Home

American Standard 2425L.202.020 Installation Guide

image

Contents

1. SPECIFICATIONS L w of SIDE VIEW END VIEW DRAIN OVERFLOW I B GENERAL SPECIFICATIONS FOR EVERCLEAN EVOLUTION WHIRLPOOLS AND BATH TUBS Description Dimensions Drain Height to Cut Out Rough In Tub Edgeto Weight with Product Apron Heater Ready Gallon to Whirlpool L W H Overflow Underside Pier Recess Centerline Water Floor Weight Mounting for Field Overflow Operating of Deck C GxF ExD Overflow J Loading Installation Volume 6060L V 1 1949 76 3 4 A 18 19 1 2 Template Template 824 Ib 374 kg Included 86 gal Corner W 1661mm 65 3 8 457mm 495mm Provided 751627 400 25 Ib sq ft 325 1 H 546mm 21 1 2 13 3 4 117 kg sq m 349mm 2422L M 1 1524mm 60 20 1 8 C20 58 1 2 60 3 16 690 Ib 313 kg Optional 74 gal 5 x 32 W 813mm 32 511mm 508mm 1485mm 1528mm 53 Ib sq ft 280 1 H 546mm 21 1 2 B 11 x 30 1 2 x 30 1 2 260 kg sq m 279mm 774mm 774mm 27711 L 1524mm 60 A 20 1 8 C 20 58 1 2 60 3 16 800 Ib 363 kg Optional 87 gal 5 x 36 W 914mm 36 511 508mm 1485mm 1528mm 53 Ib sq ft 329 1 H 546mm 21 1 2 x 34 1 2 x 34 1 2 260 kg sq m 279mm 876mm 876mm 7236L V 1 1829 72 20 1 8 C 20 70 1 2 72 3 16 1031 Ib 467 kg 11
2. rca Page 13 CG FMM ee Page 14 15 Drain Connection and System Page 16 Care and GS AUN TT TN Page 16 WV CURE pru m 17 753737 100 Rev 2 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS A WARNING Risk of personal injury Do not permit children to use this unit without adult supervision A WARNING Risk of personal injury Do not operate this unit without the guard over the suction fitting WARNING Risk of electric shock Do not permit electrical appliances hair dryer telephone radio etc within 60 inches 1524mm of this unit WARNING Risk of hyperthermia and possible drowning People using medications and or having adverse medical history should consult a physician before using this product WARNING Risk of personal injury Do not overfill unit before entering Entering tub when filled more than 2 3 can cause overflow and slippery conditions Exercise caution when entering and exiting WARNING No Food or Alcoholic Beverages Use of your bathtub immediately after meals is not recommended Avoid alcohol consumption before or during bathing Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning Pp Ppp WARNING Pregnanc
3. PROVIDE e 6 o9 T ACCESS TO WU 229 PUMP FOR SERVICING i ON ALL Lj INSTALLATIONS X CUTOUT IN FLOOR PUME can FOR DRAIN mm Re Y 2 44 2 AIR VALVES COT t mm 8 JETS 5 x 32 MODEL 2732L C L OF DRAIN OUTLET Note Deck Mounted fitting are not recommended 60 gt 1524mm 12 305mm f 1 16 1 2 za 419mm DIMENSIONS OF FIXTURES ARE NOMINAL 9 AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS 7124 1 AND 112 19 7 IN 29mm y HE CUT OUT IN 32 3 4 i J FOR DRAIN 832mm PROVIDE ACCESS TO PUMP FOR SERVICING Y ON ALL INSTALLATIONS 5 7 8 1 149mm a 8 1 2 216mm C L OF DRAIN OUTLET 753737 100 Rev H INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown Locate studs as needed Ensure roughing in dimensions are proper plumb and square Provisions must be made in all installations for an access opening for servicing the pump and controls It is strongly recommended that an additional opening be provided for access to the drain components The apron should not be used as the primary access opening 1 Position the whirlpool into the installation opening and level the deck in both directions shimming the integral support feet IF necessary Mark the final position of the underside of the deck by tracing a line on
4. OPERATING THE SYSTEM WITHOUT WATER DRY RUNNING WILL CAUSE PUMP DAMAGE AND VOID THE WARRANTY Always fill the whirlpool before operating the pump The air switch is mounted either on the deck or side wall of the tub 1 Fill the Whirlpool Water level must be at least one inch 25mm above the highest jet for proper operation See diagram below Do not fill whirlpool more than 2 3 full prior to the user completely immersing themselves into unit 2 Start Whirlpool Push on center of button Button will depress and whirlpool will start 3 Stop Whirlpool Depress and release button and whirlpool will stop SAFE T HEATER REMOVABLE BLANK AIR TUBING AIR ACTUATOR SWITCH location