Home

Suncourt VS110-CRD Instructions / Assembly

image

Contents

1. WIRING SCHEMATIC MOTOR 120VAC 60Hz TP L N L 120VAC 60Hz MAINTENANCE Inspect the product at least once every 12 months for excessive dust and dirt build up on the impeller more frequently in dusty environments Clean as necessary The unit must be disconnected from power during inspection and or cleaning FIVE YEAR LIMITED WARRANTY Subject to the following limitations Suncourt Inc manufacturer warrants that the Centrax centrifugal fan will for 5 five years from date of original purchase remain free from appearance of defects in workmanship or materials This warranty is subject to the following limitations a manufacturer s liability is limited to the replacement or repair of the unit as decided by the manufacturer b a defective unit must be returned prepaid with proof of purchase to Suncourt and c this warranty does not apply to defects resulting from the alteration abuse accidental damage unauthorized repair or misuse of the unit This warranty is given in lieu of all other warranties guarantees and conditions on manufacturer s part and the manufacturer shall have no tortious or other liability in respect to this Centrax centrifugal fan Actual product appearance may differ from illustrations Suncourt reserves the right to modify any or all of its products features designs components and specifications without notice TOOLS NEEDED www suncourt com SUNCOURT INC
2. P O BOX 40 DURANT IOWA 52747 0040 1 800 999 FANS 3267 Printed In China WNT468 0713 C01
3. VENTILATION USE ONLY DO NOT USE TO EXHAUST FIGURE 1 MOUNTING BRACKETS HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS OR DUST Use supply wires suitable for 105 C WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction d When cutting or drilling into walls or ceilings avoid damaging electrical wiring and other hidden utilities e Ducted fans must always be vented to the outdoors f If this unit is to be installed over a tub or shower it must be marked appropriately for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit g NEVER place a switch where it can be reached from a tub or shower h When used in an attic install exhaust side of the fan facing an unoccupied space i This unit has an unguarded impeller Do not use in locations readily accessible to people o
4. INSTALLATION INSTRUCTIONS FOR CENTRAX CENTRIFUGAL FAN READ AND SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SUNCOURT With the use of any electrical appliance it is important to observe all basic precautions to minimize the risk associated with use such as electrical shock fire or injury to persons If this unit is installed in a bathroom or kitchen power must be supplied from a ground fault circuit interruptor GFCI Read these instructions before using your Centrax fan NEVER EXPOSE YOUR CENTRAX FAN TO TEMPERATURES OVER 140 F 60 C INSTALLATION 1 Install mounting brackets to fan Refer to Figure 1 2 Secure mounting brackets to a fixed structure Refer to Figure 2 3 Connect the Centrax to ventilation system using 6 6 screws supplied when connecting to rigid duct or 2 cable ties supplied when connecting to flex duct 4 Connect to power source Refer to Figure 3 CAUTION Before carrying out any maintenance or servicing ensure the unit is disconnected Model 8 x 1 Self een Machine Hex Nut MOUNTING HARDWARE INCLUDED E 8 x 5 8 Screw Screw 0 Rubber Washer Flat Washer Tow aya aya aya aya aya ay2_ aE 10 x 1 10 x 3 4 10 Lock Rubber Flat Mounting Screw Trnoater2 Qty 8 Qty 8 Qty 8 Qty 8 Qty 8 aye 8 aya 4 Cable Ties For Securing Flex Duct Connection Included in all units from the main supply FOR GENERAL
5. r animals j Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities NOTE Rubber washer must be placed between bracket and housing Mounting Bracket FIGURE 2 MOUNTING FAN INTAKE ELECTRICAL CONNECTIONS 1 Remove the screws from the electrical box cover plate 2 Install the appropriate size strain relief or conduit fitting in knock out provided on the side of the electrical box Run the incoming power through the strain relief or conduit and knockout 3 Connect the incoming power according to the wiring diagram Refer to Figure 3 4 Secure the strain relief and reattach the electrical box cover The fan is now ready for use FIGURE 3 WIRING DIAGRAM Wiring diagram does not apply to units with installed cord PRE WIRED FACTORY CONNECTIONS WHITE NEUTRAL BLACK LINE GREEN OR GREEN YELLOW GREEN YELLOW GROUND GROUND CUSTOMER CONNECTIONS 120VAC 60Hz WHITE NEUTRAL BLACK CAPACITOR amp WIRE NUT BLACK LINE GREEN OR GREEN YELLOW GROUND

Download Pdf Manuals

image

Related Search

Related Contents

User-Manual VSpace-Server-7.0  Samsung ML-3051N 用戶手冊  Einbauanleitung Installation Manual Opel Mocca 1/2012  Télécharger - Fisher Scientific  Chapitre 3    GUÍA DEL USUARIO HMP155 - M210912ES-C  Installation Instructions    Samsung SCX-4720FN Urządzenie  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.