Panasonic FV-05VQ5 Instructions / Assembly
Contents
1. C we 1 Fan body A 7 Finish ceiling work Ceiling hole should be aligned with the inside edges of the flange Fig 5 IMPORTANT Remove the tapes from louver and springs before installation As shown below Unit inches mm After finishing the ceiling job fill gap between flange and ceiling with caulk or other sealant to prevent air leakage Fig 5 8 Insert mounting springs into slots as shown and mount grille to fan body Fig 6 Notes Suitable for use with solid state speed controls Solid state speed controls may cause harmonic distortion which can cause a motor humming noise 6 Slot Mounting spring Ceiling Grille Fig 6 INSTALLATION II SUSPENSION BRACKETS MOUNTING VM A Joist situation DE o Suspension bracket III or IV Spacing A is 16 inches f 406 mm to 24 inches n 609 mm on center joists eal 4 eS Fan body Suspension bracket I 1 If the spacing A is 16 inches 406 mm to 24 inches 609 mm on center joists please follow the m installation step as below sis Fig 7 2 Insert the suspension bracket I and II into the fan Suspension bracket III body and suspension bracket III or IV into the 16 ne 406 mm a adaptor
2. Part name No Part name 1 Blade 5 Fan body 2 Grille 6 Damper 3 Junction box 7 Suspension bracket 4 Adaptor 8 Bracket cover WIRING DIAGRAM Fuse in motor Fuse type FV 05VQ5 237 F 114 C FV 08VQ5 237 F 114 C FV 11VQ5 237 F 114 C FV 15VQ5 273 F 134 C I White Neutral _ gt Black Live Vent gt Power Supply l AC120V 60Hz Green Earth ground_ _ Earth ground Junction box Fan body INSTALLATION I JOIST MOUNTING I A Joist situation Spacing A is 16 inches f f l 406 mm to 24 inches 609 mm on center joists Joists l l If the spacing A is 16 inches 406 mm to 24 inches 609 mm on center joists please follow the installation step as below Fan body Suspension IMPORTANT Remove the tape from damper and adaptor before installation As shown below N Insert the suspension bracket I and II into the fan body Select the suspension bracket connection holes as shown below Fig 1 Suspension bracket connect method Suspension bracket I and II connect with screw I as shown below Unit inches mm 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 Suspension bracket II X Suspension bracket I rewI WT C STA 2X6 3 Install the suspension
3. Select the suspension bracket connection Serao bracket AS Fr holes as shown below Fig 7 Fig 8 24 inches 609 mm horizental joist Joists Suspension bracket connect method Suspension bracket I and II connect with screw I as shown below Unit inches mm 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 211 4 23 1 2 540 597 6 Long screws Suspension ST4 2X20 bracket I Suspension Screw I ST4 2X6 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 A 21 2 41 5 64 107 5 1 27 1 5 140 183 j 3 Install the suspension bracket to joists by using long screws ST4 2X20 Fig 8 and secure it to the fan body by using screw II ST4 2X14 Fig 9 0 1 0 25 4 Unit inches mm Fig 8 INSTALLATION II SUSPENSION BRACKETS MOUNTING CONTINUED 4 Follow steps 4 to 8 of installation I page 6 to complete the installation work Screw II ST4 2X14 Fig 9 INSTALLATION III JOIST MOUNTING II i B i Joist situation Spacing B is ie 10 1 2 inches 266 mm to A 11 1 2 inches 292 mm N Joists on joists 1 If the spacing B is 10 1 2 inches 266 mm to 11 1 2 inches 292 mm on joists please follow the installation step as below 2 Secure 4 long screws ST 4 2X20 at flange of frame Fig 10 3 Follow steps 4 to 8 of installation I page 6
