Home
Lithonia Lighting ISD BC 120/277 WH M10 Use and Care Manual
Contents
1. NOTE For long low voltage wiring runs or where excessive electrical noise exists shielded cable or conduit is recommended 5 Installation may now be completed by carefully positioning all wires to provide room in outlet box for dimmer Mount dimmer into box with mounting screws supplied Attach wallplate 6 Restore power at circuit breaker or fuse INSTALLATION IS COMPLETE COLOR CONVERSION PROCEDURE The color of this device can be changed to suit your interior design requirements Simply obtain a color conversion kit of the appropriate color from your Lithonia distributor and proceed as follows please note that wallplate must be removed 1 Select the color of the face you desire The frame has snaps on its sides Using your fingers grip around the frame and push on one side to release it from the strap refer to Figure 2 2 3 Take the new frame and position it properly to the strap Line up the plastic snaps with the square holes in the strap Insert the snaps on one side of the frame into the strap 4 Firmly press sideways and down to slip the other snaps into place The frame snaps in with a audible click Ensure that all four snaps are secure 5 Moving the slider up or down will automatically engage the slider control mechanism Replace wallplate The color conversion is complete TO OPERATE GREEN LED will remain ON when the lights are OFF Facilitates access to switch in the dark Depress push button switch to
2. White EP Driver e Neutral White Note The ISD BC can be connected to 4 LPCS remote Power Stations The Purple and Gray wires of the Class 2 circuit can be connected to a maximum of 50 ballasts Wiring Diagram 5 Two Location Control with LPCS Power Control Station 3 Way Switch Dimmer LPCS Cap off Black wire with Wire Connector Common Terminal Black Screw 120V 277V Purple Gray gt Additional Ballast Or Driver Hot Black e Black cb Blue Primary Side ned Black gt Line 120 277VAC 60Hz sO Green Green 0 10 VDC Ballast or LED Driver Ground Ground gt To Additional e Neutral White Ballast Or Driver DI 40X IP710 00A
3. PartNo vage ur oc ia ove amv RZT I32 P1x32T8 120 Dim5 B F17T8 RZT 2832 P1x32T8 120 Dim5 B FBO16T8 RZT 3832 P1x32T8 120 Dim5 B F25T8 RZT 132 P1x32T8 120 Dim5 B FBO24T8 120 45 N A RZT 2832 F32T8 P1x32T8 120 Dim5 B F32T8 120 3 N A 7 RZT 3832 F32T8 QTP1x32T8 120 Dim5 B FBO32T8 U 6 120 N A RZT 1TTS40 FT40W 2G11 P1x32T8 120 Dim5 B FBO31T8 U 120 P2x32T8 120 Dim5 B F32T8 120 N A 277 P2x32T8 120 Dim5 B FBOS2T8 U 6 120 N A VZT 132 P2x32T8 120 5 OS1T8 U VDC 2832 TP P3x32T8 120 Dim5 Q F32T8 VZT 2832 QTP3x32T8 120 Dim5 Q 2 8 0 6 127 3532 P3x32T8 120 Dim5 Q FBOSIT8 U VZT4S32 QTP4x32T8 120 Dim10 B F32T8 27 132 QTP4x32T8 120 Dim10 B FBOS2T8 U 6 VDC 2832 TP QTP4x32T8 120 Dim10 B 3178 0 m VZT3532 2 8 277 1 32 8 277 Dim5 B 17 8 VZTAS32 F32T8 277 P1x3278 277 Dim5 B FBO16T8 1 3278 277 Dim5 B 25 8 FM26W GX24Q 120 277 P1x32T8 277 Dim5 B 24 8 FM26W GX24Q 120 277 P1x32T8 277 Dim5 B F32T8 FM26W GX24Q 120 277 1 3278 277 Dim5 B FBOS2T8 U 6 FM26W GX24Q 120 277 P1x32T8 277 Dim5 B 0311 FM26W GX24Q 120 277 P2x32T8 277 Dim5 B F327 FM26W GX24Q 120 277 P2x32T8 277 Dim5 B FM26W GX24Q 120 277 P2x32T8 277 Dim5 B ZT 2026 M2 LD 277 FM26W GX24Q 120 277 P3x32T8 277 Dim5 Q IZT 1T42 M2 BS 120 FM32W GX24Q 120 277 P3x32T8 277 Dim5 Q izrrraewoesezrr crwsewiexeso 9 Dina i LD 120 CFM32W GX24Q 120 277 30 QTP4x3278 277Dim10 B 2 8 126277 CF
