Home

American Standard 1730018.020 Installation Guide

image

Contents

1. COLONY CORNER 1730 SERIES rian Standard HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS WHIRLPOOL BATHING POOL INSTALLATION INSTRUCTIONS t 4 THANK YOU for selecting an American Standard bath Your new ea 1514mm bath is shipped to you after careful inspection The 59 5 8 whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximum performance and pleasure from gt this product please follow the instructions and PROVIDE ACCESS ow cautions FOR SERVICING PUMP amp CONTROLS 318mm 12 1 2 27 y ON OFF SWITCH 1168mm uea 6 JETS Oil OF DRAIN 2AIR List of Optional Components not included o 2134mm pa e Apron Kit 84 LEVELING TOP OF peer STRINGER i a symm DECKS enn fe see your American Standard Distributor wae 495mm List of Required Components not included 17 412 ME i e Drain 1583 470 58 Bath Filler zamm aaa POUGH f see your American Standard Distributor t BATH SUPPORT MATERIAL O D TAILPIECE FLOOR f List of Required Tools and Supplies NOTE If the optional apron PN 0730 121 is to be used with this tub the stringer height must be referenced from the finished floor Tools Supplies e Level Nails GENERAL SPECIFICATIONS FOR 1730 WHIRLPOOL e Tape Mea
2. NG WEIGHT TO THE RIM OR BOTTOM OF THE BATH ANY FINISH MATERIAL SUCH AS WALL BOARD OR TILE MUST BE SELF SUPPORTING IF IT CONTACTS THE DECK OF THE BATH TYPICAL CORNER INSTALLATION SUGGESTED INSTALLATION METHODS a CUTOUT LEVELING STRINGER LEVELING SURFACE WATERP ROOF SEALANT TILE WATERPROOF SEALANT LEVELING STRINGER BATH BATH SUNKEN OR ISLAND INSTALLATION RECESSED INSTALLATION RIGHT HAND DRAIN LEFT HAND DRAIN ACGESS PANEL ACCESS PANEL UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610 mm IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED NOTE If the optional apron PN 0730 121 is to be used with this tub the stringer height must be referenced from the finished floor 753451 100 Rev B 2 ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be insta
3. ains cigarette tar deposits or other surface blemishes e Abrasive cleaners or powders must not be used since they will dull the surface If the glossy surface looses its sheen dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax e Do not wax areas where you walk or stand e Do not allow nail polish remover acetone dry cleaning fluid paint remover or other solvents to come into contact with the surface Clean the surrounding surface immediately after using caustic drain cleaners e Burning cigarettes will damage the surface Should damage to the fixture occur repairs can be made quickly and easily Your distributor or builder can provide details 753451 100 Rev B 4 SPIC AND SPAN Is A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
4. lled on a 120 vac 15 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ELECTRICAL INSTALLATION SEPARATE 15 AMP GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 753451 100 Rev B 3 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations M otor for copper conductors only Always follow Hi Performance Taeng 120V Power Line local and national 1 1 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occurred during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a woode
5. n popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint FEATURES of YOUR NEW AMERICAN STANDARD ACRYLIC BATHTUB Your new acrylic bathtub has been molded in the newest plumbing fixture material available today Acrylics are tough durable finishes that are simple and easy to care for The colors have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and maintenance AFTERCARE and CLEANING e Always fill the tub with temperate water Excessively hot water may cause surface damage e Remove bath mat after use and hang to dry Allowing bath mat to dry in the tub may cause surface damage e Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES e Do not use wire brushes knives or sharp objects to remove st
6. osing materials are provided by others Check for availability of optional American Standard wall tiling bead required for recess installations Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping harness at any time FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS American Standard Inc 2005 753451 100 Rev B All product names listed herein are trademarks of American Standard Inc unless otherwise noted FRAMING AND INSTALLATION THE VARIETY OF INSTALLATIONS POSSIBLE FOR THIS BATH MAY REQUIRE FRAMING PROCEDURES OTHER THAN THOSE SHOWN LOCATE STUDS AS REQUIRED INSURE ROUGH DIMENSIONS ARE PROPER PLUMB AND SQUARE FOR WHIRLPOOLS PROVISION MUST BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED THIS BATH MUST BE SUPPORTED ALONG IT S ENTIRE BOTTOM WE RECOMMEND THE USE OF MORTAR AS A BEDDING MATERIAL SAND IS NOT RECOMMENDED APPLY ENOUGH BEDDING TO SUPPORT THE COMPLETE BOTTOM OF THE BATH AFTER THE BEDDING HAS BEEN POURED AND BEFORE IT SETS POSITION WHIRLPOOL OR BATH WITHIN INSTALLATION UNTIL THE RIM IS LEVELED AGAINST THE LEVELING STRINGERS SEE TYPICAL CORNER INSTALLATION SHOWN BELOW THE RIM OF THE BATH MUST NOT SUPPORT WEIGHT ALLOW THE BEDDING MATERIAL TO COMPLETELY HARDEN BEFORE APPLYI
7. sure e Putty INSTALLED SIZE 60 x 60 x 19 1 2 In 1524 x 1524 x 495mm e i e i WEIGHT 115 Lbs 52 Kg 3 alae sired y on E WEIGHT w WATER 908 Lbs 412 Kg ip J oint lers X35 Or 2 X GAL TO OVERFLOW 95 Gal 360 L e Screw Driver Stringers WHIRLPOOL MIN OPERATING VOL _______ 65 Gal 246 L BATHING WELL AT SUMP_____ _30 x 50 In 762 x 1270mm Standard 5 Drop Cloth BATHING WELL AT RIM 45 1 2 x 63 1 2 In 1156 x 1613mm W oodworking Tools 15 amp GFCI FLOOR LOADING 36 Lbs Sq FE 177 Kos Sq m Per epnal anrely at PROJECTED AREA Equipment e Cement Plaster PTS 27 8 e Caulking Gun Grout CUBE FT 54 WHIRLPOOL ELECTRICAL SPECIFICATIONS SYSTEM PUMP ________ 1 4 HP 9 9 AMPS 120V GENERAL INSTALLATION INFORM ATION Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit and check for leaks If a whirlpool do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and encl