Home
        Air King AK80H Instructions / Assembly
         Contents
1.                             Installer  Installation Date           Place of Purchase  Model Number           5084461 New 3 12 WWW  AIRKINGLIMITED COM 4of8    INSTRUCTIONS IMPORTANTES    MODE D EMPLOI    Mod  le   AK80H    Ventilation Products    Ventilateur d   Evacuation       LIRE ET CONSERVER CES INSTRUCTIONS    LIRE SOIGNEUSEMENT AVANT DE TENTER D   ASSEMBLER  INSTALLER  OPERER OU DE R  PARER LE PRODUIT DECRIT   PROT  GEZ  VOUS M  ME ET LES AUTRES EN OBSERVANT TOUTE L INFORMATION DE S  CURIT    FAILLIR A SE CONFORMER AUX  INSTRUCTIONS PEUT R  SULTER EN BLESSURE PERSONNELLE GRAVE ET OU EN DOMMAGE    LA PROPRI  T       CONSERVER CES INSTRUCTIONS POUR R  F  RENCES FUTURES   INSTRUCTIONS G  N  RALES DE S  CURIT      Lors de l   utilisation d appareils   lectriques  des pr  cautions de base doivent  toujours   tre suivies pour r  duire les risques d incendie  de choc   lectrique et de  blessures corporelles  incluant ce qui suit     AVERTISSEMENT   POUR R  DUIRE LES RISQUES  D   INCENDIE  DE CHOC ELECTRIQUE OU DE BLESSURES  PERSONNELLES OBSERVER CE QUI SUIT      a  Utiliser cette unit   seulement de la mani  re pour laquelle  le fabricant l   a con  u  Si vous aviez des questions  veuillez  contacter le fabricant     b  Avant d effectuer un service ou de nettoyer l   unit    couper  l alimentation   lectrique dans le panneau de distribution  et verrouiller le dispositif de d  connexion afin d   viter que  l alimentation ne revienne accidentellement  Lorsque le dispositif  ne p
2.    Model  AK80H    IMPORTANT INSTRUCTIONS      OPERATING MANUAL    Ventilation Products          READ AND SAVE THESE INSTRUCTIONS    READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE  INSTALL  OPERATE OR MAINTAIN THE PRODUCT DESCRIBED     PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION  FAILURE TO COMPLY WITH  INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE     RETAIN INSTRUCTIONS FOR FUTURE REFERENCE   GENERAL SAFETY INFORMATION    When using electrical appliances  basic precautions  should always be followed to reduce the risk of fire   electric shock and injury to person  including the following     TO REDUCE THE RISK OF FIRE  ELECTRIC SHOCK AND INJURY TO  PERSON  OBSERVE THE FOLLOWING     a     b     Use this unit only in the manner intended by the manufacturer lf  you have questions  contact the manufacturer     Before servicing or cleaning the unit  switch power off at service  panel and lock the service disconnecting means to prevent  power from being switched on accidentally  When the service  disconnecting means cannot be locked  securely fasten a  prominent warning device  such as a tag  to the service panel     TO REDUCE THE RISK OF FIRE  ELECTRIC SHOCK AND INJURY TO  PERSON  OBSERVE THE FOLLOWING     a     5084461 New 3 12    Installation work and electrical wiring must be done by qualified  person s  in accordance with all applicable codes and standards   including fire related construction     Sufficient air is needed for proper co
3.   1  Fan does not operate when the switch is on     2  Fan is operating  but air moves slower than normal     Obstruction in the exhaust ducting     Suggested Remedy    A fuse may be blown or a circuit tripped    Replace fuse or reset circuit breaker   Connector plug from motor is not plugged in    Turn off power to unit  Remove Grill and plug motor into receptacle    in housing  Restore power to unit     Wiring is not connected properly    Turn off power to unit  Check that all wires are connected   Motor has stopped operating     Replace motor     Check for any obstructions in the ducting  The most common are bird  nests in the roof cap or wall cap where the fan exhausts to the outside        3  Fan is operating louder than normal Motor is loose        5084461 New 3 12    Fan blade is hitting housing of unit        Turn off power to unit  Remove grill and check that all screws are fully  tightened  Restore power to unit     Call your dealer for service                    WWW AIRKINGLIMITED COM 3 of 8    LIMITED WARRANTY    WHAT THIS WARRANTY COVERS  This product is warranted against defects in workmanship and or materials    HOW LONG THIS WARRANTY LASTS  This warranty extends only to the original purchaser of the product and lasts for five  5  years from the date of original purchase  or until the original purchaser of the product sells or transfers the product  whichever first occurs    WHAT AIR KING WILL DO  During the warranty period  Air King will  at its sole option  r
