4 12 11 03 am Operating Manual Early Start E J em pa LI i L We m Wake cal M32712 69 2725 5 02 69 2725ES_A indd 16 Early Start This feature allows the heating or cooling to turn on before the program start time so the temperature is rea
8. M32707 bater as 69 2725ES 02 18 9969929299 69 2725ES_A indd 18 d 5 4 12 11 03 am e RTH2510 RTH2410 Asistencia al cliente Hale de la parte inferior para quitar el termostato de la placa para pared Gire el termostato para ver el numero de modelo y el c digo de fecha Para obtener asistencia relacionada con este producto visite http yourhome honeywell com O comun quese con el numero gratuito del servicio de atenci n al cliente llamando al 1 800 468 1502 Para ahorrar tiempo anote el n mero de modelo y el c digo de fecha antes de llamar M33592 RTO 2444 49 42 2 4 69 2725ES_A indd 19 32707 19 69 2725 5 02 5 4 12 11 03 AM Manual de funcionamiento En caso de inconvenientes Si tiene dificultades con el termostato intente seguir las sugerencias que se indican a continuaci n La mayor a de los problemas pueden corregirse r pida y f cilmente La pantalla est vac a El sistema de calefacci n o refrigeraci n no responde 69 2725ES 02 69 2725ES A indd 20 Asegurese de que la puerta del sistema de calefacci n est bien cerrada Asegurese de que las bater as AAA alcalinas est n instaladas correctamente vea la p gina 18 Mueva el interruptor System hasta la posici n Heat vea la p gina 7 Asegurese de que la temperatura sea m s alta que la temperatura in
9. W to set the temperature for this time period then press SET 4 Set time and temperature for the next time period Leave Repeat steps 2 and 3 for each weekday time period 5 Press SET to set weekend time periods Sa amp Su then press RUN to save amp exit m Note Make sure the thermostat is set to the system you want to program Heat or Cool 12 d 5 4 12 11 03 AM RTH2510 RTH2410 Program schedule override temporary Press to temporarily adjust temperature Press A or W to immediately adjust the temperature This will temporarily override A 5 30 the temperature setting for the current time Ore pe 10 H period Run O Temporary will appear on the display e M33602 The new temperature will be maintained amp Press to cancel temporary setting and only until the next programmed time period resume program schedule begins see page 9 To cancel the temporary setting at any time st O 2 6 30 10 press RUN Hold O M33603 Note Make sure the thermostat is set to the system you want to control heat or cool 13 69 2725ES 02 69 2725ES_A indd 13 d 5 4 12 11 03 u Operating Manual e Program schedule override permanent Press to permanently adjust temperature in O 6 39 10 s D M33604 Press to cancel Hold setting and resume program schedule Hold Pp 630 16 M33603 Note Make sure the thermostat is set to the system
10. as 33 See next page to adjust times and temperatures of each time period Wake 6 00 Leave 8 00 am Return 6 00 pm 0 pr 2 10 00 pm E Er 69 2725ES 02 69 2725ES A indd 10 Heat Mon Fri Cool Mon Fri Heat Sat Sun Cool Sat Sun d 5 4 12 11 03 am RTH2510 RTH2410 To adjust program schedules RTH2510 Press SET 3 times then adjust time 1 Press SET until Set Schedule is displayed Press A or W to set your Wake time for the day displayed then press SET 3 Press A or W to set the temperature for this 9 o 6 30 15 time period then press SET 1536 Set time and temperature for the next time e 3m O period Leave Repeat steps 2 and 3 for each day s time period 5 Press RUN to save amp exit m gt M33600 Press SET then set desired temperature Note Make sure the thermostat is set to the system you want to program Heat or Cool 11 69 2725ES 02 69 2725ES Aindd 11 5 4 12 11 03 u Operating Manual To adjust program schedules RTH2410 Press SET 3 times then adjust time LS GO 830910 Mo Tu We Th Fr a 18 lake Set Schedule Press SET then set desired temperature 69 2725 5 02 69 2725ES_A indd 12 M33601 1 Press SET until Set Schedule is displayed Press A or W to set your weekday Wake time Mo Fr then press SET 3 Press A or
