Home
        SPT AC-2221 Use and Care Manual
         Contents
1.  before being installed to the unit     SPECIFICATION    e Model Number  AC 2221   e Adapter Power Input  100 240V AC  50 60Hz  e Unit Power Input  24V  2 09A   e Power Consumption  50w   e Motor type  DC brushless motor   e Dimensions  21 3 x 16 x 7 inches   e Weight  14 lbs    IMPORTANT SAFETY INSTRUCTIONS    Please read all instructions before using this product  Save these instructions for easy  reference  When using electrical appliances basic precautions should always be  followed to reduce breakage  risk of fire  electric shock and injury to persons including  the following       Read all instructions before operating the air cleaner    e Place the air cleaner where it is not easily knocked over by persons in the household   e ALWAYS unplug air cleaner when not in use      DO NOT use any product with a damaged cord or plug  or if product malfunctions  is  dropped or damaged in any manner      Keep the power cord away from heated surfaces      DO NOT use air cleaner outdoors    e NEVER use the air cleaner unless it is fully assembled      DO NOT run power cord under carpets and DO NOT cover with throw rugs  Arrange  cord so it will not be tripped over      DO NOT use air cleaner where combustible gases or vapors are present      DO NOT expose the air cleaner to rain  or use near water  in a bathroom  laundry area  or other damp locations    e To disconnect air cleaner  first press Power Button to turn air cleaner OFF and remove  plug from outlet      DO NOT allow foreig
2. REPLACING FILTERS    m Lock    Excellent  Good  Moderate  Poor    Filter Speed Timer Air Quality Very Poor    The life bars on the LCD display indicate the life span of the filters  The life bars reduce  gradually through the use of the air cleaner until one or both filters reach the suggested life  span  The life bars will then flash to remind filter replacement    The suggested life span for the Carbon pre filter is 1400 hours  The suggested life span  for both the HEPA and VOC removing filter is 2800 hours     Steps to replace the filters      Turn off the air cleaner by pressing the power button  Then unplug the unit from the  electrical outlet      Firmly press the release buttons on both sides of the front grill and pull the grill outward t  o remove      Replace the old filter  Anti bacterial HEPA   Activated carbon pre filter   VOC filter  with a  new one  Note  Arrows face in  toward  the machine and pull tabs face out  toward you   when replacing filters      Reposition the front grill      Turn the unit back on      Press and hold the filter reset button until the filter life bar resets with a beep sound  The  reminder is reset        To prevent mis operation  the filter reset button is a very small object next to the LCD  display and requires depressing by a pen point or other similar slender items     Note    e Make sure to turn off power and unplug the unit before replacing the filters   e None of the filters are washable    e All filter polybags must be removed
3. action  When dimmed  press any key but Sleep button will bring  unit back to full brightness           Control Lock button  Press and hold this button for about 3 seconds to lock the  control panel  Unit will not respond to any touch control until the control lock is  removed by pressing and holding the button for another 3 seconds  This is to  prevent children or pets making accidental changes               3    
4. ctivated carbon pre filter    Front cove Rear housing                      Front cover release button          Power supply    Power cord    AIR CLEANER  WITH DUAL DC MOTOR    Model  AC 2221    Thank you for your purchase of this new SUNPENTOWN product  Please read thor   oughly and retain this manual for future references    CAUTION    1  This appliance is intended for household only    2  Never operate this unit if the cord is damaged  In case of damage  the cord must  be replaced by the manufacturer  an authorized service agency or a similarly quali   fied electrician    3  Close supervision is necessary when this item is used by or near children    4  The appliance is not intended for use by persons  including children  with reduced  physical  sensory or mental capabilities  or lack of experience and knowledge   unless they have been given supervision or instruction concerning use of appliance  by a person responsible for their safety     OPERATION    Important  Before using the air cleaner for the first time  you need to remove the polybags  of the filters  Please refer to    Steps to replace the filters    on the next page   Connect the plug to a 120V power outlet and the air cleaner will be on    stand by    status        0000000                                                             Filter reset button    Power ON OFF button  Press and hold the button for about a second to turn  on off the air cleaner  Once the unit is on  the built in air quality sensor will sta
