Spruce 28206 Instructions / Assembly

image

Contents

1. AS PROVIDED ABOVE For service under this Warranty contact Spruce for a Return Material Authorization RMA number and shipping information No returns can be accepted without an RMA If factory return is required the customer assumes all shipping cost to and from factory Spruce Environmental Technologies Inc 3 Saber Way Ward Hill MA 01835 TEL 978 521 0901 FAX 978 521 3964 Record the following information for your records Serial No Purchase Date Page 8 of 8 IN018 Rev M
2. C Common Ground Green or Grn Yel Page 2 of 8 IN018 Rev M INSTALLATION INSTRUCTIONS INO18 Rev M RB Series RB110 p n 23046 1 28128 T RB275 p n 23034 1 28115 RB300 p n 23022 1 28088 D r u G e RB350 p n 23023 1 28261 RB400 p n 23052 1 28206 RB500 p n 23053 1 28207 1 0 Mounting The Spruce RB Series fans may be mounted at any angle without affecting performance although the vertical mounting position shown in Fig 1 is highly recommended If the vertical mounting position is not possible care should be taken to avoid creating a low spot in the fan duct system where condensation might accumulate in the fan housing as shown in Fig 2 In situations where horizontal mounting is desired and condensation is likely to occur bathroom ventilation in cold climates this problem might be avoided by mounting the fan 30 degrees beyond horizontal as shown in Fig 3 Fig 1 Fig 3 2 0 Fan Sealing RB Series Fans are factory sealed no additional caulk or other materials are required to inhibit air leakage 3 0 Ducting Any type of ducting is acceptable however flexible nonmetallic ducting is recommended for easy installation and quieter operation Insulated flexible ducting is highly recommended in cold climates to prevent the warm bathroom air from forming condensation in the ducting where it is exposed to colder attic air The outlet of the fan should always be ducted to the outside Avoid venting the outlet of the fan di
3. Inline Fans fora Healthier Environment RB Series Installation Instructions Spruce Environmental Technologies Inc 3 Saber Way Ward Hill MA 01835 WWWw spruce com P N INO18 REV M 10 13 Spruce Please Read And Save These Instructions WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction d Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e When cutting or drilling into wall or ceiling do not damage electrical wiring and other
4. Mounting bracket included Recommended Ducting 4 6 8 or 10 Rigid or Flexible Ducting A Size Chart Fan A B a j Duct Weight L 2 Model Dim Dim Dim Size L 2 Estimated Equivalent Length of Rigid Metal Ducting resulting in 2in WC pressure loss for Duct Size listed Longer Equivalent Lengths can be accommodated at Flows Lower than that at 2in WC pressure loss see CFM Vs Static Pressure WC Table Do not operate fan above 80 of maximum Storage Temperature Range 32 100 degrees F Normal Operating Temperature Range 20 120 degrees F Maximum Inlet Air Temperature 140 degrees F continuous Continuous Duty 3000 RPM Thermally Protected Class F Insulation Rated for Indoor use only Rated for Residential and Commercial use Suitable for use with solid state speed controls Suitable for use over tub or shower Page 6 of 8 ALL RB SERIES FANS EXCEPT RB350 ARE ENERGY STAR RATED ENERGY STAR TERE TESTED CERTIFIED Conform to 7 h UL STD 507 US Cert toCANCSA 283 LISTED STD C22 2 No 113 HOME VENTILATING INSTITUTE AK JJ W p Mi l 77728 IN018 Rev M S 1DuuI 2 JOPjOD u p pu uuruuo59 I8uo ns asp si duupq 1Jpipy5pg JOID 8 OUD JONG IBQUUIDG UDIJDYAOD8S IDI IAN axnieg S O USA USA Duooss JOUOHAD JOJ JO A POOH USA JO ADD JUSA JOO2J S D 1 p o32 u p pu uuuio5 3 Ajguo ns s Sun ng p 1pinsuj PONG SIqX ld pepnjoul Jeyooig Buiuno