11. sticas Pantalla con luz de fondo de lectura f cil Indica la temperatura ambiente medida en todo momento Un s lo bot n permite ver la temperatura del punto de ajuste Configuraciones del programa predeterminadas Cancelaci n temporal y permanente del horario El encendido anticipado garantiza la temperatura adecuada en el momento adecuado Protecci n del compresor incorporada 69 2725ES 02 2 69 2725ES Aindd 2 5 4 12 11 03 AM e RTH2510 RTH2410 Este termostato esta listo para funcionar Su nuevo termostato est preprogramado y listo para funcionar Todo lo que tiene que hacer es configurar el d a y la hora Luego revise las configuraciones de abajo y c mbielas si es necesario f o Configure la hora y el d a necesario para un mejor funcionamiento nennen Vea la p gina 6 Seleccione la configuraci n del sistema Predeterminada en la funci n Para cambiar vea la p gina 7 Seleccione la configuraci n del ventilador Predeterminada en la funci n Para cambiar vea la p gina 8 Cronogramas del programa Predeterminada en los niveles de ahorro de energ a para cuando est el trabajo o durmiendo Para cambiar vea las p ginas 9 a 12 CONTROL DE TEMPERATURA AL TACTO Usted podr anular la configuraci n del cronograma en cual
12. 60 1885 Douglas Dr N Golden Valley MN 55422 or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state If you have any questions concerning this warranty please write Honeywell Customer Relations 1985 Douglas Dr Golden Valley MN 55422 or call 1 800 468 1502 In
13. A PRESENTE GARANTIA ES LA UNICA GARANTIA EXPRESA QUE HONEYWELL PROPORCIONA RESPECTO DE ESTE PRODUCTO LA DURACI N DE LAS GARANT AS IMPL CITAS INCLU DAS LAS GARANT AS DE COMERCIABILIDAD Y APTITUD PARA UN OBJETIVO PARTICULAR EST LIMITADA A LA DURACI N DE UN ANO DE LA PRESENTE GARANT A Algunos estados no permiten las limitaciones sobre la duraci n del per odo de una garant a impl cita entonces la limitaci n anterior puede no resultar aplicable a su caso Esta garant a le brinda derechos legales espec ficos y usted podr tener otros derechos que var an seg n el estado Si tiene preguntas sobre la presente garant a s rvase escribir a Honeywell Customer Relations 1985 Douglas Dr Golden Valley MN 55422 o llamar al 1 800 468 1502 En Canad escriba a Retail Products ON15 02H Honeywell Limited Honeywell Limit e 35 Dynamic Drive Toronto Ontario M1V4Z9 69 2725ES 02 22 69 2725ES_A indd 22 5 4 12 11 03 an 69 2725ES_A indd 23 5 4 12 11 03 AM e Automatizaci n y control desenlace Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 http yourhome honeywell com Marca Registrada en los EE UU 2012 Honeywell International Inc 69 2725ES 02 M S 05 12 Impreso en M xico 69 2725ES_A indd 24 Honeywell 5 4 12 11 03 AM
14. Canada write Retail Products ON15 02H Honeywell Limited Honeywell Limit e 35 Dynamic Drive Toronto Ontario M1V4Z9 69 2725ES 02 22 69 2725ES_A indd 22 5 4 12 11 03 an 69 2725ES_A indd 23 5 4 12 11 03 AM e Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 http yourhome honeywell com U S Registered Trademark 2012 Honeywell International Inc 69 2725ES 02 M S 05 12 Printed in Mexico 69 2725ES_A indd 24 Honeywell 5 4 12 11 03 AM Honeywell Serie RTH2510 RTH2410 Termostato programable 69 2725ES_A indd 1 5 4 12 11 03 AM Este manual incluye los siguientes modelos RTH2510 RTH2410 PRECAUCION PELIGRO DE DANO EN EL EQUIPO Para evitar posibles da os el compresor no haga que el sistema de refrigeraci n amp funcione cuando la temperatura exterior sea inferior a 50 F 10 C Necesita asistencia Para obtener asistencia relacionada con este producto visite http yourhome honeywell com o comuniquese con el numero gratuito del servicio de atenci n al cliente de Honeywell llamando 1 800 468 1502 Lea y guarde estas instrucciones Marca registrada de los EE UU Patentes en tr mite 2012 Honeywell International Inc Todos los derechos reservados 69 2725ES Aindd 2 5 4 12 11 03 an RTH2510 RTH2410 Acerca de su nuevo termostato Arranque anticipado