varies with model WATER LEVEL ul OUTLET MUST BE X GFCI PROTECTED all heaters require separate GFCI 6060L V includes factory installed heater 4 Air Volume Control Adjustments Water turbulence is determined by the amount of air mixed with the water Rotate the air volume control counterclockwise for more turbulence clockwise for less Air Volume Control Adjustments MORE AIR LESS AIR 753737 100 Rev H 14 Adjustable Flow Clean Jet The water flow action may be adjusted from vigorous to soft by rotating the nozzle clockwise for vigorous massage and counter clockwise for soft massage NOTE You may balance the air volume control and nozzle adjustment for the most desirable conditio
5. Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line Replace the bath deck and secure it into place Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal Remove excess sealant per the manufacturer s instructions Finished bath deck surface material must be self supporting and secured per local codes Waterproof Sealant P Bath deck support material Bathtub support structure per installation instructions provided with the tub 753737 100 Rev H WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes A WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Permit access for servicing motor as noted 4 All building materials and wiring should be routed away from the pump body and heater if equipped PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS GFCI CIRCUIT REQUIREMENTS FOR MODEL NU
6. electrical shock Turn off the power and do not use the bath until the source of the problem has been identified and corrected 1 Route two separate branch circuits to the junction box near the whirlpool as shown in Figure 2 Each branch circuit MUST BE PROTECTED and must use copper conductors only 2 Ensure the heater and pump are properly GROUNDED and BONDED as required Attach the 8 AWG solid copper conductor supplied with the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3 The conductor is secured to the lugs using set screws The motor frame shall have a second 8 AWG solid copper conductor connected from the frame bonding lug to the homes electrical panel or approved local bonding point as shown in Figure 3 Fig 3 SEPARATE Fig 2 JS AMP GEGLOUTEET ELECTRICAL INSTALLATION 120 VAC HEATER S PUMP MOTOR HEATER RUN 8 AWG SOLID COPPER CONDUCTORS FROM HEATER BONDING LUG TO PUMP MOTOR FRAME LUG AND FROM PUMP MOTOR LUG TO APPROVED GROUND AS SHOWN SEPARATE 15 AMP GFCI OUTLET SEPARATE 20 AMP GFCI OUTLET for 2 1 H P R PUMP ONLY 120 VAC FIRST COPPER CONDUCTOR SECOND COPPER CONDUCTOR PUMP MOTOR FRAME WITH Ca BONDING LUGS TO GROUND ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 13 753737 100 Rev H OPERATION NOTE Each whirlpool is shipped from the factory with an air actuator on off switch and pump with attached power supply cord
7. paint remover or other solvents to come into contact with the surface e Clean the surrounding surface immediately after using caustic drain cleaners e Burning cigarettes will damage the surface Should damage to the fixture occur repairs can be made quickly and easily Your distributor or builder can provide details Do not permit drain cleaner to enter the circulation system CIRCULATION SYSTEM CLEANING PURGING PROCEDURES STEP 1 Once every month purge and clean the circulating system Fill whirlpool with warm water and add two teaspoons of dishwasher detergent and one half cup of house hold bleach STEP 2 Activate whirlpool system in accordance with operating instructions or two minutes STEP 3 Drain and refill whirlpool with cool water and circulate for additional five minutes STEP 4 Drain whirlpool completely 753737 100 Rev H 16 AS AMERICA INC AMERICAN STANDARD LIMITED LIFETIME WARRANTY FOR EVERCLEAN EVOLUTION ACRYLIC WHIRLPOOLS AS America American Standard warrants to the original consumer purchaser that it will at its option repair or replace this whirlpool or any of its parts that are found by American Standard in its sole judgment to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY MANNER CONTRARY TO THE INSTALLATION INSTRUCTIONS In no event wi