5. arate instructions for RB400 amp RB500 are included with Mounting Bracket Kit Insert Grommets into slots in mounting bracket Orientate the Electrical Box relative to Mounting Bracket as required Alach the fan to the mounting bracket with 3 10 self tapping screws provided Avoid over tightening screws Step 2 Select location for fan mounting A location 2 3 along the ducting Fig 5 a minimum of 10 feet away from the inlet vent to the fan or the Y T of a multi intake system will provide the quietest operation Fan should be mounted vertically to prevent moisture from accumulating in the fan housing Alach bracket to mounting structure with the 1 1 4 screws provided Fig 5 Step 3 Connect ductwork between fan inlet and area to be vented through inlet grille Fig 6 Flexible nonmetallic ducting is recommended for quietest operation and easiest installation Insulated flexible ducting is highly recommended for bathroom ventilation in all cold climate installations Metal worm drive clamps spring clamps adjustable plastic ratchets are recommended for connection of ducting Duct Tape should be used to retain insulation Fig 6 Step 4 Connect inlet grille s Fig 7 An optional back draft damper may be installed in the inlet grille to prevent cold air from backing into the inlet prevent conditioned air from escaping and also prevent condensation from forming inside the ductwork Backdraft dampers are highly recommende
6. d at each intake grille for bathroom ventilation in all cold climate installations Fig 7 Step 5 Connect outlet of fan to outside vent Fig 8 The outside vent may go through the roof sidewall or soffit as desired Flexible nonmetallic ducting is recommended for quietest operation and easiest installation Insulated flexible ducting is highly recommended for bathroom ventilation in all cold climate installations As the fan is typically outside of the building thermal boundary and is venting to the outside installation of insulation around the fan is not required Fig 8 Step 6 Make electrical connection to fan Fig 9 Insure any metal filing used in the installation is properly grounded A plastic cable connector such as a T amp B 3300 may be used to avoid any filing grounding problem Observe the proper wiring connections See Section 5 0 Note that the fan is not intended for connection to rigid metal conduit RB Series Wire AC Connection Fig 9 Page 5 of 8 IN018 Rev M RB SERIES PRODUCT SPECIFICATIONS The following chart shows fan performance for RB Series Commercial Residential Fans Typical CFM vs Static Pressure WC wo 68 2 230 270 300 450 500 176 211 247 353 420 138 170 210 281 344 2o 176 142 116 220 176 128 48 275 219 165 102 48 Power Consumption 120 VAC 60Hz 2 0 Amp Maximum Static Pressure per performance table Mounting
7. hidden utilities f Ducted fans must always be vented to the outdoors g If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit h NEVER place a switch where it can be reached from a tub or shower i Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer j Before servicing or cleaning unit switch power off at service panel and lock the service connecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel k Fan is suitable for use with solid state speed controls The recommended speed control if used is Pass amp Seymour Solid State Speed Control Cat No 94601 I i All wiring must be performed in accordance with the National Fire Protection Association s NFPA National Electrical Code Standard 70 current edition for all commercial and industrial work and state and local building codes All wiring must be performed by a qualified and licensed electrician All wiring must be in accordance with local and national electrical codes CAUTION For General Ventilating Use Only Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors RB Series Wiring Diagram 120 VA
8. ions Page 3 of 8 IN018 Rev M 4 0 Back Draft Dampers Back draft dampers allow airflow in only one direction preventing cold hot drafts from entering the vented area and minimize possible condensation and icing within the system while the fan is not operating Back draft dampers are highly recommended at each intake grille for bathroom ventilation in all cold climate installations Installation instructions are included with Spruce back dra0 dampers 5 0 Electrical Wiring All wiring must be performed in accordance with the National Fire Protection Association s NFPA National Electrical Code Standard 70 current edition for all commercial and industrial work and state and local building codes All wiring must be performed by a qualified and licensed electrician A Ground Fault Interrupter GFI circuit is not required in most installations check your local codes Ensure that all exterior electrical boxes are outdoor rated and properly sealed to prevent water penetration into the box A means such as a weep hole is recommended to drain the box Note that the fan is not intended for connection to rigid metal conduit 6 0 Applications Suitable for general ventilation bathroom venting fresh air supply duct boosting building pressurization etc Not suitable for kitchen range hood venting Page 4 of 8 IN018 Rev M Fig 4 7 0 Installation Step 1 Install Mounting Bracket as shown Fig 4 RB110 amp RB 275 Only sep