5. n objects to enter ventilation or exhaust opening  as this may  cause electric shock or damage to the air cleaner      Place air cleaner near a power outlet and avoid using an extension cord    e DO NOT block air outlets or intakes    e The air cleaner has a polarized plug  one blade is wider than the other   To reduce the  risk of shock  this plug is intended to fit in a polarized outlet only one way  If the plug  does not fit fully in the outlet  reverse the plug  If it still does not fit  contact qualified  personnel to install the proper outlet  DO NOT try to alter the plug in any way     A loose fit between the plug and the AC outlet  receptacle  may cause overheating  and distortion of the plug  Contact a qualified electrician to replace loose or worn  receptacles      DO NOT sit  stand on  or place heavy objects on the air cleaner    e ALWAYS disconnect power supply before servicing     WARNING  To reduce the risk of fire or electric shock  DO NOT use this product with  any solid state speed control device     REPLACEMENT FILTER KIT    Model Number  2221 Filter  The Replacement Filter Kit contains  Activated carbon pre filter x 2  Anti bacterial  HEPA filter x 1  VOC filter x 1    YOUR GUARANTEE    If this product is found to be faulty as a result of faulty materials or workmanship within one  year from date of purchase  it will be repaired free of charge     This guarantee is subject to the following terms    Sunpentown must be notified of the fault    Proof of purcha
6. rt  detecting the room air quality  While detecting  the leaf on the LCD display will keep  flashing  This takes 3 5 minutes to complete     Timer setting button  When the air cleaner is running  press the button to set the     off timer  The timer can be set from one to nine hours  The LCD display will  illuminate set time  When the set time is up  the air cleaner will turn off automati   cally     Speed control button      Press this button to increase fan speed  The highest fan  speed is 5     Speed control button      Press this button to decrease fan speed  The lowest fan  speed is 1    Auto mode control button  When the    Auto    mode is selected  the air cleaner will  adjust the fan speeds automatically based on the air quality detected  For example   if the detected air quality is    Excellent     the unit will run at the lowest speed to save  energy  If the air quality is    Very Poor     the unit will run at the highest speed to  expedite the air cleaning process     06060          Sleep mode control button  When the    Sleep    mode is selected  the air cleaner  will reduce fan speed down to 1  lowest  and both the brightness of the control  buttons and LCD display will dim by 70   Pressing the sleep  button again or adjusting fan speed under sleep mode will exit sleep mode        For energy saving concern and to prolong the product   s life span  asides from  the    Sleep    mode  the control buttons and LCD display will both dim by 70  after  15 seconds of last 
7. se must be presented to Sunpentown   s nominated representative    The warranty will be void if the product if modified  misused or repaired by an unauthorized  person    The warranty after repair will not be extended beyond the original one year period    All replacement parts will be new or reconditioned    Parts  which are replaced  become the property of Sunpentown    The warranty applies for the use of the product in the USA only     What is NOT COVERED    Warranty does not include freight charges    Damage due to installation error  product abuse and or misuse    Incidental or consequential damage caused by possible defects with this product   Labor cost incurred for the installation and or removal of a possible defective unit   Damage to product caused by improper power supply voltage  accident  fire  floods or acts  of nature    Failure of product resulting from unauthorized modifications to the product   Improper installation or failure to perform the necessary maintenance    Normal wear and tear on parts or replacement of parts designed to be replaced   Damage to personal property from use of product    Replacement or repair of household fuses  circuit breakers  wiring or plumbing     This GUARANTEE is in addition to your Statutory Rights    SUNPENTOWN INTERNATIONAL INC   14625 Clark Ave  City of Industry  CA 91745  Tel  800 330 0388  service sunpentown com  www sunpentown com    PART LIST    Control panel    VOC filter    Anti bacterial HEPA filter  Air outlet    A
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Dino-Lite Handheld Digital Microscope AM413T User`s Manual  Avaya 555-250-701 IP Phone User Manual  MF25 User Manual  Zanussi ZWF 1222 User's Manual  User Manual  第27回鹿嶋市花火大会  Connected Ohio Records for Educators (CORE)  仕様書 PDFファイル  Réglements techniques GAC Zone Ouest 2015-2016    Copyright © All rights reserved. 