Home
LG Electronics LT1235HNR Use and Care Manual
Contents
1. Figure 1 15 17 32 394 mm Expanded aluminum metal grille LGE Wall Sleeve Figure 2 ELECTRICAL SERVICE Check your available electrical service The power supply available must be the same as that shown on the unit nameplate found on left side of cabinet All models are equipped with a 3 prong service plug to provide proper service and safe positive grounding Do not change plug in any way Do not use an adapter plug If your present wall outlet does not match your plug call a qualified electrician to make the necessary corrections SAVE CARTON for storage and this OWNER S MANUAL for future reference The carton is the best way to store unit during winter or when not in use A CAUTION To avoid risk of personal injury property damage or product damage due to the weight of this device and sharp edges that may be exposed Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit e Carefully inspect location where air conditioner will be installed Be sure it will support the weight of the unit over an extended period of time e Handle air conditioner with care Wear protective gloves whenever lifting or carrying the unit AVOID the sharp metal fins of front and rear coils Make sure air conditioner does not fall during installation REQUIRE
2. E Cuando la profundidad del alojamiento existente es igual o menor a 45 72 cm 18 pulgadas pase directamente al paso 7 Corte los deflectores y los bloques de soporte seg n la longitud A de la tabla que se muestra abajo 16 Extraiga la parte posterior de los bloques de soporte y fijelos al interior del alojamiento de la pared seg n se muestra en la FIG 20 Deslice el deflector en las ranuras de los bloques de soporte Apriete los tornillos Figure 17 Alojamiento Pared de la pared Bloque de soporte Figure 20 16 Aire Acondicionado Instalaci n PROCEDIMIENTO C Extraiga el refuerzo de las tiras de reborde 33 02 13 y fijelas seg n se muestra abajo en la FIG 22 La parte superior del reborde debe colocarse enfrente del reborde en la base del alojamiento de la pared 1 High se High Figure 21 Figure 22 8 Instale la nueva unidad en el alojamiento de la pared Para montar el reborde inserte el saliente de cada pieza en la ranura de la otra pieza seg n se muestra abajo Deslice el reborde sobre la parte frontal del aparato de aire acondicionado hasta que el reborde est unido a pa o con el alojamiento seg n se muestra a continuaci n Adorno 2ea Figure 23 A PRECAUCION e Los aparatos de aire acondicionado de los que trata este manual constituyen un pe
3. LG Life s Good HSITIN TONWdS4 OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your air conditioner and retain it for future reference TYPE WINDOW MODELS LT1035HNR LT1235HNR MIMI P NO MFL68744001 www lgappliances com Window Type Air Conditioner Owner s Manual TABLE OF CONTENTS Y FOR YOUR RECORDS Safety Precautions 3 Write the model and serial numbers here Model Before to Operation 7 Serial You can find them on a label on the side of each unit rocio 8 Dealer s Name Date Purchased E Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues Electrical Safety 9 Installation 11 yo READ THIS MANUAL Operating Instructions 18 Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and Maintenance and Service 21 money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all A PRECAUTION e Contact the authorized service technician for repair or maintenance of this unit e Contact the installer for installation of this
4. Manual del usuario 9 Seguraida Electrica IMPORTANTE FAVORLEA CON ATENCI N POR LA SEGURIDAD PERSONAL DEL USUARIO ESTE APARATO DEBE SER DEB DAMENTE NEUTRALIZADO El cord n de energ a de ste aparato esta equipado con tres patas cable a tierra Utilice ste con un enchufe de pared de tres salidas a tierra para minimizar el peligro de choque el ctrico El cliente debe revisar el receptor de pared y el circuito por un electricista calificado para asegurarse que la recepci n esta debidamente neutralizada 10 Aire Acondicionado NO CORTE O REMUEVA LA TERCERA PATA GROUND DEL ENCHUFE A SITUACIONES EN LAS CUALES EL APARATO ES DESCONECTADO OCASIONALMENTE Debido al peligro potencial nosotros no recomendamos el uso de adaptadores Sin embargo si usted desea utilizar un adaptador una CONEXI N TEMPORAL puede ser efectuada Utilice adaptadores UL disponibles en la mayor a de los estable cimientos de herramientas La pata mas grande del adaptador debe ser alineada con la pata mas grande del interruptor para asegurarse una polarizaci n adecuada A PRECAUCION Adaptar la terminal del ground del adaptador a la cubierta de la pared con un tornillo no neutraliza el aparato a menos que la cubierta del tornillo sea de metal u no sea insolada y el receptor de pared este neutralizado a trav s del alambrado del la casa El cliente debe hacer verificar el circuito por un electricista calificado para asegurarse q
5. A Rejilla posterior 19 84 cm 7 1346 tu A Vista superior Figure 15 4 Extraiga la parte posterior de la tira de Aislamiento horizontal de 3 5 x 3 5 x 69 06 cm 13 8 x 13 8 x 273 16 y fijela a la parte inferior interna del alojamiento seg n se muestra abajo Extraiga la parte posterior de la tira de Aislamiento lateral de 3 5 x 3 5 x 156 21 cm 13 8 x 13 8 x 611 2 y f jela al interior frontal del alojamiento seg n se muestra abajo a Si el alojamiento de la pared no tiene una rejilla posterior o un panel con lamas instale la rejilla de pl stico del equipo de instalaci n Corte la rejilla de pl stico a unas medidas de 67 31 cm 26 1 2 de ancho y 39 37 cm 15 1 2 de alto SS ee We ee EI F 5 Sos ss s cece 5 3 E SS SS ES 2 2 SS Figure 18 Coloque la rejilla de pl stico Figure 16 8 Cuando la profundidad del alojamiento existente es igual o menor a 45 72 cm 18 pulgadas pase directamente al paso 7 De otra manera corte los desviadores y los bloques del soporte de acuerdo a la longitud A en el cuadro siguiente Profundidad D del alojamiento Longitud A 2 de pared ya existente pulgadas pulgadas D Bloque 18 lt D lt 18 3 4 de soporte 18 5 a lt D lt 19 1 9 4 Deflector 19 5 lt D lt 22 4 A Figure 19
6. When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload The current interrupter Press the RESET button located on the power device is tripped cord plug If the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Air conditioner Airflow is restricted Make sure there are no curtains blinds or does not cool furniture blocking the front of the air conditioner as it should Emone Aar nn pei eey LL TT The air filter is dirty Clean the filter at least every 2 weeks See the care and Maintenance section The room may have been When the air conditioner is first turned on you hot need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and cold air returns Cooling coil have iced up See Air Conditioner Freezing Up below Air conditioner The cooling coils are iced Ice may block the air flow and obstruct the air freezing up over conditioner from properly cooling the room Set the mode control at High Fan or High Cool Water drips Hot humid weather This is normal outside Water drips The air conditioner is not For proper water disposal make sure the air indoors tilted to the outside ee slants slightly from the case front to the rear Water collects Moisture removed from air This is normal for a short period in areas with in base pan
7. 4 15 Carrier 51S Series 25 3 4 16 7 8 18 5 8 Friedrich 27 16 3 4 16 3 4 12 Room Air Conditioner 6 Install new unit into wall sleeve 44 CAUTION When installation is completed the replacement unit MUST have a rearward slope as shown To achieve 1 4 slope remove the backing from the 11 13 16 shim strips and attach them as shown below in Fig 3 Place the higher portion of the shim to the front of the rib on the base of the wall sleeve y hight o High UNIT Wall Sleeve Le SHIM PLACEMENT UNIT INSTALLATION Figure 3 Installation PROCEDURE A 14 If you are using the new sleeve optionally supplied with your unit skip to step 3 Otherwise install the plastic grille from the kit Cut the plastic grille to 25 1 2 wide and 15 1 4 high Place the plastic grille to the inside of the wall sleeve at the rear flange 14 Install the new unit into the wall sleeve B To assemble trim snap the tab of each piece SS ee eS eS 5 ds es sen Figure 4 into the slot of the other piece as shown below Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below Fasten the 4 washer screws to secure the grille to the wall sleeve If you need plastic nuts to mount plastic grille to the inside of the wall sleeve there are plastic nuts in the installation kit The nuts are in
8. Le E gt Pa gt vI 6 Aire Acondicionado No bloquee la entrada ni la salida del flujo de aire e Puede causar una aver a en Inserte siempre el filtro correctamente L mpielo cada dos semanas acondicionado e El funcionamiento sin filtros puede provocar fallos Evite un enfriamiento excesivo y ventile en e De lo contrario podr a da ar Utilice un pa o suave para limpiar No utilice cera disolventes o detergentes fuertes e La apariencia del aparato de aire acondicionado puede deteriorar cambiar el color o desarrollar flujos en las superficies No beba el agua que drena el aparato de aire e Contiene elementos de contenci n y hacer que se enferme No introduzca la mano ni barras en la entrada o salida del aire durante el funcionamiento del aparato e De lo contrario podr an ocurrir lesiones personales Si el l quido de las pilas alcanzara su boca cepille sus dientes Y consulte a un m dico No utilice el mando a distancia si las pilas han experimentado ugas Los productos qu micos de las pilas podr an causar quemaduras u otros perjuicios a la salud Antes de la Operaci n Preparar para el funcionamiento 1 Contactar un especialista para la instalaci n 2 Coloque el enchufe correctamente 3 No comparta la salida con otros artefactos 4 No use un cable de extensi n 5 No arranque detenga el funcionamiento enchufando desenchufando el cable de corri