4.   vous r  f  rer    la Section 6 Compl  tion de l installation     2  Nettoyage de l assemblage du ventilateur   Nettoyer toutes les parties    l   aide d   un chiffon  sec ou passer d  licatement l   aspirateur sur le ventilateur  NE JAMAIS IMMERGER LES PARTIES  ELECTRIQUES DANS L EAU     Remplacer le fusible ou r  initialiser le disjoncteur     Couper l alimentation    l unit    Retirer la grille et brancher le moteur dans  le r  ceptacle dans le cabinet  Remettre l alimentation sur l unit       Couper l alimentation de l unit    V  rifier que tous les fils sont raccord  s   Remplacez la moteur       2  Le ventilateur fonctionne  mais l air circule  plus lentement que la normale     2  Obstruction dans les conduits d   vacuation     V  rifier pour toute obstruction dans les conduits  Les plus courantes sont  des nids d oiseau dans le chapeau de toit ou mural l   o   le ventilateur  s   vacue vers l ext  rieur        3a  Le moteur est l  che     3  Le ventilateur fonctionne de mani  re plus  bruyante que la normale        5084461 New 3 12    3b  L h  lice du ventilateur frotte contre le cabinet de l unit       Couper l alimentation    l unit    Retirer la grille et v  rifier que toutes les  vis sont compl  tement serr  es  Remettre l alimentation sur l unit       Appeler votre marchand pour un service           WWW AIRKINGLIMITED COM 7 0f8    GARANTIE LIMIT  E    QUE COUVRE CETTE GARANTIE   Ce produit est garanti contre tout vice de fabrication ou de mati  re    COMBIEN DE T
5.  OFF AT SERVICE PANEL BEFORE  STARTING INSTALLATION     SECTION 1    Preparing the Exhaust Fan    1  Unpack fan from the carton and confirm that all pieces are present  In addition to the  exhaust fan you should have   1   Grill  1   Damper Assembly  attached   4   Mounting Rails  1   Instruction Safety Sheet    2  Choose the location for your fan  To ensure the best  air and sound performance  it is recommended that  the length of ducting and the number of elbows be  kept to a minimum  and that insulated hard ducting  be used  Larger duct sizes will reduce noise and  airflow restrictions  This fan will require at least 8   of clearance in the ceiling or wall  and will mount  through drywall up to 3 4  thick  The fan mounts  between 16    or 24    on center joists using the 4 S  provided mounting rails     3  Select the most convenient electrical knockout and  remove using a straight blade screw driver  Figure 1      SECTION 2    New Construction    Figure 1    1  Install the side rails on the housing and position the housing next to the joist  Line up housing  so that it will be flush with the finished ceiling  Secure the ends of the rails with screws or  nails  not included  to the joists and slide the housing into the final position  Figure 2                           Mounting Rails    Figure 2    SECTION 3    Existing Construction    1  Set housing in position between the joist and trace an outline onto the ceiling material   Figure 3   Set housing aside and cut opening  
6.  PAS DISPONIBLES  POUR DES RAISONS  DE S  RET    BEAUCOUP DE COMPOSANTS   LECTRONIQUES ET LA PLUPART DES COMPOSANTS DES CHAUFFAGES NE SONT PAS    LA DISPOSITION DES  CONSOMMATEURS POUR L INSTALLATION OU LE REMPLACEMENT                      de pi  ce  Description de remplacement  Cabinet du ventilateur 5S1202001  Traverses de Montage 581299002  Collet 581299003  Clapet 581299004  Assembl  e de la Soufflante 582202001  Roue de la Soufflante 582202003  Compartiment de Cablage 581202004  Vis  6 par 3 8 po 581999010  Vis  8 par 5 8 po 581999011  Grille 581202005  Ressorts de la grille 581202006  Vis  10 32 par 3 8 po de mise a la terre 581999002  Fil de mise a la terre de calibre   14 581999003  Vis  6 par 3 8 po 581999010  Couvercle de Cable Externe 581202007  Bouton 581299802  Harnais du Capuchon du Moteur 589202502    im      ms                                                                mi hea i a a a a a i aa a a a                   Installateur   Date d installation            Endroit de l achat   Num  ro de mod  le            5084461 New 3 12 WWW AIRKINGLIMITED COM 8of8    