15. Cool on Cooling system is on Heat on Heating system is on Aux On Auxiliary heat is activated When Heat On or Cool On is flashing compressor protection is engaged see page 15 5 69 2725 5 02 69 2725ES_A indd 5 5 4 12 11 03 u Operating Manual Set the time and day Press SET then adjust time Set Tim mG 30 O Run O SY Press SET then select current day NI 69 2725 5 02 Hold Run O 69 2725ES_A indd 6 1 Press the SET button then press A or W to set the clock time 2 Press the SET button then press A or W to select the day of the week 3 Press RUN to save amp exit M33598 amp Note If the clock flashes the thermostat will follow your settings for the Monday Wake time period until you reset the time and day M33599 5 4 12 11 03 AM RTH2510 RTH2410 Select the system setting M33612 Set SYSTEM switch to control the heating or cooling system 69 2725ES_A indd 7 The SYSTEM switch can be set to control your heating or cooling system depending on the season Cool Cooling system control Off All systems are off Heat Heating system control CAUTION EQUIPMENT DAMAGE HAZARD To prevent possible compressor damage do not operate cooling system when outdoor temperature is below 50 F 10 C 7 69 2725ES 02 5 412 11 03 am Operating Manual Select the fan setting Se
16. Honeywell RTH2510 RTH2410 Series Programmable Thermostat 69 2725ES_A indd 1 5 4 12 11 03 AM This manual covers the following models RTH2510 RTH2410 CAUTION EQUIPMENT DAMAGE HAZARD temperature is below 50 F 10 C Need Help For assistance with this product please visit http yourhome honeywell com or call Honeywell Customer Care toll free at 1 800 468 1502 Read and save these instructions U S Registered Trademark Patents pending Copyright 2012 Honeywell International Inc All rights reserved 69 2725ES Aindd 2 To prevent possible compressor damage do not operate cooling system when outdoor 5 4 12 11 03 AM RTH2510 RTH2410 Table of contents About your new thermostat Thermostat 2 Thermostat is preset ready to go 3 Quick reference to controls Quick reference to display Programming amp Operation Set time and 6 Select system setting 7 Select fan setting 8 Using program schedules 9 10 Adjust program schedule RTH2510 11 Adjust program schedule RTH2410 12 Program schedule overrides 13 14 Compressor protection 15 Early Start Change Filter 69 2725ES A indd 1
17. a set tb SQ configurar la hora y el dia Hold We mo 953 33599 69 2725 5 02 6 69 2725ES_A indd 6 5 4 12 11 03 an RTH2510 RTH2410 Seleccione la configuracion del sistema Heat Off Cool M33612 Mueva el interruptor SYSTEM para controlar los sistemas de calefacci n y refrigeraci n 69 2725ES A indd 7 El interruptor SYSTEM puede configurarse para controlar su sistema de calefacci n o refrigeraci n seg n la temporada e Cool fr o Controla el sistema de refrigeraci n e Off apagado Apaga todos los sistemas amp e Heat calor Controla el sistema de calefacci n EN EL EQUIPO Para evitar posibles dafios en el compresor no haga que el sistema de refrigeraci n funcione cuando la temperatura exterior sea inferior a 50 F 10 C A PRECAUCI N PELIGRO DE DA O 7 69 2725ES 02 5 4 12 11 03 AM Manual de funcionamiento Seleccione la configuraci n del ventilador Mueva el interruptor FAN hasta la posici n Auto u On el modo Auto la configuraci n usada comunmente el ventilador funciona sola mente cuando la calefacci n o el sistema de refrigeraci n est n encendidos Si se fija en el ventilador funciona sin interrupci n M33612 Configure el bot n FAN para seleccionar Si el ventilador funcionar sin interrupci n o solamente cuando s
18. ales a partir de la fecha de compra por parte del consumidor Si en cualquier momento durante el per odo de garant a se verifica que el producto tiene un defecto o que funciona mal Honeywell lo reparar o reemplazar a elecci n de Honeywell Si el producto tiene defectos i devu lvalo con la factura de venta u otra prueba de compra fechada al lugar donde lo compr o ii comun quese con el Centro de atenci n al cliente de Honeywell al 1 800 468 1502 Atenci n al cliente decidir si se debe devolver el producto a la siguiente direcci n Honeywell Return Goods Dock 4 MN10 3860 1885 Douglas Dr N Golden Valley MN 55422 o si se le puede enviar un producto en reemplazo Esta garant a no cubre los costos de extracci n o reinstalaci n Esta garant a no se aplicar si Honeywell demuestra que el defecto o mal funcionamiento estaba causado por dafios ocurridos mientras el producto estaba en posesi n de un consumidor La nica responsabilidad de Honeywell ser reparar o reemplazar el producto dentro de los plazos establecidos anteriormente HONEYWELL NO RESPONDERA POR LA PERDIDA O DANO DE NINGUN TIPO INCLUIDO EL DANO INCIDENTAL O INDIRECTO DERIVADO DIRECTA O INDIRECTAMENTE DEL INCUMPLIMIENTO DE LAS GARANTIAS EXPRESAS O IMPLICITAS O DE OTRAS FALLAS DE ESTE PRODUCTO Algunos estados no permiten la exclusi n o limitaci n del dario incidental o indirecto entonces esta limitaci n puede no resultar aplicable a su caso L