9. O DE CUALQUIER OTRA MANERA ALGUNOS ESTADOS NO PERMITEN LA EXCLUSI N O LIMITACI N DE DA OS IMPREVISTOS O RESULTANTES O LIMITACIONES A LA DURACI N DE LAS GARANT AS IMPL CITAS POR LO QUE LA EXCLUSI N O LIMITACI N MENCIONADA ANTERIORMENTE NO SER APLICABLE AL USUARIO ESTA GARANT A LE OTORGA DERECHOS LEGALES ESPEC FICOS Y TAMBI N PUEDE TENER OTROS QUE VARIAR N DE UN ESTADO A OTRO COMO OBTENER EL SERVICIO DE ESTA GARANT A E INFORMACI N ADICIONAL Llame al 1 800 243 0000 o visite nuestra p gina web www lg com Direcci n de correo ordinario LG Customer Information Center ATTN CIC 201 James Record Road Huntsville AL 35824 LG Life s Good LG Customer Information Center 1 800 243 0000 Register your product Online LG ELECTRONICS INC 1000 Sylvan Ave Englewood Cliffs NJ 07632 www Igappliances com
10. Sleeve Support Block Figure 20 PROCEDURE C Remove the backing from the 13 shim strips and attach them as shown below in Figure 22 The higher portion of shim is to be placed in front of the rib on the base of wall sleeve se High Figure 21 1 high soe ee ee ten es Figure 22 a Install the new unit into the wall sleeve E To assemble trim snap the tab of each piece into the slot of the other piece as shown below Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below Aa Trim 2 ea Figure 23 Installation A CAUTION e Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit e When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils e Make sure air conditioner does not fall during removal Owner s Manual 17 HSITDNA Operating Instructions E Operating Instructions Remote Control Operations __ 7 D E cl O 6 Saver Filter 9 y HDL Filter Reset Fan Fan lt 2 TEMP Heat Timer ox 2 pua a p 3 i 8 FAN MODE TIMER SPEED POWER p e i LL D 3 2 Lj 1 POWER Operation starts when this button is pressed
11. Wall sleeve must be securely fastened in wall before installing the air conditioner Use the nails or screws through sleeve into wall if needed Repaint sleeve if needed 8 Prepare the wall sleeve for installation of the unit If you plan to use your existing wall sleeve and it is not LGE use procedure B or Washer Screw C below Procedure Brand Depth inches A LGE 16 23 32 White Westinghouse Frigidaire Carrier 16 We 52F series Of B General Electric f Hotpoint heil Whirlpool 17 1 8 or 23 Carrier 51S series 18 5 8 16 3 4 z Fedders Emerson or 19 3 4 Emerson Fedders 15 Friedrich 16 3 4 Nuts Plastic Plastic grille 263 4 x 161 2 1 Horizontal Insulation Strips 1 x 5g x 278 16 1 13 8 X 198 X 27346 1 Around Insulation Strips ex Su x 61 1 198 X 198 x 611 2 1 Support Block 13 4 X 198 X 45 16 2 Baffle 14 x 42 X 1 8 1 Shim 13 x 1x 34 2 Trim Frame 2 4 4 1 Grille Rear HOW TO INSTALL 1 Identify the existing wall sleeve before installing the unit from the listed below Brand Wall Sleeve Dimensions inches fer Width Height Depth White Westinghouse Frigidaire as 112 15 1 4 16 1 2 Carrier 52F series General Electric Hotpoint 26 15 5 8 16 7 8 17 1 8 Whirlpool 25 7 8 16 1 2 or 23 Fedders Emerson 27 16 34 16 34 or 19 3 4 LGE 25 7 8 15 17 32 16 23 32 Emerson Fedders 26 3 4 15 3
12. alimentaci n afiladas de metal de las bobinas frontal y posterior disponible debe coincidir con la que se muestra en la etiqueta Aseg rese de que el aparato de aire acondicionado no cae al suelo identificativa de la unidad que se encuentra en el lado izquierdo durante la instalaci n del alojamiento a sa HERRAMIENTAS NECESARIAS Todos los modelos est n equipados con un enchufe de servicio de 3 clavijas con una toma de tierra positiva segura No i Guantes ajustados rc Ayto de bl modifique el enchufe de ninguna manera No utilice un enchufe Destornillador est ndar 2 le REDE adaptador Si su toma de corriente en la pared no coincide con Destornillador Philips f T gaca lad el enchufe llame a un electricista cualificado para realizar los Cuchillo afilado Lava artcuiada cambios necesarios GUARDE LA CAJA para el Cinta para medir i ie an io de almacenamiento y esta GU A DEL PROPIETARIO para futura trinquete puigaca y referencia La caja es la mejor manera de almacenar la unidad Taladro el ctrico durante el invierno o cuando no se utilice Broca de taladro de 0 64 cm 1 4 de pulgada Manual del usuario 11 Instalaci n INSTALACI N A PRECAUCION Se recomienda encarecidamente la extracci n del antiguo alojamiento en la pared y la instalaci n de un nuevo alojamiento de pared Comfort Aire Si decide mantener el alojamiento de pared existente tendr que ajustar la direcci n de la rejilla e
13. cool heat or recirculate room air only Pull the lever to the OPEN position to exhaust smoke or stale air from the room This feature is best used in conjunction with the FAN ONLY position Air Direction The direction of air can be controlled by adjusting the horizontal and vertical louvers e HORIZONTAL AIR DIRECTION e VERTICAL AIR DIRECTION CONTROL CONTROL The horizontal air direction is adjusted by The vertical air direction is adjusted by moving moving the vertical louver the horizontal louver The lever for the vertical louver is located in the right and left side of the air discharge 20 Room Air Conditioner Maintenance and Service TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET Air Filter Cleaning i The air filter should be checked at least twice a month to see if cleaning is necessary Trapped particles in the filter will build up and block the airflow This reduces the cooling capacity and also causes an accumulation of frost on the cooling coils HSITDNA If the filter becomes worn or damaged you should replace immediately Replacement filters are available from your salesperson dealer and the authorized customer service centers 1 Open the inlet grille downward by pulling out the top of the inlet grille 2 Remove the air filter from the front grille assembly by pulling the air filter up slightly 3 Wash the filter using lukewarm water below 40 C 104 F 4 Gentl
14. en el interior del alojamiento de la pared seg n se muestra en la FIG 13 Deslice el deflector en las ranuras de los bloques de soporte ee o 7 516 Pared Alojamiento de pared Bloque de soporte Figure 13 Instale la nueva unidad en el alojamiento de la pared Para montar el reborde inserte el saliente de cada pieza en la ranura de la otra pieza seg n se muestra abajo Deslice el reborde sobre la parte frontal del aparato de aire acondicionado hasta que el reborde est unido a pa o con el alojamiento seg n se muestra a continuaci n Aa Adorno 2ea Figure 14 Instalaci n A PRECAUCION e Los aparatos de aire acondicionado de los que trata este manual constituyen un peligro de peso excesivo Se necesitan dos o m s personas para mover e instalar la unidad Para evitar heridas o problemas musculares utilice t cnicas adecuadas para elevar y desplazar la unidad Al manejar el aparato de aire acondicionado tenga cuidado de evitar cortes de las aletas afiladas de metal en las bobinas frontal y trasera e Aseg rese de que el aparato de aire acondicionado no cae al suelo durante la instalaci n m u az gt Z O e Manual del usuario 15 Instalaci n PROCEDIMIENTO C 1 Coloque la direcci n de la rejilla en la parte posterior del alojamiento de la pared en un ngulo de 60 seg n se muestra en la FIG 15 Se recomienda el uso de tenazas 60
15. en el plazo de siete d as naturales 7 a partir de la fecha de entrega 9 Los da os o la p rdida de componentes de cualquier producto cuya caja haya sido abierta haya sido objeto de un descuento o se haya restaurado 10 Los productos cuyos n meros de serie de f brica originales hayan sido quitados borrados o cambiados de ninguna manera 11 Las reparaciones cuando el producto se utiliza para cualquier cosa fuera de lo normal y del uso dom stico habitual por ejemplo su alquiler uso comercial en oficinas o en instalaciones de ocio o en contra de la instrucciones que se indican en el manual del propietario 12 La extracci n y reinstalaci n del producto si est instalado en un lugar inaccesible ESTA GARANT A SE OTORGA EN SUSTITUCI N O EXCLUSI N DE TODA OTRA GARANT A EXPRESA O IMPL CITA INCLUYENDO SIN LIMITAR CUALQUIER GARANT A DE CALIDAD O IDONEIDAD CON UN PROP SITO CONCRETO EN LA MEDIDA EN QUE CUALQUIER GARANT A IMPL CITA ES OBLIGADA POR LA LEY EST LIMITADA EN DURACI N AL PERIODO DE GARANT A YA MENCIONADO LA REPARACI N O REEMPLAZO DE PIEZAS SEG N LO ESTABLECIDO EN ESTA GARANT A ES EL NICO QUE PUEDE RECLAMAR EL CLIENTE NI EL FABRICANTE NI SU DISTRIBUIDOR EN LOS EE UU SE HACE RESPONSABLE DE CUALQUIER DA O DERIVADO INDIRECTO ESPECIAL O PENAL DE CUALQUIER NATURALEZA INCLUYENDO SIN LIMITACION LA P RDIDA DE INGRESOS O BENEFICIOS O CUALQUIER OTRO TIPO DE DA O A N BASADO EN UN CONTRATO SEA UN AGRAVIO
16. en un numero mas alto El filtro de aire est sucio Limipe el filtro pro lo menos cada dos semanas Vea la secci n de instrucciones de operaci n El cuarto a n est caliente Cuando usted enciende el aire acondicionado debe esperar un momento para que la habitaci n se enftre El aire frio se est escapando Aseg rese que todas las salidas de aire est n cerradas para que el aire regrese El serpentin de refrigeraci n se ha Establezca una temperatura m s alta congelado El aire El hielo bloquea el flujo de aire y Elija el modo alto del ventilador High Fan o enfriado alto acondiciona do detiene el enfriamiento del cuarto High Cool enfria dernasiado Hay goteo de agua Clima caliente y himedo Esto es normal en la parte externa Hay goteo de El acondicionador de aire no esta Para una salida correcta del agua asegurese de que el aguaen la parte inclinado hacia el exterior acondicionador de aire se incline levemente desde la interna parte frontal hasta la parte trasera de la caja Se acumula agua Se elimino la humedad del aire y se Esto es normal durante un peri do corto en afeas con en la bandeja drena en la bandeja poca humedad es normal durante un per odo m s largo en areas muy humedas El aparato de aire Filtro de aire sucio flujo de aire Limpie el filtro acondicionado se _ restringido eee enciende y apaga La temperatura exterior es Establezca el ventilador en una velocidad m s alta para r pidamente extrema