7.  to see the humidity sensor set point  In cases where the  ambient humidity level of the room rises higher than the preset level  the fan will turn on even  if the room is not occupied  This helps prevent conditions that lead to mold growth     CAUTION  MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE  SERVICING THE UNIT     1  To set the desired humidity level of the room  remove the grill and locate the  dehumidistat dial located on the wire compartment cover     2  Set the dial to the relative humidity you want the fan to maintain usually between 50  amp   80   Moist climates will require higher settings than dry climates  When the humidity  level of the room is below this setting the fan will remain off  When the humidity level  rises about this setting the fan will turn on and run until the humidity level falls below  this setting     3 Reinstall the grill and restore power     SECTION 8    Use and Care    CAUTIONS make SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE  SERVICING THE UNIT     1  Cleaning the Grill  Remove grill and use a mild detergent  such as dishwashing liquid   and dry with a soft cloth  NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS   Completely dry grill before reinstalling  Refer to instructions in Section 5 Finishing the  Installation  to reinstall grill     2  Cleaning the Fan Assembly  Wipe all parts with a dry cloth or gently vacuum the fan   NEVER IMMERSE ELECTRICAL PARTS IN WATER     Troubleshooting Guide    Trouble Probable Cause  
8.  un endroit fiable  Figure 5          Couvercle du  Compartiment  de C  blage    b  Compartiment de C  blage Int  rieur  Enlever le vis retenant en place l   ensemble venturi du  ventilateur et soulever pour sortir l assemblage hors du ch  ssis  Figure 6   Enlever la vis du  couvercle du compartiment    c  blage et mettre ce couvercle dans un endroit fiable  Figure 7                                Venturi             Figure 6             Bouton de point  de consigne  d humidit      Couvercle du  Compartiment de  C  blage       WWW AIRKINGLIMITED COM 6 of 8    REMARQUE   Si le raccord du moteur de ventilateur est raccord   au r  ceptacle du ch  ssis  le  d  brancher afin que l   ensemble venturi du ventilateur soit compl  tement enlev       2  Pour un bon fonctionnement  le ventilateur de d  tection d humidit   exigera un  interrupteur    3 voies  non inclus   Faites passer le c  blage entre le ventilateur et  l emplacement du commutateur  Assurez vous de laisser suffisamment de c  blage dans  chaque bo  te pour faire les connexions     la bo  te de commutation  connectez le fil noir  de la maison    la borne commune du commutateur  Connectez le fil noir du ventilateur     l   une des bornes commut  es sur le commutateur  Cette position activera le mode  automatique et le ventilateur s   activera apr  s une   l  vation d humidit    Connectez le  fil rouge du ventilateur    l   autre borne commut  e sur le commutateur  Cette position  activera le mode manuel et activera le vent
9. EMPS CETTE GARANTIE DURE   Cette garantie se rapporte seulement    l acheteur original du produit et dure pendant cinq  5  ann  es de la date de  l achat original ou jusqu      ce que l   acheteur original du produit vend ou transf  re le produit  celui qui se produit en premier    QUE FERA AIR KING   Au cours de la p  riode de garantie  Air King     son choix  r  parera ou remplacera n importe quelle partie ou pi  ces qui s av  rent d  fectueuses ou  remplacera le produit entier par le m  me mod  le ou un mod  le comparable    CE QUE CETTE GARANTIE NE COUVRE PAS   Cette garantie ne s applique pas si le produit   tait endommag   ou arr  te de fonctionner en raison d   un accident  d une  mauvaise manipulation ou op  ration  de dommages d exp  dition  d abus  de mauvaise utilisation  de r  paration faite ou tent  es non autoris  es  Cette garantie ne couvre   pas les co  ts d exp  dition pour le retour des produits    Air King pour la r  paration ou le remplacement  Air King payera les frais d exp  dition de retour de Air King apr  s les  r  parations ou le remplacement de garantie    TOUTES LES GARANTIES  EXPRESSES OU TACITES  COMPRENANT  SANS LIMITATION  TOUTE GARANTIE TACITE DE VALEUR MARCHANDE   DURENT UN AN DE LA  DATE DE L ACHAT ORIGINAL OU JUSQU      CE QUE L ACHETEUR ORIGINAL DU PRODUIT VEND OU TRANSFERE LE PRODUIT  CELUI QUI SE PRODUIT EN PREMIER ET  DANS AUCUN CAS AIR KING N ASSUME AUCUNE RESPONSABILIT   EXPRESSE OU TACITE POUR  I  DES DOMMAGES ACCIDENTELS OU INDIREC