8. self supporting if it contacts the deck of the bath For Models 2645L V 2771L V 2773L V 2774L V 2775L V 2422L V 2711L V 2908L V 6060L V and 7236L V Replace whirlpool and re shim the integral support feet shimming the entire length of the support feet Secure the shims using construction adhesive silicone mortar or equivalent materials While not a necessity the use of a foundation base consisting of ES cement mortar or grout will help provide a solid and secure installation The of the bath must not support weight If foundation base is used allow the NOTE Tile bead kit not included and bedding material to completely harden before applying weight to the rim or bottom of must be purchased separately the bath Any finish material such as tile or wall board must be self supporting if it contacts the deck of the bath TYPICAL RECESS INSTALLATION TYPICAL PIER TYPE INSTALLATION AS DESIRED MOUNTING LEVELING SURFACE FRONT EDGE SIBINGEHS WATERPROOF OF BATH MUST lt gt BE SUPPORTED C BY STUD WALL OR AMERICAN STANDARD ACCESS PANEL MUST BE LOCATED APRON KIT ON THE SAME SIDE AS THE MOTOR ACCESS PANEL MUST BE LOCATED ALLOW OPEN FRAMING ON ON THE SAME SIDE AS THE MOTOR PUMP MOTOR END FOR SERVICE ALLOW OPEN FRAMING ON PUMP MOTOR ACCESS PANELS NOT REQUIRED END FOR SERVICE FOR BATH TUBS ACCESS PANELS NOT REQUIRED UNLESS AN ACCESS OPENING OF AT LEAST
9. to the studs see Figure 1 2 Remove the whirlpool and attach a 1 x 4 stringer to the studs with the top of the stringer touching the traced line A The rim of the bath must not support weight FIGURE 1 3 Install drain components to the whirlpool following the drain installation instructions Before TYPICAL INSTALLATION replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing and Table 1 for suggested opening size shadowed and location dimensions The drain overflow of the bath extends below the bottom of the bath Note that this requires a cutout in the floor A The floor structure beneath the bath must be able to support a total weight of bath water and bather Refer to Table 1 under total weight for your model For Models 2425L V LHO and 2425L V RHO 2732L This bath must be supported along its entire bottom Use mortar as bedding material do not use sand or foam Apply enough mortar to support the complete bottom of the bath After the mortar has been poured and before it sets position whirlpool or bath within recess until the rim is leveled against the leveling stringers see Typical Recess Installation shown below A The rim of the bath must not support weight Allow the mortar material to completely harden before applying weight to the rim or bottom of the bath Any finish material such as tile or wall board must be
10. 1 gal 6 36 W 914mm 36 511mm 508mm 1790mm 1833mm 57 Ib sq ft 420 1 H 546mm 211 27 B11 x 34 1 2 x 34 1 2 280 kg sq m 279mm 876mm 876mm 24251 L 1524mm 60 19 1 8 20 1 4 60 3 16 675 Ib 306 kg p Optional 70 gal 5 x 32 W 813mm 32 485mm 515mm 1528mm 54 Ib sq ft i 265 1 LHO H 521mm 20 1 2 10 1 2 x 30 1 2 262 kg sq m RHO 266mm 774mm 2645L V L 1676mm 66 A 15 1 4 C 18 1 4 64 66 3 16 580 Ib 263 kg Optional 58 gal Oval W 914mm 36 387mm 464mm 1625mm 1681mm 36 Ib pies i 219 1 H 502mm 19 3 4 8 1 4 34 x 34 1 2 cuadrados 209mm 863mm 876mm 175 kg sq m 2908L L 1676mm 66 15 1 8 C 18 1 4 Template Template 659 Ib 299 kg Optional 68 gal Reminiscence W 914mm 36 384mm 464mm Provided 752540 400 40 Ib sq ft 257 1 H 616mm 24 1 4 13 191 kg sq m 330mm L 1829mm 72 A 17 3 8 C 19 1 2 70 1 2 72 3 16 965 Ib 434 kg Optional 95 gal W 1219mm 48 441mm 495mm 1791mm 1833mm 40 Ib sq ft 360 1 H 546mm 21 1 2 12 x 46 1 2 x 46 1 2 195 kg sq m 305mm 1181mm 1181mm L 1829mm 72 17 18 1 4 70 1 2 72 3 16 751 Ib 341 kg Optional Optional 78 gal W 914mm 36 432mm 464mm 1791mm 1833mm 40 Ib sq ft 296 I H 502mm 19 3 4 12 x 34 1 4 x 34 1 2 190 kg sq m