17. la grapadora para el momento que lo necesite para probar la fecha de su adquisici n Instalaci n eee 11 o para la validaci n de la garant a yo LEA ESTE MANUAL En su interior encontrar muchos consejos tiles sobre la utilizaci n y Mantenimiento de su acondicionador de aire Unos pocos Cuidado y Mantenimiento 21 cuidados por su parte le pueden ahorrar mucho tiempo y dinero durante la vida de su acondicionador de aire En la tabla de consejos para la soluci n r pida de problemas encontrar muchas respuestas a los problemas m s habituales Si revisa primero nuestra Tabla de Consejos para la soluci n r pida de problemas tal vez no necesite llamar nunca al servicio t cnico A PRECAUCI N P ngase en contacto con un t cnico del servicio autorizado para realizar la reparaci n y mantenimiento de esta unidad e P ngase en contacto con un instalador para realizar la instalaci n de esta unidad e Cuando se va a cambiar el cable el ctrico el trabajo de reemplazamiento debe ser realizado nicamente por personal autorizado utilizando las piezas de cambio genuinas nicamente e El trabajo de reemplazamiento debe ser realizado de acuerdo con el C digo El ctrico Nacional nicamente por personal autorizado Instrucciones operativas 18 2 Aire Acondicionado Precauciones de seguridad E Precauciones de seguridad Para evitar lesiones al usuario o a otras personas y da os a la propiedad es
18. over 20 between the back of the air conditioner and the wall or fence behind it 4 Close all doors and windows and check for any source of heat in the room Water drip from the rear of the unit You see water dripping from the rear of the unit Water may be collected in the base pan in highly humid conditions or on rainy days This water overflows and drips from the rear of the unit Normal S Pinging or Swishing High pitched Chatter Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Vibration Gurgling or hissing noise may be a heard due to refrigerant passing aie gy Vibrate and of poor through evaporator during normal wall or window construction operation or incorrect installation 22 Room Air Conditioner Maintenance and Service The air conditioner may be operating abnormally when Air The air conditioner is Make sure the air conditioner plug is pushed conditioner unplugged completely into the outlet coes not The fuse is blown circuit Check the house fuse circuit breaker box and Sia breaker is tripped replace the fuse or reset the breaker Power failure If power failure occurs turn the mode control to Off
19. pase directamente al paso 4 Si el alojamiento de la pared no tiene una rejilla posterior ni un panel con lamas instale la rejilla de pl stico del equipo de instalaci n Corte la rejilla de pl stico a unas medidas de 64 77 cm 25 1 2 de ancho y 38 74 cm 15 1 4 de alto Coloque la rejilla de pl stico en el interior del alojamiento de pared en el flanco posterior cae SS Soo oe oes es te SS ese SS sce SS eeens y Figure 11 B Cuando la profundidad del alojamiento existente es igual o menor a 45 72 cm 18 pulgadas pase directamente al paso 6 En caso contrario corte los deflectores y los bloques de soporte seg n la longitud A de la tabla que se muestra abajo Profundidad D del alojamiento Longitud A de pared ya existente pulgadas pulgadas Coloque la rejilla de pl stico Figure 9 A S Bloque 18 lt D lt 18 s 3la de soporte 18 s lt D lt 19 3 4 1 3 4 Deflector 19 5 lt D lt 22 4 Al Figure 12 E Cuando el alojamiento de la pared tiene una rejilla posterior de panel con lamas salte al paso 3 y omita el paso 4 Coloque la rejilla de pl stico en el interior del alojamiento de pared en el flanco posterior Apriete los tornillos Figure 10 14 Aire Acondicionado PROCEDIMIENTO B 16 Extraiga la parte posterior de los bloques de soporte y f jelos
20. utilizar el transporte de nuestra elecci n para desplazar la unidad al y del centro de servicio autorizado de LG ESTA GARANT A LIMITADA NO SE APLICA A 1 Las visitas de Asistencia a domicilio para entregar recoger y o instalar el producto instruir o sustituir fusibles 2 Sustituci n de fusibles de la casa o reajuste de interruptores de circuito la correcci n del cableado de la casa o de la tuber a o la correcci n de la instalaci n del producto 3 Los da os o aver as causados por fugas roturas congelaci n de tuber as de agua l neas de drenaje restringido suministro insuficiente de agua o interrumpido o suministro insuficiente de aire 4 Los da os o aver as causados por accidentes plagas e insectos rayos viento fuego inundaciones o actos de Dios 5 Los da os o fallos ocasionados por el mal uso abuso instalaci n inadecuada reparaci n o mantenimiento Se considera reparaci n inadecuada aquella en que se hayan utilizado piezas no aprobadas o especificadas por LG 6 Los da os 0 aver as causados por modificaciones no autorizadas o alteraciones del producto 7 Los da os o aver as causados por la utilizaci n de una corriente el ctrica tensi n o c digo de plomer a incorrectos 8 Da os est ticos incluyendo ara azos abolladuras desportilladuras u otros da os en el acabado del producto a menos que dichos da os sean el resultado de defectos en los materiales o mano de obra y se informe a LG
21. D TOOLS e 3 8 inch open end wrench or adjustable wrench e 1 4 inch hex socket and ratchet e Tape measure e Electric drill e 1 4 inch drill bit e Tight Fitting gloves e Standard screwdriver e Phillips screwdriver e Pliers e Sharp knife Owner s Manual 11 HSITDNA Installation INSTALLATION A CAUTION We strongly recommend the removal of the old wall sleeve and the installation of a new LGE Wall Sleeve If you decide to keep the existing wall sleeve you have to redirect the louvers at the back of the wall sleeve illustration The use of pliers is recommended If you DO NOT redirect you run the risk of poor performance or product failure This is not covered under the terms of the LGE warranty e Pick a location which will allow the conditioned air to blow into the area you want Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed ITEMS IN INSTALLATION HARDWARE You may not need all parts in the kit Discard unused parts ITEM inches Qty NOTICE All wall sleeves used to mount the new air conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve or rear flange that serves as a stop for the air conditioner A Remove the old air conditioner from existing wall sleeve B Clean the interior of the existing sleeve Do not disturb seals a
22. Do not open the suction inlet grill of the product during operation If water enters the product turn off the the power switch of the main body of appliance Contact service center after taking the power plug out from the socket e Otherwise it may electrical shock and failure Turn off the power and _ Unplug the unit when not preakar first when cleansing using it for a long time e unit e Since the fan rotates at high e Prevent accidental startup and speed during operation it may the possibility of injury Do not operate or stop the unit by inserting or pulling out the power plug e It will cause electric shock or fire due to heat generation Hold the plug by the head when taking it out e It may cause electric shock and damage Do not damage or use an unspecified power cord e lt will cause electric shock or fire X af LB Dr gt a PI OT WC When gas leaks open the window for ventilation before operating the unit e Otherwise it may cause explosion and a fire Safety Precautions Do not operate with wet hands or in damp environment e lt will cause electric shock HSITDNA Never touch the metal parts of the unit when removing the filter e They are sharp and may cause injury For inner cleaning contact an Authorized Service Center or a dealer Do not use harsh detergent that causes corrosion or damage on the unit Harsh detergent may also caus
23. IONS WHEN THE APPLIANCE WILL BE DISCONNECTED OFTEN Do not use an adapter plug in these situations Unplugging the power cord frequently can lead to an eventual breakage of the ground terminal The wall power outlet should be replaced by a three slot grounding outlet instead Mm Installation Remove packing sheet from the back of the sleeve and packing corner and blue tape from the air conditioner INSTALLATION REQUIREMENTS If you use an existing wall sleeve you should measure its dimensions Install the new air conditioner according to these installation instructions to achieve the best performance All wall sleeves used to mount the new air conditioner must be in good structural condition and have a rear grille to securely attach the new air conditioner Figure 1 With the LGE sleeve optionally supplied with your unit you can maintain the best performance of the new air conditioner Figure 2 Installation INSTALLATION HARDWARE wy AL eee POE eee ETA ets SELLA ZL LLL Me LOI LEIS LESS ELLIE ELLY i ZL leg atti EO 2 Size options ER LALA LEA A 2 Size options 19 213 23 499 mm Air Conditioner 3 EM NAME OF PARTS o lt PLASTIC GRILLE HORIZONTAL INSULATION STRIPS AROUND INSULATION STRIPS SUPPORT BLOCK BAFFLE TRIM FRAME SHIM ONO AGNO 2 NNDN 2 N DNiN 2 PLASTIC NUTS AND WASHER SCREWS
24. OR THE USER S PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three prong grounding plug Use this with a standard three slot grounding wall power outlet to minimize the hazard of electric shock The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded 10 Room Air Conditioner DO NOT CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER PLUG A SITUATIONS WHEN THE APPLIANCE WILL BE DISCONNECTED OCCASIONALLY Because of potential safety hazards we strongly discourage the use of an adapter plug However if you wish to use an adapter a TEMPORARY CONNECTION may be made Use UL listed adapter available from most local hardware stores The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection A CAUTION Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded Disconnect the power cord from the adapter using one hand on each Otherwise the adapter ground terminal might break DO NOT USE the appliance with a broken adapter plug B SITUAT
25. RANQUE En caso de fallo de la corriente el ctrica la unidad funcionar como antes cuando vuelve la corriente AHORRADOR DE ENEERGIA La unidad pasa de forma predeterminada al modo de Ahorro de Energ a cada vez que la unidad se enciende excepto al restaurarse despu s de una falla de la energ a el ctrica PRECAUTI N El mando a distancia no funcionar correctamente si una luz fuerte hace contacto con el sensor del aire acondicionado o si hay obs culos entre el mando a distancia y el aire acondicionado Insertar las bate 1 Empuje hacia afuera con su pulgar la cubierta en la parte posterior del control remoto 2 Preste atenci n a la polaridad e inserte dos nuevas bater a AAA 1 5V 3 Vuelva a colocar la cubierta CONSEJO No use bateria recargables Asegurese que ambas baterias sean nuevas No mezcle las pilas alcalinas estandares Carbon zinc o recargables Niquel cadmium e Para evitar que se descarguen quite las bater as del control remoto si el acondicionador de aire no va a ser usado por un per odo largo de tiempo Mantenga el control remoto lejos de los lugares h medos o extremadamente calientes Para mantener el funcionamiento ptimo del control remoto el sensor remoto no debe exponerse a la luz solar directa Manual del usuario 19 m u v gt Z O Instrucciones operativas Control de ventilaci n l Empuje la palanca hacia la posici n CLOSE cerrado para que el aire de la h