19. as del programa RTH2410 T Presione SET 3 veces y luego ajuste la hora GI 530 476 Ge Wake Run O Set Schedule M33601 Presione SET y luego establezca la temperatura deseada 69 2725 5 02 69 2725ES_A indd 12 e Presione SET configurar hasta que Set Schedule configurar el cronograma se muestre en la pantalla Presione o para configurar la hora en que se despierta los d as de la semana de lunes a viernes y luego presione SET Presione A o para configurar la temperatura para este per odo y luego presione SET Configure la hora y la temperatura para el pr ximo per odo Leave Repita los pasos 2 y 3 para cada per odo de d a de la semana Presione SET para configurar los per odos para el fin de semana s bado y domingo y luego presione RUN para guardar y salir Nota Aseg rese de que el termostato est configurado con el sistema que quiere programar Heat o Cool 12 e 5 412 11 03 am e RTH2510 RTH2410 Anulacion del cronograma del programa temporal Presione para ajustar temporalmente la temperatura 980 5 30 10 Hold Run O Sa 33602 Presione para anular la configuraci n temporal y volver al cronograma del programa set O e Hold 530 9 107 Cri 33603 Nota Asegurese de que el termostato est configurado con el sistema que usted quiere controlar calor o frio 13 69 2725ES_A indd 13 e
20. ched at the time you set For example Set the Wake time to 6 am and the temperature to 70 The heat will come on before 6 am so the temperature is 70 by the time you wake at 6 The next time e period is displayed when the system is acti vated before a scheduled time period 5 412 11 03 am RTH2510 RTH2410 Change Filter Change Filler Press amp Hold Run to Reset If the filter reminder is turned on during O 2 49 NIE installation the words Change Filter will flash Hold O 15 on the screen when the filter needs to be Run O replaced m33632 After you replace the air filter press and hold amp the RUN button for 3 seconds to reset the alert amp 17 69 2725 5 02 69 2725ES_A indd 17 5 4 12 11 03 u Operating Manual Battery replacement Pull at bottom to remove thermostat from wallplate Install two fresh AAA batteries when Lo Batt flashes on the screen Lo Batt appears for 60 days before the batter ies are depleted Turn thermostat over insert fresh AAA alkaline batteries then reinstall thermostat Replace batteries once a year or when you will be away for more than a month Most settings are stored in non volatile permanent memory Only the clock and the day must be set after you replace the batteries 2 Set the System switch to Off before removing the B nmg A batteries Otherwise the heating cooling system could q
21. ea necesario 69 2725ES 02 8 69 2725ES_A indd 8 5 4 12 11 03 an RTH2510 RTH2410 Ahorre dinero configurando los cronogramas del programa Es facil programar su sistema que permite un ahorro maximo de energia Usted puede pro gramar cuatro periodos por dia con diferentes configuraciones para los dias de semana y los fines de semana WAKE 6 00 70 F D 77 LEAVE 8 00 a m Bes 52 F p RETURN 6 00 p m JF SLEEP 10 00 p m 50 69 2725ES_A indd 9 Programe la hora en que se despierta y la temperatura que quiere durante la hasta que usted se va de su casa Programe la hora en que usted se va de su casa y la temperatura amp que quiere mientras no est en su casa por lo general un nivel de ahorro de energ a Programe la hora en que regresa a su casa y la temperatura que quiere durante la tarde hasta que se va a dormir Programe la hora en que usted se va a dormir y la temperatura que quiere durante toda la noche por lo general un nivel de ahorro de energ a 9 69 2725ES 02 5 4 12 11 03 AM 69 2725ES_A indd 10 d Manual de funcionamiento Configuraciones de ahorro de energia para ahorro de costos Este termostato viene predeterminado con configuraciones para un programa de ahorro de energia Recomendamos estas configuraciones debido a que reducen los ga