11. 12 X 24 305 X 610mm FOR BATH TUBS IS Masi E UNLESS AN ACCESS OPENING OF AT LEAST 12 24 305 X 610mm IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED FOR E amp D DIMENSIONS SEE TABLE 1 ON PAGE 5 FOR G amp F DIMENSIONS SEE TABLE 1 ON PAGE 5 753737 100 Rev H 10 TYPICAL FLANGE MOUNTING DETAIL SUGGESTED WHIRLPOOL BATH INSTALLATION METHOD WATERPROOF DRYWALL OR CEMENT BOARD TILE 1 3 25 x 76mm WOOD STRINGER FULL LENGTH WATERPROOF DRYWALL OR CEMENT BOARD SEALANT 4 102mm DRYWALL SCREW 1 x 3 25 x 76mm WOOD STRINGER FULL LENGTH SECURE THE BATH TO THE STUDS AS SHOWN FOR WOOD OR STEEL STUD CONSTRUCTION UNDER DECK MOUNTING INSTRUCTIONS TYPICAL INSTALLATION CORNER PA WHIRLPOOL ACCESS PANEL SEE CUTOUT TEMPLATE PROVIDED UNLESS AN ACCESS OPENING OF AT LEAST 12 x 24 305 x 610mm IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED Please note that care must be taken to protect the surface of the tub during all aspects of the installation Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result Install the tub per the installation instructions provided with the unit Prepare the bath deck support structure per the local codes Note the bath deck must be self supporting Cut bath deck to your specifications Place the bath deck in position and trace the opening on the tub with a soft pencil
12. 305mm 870mm 876mm L 1829mm 72 16 1 4 18 1 4 70 1 2 72 3 16 821 Ib 372 kg Optional Optional 82 gal W 1067mm 42 413mm 464mm 1791mm 1833mm 42 Ib sq ft 310 1 H 502mm 19 3 4 B 12 x 40 1 2 x 40 1 2 203 kg sq m 305mm 1029mm 1029mm 2775L L 2159mm 85 16 1 2 C 18 1 4 Template Template 756 Ib 343 kg Optional 75 gal Cadet Corner W 1524mm 60 419mm 464mm Provided 752539 400 34 Ib sq ft 284 H 502mm 19 3 4 B 11 115 kg sq m 279mm L 1524mm 60 17 1 4 C 18 1 4 58 1 2 60 3 16 524 Ib 237 kg Optional Optional 55 gal W 832mm 32 3 4 438mm 464mm 1485mm 1529mm 43 Ib sq ft 208 1 H 502mm 19 3 4 B 8 1 2 x 31 1 4 x 31 1 4 213 kg sq m 216mm 794mm 794mm TABLE 1 5 753737 100 Rev H ROUGHING IN REFERENCES 5 x 32 MODEL 2422L V lt 60 1524mm A 32 813mm CUT OUT IN FLOOR 1 FOR DRAIN 7 3 4 J 197mm B N PROV
13. DEL 2711L 70 1829 36 1 2 102mm OF DRAIN OUTLET C L OF DRAIN OUTLET 9 x 14 FLOOR CUTOUT PUMP REMINISCENCE MODEL 2908L 66 ja 1676mm a a 330mm 1 36 914 9 x 12 18 FLOOR CUTOUT pu 229mm x 305mm 2 1 2 REF 64mm Y PROVIDE ACCESS 229mm S EE DRAIN PUMP FOR SERVICE ON ALL INSTALLATIONS 753737 100 Rev H 229mm x 356mm PROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124 1 AND A112 19 7 ROUGHING IN REFERENCES CADET 6 x 42 MODEL 2774L 72 128 1829 305mm FINISHED WALL E aL PROVIDE ACCESS 229mm ae INSTALLATIONS pare rere 1067mm CUTOUT IN FLOOR 21 FOR DRAIN 533mm Y 2 1 4 2 VALVES lt 8 JETS OF DRAIN OUTLET CADET 6 x 36 MODEL 2773L 9 72 gt ar 127 1829mm 229mm 305 3 4 19mm gt FINISHED f WALL 35 3 4 m
14. E THESE INSTRUCTIONS 3 753737 100 Rev H General Installation Information Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage Before installation and before enclosing with wallboard tile etc the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling Do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others For electrical requirements refer to section titled Whirlpool Electrical Installation Instructions Check for availability of optional American Standard wall tiling bead required for recess installation Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth A WARNING Do not lift whirlpool by the piping harness at any time List of Required Tools and Supplies Tools Level Tape Measure Pipe Wrench Slip Joint Pliers Screw Driver Personal Safety Equipment Caulking Gun Standard Woodwork
15. ESS TO 3 76 SERVICING C L OF BAAN 8 1 4 INSTALLATIONS 210mm 5 x 32 IA RHO MODEL 2425L V RHO shown 5 x 32 IA LHO MODEL 2425L V LHO si 924mm OF DRAIN L 10 1 2 e OUTLET 267mm TI 1 2 7 8 76mm 191mm 73mm 1 16 406mm All PUMP 229mm fi 1 _ OUT IN FLOOR m eism SE 0 lt Y CORNER MODEL 6060L V i Geena a 76 3 4 ACCESS OPENING FOR MODELS 343mm lt 1949mm g REFER TO TYPICAL RECESS i NSTALLION DIAGRAM PAGE 10 65 3 8 1661mm PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS 27 17 3 4 J 451mm 3 222 178mm Y Y 5 5 8 9 229mm 19 3 4 349mm 143mm QUT OUT C L OF DRAIN OUTLET FOR DRAIN DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124 1 AND A112 19 7 7 753737 100 Rev H ROUGHING IN REFERENCES CADET CORNER MODEL 2775L A 1 4 S 42 1 2 3 lt lt 229 X 305mm eS 080mm GOTOUTIN ye FLOOR FOR DRAIN 42 3 8 1076mm A i N i 60 il Figen 1524mm 2 914 REF 70mm ES 2 T KH 9 2 PROVIDE ACCESS TO K SERVICING ONALL LIP VY INSTALLATIONS i PUMP Y Y i 11 42 1 2 C L 279mm 1080mm em L C L OF DRAIN OUTLET 2159mm ELLISSE 4 x 48 MO
