        Delta Breez RAD80L Instructions / Assembly
         Contents
1.                                                 b  Insert the fan body   between joists  Make sure  the fan body is level and perpendicular with the  joist  and flush with ceiling surface           c  Allow for thickness of the ceiling board used in  your application  Fan body   should be flush  with ceiling board                                               d  Secure the suspension brackets to joists with the  wood screws        e  Secure the suspension brackets to fan body    with the short machine screws G     f  Remove tap before connecting the duct as  shown in Figure 1 2              Hardware  Q Short Machine Screw  M4x12  Qty 4    deg    G Wood Screw     4x14  Oty 8    m                Model  RAD80L 6    A DELTA    d   breez       ASSEMBLY INSTRUCTIONS    2  Connecting the duct    A CAUTION  All ducting must comply with local  and national building codes     a  Insert the duct into the duct connector and tape    all duct work connections to make them secure  and air tight     b  Do not install the unit where ducts are configured  as shown in Figure 2 2  Install the duct with a  gradient of 1   2   to the outside     3  Remove the fan junction box cover    Using wire  nuts  not supplied   connect house wires to fan  wires   as shown in the wiring diagram on page  10  Reattach fan junction box cover                      Duct shrink          e e    Too many elbows    Turning angle too large    Elbow near the body    Body    S S       Minimum 18 in                        
2.      Model  RAD80L    LA DELTA agp breez  ASSEMBLY INSTRUCTIONS    4  Completing the Installation       a  Check the plug from the fan into the receptacle  marked    Vent       Check the plug from the heating unit into the  receptacle marked    Heat                         b  Plug the Light Connector into the receptacle  marked    Light          c  Install the Grille Assembly   into the Fan  Body   using the Machine Screw         CAUTION  Do not use Wood Screw  in place of  Machine Screw                Wood screw    O 4x14   Machine screw  M5x14                 Model  RAD80L 8    d   breez    A RELA    ASSEMBLY INSTRUCTIONS    d  Install a 26W max   type GU 24 fluorescent                       F                lamp   into Grille Assembly        e  Install the Light Lens   into Grille Assembly        Model  RAD80L    LA nELTA d   breez    WIRING INSTRUCTIONS  A CAUTION     e Make sure power is switched off at service panel before BLU WHT  T  n T VW  starting installation  ANG18 ANG18                      All electrical connections must be made in accordance with  local codes  ordinances  or national electrical code  If you T e a e  are unfamiliar with methods of installing electrical wiring    secure the services of a qualified electrician                    BLK  TCH e WHT  AWG18 AWG18  BLK    A warning  t        This unit must be wired on a separate 20 amp circuit                                                             HOUSE ELECTRICAL BOX HEATER ELECTRICAL BOX         If
3.  to   Wall cap    N  with built in  reduce backdrafts  Seal gap Caulk termination damper   around to duct  housing    DIMENSION REQUIREMENTS    Ceiling Ceiling Ceiling Housing Housing Housing  Opening  L  Opening  W  Opening  H  Dimension  L    Dimension  W    Dimension  H        WARNING    Be careful to cut hole exactly  If the hole is too big  the fan grille will not hide it     Model  RAD80L 4    LA DELTA agp breez  ASSEMBLY INSTRUCTIONS    Unpacking  Carefully remove unit from carton  Remove the foam in the housing  Refer to the Package Contents list on page 2  to verify that all parts are present     Installing the unit  Installing the fan body in an existing building requires an accessible area  attic or crawl space  above the planned  installation location and existing duct and wiring     A CAUTION  Check area above installation location to ensure that     e Duct work can be run and the area is sufficient for proper ventilation     Wiring can be run to the planned location   e No wiring or other obstructions can interfere with installation     A WARING     e To reduce the risk of fire  do not store or use gasoline or other flammable vapors and liquids in the vicinity of the  heater     5 Model  RAD80L    LA DELTA agp breez  ASSEMBLY INSTRUCTIONS    1  Mounting the fan between the joists w       a  Insert either the 12 in  suspension brackets    or 14 in  suspension brackets   to the duct side  and back of the fan body     depending on the  distance between the joists  