10. TS DE N IMPORTE  QUELLE CAUSE  OU  II  LE REPLACEMENT OU LA R  PARATION DE TOUS FUSIBLES  DISJONCTEURS OU RECEPTACLES DE MAISON  MALGR   N IMPORTE QUOI     LEFFET CONTRAIRE  DANS AUCUN CAS LA RESPONSABILITE D   AIR KING  SOUS UNE GARANTIE EXPRESSE OU TACITE  NE DEPASSERA LE PRIX D   ACHAT DU PRODUIT  ET UNE TELLE RESPONSABILITE SE TERMINERA AVEC L EXPIRATION DE LA P  RIODE DE GARANTIE    Certains   tats et provinces ne permettent pas les limitations de la p  riode de garantie  ou l exclusion ou la restriction des dommages accidentels ou indirects  et  par  cons  quent  les pr  sentes restrictions ne peuvent pas s appliquer  La pr  sente garantie vous donne des droits l  gaux sp  cifiques et peut   tre certains autres droits qui  peuvent varier selon la province  La preuve d achat est exig  e avant qu une r  clamation de garantie ne soit accept  e     SERVICE    LA CLIENT  LE      Sans frais  800  465 7300  Notre   quipe de service    la client  le est disponible pour vous aider avec des questions sur le produit  les adresses des centres de service  et les pi  ces de rechange   Vous pouvez la rejoindre  du lundi au vendredi  de 8h 00    16h 00 HNE  Veuillez avoir le num  ro du mod  le disponible  ainsi que le genre et le style  qui se trouvent sur  l   tiquette    l   int  rieur de votre produit   Veuillez ne pas renvoyer le produit    l endroit de l achat   www airkinglimited com  IL SE PEUT QUE LES PIECES POUR LES PRODUITS DISCONTINUES  OBSOLETES ET AUTRES PRODUITS NE SOIENT
11. being careful not to cut or damage any  electrical or other hidden utilities  Install the side rails on the housing and position the  housing in the previously cut hole so that it is flush with the finished ceiling  Secure the  ends of the rails to the joists  Figure 2      Joist          Figure 3  SECTION 4  Ducting    CAUTIONS ALL DUCTING must COMPLY WITH LOCAL AND NATIONAL  BUILDING CODES     5084461 New 3 12       1  Connect the ducting to the fan   s duct collar  Figure 4   Secure in place using tape or screw  Clamp  Always duct the fan to the outside through a wall or roof cap     Duct  Collar             SECTION 5    Wiring    CAUTIONS make SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE  STARTING INSTALLATION     CAUTIONS att ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE  WITH LOCAL CODES  ORDINANCES  OR NATIONAL ELECTRICAL CODE  IF YOU ARE  UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING  SECURE THE  SERVICES OF A QUALIFIED ELECTRICIAN     NOTE  This unit includes a side access panel for wiring that does not require the removal of the  fan   s blower assembly  If you choose to wire the unit from the inside  you will need to remove the  blower assembly and internal wiring compartment  Both methods are equally effective     ja  External Wire Compartment  Remove the wire compartment cover screw and place  cover in a secure place  Figure 5          Wire  Compartment  Cover    1b  Internal Wire Compartment  Remove the screw holding the venturi in place  Lif
12. epair or replace any part or parts that prove to be defective or replace the whole  product with the same or comparable model    WHAT THIS WARRANTY DOES NOT COVER  This warranty does not apply if the product was damaged or failed because of accident  improper handling or operation   shipping damage  abuse  misuse  unauthorized repairs made or attempted  This warranty does not cover shipping costs for the return of products to Air King for repair or                replacement  Air King will pay return shipping charges from Air King following warranty repairs or replacement   ANY AND ALL WARRANTIES  EXPRESSED OR IMPLIED  INCLUDING  WITHOUT LIMITATION  ANY IMPLIED WARRANTY OF MERCHANTABILITY   LAST ONE YEAR  FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT  WHICHEVER FIRST  OCCURS AND IN NO EVENT SHALL AIR KING   S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE  I  INCIDENTAL OR CONSEQUENTIAL DAMAGES  FROM ANY CAUSE WHATSOEVER  OR  II  REPLACMENT OR REPAIR OF ANY HOUSE FUSES  CIRCUIT BREAKERS OR RECEPTACLES  NOTWITHSTANDING ANYTHING TO  THE CONTRARY  IN NO EVENT SHALL AIR KING   S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT  AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD    Some states and provinces do not allow limitations on how long an implied warranty lasts  or the exclusion or limitation of incidental or consequential damag