16. IDE ACCESS TO 1 PUMP FOR SEM CUNT INSTALLATIONS OF DRAIN OUTLET P Gron gt 6 x 36 MODEL 7236L V 75i 1828mm S L OF DRAIN 11 OUTLET 279mm 3 14 gt 83mm 1 13 3 4 7 3 4 349mm ig 3 197mm PT 76mm rt 36 i 914 9 O fill 229 V PROVIDE 2 ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS 5 x 36 MODEL 2771L V m 1524mm gt OF DRAIN 11 OUTLET 279mm el Lg 31 4 83mm mns iM eS CUT OUT IN FLOOR FOR DRAIN 3 76mm LL 1 9 36 B 229mm Q 7 1 2 75 d 191mm 13 3 4 i of i 849mm mi mm A PROVIDE lt ACCESS TO PUMP FOR SERVICING ONALL INSTALLATIONS DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124 1 AND A112 19 7 753737 100 Rev H 6 ROUGHING IN REFERENCES OVAL MODEL 2645L 6 1676mm lt 11 1 4 286mm 1 3 4 44mm 18 _ j 457mm Be r jm DU tam 229mm Cramm NN CUT OUT IN FLOOR PX AG 9 FOR DRAIN 7 PROVIDE i ACC
17. MBERS The whirlpool should be installed on a 120 vac 15 amp dedicated GFCI circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A 2422 2425 2645 2732 2771 2908 grounded neutral wire and a third wire earth ground are essential ALL MODELS Optional heater requires a separate 15 amp maximum GFCI circuit The whirlpool should be installed on a 120 vac 20 amp dedicated GFCI circuit 6060 2775 2773 2711 The circuit should be hard wired from the electrical power supply panel The 2774 7236 circuit must be a three 3 wire circuit from the electrical supply panel A ALL MODELS grounded neutral wire and a third wire earth ground are essential Optional heater requires a separate 15 amp maximum GFCI circuit 120 VAC WHITE ELECTRICAL DIAGRAM m READ AND FOLLOW ALL INSTRUCTIONS WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations only Always follow 115V Power Line local and national wieste awaj E 753737 100 Rev 12 6060L V Corner Only OPERATION Fig 1 WARNING Prior to operation review the Important Safety Instructions listed at the beginning of this instruction manual Once the heater is installed and the whirlpool pump is operating the heater is A totally automatic The heater w
18. THOSE OF MERCHANTABILITY OR FITNESS FOR AN INTENDED PURPOSE Some jurisdictions do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these limitations and exclusions may not apply to you 7 Responsibility for compliance with local code requirements Since local code requirements vary greatly distributors retailers dealers installation contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a specific product This warranty gives you specific legal rights You may have other legal rights that vary from state to state For service under this warranty you should contact the following By Mail American Standard Inc By Telephone P O Box 6820 1 800 442 1902 Piscataway N J 08855 Attention Customer Care Center AS AMERICA INC AMERICAN STANDARD ONE YEAR LIMITED WARRANTY FOR E Z INSTALL WHIRLPOOL HEATER If inspection of this AS American Inc American Standard plumbing product within one year after its initial purchase confirms that it is defective in materials or workmanship American Standard will repair or at its option exchange the product for a similar model This warranty applies only to the original purchaser and installation of these products This limited warranty does not apply to local building code compliance Since local building codes vary considerably
19. ill help maintain the temperature of the water in VMETTCAM the bath E Z INSTALL Pressure Switch HEATER ON LIGHT gt FACTORY INSTALLED NOT FOR RESALE The heater is equipped with a preset pressure switch The pump must be HEATER P N 753174 100 QD mme running with water flowing in the whirlpool to allow the heater to turn on Indicator Light This light turns on whenever the heater is operating High Limit Switch The heater includes an exclusive Intelligent High Limit This safety circuit will not false trip from hot tap water It will only turn the heater off if the thermostat fails If the high limit trips frequently call a service technician To manually reset the circuit in the event that the High Limit switch has been activated simply 1 Turn off the whirlpool pump 2 Drain water from the tub 3 Remove power from heater by unplugging at receptacle or turning off circuit breaker 4 The heater circuit will automatically reset in less than 15 minutes 5 Restore power to the heater 6 Whirlpool bath is now ready to use ELECTRICAL CONNECTIONS Install a separate 120VAC 15AMP dedicated circuit with GFCI Ground Fault Circuit Interrupter protection At initial start up with power ON push the GFCI test button The reset button should pop out Push this button in to reset If the fails to operate in this manner there is a ground fault or malfunction indicating the possibility of