4. Hot Black 3 Way Dimmer 0 10 VDC Line 120 277VAC 60Hz Ground Ballast or LED Driver Yellow White Primary Side Neutral White Wiring Diagram 3 Three Location Control Application Common Terminal Black Screw 3 Way Switch Hot Black 4 Way Switch Dimmer To gt Additional gt Ballast Or Driver Line 120 277VAC 60Hz Ground Ground 0 10 VDC Ballast or LED Driver Green Ground White Primary Side e Neutral White Travelers between switches IN Travelers between switches OUT Wiring Diagram 4 Single Control with Multiple LPCS Power Control Station Application LPCS 120V 277V Dimmer Cap off Black wire with Wire Connector Purple Hot Black To circuit 2 LPCS 120V 277V Cap off Black wire with Wire Connector Purple To Cap off Black wire with Wire Connector Gray gt Gray x Additional Red Red pot Black a Black Line Black 120 277VAC 60Hz Green Ground o gt To Additional Ballast Or Driver SD Primary Side 0 10 VDC Ballast or LED Driver Red bi Ballast Red e Or Driver Black D Blue Primary Side Black ee 0 10 VDC Ballast or
5. INSTALLATION INSTRUCTIONS WARNING TO BE INSTALLED AND OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS LIGHTING CONTROLS o s Synergy AnAcuityBrands Company Designer Wall Box Dimmer Single Pole One location or 3 Way Multi location Fluorescent or LED Cat No ISD BC Lighted Rated 1200VA 120VAC 60Hz 1500VA 277VAC 60Hz For use with 0 10 dimming ballasts or LED drivers INSTALLATION INSTRUCTIONS Synergy f LIGHTING CONTROLS 1335 Industrial Boulevard Conyers GA 30012 Phone 800 533 2719 www synergylightingcontrols com GUARANTEE Synergy Lighting Controls warrants all equipment to be free from defects in manufacturing under normal and proper storage installation and use for a period of two years Our guarantee liability extends only to the repair or replacement of the defective part and no labor charges for correction of the defect by repair or replacement will be honored by Synergy Lighting Controls unless prior written authority has been granted by our Customer Service Department For Technical Assistance Call 1 800 533 2719 www synergylightingcontrols com o s Synergy LIGHTING CONTROLS DI 40X IP710 00A AnsSAcuityBrands Company Figure 1 Dimmer Functions Slider Mounting Strap Side Sections ON OFF Push Button Switch WARNING IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTION
6. M32W GX24Q QTP4x3278 277 Dim10 B FBO32T8 U 6 IZT 2T42 M3 BS 120 CFM32W GX24Q 120 277 15 Dim10 B 11 127 2742 3 85 0277 CFM32W GX240 120 277 C C IZT 1T42 M2 BS 120 IZT 1T42 M2 BS 277 ZT 1T42 M2 LD 120 ZT 1T42 M2 LD 277 ZT 2Q26 M2 BS 120 ZT 2Q26 M2 BS 277 ZT 2Q26 M2 LD 120 C C C C C C C C C C 2142 M3 LD 120 FM32W GX24Q 120 277 Dim FP54T5HO 2742 M3 LD 277 FM32W GX24Q 120 277 na 2 Dim FP54T5HO IZT 1T42 M2 B5 120 CFM42W GX24Q 120 277 23 i 1742 M2 LD 120 FM42W GX24Q 120 277 23 C 1T42 M2 LD 277 CFM42W GX24Q 120 277 N A IZT 2T42 M3 BS 120 CFM42W GX24Q 120 277 1 C 2 T 2742 M3 LD 120 CFM42W GX24Q 2742 M3 LD 277 FM42W GX24Q 120 277 15 IZT 1T42 M2 BS 120 CFQ26W G24Q 120 277 2x54 277PHO Di FT55DL 11x54 277PHO Di 55 2 54 277 55 1 54 120 T2x54 120 Q Q Wiring Diagram 1 Single Control Application Cap with Dimmer Wire Connector Hot Black o _ 0 10 VDC Ballast or Line LED Driver 120 277VAC 60Hz White Primary Side Neutral White Wiring Diagram 2 Two Location Control Application Common Terminal Black Screw 3 Way Switch
7. ON position Lights will turn ON GREEN LED will turn OFF Move slider control lever lights will brighten or dim to level set Depress push button switch to OFF position Lights will turn OFF GREEN LED will turn ON Lights will turn ON at set brightness level from either switch location in a 3 way installation TROUBLESHOOTING Lights do not go to full output Move the slider to the top and adjust the high end trim until the desired output is achieved Lights do not dim low enough Disconnect the 0 10V control circuit from the purple and gray dimmer leads Short the 0 10V control leads from the ballast s together and verify minimum dimming level If the lamps are not dim enough in this configuration check the dimming specs and or operation of