22. o programado 16 d 5 4 12 11 03 am RTH2510 RTH2410 Cambio del filtro Change Filler Press amp Hold Run to Reset Si el recordatorio de cambio del filtro se activa se O O 5 30 17 durante la instalaci n las palabras Change Hold O 15 Filter cambie el filtro destellar n en la Run eq O pantalla cuando deba cambiar el filtro 33632 Despu s de que reemplace el filtro de aire e presione y sostenga presionado el bot n RUN e ejecutar durante 3 segundos para reiniciar la alerta 17 69 2725ES 02 69 2725ES Aindd 17 5 4 12 11 03 u e Manual de funcionamiento Reemplazo de la bateria Instale dos pilas AAA nuevas cuando Lo Batt parpadee en la pantalla El icono aparecera 60 dias antes de que las pilas est n completamente descargadas Hale de la parte inferior para quitar el termostato de la placa para pared Reemplace las pilas una vez por Gire el termostato e luego de una ausencia de mas de un mes inserte baterias AAA alcalinas nuevas luego vuelva a instalar el termostato La mayor parte de los datos de la configuraci n est n almacenados en la memoria no vol til permanente S lo el reloj y la fecha deben ajustarse max despu s del reemplazo de las pilas Ponga el conmutador del sistema en OFF antes de retirar las pilas De lo contrario el sistema de calefacci n enfriamiento puede permanecer activado aun cuando se hayan sacado las
23. otecci n del compresor incorporada eam pa O 6 30 TE We al Wake E M32711 El mensaje titila hasta que haya transcurrido el tiempo de reinicio de seguridad 69 2725ES_A indd 15 Esta funci n ayuda a prevenir el dafio del compresor en su acondicionador de aire en su sistema de bomba de calor El compresor puede dafiarse si se vuelve a iniciar inmediatamente despu s de ser apaga do Esta caracteristica hace que el compresor demore 5 minutos antes de volver a iniciarse Durante el tiempo de espera la pantalla mostrara el mensaje Cool Heat si tiene una bomba de calor Cuando haya transcurrido el tiempo de espera de seguri dad el mensaje dejara de titilar y se encend era el compresor 15 69 2725 5 02 d 5 4 12 11 03 am Manual de funcionamiento e Arranque anticipado LI IL We am Cool Wake On M32712 69 2725 5 02 69 2725ES_A indd 16 Arranque anticipado esta caracteristica permite que se active la calefacci n o refrigeraci n antes de la hora de inicio del programa para que alcance la temperatura a la hora que usted configur Por ejemplo configure la hora para despertarse a las 6 a m y la temperatura a 70 F 21 1 C La calefacci n se activar antes de las 6 a m para que la temperatura est a 70 F 21 1 C para cuando se levante a las 6 El siguiente per odo se muestra cuando el sistema se activa antes de un per od
24. quier momento y ajustar manualmente la temperatura vea las p ginas 13 y 14 3 69 2725ES 02 69 2725ES_A indd 3 5 4 12 11 03 u e Manual de funcionamiento R pida referencia de los controles Set configuraci n Presione este bot n para configurar la hora el d a o el cronograma Pantalla Se ilumina durante 12 segundos cuando se presiona cualquier bot n Ajuste de la temperatura L vea las p ginas 13 a 14 Hold suspender Presi nelo para anular el control de temperatura programada Interruptor Fan ventilador vea la p gina 8 On encendido El ventilador funciona sin interrupci n Auto autom tico El ventilador funciona solamente 2 cuando la calefacci n o el Interruptor System del sistema vea la p gina 7 sistema de refrigeraci n est n Heat calor Controla el sistema de calefacci n encendidos e Off apagado Apaga todos los sistemas Cool fr o Controla el sistema de refrigeraci n 69 2725ES 02 4 Run restablecer Presione para volver al cronograma del programa Fan Heat Off Cool Auto On M33612 69 2725ES_A indd 4 5 4 12 11 03 an e RTH2510 RTH2410 Rapida referencia de la pantalla Indicador de punto de ajuste Aviso de bateria baja Aparece cuando se visualiza FU la p gina 18 el punto de ajuste de 0 la temperatura epee Temperatura
25. stos de calefacci n y refrigeraci n hasta en un 33 Vea la siguiente p gina para ajustar las horas y las temperaturas de cada per odo de lunes a viernes de lunes a viernes s bado y domingo s bado y domingo Wake 6 00 a Leave 8 00 Return 6 00 p m ul Sleep 2 10 00 p 69 2725ES 02 5 412 11 03 aM e RTH2510 RTH2410 Para ajustar los cronogramas del programa RTH2510 Presione SET 3 veces y luego ajuste la hora 1 2 et 27 jm Lf ORO 530105 Hold Mo l ki Ga Schedule 4 M33600 Presione SET y luego establezca la 5 temperatura deseada 69 2725ES_A indd 11 Presione SET configurar hasta que Set Schedule configurar el cronograma se muestre en la pantalla Presione A o para configurar la hora para despertarse para el dia que se muestra y luego presione SET Presione para configurar la temperatura para este periodo y luego presione SET Configure la hora y la temperatura para el pr ximo per odo Leave Repita los pasos 2 y 3 para el per odo de tiempo de cada d a Presione RUN para guardar y salir Nota Aseg rese de que el termostato est configurado con el sistema que quiere programar Heat o Cool 11 69 2725ES 02 5 412 11 03 am Manual de funcionamiento e Para ajustar los cronogram