20. ing Tools Supplies Nails Putty Caulking waterproof 1 x 4 Stringers Drop Cloth Cement Plaster Grout LIST OF OPTIONAL COMPONENTS NOT INCLUDED Description EverClean Evolution Corner Model Number Required Components Not Included Drain Drain White Specify Finish 1599 500 020 1583 470 Optional Components Not Included E Z Tile Install Apron Bead Heater Kit Kit NOT INCLUDED AVAILABLE EverClean Evolution 5 x 32 1599 500 020 1599 205 XXX 9261 019 EverClean Evolution 5 x 36 1599 500 020 1599 205 XXX 9261 019 eje EverClean Evolution 6 x 36 7236 1599 500 020 1599 205 XXX 9271 019 J EverClean Evolution 5 x 32 IA 1599 500 020 1599 205 XXX INTEGRAL EverClean Evolution Oval 1599 500 020 1583 470 XXX 9266 018 EverClean Reminiscence 1599 500 020 1583 470 XXX NOT AVAILABLE EverClean Ellisse 1599 500 020 1583 470 XXX NOT AVAILABLE EverClean Cadet 6 x 36 1599 500 020 1583 470 XXX 9272 018 EverClean Cadet 6 x 42 1599 500 020 1583 470 XXX 9272 018 EverClean Cadet Corner 1599 500 020 1583 470 XXX NOT AVAILABLE EverClean 5 x 32 1599 500 020 1583 470 XXX For these components please see your Vendor These models require American Standard Lifetime Drain 1599 205 or 1599 500 753737 100 Rev H
21. ll American Standard be liable for the cost of repair or replacement of any installation materials including but not limited to tiles marble etc This limited warranty DOES NOT COVER the following 1 Defects or damages arising from shipping installation alterations accidents abuse misuse lack of proper maintenance and cleaning as directed in the owner s manual and use of other than genuine American Standard replacement parts in all cases whether caused by a plumbing contractor service company the owner or any other person 2 Deterioration through normal wear and tear and the expense of normal maintenance 3 Commercial application 4 Options and accessories American Standard s limited warranty on these items is one year for parts only and excludes labor This one year limited warranty covers accessories manufactured by American Standard e g aprons drains grab bars heaters trim kits against defects of material or workmanship Warranty coverage begins on the date the accessory was originally purchased by the owner 5 Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor or other costs incurred in connection with product removal or installation under this limited warranty 6 ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES INCLUDING
22. n Large Jet Small Jet Com Softer Massage Softer Massage counter clockwise counter clockwise More Vigorous Massage More Vigorous Massage clockwise clockwise Lifetime Drain Model 1599 required on Models 7236L V 2422L V 2425L V 2771L V Overflow Partially fill tub then enter tub before completely filling to prevent overflow Toe Tap Drain Depress drain cap to open or close drain Access Panel Model 2425L V Remove access panel to service motor Toe Tap Drain Access Panel Overflow Model 2425L V only 15 753737 100 Rev H DRAIN CONNECTION AND SYSTEM TEST Using recommended drain assembly connect whirlpool drain to waste line in accordance with the drain assembly instructions Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occurred during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or a