26. WARRANTY IS REQUIRED BY LAW THIS WARRANTY IS LIMITED IN DURATION TO THE TERM PERIOD EXPRESSED ABOVE REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY FOR THE CUSTOMER NEITHER THE MANUFACTURER NOR ITS U S DISTRIBUTOR SHALL BE LIABLE FOR ANY INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY NATURE INCLUDING AND WITHOUT LIMITATION TO LOST REVENUES OR PROFITS OR ANY OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE HOW TO OBTAIN WARRANTY SERVICE amp ADDITIONAL INFORMATION Call 1 800 243 0000 or visit our website at www lg com Mail to LG Customer Information Center ATTN CIC 201 James Record Road Huntsville AL 35824 Garant a GARANT A LIMITADA DEL AIRE ACONDICIONADO LG EE UU COBERTURA DE LA GARANT A LG Electronics Inc LG garantiza que reparar o sustituir gratuitamente su producto si resulta defectuoso en materiales o mano de obra bajo condiciones normales de uso durante el periodo de garant a mencionado m s abajo efectivo a partir de la fecha de compra del producto original por parte del consumidor Esta garant a limitada s lo es v lid
27. a e Son puntiagudas y pueden descarga el ctrica y da os provocar lesiones Para una limpieza interior p ngase en contacto con un Centro de Servicios Autorizado o un revendedor No utilice detergentes abrasivos que causan corrosi n o da an la unidad Los detergentes abrasivos pueden igualmente provocar un fallo del producto un incendio o una descarga electr nica APRECAUCION E Instalaci n Instale el producto de modo que el ruido o el aire caliente producido por la unidad externa no moleste a los vecinos Mantenga nivelado el producto al instalarlo e De lo contrario puede dar lugar a disputas vecinales e De lo contrario se podr a causar vibraciones o escapes de agua Manual del usuario 5 Safety Precautions E Operaci n No ponga plantas ni animales en la trayectoria que recorrer el aire caliente e Podr a ocasionar lesiones el aparato No se suba a la unidad interior exterior ni coloque objetos sobre la misma e Puede lesionarse al caerse del aparato o al caerse los objetos que haya colocado Tenga cuidado para no tocar los bordes puntiagudos al instalar ocasiones e Podr a ocasionar lesiones su salud Si entra l quido de las pilas en contacto con la piel o la ropa l vela inmediatamente con agua No utilice el control remoto si las pilas tienen fugas Los productos qu micos de las pilas podr an ee causar quemaduras u D otros perjuicios a la salud
28. a para el comprador original del producto y no es asignable ni transferible a ning n otro comprador o usuario final subsecuentes y efectiva nicamente cuando el producto se compra a trav s de un distribuidor autorizado de LG y se utiliza en los Estados Unidos EE UU o en cualquiera de sus territorios Nota Los recambios y piezas de repuesto pueden ser nuevos o estar reconstruidos de f brica y est n garantizados durante el tiempo restante del periodo de garant a de la unidad original o noventa d as 90 el periodo de los dos que sea m s largo Por favor guarde el recibo de compra o la nota de entrega como prueba de la fecha de compra como comprobante de garant a se le puede pedir que presente una copia a LG o a su representante autorizado PERIODO DE GARANT A 1 a o desde la fecha de compra Cualquier repuesto interno funcional y mano de obra PROCESO DE SERVICIO Servicio a domicilio Los servicios a domicilio se prestar n durante el periodo de garant a sujeto a disponibilidad en los Estados Unidos El servicio a domicilio puede no estar disponible en todas las reas Para recibir asistencia t cnica a domicilio el producto debe estar en un entorno despejado y accesible al personal t cnico Si durante el servicio a domicilio la reparaci n no se puede llevar a cabo es posible que sea necesario desplazarlo a nuestras instalaciones repararlo y devolverlo a su hogar Si este fuera el caso LG puede optar a petici n nuestra a
29. abitaci n se caliente se enfr e o simplemente recircule Empuje la palanca hacia la posici n OPEN abierto para expulsar el humo o el aire estancado de la habitaci n Obtendr el m ximo rendimiento de esta funci n si se utiliza junto con la posici n FAN ONLY s lo ventilador PULL OPEN PUSH CLOSE Direcci n del aire l Se puede controlar la direcci n del aire ajustando las persianas horizontales y verticales e AJUSTE DE LA DIRECCI N e AJUSTE DE LA DIRECCI N HORIZONTAL DEL AIRE VERTICAL DEL AIRE La direcci n horizontal del aire se ajusta La direcci n vertical del aire se ajusta moviendo la persiana vertical La palanca de moviendo las persianas horizontales la persiana vertical se ubica a la derecha y a la izquierda de la descarga de aire 20 Aire Acondicionado Cuidado y Mantenimiento W Cuidado y Mantenimiento APAGUE EL ACONDICIONADOR DE AIRE Y DESENCH FELO DE LA FUENTE DE PODER Limpieza del filtro de aire El filtro de aire debe ser controlado al menos dos veces al mes para ver si es necesaria su limpieza Las part culas atrapadas en el filtro pueden acumularse y bloquear el flujo del aire Esto reduce la capacidad de refrigeraci n y tambi n causa una acumulaci n de hielo en los sepentines de enfriamiento Si el filtro se inutiliza o se da a debe ser reemplazado inmediatamente Filtros de repuesto est n disponibles en la tienda donde lo compr el representante y en los cent
30. and drains into base pan little humidity normal for a longer period in very humid areas Air conditioner Dirty air filter air restricted Clean air filter turns on and Outside temperature SetFAN speed to a faster setting to bring air ff idi Outside temperature Set FAN speed to a faster setting to bring air ont rapidly extremely hot through cooling coils more frequently y Noise when Air movement sound _____ This is normal If too loud set to lower FAN setting unit is cooling Window vibration poor Refer to installation instructions or check with installation installer Remote Remote control not located Place remote control within 20 feet amp 120 radius Sensing within range of the front of the unit Deactivating Remote control signal Remove obstruction Prematurely obstructed Room too Set temperature too low Increase set temperature cold If you see CH in the display please call 1 800 243 0000 Owner s Manual 23 Aire Acondicionado Manual del usuario TABLA DE CONTENIDOS Y PARA SUS ARCHIVOS Precauciones de seguridad 3 Escriba aqu el modelo y n mero de serie Modelo n Antes de la Operaci n 7 Serie n Puede encontrar estos datos en la etiqueta situada en el lateral de Introduccion 8 cada unidad Nombre del distribuidor Seguridad el ctrica 9 Techa de compra E Adjunte su recibo a esta p gina con
31. and stops when you press the button again 2 FAN SPEED SELECTOR Use to set the fan speed to Low F1 High F2 3 ON OFF TIMER Delay ON when the air conditioner is off it can be set to automatically turn on from 1 to 24 hours at its previous mode and fan settings Delay OFF when the air conditioner is on it can be set to automatically turn off from 1 to 24 hours 4 OPERATION MODE SELECTOR Push the MODE button to rotate between Energy Saver Cool Fan Heat Energy Saver The fan stops when the compressor stops cooling Approximately every 3 minutes the fan will turn on and check the room air temperature if cooling is needed Cool Compressor runs and cools the room Use the A V and FAN buttons to set the desired temperature and circulation fan speed Fan Fan circulates air but compressor does not run Use the FAN button to set the desired fan speed 18 Room Air Conditioner Operating Instructions Heat Fan runs continually for normal heating operation 5 TEMPERATURE CONTROL The thermostat monitors room temperature to maintain the desired temperature The thermostat can be set between 60 F 86 F 16 C 30 C 6 REMOTE CONTROL SENSOR 7 CLEAN FILTER Clean Filter LED will light up to notify you that your filter needs to be cleaned m Z a 5 7 After cleaning the filter press Temp AV together to turn off Clean Filter light Filter reset must be done from unit con
32. ble electric shock 3 When cleaning the unit first make sure that the power and breaker are turned off The fan rotates at a very high speed during operation There is a possibility of injury if the unit s power is accidentally triggered on while cleaning inner parts of the unit Service For repair and maintenance contact an Authorized Service Center See the warranty page for details or call 800 243 0000 Have your model number and serial number available They should be written on page 2 of this manual Owner s Manual 7 Introduction Symbols Used in this Manual A This symbol alerts you to the risk of electric shock This symbol alerts you to hazards that could cause harm to A the air conditioner hoji 9 This symbol indicates special notes Features A WARNING This appliance should be installed in accordance with the National Electric Code THE SLEEVE AND THE REAR GRILLE optionally supplied with your unit SLEEVE ASSEMBLY Including Aluminum Rear grille REAR GRILLE Aluminum Rear grille THE UNIT Lee VERTICAL AIR CSRS Horizontal Z SS AIR DISCHARGE AIR FILTER S lt IR WSN Fa CABINET INLET GRILLE N Air Intake Electric Heater FRONT GRILLE HORIZONTAL AIR DEFLECTOR Vertical Louver VENT CONTROL 8 Room Air Conditioner Electrical Safety E Electrical Safety Power cord may include a current interrupter device A test and reset button is provided on th