9. oof of purchase or a bill of sales for replacement Warranty claims made after the first thirty days after installation through the end of the Warranty Term Spruce will at its option either recondition or replace any Fan which fails due to defects in materials or workmanship The Fan must be returned at owner s cost to the Spruce factory This Warranty is contingent on installation of the Fan in accordance with the instructions provided This Warranty does not apply where any repairs or alterations have been made or alempted by others or if the unit has been abused or misused Warranty does not include damage in shipment unless the damage is due to the negligence of Spruce Spruce is not responsible for installation removal or delivery costs associated with this Warranty EXCEPT AS STATED ABOVE THE RB SERIES FANS ARE PROVIDED WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL SPRUCE BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR RELATING TO THE FAN OR THE PERFORMANCE THEREOF SPRUCE S AGGREGATE LIABILITY HEREUNDER SHALL NOT IN ANY EVENT EXCEED THE AMOUNT OF THE PURCHASE PRICE OF SAID PRODUCT THE SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE THE REPAIR OR REPLACEMENT OF THE PRODUCT TO THE EXTENT THE SAME DOES NOT MEET WITH SPRUCE S WARRANTY
10. rectly into an attic area The excess moisture from the bathroom can cause damage to building structure and any items stored in the attic Multiple venting points may be connected together using a T or Y fitting Ideally Duct should be arranged such that equal duct lengths are used between intake and T or Y fitting this will result in equal flow rates in each intake branch If adjustable intake grilles are used on multi intake systems then the opening on each grill should be equal in order to minimize noise and resistance Straight smooth runs of rigid metal ducting will present the least resistance and maximize system performance The Equivalent Length of Rigid Metal Ducting resulting in 2 WC pressure loss for each Fan Model is provided in the specification section of these Instructions Flexible ducting if used must always be as close to being fully extended as possible Formed rigid metal duct elbows will present the least resistance and maximize system performance recommended bend radius of elbow is at least 1 5 x duct diameter To ensure quiet operation of ENERGY STAR qualified in line and remote fans each fan shall be installed using sound attenuation techniques appropriate for the installation For bathroom and general ventilation applications at least 8 feet of insulated flexible duct shall be installed between the exhaust or supply grille s and the fan RB Series fans are not suitable for kitchen range hood remote ventilation applicat
11. yy See CCK amp _ wy L0Z8Z N d 00S82 90282 N d 00r83 19Z8Z N d OSE9N 88082 N d 00883 19Z N d ZZ9 8718 N d 01 183 SUD4 SOLIOS Jey uo ze e SU uey S 4 S gy JedIdAL Qos lt p lt POOH USA Fig 10 INO18 Rev M Page 7 of 8 IMPORTANT INSTRUCTIONS TO INSTALLER Inspect the RB Series Fan for shipping damage within 15 days of receipt Notify Spruce of any damages immediately Spruce is not responsible for damages incurred during shipping However for your benefit Spruce does insure shipments There are no user serviceable parts inside the fan Do not attempt to open Return unit to factory for service Install the RB Series Fan in accordance with all state and local building codes and state regulations WARRANTY Subject to any applicable consumer protection legislation Spruce Environmental Technologies Inc Spruce warrants that the RB Series Fan the Fan will be free from defects in materials and workmanship for a period of five 5 years from the date of manufacture the Warranty Term Warranty claims made during the first thirty days after installation Spruce will replace any Fan which fails due to defects in materials or workmanship The Fan may be returned at owner s cost to either the point of purchase or the Spruce factory The point of purchase may require pr