23. ny other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint AFTERCARE and CLEANING e The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and maintenance e Always fill the tub with temperate water Excessively hot water may cause surface damage e Remove bath mat after use and hang to dry Allowing bath mat to dry in the tub may cause surface damage e Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES e Do not use wire brushes knives or sharp objects to remove stains cigarette tar deposits or other surface blemishes e Abrasive cleaners or powders must not be used since they will dull the surface If the glossy surface looses its sheen dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax Do not wax areas where you walk or stand e Do not allow nail polish remover acetone dry cleaning fluid
24. sent to By Mail American Standard Inc By Telephone P O Box 6820 1 800 442 1902 Piscataway N J 08855 Attention Customer Care Center SERVICE For service or repair contact the number below The model number and serial number for your whirlpool are located on a label near the motor HOTLINE FOR HELP For toll free information and answers to your questions call 1 800 442 1902 weekdays 8 00 a m to 5 00 p m Eastern Time Product names listed herein are trademarks of AS America Inc AS America Inc 2008 17 753737 100 Rev H
25. the purchaser of this product should check with a local building or plumbing contractor to ensure local code compliance before installation This warranty shall be void if the product has been moved from its initial place of installation if it has been subjected to faulty maintenance abuse misuse accident or other damages if it was not installed in accordance with American Standard s instructions or if it has been modified in a manner inconsistent with the product as shipped by American Standard American Standard s option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation nor shall American Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this warranty Some states or provinces do not allow the exclusion or limitation of implied warranties so this exclusion may not apply to you This warranty gives you specific legal rights You may have other statutory rights that vary from state to state or from province to province in which case this warranty does not affect such statutory rights For service under these warranties it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased or that a service request including a description of the product model and of the defect be
26. y If you are or think you may be pregnant consult your physician before using the bathtub Never drop or insert any object into any opening Use this unit only for its intended use as described in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the bathtub without the test button being pushed a ground current is flowing indicating the possibility of an electric shock Do not use this hydromassage bathtub Disconnect the hydromassage bathtub and have the problem corrected by a licensed electrician before using A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no 8 AWG solid copper bonding conductor between this unit and all other electrical equipment and exposed metal in the vicinity as needed to comply with local requirements To reduce the risk of an electric shock connect this connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this unit SAV
27. y o INSTALLATION amp OPERATION GUIDE FOR EVERCLEAN EVOLUTION WHIRLPOOLS AND BATHTUBS MODEL 2422L V 5 x 32 MODEL 6060L V CORNER MODEL 2771L V 5 x 36 MODEL 26451 V OVAL MODEL 7236L V 6 x 36 MODEL 2425L V LHO 5 x 32 IA LHO MODEL 2425L V RHO 5 x 32 IA RHO MODEL 2908L REMINISCENCE MODEL 2711L ELLISSE MODEL 2773L CADET 6 x 36 MODEL 2774L CADET 6 x 42 MODEL 2775L CADET CORNER MODEL 2732L 5 x 32 THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping All you need to finish the whirlpool installation are your selected fittings and electrical connections To ensure maximum performance and pleasure from this product please follow the instructions and cautions FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS AS Americas Inc 2013 All product names listed herein are trademarks of AS America Inc unless otherwise noted 1 753737 100 Rev H TABLE OF CONTENTS cp AQ ee E Page 3 General Informations Page 4 Optional Reo escena bdo Page 4 m T Page 5 Roughing in IHETEI ONCE ETT Page 6 9 Framing and Support Instructions Page 10 Mounting d asigRleiro y M Page 11 Ele tri al Connecti nS s 12 6060L V Corner EZ Install

Download Pdf Manuals