33. correction of house wiring or plumbing or correction of workmanship and is reported to LG within seven 7 product installation calendar days from the date of delivery 3 Damage or failure caused by leaky broken frozen water 9 Damage or missing items to any display open box pipes restricted drain lines inadequate or interrupted discounted or refurbished product water supply or inadequate supply of air 10 Product where the original factory serial numbers have 4 Damage or failure caused by accidents pests and vermin been removed defaced or changed in any way lightning wind fire floods or acts of God 11 Repairs when product is used in other than normal and 5 Damage or failure resulting from misuse abuse improper usual household use e g rental commercial use installation repair or maintenance Improper repair offices or recreational facilities or contrary to the includes use of parts not approved or specified by LG instructions outlined in the owner s manual 6 Damage or failure caused by unauthorized modification or 12 The removal and reinstallation of the Product if it is alteration to the product installed in an inaccessible location 7 Damage or failure caused by incorrect electrical current voltage or plumbing codes THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING AND WITHOUT LIMITATION TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT ANY IMPLIED
34. damente c lida conseguir que el aire circule m s r pidamente por el circuito refrigerador Se escuchan Suena el movimiento del aire Esto es normal Si est muy fuerte ajuste el FAN ruidos cuando el A _ ventilador a una velocidad m s baja ______________ equipo est Vibraci n de la ventana instalaci n Consulte las instrucciones de montaje o al instalador operando defectuosa El sensor remoto El control remoto no est en el rango Ubique el control remoto dentro de un rango de 20 pies y se desactiva de de alcance en un ngulo de 120 desde el frontal de la unidad manera prematura La se al del control remoto est Remueva la obstrucci n obstruida Estancia La temperatura est demasiado baja Seleccione una temperatura m s alta demasiado fr a Si aparece CH en la pantalla por favor llame al 1 800 243 0000 Manual del Propietario 23 WARRANTY LG ROOM AIR CONDITIONER LIMITED WARRANTY USA WHAT THIS WARRANTY COVERS LG Electronics U S A Inc LG warrants your LG Room Air Conditioner product against defect in materials or workmanship under normal household use during the warranty period set forth below LG will at its option repair or replace the product This limited warranty is valid only to the original retail purchaser of the product is not assignable or transferrable to any subsequent purchaser or user and applies only when the product is purchased through an LG authorized dealer or distribu
35. e failure of product fire or electric shock CAUTION E Installation Install the product so the exhaust and noise are not aimed directly at the neighbors e Be considerate Follow installation instructions exactly e Otherwise it may cause vibration or water leakage Owner s Manual 5 Safety Precautions E Operation Do not use this appliance for Do not block the inlet or Use a soft cloth to clean Do special purposes such as outlet of air flow not use wax thinner or a cooling pets foods precision strong detergent machinery or objects of art e It is an air conditioner not a e lt may cause product failure e The appearance of the air precision refrigeration system conditioner may deteriorate change color or develop surface flaws Do not step on the Always insert the filter Do not drink water drained indoor outdoor unit and do securely from air conditioner not put anything on it Clean it every two weeks e It may cause an injury e Operation without filters will e It contains containments and through dropping of the unit cause failure will make you sick or falling down lt Be cautious not to touch the Instead of running air conditioning Do not insert the hands or sharp edges when constantly open a window bars through the air inlet or installing for fresh air occasionally outlet during operation e It may cause injury e You will feel better e Otherwise it may cause personal inju
36. e plug case The device should be tested on a periodic basis by first pressing the TEST button and then the m Z a un E RESET button If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician NOTICE A WARNING Never push the test button during operation Otherwise this plug can damaged Use 20 AMP time Do not remove modify or immerse delay fuse or 20 AMP circuit breaker this plug Standard 250V 3 wire groundin 7 i receptacle rated 20A Seay AC If this device trips the cause should be corrected before further use A WARNING A CAUTION USE OF EXTENSION CORDS The conductors inside this cord are RISK OF FIRE could cause serious injury or death surrounded by shields which monitor DO NOT use an extension cord with this window leakage current air conditioner These shields are not grounded DO NOT use surge protectors or multi outlet Periodically examine the cord for any adapters with this window air conditioner damage Do not use this product in the event the shields become exposed Avoid shock hazard This unit cannot be user serviced Do NOT open the tamper resistant sealed portion All warranties and performance will be voided This unit is not intended to be used as an ON OFF switch Owner s Manual 9 Electrical Safety Electrical Safety IMPORTANT PLEASE READ CAREFULLY F
37. el alojamiento a la pared Vuelva a pintar el alojamiento si fuera necesario B Prepare el alojamiento de pared para la instalaci n de la unidad Si pretende utilizar una caja de pared de la que ya dispone y no es LGE utilice el procedimiento B o C que se muestra a continuaci n Procedimiento Marca Profundidad A LGE 42 44 16 23 32 White Westin Fig Carer 054 444505508 16 17 1 2 o 22 52F series B General Electric 42 87 16 718 Hotpoint Whirlpool 43 5 0 58 42 17 1 8 o 23 Carrier 51S series 47 29 18 5 8 Fedders Emerson 42 54 0 50 16 16 3 4 o 19 3 4 Cc Emerson Fedders 38 1 15 Friedrich 42 54 16 3 4 g Instale la nueva unidad en el gabinete de pared A PRECAUCION Una vez finalizada la instalaci n la unidad de repuesto DEBE tener una pendiente hacia atr s como la que se muestra Para alcanzar una pendiente del 1 4 retire la parte posterior de las bandas de cu a de 11 13 16 y ac plelas seg n se muestra a continuaci n en la fig 3 Coloque la parte m s alta de la cu a en la parte frontal del pilar en la base del gabinete de pared 3 4 de alto Gabinete de pared UNIDAD COLOCACI N DE LA CU A INSTALACI N DE LA UNIDAD Figure 3 Instalaci n PROCEDIMIENTO A Si est utilizando la nueva funda suministrada opcionalmente con su unidad vaya directamente al paso 3 En caso contrario instale la rejilla p
38. el cable de alimentaci n cerca gas inflamable o materiales combustibles tales como la gasolina benceno disolvente etc e Puede ocasionar una explosi n o descarga el ctrica No comparta el tomacorriente con otros electrodom sticos e De lo contrario puede provocar debido a la generaci n de calor No ponga el cable de alimentaci n cerca de un calentador No permita que entre agua en las piezas el ctricas e Puede ocasionar un incendio y una descarga el ctrica Puede provocar fallos en el producto o descargas el ctricas Desenchufe la unidad si oye un sonido extra o olores o si observa salir humo e De lo contrario puede ocurrir un incendio y un accidente por descarga el ctrica No abra la parrilla de est en funcionamiento descargas el ctricas y fallos Ventile bien la sala al usar este aparato con una estufa etc Apague el aparato y el interruptor diferencial primero antes de limpiar la unidad e Debido a que el ventilador gira a alta velocidad durante el funcionamiento podr a ocasionar lesiones e Puede ocurrir un falta de 4 Aire Acondicionado una descarga el ctrica o incendio entrada al aparato mientras e De lo contrario pueden ocurrir Saque el enchufe en caso de necesidad sosteniendo la cabeza del enchufe y no lo toque con las manos mojadas e De lo contrario podr a provocar un incendio o descarga el ctrica Oo Cs 19
39. ente el ctrica 6 Si cuerda tap n se da a reemplace s lo con una parte autorizada m un v gt O Uso 1 Estar expuesto al flujo directo de aire por un per odo largo de tiempo puede constituir un riesgo para su salud No exponga a las personas mascotas o plantas al flujo directo por per odos largos de tiempo 2 Debido a la posibilidad de una deficiencia de ox geno ventile la habitaci n cuando utilice al mismo tiempo estufas u otros aparatos de calefacci n 3 No use este acondicionador de aire para prop sitos determinados no especificados por ej preservar dispositivos de precisi n alimentos cachorros plantas y objetos de arte Usarlo de esta manera puede da ar tales elementos Limpieza y mantenimiento 1 No use agua para limpiar adentro del acondicionador La exposici n al agua puede destruir la aislaci n y esto a su vez provocar una descarga el ctrica 2 Cuando limpie la unidad aseg rese que la corriente y el interruptor est n desconectados El ventilador gira a muy alta velocidad cuando est funcionando Existe la posibilidad de lesionarse si la energ a se conecta accidentalmente cuando est limpiando las piezas internas de la unidad Servicio Para reparaciones y mantenimiento p ngase en contacto con un centro de servicio autorizado Consulte la p gina de garant a o llame al n mero 800 243 0000 Tenga su n meor d emodelo y n mero de serie a mano Los encontrar en la p g
40. ey a RN Utilice un pa o suave para limpiar No utilice cera disolventes o detergentes fuertes e La apariencia del aparato de aire acondicionado puede deteriorar cambiar el color o desarrollar flujos en las superficies Jo lt j l w El Si entra agua en el producto apague el interruptor de la carcasa principal del aparato P ngase en contacto con el centro de servicio despu s de haber sacado el enchufe del tomacorriente g B ul eN EGO Apague el interruptor de alimentaci n principal cuando no vaya a utilizar el aparato durante mucho tiempo e Evitar el arranque accidental y la posibilidad de lesiones Precauciones de seguridad No opere ni detenga la unidad insertando o estirando de enchufe No da e ni use un enchufe No toque el producto con de alimentaci n no las manos mojadas o en un ambiente h medo e Provocar descargas el ctricas especificado e Provocar descargas el ctricas o incendios 108 O e De lo contrario puede provocar una descarga el ctrica o incendio debido a la generaci n de calor pe 6 E BO VQ Cv UN Sostenga el enchufe por su Cuando haya un escape de cabeza al sacarlo gas abra la ventana para ventilar antes de poner en marcha la unidad e De lo contrario podr a ocurrir una explosi n o incendio No toque las partes met licas del aparato al sacar el filtro del aire TONVdS4 e Podr a ocasionar un