13. es  so these  exclusions or limitations may not apply to you  This warranty gives you specific legal rights  You may also have other rights which vary from state to state and province to  province  Proof of purchase is required before a warranty claim will be accepted     CUSTOMER SERVICE     Toll Free  800  465 7300  Our Customer Service team is available to assist you with product questions  service center locations  and replacement parts  They can be reached Monday through  Friday  8am 4pm Eastern  Please have your model number available  as well as the type and style  located on the label inside of your product    Please do not return product to place of purchase   www airkinglimited com    PARTS FOR DISCONTINUED  OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE  DUE TO SAFETY REASONS  MANY ELECTRONIC COMPONENTS  AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT        Description Replacement Part    Fan Housing 581202001  Mounting Rails 581299002  Collar 581299003  Damper 581299004  Blower Assembly 582202001  Blower Wheel 582202003  Wire Compartment Assembly 581202004   6 x 3 8  Screw 581999010   8 x 5 8  Screw 5819990114  Grill 581202005  Grill Springs 581202006                               WO CO N    or  B  co  Po                                 10 32 x 3 8  Ground Screw 551999002  14 ga Ground Wire 581999003   6 x 3 8    Screw 551999010  External Wire Cover 551202007  Knob 591299802  Motor Cap Harness 589202502         
14. eut   tre verrouill    fixer solidement un avis d avertissement   tel qu une   tiquette  au panneau de distribution     AVERTISSEMENT   POUR R  DUIRE LES RISQUES  D   INCENDIE  DE CHOC ELECTRIQUE OU DE BLESSURES  PERSONNELLES OBSERVER CE QUI SUIT      a  Le travail d installation et le c  blage   lectrique doivent   tre  effectu  s par une des  personne s  qualifi  e s  en conformit    avec tous les codes et normes applicables  incluant la  construction relative aux incendies     b  De l   air en quantit   suffisante est requis pour la bonne  combustion et l   vacuation de gaz par le conduit  chemin  e   provenant d   quipement de br  lage au combustible pour pr  venir  un refoulement  Suivre les directives du fabricant de l   quipement  de chauffage et les normes de s  curit   telles que celles publi  es  par la National Fire Protection Association  NFPA  et de la  American Society for Heating  Refrigeration  and Air Conditioning  Engineers  ASHRAE   et de celles des autorit  s locales du code     c  Lors de coupe ou de per  age des murs et plafonds  ne pas  endommager le filage   lectrique et autres utilit  s cach  es     d  Les ventilateurs avec conduits doivent toujours   tre   vacu  s  vers l ext  rieur     e  Si cette unit   doit   tre install  e au dessus d   une baignoire ou  d   une douche  elle doit   tre marqu  e comme appropri   pour  l application et   tre reli  e    un GFCI  disjoncteur de fuite    la  terre    circuit   lectrique prot  g       f  Cette unit   d
15. he fan  Connect the ground  wire from the house to the green wire from the fan housing  Figure 8   Use approved  methods for all connections     Supply from house                         NOTE  The fan   s receptacle wires might need to be pulled outside compartment for connection   Only pull the three loose wires outside of compartment  Additional wires will be present     4  Carefully tuck wire back inside wire compartment and replace wire compartment cover  securing with the screw that was removed earlier     SECTION 6    Completing the Installation    1  Ifthe fan   s blower assembly was removed during the wiring process  reinstall the  blower by reversing the directions in Section 5  Wiring   Step 7b     2  Connect the wire harness by plugging the 3 pin quick connect end into the receptacle  located on the side of the wire compartment cover  Confirm that the 5 pin quick connect  end is plugged into the receptacle from the blower assembly  These cords will only fit  one way into the receptacles  Figure 9                  3  Install the grill by squeezing the two ends of the springs together and installing them up  into the slots on the fan   s housing  Push the grill up into position  Figure 10                  4    SECTION 7    Setting the Humidistat    This fan is equipped with a humidity sensor that automatically turns the fan on when humidity  is above set point and off when humidity is at or below set point  If the fan is operating too  long or not enough  first check
