Delta Breez SLM70 Instructions / Assembly
Contents
1. notice OPERATION 1 Single Speed Model VFB050B3A1 Single speed control mode Turn on the power switch to operate ON or OFF and LED indicator is green 2 Single Speed Model VFBO70B3A1 Single speed control mode Turn on the power switch to operate ON or OFF and LED indicator is green 3 Dual Speed Model VFB070B3X1 3 1 Low speed control mode Cycling ON OFF switch to operate low speed mode and LED indicator is green 3 2 High speed control mode Cycling ON OFF switch to operate high speed mode and LED indicator is amber MAINTENANCE WARNING Disconnect power source before working on unit Routine maintenance must be done every year CAUTION 1 Never use gasoline benzene thinner or any other such chemicals for cleaning the ventilating fan 2 Do not allow water to enter motor 3 Do not soak resin parts in water over 60 C CLEANING i Pull down the spring to remove grille 2 Wash and clean grille Use non abrasive kitchen detergent wipe dry with new cloth 3 Remove dust and dirt from ventilating fan using a vacuum cleaner 4 Using a cloth dampened with kitchen detergent remove any dirt from ventilating fan Wipe dry with new cloth 5i Replace grille INSTALLATIONS Install with wood frame Model No VFBO50B3A1 VFBO70B3A1 VFBO70B3X1 Install Dim Inch 10 A NELTA 7 5X7 25 7 5X7 25 7 5X7 25 Remove motor plate from housing by removing three screws
2. A NELTA INSTALLATION AND OPERATING INSTRUCTIONS CEILING WALL VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION 1 Make sure that the electric service supply voltage is AC 120V 60Hz 2 Follow all local electrical and safety codes as well as the Nation Electrical Code NEC and the Occupation Safety and Healthy Act OSHA 3 Always disconnect the power source before working on or near the ventilating fan motor or junction box 4 Protect the power cord from sharp edges oil grease hot surfaces chemicals or other objects 5 Do not kink the power cord 6 Do not install the unit where ducts are configured as shown in Fig A 7 Provide suction parts with proper ventilation 8 This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit 9 These ventilating fans are intended for residential usage only WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and
3. Fig C Remove wiring cover from housing by pulling straight out Choose a hole and use a slotted screwdriver to remove it Fig D Follow all local electrical and safety codes NEVER place a switch where it can be reached from a tub or shower Connect wires as shown in wiring diagrams Fig E Using wire nuts connect house power cable to ventilating fan wires 14 AWG 2 1 mm is the smallest conductor that shall be used for branch circuit wiring Fig F Fig E Insert the duct into the duct connector and tape all ductworks connection to make them secure and air tight Install the duct with a gradient 1 2 to the outside Fig G Ventilation Fan Black Switch Box Loo New installation prior to finishing the ceiling or wall White On Purchase separately Live Receptacle Plug connector WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc Delta Electronics warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase Limitations and Exclusions During the warranty period a replacement for any defective product will be supplied free of charge for installation by the consumer The warranty provided herein does not cover charges for labor or other costs incur
4. electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Do not install this ventilating fan where air temperature may exceed 40 C 104 F Ducted ventilating fan must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit These models are UL listed for tub and shower enclosures Do not use this unit with any other solid state control device Solid state controls may cause harmonic distortion which can cause motor humming noise Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked secu
5. K LANNASASSASSANLANALLNS NS SS
6. products use or performance regardless of the form of action whether in contract tort including negligence strict product iability or otherwise This warranty does not extend to fluorescent lamp starters and tubes WIRE NUT 5 The warranty does not cover if user does not comply with manufacture s installation manual To qualify for warranty service you must notify Delta Electronics at the address or telephone number below Delta Electronics shall have no liability to the original owner user with respect to any defect caused by abuse misuse neglect improper transportation or storage improper testing improper installation improper operation improper use improper maintenance improper repair improper alteration improper modification tampering or accident of products or parts thereof or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products specifications using three screws Fig C Squeeze grille springs together and insert springs into slots in motor plate Push grille up against ceiling or wall When the power on check for abnormal vibration or sound Insert the mounting Address 4405 Cushing Parkway Fremont CA 94538 US Toll Free Number 1 888 979 9889 springs into the slots and mount the grille to the body Fig
7. red in the troubleshooting repair removal and installation service All returns of defective parts or products must include the product model number and must be made through an authorized Delta Electronics distributor Authorized returns must be shipped prepaid Repaired or Neutral replacement products will be shipped by Delta Electronics F O B shipping Insert the fan between joists Make sure the fan body is level and perpendicular with the joist Fig point Delta Electronics shall not be liable for any indirect incidental Green H Replacement installation After making electrical and ductwork connections see steps 2 5 nail housing in place Drive nails through the housing where indicated by arrows Fig I New installation in an existing ceiling or wall Bend tabs outward 90 Use a screw driver if desired and position housing so that tabs rest against bottom edge of joists or front of stud Nail housing to joist or stud using four nails to ensure a solid quiet installation Ceiling installations Tabs on opposite side of housing can be bent outward to rest on top of 1 2 ceiling material and provide extra stability Fig J Plug in motor and locking the fan body back by Ground consequential punitive or special damages arising out of or in connection with
8. rely fasten a prominent warning device such as a tag to the service panel 12 NEVER place a switch where it can be reached from a tub or shower 13 Not to be installed in a ceiling thermally insulated to a value greater than R40 This is required for installation in Canada only Turning angle too large Duct shrink A J N n __ _ S o NY Too many elbows Elbow near the body Body N V msan a e Note Design and specifications subject to change without Fig A CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 Not for use in cooking area Fig B 3 This product must be properly grounded Cooking area _ _ D DI eo o or m a i xn o7 o H r NS J e I loor Fig B SUPPLIED ACCESSORIES DIMENSIONS a D A Model No Voltage Frequency Power Air Flaw Weight Hz w