41. g from the support blocks and attach them to the inside of the wall sleeve as shown in Figure 13 Slide the baffle into slots of the support blocks 7 546 Sleeve Support Block Figure 13 Install the new unit into the wall sleeve 8 To assemble trim snap the tab of each piece into the slot of the other piece as shown below Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below Aa Trim 2 ea a Figure 14 Installation 44 CAUTION e Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit e When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils e Make sure air conditioner does not fall during removal HSITDNA Owner s Manual 15 Installation PROCEDURE C Redirect the louvers at the back of the wall sleeve to 60 angle as shown in the Figure 15 The use of pliers is recommended 7 1346 60 Aso Rear Louvers Top View Figure 15 2 If the wall sleeve already has a rear grille skip to step 4 If the wall sleeve does not have a rear grille or louvered panel install the plastic grille from the kit Cut the plastic grille to 26 1 2 wide and 15 1 2 high Place the plast
42. ic grille to the inside of the wall sleeve at the rear flange Ree EE ee Place the plastic grille Figure 16 Fasten the 4 washer screws to secure the grille to the wall sleeve If you need plastic nuts to mount plastic grille to the inside of the wall sleeve there are plastic nuts in the installation kit The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges Fasten the screws Figure 17 Remove the backing from the Horizontal Insulation strip 19 8 x 13 g x 273 16 and attach that to the inside bottom of the sleeve as shown below Remove the backing from the Around Insulation strip 13 8 x 13 g x 61 o and attach that to the inside front of the sleeve as shown below Figure 18 16 Room Air Conditioner B If the depth of your existing sleeve is less than or equal to 18 skip to step 7 Otherwise cut the baffles and the support blocks according to Length A in the table below Depth D of the existing Length A A wall sleeve inches inches D Support 18 lt D lt 18 5 s 3 4 ral Block 18 s lt D lt 19 3 4 1 5 4 Baffle 19 9 4 lt D lt 22 4 ye 19 16 Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 20 Slide the baffle into slots of the support blocks 7 1356
43. idad puede vibrar y hacer al refrigerante pasando a trav s ruido debido a una estructura d bil del evaporador durante una de la pared o la ventana o a una normal operaci n instalaci n incorrecta 22 Aire Acondicionador Mantenimiento y servici Resoluci n de problemas El acondicionador de aire puede estar funcionando anormalmente cuando El aire El aire acondicionado est Asegurese q e ei aire acondicionado est conectado acondiciona do desconectado completamente a la fuente de energia no enciende El fusible esta quemado el interruptor Cheque los fusibles interruptor de la casa y reemplace de energ a se habloqueado los fusibles o reestablezca el interruptor de energi Falta de energ a 7 Cuando la energi se reestablezca espere 3 minutos para encender de nuevo el aire acondicionado Con esto vitara que se produzca una sobrecarga en el compresor El dispositivo interruptor de corriente Presione el bot n RESET situado en el enchufe del cable est desconectado de alimentaci n Si el bot n RESET no p ermanece activo suspenda el uso del aure acondicionado y pongase en contacto con un t cnico de servicio cualificado El aire El flujo de aire esta restringido Aseg rese que no haya cortinas persianas o muebles acondiciona do no bloqueando el frente del aire acondicionado enfr a corno pa ee A ree debiera Coloque el control de TEMPERATURA Ajustar el control de temperatura a un n mero m s bajo
44. igue enfriando Aporximadamente cada 3minutos el ventilador se encender y necesitara verificar la temperatura del cuarto para saber si es necesario mas enfriamiento Cool fr o El compresor funciona y enfr a la habitaci n Use los botones TEMP TIMER A V y FAN ventilador para configurar la temperatura deseada y la velocidad de circulaci n del ventilador 18 Aire Acondicionado Instrucciones operativas FAN ventilador El ventilador hace circular el aire pero el compresor no funciona no funciona Utilice el bot n FAN ventilador para configurar la velocidad deseada del ventilador HEAT CALENTAR El calentar funciona y calentar la habitaci n 5 CONTROL DE TEMPERATURA El termostato monitorea la temperature de la habitaci n para mantener la temperatura deseada El termostato puede ser colocado entre 60 F 86 F 16 C 30 C 6 SENSOR DEL CONTROL REMOTO D LIMPIEZA DEL FILTRO El LED Clean Filter Limpiar filtro se iluminar para avisarle que hay que limpiar el filtro Despu s de limpiar el filtro pulse simult neamente los botones TempAV para apagar la luz Clean Filter El reinicio del filtro debe hacerse desde el panel de control de la unidad no desde el mando a distancia CONSEJO Esta funcionalidad es un recordatorio para limpiar el Filtro de Aire Consulte Mantenimiento para un funcionamiento m s eficiente La luz LED se iluminar despu s de 250 horas de funcionamiento AUTO AR
45. ina 2 de este manual Manual del usuario 7 Introducci n S mbolos Utilizados en Este Manual A A corriente el ctrica da o del ventliador Este s mbolo lo advierte de un peligro de accidente por Este s mbolo lo adiverte de un peligro que pueda causar un 0 E A 0 Este s mbolo significa condicciones especiales Caracter sticas A ADVERTENCIA Este aparato deber a instalarse de acuerdo con las normas del C digo El ctrico Nacional EL UNIDAD DEFLECTOR VERTICAL DE AIRE Rejilla de ventilaci n horizontal EL SOPORTE DE PARED Y LA REJILLA POSTERIOR incluido opcionalmente con su unidad MONTAJE DEL SOPORTE DE PARED Incluyendo rejilla posterior de aluminio REJILLA POSTERIOR Rejilla posterior de aluminio DESCARGA S DEFLECTOR HORIZONTAL DE AIRE Rejilla de ventilaci n vertical REJILLA DE ENTRADA Toma de aire CONTROL DEL ORIFIC 8 Aire Acondicionado DE AIRE B ARMARIO REJILLA FRONTAL O DE VENTILACI N Seguraida Electrica E Seguraida Electrica CONSEJO Utilice el enchufe de la pared Consumo de Energ a Utilice un fusible de 20AMP o un Interruptor de 20AMP Standard 250V enchufe de 3 L neas de 20A 250V AC A ADVERTENCIA USO DE PROLONGADORES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protecto
46. ire due to heat generation Do not disassemble or Be caution when unpacking Do not store flammables like modify products and installing gasoline benzene thinner etc near the air conditioner e It may cause failure and e Sharp edges may cause 7 It may cause explosion or electric shock injury fire Owner s Manual 3 Safety Precautions E Operation Do not place heavy object on the power cord and take care so that the cord should not be pressed e There is danger of fire or electric shock Do not place the power cord near a heater e It may cause fire and electric Unplug the unit if strange sounds odors or smoke come from it e Otherwise it may cause fire and electric shock accident V No correlation between fan usage and oxygen depletion e An oxygen shortage may occur 4 Room Air Conditioner Do not share the outlet with Take the power plug out if other appliances necessary holding the head of the plug and do not touch it with wet hands e Otherwise it may cause a fire or electrical shock e It will cause electric shock or fire due to heat generation gt E a AR a O Atl Use a soft cloth to clean Do not use wax thinner or a strong detergent e The appearance of the air conditioner may deteriorate change color or develop surface flaws Do not allow water to run into electric parts e It will cause failure of machine or electric shock
47. l stica del equipo Corte la rejilla de pl stico a 64 77 cm 25 1 2 de ancho y 38 74 cm 15 1 4 de alto Coloque la rejilla de pl stico en el interior del alojamiento de pared en el flanco posterior SS ee Sateen DS Figure 4 A Apriete los 4 tornillos de arandela para fijar la rejilla al alojamiento de pared Si necesita tuercas de pl stico para montar la rejilla de pl stico en el interior del alojamiento hay tuercas de pl stico en el equipo de instalaci n Las tuercas se instalan desde el interior del alojamiento y se introducen apret ndolas en los orificios cuadrados de los flancos traseros Figure 5 Extraiga la parte posterior de la tira de Aislamiento horizontal de 3 5 x 0 96 x 69 06 cm 13 s x 3 5 x 273 16 y fijela a la parte inferior interna del alojamiento seg n se muestra abajo Extraiga la parte posterior de la tira de Aislamiento lateral de 3 5 x 1 9 x 156 21 cm 13 8 x 3 4 x 611 2 y fijela al interior del alojamiento seg n se muestra abajo LS seen DR DS SOES ze es Be SES 0 SS Ls SS 3 Z os SS SS XIRI SS een gases eS SS 2 eS SS 5 Figure 6 14 Instale la nueva unidad en el alojamiento de la pared Para montar el reborde inserte el saliente de cada pieza en la ranura de la otra pieza seg n se muestra abajo Deslice el reborde sobre la parte frontal del aparato de aire acondicionado ha
48. ligro de peso excesivo Se necesitan dos o m s personas para mover e instalar la unidad Para evitar heridas o problemas musculares utilice t cnicas adecuadas para elevar y desplazar la unidad Al manejar el aparato de aire acondicionado tenga cuidado de evitar cortes de las aletas afiladas de metal en las bobinas frontal y trasera Aseg rese de que el aparato de aire acondicionado no cae al suelo durante la instalaci n m u 5 gt Z le Manual del usuario 17 Instrucciones operativas 1 ae MA eye He 98 Filter Reset Fan 2 ER ee TEMP WY Ne 5 3 IO S 4 FAN MODE TIMER SPEED POWER e e e ae De pee D POWER El funcionamiento se inicia cuando se pulsa esta tecla y se detiene cuando se la presiona nuevamente 2 SELECTOR DE VELOCIDAD DEL VENTILADOP Usado para ajustar la velocidad del ventilador a Low F1 High F2 8 CRON METRO ON OFF Encendido Cuando el acondicionador de aire esta apagado puede ajustarse para que se encienda automaticamente dentro de 1 a 24 horas en el nivel previo Apagado Cuando el acondicionador de aire esta apagado puede ajustarse para que se apague automaticamente dentro de 1 a 24 horas 4 FUNCIONAMIENTO DEL MODO SELECTOR Pulse el bot n MODE Modo para desplazarse entre Ahorro de Energ a Fr o Ventilador calentar Energy Saver Ahorro de Energ a El ventilador se detiene cuando el compressor no s