16. ilateur  Connectez correctement le fil de terre  et neutre  le cas   ch  ant   installez le commutateur et le couvercle     3  Apartir de l endroit o   vous avez choisi d acc  der    la bo  te de jonction du ventilateur   connectez le fil blanc de la maison au fil blanc du ventilateur  Connectez le fil de la  position automatique sur l interrupteur mural au fil noir du ventilateur  connectez le fil  de la position manuelle sur l interrupteur au fil rouge du ventilateur  Connectez le fil de  terre de la maison au fil vert du bo  tier du ventilateur  Figure 8   Utiliser des m  thodes  approuv  es pour toutes les connexions       Alimentation provenant de la r  sidence                                  REMARQUE   les fils du r  ceptacle du ventilateur pourraient n  cessiter d     tre tir  s     l ext  rieur du compartiment pour le raccordement  Tirer uniquement les trois fils laches     l ext  rieur du compartiment  Des fils additionnels y sont pr  sents     4  Regrouper soigneusement les fils    l   int  rieur du compartiment pour le raccordement et  replacer le couvercle du compartiment en le fixant avec la vis qui fut enlev  e pr  c  demment     SECTION 6    Compl  tion de l   installation    1  Sil   assemblage de la soufflante du ventilateur a   t   enlev   durant le processus de  raccordement  r  installer la soufflante en inversant les instructions    l   tape 1b de la  Section 5 C  blage     2  Connectez le faisceau   lectrique en branchant l extr  mit   de 3 broches de c
17. la meilleure performance  du d  bit d   air et sonore  il est recommand   que la longueur des conduits et que le  nombre de coudes soient gard  s au minimum et que des conduits rigides isol  s soient  utilis  s  Ce ventilateur n  cessitera au moins 20 3cm   8po  de d  gagement dans le plafond ou le mur  et  s installe au travers de cloison s  che d   une   paisseur  de jusqu    1 9cm 3 4po   Le ventilateur s installe entre  40 6cm ou 61cm  16po ou 24po  au centre des solives     l   aide des quatre  4  traverses de montage incluses     3  S  lectionner l   alv  ole d  fon  able la mieux appropri  e  et l enlever    l   aide d   un tournevis    lame plate     Figure 1   S  SECTION 2    Nouvelle Construction    Figure 1    1  Installer les traverses sur le chassis et positionner le ch  ssis pr  s de la solive  Aligner  le ch  ssis pour qu il soit    effleurement avec le plafond fini  Fixer les extr  mit  s des  traverses avec des clous ou des vis  non comprises  aux solives et glisser le ch  ssis     sa position finale  Figure 2                  Traverses de  Montage                SECTION 3    Construction Existante    1  Placer le ch  ssis en position entre les solives et tracer un contour sur le mat  riau du plafond   Figure 3   Mettre le ch  ssis de c  t   et d  couper l ouverture  en prenant soin de ne pas couper  ou endommager des c  bles   lectriques dissimul  s ou autres utilit  s  Installer les traverses  sur le ch  ssis et positionner le ch  ssis dans le trou perc   p
18. mbustion and exhausting  of gases through the flue  chimney  of fuel burning equipment  to prevent back drafting  Follow the heating equipment  manufacturer   s guideline and safety standards such as those  published by the National Fire Protection Association  NFPA    and the American Society for Heating  Refrigeration  and Air  Conditioning Engineers  ASHRAE   and the local code authorities     When cutting or drilling into wall or ceiling  do not damage  electrical wiring and other hidden utilities     d   e     Ducted fans must always be vented to the outdoors     If this unit is to be installed over a tub or shower  it must be  marked as appropriate for the application and be connected to a  GFCI  Ground Fault Circuit Interrupter    