4.  your house wires do not match these colors  you must  determine what each house wire represents before    connecting and you may need to consult an electrical       contractor to determine this safely  en GROUND    ON OFF SWITCH TEE  bare    purchase separately           1  Follow all local electrical and safety codes         H ag QO  2  Never place a switch where it can be reached from a tub A  or shower                             3  Using wire nuts  not included   connect house power wires  to fan wires     BR   LIGHT HEATER VENT    4  14 AWG  2 1 mm   is the smallest conductor that may be SEHR  used for branch circuit wiring  Each power wire  light  fan     heater  must have its own switch to operate independently                                         5  For supply connections  use wire rated for at least 90 C   See wiring diagram for wire size        OPERATING INSTRUCTIONS    A CAUTION  Failure to secure the reflector screws may result in a rattling or humming noise     A WARNING     This unit must be properly installed before it is used  Follow instructions for cleaning  user maintenance and  operations recommended by the manufacturer  such as lubrication or non lubrication  Any other servicing should be  performed by an authorized service representative     1  Turn on the light switch to turn on the light bulb   2  Turn on the vent switch to operate the fan mode     3  Turn on the heat switch to operate the heater mode     Model  RAD80L 10    A DELTA    CARE AND MAI
5. 40      This is required for installations in Canada only        Duct work should be installed in a straight line with minimal    bends       Duct work size must be a minimum of the discharge    and should not be reduced  Reducing the duct size can  increase fan noise       This ventilating bath fan is intended for residential use only    in 1 2 family dwellings       Never place a switch where it can be reached from a tub or    shower       Make sure that the electric service supply voltage is AC    120 V  60 Hz       Always disconnect the power source before working on or    near the unit       This unit is designed and tested to be a supplemental    heater for use with a timer or a switch  It is not intended  to be used as a primary source of heat  or controlled by a  thermostat       To avoid motor bearing damage and noisy and or    unbalanced impellers  keep drywall spray  construction  dust  etc   off power unit       Provide a separate 20 AMP circuit     This product is designed for ceiling installation only  Do not    mount this product in a wall       Install in ceiling only  at least 6 in  from any wall     For greatest efficiency  install heater so heat is directed toward    tub or shower area  Avoid directing toward walls or windows       Do not install less than 8 ft   2 4 m  from the floor     Model  RAD80L    LA DELTA agp breez  PREPARATION    Tools Required for Assembly  not included   Hammer  Flathead Screwdriver  Wire Nuts  Nails  Duct Tape   Phillips Head S
6. LA DELTA d   breez    VENTILATION FAN WITH  LIGHT AND HEATER       MODEL RAD80L  TABLE OF CONTENTS  Package Contents 2  Important Instructions 3  Preparation 4  Assembly Instructions 6  Wiring Instructions 10  Operating Instructions 10  Care and Maintenance 11  Troubleshooting 13  Dimensions 14  Product Specifications 14  Warranty 15    READ AND SAVE THESE INSTRUCTIONS    Please read and understand this entire manual before attempting to assemble   operate  or install the product     Address  4405 Cushing Parkway  Fremont  CA 94538  US Toll Free Number  1 888 979 9889    LA DELTA agp breez  PACKAGE CONTENTS    PART   DESCRIPTION   QTY    Grille Assembly       v  Ip   26W max   type GU24  ot    Kg    Fluorescent Lamp     e Suspension Bracket      e   Suspension Bracket II           HARDWARE CONTENTS    Short Machine Screw  M4x12  Qty 4    Machine Screw  M5x14  Qty 1    Jam    Wood Screw     4x14  Qty 8         Model  RAD80L 2    A DELTA    d   breez    IMPORTANT INSTRUCTIONS    When using electrical appliances  basic precautions should  always be followed to reduce the risk of fire  electric shock   and injury to persons  including the following      Read all instructions before installing or using this heater      Extreme caution is necessary when heater fan is used  by or near unattended children  and   or persons with  disabilities or limitations      Do not operate heater if it malfunctions  Disconnect power  at service panel and have heater inspected by reputable  electri