49. n la parte posterior de la ilustraci n del alojamiento de pared Se recomienda el uso de tenazas Si NO ajusta la direcci n corre el riesgo de un rendimiento pobre o de fallo del producto Este hecho no est cubierto bajo los t rminos de la garant a de Comfort Aire e Si decide mantener el alojamiento de pared existente tendr que ajustar la direcci n de la rejilla en la parte posterior de la ilustraci n del alojamiento de pared Se recomienda el uso de tenazas Si NO ajusta la direcci n corre el riesgo de un rendimiento pobre o de fallo del producto Este hecho no est cubierto bajo los t rminos de la garant a de LGE ART CULOS EN EL EQUIPO DE INSTALACI N Puede que no necesite todas las partes del equipo de instalaci n Tire las piezas que no utilice ART CULO Cantidad Rejilla de pl stico 3 81 x 2 54 x 210 03 cm 26 x 161 2 1 Tiras de aislamiento horizontal 91 52 x 69 03 om 1 xs x 27 1 3 5 X 3 5 x 69 03 cm 13 8 x 1 x 2755 1 Ti 3 5 x 2 03 x 153 035 1 x 5 4 x 61 2 1 iras de aislamiento lateral 3 5 x 3 5 x 153 035 19 8 x 15 2 x 611 2 1 Bloque de soporte 8 89 x 3 5 x 10 94 cm 15 4 x 15 6 x 45 5 2 Deflector 35 56 x 11 43 x 0 33 14 x 41 2 x e 1 Calzo para ajuste 33 02 x 2 54 x 2 03 13 x 1 x 5 4 2 Bastidor de reborde 2 Tornillo de arandela 4 Tuercas pl stico 4 Parte posterior de la rejilla 1 C MO INSTALARLO Identifique el alojamient
50. o existente en la pared antes de instalar la unidad de la lista que se muestra a continuaci n Medidas del alojamiento de la pared Marca pulgadas y cent metros Anchura Altura Profundidad wee 64 77 38 73 40 84 4 45 55 88 Carrier Serie 52F 25 1 2 15 14 16 17 1 2 General Electric Hotpoint 66 04 26 39 70 15 5 8 42 87 16 7 8 43 51 0 58 42 Whirlpool p 65 48 25 7 8 41 91 16 1 2 454 8 o 23 42 54 0 50 16 Fedders Emerson 68 58 27 42 54 16 3 4 16 314 0 19 314 LGE 65 73 25 7 8 39 44 15 17 32 42 46 16 23 32 Emerson Fedders 67 94 26 3 4 40 15 3 4 38 1 15 Carrier Serie 51S 65 40 25 3 4 42 87 16 7 8 47 32 18 5 8 Friedrich 68 58 27 42 54 16 3 4 42 54 16 3 4 12 Aire Acondicionado CONSEJO Todos los alojamientos de pared utilizados para montar el nuevo aparato de aire acondicionado deben estar en buenas condiciones estructurales y tener una rejilla posterior que se una con seguridad al alojamiento o un flanco posterior que sirva de tope al aparato de aire acondicionado a Extraiga el antiguo aparato de aire acondicionado del alojamiento de pared ya existente E Limpie el interior del alojamiento de pared ya existente No toque los sellados a El alojamiento de pared debe estar bien fijado a la pared antes de instalar el aparato de aire acondicionado Si fuera necesario utilice los clavos o tornillos para fijar
51. onalmente 2 opciones de tama o Z con su unidad mantener el mejor rendimiento del nuevo aire acondicionado FIG 2 ART CULO NOMBRE DE LAS PIEZAS CANTIDAD Ea 19 290 AN REJILLA DE PL STICO 1 499 mm TIRAS DE AISLAMIENTO HORIZONTAL TIRAS DE AISLAMIENTO LATERAL BLOQUE DE SOPORTE DEFLECTOR BASTIDOR DE REBORDE CALZO PARA AJUSTE TUERCAS DE PL STICO Y TORNILLOS DE ARANDELA Oes 41 Aparato de aire acondicionado yS Figure 1 A PRECAUCION Para evitar peligro de heridas personales da os a la propiedad o al producto debido al peso de este aparato y a los bordes afilados que pueden estar expuestos 45 72 Los aparatos de aire acondicionado de los que trata este manual 394 mm constituyen un peligro de peso excesivo Se necesitan dos o m s personas para mover e instalar la unidad Para evitar heridas o problemas musculares utilice t cnicas adecuadas para elevar y Kar desplazar la unidad 425 mm Revise cuidadosamente la ubicaci n donde se instalar el aparato de Alojamiento de pared LGE Figure 2 aire acondicionado Aseg rese de que puede soportar el peso de la Rejilla de metal de aluminio foraminado unidad durante un periodo de tiempo prolongado Maneje con cuidado el aparato de aire acondicionado Lleve guantes SERVICIO EL CTRICO protectores siempre que levante o desplace la unidad EVITE las aletas Compruebe el servicio el ctrico disponible La
52. res contra picos de tensi n ni adaptadores para m ltiples tomacorrientes con este Acondicionador de Aire de Ventana El cable de alimentaci n puede incluir un dispositivo interruptor de corriente La carcasa del enchufe cuenta con un bot n de prueba y otro de reinicio El dispositivo debe comprobarse peri dicamente presionando primero el bot n TEST y despu s RESET Si el bot n TEST no se desconecta o si el bot n RESET no permanece activo suspenda el uso del aire acondicionado y p ngase en contacto con un t cnico de servicio cualificado A ADVERTENCIA No presione nunca el bot n de prueba durante el funcionamiento de lo contrario el enchufe podr a resultar da ado No desmonte modifique ni sumerja en agua este enchufe Si el dispositivo se activara deber corregir la causa antes de volver a utilizarlo A PRECAUCION Los hilos conductores dentro del cable est n rodeados por blindajes que supervisan la corriente de fuga Estos blindajes no est n puestos a tierra Examine peri dicamente el cable en busca de cualquier da o No utilice este producto si los blindajes resultaran expuestos Evite el riesgo de descargas el ctricas esta unidad no puede ser reparada por el usuario por ser resistente y a prueba de alteraciones Manipular la porci n sellada de la unidad anular todas las garant as y quejas de rendimiento Esta unidad no est dise ada para su uso como un interruptor de encendido apagado
53. ros de servicios autorizados m u U gt O 1 Abra la rejilla de entrada hacia abajo tirando de la parte superior de la rejilla de entrada 2 Quite el filtro de aire de la rejilla frontal tirando ligeramente del filtro de aire 3 Lave el filtro usando agua tibia por debajo de 40 C 104 F 4 Sacuda suavemente el exceso de agua del filtro Reemplace el filtro Como agregar la rejilla frontal al gabir La rejilla frontal puede quitarse para su limpieza o para comprobar el modelo y el n mero de serie Para su seguridad debe seguir el siguiente procedimiento para colocarla 1 Quite la parte superior de la rejilla frontalde 3 Abra la rejilla de entrada la parte superior del gabinete 4 Ajuste los tornillos a trav s de la rejilla frontal 2 Empuje los extremos frontales de la rejilla en la placa de la caja de control hacia el gabinete a fin de insertar las gt ki 5 Cierre la rejilla de entrada pesta as de la rejilla frontal en el gabinete MAZ Guie la palanca cuidadosamente a trav s de la parrilla mientras la empuja Manual del usuario 21 Mantenimiento y servicio Problemas y Soluciones habit Antes de Llamar el Servicio de Asistencia T cnica Si tiene problemas con su ventilador lea las informaciones siguientes y trate de resolver el problema Si no puede encontrar la soluci n desconecte el ventilador y dir jase a 1 800 243 000 El ventilador no funciona 1 Compruebe que el ven
54. ry i If the liquid from the battery gets onto your skin If you eat the liquid from the battery brush or clothers wash it well with clean water Do your teeth and see doctor Do not use the not use the remote if the battery has leaked remote if the battery have leaked The chemicals in battery could cause burns or The chemicals in battery could cause burns or other health hazards Er other health hazards o D get 6 Room Air Conditioner Before Operation m Z 9 77 I Preparing for Operation Contact an installation specialist for installation Plug in the power plug properly Use a dedicated circuit Do not use an extension cord Do not start stop operation by plugging unplugging the power cord If the cord plug is damaged replace it with only an authorized replacement part OORUN Usage 1 Being exposed to direct airflow for an extended period of time could be hazardous to your health 2 No correlation between fan usage and oxygen depletion 3 Do not use this air conditioner for non specified special purposes e g preserving precision devices food pets plants and art objects Such usage could damage the items Cleaning and Maintenance 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possi
55. sta que el reborde est unido a pa o con el alojamiento seg n se muestra a continuaci n In m u V gt Z lo Adorno 2ea Figure 7 A PRECAUCION Los aparatos de aire acondicionado de los que trata este manual constituyen un peligro de peso excesivo Se necesitan dos o m s personas para mover e instalar la unidad Para evitar heridas o problemas musculares utilice t cnicas adecuadas para elevar y desplazar la unidad Al manejar el aparato de aire acondicionado tenga cuidado de evitar cortes de las aletas afiladas de metal en las bobinas frontal y trasera Aseg rese de que el aparato de aire acondicionado no se cae durante la instalaci n Manual del usuario 13 Instalaci n PROCEDIMIENTO B 14 Coloque la direcci n de la rejilla en la parte posterior del alojamiento de la pared en un ngulo de 60 seg n se muestra en la FIG 8 Se recomienda el uso de tenazas a Extraiga la parte posterior de la tira de Aislamiento horizontal de 3 5 x 1 60 x 69 06 cm 13 8 x 5 8 x 273 16 y fijela a la parte inferior interna del alojamiento seg n se muestra abajo Extraiga la parte posterior de la tira de Aislamiento lateral de 3 5 x 1 9 x 156 21 13 8 x 3 4 x 611 2 y fijela al interior del alojamiento seg n se muestra abajo 19 84 cm 7 516 Rejilla posterior Vista superior Figure 8 A Si el alojamiento de pared est ya equipado con una rejilla trasera
56. stalled from the inside of the sleeve and are pressed into the square holes of the rear flanges Figure 5 E Remove the backing from the horizontal insulation strip 13 g x 37g x 27346 and attach that to the inside bottom of the sleeve as shown below Remove the backing from the around insulation strip 13 g x 34 x 611 2 and attach that to the inside front of the sleeve as shown below HSITDNA y WIJS Figure 7 Figure 6 44 CAUTION Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils Make sure air conditioner does not fall during removal Owner s Manual 13 Installation PROCEDURE B Redirect the louvers at the back of the wall sleeve to 60 angle as shown in Figure 8 The use of pliers is recommended 7 Sne vA KILLA Rear Louvers Top View Figure 8 A If the wall sleeve already has a rear grille skip to step 4 If the wall sleeve does not have a rear grille or louvered panel install the plastic grille from the kit Cut the plastic grille to 25 1 2 wide and 15 1 4 high Place the plastic grille to the inside of