protected branch circuit     This unit must be grounded     To avoid motor bearing damage and noisy and or unbalanced  impellers  keep drywall spray  construction dust  etc  off power unit     NEVER place a switch where it can be reached from a tub or  shower     Suitable for use with electronic speed control device     Do not install into ceilings thermally insulated to a value greater  than R40     CAUTION  FOR GENERAL VENTILATING USE ONLY  DO NOT  USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND  VAPORS     WARNING  DO NOT USE IN KITCHENS     k     Read all instructions before installing or using exhaust fan     SAVE THESE INSTRUCTIONS    WWW AIRKINGLIMITED COM    1of8    INSTALLATION INSTRUCTIONS    CAUTIONS make sure POWER IS SWITCHED
19. oit   tre mise    la terre     g  Pour   viter des dommages aux roulements des moteurs et ou  des h  lices bruyantes ou d  s  quilibr  es  emp  cher la poussi  re  de cloison s  che  poussi  re de construction  etc   d atteindre  l   unit   de puissance     h  NE JAMAIS placer un interrupteur    un endroit qui puisse   tre  atteint de la baignoire ou de la douche     i  Appropri   pour l   usage avec le dispositif de commande    lectronique de vitesse     j  N   installez pas sur des plafonds thermiquement isol  s    une  valeur plus grande que R40     AVERTISSEMENT   POUR USAGE DE VENTILATION  GENERALE EXCLUSIVEMENT  NE PAS UTILISER POUR EVACUER  DU MATERIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES     AVERTISSEMENT   NE PAS UTILISER DANS LES CUISINES    k  Bien lire toutes les instructions avant d   installer ou d   utiliser le  ventilateur d     vacuation     CONSERVER CES INSTRUCTIONS    5084461 New 3 12    WWW AIRKINGLIMITED COM 5of8    INSTRUCTIONS D   INSTALLATION  AVERTISSEMENT   vous ASSURER QUE L ALIMENTATION EST    COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION     SECTION 1    Pr  paration du Ventilateur d     vacuation    1  Sortir le ventilateur de sa boite et confirmer que toutes les pi  ces sont pr  sentes  En  plus du ventilateur d   vacuation vous devriez avoir   1   Grille  4   Traverses de Montage  1   Ensemble de clapet  attach     1   Feuillet d   instructions   s  curit      2  Choisir un emplacement pour votre ventilateur  Pour assurer 
20. onnexion  rapide dans la prise situ  e sur le c  t   du couvercle du compartiment de fil  Assurez vous  que l extr  mit   de 5 broches de connexion rapide est branch  e dans la prise du ventilateur   Ces fils ne peuvent   tre ins  r  s que dans un seul sens dans les prises Figure 9               Trouble Cause Possible    1  Le ventilateur ne fonctionne pas lorsque  l interrupteur est    la position en marche  peut   tre d  cle nch     1b  La fiche de raccord du moteur n   est    pas connect  e     1d  La moteur est terminee    1a  Un fusible peut   tre grill   ou un disjoncteur    1c  Le c  blage n   est pas raccord   correctement     3  Installer la grille en pressant ensemble les deux extr  mit  s des ressorts et en les installant  dans les fentes du ch  ssis du ventilateur  Pousser la grille en position  Figure 10               Figure 10       4 Restaurer l alimentation et tester votre installation     SECTION 7    R  glage de l   humidostat    Ce ventilateur est   quip   d un capteur d humidit   qui allume automatiquement le ventilateur   ou hausse la vitesse pour les mod  les    deux vitesses   lorsque l humidit   est sup  rieure au  point de consigne  ou baisse la vitesse pour les mod  les    deux vitesses  lorsque l humidit    est inf  rieure ou   gale au point de consigne  Si le ventilateur fonctionne trop longtemps ou  pas assez  v  rifiez d   abord le point de consigne du capteur d humidit    Dans le cas o   le  niveau d humidit   ambiante de la pi  ce s   l  ve plu