4. bracket and the flange of fan body to joists by using long screws ST4 2X20 and secure it to the fan body by using screw II ST4 2X14 Fig 2 bracket I Suspension bracket II Fig 1 Joists Suspension bracket I amp II 4 Long screws ST4 2X20 io Screw II 2 Long screws ST4 2X14 ST4 2X20 Fig 2 INSTALLATION I JOIST MOUNTING I CONTINUED 4 Install a circular duct and secure it with clamps or wire ties and seal it with mastic or approved duct tape Fig 3 5 Remove junction box cover and secure conduit or stress relief to junction box knock out hole Fig 3 6 Refer to wiring diagram below Follow all the local electrical safety codes as well as the National Electrical Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires Fig 4 CAUTION Mount junction box cover carefully so that lead wires are not pinched WIRING DIAGRAM Conduit Junction box cover Circular duct Duct tape Fig 3 Earth ground to green Wire nut Live to black Ventilating fan Capacitor gig White Neural power L 4 Black Live Vent Supply 1 gt AC120V Fuse in motor Green Earth ground 60Hz Fuse type FV 05VQ5 237 F 114 C 1 FV 08VQ5 237 F 114 C Earth ground Junction box FV 11VQ5 237 F 114 C f FV 15VQ5 273 F 134
5. insulation can be placed faced tape directly over the fan housing in the attic 2 3 feugi E BEIOIS BIDONM In attic installation Panasonic fans and fan light combination caulk box to drywall units do not create excessive heat that is x i ria a common problem with recessed light 4 fixtures or some competitors fan light Short piece of flexible duct helps combinations Our efficient cool running alignment and absorbs sound Insulation Clamps plus mastic or approved motors and our fluorescent lamp do not foil faced tape at all flex joints Foil tape tightly covers all metal create enough ambient heat to be subjected duct joints glue PVC joints Fig 15 to these limitations SPECIFICATIONS HVI Certified performance based on HVI Procedures 915 916 and 920 PRODUCT SERVICE Warning Concerning Removal of Covers The unit should be serviced by qualified technicians only Your product is designed and manufactured to ensure a minimum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7292 USA or 1 800 669 5165 Canada 10 Air Voltage Frequency d Noise ee Speed ane Weight Model No direction V Hz Geen sones ND 9 mm CFM Ib kg FV 05VQ5 Exhaust 120 60 4 0 3 11 0 730 50 9 9 4 5 FV 08VQ5 Exhaust 120 60 4 0 3 14 5 815 80 9 9 4 5 FV 11VQ5 Exhaust 120 60 4 0 3 22 0 960 110 9 9 4 5 FV 15V
6. Panasonic Ventilating Fan INSTALLATION INSTRUCTIONS Model No FV 05VQ5 FV 08VQ5 FV 11VQ5 FV 15VQ5 READ AND SAVE THESE INSTRUCTIONS Thank you very much for having purchased our Ventilating Fan Please read these instructions carefully before attempting to install operate or service the Panasonic Ventilating Fan Failure to comply with instructions could result in personal injury and or property damage Please retain this booklet for future reference Table of Contents Unpacking X xsos reta n e RINT asin ncnconlntpinynaientarn ajeca leanne ieianstuia n etitwtalahu ean atten T 2 Supplied Accessories MM HH 2 Description 2 General Safety lIrifOrmmaltlOTn aeisesssssessosddnencdesssssdnsv EEA Ra NM MNA M M RENE 3 Dirienslolls 22 2 9 2 2 0 sei i emda nasus S ERE ES zx FF EI EEEE E DI 4 Wiring Diagram e E 4 Installation I Joist Mounting I HR 5 6 Installation II Suspension Brackets Mounting E Rte IM SaPaaietadions TETUER 7 8 Installation III Joist Mounting II NEEESE E E EERE Vaid sesame Wine BERUF ND Ee ES UU TE NE 8 Maintenance Cleaning mem eee e eene 8 9 Practical Guide To Installation emen 9 Specifications enne Ie enhn nnn hnenen nennen 10 Product Service VEREGURG au Rr YETERIE E FEET FK FRE RON GTEC T 10 UNPACKING Unpack and carefully remove the unit from carton Refer to the Supplied Accessories l
7. Q5 Exhaust 120 60 6 0 3 28 5 700 150 11 2 5 1 Panasonic Corporation of North America One Panasonic Way Secaucus New Jersey 07094 WWVW panasonic com Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario LAW 2T3 www panasonic ca A1002 0 08VQ54020 Printed in China