7. NTENANCE    d   breez       Routine maintenance must be done every year     A CAUTION        Make sure power is switched off at service panel  before servicing the unit     To replace lamp      Use type GU24 fluorescent lamp rated to 26Watts  only   e Allow lamp to cool before replacing     To clean fan  disassemble using the following steps     1  Remove Light Lens G cover     2  Remove 26W max   type GU24 Fluorescent Lamp         3  Remove Machine Screw G     Hardware  G Machine Screw  M5x12  Qty 1    m             11 Model  RAD80L    LA DELTA agp breez  CARE AND MAINTENANCE    4  Remove Grille Assembly       5  Remove dust and dirt from the Fan Body   with a  vacuum cleaner   Do not use abrasive cloths  steel wool pads  or  scouring powders  Never use solvents  thinner or  harsh chemicals when cleaning the fan     Vacuum  cleaner       6  Replace Grille Assembly   back onto Fan Body      Please refer to Completing the Installation   Follow the steps on pages 8 9 to assemble fan back  together        Model  RAD80L 12    IN NELTA    d   breez    TROUBLESHOOTING       PROBLEM    The fan is not turning on    The fan seems louder  than it should    The fan is not clearing  the room    POSSIBLE CAUSE      Power off    Faulty switch      Faulty wire connection      CFM      Damper not working    properly or damaged      Bend in duct too close    to fan discharge      Fan discharge    reduced to fit smaller  duct      Fan body not securely    attached      Insufficient intake    a
8. cian before reusing      Do not use outdoors      To disconnect heater  turn controls to off  and turn off  power to heater circuit at main disconnect panel      Do not insert or allow foreign objects to enter any  ventilation or exhaust opening as this may cause an  electric shock or fire  or damage the heater      To prevent a possible fire  do not block air intakes or  exhaust in any manner      Aheater has hot and arcing or sparking parts inside  Do  not use it in areas where gasoline  paint  or flammable  vapors or liquids are used or stored      Use this heater only as described in this manual  Any other  use not recommended by the manufacturer may cause  fire  electric shock or injury to persons      SAVE THESE INSTRUCTIONS   SAFETY INFORMATION    Please read and understand this entire manual before  attempting to assemble  operate or install the product      Follow all local safety and electrical codes as well as NEC   National Electrical Code  and OSHA  Occupational Safety  and Health Act       This unit must be properly grounded      Always disconnect the power supply prior to servicing the  fan  motor or junction box      Do not bend or kink the power wires  Protect from sharp  edges  oil  grease  hot surfaces  chemicals or other objects      Do not install where the room air temperature will exceed  40  C  104  F       Do not install over a tub or mount in a shower stall  enclosure      Do not use to exhaust hazardous or explosive vapors      Do not install in a c
9. crewdriver  Utility Knife  Helpful Tools  not included   Electric Drill  Drill Bits    WARNING  Turn off electricity at breaker box before beginning installation     e Before installation  provide inspection and future maintenance access at a location that will not interfere with  installation work       You may need the help of a second person to install this fan  one person on the attic side and one on the room side    s Remove ceiling section using dimensions provided below  Be careful to cut hole exactly  If hole is too big  the fan  grille will not hide it        e Determine the distance between your joists     Spacing A on center joists  16 0 inches    19 2 inches  24 0 inches                Note  Installations may vary depending on how the previous bath fan was installed  Supplies necessary for the  installation of your bath fan are not all included  However  most are available at your local home improvement or  hardware store                            e Proper insulation around the fan to minimize building heat Roof cap     j WI uiit Iin  loss and gain  SSS Ge  s Locate unit above  GFCl protected circuit required  or Short piece of flexible  within 5 feet of the shower head  duct helps alignment  e Locate unit away from heating or cooling sources  sound  s The fan will operate most efficiently when located where Fan housing  the shortest possible duct run and minimum number of Su or  elbows will be needed  s     e Use a roof cap or wall cap that has a built in damper
10. glect  improper transportation or storage  improper testing  improper installation  improper operation   improper use  improper maintenance  improper repair  improper alteration  improper modification  tampering or  accident of products or parts thereof  or unusual deterioration or degradation of products or parts thereof due to  a physical environment beyond the requirements of products    specifications     Address  4405 Cushing Parkway  Fremont  CA 94538  US Toll Free Number  1 888 979 9889    15 Model  RAD80L    Area dip breez    