the ballast If the verified minimum level is acceptable but not achieved when the dimmer is connected replace the wall box dimmer or contact Lithonia Control Techinical Service Department at 800 533 2719 Figure 2 Color Conversion Figure 3 Low Voltage Wiring Wire Size 18 AWG 16 AWG ON OFF ae LED E 12 AWG Max Distance 500 150 m 825 250 m 1300 400 m 2100 650 m TABLE 1 TABLE 2 Cat No ISD BC 120 277V For use with Cat No ISD BC 120 277V For use with OSRAM Sylvania Advance Transformer 120 277V Mark VII Quicktronic 120 277V Helios Electronic Ballasts Advance OSRAM Sylvania Max Ballasts Dimmer for Multi gang
8. S CONTACT LITHONIA CONTROL SYSTEMS AT 1 800 533 2719 WARNING TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT IN FLUORESCENT LIGHTING APPLICATIONS USE ONLY WITH THE ADVANCE TRANSFORMER 120 277V MARK VII OR OSRAM SYLVANIA QUICKTRONIC HELIOS ELECTRONIC BALLASTS FOR CONTROLLING THE SPECIFIC FLUORESCENT LAMPS OTHER CAUTIONS 1 USE ONLY ONE 1 DIMMER IN A 3 WAY CIRCUIT THE SWITCH ES WILL TURN THE LIGHT ON AT THE BRIGHTNESS LEVEL SELECTED AT THE DIMMER 2 LIGHTING FIXTURE AND DIMMER MUST BE GROUNDED 3 DISCONNECT POWER WHEN SERVICING OR CHANGING LAMPS 4 USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO ALR OR CU AL MULTI GANG INSTALLATION When ganging dimmers the side sections of the mounting strap must be removed Use pliers to carefully bend side sections back and forth until they break off see Chart and Figure 1 MAXIMUM LOAD PER DIMMER FOR MULTI GANG Two More than Volts Gang 2 Gang ISD BC 120 1200 VA 1200 VA 1200 VA ISD BC 277 1500 VA 1500 VA 1500 VA MAXIMUM BULB WATTAGE IF USING WITH FLUORESCENT FIXTURES Mark VII and OSRAM Sylvania Quicktronic Helios ballast are rated in Volt Amps VA The maximum number of ballast per dimmer is based on the load VA rating see Maximum Load per Dimmer table or 50 ballast maximum which ever is less The maximum bulb wattage is determined by the efficiency of the ballast The following tables s
9. how the maximum number of ballasts that can be connected to a single dimmer for different Mark VII OSRAM Sylvania Quicktronic Helios ballasts FOR FOR DIRECT LOAD APPLICATION CONFIGURATIONS WIRING DIAGRAMS 1 2 AND 3 REFER TO TABLE 1 AND TABLE 2 FOR BALLAST INFORMATION NOTE For additional switching capacity up to 50 ballast use dimmers in conjuction with a Lithonia LPCS 120 277V remote power control station FOR APPLICATIONS USING LITHONIA S LPCS WIRING DIAGRAMS 4 AND 5 LPCS SWITCH RATINGS ARE AS FOLLOWS REFER TO LPCS INSTRUCTION SHEET FOR ADDITIONAL INFORMATION LPCS SWITCH RATINGS 20 Amps for 120 and 277 VAC Ballast TO INSTALL 1 WARNING TO AVOID FIRE SHOCK OR DEATH TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING 2 Remove existing wallplate and switch if applicable 3 Remove 3 4 1 9 cm of insulation from each circuit conductor Make sure the ends of wires are straight 4 Connect wires per appropriate WIRING DIAGRAM and FIGURE 3 as follows NOTE Common terminal of 3 Way Switch is usually labeled and or BLACK Twist strands of each lead tightly and with circuit conductors push firmly into appropriate wire connector Screw connectors on clockwise making sure no bare wires show below the wire connectors Secure each connector with electrical tape NOTE For single pole applications cap one BLACK lead with an appropriate size wire connector Secure connector with electrical tape
Download Pdf Manuals
Related Search
Related Contents
Mellanox MLNX-OS® Release Notes for IBM SX90Y3452 La réfraction - Réfraction œil Fiche technique CT 27.51 Tripp Lite Cat5e, 2.13m MDSTM Orbit MCR-3G - GE Digital Energy 9390 User guide - HF Boletim Técnico - TDN Triarch 60162 User's Manual Télécharger - le Grand Dijon Copyright © All rights reserved.
Failed to retrieve file