26. t the FAN switch to Auto or On In Auto mode the most commonly used setting the fan runs only when the heating or cooling system is on If set to On the fan runs continuously e M33612 Set FAN switch to choose whether the fan runs continuously or only as needed 69 2725 5 02 8 69 2725ES_A indd 8 5 4 12 11 03 an RTH2510 RTH2410 Save money by setting program schedules It s easy to program your system for maximum energy savings You can program four time periods each day with different settings for weekdays and weekends p WAKE 6 00 am mre 70 og LI LEAVE 8 00 am EJ LL RETURN 6 00 pm 10 SLEEP 10 00 pm m oc 69 2725ES_A indd 9 Set to the time you awaken and the temperature you want during the morning until you leave for the day Set to the time you leave home and the temperature you want while you are away usually an energy saving level Set to the time you return home and the temperature you want during the evening until bedtime Set to the time you go to bed and the temperature you want overnight usually an energy saving level 9 69 2725 5 02 5 4 12 11 03 AM Operating Manual Energy saving settings for maximum cost savings This thermostat is pre set to use energy saving program settings We recommend these settings since they can reduce your heating cooling expenses by as much
27. terna Mueva el interruptor System hasta la posici n Cool vea la p gina 7 Asegurese de que la temperatura sea m s baja que la temperatura interna Espere 5 minutos para que responda el sistema 20 5 4 12 11 03 AM RTH2510 RTH2410 En caso de inconvenientes Las con Asegurese de que las temperaturas de calor y frio est n configuradas en rangos figuraciones de aceptables la temperatura noe Heat De 40 F a 90 F de 4 5 C a 32 C cambian Cool De 50 F a 99 F de 10 C a 37 C El mensaje e La funci n de la protecci n del compresor est funcionando Espere 5 Cool On o Heat minutos para que el sistema se vuelva a iniciar de forma segura sin da ar el On titila compresor vea la p gina 15 e Heat On no e Mueva el interruptor System hasta la posici n Heat y configure el nivel de e aparece en la temperatura por encima de la temperatura ambiente actual vea la p gina 7 pantalla Cool On no e Mueva el interruptor System hasta la posici n Cool y configure el nivel de aparece en la temperatura por debajo de la temperatura ambiente actual vea la pagina 7 pantalla 21 69 2725 5 02 69 2725ES_A indd 21 d 5 4 12 11 03 u e Manual de funcionamiento Garantia limitada de 1 ano Honeywell garantiza este producto a excepci n de la bater a por el t rmino de un 1 afio contra cualquier defecto de fabricaci n de los materi
28. ud remain activated even when batteries are removed 69 2725ES 02 18 69 2725ES Aindd 18 d 5 4 12 11 03 am e RTH2510 RTH2410 Customer assistance Pull at bottom to remove thermostat from wallplate For assistance with this product please visit http yourhome honeywell com Or call Honeywell Customer Care toll free at 1 800 468 1502 To save time please note your model num ber and date code before calling Turn thermostat over toy find model number and N Accessories date code RTO BS nE M32707 19 69 2725 5 02 69 2725ES_A indd 19 5 4 12 11 03 u Operating Manual In case of difficulty If you have difficulty with your thermostat please try the following suggestions Most problems can be corrected quickly and easily Display is blank Heating or cooling system does respond 69 2725ES 02 69 2725ES A indd 20 Make sure furnace door is closed securely Make sure fresh AAA alkaline batteries are correctly installed see page 18 Set system switch to Heat see page 7 Make sure the temperature is set higher than the Inside temperature Set system switch to Cool see page 7 Make sure the temperature is set lower than the Inside temperature Wait 5 minutes for the system to respond 20 5 4 12 11 03 AM RTH2510 RTH2410 In case of difficulty Temperature settings do not change