8. er objects 0 9 Do not kink the power cord Prohibited f Ad Do not install the unit where ducts are configured as shown in Fig A aad Provide make up air for proper ventilation Q Fig A Cooking area Do not install above oo Ot s this area 1 CAUTION a D Ss For general ventilating use only Do not use to exhaust S hazardous or explosive materials and vapors Ng ka 2 Not for use in cooking area Fig B Cooking Floor 3 This product must be properly grounded ra Fig B WARNING To reduce the risk of fire electric shock or injury to persons observe the following 1 2 Use this unit only in the manner intended by the manufacturer If you have any questions contact to the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standa
9. ist to verify that all parts are present SUPPLIED ACCESSORIES Part name Appearance Quantity Part name Appearance Quantity Screw I ST4 2X6 Grille Screw II ST4 2X14 Suspension bracket I Long screw bracket II m Suspension ES Installation bracket III instructions Suspension A Warranty bracket IV S sheet DESCRIPTION These Panasonic ventilating fan models are listed by UL under UL file No E78414 These Panasonic ventilating fan models use a sirocco fan driven by a capacitor motor The motor is designed to have an extended service life with reduced energy consumption It also incorporates a thermal cutoff for safety The grille covering the fan body is a spring loaded quick remove type A damper for preventing air counterflow is provided The blower uses a high capacity sirocco fan developed to reduce the noise level GENERAL SAFETY INFORMATION 104 F 40 C Do not install this ventilating fan where interior room temperature may exceed E 2 Make sure that the electric service supply voltage is AC 120V 60Hz Prohibited 4 3 Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Q uif Always disconnect the power source before working on or near the fan motor junction box Prohibited Protect the power cord from sharp edges oil grease hot surfaces chemicals or oth
10. rds such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit These models are UL listed for tub and shower enclosures Not to be installed in a ceiling thermally insulated to a value greater than R40 This is required for installation in Canada only DIMENSIONS FV 05VQ5 FV 08VQ5 FV 11VQ5 FV 15VQ5 Unit inches mm 7 8 22 5 uid m pe 4 3 5 116 1 Es z 7 r Inl m S s O 83 8E _ pe her OH age M 1 7 a a 5 1 8 130 6 3 8 163 13 330 71 2 190 s The dimensions in square brackets refer to FV 15VQ5 which are different g from FV 05 08 11VQ5 10 1 4 260 3 1 2 90 3 7 8 100 No
11. to complete the installation work MAINTENANCE CLEANING 4 Long screws ST4 2X20 Fig 10 WARNING Disconnect power source before working on unit Routine maintenance must be done every year CAUTION 1 Never use gasoline benzene thinner or any other such chemicals for cleaning the ventilating fan 2 Do not immerse motor in water when cleaning 3 Do not soak resin parts in water over 140 F 60 C 1 Remove grille Squeeze mounting spring and pull down carefully Fig 11 hn N me Slot Mounting spring Grille Fig 11 MAINTENANCE CLEANING CONTINUED 2 Clean grille Don t put into hot water Use non abrasive kitchen detergent wipe dry with clean cloth Fig 12 Fig 12 3 The grille should be dry after cleaning Ceiling 4 Remove dust and dirt from fan body using a vacuum cleaner Fig 13 Vacuum N cleaner Fig 13 5 Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Fig 14 y y Wipe ary g Ceiling 6 Replace grille Fig 14 Properly insulate the area around the fan rere tl H s H our inch or six inch root Jack wall Cap NX to minimize building heat loss and gain orsoffit vent with backdraft damper Ww Fig 1 5 Mechanically connect duct to termination and seal with mastic or approved foil Loose fill or batt