Delta Breez VFB050C4L1 Instructions / Assembly

image

Contents

1. 2 1 Insert the duct into the duct connector and tape all ductworks connection to make them secure and air tight 2 2 Install the duct with a gradient 1 2 to the outside X N Inside Outside Y Tape Body Duct 1 i Ceiling Grille Gradient 1 2 A NELTA 3 CONNECT WIRING 3 1 Follow all local electrical and safety codes 3 2 NEVER place a switch where it can be reached from a tub or shower 3 3 Connect wires as shown in wiring diagrams LIGHT BLU LIGHT WHT SWITCH bd BLUE ae FAN SWITCH blk ins WHT BLK BLK LINE WHT IN g GRD HOUSE ELECTRICAL BOX LIGHT FAN ELECTRICAL BOX 3 4 Using wire nuts not provided connect house power cable to ventilating fan 3 5 14 AWG 2 1 mm is the smallest conductor that shall be used for branch circuit wiring 4 TEST RUN amp GRILLE ATTACHMENT 4 1 When the power on check for abnormal vibration or sound 4 2 Insert the grille bracket into the main body and lock screw M4x6 to fix on the main body i iy P Screw M4 x 6 4 3 Mount the grille to the grille bracket by lock screw 8 3230 _ Lock screw 8 32 x 30 Lock lens cover 5 OPERATION 5 1 Single Speed Model VFBO80C4L1 Turn on the power switch to operate ON or OFF and LED indicator is green Turn on the power to operate main light on off 5 2 Si
2. storage improper testing improper installation improper operation improper use improper maintenance improper repair improper alteration improper modification tampering or accident of products or parts thereof or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products specifications DIMENSIONS _ 4 DUCT Address 4405 Cushing Parkway Fremont CA 94538 US Toll Free Number 1 888 979 9889
3. A NELTA INSTALLATION AND OPERATING INSTRUCTIONS CEILING VENTILATION FAN LIGHT READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION 1 Make sure that the electric service supply voltage is AC 120V 60Hz 2 Follow all local electrical and safety codes as well as the Nation Electrical Code NEC and the Occupation Safety and Healthy Act OSHA 3 Always disconnect the power source before working on or near the ventilating fan motor or junction box 4 Protect the power cord from sharp edges oil grease hot surfaces chemicals or other objects 5 Do not kink the power cord 6 Do not install the unit where ducts are configured as shown in Fig A Z Provide suction parts with proper ventilation 8 This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit 9 These ventilating fans are intended for residential usage only WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work an
4. d electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted ventilating fan must always be vented to the outdoors Z Do not install this ventilating fan where air temperature may exceed 40 C 104 F 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 9 Do not use this unit with any other solid state control device Solid state controls may cause harmonic distortion which can cause motor humming noise 10 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning de
5. g fan Wipe dry with new cloth 4 Replace grille p g Limitations and Exclusions 1 During the warranty period a replacement for any defective product will be supplied free of charge for installation by the consumer The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting repair removal and installation service 2 All returns of defective parts or products must include the product model number and must be made through an authorized Delta Electronics distributor Authorized returns must be shipped prepaid Repaired or replacement products will be shipped by Delta Electronics F O B shipping point 3 Delta Electronics shall not be liable for any indirect incidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict product liability or otherwise 4 This warranty does not extend to fluorescent lamp starters and tubes 5 The warranty does not cover if user does not comply with manufacture s installation manual 6 To qualify for warranty service you must notify Delta Electronics at the address or telephone number below 7 Delta Electronics shall have no liability to the original Owner user with respect to any defect caused by abuse misuse neglect improper transportation or
6. ngle Speed Model VFBO50C4L1 Turn on the power switch to operate ON or OFF and LED indicator is green Turn on the power to operate main light on off MODELS VFBO80C4L1 VFBO50C4L1 6 MAINTENANCE WARNING SPECIFICATIONS Voltag Frequenc Dei Air Flow T Disconnect power source before working on unit Routine Model No y W 0 1SP o Note maintenance must be done every year V Hz CFM CAUTION VFBO80C4L1 120 60 35 80 64 Light 1 Never use gasoline benzene thinner or any other VFBOSOC4L1 120 60 3i 50 64 Light such chemicals for cleaning the ventilating fan Note Design and specifications subject to change without 2 Do not allow water to enter motor HOCE 3 Do not soak resin parts in water over 60 C eA WARRANTY 1 Open lens cover Remove the light bulbs carefully Disassemble the lock screw 8 32x30 and light power connections to remove grille DELTA ELECTRONICS THREE YEAR LIMITED 2 Wash and clean grille CAUTION Do not let water WARRANTY into the lamp base Use non abrasive kitchen detergent wipe dry with a new cloth Delta Electronics Inc Delta Electronics warrants to the Original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship This warranty is limited to three 3 years from the original date of purchase 3 Using a cloth dampened with use non abrasive kitchen detergent remove dust and dirt from ventilatin
7. vice such as a tag to the service panel 11 NEVER place a switch where it can be reached from a tub or shower 12 Not to be installed in a ceiling thermally insulated to a value greater than R40 This is required for installation in Canada only Turning angle too large Duct shrink oS Too many elbows Elbow near the body Body gt o Fig A CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 Not for use in cooking area Fig B 3 This product must properly connect to the grounding conductor of the supply circuit Cooking area A Do not install above or inside this area SS NSE oes eae ae w AN a Cooking Equipment _ floor 7 Fig B SUPPLIED ACCESSORIES Duct 4 As breez GreenBuilder MODELS VFBO80C4L1 VFBO50C4L1 GU24 base bulb lamp Grille bracket 26W Long Screw 44x25 Screw M4x6 Screw 8 32x30 1 INSTALLATIONS MOUNT HOUSING WITH FLANGE 1 2 To bend the housing tabs out to 90 degree and make housing tabs contact the bottom of the joist mt p Li lt A a i The housing mounts with 4 screws w4x25 Screw housing to joist through lowest holes in each mounting flange then through the other holes re lonr pi SCREW 2 DUCT CONNECTION