Home
Broan QTRE080 Instructions / Assembly
Contents
1. HOUSING CEILING MATERAL GRILLE COOKING AREA Do not install above or inside this area NOT FOR USE IN A COOKING AREA Cooking Equipment INSULATION Can be placed around and over fan housing 4 IN ROUND ELBOW S Purchase separately The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed Use a roof cap or wall cap that has a built in damper to reduce backdrafts Plan to supply the unit with proper line voltage and appropriate power cable eS A MODELS QTR050F QTREO80 QTRE110 Sa ce Page 3 INSTALL HOUSING amp DUCT 1a Mount housing to joist or I joist Use a pliers to bend housing TABS out to 90 Hold housing in place so that the housing tabs contact the bottom of the joist The housing mounts with four 4 screws or nails Screw or nail housing to joist through lowest holes in each mounting flange then through highest holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole HOLE FOR OPTIONAL BOTTOM EDGE OF FRAMING Extend HANGER BARS to the width of the framing Hold ventilator in place with the hanger bar tabs wrapping around the BOTTOM EDGE OF THE FRAMING NAIL ventilator to framing or fasten with screws not provided through HOLES near nails To ensure a noise free mount
2. at www broan com 99044371A
3. BROAN QTR QTRE SERIES VENTILATORS To register this product visit www broan com MODELS QTR050F QTREO80 QTRE110 Page 1 READ AND SAVE THESE INSTRUCTIONS WARNING A iN TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR IN JURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the ser vice disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equip ment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authori ties 5 When cutting or drilling into wall or ceiling do not damage electrical w
4. Secure hanger bars together of each mounting with SCREWS or use a pliers to crimp mounting channels flange and the tightly around hanger bars I joist OR 1b Mount housing anywhere between 2 Attach damper trusses joists or I joists using hanger duct connector bars Snap damper duct Sliding hanger bars are provided to allow for accurate posi connector onto housing tioning of housing anywhere between framing They can be Make sure connector is used on all types of framing I joist standard joist and truss flush with top of housing construction and span up to 24 and damper flap falls closed 3 Install 4 inch round ductwork Connect 4 inch round ductwork to damper duct connector Run ductwork 2 gic to a roof cap or wall CHANNEL 2 cap Tape all ductwork connections to make them secure and air tight Attach the MOUNTING CHANNELS to the housing using the SCREWS supplied Make sure TABS face up as shown Use the set of channel mounting holes marked STD to mount the housing flush with the bottom of the drywall Use the other set of holes not marked to mount the housing flush with the top of the drywall BROAN CONNECT WIRING ON OFF SWITCH I I I I I I I BLKI GRD SWITCH BOX RECEPTACLE ON OFF SWITCH purchase separately SWITCH BOX G e J oD WIRING PLATE 120 VAC LINE IN 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use pro
5. iring and other hidden utilities Ducted fans must always be vented to the outdoors 7 Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit ceiling installation only 8 This unit must be grounded O CAUTION A 1 For general ventilating use only Do not use to exhaust hazard ous or explosive materials and vapors 2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point up DO NOT MOUNT THIS PRODUCT IN A WALL 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Please read specification label on product for further informa tion and requirements CLEANING amp MAINTENANCE For quiet and efficient operation long life and attractive appear ance lower or remove grille and vacuum interior of unit with the dusting brush attachment The motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the blower assembly includes motor and impeller OPERATION Use an on off switch or speed control to operate this ventilator See Connect Wiring for details Use of speed controls other than the Broan Models 78V and 78W may cause a motor humming noise WARRANTY BROAN THREE YEAR LIMITED WARRANTY Broan warrants to the original consume
6. ove limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan at the address or telephone number stated below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC Hartford Wisconsin www broan com 800 558 1711 Installer Leave this manual with the homeowner BROAN TYPICAL INSTALLATIONS Housing mounted to I joists Housing mounted anywhere between I joists using hanger bars Housing mounted to joists Housing mounted anywhere between joists using hanger bars Housing mounted anywhere between trusses using hanger bars I JOIST SPACER BLOCK MOUNTING TABS TN CEILING MATERIAL GRILLE JOIST POWER CABLE HANGER BARS span up to 24 CEILING MATERAL GRILLE CEILING GRILLE MATERIAL HANGER BARS span up to 24 HOUSING CEILING CEILING JOIST MATERAL GRILLE HANGER BARS span up to 24 HOUSING CEILING MATERAL GRILLE MODELS QTR050F QTREO80 QTRE110 Page 2 Housing mounted one ANGER DARS anywhere span up to 24 between trusses using hanger bars
7. per UL approved connector to secure house wiring to wiring plate Connect wires as shown in wiring diagrams SERVICE PARTS Panno Description 97016466 Housing 97016449 Duct Connector 4 98010102 Wiring Plate 99170245 Screw 8 18 X 375 97018010 Wire Panel Harness Assembly 97017782 Blower Assembly QTR050F 97017853 Blower Assembly QTRE080 97017854 Blower Assembly QTRE110 97016497 Grille Assembly includes key no 8 99140199 Grille Spring 2 req d 97018014 Spacer 2 supplied QTHB1 Hanger Bars QTREO80 QTRE110 99420665 Thumbscrew 8 18 x 375 Order service parts by Part No not by Key No SERVICE NOTE To remove Blower Assembly Unplug motor Remove thumbscrew 11 from motor plate flange Find the single TAB on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housing Or insert a straight blade screwdriver into slot in housing next to tab and twist screwdriver MODELS QTR050F QTRE080 QTRE110 Page 4 INSTALL GRILLE 5 Finish ceiling Install ceiling material Cut out around housing 6 Attach grille to housing Squeeze grille springs and insert them into slots on each side of housing 7 Push grille against ceiling Replacement parts can be ordered on our website Please visit us
8. r purchaser of its products that such products will be free from defects in materials or workmanship for a period of three years from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this three year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal main tenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan faulty installation or installation contrary to recommended installation instructions The duration of an implied warranty is limited to the three year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN S OBLIGATION TO REPAIR OR REPLACE AT BROAN S OP TION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN SHALL NOT BE LIABLE FOR INCI DENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the ab