21. r  c  demment afin qu il soit     effleurement avec le plafond fini  Fixer les extr  mit  s des traverses aux solives  Figure 2      Solive             Figure 3    SECTION 4    Conduits    AVERTISSEMENT   rous LES CONDUITS DOIVENT   TRE    CONFORMES AUX CODES DU B  TIMENT LOCAUX ET NATIONAUX     5084461 New 3 12    1  Raccorder le conduit au collet de conduit du ventilateur  Figure 4   Fixer en place     l   aide de ruban ou de serre joint  Toujours   vacuer le ventilateur vers l ext  rieur au  travers de chapeau mural ou de toit     Conduits    Collet du  Conduit             SECTION 5    Cablage    AVERTISSEMENT   vous ASSURER QUE L ALIMENTATION EST    COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION     AVERTISSEMENT   toutes LES CONNEXIONS DOIVENT   TRE FAITES  EN CONFORMIT   AVEC LES CODES   LECTRIQUES LOCAUX OU NATIONAUX  SI VOUS  N   TES PAS FAMILIER AVEC LES M  THODES D INSTALLATION DE CABLAGE   LECTRIQUE   RECOURREZ AUX SERVICES D UN ELECTRICIEN QUALIFI       REMARQUE   cette unit   poss  de un panneau d   acc  s lat  ral pour le c  blage qui ne requiert  pas l enl  vement de l assemblage de la soufflante du ventilateur  Si vous choisissez de  raccorder l unit   par l   int  rieur  vous aurez besoin d enlever l assemblage de la soufflante et le  compartiment de c  blage int  rieur  Les deux m  thodes sont   galement efficaces     ta  Compartiment de C  blage Ext  rieur   enlever la vis du couvercle du compartiment    c  blage  et mettre ce couvercle dans
22. s haut que le niveau pr  r  gl    le ventilateur  s   allumera  m  me si la salle n   est pas occup  e  Ceci aide      viter les conditions qui m  nent     la croissance de moisissures     AVERTISSEMENT   vous ASSURER QUE L ALIMENTATION EST    COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION     1  Pour r  gler le niveau d  sir   d humidit   de la salle  enlevez la grille et localisez le cadran  de I   humidostat situ   sur le couvercle du compartiment de fil     2   R  glez le cadran    l   humidit   relative que vous vous voulez que le ventilateur  maintienne  habituellement entre 50  et 80   Les climats humides exigeront des  r  glages plus   lev  s que les climats secs  Lorsque le niveau d humidit   de la salle est  inf  rieur    ce r  glage  le ventilateur restera   teint  Lorsque le niveau d humidit   monte     ce r  glage  le ventilateur s   allumera et fonctionnera jusqu      ce que le niveau d humidit    tombe au dessous de ce r  glage     3  R  installer la grille et r  tablir le courant     SECTION 8    Utilisation et entretien    AVERTISSEMENT   vous ASSURER QUE L ALIMENTATION EST    COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION     1  Nettoyage de la grille   Retirer la grille et utiliser un d  tergent doux  tel que du liquide  pour la vaisselle  puis s  cher    l   aide d   un chiffon doux  NE JAMAIS UTILISER D   ABRASIF  OU DE POUDRE    RECURER  S  cher compl  tement la grille avant de la r  installer  Pour  r  installer la grille
23. t the  venturi up and at an angle to slide it out of the housing  Figure 6   Remove the wire  compartment cover screw and place the cover in a secure place  Figure 7                  Venturi             Figure 6       Humidity Set  Point Knob    Wire Compartment  Cover       NOTE  If the fan motor plug is connected to the fan housing receptacle  unplug so the blower  assembly can be completely removed     WWW  AIRKINGLIMITED COM 20f8    2  For proper operation the humidity sensing fan will require a 3 way switch  not included    Run wiring between the fan and the switch location  Make sure you leave enough wiring  in each box to make the connections  At the switch box connect the Black wire from  the house to the common terminal of the switch  Connect the black wire from the fan to  one of the switched terminals on the switch  This position will energize the automatic  mode and the fan will energize upon a rise in humidity  Connect the Red wire from the  fan to the other switched terminal on the switch  This position will activate the Manual  On feature and energize the fan  Properly connect the ground and neutral  if applicable   mount the switch and the cover     3  From where you have chosen to access the fan   s junction box  connect the white wire  from the house to the white wire from the fan  Connect the wire from the automatic  position on the wall switch to the black wire from the fan  connect the wire from the  manual On position on the switch to the red wire from t
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Multimedia DVD Player Bedienungsanleitung Instruction  PM Classic Forward Controls- Updated    calibrador de nível sonoro msl-1326 manual de instruções  American Standard Green Tea Deck-Mount Bath Filler 7010.900 User's Manual    Copyright © All rights reserved. 
   Failed to retrieve file