11. irflow within room      Insufficient CFM    13    CORRECTIVE ACTION      Make sure power supply is on     Test or replace switch       Check wire in switch box       Be sure the CFM rating on the fan matches the    size of your room       Check damper to ensure it is opening and closing    properly  If the damper has become damaged   please call Customer Service       Be sure you do not have any sharp bends in duct    closer than 18 in  to the fan discharge       Use recommended size ducting to reduce fan    noise       Be sure the fan is securely attached to your ceiling    joists       Be sure a door or window is slightly ajar or opened    to allow airflow  The fan is not able to draw air out  of the room without enough airflow to draw in from       Be sure the CFM rating on the fan matches the    requirements for your room size        Model  RAD80L    LA nELTA d   breez    16 81 5 50                10 63  8 25                                                                1 45                               Unit  inch       14 38      PRODUCT SPECIFICATIONS    SPECIFICATIONS    Model No  RAD80L    TYPE IC INHERENTLY PROTECTED   THERMALLY PROTECTED L           Dimension    Ceiling opening length 14 62 in     Housing dimension length 14 38 in       Model  RAD80L 14    LA nELTA d   breez    DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY    Delta Electronics Inc    Delta Electronics     warrants to the original consumer purchaser in the USA that the Breez  ventilation fan produc
12. ooking area      Do not install this fan vertically in a wall    Use this unit in the manner intended by the manufacturer   If you have any questions  please call the manufacturer   customer service number located on last page        Installation work must be carried out by a qualified  person s  in accordance with all local and safety codes    including the rules for fire rated construction  For use in  non fire rated installations only       Sufficient air supply is required for proper combustion    and the exhaustion of gases through the chimney  flue  of  fuel burning equipment to prevent back drafting  See the  standards of NFPA  National Fire Protection Association   and ASHRAE  American Society for Heating Refrigeration  and Air Conditioning Engineers  and the local building code  authorities       Exercise care to not damage existing wiring when cutting    or drilling into walls or ceilings       Fans should always be vented to the exterior and in    compliance with local codes       Do not use this fan with any solid state control device such    as a dimmer switch  Solid state controls may cause harmonic  distortion  which can cause a motor humming noise       Prior to service or cleaning this unit  shut off power supply    at the panel and lock to prevent the power from being  turned on  If the panel cannot be locked  clearly mark the  panel with a warning tag to prevent the power from being  turned on       Do not install in a ceiling with insulation greater than R
13. ts will be free from defects in material or workmanship  This warranty is limited to three  3   years from the original date of purchase     Limitations and Exclusions    1     NO GG      During the warranty period  a replacement for any defective product will be supplied free of charge for installation  by the consumer  The warranty provided herein does not cover charges for labor or other costs incurred in the  troubleshooting  repair  removal  and installation service       All returns of defective parts or products must include the product model number  and must be made through an    authorized Delta Electronics distributor  Authorized returns must be shipped prepaid  Repaired or replacement  products will be shipped by Delta Electronics F O B  shipping point       Delta Electronics shall not be liable for any indirect  incidental  consequential  punitive  or special damages    arising out of or in connection with products use or performance  regardless of the form of action whether in  contract  tort  including negligence   strict product liability or otherwise       This warranty does not extend to fluorescent lamp starters and tubes     The warranty does not cover if user does not comply with manufacturer   s installation manual     To qualify for warranty service  you must notify Delta Electronics at the address or telephone number below       Delta Electronics shall have no liability to the original owner user with respect to any defect caused by abuse     misuse  ne
    