57. tas instrucciones est n seguirse B Una operaci n incorrecta por ignorar las instrucciones provocar lesiones o da os La seriedad se clasifica por las siguientes indicaciones F ADVERTENCIA Este s mbolo indica la posibilidad de muerte o de seria lesi n A PRECAUCION Este s mbolo indica s lo la posibilidad de lesiones o da os a la propiedad so y E Significados de los s mbolos utilizados en este manual 7 amp No hacer Q Siga estas instrucciones TONVdS4 ADVERTENCIA E Instalaci n No utilice un cable de Enchufe siempre a un No modifique ni alargue el alimentaci n enchufe o una tomacorriente que tenga cable de alimentaci n toma suelta que est da ada toma a tierra e De lo contrario podr a e De lo contrario podr a e De lo contrario puede provocar un incendio o provocar un incendio o provocar una descarga descarga el ctrica descarga el ctrica el ctrica o incendio debido a la generaci n de calor an No desmonte ni modifique Tenga cuidado al No use el cable de alimentaci n los productos desembalar e instalar el cerca gas inflamable o aparato materiales combustibles tales como la gasolina benceno disolvente etc e Puede ocasionar fallos y una Los bordes afilados pueden e Podr a ocurrir una explosi n o descarga el ctrica provocar lesiones incendio Manual del usuario 3 Precauciones de seguridad E Operaci n No use
58. the wall sleeve at the rear filange SS SS seers ee SS SS sates eee 3 e eS Ss S SS SS Se see CSS LS PS SES RIIS ns IIS III BROD ls A Place the plastic grille Figure 9 Fasten the 4 washer screws to secure the grille to the wall sleeve If you need plastic nuts to mount plastic grille to the inside of the wall sleeve there are plastic nuts in the installation kit The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges Fasten the screws Figure 10 14 Room Air Conditioner a Remove the backing from the Horizontal Insulation strip 132 x 5 3 x 273 16 and attach that to the inside bottom of the sleeve as shown below Remove the backing from the Around Insulation strip 138 x 374 x 611 2 and attach that to the inside front of the sleeve as shown below Around Insulation Horizontal Insulation Figure 11 B If the depth of your existing wall sleeve is less than or equal to 18 skip to step 6 Otherwise cut the baffles and the support blocks according to length A in the table below Depth D of the existing Length A A wall sleeve inches inches D Support 18 lt D lt 18 3 4 Block 18 5 8 lt D lt 19 Ya 1 3 4 Baffle 19 44 lt D 22 4 Al Figure 12 PROCEDURE B go Remove the backin
59. tilador est conectado en un enchufe correcto 2 Revise el fusible 3 Compruebe que la tensi n no sea demasiado alta o baja Al ajustarse el enfriamiento el aire no parece fr o lo suficiente 1 Revise si los ajustes de la temperatura son correctos 2 Revise si el filtro de aire no est atascado de polvo En el caso de que s cambie el filtro 3 Compruebe que afuera no haya un obst culo del flujo de aire y si entre la parte trasera del ventilador y la pared o la barrera haya espacio libre de por lo menos 1 metro 20 4 Cierre todas las puertas y ventanas y compruebe que no haya una fuente de calor en la habitaci n Ve gotear agua de la parte posterior de la unidad Ve gotear agua de la parte posterior de la unidad El agua puede ser recogida en la bandeja de base en condiciones de mucha humedad o d as de lluvia Esta agua desborda y gotea desde la parte posterior de la unidad Sonidos r Goteo o chapoteo Traqueteo agudo Las gotas de agua que caen sobre el condensador durante la normal operaci n del producto pueden producir sonidos de goteo o chapoteo Los compresores modernos de alto rendimiento pueden presentar un traqueteo agudo durante el ciclo de enfriado Sonido de r fagas de aire Delante de la unidad puede o r el sonido de r fagas de aire que son movidas por el ventilador Borboteo Siseo Un sonido parecido a un borboteo Vibraci n o siseo puede escucharse debido La un
60. tor and used within the United States U S including U S Territories Note Replacement products and repair parts may be new or factory remanufactured and are warranted for the remaining portion of the original unit s warranty period or ninety 90 days whichever is longer Please retain dated receipt or delivery ticket as evidence of the Date of Purchase for proof of warranty you may be required to submit a copy to LG or authorized representative WARRANTY PERIOD 1 year from the Date of Purchase Any internal functional Parts and Labor HOW SERVICE IS HANDLED In Home Service In home service will be provided during the warranty period subject to availability within the United States In home service may not be available in all areas To receive in home service the product must be unobstructed and accessible to service personnel If during in home service repair cannot be completed it may be necessary to remove repair and return the product If in home service is unavailable LG may elect at our option to provide for transportation of our choice to and from a LG authorized service center THIS LIMITED WARRANTY DOES NOT COVER 1 Service trips to deliver pick up or install the product or 8 Cosmetic damage including scratches dents chips or for instruction on product use other damage to the finish of the product unless such 2 Replacing house fuses or resetting of circuit breakers damage results from defects in materials or
61. trol panel not remote control NOTICE This feature is reminder to clean the Air Filter See Maintenance for more efficient operation The LED light will illuminate after 250 hours of operation AUTO RESTART During operation in failure of electric power the unit runs as previous setting operation ENERGY SAVER The unit defaults to Energy Saver mode each time the unit is switched on except restoration after an electrical power outage and fan mode A CAUTION The remote controller will not function properly if strong light strikes the sensor of the air conditioner or if there are obstacles between the remote controller and the air conditioner Inserting the Remote 1 Push out the cover on the back of the remote control with your thumb 2 Pay attention to polarity and insert one new AAA 1 5V battery 3 Reattach the cover Do not ure rechargeable battery Make sure that the battery is new Do not mix alkaline standard Carbon zinc or rechargeable Nickel cadmium battery In order to prevent discharge remove the batteries from the remote control if the air conditioner is not going to be used for an extended period of time Keep the remote control away from extremely hot or humid places To maintain optimal operation of the remote control the remote sensor should not be exposed to direct sunlight Owner s Manual 19 Operating Instructions Ventilation Control Push the lever to the CLOSE position to
62. ue el receptor esta debidamente neutralizado Desconecte el cord n de energ a del adaptador utilizado una mano en cada uno De lo contrario la terminal del adaptador puede romperse NO UTILICE el aparato con un enchufe roto B SITUACIONES EN LAS CUALES EL APARATO ES DESCONECTADO CON FRECUENCIA No utilice un adaptador en estas circunstancias Desconectar el cord n de energ a con frecuencia lo llevar al eventual rompimiento de la terminal de neutralizaci n La saluda de energ a de la pared debe ser reemplazada por una salida de tres patas neutralizada Instalaci n A Instalaci n Extraiga la l mina de embalaje del alojamiento del EQUIPO DE INSTALACI N aparato de aire acondicionado y la esquinera y cinta azul del aparato de aire acondicionado REQUISITOS DE INSTALACI N ntis DLN LEE LO AEE POLL SEI gees oe LOLOL Si utiliza un alojamiento de pared existente debe tomar sus EG LILI 4 medidas LEH 2 opciones de tama o 2 ETA ALU al Instale el nuevo aparato de aire acondicionado segun estas instrucciones de instalaci n para conseguir el mejor rendimiento Todos los alojamientos de pared utilizados para montar el nuevo ia m aparato de aire acondicionado deben tener su estructura en un buenas condiciones y tener una rejilla posterior para fijar con U seguridad el nuevo aparato de aire acondicionado FIG 1 i gt Con la caja protectora LGE puede suministrada opci
63. unit e The air conditioner is not intended for use by young children or invalids without supervision e Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only 2 Room Air Conditioner Safety Precautions E Safety Precautions To prevent injury to the user or other people and property damage the following instructions must be followed E Incorrect operation due to ignoring instruction will cause harm or damage The seriousness is classified by the following indications A 7 WARNING This symbol indicates the possibility of death or serious injury ACAUTION This symbol indicates the possibility of injury or damage to properties only Meanings of symbols used in this manual are as shown below S amp Be sure not to do Be sure to follow the instruction k E Installation A Don t use a power cord a Always plug into a grounded Do not modify or extend the plug or a loose socket outlet power cord length which is damaged e Otherwise it may cause a e Otherwise it may cause a e lt will cause electric shock or fire or electrical shock fire or electrical shock f
64. y shake the excess water from the filter completely Replace the filter How to Attach Front Grille to Cabinet The front grille can be removed for cleaning or to check the model and serial numbers For your safety you should attach the front grille as the following procedures 1 Pull down front grille from the cabinet top 3 Open the inlet grille 2 Push front grille s tips toward the cabinet in 4 Tighten the screw through the front grille into order to insert front grille s tabs into the the plate of control box cabinet 5 Close inlet grille Guide the lever carefully through the grille as you push it in SS Owner s Manual 21 Maintenance and Service Common Problems and Solutions i Before Calling for Service If you have problems with your air conditioner read the following information and try to solve the problem If you cannot find a solution turn off the air conditioner and call 1 800 243 0000 Air conditioner does not operate 1 Ensure that the air conditioner is plugged into an outlet of the proper voltage and amperage 2 Check the fuse or circuit breaker 3 Check whether the voltage is unusually high or low Air does not feel cold enough on the cooling setting 1 Ensure that the temperature settings are correct 2 Check to see if the air filter is clogged with dust If so clean the filter 3 Ensure that the air flow from the outside is not obstructed and that there is a clearance of